INSTRUCTIONS
MULTI CHARGER
BC-197
R DANGER! Charge only specified Icom battery packs with Icom chargers. Only Icom battery packs are tested and approved to be charged with Icom chargers. Charging third­party or counterfeit battery packs may cause smoke, fire, or cause the battery to burst.
R DANGER! NEVER incinerate a used bat- tery pack since internal battery gas may cause it to rupture, or may cause an explosion.
R WARNING! NEVER attempt to charge alkaline or dry cell battery packs. The BC-197 charges only Icom specified Ni-MH or Li-ion battery packs.
R WARNING!
multi charger and/or AC adapter. Incorrect reassembly may result in a fire hazard or electric shock.
USE INDOORS ONLY! NEVER expose the multi charger and the AC adapter to rain, snow or any liquids.
CAUTION: NEVER insert a battery pack
(with/without the transceiver) in a wet or soiled
condition into the multi charger. This may result in corrosion of the charger terminals or damage to the charger. The charger is not waterproof and water can easily get into it.
NEVER let metal, wire, etc. touch any inter­nal part of the multi charger.
NEVER use the multi charger or AC adapt­er when it is covered by objects which impede heat dispersion.
NEVER disassembly the
Thank you for purchasing the BC-197
m u l t i c h a r g e r . The BC-197 is designed to
charge Ni-MH or Li-ion battery packs.
Please read these instructions thoroughly before using the BC-197.
NEVER allow children to touch the multi charger. Place the charger in a secure place to avoid inadvertent use by children.
DO NOT operate the multi charger and/ or AC adapter if it has been dropped or damaged in any way. The charger or AC adapter must be inspected by an autho­rized service center in such cases.
DO NOT charge in conditions of extreme cold (under +10°C; +50°F) or extreme heat;
Ni-MH battery pack: over +35˚C; +95˚F
Li-ion battery pack: over +40˚C; +104˚F or unusual conditions like overvoltage. Otherwise, the safety/protection circuit in the charger will activate, and stop charg­ing.
Keep the charger away from TV sets or radios to prevent interference.
Make sure battery and charger contacts
are always clean; otherwise the battery packs may not properly charge.
SAVE THESE INSTRUCTIONS. These instructions contain important safety and operating details for the BC-197.
NOTE: BE SURE to disconnect the BC­157S from the AC outlet when the multi charger is not used, otherwise the radio may receive switching noise from the AC adapter, depending on the operating fre­quencies and/or antenna used.
FCC INFORMATION
This equipment has been tested and found to comply with the limits for a Class B dig­ital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful in­terference in a residential installation. This equipment generates, uses and can radi­ate radio frequency energy and, if not in­stalled and used in accordance with the instructions, may cause harmful interfer­ence to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
FCC WARNING
CAUTION: Changes or modifications not
expressly approved by the party responsi­ble for compliance could void the user's au­thority to operate the equipment.
ABOUT CE
Versions of the BC-197 which dis­play the “CE” symbol on the se­rial numb er l abel comp ly with
the essential requirements of the 2004/108/EC directive for Electromagnetic Com­patibility. This compliance is based upon the harmon­ised CENELEC generic standard EN 61000-3­2:2006/A1:2009+A2:2009, EN 61000-3-3:2008, EN61000-6-1: 2007 and EN61000-6-3: 2007.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, United Kingdom, Germany, France, Spain, Russia and/or other countries.
If this equipment does cause harmful in­terference to radio or television reception, which can be determined by turning the equipment off and on, the user is encour­aged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment 
and receiver.
•  Connect the  equipment into  an outlet on a cir­cuit different from that to which the receiver is connected.
•  Consult the  dealer or an experienced radio/TV 
technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interfer­ence received, including interference that may cause undesired operation.
SUPPLIED ACCESSORY
Item Qty.
• AC adapter (BC-157S)* ························· 1
*  Different types or no AC adapter is supplied, 
depending on the BC-197 version.
CHARGING OPERATION
(An AC adapter is
not supplied with some versions.)
AC adapter
(Connect to a DC power supply; 12 to 16 V/at least 7 A)
Red line : + Black line : _
Transceiver
Battery pack
Tu rn OFF the power
Status indicator (each indicator independently functions)
Charger adapters*1 are installed in each slot.
The shape of charger adapter depends on the version of the BC-197.
*1
DC power cable (OPC-656)
INFORMATION
q Connect the BC-157S AC adapter, or an
optional  OPC-656 DC  power cable,  to 
the BC-197, as illustrated below.
  • No status indicator lights up.
w
Insert a battery pack with (or without) the transceiver into a BC-197 charging slot.
  •  The corresponding status indicator lights up 
in orange.
STATUS INDICATOR
m Lights orange : While charging m Lights green : Cha rgi ng has com -
m Blinks red :
l
There is a problem with the inserted
battery pack and/or the charger.
l
The protector is activated (not a mal-
function) such as when;
      •  The battery  pack temperature  exceeds 
+45°C (+113˚F).
- Remove and cool down the battery pack.
pleted.
e When the status indicator changes to
GREEN, battery charging is completed.
  •  But  it is still charging in the Ni-MH battery 
pack trickle charge mode.
CAUTION: The transceiver power MUST be turned OFF during charging, otherwise;
• the battery will not be correctly charged.
• the battery life may be shortened.
NEVER transmit near the BC-197 or the AC adapter while charging.
The end of the battery pack’s working life.
      • 
- When the indicator blinks within 1 hour from the start of the charging, charge the battery pack without a transceiver or with a powered-off transceiver. In case the status indicator still blinks red, re­place it will a brand new battery pack.
When the status indicator does not light, even after a battery pack is properly in­serted, the battery pack may have a prob­lem.
There are four types of BC-197 chargers; one is for Ni-MH battery packs, and the other three are for Li-ion battery packs. Check your battery type, and then be sure to choose the suitable charger.
BC-197 Charger Type Chargeable Battery pack
With AD-120* charger adapters Ni-MH battery pack: BP-264
With AD-121* charger adapters Li-ion battery pack : BP-265
With AD-122* charger adapters Li-ion battery pack : BP-230N, BP-232N, BP-232FM
With AD-124* charger adapters Li-ion battery pack : BP-275
*  The adapter model, AD-120, AD-121, AD-122 or AD-124 is printed on the inside bottom of 
the charger adapter. On the AD-120 and AD-121, the type of battery they hold is printed 
on the top right corner of the adapter.
Charging Li-ion battery packs:
To protect the battery, BC-197 will charge a Li-ion battery pack to only about 90% of it’s fully charged capacity. Also the operating time of a transceiver with the battery pack will be shorter. If you would like to fully charge the battery pack, use the BC-193 or BC-160 instead
NOTE:
After charging has completed, the BC­197 will automatically recharge a Li-ion battery pack when the battery voltage decreases to 8 V. When the battery pack is often left in the BC-197 for long peri­ods, the battery life cycle will be short­ened.
of the BC-197.
Charging period (approximately) BP-264 : 2 hours BP-265 : 2.5 hours BP-232N : 2.5 hours BP-275 : 2.2 hours
SPECIFICATIONS
Dimensions : 303.2(W)×179.7(D)×78.2(H) mm; 11.9(W)×7.5(D)×3.1(H) in.
(projection is not included)
Weight : Approximately 1170 g; 2 lb 9 oz
Charging temperature range : +10˚C to +35˚C; +50˚F to +95˚F (Ni-MH battery pack)
Power supply requirement : 12 to 16 V DC or the specified Icom AC adapter  Charging current : 840 mA±10% (rapid charge)
All stated specifications are subject to change without notice or obligation.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan.
(with six charger adapters/without AC adapter)
+10˚C to +40˚C; +50˚F to +104˚F (Li-ion battery pack)
(BC-157S)
30 mA±15 mA (Trickle charge for Ni-MH battery pack)
A-6869H-1EX-q Printed in Japan