ICPDAS ACS-11P-MF, ACS-10V-MF, ACS-11-MF Quick Start Manual

ACS-11P-MF Quick Start v1.0 2017/08
1/8
Quick Start
ACS-11P-MFPackage Checklist
The package includes the following items:
One ACS-11P-MF module One Quick Start One software utility CD Cables(CA-012x2, CA-013x1, CA-019x1, CA-020x1)
Note:
If any of these items are missed or damaged, contact the local distributors
for more information. Save the shipping materials and cartons in case you want to ship in the future.
Pin assignments
Table 1: Connector Pin Assignment
Connector Type
Pin Assignment
Description
CN1
(CA-019)
D+
D-
RS-485(D+/D-) Baud Rate (bps): 9600 Parity: NONE, Data Bits: 8, Stop Bits: 1
CN2
(CA-020)
DI0 G DI1
G
DI0(Door position detection) DI1(Electric lock trigger) (Digital Input, Dry Contact)
CN3
(CA-012)
NC
Electronic lock control (Relay Output)
COM
NO
CN4
(CA-012)
NC
Door position alarm output (Relay Output)
COM
NO
CN5
(CA-013)
COM
NO
NC
Anti-sabotage detection (Relay Output)
ACS-11P-MF Quick Start v1.0 2017/08
2/8
Hardware Installation
Figure 1: Wiring diagram
Figure 2: Wire connection
ACS-11P-MF Quick Start v1.0 2017/08
3/8
Software Installation
Before use, associated software configuration, the steps described as
follows
Connect to host PC, network and power supply
Figure 3: Host PC, Network and Power supply
01. Make sure that the network settings on the PC are properly configured and functioning properly
a. Entry the IP address as "192.168.0.x", where "x" is a number
Between 1 and 254 except 1, Subnet mask as "255.255.0.0". Finally, press "OK" button.
Figure 4: IP address configuration of Computer
02. Make sure that Windows Firewall or antivirus firewall is properly configured to allow incoming connections, or temporarily disable these features
Loading...