ICP HMICLB17A, HMICSB12A Installation Guide

READ COMPLETE SAFETY |NSTRUCT|ONS AND |NSTALLATION TEMPLATE BEFORE STARTING
taller:
This product must be installed by a qualified heating and air conditioning contractor. Failure to do so, could result in serious injury from electrical shock. This product must be installed in compliance with atl local, state and federal codes.
SBP SMALL BYPASS HUMiDiFiER
The Small ByPass Humidifier can be installed on either the supply or return plenum of a forced air handling system Easy reversible installation right hand or left hand.
If the furnace has central cooling, the humidifier bypass duct must have a damper. The damper should be closed during the cooling season.
120VAC
"HUM" AND "N" TERMINALS
ON FURNACE
©2003 International Comfort Products (USA)
Lewisburg, TN 37091
Diegrom A:
FOR OPERATION DURING "HEAT CALL" ONLY
24 VAC SOLENOID VALVE LEADS
t20 VAC_'l _VAC
TRANSFORMER
TEMPLATE MUST BE LEVEL
HUMIDIFIER
Humidifier Control
DP10005943
616 01 1005 00
i
READ REVERSE SiDE FIRST J
TOP
i READ REVERSE SIDE FIRST i
READ COMPLETE SAFETY
1 Placeuniton flatsurfaceandpull
front cover up on right side.It snaps
loose.Removeevaporativeassembly.
6 Reinstall the evaporative assembly complete with the
evaporativemediaby fitting the drain tubeinto the round receptacleat the bottomofthe unit.Pushtheassembly in at thetop againstthebeveledtabs. Replacethe front cover and attach nameplate with appropriate brand name.
2 Theunitisassembledfor leftside discharge. If right discharge is
necessary,removethe right and left screws from the unit interior side
walls and exchange the two sides. Reassemblewithscrews.
7 DISCONNECT ELECTRICAL
POWER TO FURNACE BEFORE PROCEEDING. The Humidifier
Controlis designed for low voltage service to control humidification
equipment.An increase in relative humidity expands the nylon ribbon
that opens the controlswitchto stop
operation on the humidifier. A decrease in relative humidity reversestheprocess and closes the
controlswitch. Install the Humidifier Control.
iNSTRUCTiONS AND iNSTALLATiON TEMPLATE BEFORE STARTING
TEMPLATE MUST BE LEVEL
3 Usethistemplateformarkingthe
unitopeningtobecutinplenum.Draw alevellineatleastthreeinchesabove
furnace jacket for clearance of the
drain line and solenoid valve.Tape
templatein positionandtracearound
entire outside edges. Remove
template and accurately cut the
plenum opening accordingly,being carefulto avoid injury from sharp edges,
LOCATION
1. LocateHumidifierControlon insidewall of living area approximately5' above
floor,orin thefurnacereturnair plenum or duct. For return air plenum
installation use Humidifier Control Adapter Plate, Fast part # 4463
(Not Included/
2. Donot locatecontrolinthedirectpathof
furnacedischargeairor draftsfromopen doorsandwindows.
Do not install where operation might be
affected by lamps, sunlight, fireplace
registers, radiators, concealed air ducts
and pipes, or room occupants.
4. The basic rules for location of thermostats also apply to Humidifier
Control
4 Place the unit into the plenum opening so that the locking tabs on
the bottom are closed down onto the lower sheet metal edge. While holding
the unit in place, install two screws at the top of the unit interior. '
GENERALiNSTRUCTiONS
1. DO NOT ATTEMPTTO REPAIROR RECALIBRATE CONTROL. Controls requiringserviceshould bereturnedto
yourdistributor.
2. Control must beinstalled using 24 volts!
3. Make sure no bare wires are exposed or insulation damaged. Insulation on wire should extendto head of binding screws.
4.. Make sure all splices are mechanically and electrically secure.
5. To remove dirt or other foreign matter from nylon ribbon and control interior, dust lightly with a fine, soft brush.
5 Installa 6" collar in a convenient locationonthe oppositeplenum.Slip
on a 90° elbow and measure the length of 6" round duct requiredto
maketheconnection.The6"ductwill fit intotheroundcollaron thesideof
theunit. If the furnacehascentralair conditioning, add a duct damper.
Assemble components with sheet metalscrews.Supportbypassducts
in excessof4' topreventsagging.
Tapinto a watersupplytinewith
thesaddlevalvefurnished.Thehumid-
ifierwilI functionwith cold,hot, soft-
enedor unsoftenedwater.Theuseof servicehot water (140°FMAX.)and
constant blower operationwill pro- videmaximumevaporativecapacities.
NOTE:Thesaddlevalveisdesigned
to befullyopenedorclosed.Donot
useitto regulatewaterflow.
/
/
9 Connect tubing fromthe saddle
valve to the inlet side of the solenoid valve using 1/4" O.D. copper tubing
(not furnished). DOUBLE WRENCH
TO PREVENTLEAKING!
TO iNSTALL ON COPPER OR PLASTICPiPE
a) Place rubbergasket in center of
hole in top saddleclamp. Place top and bottom saddle clamp around water pipe. Using bolts, tightensaddle clamps, evenly- clampsshouldbe parallel- DO NOTover-tighten.
b) Screwvalvebodyinto openingin
topsaddleclampandtighten.
c) Tighten gland nut onto valve
body.
d) Install1/4"water supplylinefrom
humidifier using compression fittings.
e) Youare now readyto pierce the
pipe.Turnhandle untilspindleis firmlyseatedintovalvebody.The water pipe is now fully pierced. Turningspindleinshutsvalveoff. Openvalvecompletelyfornormal operation.
TOiNSTALLONSTEELOR BRASS
PiPE
a) Shut off water supply.Open any
faucetto relievewaterpressure.
b) Drill3/16"diameterholeinto pipe
wheresaddlevalvewillbeplaced.
c) Place rubbergasketin centerof
holeintop saddleclamp.
d) Placetop saddleclampassembly
over hole so that lance fits into hole.
e) Place top and bottom saddle
clamparoundwaterpipe.
f) Screwvalvebodyinto openingin
topsaddle clampandtighten.
g) Tighten gland nut onto valve
body.
h) Install1/4"water supplylinefrom
humidifier using compression
fittings. NOTE: For pipe over 1" O.D., use 1/4"-20,1-3/4"longbolts.
I_¸
/
/
1 0 Connect1/2"I.D.plastic hose (not furnished) from unit to floor
drain. Be sure drain hose has continuousslope. Use caution with
hose clamp, be sure not to over tighten and crack drain spud. Note: Do not sweat or directly attach metal drain line to fitting. Do not use solvent type adhesive when connecting plastic drain hose, since damage to fitting could
result.
1 1 Opensaddlevalveandturn on
furnace.Turn up HumidifierControl to operateunit.Allow unitto rununtil
water is observed coming out of drain line. Check to see if unit is
water tight and all electrical componentsfunctionproperly.Reset
HumidifierControl to recommended level.