IC Realtime ICIPP3020HD User Manual

IR Speed Dome Installation Manual
Version 2.0
Table of Contents
1 IR SPEED DOME INSTALLATION .....................................................................8
1.1 Installation Preparation .........................................................................................................................8
1.2 IR speed dome and network IR speed dome installation ................................................................9
1.3 Initial Setup...........................................................................................................................................12
1.4 Dial Switch Setup.................................................................................................................................12
2 BRACKET DIMENSIONS .................................................................................15
2.1 Wall mount bracket..............................................................................................................................15
2.2 Hanging mount bracket (Multiple Lengths)......................................................................................15
2.3 Corner mount bracket .........................................................................................................................16
2.4 Pole mount bracket .............................................................................................................................16
3 WALL MOUNT BRACKET INSTALLATION......................................................17
3.1 Component Installation .......................................................................................................................17
2
3.2 Installation.............................................................................................................................................17
4 HANG MOUNT BRACKET INSTALLATION .....................................................19
4.1 Component Installation .......................................................................................................................19
4.2 Installation.............................................................................................................................................19
5 CORNER MOUNT BRACKET INSTALLATION ................................................21
5.1 Component Installation .......................................................................................................................21
5.2 Installation.............................................................................................................................................21
6 POLE MOUNT BRACKET INSTALLATION ...................................................... 23
6.1 Installation.............................................................................................................................................23
7 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION .......................25
8 APPENDIX Ⅱ ABOUT RS485 BUS ...................................................................26
8.1 RS485 Bus Main Feature ...................................................................................................................26
8.2 RS485 Bus Transmission Distance ..................................................................................................26
3
8.3 The Problem in Practical Use ............................................................................................................26
8.4 RS485 Bus FAQ ..................................................................................................................................27
9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE
DIAMETER AND THE TRANSMISSION DISTANCE...............................................28
10 APPENDIX IV WIRE GAUGE REFERENCE SHEET .......................................29
4
Welcome
Thank you for purchasing our speed dome!
Please read the following safeguards and warnings carefully before you install or use the product!
5
Important Safeguards and Warnings Safety Measures
Qualified Engineer Needed
z The installation engineer or maintenance engineer shall have corresponding CCTV system
installation certificate or maintenance qualification certificate.
z The installation engineer or maintenance engineer shall have qualification certificate for work
at height.
z The installation engineer or maintenance engineer shall have the basic knowledge and
operation technique for low-voltage cable layout and low-voltage electronic cable connection.
z Please read the installation manual carefully and keep it well for future reference,
z We are not liable for any problems caused by unauthorized modifications or attempted repair.
Lifting Appliance Requirement
z Please select the proper speed dome installation mode and use the lifting appliances at the
safety environment.
z The lifting appliances shall have the enough capacity to reach the installation height.
z The lifting appliances shall have safe performance.
Precautions
Safety Transportation
z Heavy stress, violent vibration or water splash are not allowed during transportation, storage
and installation.
z This series product must use split type package during the transportation.
z We are not liable for any damage or problem resulting from the integrated package during
the transportation.
When device is malfunction
Shut down the device and disconnect the power cable immediately if there is smoke, abnormal smell or abnormal function. Please contact your local retailer ASAP.
Do not try to dismantle or modify the device
z There is risk of personal injury or device damage resulting from opening the shell. z Please contact your local retailer if there is internal setup or maintenance requirement.
6
z We are not liable for any problems caused by unauthorized modifications or attempted repair.
Do not allow other object falling into the device
z Please make sure there is no metal or inflammable, explosive substance in the speed dome. z The above mentioned objects in the device may result in fire, short-circuit or damage. z Please shut down the device and disconnect the power cable if there is water or liquid falling
into the camera. Please contact your local retailer ASAP.
z Please pay attention to the camera. Avoid the sea water or rain to erode the camera.
Handle carefully
Do not allow this series product fall down to the ground. Avoid heavy vibration.
Installation Environment Requirement
z This series speed dome should be installed in a cool, dry place away from direct sunlight,
inflammable, explosive substances and etc.
z This series product shall be away from the strong electromagnetism radiant, please keep it
away from wireless power, TV transmitter, transformer and etc.
Daily Maintenance
z Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning
liquid to clean the shell and then use soft cloth to make it dry.
z Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result
in shell transfiguration or paint flake.
z Do not allow the plastic or rubber material to touch the shell for a long time. It may result in
paint flake.
7
1 IR SPEED DOME INSTALLATION
1.1 Installation Preparation
Basic Requirement
z All installation and operation here should conform to your local electrical safety codes. z Before installation, please open the package and check all the components are included.
Please make sure the speed dome installation environment and installation mode can meet your requirement. If there is special requirement, please contact your local retailer for more information.
z We assume no liability or responsibility for all the fires or electrical shock caused by
improper handling or installation.
Check installation space and installation location intension
Please make sure the installation environment has enough space to install the speed dome and its corresponding bracket. Please make sure the ceiling, wall and the bracket can support the speed dome and its corresponding installation component. The safety factor shall be 4X.
About cable
Please select the cable according to your transmission distance. The minimum video coaxial-cable requirement is:
z 75 ohm. z Full cable with copper conductor
z 95% knitted copper shield
International Model Max Distance
(Ft\M)
RG59/U 750ft (229m) RG6/U 1,000ft (305m) RG11/U 1,500ft (457m)
Set dial switch button
Set dial switch button according to control protocol and speed dome address. (Please refer to user’s manual for detailed information.)
Please keep all package material well for future use
Please keep speed dome package material well in case you need to send it back to your local retailer or manufacturer for maintenance work. Non-original package material may result in device damage during the transportation.
Check Accessories
Before the installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are includes.
8
1.2 IR speed dome and network IR speed dome installation
1.2.1 Speed dome bracket installation
The speed dome has several types of installation brackets. You can refer to the following contents for detailed information. Here we are going to install the IR speed dome in wall mount bracket.
1.2.2 Pipe thread bracket installation
Please connect the quick installation port to the wall mount bracket (Pipe thread connection) and then use the M4 stainless steel bolt to fix securely. Then you can connect the integrated cable to the composite cable of the flanges. Please connect the corresponding power cable, video output cable; RS 485 control cable, network cable, alarm input and output cable respectively (Please connect as your actual requirements). Finally, you can connect the flange to the quick installation
port. See Figure
Please note the analog speed dome does not have the network cable connection. You can connect the RS485, video output cable if necessary..
1-1.
Wall mount bracket
M4 bolt
Quick installation port
Flange
Waterproof composite cable
Flange Installation Speed Dome
9
Loading...