Intelligent Cabinet Interface to Traffic Equipment
iCITE® DA-Data Aggregator®
DA-400™
Installation and Operations Manual
THIS MANUAL CONTAINS IMPORTANT INSTALLATION INSTRUCTIONS
REVISION: 03 July 2019
Version 1.0
888-0400-001
EBERLE DESIGN INC., PHOENIX, ARIZONA, UNITED STATES OF AMERICA.
iCITE®, iCITE READY®, iCITE G2®, DA-400™, DA-Data Aggregator® ARE
REGISTERED TRADEMARKS OF EBERLE DESIGN INC. AND MAY NOT BE USED OR
REPRODUCED BY ANY PARTY. INFORMATION CONTAINED HEREIN IS
PROPRIETARY TECHNICAL INFORMATION OF EBERLE DESIGN INC. PUBLICATION,
REPRODUCTION OR USE IN WHOLE OR PART IS NOT PERMITTED EXCEPT UNDER
TERMS AGREED UPON IN WRITING FROM EBERLE DESIGN, INC.
Information in this document is subject to change without notice and does not represent a
commitment on the part of EDI. EDI provides this document as is, without warranty of any
kind, either expressed or implied, including, but not limited to, its particular purpose. EDI
reserves the right to make improvements and/or changes to this manual, or to the products
and/or the programs described in this manual, at any time. Information provided in this
manual is intended to be accurate and reliable. However, EDI assumes no responsibility for
its use, or for any infringements on the rights of third parties that may result from its use.
This product might include unintentional technical or typographical errors. Changes are
periodically made to the information herein to correct such errors, and these changes are
incorporated into new editions of the publication. Please visit the EDI website at
http://www.EDItraffic.com/
revision of this manual.
iCITE® IS DESIGNED AND MANUFACTURED BY
EDI IS CERTIFIED TO ISO 9001:2015 QUALITY STANDARDS.
U.S. Pat. No. 10,210,753
Disclaimer
or contact EDI Sales or Technical Support to obtain the latest
5.1 Repairs and Servicing ...........................................................................................40
5.2 No Central Light (Dark) .........................................................................................40
5.3 No HEART LED (Dark) ..........................................................................................40
5.4 No Cellular Connection .........................................................................................41
5.5 LED Display Blank.................................................................................................41
5.6 No GPS Information ..............................................................................................41
5.7 No Wi-Fi Travel Time Information ..........................................................................41
5.8 No Cabinet Data Information .................................................................................41
5.9 No Bluetooth Travel Time Information ...................................................................42
5.10 Unable to connect to Data Aggregator via Ethernet Connection ..........................42
Table of Contents
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
Section 1 INTRODUCTION
1.1 OVERVIEW
Thank you for selecting the EDI Data Aggregator, DA-400™ to address your remote
intersection connectivity, VPN, and traffic data collection requirements. This manual is
provided to give you the information needed to conduct a successful installation of the DA400™ into a traffic signal controller cabinet. This device will work with all North American
cabinet types and controller manufacturers, and will also work with many international
controller and cabinet types. Depending on the type of cabinet in which the Data
Aggregation device is installed, there will be some wires within the harness that will not
need to be connected. Those wires can be removed from the iCITE
harnesses if desired and stored for potential later installation and utilization if needed.
®
The iCITE
DA-400™ is designed to provide comprehensive information about the
operational health and status of the traffic control cabinet and to allow remote
communications and connectivity from the traffic controller cabinet and its associated
components to an iCITEREADY
and web-based configuration software is called iCITE G2to Traffic Equipment), and is capable of communicating with as many units as are
installed and connected to the system. This iCITE G2
®
Web-based user interface and display. The local unit
®
(Intelligent Cabinet Interface
®
is accessible through an
administrator-issued user name and password, wherever there is internet connectivity
available. Information provided through the local Ethernet interface, the cellular connection
and on iCITE G2
®
can be viewed on any browser; however, Google Chrome is the web
browser recommended. The DA-400™, along with an iCITE READY
partner, is also capable of collecting and transmitting the raw data needed to provide
comprehensive travel time information and route analytics. VPN capabilities and the ability
to act as a replacement for an On-Street Master are also provided. This manual will provide
a step-by-step process of installing, connecting and configuring the DA-400™ and its
associated wiring harnesses into the traffic cabinet. There is also a required 5-band
antenna that will need to be installed and connected onto the top exterior of the traffic
cabinet.
®
DA-400™ wiring
®
data analytics
Figure 1 DA-400 Front Panel View, Connections
Eberle Design Inc. Page 1
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
Figure 2 DA-400 Rear Panel View, Connections
Eberle Design Inc. Page 2
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
Section 2 HARDWARE
2.1 HARDWARE REQUIREMENTS
The hardware required for installation consists of the following: A DA-400™, two (2)
harnesses, H5 and H7 and a 5-band antenna. The DA-400™ is designed to be shelf
mounted and will have one (1) mounting ear for left or right side rail mount installation into a
standard 19-inch EIA rack type cabinet. Several tools will be required for installation of the
DA-400™ depending on your chosen and required installation configuration. In each type of
potential installation, cabinet wiring will be terminated in different locations and in potentially
different configurations. It will be up to the end user agency to determine the correct
locations based on the implemented cabinet designs and the desired connectivity
functionalities.
For those Agencies requiring specification assistance, please contact EDI for additional
information and implementation guidance. See the contact information in Troubleshooting
Section 5 of this manual.
2.2 TOOLS
The tools required for a typical traffic cabinet installation are:
● Flat Head Screwdriver
● Phillips #1 Screwdriver
● Phillips #2 Screwdriver
● Wire Cutters
● Wire Strippers
● Wire Crimpers
● Digital Multi-meter
● Stepped Hole Bit – up to 1 inch (Antenna Mounting Hole is ½”)
● Drill
● Assorted tie wraps
The following pictures represent the hardware that will be installed, optional equipment
shown is the antenna bracket to mount antenna bracket on the side of a cabinet. The two
harnesses and rack mounting ear are not shown.
Eberle Design Inc. Page 3
iCITE® DA-Data Aggregator® DA-400™ and
Installation Manual
Figure 3 Optional Side Mount Antenna Mounting Bracket
NOTE: The DA-400™ is ready to install out of the box.
iCITE
®
Figure 4 DA-400 Front and Back Panel View
Eberle Design Inc. Page 4
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
Section 3 INSTALLATION
3.1 PREPARING FOR INSTALLATION
To begin the installation, unpack all the equipment for installation. Ensure you have all the
tools and materials required to complete the installation. The tools are listed in paragraph
2.2 Tools. The cabinet does not have to be in flash, and the DA-400™ is designed to be
installed while the intersection is running if the user takes all appropriate IMSA and MUTCD
recommended safety precautions. Follow all applicable and appropriate State DOT/local
agency rules and procedures for working in an operational Traffic Control Cabinet, with the
potential of creating a fault condition that could cause a flash condition in the cabinet.
Different administrative agencies will have different guidelines and requirements up to and
including having a Law Enforcement Officer on-site for traffic control in the event of a traffic
signal cabinet service interruption. Preparations should be made to correctly identify and
note the locations of all field wiring terminations, before the DA-400™ wiring harnesses
installation begins.
CAUTION: Care should be taken to make sure that critical 24 VDC and 120 VAC are
not disturbed or disrupted, or the cabinet may potentially go into a flash, failure or
fault condition.
3.2 PLACING THE DA-400™ INTO THE CABINET
Determine where the DA-400™ will be placed in the cabinet. It may be located anywhere in
the cabinet there is space available for the unit. The floor of the cabinet should be avoided
due to the potential for water intrusion. The unit should be placed in a location allowing air
to circulate freely around it. The leads for all wire harnesses are 8 feet (2.4 meters) in
length so the position of the DA-400™ should be located such that all required connections
can be terminated based on its position inside the traffic control cabinet. Once a location is
established, the DA-400™ can be placed on the shelf, or mounted on the side rail of the
rack assembly. A mounting ear is supplied. Screw the mounting ear onto the DA-400™
attach the device to the side of the equipment rack.
3.3 CONNECTING THE DA-400™ HARNESSES
Once the DA-400™ is placed into the cabinet, the next step will be to wire in the two (2)
connection harnesses. Each harness has a different sized connector pin-out and wire color
code to prevent cross wiring. Each wire is also marked with printed lettering to indicate the
specific function of the wire and its associated monitoring termination point. These marks
provide information to where the wires need to be terminated within the cabinet. The
harnesses are labeled: H5 and H7. The following is the wiring information for each harness.
and
Not all the connections on each harness will be connected on every installation. For
example, if there is no Battery Backup System (BBS) in the cabinet, none of these wires
will have a place to be connected. All unused wires should be looped and tied back.
CAUTION: DO NOT CUT BACK HARNESS WIRES. Leave wiring intact for possible
future installation.
CAUTION: Do not plug the harnesses into the DA-400™ until all terminations are
completed. It is also good practice to make sure the correct voltages are on each
wire before connecting the harness to the DA-400™. All AC voltages are for 120 VAC
connections.
Eberle Design Inc. Page 5
iCITE® DA-Data Aggregator® DA-400™ and
DA-500E H-5 (Digital DC Inputs)
RANGE
RANGE
Pin
A1
DETECTOR9
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 9
A2
DETECTOR10
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 10
A3
DETECTOR11
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 11
A4
DETECTOR12
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 12
A5
DETECTOR13
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 13
A6
DETECTOR14
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 14
A7
DETECTOR15
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 15
A8
DETECTOR16
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF2
Input from detector
output 16
A9
VREF2
RED
12 OR 24
0-62 VDC
Reference pull up
16
A10 - -
(internally connected to
logic gr ound
A11
PED3
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF3
Input from Ped Isolator 3
A12
PED4
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF3
Input from Ped Isolator 4
B1
DETECTOR1
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 1
B2
DETECTOR2
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 2
B3
DETECTOR3
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 3
B4
DETECTOR4
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 4
B5
DETECTOR5
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 5
B6
DETECTOR6
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 6
B7
DETECTOR7
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 7
B8
DETECTOR8
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF1
Input from detector
output 8
B9
VREF1
RED
12 OR 24
VDC
0-62 VDC
Reference pull up
voltage for Ped 1-4
B10
VREF3
RED
12 OR 24
VDC
0-62 VDC
Reference pull up
voltage for Detectors 1-4
B11
PED1
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF3
Input from Ped Isolator 1
B12
PED2
BLUE
0-28 VDC
0-120 VDC
2.5, 3, 6, 12 V
VREF3
Input from Ped Isolator 2
Table 1 H-5 Harness Inputs
iCITE
®
Installation Manual
Pin
WIRE
MARKING
WIRE
COLOR
TYPICAL
VOLTAGE
VDC
MAXIMUM
VOLTAGE
THRESHOLD
Pull up
Power
voltage for Detectors 9-
FUNCTION
NOTE1: Digital inputs are voltage based, and are referenced to the Logic Ground provided
on H7.
NOTE 2: Typical input impedance is 150K Ohm.
NOTE 3: Each input pin can have a pull-up resistor connected by applying a pull-up voltage
(typically 12VDC or 24VDC) to the associated Pull up VREF pin.
Eberle Design Inc. Page 6
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
Figure 5 Typical Digital DC Input
Figure 6 H-5 Connector / Detector inputs
Figure 7 H-7 Connector Inputs
Eberle Design Inc. Page 7
iCITE® DA-Data Aggregator® DA-400™ and
DA-500E H-7 (Analog Inputs/Relay)
Pin
WIRE
WIRE
RECOMENDED
MAXIMUM
DAMAGE
FUNCTION
A1
ANALOG DC 1
BLUE
0-30 VDC
0-42 VDC
Typically used to measure Stop
Time signal level
A2
ANALOG DC 3
BLUE
0-30 VDC
0-42 VDC
Typically used to measure the
voltage on the BBS status output
A3
ANALOG DC 5
BLUE
0-30 VDC
0-42 VDC
Typically used to measure the
+12VDC cabinet voltage
A4
ANALOG DC 7
BLUE
0-30 VDC
0-42 VDC
power)
Analog DC in 7
ATO)
A5
LOGIC GROUND
BLACK
Cabinet Logic Ground connection
A6
COM1/
SOURCE1
BROWN
Relay Common connection
A7
NO1/DRAIN1
VIOLET
0-300 VAC
0-30 VDC
Relay Normally Open connection
A8
ANALOG AC 3
YELLOW
0-240VAC
0-300VAC
Typically used to measure the
Heater
A9
ANALOG AC 5
YELLOW
0-240VAC
0-300VAC
Typically used to measure the Door
Switch Voltage
A10
ANALOG AC 7
YELLOW
0-240VAC
0-300VAC
User defined AC input signal
B1
ANALOG DC 2
BLUE
0-30 VDC
0-42 VDC
Typically used to measure the
Battery Backup System Battery
B2
ANALOG DC 4
BLUE
0-30 VDC
0-42 VDC
Typically used to measure the
signal level for cabinet Flash
B3
ANALOG DC 6
BLUE
0-30 VDC
0-42 VDC
Typically used to measure the
Batt signal.
B4
Temperature
BLUE
0-5 VDC(temp sensor
input)
0-30 VDC
Temperature sensor +
B5
Temp Sense -
BLACK
Temperature sensor -
B6
EARTH GROUND
GREEN
Earth Ground to the cabinet
B7
ANALOG AC 2
YELLOW
0-240VAC
0-280VAC
Typically used to measure Battery
Backup AC line
B8
ANALOG AC 4
YELLOW
0-240VAC
0-280VAC
Typically used to measure the
Cabinet Fan Voltage
B9
ANALOG AC 6
YELLOW
0-240VAC
0-280VAC
User defined AC input signal
B10
ANALOG AC 8
YELLOW
0-240VAC
0-280VAC
User defined AC input signal
iCITE
®
Installation Manual
MARKING
Sensor
COLOR
VOLTAGE
RANGE
(8-28 VDC for power)
(0-24 VDC as analog
VOLTAGE
WITHOUT
(5-30 VDC for
DC Input (FC1 installed 1.25A
Voltage applied to the Cabinet
voltage on the positive lead of the
voltage on the Battery Backup on
(Analog DC input 8)
NOTE 1: The AC input voltages are all referenced to the “AC NEUTRAL” connection, and
are Isolated from the Logic ground. If the AC NEUTRAL wire is not connected, the
measured voltages will be incorrect.
NOTE 2: DC measurements referenced to AC NEUTRAL may also be made.
NOTE 3: AC1 (CAB AC LN) is used to measure the frequency of oscillation for cabinet.
NOTE 4: Typical input impedance is 202K Ohm.
NOTE 5: All DC inputs are referenced to LOGIC GND.
After wiring all the associated, active connections and testing them for proper voltages, the
DA-400™ can then be powered up. The Input Power connector should be plugged into the
unit first. A LED on the front panel (POWER) should light up. This indicates that the unit is
Eberle Design Inc. Page 8
Table 2 H-7 Harness Inputs
iCITE® DA-Data Aggregator® DA-400™ and
1
2
3
4
5
2.6
2.0
.49 in
11/16 in.
.84 in.
.5 in
Lead 1 – GPS – 1575.42 MHz – SMA-M
Lead 2 – Cell – Varies – SMA-M
Lead 3 – Wi-Fi – 2.4 GHz – SMA-RP
Lead 4 – B lueTooth – 2.4 GH z – SMA-M
Lead 5 – DS RC – 5.9 GHz – SMA-M
iCITE
®
Installation Manual
powered and that the processor and functionality is operational for the DA-400™. The other
connectors can now be attached. No specific or particular connection order is required.
3.4 INSTALLING THE DA-400™ ANTENNA / ANTENNA ASSEM BLY
The next step is to install the 5-band antenna and Radome assembly. Now that the location
for the DA-400™ has been established determine where the antenna will need to be
mounted. If the antenna will be mounted on top of the cabinet use a step-down drill bit to
drill the desired size hole to feed the mounting bolt through. For the 5-band antenna it will
need to be a 1/2 in. (12.7mm) feed through hole. Feed the cables through the hole. Take
care to ensure that no rough edges on the drilled hole cut the antenna cable shielding.
Place the Radome firmly onto the cabinet. A small amount of silicone adhesive can be used
to ensure a better seal. Then thread the cables through the provided cut out nut and
washer inside the cabinet. Tighten the nut to secure the antenna Radome. Care should be
taken to not drop the nut or washer inside the operational cabinet and ensure the antenna
has been located in a position where the threaded connection will be accessible to your
hand to place the nut and washer and have adequate room to use a wrench to tighten the
nut. Pay special attention to any internal cabinet “voids” where metal has been folded and
the antenna mount will not penetrate fully. Metal Epoxy Putty can be used if need to repair
unwanted cabinet penetrations. It is recommended to utilize a cardboard box inside the
cabinet to capture any metal drill shavings and prevent potential wiring shorts inside the
cabinet. Drilling from the outside in provides an opportunity to capture the drill shavings.
If the Radome cannot be mounted to the top of the cabinet a side mounted bracket is
available for purchase. The feed hole will be drilled in the side of the cabinet and the
bracket will be mounted to the side of the cabinet, where the mounting ears are located, if
there are detachable mounting ears. Otherwise two smaller holes will need to be drilled for
the attachment bolts.
Once the antenna assembly is mounted, connect the GPS and the Cell leads to the DA400™. Each lead will be marked accordingly and will be found next to the SMA connector.
At this time, the DSRC and Bluetooth leads can be left disconnected. It is recommended
they are looped and tie-wrapped in an inconspicuous location inside the cabinet for future
use.
After the GPS and the cellular antenna are attached there will be a second indications on
the front of the DA-400™. The LED marked HEART may take several minutes to light up,
but once it lights up will it will begin to flash.This is the indication that the Cellular modem
has connected to the cloud based software, and reported the location of the DA-400™.
NOTE: The Antenna Radome Assembly and Harness Assemblies are sold separately.
Eberle Design Inc. Page 9
Figure 8 Five-Band Antenna
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
Figure 9. Five-Band Antenna Specifications.
Eberle Design Inc. Page 10
iCITE® DA-Data Aggregator® DA-400™ and
iCITE
®
Installation Manual
3.5 INSTALLING THE CELLULAR SIM CARD INTO THE DA-400™
The DA-400™ is shipped to the customer with no SIM card populating the SIM Card
Holder. To install the SIM card, the rear access plate must be detached from the unit by
removing the (5) screws on the back of the DA-400™ unit. Once removed, the unit will look
like this:
Figure 10. SIM Card Slot - Depopulated.
Figure 11. SIM Card Slot - Populated.
Insert the SIM card into the slot using the orientation shown in the picture. The SIM Card
must be industrial rated to guarantee continuous, uninterrupted operation in a NEMA
Cabinet operating across a wide operating temperature and humidity range.
3.6 CONNECTING A NEMA TS-2 TYPE 2 SDLC TO THE DA-400™
If the DA-400™ is being installed into a NEMA TS-2 Type 2 cabinet, there is additional
information that is relayed to the iCITE G2® software. This is through the SDLC
communications of the TS-2 Type 2 cabinet. If there is an existing spare SDLC cable it can
simply be plugged into the front of the DA-400™. No additional programming in the
controller is necessary. If there is not a spare SDLC cable, one could be installed, or the
DA-400™ could be connected in serial on an existing SDLC connection using the two
provided SDLC connections on the front of the DA-400™ and two SDLC Cables. Prior to
disconnecting the SDLC from the detector BIU, it is advisable to pull the BIU from the rack.
Alternatively, depending on the controller and the capabilities of the installer, you may be
able to “deactivate” the BIU SDLC bus from within the Controller’s programming menu.
Eberle Design Inc. Page 11