ICP PGD536, PGS560, PGD524, PGD548, PG524040 Owner's Manual

...
Page 1
Packaged Gas Heat/Electric Cooling Units
Owner's Guide to Operating and
Maintaining Your Gas/Electric Unit
ELECTRICAL SHOCK HAZARD.
Failure to follow this warning could result in personal injury, death, and/or property damage.
Disconnect power at fuse box or service panel before performing recommended maintenance.
Failure to follow this warning could result in personal injury, death, and/or property damage.
Do not use this unit if any part has been under
water. Immediately call a qualified service technician to inspect the unit and to replace any
part of the control system which has been under
water.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, and/or property damage.
Information in this manual MUST be followed exactly.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Leave the building immediately.
Do not try to light any appliance.
Do touch any electrical switch; do not use any
phone in the building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
This manual should be left with the owner.
04/28/09 462 02 2102 00
Page 2
SAFETYCONSIDERATIONS
Improper installation, adjustment, alteration, service maintenance, or use can cause explosion, fire, electrical
shock, or other conditions which may cause death,
personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or
agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual
instructions packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective
clothing, and work gloves. Have a fire extinguisher available. Read these instructions thoroughly and follow
all warnings or cautions included in literature and attached to the unit. consult local building codes, the
current editions of the National Fuel Gas Code (NFGC)
NFPA 54/ANSI Z223.1, and the National Electrical Code (NEC) NFPA 70.
In Canada refer to the current editions of the National Standards of Canada CAN/CSA-B149.1 and .2 Natural Gas and Propane Installation codes, and Canadian
Electrical Code CSA C22.1
Recognize safety information. This is the safety-alert symbol /_. When you see this symbol on the unit and in
instructions or manuals, be alertto the potential for personal
injury. Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the
safety-alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe
practices which may result in minor personal injury or
product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation,
reliability, or operation.
Note: Installer: This manual should be left with the equipment user.
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Installation and servicing of this equipment can be hazardous due to mechanical and electrical
components. Only trained and qualified personnel should install, repair, or service this equipment.
CUT HAZARD
Failure to follow this warning could result in personal injury, or death.
When removing access panels or performing maintenance functions inside your unit, be aware of sharp
sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely
careful when handling parts or reaching into the unit.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
and/or death.
Before performing recommended maintenance, be sure the
main power switch to unit is turned off and lock-out tag is
installed.
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death and/or property damage.
1. Do not turn off the electrical power to unit without first
turning off the gas supply.
2. Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be
followed.
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
Do not attempt to light by hand.
UNIT INTRODUCTION
This unit is a small packaged gas heat/electric cooling system that can utilize the comfort of gas heating packaged
along with efficient electric air conditioning.
Starting or Shutting Unit Off:
Note: Your combination heating/cooling unit is equipped
with an automatic direct spark ignition and power combustion blower.
To Start Unit Gas Heat:
Refer to Figure 1 for location of unit access panel. Refer to Figure 2 for location of gas valve. Refer to Figure 3 while
proceeding with the following steps.
1. Set the temperature selector on room thermostat to the lowest temperature setting and set system switch to
HEAT.
2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the control access panel with a 5/16" nut driver. See Fig. 1.
5. Move the selector switch on the internal gas valve tothe OFF position and wait 5 minutes. See Fig. 2.
6. Move the selector switch on the internal gas valve tothe ON position.
7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.
10. Set the temperature selector on room thermostat slightly above room temperature to start unit. The
induced-draft combustion air fan will start. Main gas
valve will open and main burners should ignite within 5 seconds. If the burner does not light within 5 seconds,
Page 3
theignitionmodulewillgointoa RetryModeaftera
periodof approximately22seconds(followingthe5
secondignitionperiod).Iftheburnersdonotlightwithin
15minutesoftheinitialcallforheat,thereisalockout.
11.Setthetemperatureselectoronroomthermostatto desiredsetting.
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
1. If the main burners fail to light, or the blower fails to start, shut down gas heating section and call your dealer for
service.
2. Never attempt to manually light the main burners on unit with a match, lighter, or any other flame. If the electric sparking device fails to light the main burners, refer to the
following shutdown procedures, then call your dealer as
soon as possible.
FIGURE 1 J Unit Access Panels
Filter
Access
Panel
FIGURE 2 Access Panel Removed
Gas Heating / Electric Cooling Unit with
Flue Hood
Burners Gas Valve
To Shut Off Unit Gas Heat:
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
Do not turn off the electrical power to unit without first turning off the gas supply.
Note: If the unit is being shut down because of a malfunction, call your dealer as soon as possible.
Should overheating occur or the gas supply fail to shut off, shut off the manual gas valve to the unit before shutting off
the electrical supply. Do not use this unit ifany part has been
under water. Immediately call a qualified service technician
to inspect the unit and to replace any part of the control system and any gas control which has been under water.
Refer to Figure 4 while proceeding with the following steps.
1. Set the temperature selector on room thermostat to lowest temperature setting and set system switch to
OFF.
2. Close the external manual gas shutoff valve.
3. Turn off the electrical power supply to the unit.
4. Remove the control access panel. See Fig. 1.
5. Move the selector switch on the internal gas valve tothe
OFF position. See Fig. 2.
6. Replace the control access panel.
To Start Unit Electric Cooling:
Refer to Figure 5 while proceeding with the following steps.
1. Set the temperature selector on room thermostat to highest temperature setting and set system SWITCH to
OFF.
2. Close the external manual gas shutoff valve, if not
already closed.
3. Turn ON the electrical power supply to the unit.
4. Set system switch to COOL.
5. Set the temperature selector on room thermostat
slightly below the room temperature to start unit.
To Shut OFF Unit Electric Cooling:
Refer to Figure 6 while proceeding with the following steps.
1. Set the temperature selector on room thermostat to highest temperature setting and set system SWITCH to
OFF.
2. Close the external manual gas shutoff valve, if not
already closed.
3. Turn OFF the electrical power supply to the unit. OPERATING YOUR UNIT
The operation of your system is controlled by the indoor temperature control (Thermostat). Your gas heating /
electric cooling unit requires a thermostat with 2 stages of cooling and 1 stage of heating. You simply adjust the
thermostat and it maintains the indoor temperature at the
level you select. Most thermostats of heating and cooling
systems have 3 controls: a temperature control selector, a
FAN control, and a System or MODE control. Refer to your
thermostat owner's manual for more information.
Page 4
To better protectyour investmentand to eliminate
unnecessaryservicecalls,familiarizeyourselfwiththe
followingfacts:
Cooling Mode
With the SYSTEM or MODE control set to COOL, your unit will run in cooling mode until the indoor temperature is
lowered to the level you have selected. On extremely hot
days, your unit will run more often on the high capacity stage. On mild days, your unit will run more often on low capacity stage for even greater energy savings.
Gas Heating Mode
With the SYSTEM or MODE control of your indoor thermostat set to HEAT, your unit will run in heating mode
until the room temperature is raised to the level you have
selected. On cold days and nights, your system will typically
run for longer periods of time and have shorter "off" periods
than on moderate days.
MAINTENANCE AND SERVICE
This section discusses maintenance that should be
performed on your system. Most maintenance should be performed by your dealer. You, as the owner, may wish to
handle some minor maintenance for your new unit.
Routine Maintenance
All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish
a standard procedure.
For your safety, keep the unit area clear and free of
combustible materials, gasoline, and other flammable
liquids and vapors.
To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit.
Clearance from the top of the unit is 48" (1219 mm). Clearance of at least 36" (914 mm) is required on sides
except the power entryside (42" (1067 mm) clearance) and the duct side (12" (305 mm) clearance).
Maintenance and Care for the Equipment Owner Before proceeding with those things you might want to
maintain yourself, please carefully consider the following:
FIRE, EXPLOSION, ELECTRICAL SHOCK AND CUT HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
1. Turn off gas supply first, then all electrical power to your unit and install lock-out tag before servicing or per-
forming maintenance.
2. When removing access panels or performing maintenance functions inside your unit, be aware of
sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be
extremely careful when handling parts or reaching into the unit. Wear safety glasses, gloves, and appropriate
protective clothing.
Air Filters The air filter(s) should be checked every 3 or 4 weeks and
changed or cleaned whenever it becomes dirty. Dirty filters
produce excessive stress on the blower motor and can
cause the motor to overheat and shut down. This unit must have air filters in place before it can be
operated. These filters can be located inone of at least two
places. In many applications, the installer will provide return
air filter grilles mounted on the wall or ceiling of the conditioned structure. In the instance of filter grilles, the
filters can simply be removed from the grille and replaced. The other typical application is an accessory filter rack
installed inside the unit itself. The following information is
given to assist in changing filters used inthese internal filter
racks.
Table 1 indicates the minimum indoor filter size for your unit.
Table l--Indoor Air Filter Data
Return Air Filter Size
Unit Model
PG(D,S)524040 PG(D,S)524060
PG(D,S)536060
in,
20x20x1 20x24x1
24x30x1
mm
508x508x25 508x610x25
610x762x25
PG(D,S)536090 PG(D,S)548090
PG(D,S)548115 PG(D,S)548130
24x36x1
610x914x25
PG(D,S)560090 PG(D,S)560115
PG(D,S)560130
When installing the new filter(s), note the direction of the airflow arrows on the filter frame.
If you have difficulty locating your air filter(s) or have
questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always
use the same size and type of filter that was supplied,
originally, by the installer.
If using an Accessory Filter Rack, refer to the Installation
Instructions provided with it for correct filter sizes and quantities. Refer to Figure 1to access filters installed in the accessory filter rack.
To replace / inspect filters in accessory filter rack. See Figure 1
1. Remove the filter access panel using a 5/16" (8mm) nut driver.
2. Remove the filter(s) by pulling it out of the unit. If the filter(s) is dirty, clean or replace with a new one.
UNIT OPERATION HAZARD Failure to follow this caution could result in personal
injury, death or unit damage. Never operate your unit without filters in place. An
accumulation of dust and lint on internal parts of your unit can cause loss of efficiency.
Page 5
FIGURE 3 J To Start Unit Gas Heat
@
STEP1 STEP 2
MAIN
O_,
,,1,-.-..-
STEP 3
STEP6
MAIN
STEP4 STEP 5
STEP 7
I
STEP 8
STEP 9
STEP 10
12
Page 6
FIGURE 4 ] To Shut OFF Unit Gas Heat
MAIN
!
l
° !
STEP1
1
STEP 4
STEP2
STEP 3
STEP 5
STEP 6
161
Page 7
FIGURE 5 J To Start Unit Electric Cooling
STEP 1 STEP 2 STEP 3 STEP 4 & 5
FIGURE 6 J To Shut OFF Unit Electric Cooling
MAIN
ON_
OFF
MAIN
STEP 1
STEP2
STEP3
ILl
Page 8
Fans and Fan Motors Periodically check the condition of fan wheels and housings
and fan-motor shaft bearings. Contact your dealer for the
required annual maintenance. Heat Exchanger
To ensure dependable and efficient heating operation, the
heat exchanger should be checked by a qualified maintenance person before each heating season, and
cleaned when necessary. This checkout should not be attempted by anyone not having the required expertise and
equipments to properly do the job. Contact your dealer for the required periodic maintenance.
Indoor and Outdoor Coils
Cleaning of the coils should only be done by qualified service personnel. Contact your dealer for the required
annual maintenance. Condensate Drain
The drain pan and condensate drain line should be checked and cleaned atthe same time the cooling coils are checked
by your dealer.
Compressor All compressors are factory shipped with a normal charge
of the correct type of refrigeration grade oil. A compressor should rarely require additional oil.
Condenser Fan
Unit Panels
After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the
correct unit airflow pattern. Combustion Area and Vent System
The combustion area and vent system should be inspected visually before each heating season. The normal
accumulation of dirt, soot, rust, and scale can result in loss of efficiency and improper performance if allowed to build
up. this inspection should be done by a trained service person.
FIRE, EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death and/or property damage.
If your unit makes an especially loud noise when the main burners are ignited, shut down the heating section and call your dealer.
BURN HAZARD
Failure to follow this caution may result in personal injury.
Components in heating section may be hot after unit has been started up. When observing flame, be careful not to
get close to or touch heating components.
PERSONAL INJURY AND UNIT DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Do not insert sticks, screwdrivers, or any other object into revolving fan blades.
The fan must be kept free of all obstructions to ensure
proper cooling. Contact your dealer for any required
service.
Electrical Controls and Wiring Electrical controls are difficult to check without proper
instrumentation. If there are any discrepancies in the
operating cycle, contact your local dealer and request service.
Refrigerant Circuit
The refrigerant circuit is difficult to check for leaks without the proper equipment. If inadequate cooling is suspected,
contact your local dealer for service.
EXPLOSION AND ENVIRONMENTAL HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow-control devices,
including solenoid valves.
Regular Dealer Maintenance
In addition to the type of routine maintenance you might be
willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection
(preferably each year, but at least every other year) should include the following:
1. Inspection of all flue product passages-including the
burners, heat exchanger, and flue collector box. Make sure the burner flames are blue in color and in proper adjustment. Refer to Figure 7 for burner flame.
FIGURE 7 I Monoport Burner
J
BURNER FLAME
.... ......../.....t.......
2. Inspection of all combustion-and ventilation-air passages and openings.
3. Close inspection of all gas pipes leading to and inside of your unit.
4. Inspection and, if required, cleaning of the outdoor and indoor coils.
Page 9
5.Inspectionand,ifrequired,cleaningoftheindoorcoil condensatedrain.
6.Inspectionandcleaningofblowerwheelhousingand
motor.
7.Inspectionofall supply-airandreturn-airductsfor
leaks, obstructions,and insulationintegrity.Any problemsfoundshouldberesolvedatthistime.
8.Inspectionoftheunitbaseto ensurethatnocracks, gaps, etc., exist which may causea hazardous
condition.
9.Inspectionoftheunitcasingforsignsofdeterioration.
10.Inspectionofallelectricalwiringandcomponentsto ensureproperconnection.
11.Inspectionfor leaks in the refrigerantcircuit.
Pressure-checktodetermineappropriaterefrigerant
charge.
12.Operationalcheckof theunitto determineworking conditions.Repairoradjustmentshouldbemadeatthis
time.
Yourservicingdealermayofferan economicalservice contractthatcoversseasonalinspections.Askforfurther
details. Completeserviceinstructionscanbefoundin the unit
Installation,Start-upandServiceInstructions.
WarrantyCertificate Yourheatingandairconditioningunithasalimitedwarranty.
Besureto readthewarrantycarefullyto determinethe
coverageforyourunit.
Beforeyoucallforservice...
...checkforseveraleasily-solvedproblems.
If insufficient heating or cooling is suspected:
( ) Check the air filter for dirt. ( ) Check for blocked return-air or supply-air grilles. Be
sure they are open and unobstructed. Ifthese checks do not reveal the cause, call your servicing dealer.
If your unit is not operating at all, check the following list for easy solutions:
( ) Check to be sure that your thermostat temperature selector is set below the indoor temperature during the cooling season or above the indoor temperature during
heating season. Be sure the SYSTEM switch or MODE control is in the COOL or HEAT position and not in the OFF
position.
( ) Ifyour unit still fails to operate, call your servicing dealer for troubleshooting and repairs. Specify the model and
serial numbers of your unit. (Record them in this manual in the space provided.) If the dealer knows exactly which unit
you have, he may be able to offer suggestions over the phone, or save valuable time through knowledgeable
preparation for the service call.
In Case of Trouble
If you perform the steps above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.
NOTE TO EQUIPMENT OWNER:
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # Serial #
ACCESSORIES (List type and model #)
NOTE TO INSTALLER:
This manual must be left with the equipment owner.
INSTALLATION INFORMATION
Date Installed DEALERSHIP CONTACT INFORMATION
Company Name Address
Phone Number
Technician Name