PRECAUTIONS
R DANGER! Charge only specified Icom
battery packs with Icom chargers. Only Icom
battery packs are tested and approved to be
charged with Icom chargers. Charging thirdparty or counterfeit battery packs may cause
smoke, fire, or cause the battery to burst.
R DANGER! NEVER incinerate a used bat-
tery pack since internal battery gas may cause
it to rupture, or may cause an explosion.
R WARNING! NEVER attempt to charge
alkaline or dry cell battery packs. The
BC-197 charges only Icom specified Ni-MH
or Li-ion battery packs.
R WARNING!
multi charger and/or AC adapter. Incorrect
reassembly may result in a fire hazard or
electric shock.
USE INDOORS ONLY! NEVER expose
the multi charger and the AC adapter to
rain, snow or any liquids.
CAUTION: NEVER insert a battery pack
(with/without the transceiver) in a wet or soiled
condition into the multi charger. This may
result in corrosion of the charger terminals
or damage to the charger. The charger is
not waterproof and water can easily get
into it.
NEVER let metal, wire, etc. touch any internal part of the multi charger.
NEVER use the multi charger or AC adapter when it is covered by objects which
impede heat dispersion.
NEVER disassembly the
Thank you for purchasing the BC-197
m u l t i c h a r g e r . The BC-197 is designed to
charge Ni-MH or Li-ion battery packs.
Please read these instructions thoroughly
before using the BC-197.
NEVER allow children to touch the multi
charger. Place the charger in a secure
place to avoid inadvertent use by children.
DO NOT operate the multi charger and/
or AC adapter if it has been dropped or
damaged in any way. The charger or AC
adapter must be inspected by an authorized service center in such cases.
DO NOT charge in conditions of extreme
cold (under +10°C; +50°F) or extreme
heat;
Ni-MH battery pack: over +35˚C; +95˚F
Li-ion battery pack: over +40˚C; +104˚F
or unusual conditions like overvoltage.
Otherwise, the safety/protection circuit in
the charger will activate, and stop charging.
Keep the charger away from TV sets or
radios to prevent interference.
Make sure battery and charger contacts
are always clean; otherwise the battery
packs may not properly charge.
SAVE THESE INSTRUCTIONS. These
instructions contain important safety and
operating details for the BC-197.
NOTE: BE SURE to disconnect the BC157S from the AC outlet when the multi
charger is not used, otherwise the radio
may receive switching noise from the AC
adapter, depending on the operating frequencies and/or antenna used.
FCC INFORMATION
This equipment has been tested and found
to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will
not occur in a particular installation.
FCC WARNING
CAUTION: Changes or modifications not
expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
ABOUT CE
Versions of the BC-197 which display the “CE” symbol on the serial numb er l abel comp ly with
the essential requirements of the
2004/108/EC directive for Electromagnetic Compatibility.
This compliance is based upon the harmonised CENELEC generic standard EN 61000-32:2006/A1:2009+A2:2009, EN 61000-3-3:2008,
EN61000-6-1: 2007 and EN61000-6-3: 2007.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United
States, United Kingdom, Germany, France, Spain, Russia and/or other countries.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV
technician for help.
This device complies with Part 15 of the
FCC Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
SUPPLIED ACCESSORY
Item Qty.
• AC adapter (BC-157S)* ························· 1
* Different types or no AC adapter is supplied,
depending on the BC-197 version.

CHARGING OPERATION
(An AC adapter is
not supplied with
some versions.)
AC adapter
(Connect to a DC power supply; 12 to 16 V/at least 7 A)
Red line : + Black line : _
Transceiver
Battery pack
Tu rn OFF the power
Status indicator
(each indicator independently functions)
Charger adapters*1 are
installed in each slot.
The shape of charger adapter depends
on the version of the BC-197.
*1
DC power cable (OPC-656)
INFORMATION
q Connect the BC-157S AC adapter, or an
optional OPC-656 DC power cable, to
the BC-197, as illustrated below.
• No status indicator lights up.
w
Insert a battery pack with (or without) the
transceiver into a BC-197 charging slot.
• The corresponding status indicator lights up
in orange.
STATUS INDICATOR
m Lights orange : While charging
m Lights green : Cha rgi ng has com -
m Blinks red :
l
There is a problem with the inserted
battery pack and/or the charger.
l
The protector is activated (not a mal-
function) such as when;
• The battery pack temperature exceeds
+45°C (+113˚F).
- Remove and cool down the battery
pack.
pleted.
e When the status indicator changes to
GREEN, battery charging is completed.
• But it is still charging in the Ni-MH battery
pack trickle charge mode.
CAUTION: The transceiver power MUST
be turned OFF during charging, otherwise;
• the battery will not be correctly charged.
• the battery life may be shortened.
NEVER transmit near the BC-197
or the AC adapter while charging.
The end of the battery pack’s working life.
•
- When the indicator blinks within 1 hour
from the start of the charging, charge
the battery pack without a transceiver or
with a powered-off transceiver. In case
the status indicator still blinks red, replace it will a brand new battery pack.
When the status indicator does not light,
even after a battery pack is properly inserted, the battery pack may have a problem.
There are four types of BC-197 chargers; one is for Ni-MH battery packs, and the other
three are for Li-ion battery packs.
Check your battery type, and then be sure to choose the suitable charger.
BC-197 Charger Type Chargeable Battery pack
With AD-120* charger adapters Ni-MH battery pack: BP-264
With AD-121* charger adapters Li-ion battery pack : BP-265
With AD-122* charger adapters Li-ion battery pack : BP-230N, BP-232N, BP-232FM
With AD-124* charger adapters Li-ion battery pack : BP-275
* The adapter model, AD-120, AD-121, AD-122 or AD-124 is printed on the inside bottom of
the charger adapter. On the AD-120 and AD-121, the type of battery they hold is printed
on the top right corner of the adapter.
Charging Li-ion battery packs:
To protect the battery, BC-197 will
charge a Li-ion battery pack to only
about 90% of it’s fully charged capacity.
Also the operating time of a transceiver
with the battery pack will be shorter. If
you would like to fully charge the battery
pack, use the BC-193 or BC-160 instead
NOTE:
After charging has completed, the BC197 will automatically recharge a Li-ion
battery pack when the battery voltage
decreases to 8 V. When the battery pack
is often left in the BC-197 for long periods, the battery life cycle will be shortened.
of the BC-197.
Charging period (approximately)
BP-264 : 2 hours
BP-265 : 2.5 hours
BP-232N : 2.5 hours
BP-275 : 2.2 hours
SPECIFICATIONS
Dimensions : 303.2(W)×179.7(D)×78.2(H) mm; 11.9(W)×7.5(D)×3.1(H) in.
(projection is not included)
Weight : Approximately 1170 g; 2 lb 9 oz
Charging temperature range : +10˚C to +35˚C; +50˚F to +95˚F (Ni-MH battery pack)
Power supply requirement : 12 to 16 V DC or the specified Icom AC adapter
Charging current : 840 mA±10% (rapid charge)
All stated specifications are subject to change without notice or obligation.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan.
(with six charger adapters/without AC adapter)
+10˚C to +40˚C; +50˚F to +104˚F (Li-ion battery pack)
(BC-157S)
30 mA±15 mA (Trickle charge for Ni-MH battery pack)
A-6869H-1EX-q Printed in Japan