ICP N9MSE1402420A1, N9MSE1202420A1, N9MSE1002120A1, N9MSE1002114A1, N9MSE0802120A1 Owner’s Manual

...
Page 1
HOME OWNER’S INFORMATION
High Efficiency
Condensing Gas Furnace
Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.
USER: Please read all instructions in the manual and
retain all manuals for future reference.
! WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in personal injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a nearby
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
! WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Install a carbon monoxide alarm in your home, even if you do not own a gas appliance. Locate the carbon monoxide alarm in the living area of your home and away from gas appliances and doorways to attached garages. Follow the alarm manufacturer’s instruction included with the alarm.
Illustrations and photographs are only representative. Some product models may vary.
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury, death, or property damage.
Do not use this furnace if any part has been under water. A flooddamaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and to replace all gas controls, control system parts, or electrical parts that have been wet, or the entire furnace if deemed necessary.
WARNING
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org .
Specifications subject to change without notice.
! WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow this warning exactly could result in dangerous operation, serious injury, death or property damage.
Improper servicing could result in dangerous operation, serious injury, death or property damage.
S Before servicing, disconnect all electrical power to furnace. S When servicing controls, label all wires prior to
disconnecting. Reconnect wires correctly.
S Verify proper operation after servicing
440 02 4001 07 8/9/2017
Page 2
TABLE OF CONTENTS
FURNACE COMPONENTS 2...............................
IMPORTANT FACTS (DO’S AND DON’TS) 2..................
SAFETY CONSIDERATIONS 2..............................
BEFORE STARTING YOUR FURNACE 4.....................
STARTING YOUR FURNACE 4.............................
STEPS FOR STARTING YOUR FURNACE 4..................
SHUTTING DOWN YOUR FURNACE 6......................
MINIMUM AND MAXIMUM TEMPERATURE
SETTING FOR YOUR FURNACE 6..........................
PERFORMING ROUTINE MAINTENANCE 6..................
FILTERING OUT TROUBLE 6...............................
COMBUSTION AREA AND VENT SYSTEM 7.................
WINTERIZATION 8........................................
BEFORE YOU REQUEST A “SERVICE CALL” 9...............
MAINTENANCE CHECKLIST 10..............................
FURNACE COMPONENTS
(Furnace shown in upflow position; may be used in downflow or horizontal orientation or applications. Vent Elbow may be turned to a different position, depending on type of installation)
Figure 1 Furnace Components
HOT SURFACE IGNITER
MANUAL RESET ROLLOUT SWITCH
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
INDUCER MOTOR ASSEMBLY
BLOWER AND MOTOR
CAPACITOR/ POWER CHOKE
A170127
FLAME SENSOR
MANUAL RESET ROLLOUT SWITCH
GAS VALVE
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)
BLOWER DOOR SAFETY SWITCH
FURNACE CONTROL BOARD
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
GAS BURNER
IMPORTANT FACTS (DO’S AND DON’TS)
S DO: READ AND UNDERSTAND THIS MANUAL. S DO: Have your furnace and vent system inspected annually
by a qualified service technician.
S DO: Inspect your filter monthly and clean or replace when
needed.
S DO: Provide adequate airflow to the furnace for efficient
combustion and safe ventilation.
S DO: Keep your furnace free and clear of combustible
material.
S DO: Keep your furnace free and clear of insulating material.
Some materials may be combustible. Examine the furnace area when the furnace is installed or when insulation is added.
S DO NOT: Keep combustible materials, gasoline, and other
flammable liquids or vapors around your furnace.
S DO NOT: Cover your furnace in any manner.
S DO NOT: Store anything (including trash or debris) near your
furnace.
S DO NOT: In any way block or restrict airflow around your
furnace.
S DO NOT: In any way block or restrict airflow to your supply air
and return air grills.
S DO NOT: Use your furnace room as a broom closet or a place
to store any kind of chemical or cleaner.
S DO NOT: Contaminate the air used for combustion of your
furnace with any kind of chemical or fumes. This could also cause heat exchangers or components to deteriorate.
NOTE: These chemicals or fumes are present in many products around the home, such as: water softener salts, any type of household cleaning product, any type of laundry product, adhesives, paints, varnishes, paint strippers, waxes and plastics, etc.
During remodeling be sure the combustion air is fresh and uncontaminated. If these compounds are burned in your furnace, the heat exchangers may deteriorate.
NOTE: The qualified installer or agency must use only factoryauthorized replacement parts, kits, and accessories when modifying this product.
This furnace contains safety devices which must be manually reset. If the furnace is left unattended for an extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See “Before You Request a Service Call” section in this manual.
! WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in personal injury, death, or property damage.
Keep insulation and combustible materials clear of furnace and maintain clearances shown on unit clearance label.
Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace.
SAFETY CONSIDERATIONS
Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning or replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace, and other safety precautions that may apply. Recognize safety information. This is the safetyalert symbol
. When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety−alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
S Your new gas furnace may have been installed in one of two
ways, as a directvent (2pipe, Figure 2) application or as a
2
Specifications subject to change without notice.
440 02 4001 07
Page 3
nondirectvent (1pipe, Figure 3) application.
S In a directvent (2pipe) application, your furnace uses air
from outside the home for combustion and vents flue gas to the outdoors. This type of application will have two pipes running from the furnace to the outdoors (see Figure 2). In this application, the vent and airintake pipes must terminate outside the structure and must not be obstructed in any way. In some cases, the inlet air pipe may be located in an area that has access to outdoor air, such as an attic. In all cases, the outlet vent pipe must be routed to the outdoors. Do not bock or obstruct air openings on furnace or spaces around furnace.
S In a nondirect vent (1pipe) application, your furnace
uses air from adjacent to the furnace for combustion and vents flue gas to the outdoors. This type of application will have only one pipe running from the furnace to the outdoors. (see Figure 3) The other pipe will terminate in the same space as the furnace and is the source of combustion air for your furnace. Therefore, the furnace must not be enclosed in an airtight room or be sealed behind solid doors. It must have adequate airflow for efficient combustion and safe ventilation. Do not obstruct the combustionair pipe in any way. The vent pipe must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings or space around furnace.
Figure 2 Exterior Vent Pipes
L11F046
Figure 3 Interior Combustion Air Pipe
S Keep the area around your furnace clear and free of
combustible materials, gasoline, and other flammable liquids and vapors.
! WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, or property damage.
Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace.
Figure 4
S Do not cover the furnace, store trash or debris near it, or in
any way block the flow of fresh air to the unit.
In addition to the safety rules above, make sure that the following combustion−air requirements are met for nondirect
vent applications:
S Combustion air must be clean and uncontaminated with
chlorine or fluorine. These compounds are present in many products around the home, such as: water softener salts, laundry bleaches, detergents, adhesives, paints, varnishes, paint strippers, waxes, and plastics.
S Make sure the combustion air for your furnace does not
contain any of these compounds. During remodeling be sure the combustion air is fresh and uncontaminated. If these compounds are burned in your furnace, the heat exchangers may deteriorate.
S A furnace installed in an attic or other insulated space must
be kept free and clear of insulating material. Examine the furnace area when the furnace is installed or when insulation is added. Some insulation materials may be combustible.
!
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Should the gas supply fail to shut off or if overheating occurs, turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag.
NO Combustible materials near furnace
WARNING
440 02 4001 07
This furnace contains SAFETY DEVICES which must be MANUALLY RESET. If the furnace is left unattended for an extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See “Before You Request a Service Call” section in this manual.
L11F047
Specifications subject to change without notice.
3
Page 4
!
CAUTION
UNIT OPERATION HAZARD
Failure to follow this caution may result in intermittent unit operation.
For proper and safe operation the furnace needs air for combustion and ventilation. Do not block or obstruct air openings on the furnace, air opening to the area in which the furnace is installed, and the space around the furnace.
BEFORE STARTING YOUR FURNACE
Examine the furnace installation to determine that:
1. All flue gas carrying areas external to the furnace are clear and free of obstructions.
2. The vent connector is in place, slopes upward and is physically sound without holes or gaps.
3. The returnair duct connection(s) is physically sound, is sealed to the furnace casing, and terminates outside the space containing the furnace.
4. The physical support of the furnace is sound without sagging cracks, gaps, etc. around the base.
5. There are no obvious signs of deterioration of the furnace.
6. The burner flames are in good adjustment, see Figure 5 (by comparison with pictorial sketches or drawings of the main burner flame).
Figure 5 Burner Flame Adjustment
Burner Flame
Burner
Figure 7
S If a suspected malfunction occurs with your gas control
system, such as the burners do not light when they should, refer to the shut down procedures on inside of main furnace door, or in the “Shutting Down Your Furnace” section and call your dealer as soon as possible.
S CHECK AIR FILTER: Before attempting to start your
furnace, be sure the furnace filter is clean and in place. See “Performing Routine Maintenance” section in this manual. Do not run the furnace without a filter in place. Then proceed as follows:
Operating Instructions Inside Door
FOR YOUR SAFETY READ BEFORE OPERATING
OPERATING
INSTRUCTIONS
L11F048
STEPS FOR STARTING YOUR FURNACE
1. Set your room thermostat mode to off and adjust the set point to the lowest temperature setting.
Figure 8 Lowest Temperature Setting
40
Manifold
A11461
STARTING YOUR FURNACE
Your furnace uses an automatic, hot surface ignition system to light the burners each time the thermostat signals the furnace to start.
Follow these important safeguards:
S Never attempt to manually light the burners with a
match or other source of flame.
Figure 6 Do Not Light Burner with Match
S Read and follow the operating instructions on the
inside of main furnace door (see Figure 7) , especially the item that reads as follows: “Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on this furnace label. If you don’t smell gas, go to the next step.”
A92319
2. Close the external manual gas valve.
Figure 9 Close Valve
C
L
O
S
E
L11F049
A06188
4
Specifications subject to change without notice.
440 02 4001 07
Page 5
3. Turn OFF electrical supply to the furnace.
Figure 10 Turn off Electrical Supply
A92185
4. Remove the outer door by turning knobs, then pull door forward.
Figure 11 Remove Furnace Door (upflow shown)
6. Turn the control switch to ON.
Figure 13 Control Switch to ON
SINGLE-STAGE GAS CONTROL
GAS CONTROL SWITCH
SHOWN IN “ON” POSITION
MODULATING GAS CONTROL
ON
OFF
GAS CONTROL SWITCH
SHOWN IN “ON” POSITION
7. Replace the outer door by placing flange inside casing, push door firmly against casing and turn knobs to tighten.
TWO-STAGE GAS CONTROL
CONSULT
MANUAL BEFORE
ADJUSTING
GAS
PRESSURE
NAT. GAS
A11291
Figure 14 Furnace Door Replaced
A11302
5. Turn the control switch on the gas control to the OFF
position and wait 5 minutes. See Figure 12. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on furnace label and follow the safety information on the cover of this manual. If you don’t smell gas, go to next step.
Figure 12 Control Switch to OFF
CONSULT
MANUAL BEFORE
ADJUSTING
GAS
PRESSURE
NAT. GAS
TWO-STAGE GAS CONTROL
A11292
SINGLE-STAGE GAS CONTROL
ON
OFF
GAS CONTROL SWITCH
SHOWN IN “OFF” POSITION
MODULATING GAS CONTROL
GAS CONTROL SWITCH
SHOWN IN “OFF” POSITION
A11301
8. Turn ON the electrical supply to the furnace.
Figure 15 Turn On Electrical Supply
A92359
440 02 4001 07
Specifications subject to change without notice.
5
Page 6
9. Open the external manual gas valve.
Figure 16 Open Valve
O
P
E
N
A06189
10. Set the room thermostat mode to “heat” and adjust the setpoint to a temperature slightly above the room temperature. This will automatically signal the furnace to start. The combustion air draft inducer motor will start and the hot surface igniter will energize. When hot, the igniter will have an orange glow.
11. After about seventeen (17) seconds, the gas valve permits gas to flow to the main burners where it is ignited. Hot flames begin to warm the furnace’s heat exchanger. After a time delay of approximately twentyfive to sixty (2560) seconds the furnace blower is switched on.
NOTE: If the main burners fail to ignite, the furnace control system will go through three more ignition cycles. Then if burners fail to ignite, the system will lockout. If lockout occurs or the blower does not come on, shut down your furnace and call your dealer for service.
12. Set your thermostat to the temperature that satisfies your comfort requirements.
SUGGESTION: Setting the thermostat back a few degrees—and compensating for the difference with warmer clothing—can make a big difference in your fuel consumption on extremely cold days. The few degrees at the top of your thermostat “comfort level” are the most costly degrees to obtain.
When the room temperature drops below the temperature selected on the thermostat, the furnace will switch on automatically. When the room temperature reaches the setting selected on the thermostat, the furnace will be automatically switched off.
Continuous Fan Operation Some thermostats have a “FAN” switch with two (2) selections: AUTO and ON. When thermostat is set on AUTO, the furnace blower cycles on and off, controlled by the thermostat. In ON position, the furnace blower runs continuously except for a fortytwo to sixty−two (4262) second delay at the “call for heat.” Continuous fan keeps the temperature level in your home more evenly balanced. It also continuously filters the indoor air.
SHUTTING DOWN YOUR FURNACE
Should you ever suspect a malfunction in your furnace, you will need to turn the furnace off. The following procedures must be followed:
1. Set your room thermostat mode to the lowest
temperature setting and set to OFF. (See Figure 8)
2. Close the external manual gas valve (See Figure 9).
3. Turn off electrical supply to the furnace. (See Figure 10)
4. Remove outer furnace door. (See Figure 11)
5. Turn the switch on the gas control to the OFF position.
(See Figure 12)
6. Replace the outer furnace door. (See Figure 14)
7. If the furnace is being shut down because of a malfunction, call your dealer as soon as possible.
6
Specifications subject to change without notice.
MINIMUM AND MAXIMUM TEMPERATURE
SETTING FOR YOUR FURNACE
This furnace is designed for minimum continuous return−air temperature of 60°F (15°C) db or intermittent operation down to 55°F (15°C) db such as when used with a night setback thermostat. Returnair temperature must not exceed 80°F (27°C) db. Failure to follow these returnair temperature limits may affect reliability of heat exchangers, motors, and controls.
PERFORMING ROUTINE MAINTENANCE
With proper maintenance and care, your furnace will operate economically and dependably. Instructions for basic maintenance are found on this and the following pages. However, before beginning maintenance, follow these safety precautions:
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace before removing the access doors to service or perform maintenance.
CUT HAZARD
Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp edges, be extremely careful when handling parts or reaching into the furnace. Wear safety glasses, gloves, and appropriate protective clothing.
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety glasses, gloves, and appropriate protective clothing.
WARNING
!
CAUTION
!
CAUTION
FILTERING OUT TROUBLE
!
UNIT PERFORMANCE HAZARD
Failure to follow this caution may result in product damage.
Never operate your furnace without a filter in place. Doing so may damage the furnace blower motor. An accumulation of dust and lint on internal parts of your furnace can cause a loss of efficiency.
NOTE: The manufacturer has specified filters which will enable your furnace to provide lasting comfort and efficiency throughout its life. Contact your dealer to help you choose filters for your furnace that both collect dirt before it enters your furnace, as well as provide a low resistance to circulating air. Avoid filters that report high cleaning efficiencies, but do not allow air to pass easily through them.
A dirty filter will cause excessive stress on the furnace, heat exchanger, and blower motor, and can cause the furnace to
CAUTION
440 02 4001 07
Page 7
overheat and automatically shut down. The furnace filter should be checked every four weeks and cleaned or replaced if necessary.
If installed with disposable media filter, check or replace filter before each heating and cooling season. Replace disposable media filter at least twice a year.
If your furnace filter needs replacing, be sure to use the same size and type of filter that was originally specified.
The air filter for the furnace may be located in a filter cabinet/rack attached to the side or bottom of the furnace. If air filter has been installed in another location, contact your dealer for instructions. To inspect, clean and/or replace the air filter(s), follow these steps:
1. Turn off the electrical supply to the furnace (see
Figure 10)
2. Remove filter cabinet door/cover.
3. Slide air filter out of filter cabinet/rack. Keep dirty side up (if dirty) to avoid spilling dirt.
4. Inspect the filter. If torn, replace it.
NOTE: If the filter is:
a. a disposable media filter — Do not clean. If dirty,
replace only with media filter having the same part number and size. Install with airflow direction arrow pointing towards blower.
b. an Electronic Air Cleaner (EAC) — Refer to EAC
Owner’s Manual for maintenance information.
c. a washable filter, wash filter (if dirty) in sink, bathtub,
or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow filter to dry.
5. Reinstall clean air filter.
6. Replace filter cabinet door.
7. Turn on electrical supply to furnace (See Figure 15).
NOTE: If side return ducts are used, two filters may be required in some models. The procedure listed above may be used to remove side filters.
Washable filters may be field modified by cutting filter material and support rods (3) in filters. Alternate sizes and additional filters may be ordered from your dealer.
Filter Size Information inch (mm)
FURNACE CASING
WIDTH
14-3/16 (360) 16 x 25 x 3/4 (406 x 635 x 19) 14 x 25 x 3/4 (356 x 635 x 19) Washable*
17-1/2 (445) 16 x 25 x 3/4 (406 x 635 x 19) 16 x 25 x 3/4 (406 x 635 x 19) Washable*
21 (533) 16 x 25 x 3/4 (406 x 635 x 19) 20 x 25 x 3/4 (508 x 635 x 19) Washable*
24-1/2 (622) 16 x 25 x 3/4 (406 x 635 x 19) 24 x 25 x 3/4 (610 x 635 x 19) Washable*
* Recommended to maintain air filter face velocity. See Specification for part number.
**Some furnaces may have 2 filters
SIDE RETURN BOTTOM RETURN
FILTER SIZE
COMBUSTION AREA AND VENT SYSTEM
! WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
For proper and safe operation the furnace needs air for combustion and ventilation. Do not block or obstruct air openings on the furnace, air opening to the area in which the furnace is installed, the inlet and vent openings on the exterior of home, and the space around the furnace.
Inspect the combustion area and vent system before each heating season. An accumulation of dirt, soot, or rust can mean a loss of efficiency and improper performance. Buildups on the main burners can cause faulty firing. This “delayed ignition” is characterized by an alarmingly loud sound.
NOTE: If your furnace makes a loud noise when the main burners are ignited, shut down the furnace and call your servicing dealer. Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace:
1. Turn off gas and electrical supply to the furnace and remove the access door. (See Figure 9 and Figure 11)
2. Carefully inspect the gas burner for dirt, rust, or scale.
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
If dirt, rust, soot, or scale accumulations are found, call your dealer. Do not operate your furnace.
3. Inspect the vent pipe for a sag, holes, or a disconnection. A horizontal vent pipe must slope upward away from furnace. If open joints or seams, or signs of water leakages are found, call your dealer for service.
4. If your furnace is free of the above conditions, turn on gas and electrical supplies to the furnace. (See Figure 15 and Figure 16)
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
If holes are found or if the vent pipe is obstructed or is not connected, toxic fumes can escape into your home. DO NOT OPERATE YOUR FURNACE. Call your dealer for service.
WARNING
!
WARNING
FILTER TYPE
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace before removing the access doors to service or perform maintenance.
440 02 4001 07
WARNING
Specifications subject to change without notice.
5. Restore electrical power to the furnace.
6. Start the furnace and observe its operation. If possible, watch the burner flames. Are they burning bright blue? If not or if you suspect some other malfunction, call your servicing dealer.
7. Replace the access door. (See Figure 14)
7
Page 8
WINTERIZATION
!
CAUTION
UNIT AND PROPERTY OPERATION HAZARD
Failure to follow this caution may result in unit component or property damage.
If the furnace is installed in an unconditioned space where the ambient temperatures may be 32° F (0° C) or lower, freeze protection measures must be taken to prevent minor property or product damage.
!
CAUTION
UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in damage to the furnace and other property damage.
Do not use ethylene glycol (Automotive antifreeze coolant or equivalent). Failure of plastic components may occur.
Since the furnace uses a condensing heat exchanger, some water will accumulate in the unit as a result of the heat transfer process. Therefore, once it has been operated, it cannot be turned off and left off for an extended period of time when temperatures will reach 32° F (0° C) or lower unless winterized. Follow these procedures to winterize your furnace:
1. Obtain propylene glycol (RV/swimming pool antifreeze or equivalent).
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace before removing the access doors to service or perform maintenance.
2. Turn off gas and electrical supplies to your furnace. See Figure 9 and Figure 10.
3. Remove furnace control compartment door. See Figure 11.
4. Remove one of the unused rubber plugs in the port on the collector box opposite the condensate trap. See Figure 17.
5. Connect a field supplied 3/8-in. (9.5-mm) ID tube to the open port on the collector box. See Figure 17.
WARNING
Figure 17 Antifreeze into Funnel/Tube
Representative drawing only, some models may vary in appearance.
L11F065
6. Insert a field supplied funnel into the tube.
7. Pour one (1) quart of antifreeze solution into the funnel/tube. Antifreeze should run through the inducer housing, overfill condensate trap and flow to an open drain.
8. If a condensate pump is used, check with pump manufacturer to verify pump is safe for use with antifreeze used. Allow pump to start and pump antifreeze to open drain.
9. Remove funnel and tube from collector box.
10. Replace plug in collector box.
11. Remove other plug and repeat steps 4 through 10.
12. Replace main door. See Figure 14.
13. When furnace is re-started, flush condensate pump with clear water to check for proper operation before re-starting furnace.
14. Antifreeze need not be removed before re-starting furnace.
8
Specifications subject to change without notice.
440 02 4001 07
Page 9
BEFORE YOU REQUEST A
“SERVICE CALL”
If your furnace is not operating or not performing properly, you may save the expense of a service call by checking a few things yourself before calling for service:
This furnace has a light emitting diode (LED) status code display to aid the installer, service technician, or homeowner while installing or servicing the unit. The LED code can be seen through the view port in the blower access panel.
NOTE: Record the LED status code BEFORE removing the blower access door or turning off 115V power to the furnace. See the information booklet inside the main furnace door for a service code legend (See Figure 7)
S Check for sufficient airflow. Check the air filter for dirt. Check
for blocked returnair or supplyair grilles. Be sure they are open and unobstructed. If this isn’t the cause of the problem, call your servicing dealer. If your furnace isn’t operating at all, check the following list for easily solved problems:
S Is your thermostat set above room temperature? Is the HEAT
mode selected?
S Is the electrical power supply switch on? Is the blower access
door firmly in place? Are any fuses blown? (There is a fuse on the furnace control.) Has a circuit breaker tripped?
S Is the manual shut−off valve in the gas supply pipe leading to
the furnace open? Does the lever point in the same direction that the pipe runs (open)? Or is it at a right angle to the pipe (closed)? NOTE: Before proceeding with the next checks, turn off the electrical power supply to the furnace. Remove access door.
S Is the switch on the gas valve turned to the ON position? If
this or the preceding check shows an interruption in the gas supply, make sure the gas has not been shut off for safety reasons. If nothing else seems to be wrong, follow the startup procedures found on page 4 of this booklet.
S Check the two manual reset rollout switches located on the
burner enclosure. (See Figure 1 ) If the furnace has experienced a hightemperature condition due to inadequate combustion air, these switches will shut off the furnace. Reset the switches by pushing the button on the switch. If the switch trips a second time, turn off the furnace and call for service.
If your furnace still fails to operate, call your servicing dealer. Provide your dealer the model and serial numbers for your furnace. (You should have them recorded on the last page of this booklet.) By knowing exactly which furnace you have, the dealer may be able to offer suggestions over the phone or save valuable time through knowledgeable preparation for the service call.
440 02 4001 07
Specifications subject to change without notice.
9
Page 10
NOTE TO EQUIPMENT OWNER:
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information will be helpful should your system require maintenance or service.
FURNACE
Model # _____________________________________
Serial # ______________________________________
AIR CONDITIONER OR HEAT PUMP
Model # _____________________________________
Serial # _____________________________________
INDOOR COIL (Furnace Coil or Fan Coil)
Model # _____________________________________
Serial # _____________________________________
INSTALLATION INFORMATION:
Date Installed ________________________________
DEALERSHIP CONTACT INFORMATION:
Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________
_____________________________________________
NOTE TO INSTALLER:
This manual must be left with the equipment owner.
Monthly maintenance items may be performed by the homeowner. All other service and maintenance items MUST be performed by qualified service technicians
MAINTENANCE CHECKLIST
In addition to the type of routine maintenance you might be willing to perform; your furnace should be inspected regularly by a properly trained service technician.
You should work with your dealer or service technician to assure your inspection includes the following at a minimum.
DESCRIPTION
Monthly Semi-Annually Annually
Furnace specific, external items:
Clean or replace air filters. X Inspect cabinet for signs of damage. X Inspect electrical disconnect for proper function. Repair or replace as necessary. X Inspect external wiring for damage. X Inspect gas supply line and manual shutoff for leaks. X
Furnace specific, internal items:
Inspect gas valve and check for proper manifold gas pressure Adjust as needed. X Inspect ignition system and safety controls. Clean and adjust as needed. X Inspect control box, associated controls, wiring and connections. X Check combustion blower housing for lint and debris and clean as necessary. X Inspect burner assembly  clean as needed. X Inspect RPJ® heat exchanger  clean as needed. X
Inspect and clean blower assembly (includes blower housing, blower wheel and motor).
Inspect flue system—check for proper attachment to the furnace, any dislocated sections, and for signs of corrosion. Replace if necessary.
System:
Inspect airflow system (ductwork)—check for leaks and repair as needed. X
This list may not include all maintenance items, and inspection interval times may vary depending on operational conditions of the furnace.
Ask your servicing dealer for further details about an economical service contract that covers seasonal inspections.
Inspect evaporator coil, drain pan and condensate drain lines as applicable. Clean as needed.
INSPECTION INTERVAL
X
X
X
10
Copyright 2017 International Comfort Products
Lewisburg, Tennessee 37091 USA
Specifications subject to change without notice.
440 02 4001 07