1 Shipping Package
This shipping package contains the following items
1 x ECAT-2000 module 1 x Quick Start Guide (This Document)
2 Connecting the Power and Host device
Switch on module and connect it to an EtherCAT network
Connect the Host
device to the IN port on
ECAT-2000 module.
Connect the +Vs pin to positive
terminal on a 10 - 30 VDC power supply,
and connect the GND pin to the
negative terminal.

Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com 2
3 Search Modules
ESI file
The latest ESI file (ICPDAS ECAT-2000.xml) can be downloaded from ICP DAS website at
http://ftp.icpdas.com/pub/cd/fieldbus_cd/ethercat/slave/ecat-2000/software/
Install the ESI file
Copy the “ICPDAS ECAT-2000.xml” file to the Master Tools installation folder, as indicated in the table
below.
Beckhoff EtherCAT Configuration
C:\EtherCAT Configurator\EtherCAT
C:\TwinCAT\3.x\Config\Io\EtherCAT
Run the EtherCAT Master software (Beckhoff TwinCAT 2.X)
Switch on power
Execute the TwinCAT System Manager(Config mode)
I/O Devices-> Right click-> Scan Devices…
Click OK
Choose the correct network device which is
connected to ECAT-2000
Click Yes to start scanning and click Yes to
activate the free run mode for TwinCAT system
manager