ICP PAX360000K00A1, PAX348000K00A1, PAX342000K00A1, PAX330000K00A1, PAX324000K00A1 Owner’s Manual

Package Air Conditioner
Owner's Guide to Operating and Maintaining
Your Package Air Conditioner
ELECTRICAL SHOCK HAZARD.
Failure to follow this warning could result in personal injury, death and/or property damage.
Disconnect power at fuse box or service panel before performing recommended maintenance.
Printed in U.S.A.
Code:PAX3 12/27/05 519 02 1101 00
EFFICIENT COOLING
Your new unit is among the most energy-efficient and
reliable air conditioning products available today. To
assure its dependability, spend just afew minutes with this
booklet now. Learn about the operation of your air
conditioner and the small amount of maintenance it takes to keep it operating at its peak efficiency.
With minimal care, your air conditioner will provide you and your family with satisfying home comfort [7both now and for years to come.
MlnlmomOlearoooeso°oAooesspaoe,so.ass, s.owo,
Blower Compartment Panel
80"
80-00-01
Control Box
IMPORTANT FACTS
To better protect your investment and to eliminate
unnecessary service calls, familiarize yourself with the
following facts:
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Improper installation, adjustment, alteration, service, maintenance or use could cause fire, electrical shock
or other conditions which may cause personal injury, death or property damage.
accumulate around or on top ofthe unit. Maintain a 12-in.
minimum clearance between the outdoor unit and tall
grass, vines, shrubs, et cetera.
Your multipurpose indoor thermostat is the control center for your air conditioning system. You should familiarize yourself with its proper operation. Attempting to control the system by other means - for instance, switching the
electrical supply power ON and OFF - may cause
damage to the unit.
Thermostat "jiggling" causes rapid-cycling, which is
potentially damaging to the compressor. Do not move the
temperature selector on the thermostat for any reason for at least 5 minutes after the compressor has shut off.
You may find that you can maintain greater personal comfort by running the fan continuously. Air pockets can form due to the structure of the building, placement of
registers, et cetera. These air pockets may be too cool or
warm for your liking. Continuous fan operation minimizes any temperature differences. Also, systems equipped
with electronic air cleaners and/or humidifiers offer the added benefits of having the air continuously cleaned year-round, and humidified during the winter season.
Your air conditioner will remove humidity from your home during the cooling season. After a few minutes of operation, you should be able to see water trickle from the condensate drain of the cooling coil. Check this occasionally to be sure the drain system is not clogged.
Ofcourse, don't expect to see much drainage if you live in
a very dry environment.
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified personnel should install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of cleaning coils and filters. All other operations
should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags, and labels attached to the unit, and other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for unbrazing operations.
Have fire extinguisher available for all brazing operations.
Refer to this manual. For assistance or additional information consult a qualified installer, service
agency, distributor, or branch. The qualified installer or agency must use only factory authorized kits or
accessories when modifying this product.
Your air conditioning system should never be operated without a clean air filter properly installed. Plan to inspect the filter monthly and replace if dirty. A clogged air filter
will increase operating costs and shorten the life of the
unit.
Supply-air and return-air registers should not be
blocked. Drapes, furniture, and toys are some of the items commonly found obstructing grilles. Restricted
airflow lessens the unit's efficiency and life span.
Outdoor units must have unrestricted airflow. Do not cover the unit, lean anything against it, or stand upon it.
Do not allow grass clippings, leaves, or other debris to
FIRE AND ELECTRICAL SHOCK HAZARD
Improper installation, adjustment, alteration, service, maintenance, or use can cause fire or an explosion
which could result in personal injury or unit damage.
Consult a qualified installer, service agency, or gas
supplier for information or assistance. The qualified
installer or agency must use only factory-authorized kits
or accessories when modifying this product.
FIRE, AND ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death and/or property damage.
Before performing service or maintenance operations
on unit, turn off gas supply to unit. Then turn off unit main
power switch and install lockout tag.