ICRealtime AVS-Z230IR User Manual

IR Intelligent Speed Dome Installation Manual
Version 1.0
Table of Contents
1 IR INTELLIGENT SPEED DOME INSTALLATION .............................................1
1.1 Installation Preparation .........................................................................................................................1
1.2 Initial Setup.............................................................................................................................................1
1.3 Dial Switch Setup (For Analog Speed Dome Only)..........................................................................1
1.4 Reset and SD card Installation (For IP Speed dome only) .............................................................3
1.5 Installation (For Analog and IP Speed Dome Both) .........................................................................3
2 HANG MOUNT INSTALLATION .........................................................................6
2.1 Installation Components .......................................................................................................................6
2.2 Installation...............................................................................................................................................6
3 CORNER MOUNT BRACKET ..........................................................................10
3.1 Component Installation .......................................................................................................................10
3.2 Installation.............................................................................................................................................10
i
4 POLE MOUNT BRACKET ................................................................................12
4.1 Installation.............................................................................................................................................12
5 BRACKET DIMENSIONS .................................................................................14
5.1 Wall Mount Bracket .............................................................................................................................14
5.2 Hanging Mount Bracket (Multiple Lengths) .....................................................................................14
5.3 Corner Mount Bracket.........................................................................................................................15
5.4 Pole mount bracket .............................................................................................................................15
6 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION .......................16
7 APPENDIX Ⅱ ABOUT RS485 BUS ...................................................................17
7.1 RS485 Bus Main Feature ...................................................................................................................17
7.2 RS485 Bus Transmission Distance ..................................................................................................17
7.3 The Problem in Practical Use ............................................................................................................17
7.4 RS485 Bus FAQ ..................................................................................................................................18
ii
8 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE
DIAMETER AND THE TRANSMISSION DISTANCE...............................................19
9 APPENDIX IV WIRE GAUGE REFERENCE SHEET .......................................20
10 APPENDIX V SAFETY ROPE INSTALLATION ................................................21
iii
Welcome
Thank you for purchasing our speed dome!
Please read the following safeguards and warnings carefully before you install or use the product!
iv
Important Safeguards and Warnings Safety Measures
Qualified Engineer Needed
z The installation engineer or maintenance engineer shall have corresponding CCTV system
installation certificate or maintenance qualification certificate.
z The installation engineer or maintenance engineer shall have qualification certificate for work
at height.
z The installation engineer or maintenance engineer shall have the basic knowledge and
operation technique for low-voltage cable layout and low-voltage electronic cable connection.
z Please read the installation manual carefully and keep it well for future reference,
z We are not liable for any problems caused by unauthorized modifications or attempted repair.
Lifting Appliance Requirement
z Please select the proper speed dome installation mode and use the lifting appliances at the
safety environment.
z The lifting appliances shall have the enough capacity to reach the installation height.
z The lifting appliances shall have safe performance.
Precautions
Safety Transportation
z Heavy stress, violent vibration or water splash are not allowed during transportation, storage
and installation.
z This series product must use split type package during the transportation.
z We are not liable for any damage or problem resulting from the integrated package during
the transportation.
About cable
Please select the cable according to your transmission distance.
The minimum video coaxial-cable requirement is:
z 75 ohm.
z Full cable with copper conductor
v
z 95% knitted copper shield
International Model Max Distance
(Ft\M)
RG59/U 750ft (229m) RG6/U 1,000ft (305m) RG11/U 1,500ft (457m)
Please keep all package material well for future use
Please keep speed dome package material well in case you need to send it back to your local
retailer or manufacturer for maintenance work.
Non-original package material may result in device damage during the transportation.
When device is malfunction
Shut down the device and disconnect the power cable immediately if there is smoke, abnormal
smell or abnormal function. Please contact your local retailer ASAP.
Do not try to dismantle or modify the device
z There is risk of personal injury or device damage resulting from opening the shell.
z Please contact your local retailer if there is internal setup or maintenance requirement.
z We are not liable for any problems caused by unauthorized modifications or attempted repair.
Do not allow other object falling into the device
z Please make sure there is no metal or inflammable, explosive substance in the speed dome.
z The above mentioned objects in the device may result in fire, short-circuit or damage.
z Please shut down the device and disconnect the power cable if there is water or liquid falling
into the camera. Please contact your local retailer ASAP.
z Please pay attention to the camera. Avoid the sea water or rain to erode the camera.
Handle carefully
Do not allow this series product fall down to the ground.
Avoid heavy vibration.
Installation Environment Requirement
z This series speed dome should be installed in a cool, dry place away from direct sunlight,
inflammable, explosive substances and etc.
z This series product shall be away from the strong electromagnetism radiant, please keep it
away from wireless power, TV transmitter, transformer and etc.
Daily Maintenance
z Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning
liquid to clean the shell and then use soft cloth to make it dry.
z Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result
in shell transfiguration or paint flake.
vi
z Do not allow the plastic or rubber material to touch the shell for a long time. It may result in
paint flake.
vii
1 IR INTELLIGENT SPEED DOME INSTALLATION
1.1 Installation Preparation
Basic Requirement
z All installation and operation here should conform to your local electrical safety codes.
z Before installation, please open the package and check all the components are included.
Please make sure the speed dome installation environment and installation mode can meet
your requirement. If there is special requirement, please contact your local retailer for more
information.
z We assume no liability or responsibility for all the fires or electrical shock caused by
improper handling or installation.
Check installation space and installation location intension
Please make sure the installation environment has enough space to install the speed dome and
its corresponding bracket.
Please make sure the ceiling, wall and the bracket can support the speed dome and its
corresponding installation component. It shall sustain the 4X weight of the speed dome.
1.2 Initial Setup
The default setup is:
z Address: 1
z Baud rate: 9600
z Parity: None.
1.3 Dial Switch Setup (For Analog Speed Dome Only)
1.3.1 Dial Switch
There are two dial switch buttons on the PCB of one side of the speed dome (There are labels.).
You can use them to set speed dome protocol, baud rate, address and etc. See Figure 1-1 . It is
1 when you set the button as ON.
For the protocol dial switch, you can refer to the following sheet. 1 is the lowest bit and the 8 is
the highest bit.
1 2 3 4 5 6 7 8 ON
NC
Please note the IR speed dome can automatically recognize the DH-SD, PELCO-D. PELCO­P. Usually you do not need to set the protocol.
120
Parity Baud rate
Connect to the 120
1
Loading...