ICP GRD8522RZ, GRD8622RZ Installation And User Manual

Preliminary
ICP RAID Controllers GDT8522RZ and GDT8622RZ
Dual Fibre Channel RAID Controllers Hardware Installation and User’s Guide, Version 1.0
April 2003
IMPORTANT NOTICE - READ BEFORE MAKING USE OF THE INFORMATION CONTAINED HEREIN
This information is provided “as is.” Information in this document is provided solely to enable use of ICP products. Except as provided in ICP vortex’s Terms and Conditions of sale ICP vortex and/or its suppliers assume no liability whatsoever, and ICP vortex and/or its suppliers disclaim any express or implied warranty, relating to this information including liability or warranties relating to fitness for a particular purpose, merchantability, satisfactory quality or infringement of any patent, copyright or other intellectual property right. ICP vortex and/or its suppliers assume no responsibility for any omissions or any errors which may appear in this document nor does it make a commitment to update the information contained herein.
ICP vortex retains the right to make changes to this document and its products at any time, without notice.
No License, express or implied, by Estoppel or otherwise, to any intellectual property rights is granted by this document. ICP products are not intended for use in medical, life saving, or life sustaining applications.
Any recommended operating or test methods are correct to ICP’s reasonable knowledge at the time of writing. ICP vortex and/or its suppliers accept no liability for the implementation of these methods within the user’s environment. The user is responsible for and must satisfy itself that any use made of this information or ICP products is suitable to its needs.
Any named third party suppliers are provided for information only. The hardware vendor remains solely responsible for the design, sale and functionality of its product, including any liability arising from product infringement or product warranty. ICP vortex accepts no liability for the quality of third party suppliers, and cannot guarantee that third party products are suitable or are compatible with ICP products or that third party suppliers will not change parts so that they are no longer compatible or no longer suitable.
IN NO EVENT WILL ICP VORTEX AND/OR ITS SUPPLIERS BE LIABLE TO THE RECIPIENT OR USER OF THIS INFORMATION FOR ANY LOSS OF PROFITS, LOSS OF USE, BUSINESS INTERRUPTIONS, INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS, LOSS OR CORRUPTION OF DATA, INCIDENTAL, INDIRECT, SPECULATIVE, CONSEQUENTIAL, OR SPECIAL DAMAGES, HOWSOEVER ARISING AND IRRESPECTIVE OF WHETHER ICP VORTEX HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
THE LIMITATIONS AND DISCLAIMERS SET FORTH HEREIN WERE AN ESSENTIAL ELEMENT IN ICP VORTEX AGREEING TO SUPPLY THIS INFORMATION FREE OF CHARGE. THEY SHALL APPLY NOTWITHSTANDING SECTION 1.1 OF THE TERMS AND CONDITIONS OF SALE OF ICP VORTEX
Hardware Installation and User’s Guide 3
Contents
1 Getting Started
1.1 Using the User Documentation Set ............................................................................................... 5
1.1.1 Document Formats ...................................................................................................... 6
1.2 About This Guide...........................................................................................................................6
1.3 Warnings and Cautions .................................................................................................................7
1.4 Customer Support Contact Information .........................................................................................7
1.5 Regulatory and Certification Information ....................................................................................... 7
1.5.1 Product Regulatory Compliance .................................................................................. 7
1.5.2 Product Safety Compliance ......................................................................................... 8
1.5.3 Product EMC Compliance ...........................................................................................8
1.5.4 Product Regulatory Compliance Markings ..................................................................8
1.5.5 Electromagnetic Compatibility Notices ........................................................................ 8
2 Hardware Installation
2.1 Installation Introduction ............................................................................................................... 11
2.1.1 Computer System Hardware Requirements .............................................................. 11
2.1.2 ICP RAID Controller Component Layout ...................................................................12
2.2 ICP RAID Controller Installation .................................................................................................. 13
2.2.1 Installing the ICP RAID Controller Card.....................................................................13
2.2.2 Jumper Settings .........................................................................................................15
2.2.3 SCSI Termination ......................................................................................................17
2.3 Fibre Channel Configuration ....................................................................................................... 17
2.3.1 Configuring Single and Dual Loop Connections ........................................................18
2.3.2 Fibre Channel Loopback............................................................................................ 18
2.4 ICP RAID Controller Diagnostic Features ................................................................................... 18
2.4.1 LED Indicators ...........................................................................................................19
2.4.2 Audible Alarm ............................................................................................................20
2.4.3 Beep Sequences During System Boot ......................................................................21
3 Hardware Specifications and Features
3.1 ICP RAID Controller Hardware Features..................................................................................... 23
3.1.1 ICP RAID Controller Key Features ............................................................................23
3.2 Operating System Support .......................................................................................................... 25
3.3 Supported Fibre Channel Technology.........................................................................................25
3.3.1 ICP RAID Controllers and Fibre Channel Arbitrated Loop (FC-AL) ........................... 25
3.3.2 FC-AL Single and Dual Loop Configurations ............................................................. 26
3.4 Supported SCSI Technology.......................................................................................................27
3.4.1 Supported Hard Drive Technology ............................................................................27
3.4.2 Support for Non-Hard-Disk-Drive SCSI Devices (Non-Direct-Access Devices) ........28
3.5 Array Roaming Compatibility....................................................................................................... 28
3.6 Fibre Channel Hot-Plug Disk Drive Support ................................................................................ 29
3.7 Configurable Parameters ............................................................................................................ 29
3.7.1 Configurable Fibre Channel Parameters ................................................................... 30
3.7.2 Configurable SCSI Parameters .................................................................................30
3.8 RAID Controller Drive Maximum Quantities (Host, Array, Logical, and Physical) .......................31
3.8.1 RAID Controller Drive Quantities with Fibre Channel ................................................ 31
4 Hardware Installation and User’s Guide
3.8.2 RAID Controller Drive Quantities with SCSI .............................................................. 32
A Flash Memory Programming
A.1 About Firmware Files.................................................................................................................. 33
A.2 Updating Firmware Using the FRUU .......................................................................................... 33
A.2.1 Creating Firmware Diskettes from the CD-ROM Autorun Menu................................ 34
A.2.2 Creating Firmware Diskettes from the Bootable RAID Software Suite CD-ROM ...... 35
A.2.3 Running the FRUU .................................................................................................... 35
A.3 Firmware Update Procedure via XROM ICPCON ...................................................................... 36
A.4 Firmware Recovery .................................................................................................................... 37
B Fibre Channel Cabling and Connections
B.1 Optical Cabling ........................................................................................................................... 38
B.1.1 Multimode Cable........................................................................................................ 38
B.1.2 Single Mode Cable .................................................................................................... 38
B.2 Copper Cabling........................................................................................................................... 38
B.3 Fibre Channel Adapters and Connectors ................................................................................... 39
B.3.1 Adapters .................................................................................................................... 39
B.3.2 Optical Cabling Connectors....................................................................................... 40
B.3.3 Electrical Cabling Connectors.................................................................................... 41
Index
Figures
2-1 ICP RAID Controller Component Layout (Front) ........................................................................ 12
2-2 ICP RAID Controller Component Layout (Bracket) .................................................................... 13
2-3 Installing the ICP RAID Controller into a Computer System....................................................... 14
2-4 Installing the ICP RAID Controller into a Computer System....................................................... 15
2-5 Jumper Settings and Locations .................................................................................................. 16
2-6 ICP RAID Controller LED Indicators (Bracket) ........................................................................... 19
2-7 ICP RAID Controller LED Indicators (Front) ............................................................................... 19
Tables
2-1 Jumper Descriptions................................................................................................................... 17
2-2 ICP RAID Controller LED Descriptions....................................................................................... 19
2-3 Beep Sequences ........................................................................................................................ 21
3-1 Hardware Architecture ................................................................................................................ 24
3-2 Environmental Specifications ..................................................................................................... 24
3-3 FC-AL Specifications .................................................................................................................. 26
3-4 Supported SCSI Device Standards ............................................................................................ 27
3-5 Configurable Fibre Channel Parameters .................................................................................... 30
3-6 Configurable Disk Drive SCSI Parameters................................................................................. 30
3-7 Configurable I/O Controller SCSI Parameters ............................................................................ 31
3-8 RAID Controller Drive Maximum Quantities with Fibre Channel ................................................ 31
3-9 RAID Controller Drive Maximum Quantities with SCSI .............................................................. 32
Hardware Installation and User’s Guide 5
Getting Started
Getting Started
1
Intended Audience
This documentation is intended for users who are experienced in configuring computer systems with new add-in cards or have had previous experience with ICP RAID Controllers.
Read and adhere to all warnings, cautions, and notices in this guide and the other documents in the user documentation set supplied with this product.
1.1 Using the User Documentation Set
User documentation for this product is provided in four separate documents. Not all of them must be part of the printed documentation. You will find the following documents on the RAID software suite CD-ROM:
Quick Installation Guide
The Quick Installation Guide provides a high level view of installing and configuring a RAID controller. Refer to the accompanying Software Guide for more detailed information.
Hardware Installation and User’s Guide
The Hardware Installation and User’s Guide, or Hardware Guide, covers instructions for installing an ICP RAID Controller and provides a guide to its features and specifications. For a particular ICP RAID Controller, its hardware guide documents compatible RAID adapters, supported operating systems, standard features and optional features.
Software Installation and User’s Guide
The Software Installation and User’s Guide, or Software Guide, contains:
Quick installation of the ICP RAID Controller software on a newly created bootable
host drive with commonly used operating systems.
Detailed instructions covering more complex software installation scenarios for all
supported operating systems.
Instructions for using the RAID Software Suite, the drivers, tools and utilities of the
ICP RAID Controller.
The first part of the software guide provides an overview of RAID technology and its features. Next, the guide documents various installation procedures for an ICP RAID Controller and the RAID Software Suite, depending on the chosen OS configuration. The software guide then includes descriptions of the utilities, ICP RAID Console (ICPCON) and ICP RAID Navigator (ICP RAID Navigator), to facilitate the configuration of the RAID subsystem. Finally, the guide provides details of all product features supported by
6 Hardware Installation and User’s Guide
Getting Started
the software and firmware For further information refer to the Optional Features section of the appropriate hardware guide since not all features are applicable to all ICP RAID Controllers.
Clustering Guide
The ICP RAID Clustering Guide, or Clustering Guide, describes how to set up clustering configurations using ICP RAID Controllers and ICP RAID Controller software.
Information on Operating Systems, Cluster functionality, and other system details may be found in their corresponding system manuals.
1.1.1 Document Formats
All documents, with the exception of the quick start poster, are provided on the CD-ROM in both PDF and HTML format:
HTML—To view online HTML documents, Click Documentation from the autorun
menu or open <cdromdrive>:\docs\index.htm.
PDF—Portable Document Format (PDF) documents can be opened, viewed, and
printed with Adobe* Acrobat Reader* (not provided on the CD-ROM).
1.2 About This Guide
This guide may use the terms “ICP RAID Controller,” “RAID Controller,” and “the controller” interchangeably. Each term represents the physical PCB that integrates all components of the RAID PCI add-in card.
This guide contains three sections:
Chapter 1, Getting Started
This chapter covers how to use the different user documents in the user documentation set, customer support contact information, and regulatory and license agreements covering this product.
Chapter 1.5.1, Product Regulatory Compliance
This chapter contains the procedures for installing the ICP RAID Controller into a computer system.
Chapter 3, Hardware Specifications and Features
This chapter covers all the hardware specifications associated with the ICP RAID Controller and its components and any optional RAID features that are supported by the RAID Software. The software guide covers in detail all software features.
Hardware Installation and User’s Guide 7
Getting Started
1.3 Warnings and Cautions
This guide and all associated guides in the user documentation set (see Section 1.1) should be used by qualified technical personnel with experience installing and configuring PCI controllers.
Read and adhere to all warnings, cautions, and notices in this guide and all the guides in the user documentation set supplied with this product.
Warnings
The connection of a non-shielded equipment interface cable to this equipment will invalidate the Federal Communications Commission (FCC) certification of this device and may cause interference levels that exceed the limits established by the FCC for this equipment. It is the responsibility of the user to obtain and use a shielded equipment interface cable with this device. If the equipment has more than one interface connector, do not leave cables connected to unused interfaces unless otherwise instructed to do so in the user manual.
Changes or modifications not expressly approved by the manufacturer could void the
user's authority to operate the equipment.
Cautions
Take precautions to prevent electrostatic discharge (ESD) damage before handling the
ICP RAID Controller.
ESD can damage controller components. Perform the described procedures in this
guide only at an ESD workstation. If no such station is available, you can provide some ESD protection by wearing an antistatic wrist strap and attaching it to a metal part of the computer chassis.
1.4 Customer Support Contact Information
For product support, visit http://www.icp-vortex.com or http://www.vortex.de.
1.5 Regulatory and Certification Information
1.5.1 Product Regulatory Compliance
The GDT8522RZ and GDT8622RZ RAID controllers, when correctly integrated per this guide, complies with the following safety and electromagnetic compatibility (EMC) regulations.
8 Hardware Installation and User’s Guide
Getting Started
1.5.2 Product Safety Compliance
CE - Low Voltage Directive (73/23/EEC) (European Union)
1.5.3 Product EMC Compliance
FCC Part 15, Class B Emissions (USA)
1.5.4 Product Regulatory Compliance Markings
The GDT8522RZ and GDT8622RZ RAID controllers are marked with the following regulatory markings:
1.5.5 Electromagnetic Compatibility Notices
1.5.5.1 FCC Verification Statement (USA)
Product Type: GDT8522RZ and GDT8622RZ
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
Marking Description
CE mark for European Union
Hardware Installation and User’s Guide 9
Getting Started
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
If you make any modification to the equipment not expressly approved by ICP vortex, you could void your authority to operate the equipment.
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception.
1.5.5.2 CE Declaration of Conformity (Europe)
We, ICP vortex Corporation, declare under our sole responsibility that the product:
ICP vortex GDT8522RZ and GDT8622RZ
is in conformity with all applicable essential requirements necessary for CE marking, following the provisions of the European Council Directive 89/336/EEC (EMC Directive) and Council Directive 73/23/EEC (Safety/Low Voltage Directive).
The product is properly CE marked demonstrating this conformity and is for distribution within all member states of the EU with no restrictions.
This product follows the provisions of the European Directives 89/336/EEC and 73/23/ EEC.
Dansk Dette produkt er i overensstemmelse med det europæiske direktiv 89/336/EEC & 73/23/EEC.
Dutch Dit product is in navolging van de bepalingen van Europees Directief 89/336/EEC & 73/23/EEC.
Suomi Tämä tuote noudattaa EU-direktiivin 89/336/EEC & 73/23/EEC määräyksiä.
Français Ce produit est conforme aux exigences de la Directive Européenne 89/336/EEC
& 73/23/EEC.
Deutsch Dieses Produkt entspricht den Bestimmungen der Europäischen Richtlinie 89/ 336/EEC & 73/23/EEC.
Icelandic Þessi vara stenst reglugerð Evrópska Efnahags Bandalagsins númer 89/336/ EEC & 73/23/EEC.
Italiano Questo prodotto è conforme alla Direttiva Europea 89/336/EEC & 73/23/EEC.
10 Hardware Installation and User’s Guide
Getting Started
Norsk Dette produktet er i henhold til bestemmelsene i det europeiske direktivet 89/336/ EEC & 73/23/EEC.
Portuguese Este produto cumpre com as normas da Diretiva Européia 89/336/EEC & 73/ 23/EEC.
Español Este producto cumple con las normas del Directivo Europeo 89/336/EEC & 73/ 23/EEC.
Svenska Denna produkt har tillverkats i enlighet med EG-direktiv 89/336/EEC & 73/23/ EEC.
Hardware Installation and User’s Guide 11
Hardware Installation
Hardware Installation
2
This chapter provides information on installing the GDT8522RZ and GDT8622RZ ICP RAID Controller products as well as configuring single or dual loop Fibre Channel connections. (See the Clustering Addendum in the user documentation set for information about clustering with ICP RAID Controllers).
This chapter also provides a diagram of GDT8522RZ and GDT8622RZ ICP RAID Controller product components as well as information about using components to diagnose the controller.
2.1 Installation Introduction
Review the warnings in your computer’s user manual before installing the ICP RAID Controller. You should not attempt to connect power cords to the computer on turn on the computer until ICP RAID Controller installation is complete and the computer cover is on.
Warning:
Shock hazards may be present inside the computer in which the ICP RAID controller card is being installed. Disconnect all power cords to the computer before the removal of any covers.
Note:
Take precautions to prevent electrostatic discharge (ESD) damage before handling the ICP RAID Controller card.
2.1.1 Computer System Hardware Requirements
Computer with CD-ROM drive.
Computer with one available 64-bit / 66MHz PCI slot for optimal performance.
Note:
The ICP RAID Controller is backward compatible with all 33MHz PCI expansion slots.
PCI 2.2 compliant system BIOS.
12 Hardware Installation and User’s Guide
Hardware Installation
2.1.2 ICP RAID Controller Component Layout
See Figure 2-1 for a view of the card components for the GDT8522RZ and GDT8622RZ ICP RAID Controller products.
Figure 2-1. ICP RAID Controller Component Layout (Front)
Intel® 80303
®
I/O Processor
Jumpers J
9 and J10
MIA voltage on HSSDC
LED indicators
internal data
Jumper J
2
SCSI bus termination
LED indicators loop, link
Jumper J
1
termination power
LED indicators LVD, BSY
LED indicators T, S, P
66
64-Bit / 66 MHz
universally keyed
3.3V and 5V
PCI bus interface
Audible alarm
LED indicators (FC) data, link
2Gb FC-AL HSSDC (FC) ports
FC
2
FC
1
237 mm
99 mm
Single channel Ultra160 SCSI
DIMM socket for PC133 ECC DIMM 32MB, 64MB, 128MB, 256MB
Front View
Hardware Installation and User’s Guide 13
Hardware Installation
2.2 ICP RAID Controller Installation
This section provides general instructions for installing most ICP RAID Controller cards into a standard PCI slot. (See the user manual for your workstation or server for more information about PCI card installation).
2.2.1 Installing the ICP RAID Controller Card
1. Turn off the computer system.
2. Disconnect all power cords and remove the system cover.
Figure 2-2. ICP RAID Controller Component Layout (Bracket)
2Gb FC-AL HSSDC (FC) ports
FC1 (Loop A)
Data LED for FC1
Link LED for FC1
Link LED for FC2
Data LED for FC2
FC2 (Loop B)
Loading...