ICOP ICOP-0070, ICOP-0071, ICOP-0072 User Manual

Page 1
ICOP-0070/0071/0072
Power Supply AC/DC PC/104 Module Power Supply DC/DC PC/104 Module
Power Supply DC/DC + DIO PC/104 Module
User’s Manual
(Version 3.1)
Page 2
ii
Copyright Notice
This document is copyrighted, 2000 by ICOP Technology Inc. All rights are reserved. The information in the manual is subject to change without notice in order to improving products.
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of the manufacturer.
ICOP Technology Inc. assumes no responsibility for any inaccuracies that may be contained in this document. ICOP Technology Inc. makes no commitment to update or to keep current the information contained in this manual.
Copyright 2000 by ICOP Technology Inc. All rights reserved. Ver.2.1 2000, Printed in Taiwan
Trademarks Acknowledgments
All brand names and trademarks are the properties and registered brands of their respective owners.
Page 3
iii
T a b l e o f C o n t e n t s
Chapter 0 Packing List 1 Chapter 1 Specifications 2 Chapter 2 Jumper Settings 7 Chapter 3 Connectors 8 Chapter 4 Digital I/O 9 Warranty 11
Page 4
Page 5
ICOP PC/104 Power Supply User's Manual
1
C h a p t e r 0
Packing List
Function Function Package
ICOP-0070 Power Supply
AC/DC Module
l ICOP-0070 Power Supply Module l 3 Pin extend cable x 1
ICOP-0071 Power Supply
DC/DC Module
l ICOP-0071 Power Supply Module
ICOP-0072 Power Supply
DC/DC with 24­Bit DIO Module
l ICOP-0072 Power Supply Module
Page 6
ICOP PC/104 Power Supply User's Manual
2
C h a p t e r 1
Specifications
Features ICOP-0070 Power Input voltage range : 90 ~ 264 VAC
Output voltage : +5 VDC @ 2A,
-5 VDC @ 0.2 A, +12 VDC @ 1 A,
-12 VDC @ 0.3 A Input frequency : 47 ~ 63 Hz Inrush current cold : 20A @ 110VAC, 40A @ 220 VAC Hold -up time : 16 ms Raise time: 500 ms Overload protection: power limit Short protection : auto-recovery MOSFET design Built-in line filter Meets FCC, CE, TÜV Meets UL478 and CS Fast type FUSE 2A/250V
Connector 3-pin AC input
6-pin DC output (-5V, -12V,+12V,GND,GND,+5V)
Bus Interface PC/104 standard compliant Dimensions 90 (L) x 96 (W) mm.
Weight 90 g
Operating Temperature
0 ~ +60 °C
Page 7
ICOP PC/104 Power Supply User's Manual
3
Features ICOP-0071 Power Input Voltage: +8V ~ +48V DC
Output Voltage: 5V DC / 3A Over load protection Over heat protection Converted frequency: 52 KHz Converted effect: Over 80% Suitable for auto / truck system
Bus Interface PC/104 standard compliant Dimensions 90 (L) x 96 (W) mm.
Weight 90 g
Operating Temperature
-20 ~ +60 °C
Page 8
ICOP PC/104 Power Supply User's Manual
4
Features ICOP-0072 Digital I/O 24 bit digital I/O lines (1 group)
Group emulates a 8225 PPI mode 0 Buffered circuits for higher driving capacity than 8255 Output status read back Pin -compatible with OPTO-22 I/O module racks Transfer rate: 300 KB/sec. (typical) Digital output:Logic level 0: 0.5 V max. @ 24 mA sink Logic level 1: 2.0 V min. @ 15 mA source Digital input: Logic level 0: 0.8 V max. Logic level 1: 2.0 V min.
Power Input Voltage: +8V ~ +48V DC
Output Voltage: 5V DC / 3A Over load protection Over heat protection Converted frequency: 52 KHz Converted effect: Over 80% Suitable for auto / truck system
Bus Interface PC/104 standard compliant Dimensions 90 (L) x 96 (W) mm.
Weight 110 g
Operating Temperature
-20 ~ +60 °C
Page 9
ICOP PC/104 Power Supply User's Manual
5
Component Location
ICOP-0070
ICOP-0071
L N G
CN1 AC Input
-5v / -12v / +12v / GND / GND / +5v
CN4 DC Output
CONT4 DC Input +8v~+48v
CONT5 DC Output +5v @ 3A
Page 10
ICOP PC/104 Power Supply User's Manual
6
Component Location
ICOP-0072
CONT5 DC Output +5v @ 3A
CONT4
DC Input
+8v~+48
DIO Cont
SW1
Page 11
ICOP PC/104 Power Supply User's Manual
7
C h a p t e r 2
Jumper Setting
The ICOP-0072 occupies 8 consecutive I/O locations. Dip-switch SW1 sets the base address for the ICOP-0072. Be careful when selecting the base address as some settings can conflict with existing PC ports. The following table shows common examples that usually will not cause a conflict.
Base Address Setting (SW1) (ICOP-0072)
Address 1 2 3 4 5 6
000 -00Fh ON ON ON ON ON ON 010 -01Fh ON ON ON ON ON OFF 020 -02Fh ON ON ON ON OFF ON 030 -03Fh ON ON ON ON OFF OFF 200 -20Fh OFF ON ON ON ON ON 210 -21Fh OFF ON ON ON ON OFF 300 -30Fh * OFF OFF ON ON ON ON 3F0-3FFh OFF OFF OFF OFF OFF OFF
Page 12
ICOP PC/104 Power Supply User's Manual
8
C h a p t e r 3
Connectors
Connector ICOP-0070 ICOP-0071 ICOP -0072
CONT1
AC Input
CONT2 CONT3
Digital I/O Group 1
CONT4
DC Output 8-48VDC Input 8-48VDC Input
CONT5
5VDC Output 5VDC Output
Page 13
ICOP PC/104 Power Supply User's Manual
9
C h a p t e r 4
Digital I/O
(ICOP -0072)
Mode 0 Operation
Mode 0 operation provides simple input and output operation for each of the three ports. No handshaking is required, data is simply written to or read from a specific port.
Mode 0 Basic Functional Definitions:
- Three 8-bit ports
- Any port can be input or output
- Outputs are latched
- Inputs are not latched
I/O port Assignments
Location Write Read
BASE+0 A0 A0 BASE+1 B0 B0 BASE+2 C0 C0 BASE+3 Mode Register for A0,B0,C0 N/A
8255 Data Registers
Base+0 Port A0 (read/write)
Bit 7 6 5 4 3 2 1 0
Value PA07 PA06 PA05 PA04 PA03 PA02 PA01 PA00
Page 14
ICOP PC/104 Power Supply User's Manual
10
Base+1 Port B0 (read/write)
Bit 7 6 5 4 3 2 1 0
Value PB07 PB06 PB05 PB04 PB03 PB02 PB01 PB00
Base+2 Port C0 (read/write)
Bit 7 6 5 4 3 2 1 0
Value PC07 PC06 PC05 PC04 PC03 PC02 PC01 PC00
Base+3 Port A0,B0,C0 (write)
Bit 7 6 5 4 3 2 1 0
Value 1 0 0 PA0 PCH 0 PB0 PCL
PA0 = 0 => Port A0 is output PA0 = 1 => Port A0 is input PB0 = 0 => Port B0 is output PB0 = 1 => Port B0 is input PCL = 0 => Port C0 Low Nibble is output (Bit0-3) PCL = 1 => Port C0 Low Nibble is input (Bit0-3) PCH =0 => Port C0 High Nibble is output (Bit4-7) PCH =1 => Port C0 High Nibble is input (Bit4-7)
After power -on or reset of the module the A0, B0 and C0 ports are default set to input mode.
Page 15
ICOP PC/104 Power Supply User's Manual
11
Warranty
This product is warranted to be in good working order for a period of one year from the date of purchase. S hould this product fail to be in good working orderat any time during this period, we will, at our option, replace or repair it at noadditional charge except as set forth in the following terms. This warranty doesnot apply to products damaged by misuse, modifications, accident or disaster. Vendor assumes no liability for any damages, lost profits, lost savings or anyother incidental or consequential damage resulting from the use, misuse of, orinability to use this product. Vendor will not be liable for any claim made by anyother related party. Return authorization must be obtained from the vendor before returned merchan­dise will be accepted. Authorization can be obtained by calling or faxing the vendor and requesting a Return Merchandise Authorization (RMA) number. Returned goods should always be accompanied by a clear problem description.