ICU Medical 80411396001 User Manual

HOSPIRA, INC., LAKE FOREST, IL 60045, USA
430-95597-004, B (Rev. 04/2007)
Plum A+® Infusion Systems
SECTION 1
NOTE: In this manual, references to Plum A+® Infusion System apply to both the Plum A+
Infuser unless otherwise noted.
Plum A+® Infuser List # 20679/20792­04
NOTE: This operating
manual may also be used with Device List # 12391-04 & 11971-04 when used with Module List # 20677-04.
®
Infuser and Plum A+®3
Plum A+®3 Infuser List # 20678-04
CAUTION: THIS
IS TO BE USED
DEVICE
AN IV POLE WITH A
WITH
6-WHEEL BASE AND A
.
SHELF
System Operating Manual 7
For Systems With Hospira MedNet
The Plum A+ and Plum A+3 Volumetric Infusion Systems are designed to meet the fluid delivery requirements of today’s evolving healthcare environments. Both are cassette based multi-function infusion systems. The Plum A+ allows two lines in and one line out while the Plum A+3 allows six lines in and three lines out. Each pump can be used for standard, piggyback, or concurrent delivery. Delivery modes include:
• Standard Infusions • Loading Dose
• Multistep Programming • Dose Calculation
The Plum A+ and Plum A+3 are designed to deliver parenteral, enteral, or epidural infusions over a broad range of infusion rates from multiple fluid container types.
Both are designed to be used in most areas of patient care, including, but not limited to:
®
Software
• General Floor • Labor/Delivery/ Post Partum
• Medical/Surgical • OR/Anesthesia • Hemodialysis
• ICU/CCU • Post Op/Recovery • Oncology
• Pediatrics • Cardiac Cath Lab • Mobile Intensive
• Neonatology • Emergency • Nutritional
• Burn Unit
Care
Product Description
Each system includes a pumping module (hereafter called the infuser) and an assortment of disposable IV sets (hereafter called a set), optional accessories, and this operator’s manual.
The Plum A+ host device contains a Connectivity Engine peripheral module that provides wired Ethernet and wireless
802.11 a/b/g local area networking capabilities. This allows the Hospira Mednet
drug libraries to the infuser and enable the auto-programming feature.
®
networked application software to download
8 System Operating Manual
Plum A+® Infusion Systems
Accessory equipment connected to the analog and digital interfaces must be certified according to the respective IEC Standards (e.g. IEC 60950 for data processing equipment and IEC 60601-1 for Medical Equipment). Furthermore, all configurations shall comply with the system standard IEC 60601-1-1. Any person who connects additional equipment to the signal input or output part configures a medical system, and is therefore responsible for ensuring that the system complies with the requirements of the system Standard IEC 60601-1-1. If in doubt, consult the technical service department or your local representative.
Indications for Use
USER QUALIFICATION
The Plum A+ is intended for use at the direction or under the supervision of licensed physicians or certified healthcare professionals who are trained in the use of the infuser and the administration of parenteral, enteral, and epidural fluids and drugs and whole blood or red blood cell components. The training should emphasize preventing related IV complications, including appropriate precautions to prevent accidental infusion of air. The epidural route can be used to provide anesthesia or analgesia.
WARNING
ADMINISTER ONLY ANESTHETICS/ANALGESICS APPROVED FOR EPIDURAL ADMINISTRATION (AS INDICATED OR ALLOWED BY THE DRUGS’ FDA APPROVED LABELING). EPIDURAL ADMINISTRATION OF DRUGS OTHER THAN THOSE INDICATED FOR EPIDURAL USE COULD RESULT IN SERIOUS INJURY TO THE PATIENT.
System Operating Manual 9
For Systems With Hospira MedNet
Conventions
This section describes the conventions used throughout this manual, as follows:
CONVENTION APPLICATION EXAMPLE
®
Software
Italic Reference to a
section, figure, or table
Function or mode specific instructions
[BRACKETED ALL CAPS]
[Italic] Softkey Options
Initial Caps lowercase
Bold Emphasis ...sets are supplied
Keys or buttons on the device are displayed in [BRACKETED ALL CAPS] or with a graphic.
Screen displays and device labels (as appropriate)
(See Figure 3-1,
Priming Cassette) Primary Only:
Attach an empty container.
[START]
or
[Choose]
Program Dose Calculation
Sterile and are
for....
WARNINGS, CAUTIONS, AND NOTES
Alert messages used throughout this manual are described below. Pay particular attention to these messages.
WARNING
A WARNING MESSAGE CONTAINS SPECIAL SAFETY EMPHASIS AND MUST BE OBSERVED AT ALL TIMES. FAILURE TO OBSERVE A WARNING MESSAGE IS POTENTIALLY LIFE THREATENING.
10 System Operating Manual
Plum A+® Infusion Systems
CAUTION: A CAUTION USUALLY APPEARS IN FRONT OF A
PROCEDURE COULD FAILURE SERIOUS
NOTE: A Note highlights information that helps explain a
concept or procedure.
NOTE: Figures are rendered as graphic representations to approximate the actual product. Therefore, figures may not exactly reflect the product.
OR STATEMENT. IT CONTAINS INFORMATION THAT
PREVENT IRREVERSIBLE PRODUCT DAMAGE OR HARDWARE
. FAILURE TO OBSERVE A CAUTION COULD RESULT IN
PATIENT OR USER INJURY.
This symbol directs the user to consult accompanying documents. When visible on the display, this symbol informs the user to use CAUTION because the specified drug has NOT been programmed with specified safety limits.
Precautions
The Plum A+ has been designed and manufactured to be safe, reliable, and easy to use. This section details precautions and possible hazards.
For safe operation of the Plum A+, observe the following precautions and hazards.
HEALTHCARE PROFESSIONALS AND PATIENT RELATED
• In vitro studies have suggested that packed red blood cells with unusually high hematocrit be diluted with blood­compatible fluids, such as 0.9% sodium chloride injection, to decrease hemolysis and increase flow rate.
• Setting the primary rate greater than the secondary rate will result in a more rapid infusion of any residual secondary drug remaining in the line and the cassette.
• Consult drug labeling to confirm drug compatibility, concentration, delivery rates, and volumes are all suitable for secondary, concurrent and piggyback delivery modes.