+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Industrial Quad-band GPRS/GSM Modem
GTM-201 Series
User Manual
Warranty
All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages consequent to the use of this product. ICP DAS reserves the right to change this manual at any time without notice. The information furnished by ICP DAS is believed to be accurate and reliable. However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third parties resulting from its use.
Copyright
Copyright 2009 by ICP DAS Co., LTD. All rights reserved worldwide.
Trademark
The names used for identification only may be registered
trademarks of their respective companies.
Publication Jul, 2013 Ver.
1.06
2
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Table of Contents
Chapter 1 Introduction .................................................... 3
Chapter 2 Hardware Specifications ............................... 4
2.1 GTM-201 Series ........................................................................ 4
2.2 GTM-201 Specifications ......................................................... 5
Chapter 3 Application architecture ................................ 7
3.1 Application 1.............................................................................. 7
3.2 Application 2.............................................................................. 7
3.3 Application 3.............................................................................. 8
3.4 Application 4.............................................................................. 8
Chapter 4 Hardware Appearance ................................... 9
4.1 View of the GTM-201-RS232 and GTM-201-USB Panel .. 9
4.2 Pin Assignments .................................................................... 10
4.3 Hardware Dimensions .......................................................... 11
4.4 LED indicators ........................................................................ 12
Chapter 5 Hardware Wire Connection ......................... 13
5.1 Reset Wire Connection ......................................................... 13
5.2 GSM/GPRS Installation ......................................................... 14
5.3 Quick Test ................................................................................ 15
Chapter 6 GPRS connection ......................................... 21
6.1 XPAC – 8000 (Microsoft Windows XP) ............................. 21
6.2 WinPAC-8000 (WinCE) .......................................................... 36
6.3 LinPAC – 8000 (Linux) .......................................................... 47
Chapter 7 USB driver installation ................................ 51
7.1 XPAC – 8000 (Microsoft Windows XP) ............................. 51
7.2 WinPAC – 8000 (WinCE) ....................................................... 59
7.3 LinPAC – 8000 (Linux) .......................................................... 60
Chapter 8 Software Reset ............................................. 61
8.1 Software Reset (for GTM-201-RS232) ............................... 61
Publication Jul, 2013 Ver.
1.06
3
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual

Chapter 1 Introduction

The GTM-201 series are industrial Quad-band GSM/GPRS modems with RS-232 and USB interfaces that work on frequencies of GSM 850 MHz, EGSM 900 MHz, DCS 1800 MHz and PCS 1900 MHz. The modems utilize the GSM/GPRS network for convenient and inexpensive data transfer from remote instruments, meters, computers or control systems in either live data or packet data. GTM-201 series have the integrated TCP/IP stack so that even simple controllers with serial communications ports can be connected to the modem without the need for special driver implementation. With the features of GTM-201 series, the systems can be SMS and GPRS connection applications with various PLC and PC. Moreover, with the voice interface, these modems can also be applied to the alarm system with sounds.
Publication Jul, 2013 Ver.
1.06
4
Model: GTM-201-RS232
Model: GTM-201-USB
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

Chapter 2 Hardware Specifications

2.1 GTM-201 Series

GTM-201 Series User Manual
Publication Jul, 2013 Ver.
1.06
5
Models
GTM-201-RS232
GTM-201-USB
GSM/GPRS System
GPRS/GSM Quad-band
850/900/1800/1900 MHz GPRS Multi-slot
Class 10/8
GPRS Mobile Station
Class B GPRS Class 10
Max. download speed 85.6 kbps
CSD
Up to 14.4 kbps
Compliant to GSM Phase 2/2+
Class 4 (2 W @ 850/900 MHz); Class 1 (1 W @ 1800/1900 MHz) Coding Schemes
CS 1, CS 2, CS 3, CS 4
SMS
Text and PDU Mode
Serial Ports
Serial Standards
RS-232 (DB9 Female)
USB (B-TYPE) to RS232(VCP)
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND
TxD, RxD, DTR, DSR, DCD, RI, GND
Baud Rate
9600 bps ~ 115200 bps
Include Cable
RS-232 9-Pin Female to Male cable(CA-0915)
USB Type A to Type B cable (CA-USB18)
Compatibility
-
USB 1.1 and 2.0 standard
USB Driver Support
-
 Windows 98 and 2000  Windows XP and XP 64-bit  Windows Vista and Vista 64-bit  WinPAC(WinCE 5.0)  LinPAC(Linux kernel 2.6)
Reset Input
Input Type
Isolated, 3750 V
rms
On Voltage Level
+3.5 VDC ~ +30 V
DC
Off Voltage Level
+1V max.
Input Impedance
3 kΩ, 0.25 W
LED Indicators
Power
Red color
GSM/GPRS
Green color
Power
Protection
Power reverse polarity protection
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

2.2 GTM-201 Specifications

GTM-201 Series User Manual
Publication Jul, 2013 Ver.
1.06
6
Frame Ground Protection
ESD, Surge, EFT, Hi-Pot
Required Supply Voltage
+10 VDC ~ +30 VDC
Power Consumption
Idle: 25 mA @ 24 VDC; Data Link: 100 ~ 400 mA (peak) @ 24 VDC Connection
5-Pin 3.81 mm Removable Terminal Block
Mechanical
Casing
Plastic
Flammability
UL 94V-0 materials
Dimensions (W x L x H)
33 mm x 87 mm x 107 mm Installation
DIN-Rail
Environment
Operating Temperature
-25 °C ~ +55 °C
Storage Temperature
-40 °C ~ +80 °C Humidity
5 ~ 95% RH, non-condensing
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Note1: The baud rate of GTM-201-RS232 and GTM-201-USB are default in
115200 bps.
Publication Jul, 2013 Ver.
1.06
7
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

Chapter 3 Application architecture

3.1 Application 1

GTM-201 Series User Manual

3.2 Application 2

Publication Jul, 2013 Ver.
1.06
8
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

3.3 Application 3

GTM-201 Series User Manual

3.4 Application 4

Publication Jul, 2013 Ver.
1.06
9
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual

Chapter 4 Hardware Appearance

4.1 View of the GTM-201-RS232 and GTM-201-USB Panel

GTM-201-RS232 :
GTM-201-USB :
Publication Jul, 2013 Ver.
1.06
10
RESET
RST+
RST-
Frame Ground
F.G.
Power Input: +10 ~ 30VDC
DC.GND
DC.+VS
SW1-Operation Mode
None
3-wire RS-232
RTS/CTS
Hardware Handshaking
9-wire RS-232
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

4.2 Pin Assignments

GTM-201 Series User Manual
Publication Jul, 2013 Ver.
1.06
11
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

4.3 Hardware Dimensions

GTM-201-RS232
GTM-201 Series User Manual
GTM-201-USB
Publication Jul, 2013 Ver.
1.06
12
Power normal
Power fail
Always on
Always off
Modem normal
Modem fail
Blanking (3 sec)
Off
or
Blanking (not 3 sec)
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual

4.4 LED indicators

There are two LED indicators to help users to judge the various conditions of GTM-201. The description is as follows
PWR(Red)The PWR LED can indicate the status of Power module.
GSM (Green)The modem LED can indicate the status of GSM module.
Publication Jul, 2013 Ver.
1.06
13
Input Type
Reset State ON
Reset State OFF
Reset
Input
Reset Input
ON Voltage Level
+3.5 VDC ~ +30 VDC
OFF Voltage Level
+1 VDC max.
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

Chapter 5 Hardware Wire Connection

5.1 Reset Wire Connection

Reset Wire Connection
GTM-201 Series User Manual
Timing of restart modem
Publication Jul, 2013 Ver.
1.06
14
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

5.2 GSM/GPRS Installation

SIM card Installation
GTM-201 Series User Manual
GPRS/GSM Antenna Installation
Publication Jul, 2013 Ver.
1.06
15
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

5.3 Quick Test

Hardware installation :
GTM-201 Series User Manual
Publication Jul, 2013 Ver.
1.06
16
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Software Installation: (Hyper Terminal)
Step1. Start All Programs Accessories Communications Hyper Terminal
Step2. If these is a pop-up form that Default Telent Program?, please select Yes
Publication Jul, 2013 Ver.
1.06
17
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step3. Input new connection name Click OK
GTM-201 Series User Manual
Step4. Select your PC serial port Click OK
Publication Jul, 2013 Ver.
1.06
18
Bits per second
115200
Data bits
8
Parity
None
Stop bits
1
Flow control
None (Note)
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step5. Please refer to the following settings
Note: Please select None mode on the GTM-201-RS232 SW1 Hardware
Step6. File Properties
Publication Jul, 2013 Ver.
1.06
19
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step7. Settings Click ASCII Setup…”
GTM-201 Series User Manual
Step8. Select Echo typed character locally OK
Publication Jul, 2013 Ver.
1.06
20
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step9. Input AT and press Enter, then you will receive AT OK
Publication Jul, 2013 Ver.
1.06
21

Chapter 6 GPRS connection

www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

6.1 XPAC – 8000 (Microsoft Windows XP)

6.1.1.1 GTM-201-RS232 Hardware requirement
1) GTM-201-RS232
2) XPAC-8000
3) RS-232 Cable
GTM-201 Series User Manual
6.1.1.2 GTM-201-USB Hardware requirement
1) GTM-201-USB (Please install USB driver first)
2) XPAC-8000
3) USB Cable
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
22
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.1.2.1 Create a new modem connection
Step1. Control Panel → Double-click Phone and Modem Options
Step2. Set the area code for the first time Click OK
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
23
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step3. Control Panel → Double-click Phone and Modem Options Modem Click
Add
Step4. Select “Don‟t detect my modem; I will select it from a list.” Click “Next”
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
24
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step5. Select Standard Modem Types → Select Standard 19200 bps Modem
Click Next
Step6. Select your COM Port to connect to the modem Click Next
Publication Jul, 2013 Ver.
1.06
25
Step7. Click Finish to finish the install new modem.
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step8. Control Panel → Double-click Phone and Modem Options Modem
Select Standard 19200 bps Modem Click Properties
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
26
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step9. Control Panel → Double-click Phone and Modem Options Modem
Select Standard 19200 bps Modem Click Properties Modem Maximum Port Speed 115200
Step10. Advanced Extra initialization commands:
Note: GPRSs APN must be provided from your Telecom. CO., LTD.
For example in Taiwan: AT+CGDCONT=1,IP,INTERNET For example in China: AT+CGDCONT=1,IP,CMNET
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
27
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step11. Diagnostics Query Modem Click OK
Note: If user queries modem that gets a Error, Please try again.
Step12. Click OK
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
28
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.1.2.2 Create a new dial-up and networking connection
Step1. Control Panel Network Connections Click Create a new connection
Step2. Click Next
Publication Jul, 2013 Ver.
1.06
29
Step3. Select Connect to the Internet Click Next
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step4. Select Connect using a dial-up modem Click Next
Publication Jul, 2013 Ver.
1.06
30
Step5. ISP Name Your GPRSs name Click Next
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step6. Phone Number: Click Next
Note: Phone Number must be provided from your Telecom. CO., LTD. For example in Taiwan: *99***1#
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
31
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step7. GPRSs User name and GPRSs Password Click Next
Note: GPRSs User name and GPRSs Password must be provided from your Telecom.
CO., LTD.
Step8. Click Finish
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
32
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step9. Contral Panel Network Connections Click Your GPRSs name
File Properties
Step10. General SelectStandard 19200 bps Modem Click Configure
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
33
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step11. Maximum speed(bps) Select ”115200” “Enable hardware flow control
(Note) → Click “OK”
Note1SW 1 on GTM-201-RS232 is RTS/CTS mode Please select Enable
hardware flow control
Note2GTM-201-USB Please dont select Enable hardware flow control
Publication Jul, 2013 Ver.
1.06
34
Step12. Click OK
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step13. Contral Panel Network Connections Double-Click Your GPRSs name
Publication Jul, 2013 Ver.
1.06
35
Step14. Click Dial
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step15. If you connect to internet successfully, your toolbar have new logo
Step16. You can Double-Click the new logo Click Details Get your IP address
Publication Jul, 2013 Ver.
1.06
36

6.2 WinPAC-8000 (WinCE)

www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.2.1.1 GTM-201-RS232 Hardware requirement
1) GTM-201-RS232
2) WinPAC-8000
3) RS-232 Cable
GTM-201 Series User Manual
6.2.1.2 GTM-201-USB Hardware requirement
1) GTM-201-USB (About install USB driver, please refer to the GTM-201-USB_Install_driver_manual. After finishing installing the driver, it will add a com port on WinPAC.)
2) WinPAC-8000
3) USB Cable
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
37
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.2.2.1 Create a new modem connection
Step1. Copy ICPDAS GTM-201-RS232_COM4_winpac.cab to your WinPAC
Double-Click ICPDAS GTM-201-RS232_COM4_winpac.cab to install Select OK
Step2. Execute “WinPAC_Utility File Save and Reboot
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
38
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.2.2.2 Create a new dial-up and newworking connection
Step1. Control Panel Double-Click Network and Dial-up Connections
Step2. Double-Click Make New Connection
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
39
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step3. Keyin your name for the connection Select Dial-Up Connection
Click Next
Step4. Select ICPDAS GTM-201-RS232 COM4: Click Configure…” Note: If your device is GTM-201-USB, please select ICPDAS GTM-201-USB COM5:
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
40
GTM-201-RS232 RTS/CTS mode
Please select Hardware
GTM-201-RS232 None mode
Please select None
GTM-201-USB
Please select None
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step5. Select Baud Rate 115200”, Data Bits 8, Parity None, Stop Bits “1 Note Click
Call Options
Note:
Step6. Extra Settings Click OK
Note: GPRSs APN must be provided from your Telecom. CO., LTD.
For example in Taiwan: +CGDCONT=1,IP,INTERNET
For example in China: +CGDCONT=1,IP,CMNET
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
41
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step7. Click TCP/IP Settings…”
Step8. TCP/IP Settings: Dependant on the requirement of each ISP.
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
42
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step9. Click Security Settings…”
Step10. Security Settings: Dependant on the requirement of ISP!Below picture is the
setting for HINET.
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
43
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step11. Click Next
Step12. Phone Number: Click Finish
Note: Phone Number must be provided from your Telecom. CO., LTD. For example in Taiwan: *99***1#
Publication Jul, 2013 Ver.
1.06
44
Step13. Double-Click you make new connection name
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step14. Click Dial Properties…”
Publication Jul, 2013 Ver.
1.06
45
Step15. Click Dialing Patterns…”
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step16. Keyin „G‟ to all blocks Click OK
GTM-201 Series User Manual
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
46
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step17. GPRS‟s User name and GPRSs Password Click Connect
Note: GPRSs User name and GPRSs Password must be provided from your Telecom.
CO., LTD.
Step18. If you connect to internet successfully, they will show Connected
Step19. Execute WinPAC_Utility File Save and Reboot
Publication Jul, 2013 Ver.
1.06
47

6.3 LinPAC – 8000 (Linux)

www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.3.1.1 GTM-201-RS232 Hardware requirement
1) GTM-201-RS232
2) LinPAC-8000
3) RS-232 Cable
GTM-201 Series User Manual
6.3.1.2 GTM-201-USB Hardware requirement
1) GTM-201-USB (Please install USB driver first)
2) LinPAC-8000
3) USB Cable
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
48
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
6.3.2.1 GTM-201-RS232
If users want to connect the gprs modem to the COM4 of LinPAC-8000, users should modify /etc/ppp/peers/wavecom to define COM port first. Please follow the steps as below :
(1) Type “ vi /etc/ppp/peers/wavecom ”
(2) To find the “Serial device to which the GPRS phone is connected:” statement, and
add device name of COM port.
Modify /etc/ppp/peers/wavecom
……
……
# Serial device to which the GPRS phone is connected:
# /dev/ttyS0 for serial port (COM1 in Windows),
# /dev/ircomm0 for IrDA,
# /dev/ttyUB0 for Bluetooth (Bluez with rfcomm running) and
# /dev/ttyUSB0 #for USB
/dev/ttyS34 # serial port one
# /dev/ttyS0 # serial port one
# /dev/ttyS1 # serial port two
……
……
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
49
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
(3) Type “ :wq “ to save and quit the script.
The default GPRS baudrate is “ 115200 ” in the LinPAC, so if users finish the setting of gprs modem and connect the gprs modem to the COM port of LinPAC-8000, just type in “ pppd call wavecom ” and then LinPAC-8000 will be connected to the internet automatically. Remember that the network interface card of LinPAC should stop first, just type in “ ifdown eth0 ” to stop it. If users type in “ ifconfig ” will see the “ ppp0 ” option.
6.3.2.2 GTM-201-USB
If users want to connect the gprs modem to the USB of LinPAC-8000, users should modify
/etc/ppp/peers/wavecom to defineUSB first. Please follow the steps as below :
(1) Type “ vi /etc/ppp/peers/wavecom ”
(2) To find the “Serial device to which the GPRS phone is connected:” statement, and
add device name of USB.
Modify /etc/ppp/peers/wavecom
……
……
# Serial device to which the GPRS phone is connected:
# /dev/ttyS0 for serial port (COM1 in Windows),
# /dev/ircomm0 for IrDA,
# /dev/ttyUB0 for Bluetooth (Bluez with rfcomm running) and
/dev/ttyUSB0 #for USB
#/dev/ttyS34 # serial port one
# /dev/ttyS0 # serial port one
# /dev/ttyS1 # serial port two
……
……
(3) Type “ :wq “ to save and quit the script.
The default GPRS baudrate is “ 115200 ” in the LinPAC, so if users finish the setting
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
50
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
of gprs modem and connect the gprs modem to the USB of LinPAC-8000, just type in “ pppd call wavecom ” and then LinPAC-8000 will be connected to the internet automatically. Remember that the network interface card of LinPAC should stop first, just type in “ ifdown eth0 ” to stop it. If users type in “ ifconfig ” will see the “ ppp0 ” option.
Remark: Please check O.S version. We have supported the GTM-201-USB module
after O.S version 1.2.
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
51
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

Chapter 7 USB driver installation

7.1 XPAC – 8000 (Microsoft Windows XP)

7.1.1 Automatically install usb driver Step1. Connect the GTM-201-USB and XPAC hardware with the USB cable, then power
on.
Step2. If pop up a new window that Found New Hardware Wizard, please select Cancel
Step3. Double-click GTM-201-USB driver that GTM-201-USB_v1.xx.exe.
Publication Jul, 2013 Ver.
1.06
52
Step4. Select Next
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step5. Select install folder Select Next
Publication Jul, 2013 Ver.
1.06
53
Step6. Select Install
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step7. If the installation process has popped up new window that Software Installation,
please select Continue Anyway
Publication Jul, 2013 Ver.
1.06
54
Step8. Select Finish
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step9. Please open Device Mansger check com port
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
55
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
7.1.2 Manually install usb driver Step1. Please install GTM-201-USB_v1.xx.exe first.
Step2. Connect the GTM-201-USB and XPAC hardward with usb cable , then power on
them.
Step3. Select No, not this time Select Next
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
56
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
Step4. Select Install from a list or specific location (Advanced) Select Next
Step5. Select Include this location in the search: Select Browse
Select C:\ICPDAS\GTM-201-USB Select OK
Publication Jul, 2013 Ver.
1.06
57
Step6. Select Next
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step7. If it is pop-up a new windows that Hardware Installation, please select
Continue Anyway”
Publication Jul, 2013 Ver.
1.06
58
Step8. Select Finish to finish the usb driver installation.
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Step9. Please open Device Mansger check com port
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
59
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

7.2 WinPAC – 8000 (WinCE)

Step1. Copy ICPDAS GTM-201-USB_COM5_WinPac.cab to your WinPAC
Double-Click ICPDAS GTM-201-USB_COM5_WinPac.cab to install Select OK
Step2. Execute “WinPAC_Utility File Save and Reboot
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
60
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

7.3 LinPAC – 8000 (Linux)

Please install usb driver first and follow the command as below:
Type insmod ftdi_sio
Remark: Please check O.S version. We have supported the GTM-201-USB module
after O.S version 1.2.
Publication Jul, 2013 Ver.
1.06
GTM-201 Series User Manual
61
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

Chapter 8 Software Reset

8.1 Software Reset

8.1.1 We Provide a Software Reset command for the user to reset the modem. Step1. Please open Hyper Terminal, and open the COM Port of the GTM-201.
Step2. type the command @ICPDASRESET, and then dont send any data to GSM
modem in 100ms. The modem will be reset.
Publication Jul, 2013 Ver.
1.06
62
Revised Note:
Version
By
Date
Description
1.00
Yide
2009/06/02
Release
1.01
Yide
2009/07/28
Release
1.0.2
Yide
2009/11/17
Modify
1.0.3
Yide
2009/12/31
Modify
1.04
Yide
2010/05/19
Modify
1.05
Malo
2012/3/27
Add chapter 8
1.06
Malo
2013/07/25
Add Soft Reset
Command for
GTM-201-USB
www.ipc2u.ru www.icp-das.ru
www.ipc2u.de www.ipc2u.com
ГК Атлант Инжинирингофициальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
GTM-201 Series User Manual
Publication Jul, 2013 Ver.
1.06
Loading...