The M-7053D offers 16 fully independent channels and 2 common ground channels for
digital input. The differential inputs feature channel-to-isolation. Communicable over
Modbus RTU, RS-485 and DCON protocol. It comes with free EZ Data Logger software
for PC based data logging and monitoring systems. Supports operating temperat ur es
between -25°C ~ +75°C (-13°F ~ +167°F). The ICP DAS M-7000 family of network data
acquisition and control modules support Modbus RTU. They can be remotely controlled
using a set of commands called DCON protocol. With the Modbus RTU protocol, it can
easily communicate with most popular SCADA/HMI software and PLCs.
2. Terminal Assignment
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
1
Page 2
3. Block/ Wiring Diagram
4. Default Settings
Default settings for the M-7053D module is:
。Protocol: Modbus RTU
。 Module Address: 01
。 DIO Type: Type 40
。 Baud Rate: 9600 bps
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
2
Page 3
5. Configuration
To install the module, follow the steps below:
1. Connect the thermistor analog input.
2. Connect the module to the RS-485 network using the DATA+ and DATA- terminals. If
the host is only equipped with an RS-232 interface, then an RS-232 to RS-485
converter will be required.
3. Connect the module to the power supply using the +Vs and GND terminals. Note that
the voltage supplied should be in the range of +10 to +30V DC.
4. Open DCON utility pro
click on COM port(first icon).
It can select multi-options such as Baud Rate, Protocol, Checksum, and Format to
search module. The default settings for the module can be found in Section 3. Click O K
after selecting the COM port setting.
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
3
Page 4
5. DCON utility pro will search for the selected COM port according the setting
previously set. DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS
and the others modules.
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
4
Page 5
6. Configuration I/O module setting on PC
7. For M-7000 modules using the Modbus RTU protocol, configure the module using the
following functions.
Sub-function 04h of Function 46h, see user manual Section 3.3.2
Sub-function 06h of Function 46h, see user manual Section 3.3.4
Sub-function 08h of Function 46h, see user manual Section 3.3.6
For M-7000 modules using the Modbus RTU protocol, use Function 04h to read the
data from the input channels. See user manual Section 3.2 for details.
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
5
Page 6
8.
If user doesn’t know command, user can select Address and ID, it will show some
refer commands as below. User can select necessary command to test or debug
modules.
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
6
Page 7
M-7053D 16 Channel DI DAQ Module - QuickStart (Feb/2017)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1 -310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
7