ICP DAS USA MSM-508FC, MSM-508, MSM-508FCS User Manual

Page 1
TM
Managed Switch Console Manual
Industrial Managed Ethernet Switch
This document applied to models of
MSM-508,MSM-508FC/FCS/FT
©
Copyright
Release No. : 0804-V1
ICP DAS Co., Ltd., All Rights Reserved.
Page 2
CONTENTS
1. Console Connection........................................................................................2
2. Console Command .........................................................................................4
? [COMMAND] 4 REBOOTRESET 4 DEFAULT 5 IP 5 MASK 6 GATEWAY 6 MAC 6 NETID [id number] 7 LMASK [mask value] 8 CMASK [mask value] 9 SMASK [mask value] 9 LVALUE 10 CMASK 10 SMASK 11 HMIVALUE [value1] [value2] 11 RTIME [time] 12 FTIME [time] 13 MTIME [time] 13 HTIME [time] 14COM1 [baud rate][data bit][parity][stop bit] 15COM2 [baud rate][data bit][parity][stop bit] 16
Release No. : 0804-V1
Page 3
Industrial Redundant Ring Switch – Managed Switch Console Manual
Managed Switch
RS-232 & Telnet Console Operation
ICPDAS Managed Switch provides three access
Console Connection Console Command
methods, RS-232, Telnet and HTTP, to configure the Switch functions. This Manual will guide you how to use the RS-232 and Telnet to access Managed Switch console.
Release No. : 0804-V1 1
Page 4
Industrial Redundant Ring Switch – Managed Switch Console Manual
1. Console Connection
RS-232 Connection

ICPDAS RS Series Switch is shipped with a 9-pin Female D-sub & RJ-45 cable (CA-090510)please use this cable to connect Switch’s RS232 port with PC’s COM port.
You can connect to Switch console by using windows Terminal Emulator,
Baud Rate : 115200 Data Bits : 8 Parity : none Stop Bit : 1
Otherwise, you can download our free Console Emulator from RS Series Switch download page: http://www.icpdas.com/products/Switch/industrial/software.htm
Telnet Connection

Before using telnet to access console, please mask sure the PC host and Managed Switch are on the same subnet.
Factory default: IP Address : 192.168.255.1 Gateway : 192.168.0.1 Mask : 255.255.0.0
Otherwise, you have to change the network setting through the RS-232 connection.
STEP 1
Click windows [Start]  [Run] Type the Telnet command and switch’s IP address. EX: telnet 192.168.255.1
STEP 2
If connection succeeds, the login prompt will appear.
Release No. : 0804-V1 2
Page 5
Industrial Redundant Ring Switch – Managed Switch Console Manual
By factory default setting, both the account and password are Admin.
Only one telnet connection is accepted at the same time.
Release No. : 0804-V1 3
Page 6
Industrial Redundant Ring Switch – Managed Switch Console Manual
2. Console Command
? [COMMAND]
Description
Both “help” and “?” display a list of available commands, if parameter is not specified. The [command] parameter is used to see detail information for a specific command
Parameters
Parameter Description
command
Example
REBOOT////RESET
Please provide the name of the command that you want detail information about.
Description
The reset command will initiate Ring Switch a self-restart. All current setting values remain intact.
Release No. : 0804-V1 4
Page 7
Industrial Redundant Ring Switch – Managed Switch Console Manual
DEFAULT
Description
The default command will restore all settings to factory default values. Current factory default values are as follow:
COM1:baudrate 115200,8bit,none patity check, 1 stopbit COM2:baudrate 115200,8bit,none patity check, 1 stopbit link mask:0 communication mask:0x1f status mask:0x3 netid:1 mac: factory-set unique MAC address
Example
IP
Description
If no IP address is specified, the “ip” command will display current IP address. To assign an IP address for TCP/IP, please input IP address in the form of “ip1.ip2.ip3.ip4” (each field contains a value in the range 0 – 255).
ip:192.168.255.1 mask:255.255.255.0
Example
Release No. : 0804-V1 5
Page 8
Industrial Redundant Ring Switch – Managed Switch Console Manual
MASK
Description
If no mask address is specified, the “mask” command will display current mask address. To assign a mask address for TCP/IP, please input mask address in the form of “m1.m2.m3.m4” (each field contains a value in the range 0 – 255).
Example
GATEWAY
Description
If no gateway IP address is specified, the “gateway” command will display current gateway address. Note that if there exits a check sum error, an error message will alert. To assign a gateway address for TCP/IP, please input gateway IP address in the form of “ip1.ip2.ip3.ip4” (each field contains a value in the range 0 – 255).
Example
MAC
Description
If no MAC address is specified, the “mac” command will display current MAC address. To assign a MAC address for Ethernet, please input MAC address in the form of “e1:e2:e3:e4:e5:e6”.
Release No. : 0804-V1 6
Page 9
Industrial Redundant Ring Switch – Managed Switch Console Manual
Example
Each Switch is shipped from the factory with a unique MAC address, and the value is
labeled on the Switch case. DO NOT change this address unless you have a good reason to do so.
NETID [id number]
Description
If Net ID of Modbus is not specified, the “netid” command will display current ID number of Modbus. The command parameter [id number] is used to assign a specific ID number for Modbus Net ID.
Parameters
Parameter Description
id number Provides the ID number that you want to set up for Modbus Net ID.
Example
Release No. : 0804-V1 7
Page 10
Industrial Redundant Ring Switch – Managed Switch Console Manual
LMASK [mask value]
Description
This command enables you to configure relay output activation status when there is link loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0 corresponds to port 1, etc.
TABLE 1: Bits mapping Table
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port 8 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1
1 on 1 on 1 on 1 on 1 on 1 on 1 on 1 on 0 off 0 off 0 off 0 off 0 off 0 off 0 off 0 off
If the mask bit of that port(s) is specified by being set up as 1, when there is a link loss occurring on that port(s), relay output will be activated. The mask value is in hexadecimal format that represents the 8 bits corresponding binary numbers, it can be either in the form of initiating “0X” plus a suffix of the hexadecimal number or eliminating “0X”; simply the hexadecimal number itself. If a mask value is not specified, the “lmask” command will display previous assigned mask value.
Parameters
Parameter Description
mask value Provides the mask value that you want to specify to configure
status of relay when link loss occurs
Example
lmask 0x2d
Set Relay active if link lose on Port 1, 3, 4, or Port 6.
Release No. : 0804-V1 8
Page 11
Industrial Redundant Ring Switch – Managed Switch Console Manual
CMASK [mask value]
Description
This command enables you to configure relay output activation status when there is communication loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0 corresponds to port 1, etc.
The bits mapping please refer to TABLE 1. (LMASK command)
Example
cmask 0x1a
Set Relay active if communication lose on Port 2, 4, or port 6.
SMASK [mask value]
Description
This command enables you to configure relay output activation status when there is power fail occurring on power 1 or power 2, or when the switch is being selected as the master switch.
Bit 0 corresponds to Power1, bit 1 corresponds to Power 2 and bit 3 corresponds to master switch indicator. If the mask bit of that power(s)(bit 0 and bit 1) or master switch indicator (bit 2) is specified by being set up as 1, when there is a power fail occurring on Power(s), or when the switch is selected as master switch, the corresponding relay output will be activated.
Parameters
Parameter Description
mask value Provides the mask value that you want to specify for the
communication loss relay output
Example
smask 0x3
Release No. : 0804-V1 9
Page 12
Industrial Redundant Ring Switch – Managed Switch Console Manual
Set Relay active if Power 1 or Power 2 fail
LVALUE
Description
This command enables you to read link status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. Bit 0 corresponds to port 1, etc. If there is link loss occurring on port(s), the corresponding bit(s) will be set up as 1.
Example
Link loss occurring on port 2,3,4,5,6 and 8.
CMASK
Description
This command enables you to read ring pair communication status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. Bit 0 corresponds to port 1, etc.. If there is a communication loss occurring on port(s), the corresponding bit(s) will be set up as 1.
Example
Release No. : 0804-V1 10
Page 13
Industrial Redundant Ring Switch – Managed Switch Console Manual
SMASK
Description
This command enables you to read system status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers.
bit Corresponding to: Description
0 Power 1 If there is a power fail occurring on Power 1, bit 0 will be
set as 1.
1 Power 2 If there is a power fail occurring on Power 2, bit 1 will be
set as 1.
2 Master Ring Switch If his Switch is the master Ring Switch (the Master LED
indicator will be “on”) bit 2 will be set as 1.
3 Relay output status If the relay output is activated, bit 3 will be set as 1.
Example
Power2 fail occurring, and the Switch is the Master of the topology.
HMIVALUE [value1] [value2]
Description
This command enables you to configure the Switch operation modes.
Parameters
Parameter Description
Value 1 bit0 : set 1 to enable ring pair 1.
bit1 : set 1 to enable ring pair 2.
bit2 : set 1 to enable STP Protocol. otherwise is Cyber-Ring Protocol
bit3 : set 1 to force Switch as the Master of topology.
Value 2 Reserved.
Release No. : 0804-V1 11
Page 14
Industrial Redundant Ring Switch – Managed Switch Console Manual
Example
RTIME [time]
Description
Recovery time is the length of time it takes to return back to normal operation after an error or other failure has occurred. This command enables you to set up the recovery time in millisecond (ms).
Parameters
Parameter Description
time Provides the time interval(ms) that you want to set up as the
recovery time
Example
Return message: “recovery time X (Y) ms. ” “X” ( switch value) indicates the rtime value set by console command, “Y” (operating value) indicates the actual operating value. Value can be specified only on Cyber-Ring Protocol Mode (refer to HMIVLAUE setting).
NOTE
Use the following function to calculate an adequate rtime: rtime = [Round(0.3*(N+1))]*100 ms N: number of switches
Example: If there are 5 switches (including master switch), the adequate rtime will be:
Release No. : 0804-V1 12
Page 15
Industrial Redundant Ring Switch – Managed Switch Console Manual
[Round (0.3*(5+1))]*100 = Round (1.8) *100 =2*100 =200 ms
If the recovery time is not longer enough, the Master LED will keep on flashing to make
a warning.
FTIME [time]
Description
This command enables you to set up the spanning tree bridge forward delay in milliseconds (ms) . Forward delay is the time interval spent waiting to change a port from its spanning tree pre-forwarding state to a forwarding state. This is necessary because every bridge on the network should ensure no loop is formed before allowing the port to forward packets.
Parameters
Parameter Description
time Provides the time interval(ms) that you want to set up as the forward time
Example
Return message: “forward delay X (Y) ms. ” “X” ( switch value) indicates the ftime value set by console command, “Y” (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting).
MTIME [time]
Description
This command enables you to setup the spanning tree bridge maximum age in milliseconds (ms) . Max age is the maximum time a bridge waits without receiving spanning tree configuration messages before attempting a reconfiguration.
Release No. : 0804-V1 13
Page 16
Industrial Redundant Ring Switch – Managed Switch Console Manual
Parameters
Parameter Description
time Provides the time interval(ms) that you want to set up as the maximum time
Example
Return message: “max age time X (Y) ms. ” “X” ( switch value) indicates the mtime value set by console command, “Y” (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting).
HTIME [time]
Description
This command enables you to set the spanning tree bridge hello time in millisecond (ms). Hello time is the interval between transmissions of spanning tree configuration messages. All bridges send configuration messages during reconfiguration to select the designated root bridge (in this case, the switch port).
Parameters
Parameter Description
time Provides the time interval(ms) that you want to set up as the hello time
Example
Return message: “hello time X (Y) ms. ” “X” (switch value) indicates the htime value set by console command, “Y” (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting).
Release No. : 0804-V1 14
Page 17
Industrial Redundant Ring Switch – Managed Switch Console Manual
(0) , even (1), odd (2):, default value is 0.
▓▓▓▓
COM1 [baud rate][data bit][parity][stop bit]
Description
The first serial port
Com1 is assigned for RS232. This command enables you to set up the transmission speed (baud rate),data bit (data bit), parity check type (parity) and stop bit (stop bit).
The transmission speed parameter [baud rate] allows the following settings: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. The port speed and device speed must match.
The number of data bits can be 7 (for true ASCII) or 8 (for any kind of data, as this matches the size of a byte),
The parity check code can be set to none (0), even (1), or odd (2). None (0) means that no parity bit is sent at all. Even (1) means applying even parity check, each set of transmitted bits must have an even number of set bits. Odd (2) means applying odd parity check, each set of transmitted bits must have an odd number of set bits.
Stop bit is used in asynchronous communications to indicate the end of a piece of data.
Parameters
Parameter Description
baud rate Provides the baud rate (300 or 600 or 1200 or 2400 or 4800 or 9600 or 19200
or 38400 or 57600 or 115200)for your usage, default value is 115200
data bit Provides the data bit value(7 or 8), default value is 8
parity Provides the parity check type, none
stop bit Provides the stop bit (1 or 2), default value is 1.
Example
Release No. : 0804-V1 15
Page 18
Industrial Redundant Ring Switch – Managed Switch Console Manual
▓▓▓▓
COM2 [baud rate][data bit][parity][stop bit]
Description
The second serial port
the transmission speed (baud rate),data bit (data bit), parity check type (parity) and stop bit (stop bit).
Setting parameters are the same as COM1.
Com2 is assigned for RS485. This command enables you to set up
Release No. : 0804-V1 16
Loading...