ICP H4H418GKD200, H4H419GKD100, T4H418GKD200, C4H419GKD100, T4H419GKD100 Technical Support Manual

...
TECHNICAL SUPPORT MANUAL
Split System Heat Pump
(C,H,T)4H4
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING, CAU­TION, and NOTE are used to identify levels of haz-
ard seriousness. The signal word DANGER is only used on product labels to signify an immediate haz­ard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and through­out this manual and other manuals that may apply to the product.
DANGER − Immediate hazards which will result in severe personal injury or death.
WARNING − Hazards or unsafe practices which could result in severe personal injury or death.
CAUTION − Hazards or unsafe practices which may result in minor personal injury or product or
property damage. NOTE − Used to highlight suggestions which will
result in enhanced installation, reliability, or opera­tion.
Signal Words in Manuals
The signal word WARNING is used throughout this manual in the following manner:
!
The signal word CAUTION is used throughout this manual in the following manner:
!
Signal Words on Product Labeling
Signal words are used in combination with colors and/or pictures on product labels.
WARNING
WARNING
CAUTION
TABLE OF CONTENTS
Wiring Diagrams 2 − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Charging Chart 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tech Labels (Expanded Data) 5 − 13. . . . . . . . . . . . . . . .
Cooling Multipying Factors 14 − 18. . . . . . . . . . . . . . . . . .
Heating Multipying Factors 19 − 24. . . . . . . . . . . . . . . . .
Model Number Identification 25. . . . . . . . . . . . . . . . . . . .
MODELS
C4H418GKD200 H4H418GKD200 T4H418GKD200 C4H419GKD100 H4H419GKD100 T4H419GKD100 C4H424GKD200 H4H424GKD200 T4H424GKD200 C4H430GKD200 H4H430GKD200 T4H430GKD200 C4H436GKD200 H4H436GKD200 T4H436GKD200 C4H442GKD200 H4H442GKD200 T4H442GKD200
C4H448GKD200 H4H448GKD200 T4H448GKD200 C4H460GKD300 H4H460GKD300 T4H460GKD300 C4H461GKD100 H4H461GKD100 T4H461GKD100
!
PERSONAL INJURY, AND/OR PROPERTY DAM­AGE HAZARD
Failure to carefully read and follow this warning could result in equipment malfunction, property damage, personal injury and/or death.
Installation or repairs made by unqualified per­sons could result in equipment malfunction, prop­erty damage, personal injury and/or death.
The information contained in this manual is in­tended for use by a qualified service technician fa­miliar with safety procedures and equipped with the proper tools and test instruments.
Installation must conform with local building codes and with the National Electrical Code NFPA70 current edition or Canadian Electrical Code Part 1 CSA C.22.1.
WARNING
428 04 5513 00 March 2010
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
2 428 04 5513 00
Model Sizes: 18, 19, 24, 30, 36, 42, 48, 60
330751−101_D
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
428 04 5513 00 3
Model Size: 61
330752−101_D
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
R−410A CHARGING CHART
Rating Plate (required) Subcooling Temperature ° F (° C)
Measured Liquid
Pressure (psig)
° F (° C) ° F (° C) ° F (° C) ° F (° C) F (° C) F (° C)
6 3 8 4 10 6 12 7 14 8 16 9
R−410A Required Liquid Line Temperature ° F (° C)
251 78 26 76 24 74 23 72 22 70 21 68 20 259 80 27 78 26 76 24 74 23 72 22 70 21 266 82 28 80 27 78 26 76 24 74 23 72 22 274 84 29 82 28 80 27 78 26 76 24 74 23 283 86 30 84 29 82 28 80 27 78 26 76 24 291 88 31 86 30 84 29 82 28 80 27 78 26 299 90 32 88 31 86 30 84 29 82 28 80 27 308 92 33 90 32 88 31 86 30 84 29 82 28 317 94 34 92 33 90 32 88 31 86 30 84 29 326 96 36 94 34 92 33 90 32 88 31 86 30 335 98 37 96 36 94 34 92 33 90 32 88 31 345 100 38 98 37 96 36 94 34 92 33 90 32 364 104 40 102 39 100 38 98 37 96 36 94 34 374 106 41 104 40 102 39 100 38 98 37 96 36 384 108 42 106 41 104 40 102 39 100 38 98 37 395 110 43 108 42 106 41 104 40 102 39 100 38 406 112 44 110 43 108 42 106 41 104 40 102 39 416 114 46 112 44 110 43 108 42 106 41 104 40 427 116 47 114 46 112 44 110 43 108 42 106 41 439 118 48 116 47 114 46 112 44 110 43 108 42 450 120 49 118 48 116 47 114 46 112 44 110 43 462 122 50 120 49 118 48 116 47 114 46 112 44 474 124 51 122 50 120 49 118 48 116 47 114 46
4 428 04 5513 00
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
428 04 5513 00 5
MULTIPLYING FACT ORS
(Refer to pages 6−12)
† Total capacities are net (I.D. blower heat subtracted) system capacities based on 25’ line set.
If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
†† At TVA rating indoor condition (75 °F db, 63 °F wb), all other indoor air temperatures are at 80 ° F db
If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. * System amps are total of indoor and outdoor amps. ‡ Chart data is for 80° F indoor dry bulb. For indoor db temperatures other than 80° F, measure Indoor db and Indoor CFM, and plug these into the
formula below. Measure outdoor db and indoor wet bulb, apply these to the chart above, find MBh and S/T, and plug these into the formula below. (Note: if indoor db is the only thing changing, total capacity, MBh, stays the same.)
Sensible Capacity at Indoor db LOWER than 80 ° F = ( MBh x S/T ) −
( 80 − Indoor db ) x 835 x Indoor CFM
1000
(
)
Sensible Capacity at Indoor db HIGHER than 80 ° F = ( MBh x S/T ) +
( Indoor db − 80 ) x 835 x Indoor CFM
1000
(
)
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
6 428 04 5513 00
COOLING
18 Size Outdoor With FEM4X18**** Indoor Cooling
Outdoor Ambient Temperature − Degrees F, Dry Bulb
75 85 95 105 115
Entering Indoor Temperature − Degrees F, Wet Bulb
CFM 72 67 63 62†† 57 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57
525
MBh21.03 19.06 17.66 17.31 16.70 20.03 18.13 16.79 16.45 16.02 18.98 17.16 15.86 15.56 15.30 17.86 16.12 14.92 14.64 14.54 16.67 15.02 13.85 13.72 13.72
S/T 0.51 0.68 0.71 0.89 1.00 0.51 0.70 0.72 0.91 1.00 0.52 0.71 0.74 0.94 1.00 0.53 0.73 0.76 0.96 1.00 0.54 0.76 0.79 1.00 1.00
AMPS* 0.05 0.05 0.05 0.05 0.05 0.06 0.06 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08
HI PR 263 261 260 259 259 305 302 301 300 300 350 348 346 346 345 400 398 396 396 396 456 454 452 452 452
LO PR 155 142 132 130 126 157 144 134 132 129 159 146 137 135 133 162 149 139 137 137 165 152 142 141 141
600
MBh21.49 19.49 18.06 17.73 17.41 20.45 18.52 17.15 16.86 16.69 19.36 17.50 16.19 15.95 15.94 18.20 16.43 15.17 15.13 15.13 16.97 15.28 14.09 14.26 14.26
S/T 0.52 0.71 0.74 0.93 1.00 0.53 0.73 0.75 0.95 1.00 0.54 0.74 0.77 1.00 1.00 0.55 0.77 0.80 1.00 1.00 0.56 0.79 0.82 1.00 1.00
AMPS* 0.05 0.05 0.05 0.05 0.05 0.06 0.06 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08
HI PR 264 262 260 260 260 305 303 301 301 301 351 348 347 346 346 401 399 397 397 397 456 454 452 453 453
LO PR 158 145 135 134 131 160 147 137 136 135 163 149 140 138 138 165 152 142 142 142 168 154 144 146 146
625
MBh21.62 19.60 18.17 17.86 17.63 20.57 18.62 17.25 16.99 16.90 19.46 17.60 16.28 16.12 16.12 18.29 16.51 15.25 15.30 15.30 17.05 15.35 14.16 14.42 14.42
S/T 0.52 0.72 0.75 0.94 1.00 0.53 0.74 0.77 0.96 1.00 0.54 0.76 0.78 1.00 1.00 0.55 0.78 0.81 1.00 1.00 0.57 0.81 0.84 1.00 1.00
AMPS* 0.05 0.05 0.05 0.05 0.05 0.06 0.06 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
HI PR 264 262 260 260 260 305 303 301 301 301 351 349 347 347 347 401 399 397 397 397 457 454 452 453 453
LO PR 159 146 136 135 133 161 148 138 137 136 163 150 140 140 140 166 153 143 143 143 168 155 145 148 148
HEATING
18 Size Outdoor With FEM4X18**** Indoor Heating
Outdoor Ambient Temperature − Degrees F, Dry Bulb
−3 7 17 27 37 47 57 67
Entering Indoor Temperature − Degrees F, Dry Bulb
CFM 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75
52
5
MBh 6.35 6.02 5.68 8.24 7.94 7.62 10.29 10.00 9.69 12.59 12.25 11.93 15.18 14.85 14.45 18.06 17.67 17.29 21.27 20.82 20.38 24.82 24.33 23.84
T/R 12.80 12.20 11.60 16.70 16.20 15.70 21.10 20.60 20.20 26.00 25.50 25.00 31.70 31.20 30.60 38.10 37.60 37.00 45.50 44.80 44.20 53.80 53.10 52.50
AMPS* 4.86 5.07 5.27 5.10 5.33 5.57 5.34 5.60 5.87 5.63 5.90 6.18 5.99 6.28 6.57 6.42 6.73 7.05 6.96 7.28 7.62 7.63 7.97 8.32
HI PR 232 248 264 247 264 281 265 282 301 287 305 323 314 333 352 348 367 388 388 409 430 436 458 480
LO PR 41 41 41 53 53 53 66 66 67 82 82 82 99 99 100 118 119 119 140 140 141 163 164 164
60
0
MBh 6.47 6.15 5.80 8.38 8.08 7.77 10.46 10.17 9.86 12.81 12.47 12.13 15.46 15.11 14.73 18.40 18.00 17.61 21.69 21.24 20.79 25.25 24.84 24.35
T/R 11.40 10.90 10.40 14.80 14.40 14.00 18.60 18.30 17.90 23.00 22.60 22.20 28.00 27.60 27.10 33.70 33.20 32.80 40.20 39.70 39.10 47.40 47.00 46.40
AMPS* 4.86 5.07 5.28 5.07 5.31 5.54 5.28 5.54 5.81 5.54 5.81 6.09 5.86 6.15 6.44 6.25 6.55 6.87 6.75 7.06 7.39 7.29 7.66 8.03
HI PR 228 243 260 241 258 275 257 275 293 277 295 313 303 321 340 333 352 372 371 391 411 411 434 458
LO PR 41 41 41 53 53 53 66 66 67 82 82 82 99 99 100 118 118 119 139 140 140 162 163 164
67
5
MBh 6.57 6.25 5.91 8.50 8.20 7.88 10.59 10.30 10.00 12.98 12.65 12.31 15.68 15.33 14.97 18.66 18.26 17.86 21.99 21.55 21.11 25.40 25.08 24.69
T/R 10.20 9.80 9.40 13.30 13.00 12.60 16.70 16.40 16.10 20.60 20.30 19.90 25.10 24.80 24.40 30.20 29.80 29.40 36.00 35.50 35.10 42.00 41.80 41.50
AMPS* 4.87 5.08 5.29 5.06 5.30 5.54 5.25 5.51 5.78 5.48 5.75 6.03 5.77 6.06 6.36 6.14 6.43 6.74 6.61 6.92 7.23 7.05 7.41 7.78
HI PR 224 240 257 237 254 271 251 269 287 270 288 306 294 312 331 323 341 361 358 378 398 393 415 438
LO PR 41 41 41 52 53 53 66 66 67 81 82 82 99 99 99 118 118 11 9 139 139 140 160 162 163
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
428 04 5513 00 7
COOLING
19 Size Outdoor With FEM4X18**** Indoor Cooling
Outdoor Ambient Temperature − Degrees F, Dry Bulb
75 85 95 105 115
Entering Indoor Temperature − Degrees F, Wet Bulb
CFM 72 67 63 62†† 57 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57
525
MBh† 21.45 19.37 17.89 17.51 16.75 20.42 18.43 17.02 16.66 16.10 19.32 17.43 16.09 15.77 15.40 18.18 16.38 15.10 14.82 14.65 16.96 15.27 14.06 13.87 13.84
S/T‡ 0.51 0.69 0.71 0.89 1.00 0.52 0.70 0.73 0.91 1.00 0.53 0.72 0.74 0.94 1.00 0.53 0.74 0.76 0.97 1.00 0.55 0.76 0.79 1.00 1.00
AMPS* 4.74 4.75 4.76 4.77 4.77 5.43 5.42 5.41 5.41 5.41 6.14 6.13 6.12 6.12 6.11 6.92 6.90 6.90 6.89 6.89 7.78 7.76 7.76 7.75 7.75
HI PR 265 262 260 259 258 307 304 302 301 300 353 351 349 348 347 404 401 400 399 399 459 456 454 454 454
LO PR 154 141 131 129 124 156 143 133 131 127 159 145 136 133 131 161 148 138 136 135 164 151 141 139 139
600
MBh† 21.96 19.84 18.33 17.97 17.53 20.87 18.85 17.41 17.09 16.83 19.73 17.80 16.44 16.18 16.08 18.53 16.71 15.41 15.30 15.27 17.27 15.54 14.33 14.44 14.42
S/T‡ 0.52 0.72 0.74 0.93 1.00 0.53 0.73 0.76 0.96 1.00 0.54 0.75 0.78 0.98 1.00 0.55 0.77 0.80 1.00 1.00 0.57 0.80 0.83 1.00 1.00
AMPS* 4.79 4.80 4.81 4.81 4.82 5.48 5.47 5.47 5.47 5.47 6.20 6.19 6.18 6.17 6.17 6.97 6.95 6.95 6.95 6.95 7.84 7.82 7.81 7.81 7.81
HI PR 266 263 261 260 259 308 305 303 302 302 354 352 350 349 349 404 402 400 400 400 460 457 455 455 455
LO PR 157 144 134 132 129 160 146 136 134 133 162 149 138 137 136 165 151 141 140 140 167 154 143 145 144
675
MBh† 22.36 20.20 18.67 18.37 18.19 21.22 19.17 17.72 17.48 17.45 20.03 18.08 16.70 16.67 16.65 18.80 16.95 15.65 15.82 15.80 17.49 15.76 14.53 14.92 14.90
S/T‡ 0.54 0.74 0.77 0.97 1.00 0.55 0.76 0.79 1.00 1.00 0.56 0.78 0.81 1.00 1.00 0.57 0.81 0.84 1.00 1.00 0.59 0.84 0.87 1.00 1.00
AMPS* 4.85 4.85 4.86 4.86 4.86 5.53 5.53 5.52 5.52 5.52 6.25 6.24 6.23 6.23 6.23 7.03 7.01 7.00 7.00 7.00 7.90 7.87 7.86 7.86 7.86
HI PR 266 263 261 261 261 308 306 303 303 303 354 352 350 350 350 405 402 401 401 401 460 457 455 456 456
LO PR 160 147 137 135 134 162 149 139 138 137 165 151 141 141 141 167 153 143 145 145 170 156 145 149 149
HEATING
19 Size Outdoor With FEM4X18**** Indoor Heating
Outdoor Ambient Temperature − Degrees F, Dry Bulb
−3 7 17 27 37 47 57 67
Entering Indoor Temperature − Degrees F, Dry Bulb
CFM 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75
525
MBh† 5.39 5.12 4.83 7.50 7.22 6.92 9.98 9.74 9.33 12.30 12.05 11.79 14.91 14.60 14.29 17.88 17.51 17.16 21.18 20.77 20.35 24.80 24.33 23.87
T/R 10.60 10.00 9.40 14.70 14.10 13.50 19.60 19.10 18.20 24.10 23.60 23.00 29.30 28.60 27.90 35.10 34.30 33.50 41.60 40.70 39.80 48.70 47.60 46.60
AMPS* 4.50 4.69 4.90 4.74 4.94 5.16 4.99 5.23 5.45 5.24 5.49 5.75 5.55 5.80 6.08 5.94 6.21 6.50 6.46 6.74 7.04 7.13 7.42 7.74
HI PR 223 238 254 239 255 272 259 276 293 280 297 316 305 323 341 336 354 373 373 392 411 418 438 458
LO PR 40 41 41 52 52 52 65 65 65 80 80 80 97 97 98 116 11 7 11 7 138 138 139 161 162 163
600
MBh† 5.47 5.21 4.92 7.61 7.34 7.04 10.10 9.88 9.62 12.46 12.21 11.95 15.13 14.82 14.50 18.17 17.80 17.43 21.55 21.12 20.70 25.23 24.76 24.29
T/R 9.40 8.90 8.40 13.10 12.60 12.00 17.30 16.90 16.40 21.40 20.90 20.40 26.00 25.40 24.80 31.20 30.50 29.80 37.00 36.20 35.40 43.30 42.40 41.50
AMPS* 4.51 4.70 4.91 4.72 4.93 5.15 4.95 5.19 5.43 5.17 5.42 5.68 5.45 5.71 5.97 5.81 6.08 6.36 6.30 6.57 6.87 6.94 7.23 7.53
HI PR 219 235 251 234 250 267 252 269 287 271 288 307 294 312 331 323 341 360 359 377 397 402 421 441
LO PR 40 40 41 52 52 52 65 65 65 80 80 80 97 97 97 116 11 7 11 7 137 138 138 161 161 162
675
MBh† 5.55 5.29 5.00 7.72 7.44 7.14 10.21 9.99 9.74 12.60 12.34 12.08 15.31 14.99 14.68 18.40 18.03 17.66 21.82 21.39 20.97 25.53 25.07 24.60
T/R 8.50 8.10 7.60 11.80 11.30 10.80 15.60 15.20 14.80 19.20 18.80 18.40 23.40 22.80 22.30 28.10 27.50 26.80 33.30 32.60 31.90 39.00 38.20 37.40
AMPS* 4.53 4.72 4.93 4.73 4.94 5.16 4.93 5.17 5.41 5.13 5.38 5.63 5.39 5.64 5.90 5.73 5.99 6.27 6.20 6.47 6.75 6.82 7.11 7.40
HI PR 217 233 249 230 247 263 247 264 282 264 282 300 286 304 322 314 332 350 349 367 386 390 409 429
LO PR 40 40 41 52 52 52 65 65 65 80 80 80 97 97 97 116 11 6 11 7 137 138 138 160 161 162
TECHNICAL SUPPORT MANUAL Split System Heat Pump: (H,C,T)4H4
8 428 04 5513 00
COOLING
24 Size Outdoor With FS(M,U)4X30**** Indoor Cooling
Outdoor Ambient Temperature − Degrees F, Dry Bulb
75 85 95 105 115
Entering Indoor Temperature − Degrees F, Wet Bulb
CFM 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57 72 67 63†† 62 57
70
0
MBh27.78 25.42 23.69 23.23 22.41 26.42 24.18 22.53 22.10 21.50 24.98 22.86 21.30 20.91 20.54 23.49 21.47 20.00 19.67 19.51 21.89 20.00 18.62 18.40 18.40
S/T 0.51 0.69 0.72 0.90 1.00 0.52 0.70 0.73 0.92 1.00 0.52 0.72 0.75 0.95 1.00 0.53 0.74 0.77 0.97 1.00 0.54 0.76 0.79 1.00 1.00
AMPS* 6.89 6.88 6.88 6.88 6.88 7.71 7.71 7.71 7.71 7.70 8.62 8.62 8.62 8.62 8.62 9.63 9.62 9.62 9.62 9.62 10.73 10.72 10.71 10.71 10.71
HI PR 256 254 252 252 251 296 294 292 292 291 341 338 336 336 335 389 386 384 384 383 442 439 437 437 436
LO PR 154 141 131 129 125 157 144 134 131 128 159 146 136 134 132 162 148 138 136 135 165 151 141 140 140
80
0
MBh28.25 25.87 24.13 23.71 23.27 26.84 24.57 22.92 22.55 22.31 25.35 23.20 21.64 21.34 21.28 23.78 21.76 20.29 20.18 20.19 22.13 20.24 18.86 19.00 19.00
S/T 0.52 0.72 0.75 0.95 1.00 0.53 0.74 0.76 0.97 1.00 0.54 0.76 0.78 0.99 1.00 0.55 0.78 0.80 1.00 1.00 0.57 0.81 0.83 1.00 1.00
AMPS* 7.04 7.04 7.03 7.03 7.03 7.86 7.86 7.86 7.86 7.86 8.77 8.77 8.77 8.77 8.77 9.78 9.77 9.77 9.77 9.77 10.88 10.87 10.87 10.86 10.87
HI PR 257 254 253 253 252 297 295 293 292 292 341 339 337 336 336 390 387 385 385 385 442 440 437 438 438
LO PR 158 145 135 133 130 160 147 137 135 134 162 149 139 137 137 165 151 141 141 141 167 154 143 145 145
90
0
MBh28.60 26.20 24.46 24.12 23.99 27.14 24.86 23.20 22.98 22.97 25.60 23.45 21.88 21.88 21.89 23.99 21.96 20.49 20.73 20.73 22.30 20.40 19.03 19.48 19.49
S/T 0.54 0.75 0.78 0.98 1.00 0.55 0.77 0.79 1.00 1.00 0.56 0.79 0.82 1.00 1.00 0.57 0.82 0.84 1.00 1.00 0.59 0.85 0.87 1.00 1.00
AMPS* 7.19 7.19 7.19 7.19 7.19 8.01 8.01 8.01 8.01 8.01 8.92 8.92 8.92 8.92 8.92 9.93 9.93 9.92 9.92 9.92 11.03 11.03 11.02 11.02 11.02
HI PR 257 255 253 253 253 297 295 293 293 293 342 339 337 337 337 390 387 385 386 386 443 440 438 439 439
LO PR 161 147 137 136 135 163 149 139 138 138 165 151 141 142 142 167 154 143 145 145 170 156 145 149 149
HEATING
24 Size Outdoor With FS(M,U)4X30**** Indoor Heating
Outdoor Ambient Temperature − Degrees F, Dry Bulb
−3 7 17 27 37 47 57 67
Entering Indoor Temperature − Degrees F, Dry Bulb
CFM 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75
70
0
MBh 9.03 8.66 8.25 11.51 11.17 10.81 14.16 13.84 13.50 17.15 16.78 16.39 20.52 20.11 19.71 24.13 23.77 23.36 27.24 27.06 26.79 30.45 30.49 30.15
T/R 14.00 13.50 13.00 17.90 17.60 17.10 22.30 21.90 21.60 27.20 26.80 26.40 32.90 32.50 32.10 39.10 38.80 38.50 44.60 44.70 44.60 50.30 50.90 50.70
AMPS* 6.26 6.51 6.76 6.61 6.90 7.20 6.96 7.29 7.63 7.39 7.74 8.09 7.91 8.28 8.67 8.43 8.85 9.28 8.95 9.41 9.87 9.52 10.05 10.53
HI PR 231 247 263 247 263 281 264 282 300 287 305 324 316 334 354 344 365 387 373 397 420 405 432 456
LO PR 39 39 39 50 50 51 63 64 64 78 78 79 95 95 95 112 11 3 11 4 127 129 131 142 146 147
80
0
MBh 9.22 8.85 8.45 11.72 11.39 11.02 14.40 14.08 13.74 17.45 17.07 16.69 20.87 20.47 20.06 24.24 24.00 23.69 27.28 27.03 26.85 28.82 29.28 29.62
T/R 12.50 12.10 11.60 15.90 15.60 15.20 19.70 19.40 19.10 24.10 23.80 23.40 29.10 28.70 28.40 34.10 34.00 33.90 38.60 38.60 38.70 41.00 42.10 43.00
AMPS* 6.33 6.59 6.85 6.65 6.95 7.25 6.97 7.30 7.63 7.36 7.70 8.05 7.83 8.20 8.58 8.25 8.67 9.09 8.72 9.14 9.61 8.92 9.50 10.08
HI PR 227 243 259 241 258 275 257 274 293 278 296 314 304 323 342 328 349 370 354 376 399 366 396 425
LO PR 39 39 39 50 50 51 63 63 64 78 78 79 94 95 95 111 11 2 11 3 125 126 128 132 137 141
90
0
MBh 9.40 9.03 8.62 11.90 11.57 11.22 14.62 14.28 13.95 17.73 17.32 16.94 21.15 20.75 20.35 24.25 24.05 23.83 26.58 27.01 26.79 27.42 28.01 28.52
T/R 11.30 10.90 10.50 14.30 14.10 13.70 17.70 17.50 17.20 21.70 21.30 21.00 26.00 25.80 25.50 30.10 30.10 30.10 33.10 34.00 34.10 34.30 35.40 36.40
AMPS* 6.42 6.69 6.94 6.71 7.01 7.32 7.00 7.33 7.67 7.37 7.71 8.06 7.79 8.17 8.55 8.17 8.57 8.99 8.49 9.01 9.45 8.57 9.12 9.69
HI PR 224 240 256 236 253 271 251 268 287 271 288 307 294 314 333 316 337 358 335 362 384 339 368 397
LO PR 39 39 39 50 50 51 63 63 64 78 78 78 94 95 95 109 11 0 11 2 119 124 126 123 128 134