can accept most standard differential input levels.The
ICS85311 is characterized to operate from either a 2.5V
or a 3.3V power supply. Guaranteed output and partto-part skew characteristics make the ICS85311 ideal
for those clock distribution applications demanding well
defined performance and repeatability.
The ICS85311 is a low skew, high performance 1-to-2 Differential-to-2.5V/3.3V ECL/
LVPECL Fanout Buffer and a member of the
HiPerClockS™ family of High Performance
Clock Solutions from ICS. The CLK, nCLK pair
FEATURES
• 2 differential 2.5V/3.3V LVPECL / ECL outputs
• 1 CLK, nCLK input pair
• CLK, nCLK pair can accept the following differential input
levels: LVDS, L VPECL, L VHSTL, SSTL, HCSL
• Maximum output frequency up to 1GHz
• Translates any single ended input signal to 3.3V L VPECL
levels with resistor bias on nCLK input
• Output skew: 15ps (maximum)
• Part-to-part skew: 100ps (maximum)
• Propagation delay: 1.4ns (maximum)
• LVPECL mode operating voltage supply range:
= 2.375V to 3.465V , VEE = 0V
V
CC
• ECL mode operating voltage supply range:
VCC = 0V , VEE = -2.375V to -3.465V
• 0°C to 70°C ambient operating temperature
• Industrial temperature information available upon request
BLOCK DIAGRAMPIN ASSIGNMENT
CLK
nCLK
Q0
nQ0
Q1
nQ1
3.90mm x 4.90mm x 1.37mm package body
Q0
nQ0
Q1
nQ1
1
8
2
7
3
6
4
5
ICS85311
8-Lead SOIC
M Package
T op View
Vcc
CLK
nCLK
VEE
ICS85311AMwww.icst.com/products/hiperclocks.htmlREV. A JUNE 29, 2001
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These ratings
are stress specifications only. Functional operation of product at these conditions or any conditions beyond those listed in
DC Characteristics
the
or
AC Characteristics
periods may affect product reliability .
4.6V
-0.5V to VCC + 0.5V
-0.5V to VCC + 0.5V
112°C/W
-65°C to 150°C
is not implied. Exposure to absolute maximum rating conditions for extended