ICHRoboter iCleaner-200D User Manual

200D
1 Safety Warnings
Please read this manual carefully before using the iCleaner-200D.
- 1 -
Before performing maintenance or service on the iCleaner-200D please ensure the power is disconnected to avoid personal injury or property loss.
Do not swim in the pool whilst the iCleaner-200D is in use in order to avoid personal injury.
Do not allow the Power Box to come in contact with water, and it is recommended to be placed in a shady, dry and ventilated area.
When in use, the Power Supply and Caddy Cart must remain 3 meters away from the edge of the pool.
Do not use the iCleaner-200D if there is a chance of thunder storm to avoid personal injury.
Users are only permitted to perform maintenance described in this manual. Any tampering with the Motor Box or Power Supply will void the warranty.
Ensure the iCleaner-200D is fully submerged before turning the power box on.
If the iCleaner-200D is not going be used for a long time, make sure to disconnect the power, keep it clean and put it in a safe, dry and well- ventilated area.
If the iCleaner-200D stops working, please refer to
t local distributor.
The optimum working temperature for the iCleaner-200D is between10 and 32, avoid direct sunlight when not in use.
The iCleaner-200D is suitable for the swimming pools no deeper than 3 meters.
Lift the iCleaner-200D out of the water using the robot handles, do not lift the iCleaner using the floating cable. Lifting via the cable voids warranty.
section 6
Troubleshooting. If you cannot find the root cause, please contact your
2 Product Overview
2.1 Functions
2.2 Product Parameters
iCleaner-200D 100~240VAC, 50-60Hz
350W 4Hrs/6Hr /8Hrs s 40m
3
40m /h 15m/min
Host: IP68
Model Input Voltage Rated Power Cycle Time Floating Cable Standard Length Filter Bag Water Pump Capacity Moving speed
Storage Temperature Optimum Working Temperature
DimensionL*W*H
Grade of Waterproof
- 2 -
Standard: 70um
10~32
0~40
845.8*264*452.5mm
Gross Weight
931*574*433mm
Packing Measurement(L*W*H)
37.5kg
Automatic cleaning: the default mode is automatic, however, this can be overridden using the
Remote Control. When the Remote Control is not being used, the iCleaner-200D will return to automatic mode.
Overall cleaning: the iCleaner-200D not only cleans the floor of your pool, it also cleans the
wall, at the same time, the iCleaner-200D will filter water, and the dirt will be collected into Filter Bag.
Timing cleaning: you can select one of three cleaning time with Remote Control (4h, 6h or 8
h). The iCleaner-200D will shut down automatically when the selected cycle time is over. The power box must be turned of manually.
Manual cleaning: the Remote Control can be used to clean specific areas immediately. Self protection (out of water): Impeller decelerates to a stop in twenty five seconds if the
iCleaner-200D senses it is no longer in water, to prevent personal injury and to protect the water pump.
Stop protection: the iCleaner-200D will stop if foreign matter retards the Impeller.
2.3 Parts List
Main Body Parts
Guide Vane
Pic.2.3.2
- 3 -
Drive Be lt
Wate r Jo int
Filter N et
Water Reta ni ng Boar d
Base Pla te
Suppor t Fr ame
Filter B ag
Base Pla te L atch
Motor Bo x
Power Box Parts
- 4 -
1
2
2
9
10
11
Floating Cable
Impeller
Filter Bag
Pic.3.2.1
- 5 -
1
1
1
1
2
1
1
1
1
2
3
4
5
6
7
8
3 Packing List
Part Name
Unit Body
Power Box
Remote Control
Battery
Guide Vane
User Manual
Warranty Card
Certificate of Quality
Serial Number
Remarks
Host
Quantity
1 0
1 1
1
Spare Parts
4 Product Operation
4.1 Power Connection
(Pic.4.1.1) (Pic.4.1.2)
- 6 -
Please connect the Floating Cable to the Cable Socket of Power Box (see Pic.
4.1.1), then connect the Power Box to an outside AC power of 100v/240v 50/60Hz (see Pic.4.1.2). For the complete connection guide please refer Pic.4.1.3
Notices: Do not allow the Power Box to come in contact with water.
Please ensure the Power Box is Kept in a shady, dry & ventilated area.(Refer Page 1.Safety Warning)
Pic.4.2.1
Pic.4.2.2
- 7 -
4.2 Start Up Procedure
(1) When placing the iCleaner-
200D in the pool: you must wobble the iCleaner-200D according Pic.4.2.1 to make sure the air inside is released when you put the iCleaner­200D in the water,
So it will automatically sink to
the bottom of pool.
(2) Start: Press the “ON” button,
LED “POWER” indicator. And “4H” cycle time LED will illuminate(see pic.4.2.2)
You may select 4Hrs, 6Hrs or
8Hrs cleaning time using the button on the Remote Control and relative LED indicators will illuminate on the Power Box when selected.
OPE N
OPE N
Bott om Bu tton
4
6
4.3 Proper Shut Down and Care
(1) To Shut Down The iCleaner-200D: Turn the power switch on the power Box to the off position, once the iCleaner­200D finishes working, pull the Floating Cable slowly until the Handle emerges from the water (Pic.4.3.1), and then pull the iCleaner-200D out of the pool by its Handle.
(2) Clean iCleaner-200D: Invert the iCleaner-200D gently onto the floor, unlock the Latch on the Base Plate (Pic4.3.2) and remove the Filter Bag from Base Plate, clean the Filter Bag (Pic.4.3.3), once clean place the Filter Bag on its frame, reassemble the Base Plate and put it back into the iCleaner-200D once the Filter Bag is dry.
(Note: When re-fitting the Filter Bag to the Base Plate, please ensure the long sides of the Filter Bag are smooth to ensure an easy fit into the base of the iCleaner-200D.)
- 9 -
(3) iCleaner-200D Storage: When the iCleaner-200D is dry,disconnect the floating cable reel it in hand-over-hand and place on the iCleaner-200D, then store the iCleaner-200D in a dry,well-ventilated area. If you have the Caddy , please put the iCleaner-200D & Floating Cable on to the Caddy Cart, details please refer Pic.4.3.4
Pic.4.4.1
Floor On ly C leaning
The Remote Control (Pic.4.4.1) includes: On/Off Power Button LED Light Indicator Direction Button Timer Button Floor Only Cleaning
On/Off Power Button:
Turn on or Turn off iCleaner-200D
Direction Button:
Control iCleaner-200D's movement Backward , Left Rotation and Right
Rotation
Timer Button :
Select the timing mode from 0.5hour, 1 hour and 2hours
Floor Only Cleaning : To clean the “Floor Only ” press . To return to floor and wall cleaning, turn the
iCleaner-200D off, then on using the remote contorl .
4.5 Water Joint
- 10 -
Step 2 Screw down the Lock Nut clockwise. (Pic.4.5.2)
Pic.4.5.2
Step 1 Insert water joint into iCleaner-200D. (Pic.4.5.1)
Water Joint
5 Maintenance
5.1 Impeller
- 11 -
Guide Vane
Change the Impeller if the old one gets worn or damage
Step 1: R o t at e G ui d e Va ne clockwise to remove from the iCleaner-200D.(Pic.5.1.1)
Step 2 Use a Phillips head screw driver to remove the bolt in the Impeller according the diagram.(Pic.5.1.2)
Step 3 Replace the new Impeller and assemble Impeller and Guide Vane
5.2 Sponge Wheel
- 12 -
Pic.5.2.2
Replace the Sponge Wheels if they are badly worn or broken
Step 1 Invert the iCleaner-200D on the floor, remove the Base Plate.(Push latch to unlock the Base Plate).(Pic.5.2.1)
Step 2 ※ Remove the Filter Net from the iCleaner-200D while pressing the Latch according to the diagram.(Pic.5.2.2)
Step 3 Using a Phillips head screwdriver and 7mm ring spanner undo the six bolts and nuts on the Side Cover,to remove the Side Cover. ( Pic.5.2.3)
Step 4 Remove the Rolling Brush. (Pic.5.2.4)
- 13 -
Pic.5.2.3
Pic.5.2.4
Step 6 Assemble the Rolling Brush to the axle (Pic.5.2.6) .
Step 5 Slide the old sponge wheels off, and replace w i t h n e w s p o n g e wheels(Pic.5.2.5)
Pic.5.2.5
14
Step 8 Fasten the transmission components and side covers to the body of the unit using the nuts and bolts (Pic.5.2.8)
- 15 -
Pic.5.2.7
Pic.5.2.8
step 7
(Pic.5.2.7)
Reassemble the Transmission
components and side covers to the body of the unit
Step 9 ※ Put the filter Net into the iCleaner-200D,press down on the filter net until the Latch locks into the bracket. (Pic.5.2.9)
Step 10 ※ Place the base Plate into iCleaner-200D, pressing down until the latches lock into place (Pic.5.2.10)
※ Replacing the sponge wheels is now complete.
Pic.5.2.9
Pic.5.2.10
5.4 Filter Bag
Pic.5.4.1 Filter Bag is full
- 16 -
5.3 Water Retaining Board
Replace the Water Retaining Board if they are broken(Pic 5.3.1)
hole
When the Filter Bag is dirty as shown in pic. 5.4.1 or if the Filter Bag has been damaged, please refer to chapter 4.3.2 to replace Filter Bag.
Pic.5.3.1 Replace the water retaining board
Step 1 Remove the base plate from the iCleaner and remove the filter bag, then open the water retaining board to the vertical position and carefully slide the water retainining board to one end, remove the water retainining board carefully.
Step 2 Insert one end of the water retaining board into the locating holes on the base plate, then insert the other end of the water retaining board into the base plate, and make sure the water retaining board does not have a bend in it(if it does, gently push the hinged edge,until it clicks into position). Note: The water retaining board is fitted correctly, please refer to pic.5.3.2
Pic.5.3.2
6 Troubleshooting and Warning Lights
Commonfault
Reason
Solution
Remarks
iCleaner-200D doesn't work
Weak pumping
iCleaner-200D is turning to one side when it moves
iCleaner-200D will not climbs wall
iCleaner-200D will not sink to the bottom of the pool
Dirt is coming through the guide vane.
The socket is not plugged in
Connection is wrong
Impeller is jammed or dirty
Impeller is damaged
Filter Bag is full
Drive Belt is loosen or broken at one side
The Filter Bag is full
The Filter Bag is full
Drive Belt is loosen or broken
Sponge wheel wear
axis sleeves wear
The sponge wheel don't soak enough
It has air inside the machine
Belt of Filter Bag is loosen or broken. Dirt is too fine for the filter bag
Plug in the power lead
Check the connection
clean the Impeller
Replace the impeller
Clean the Filter Bag
replace the drive Belt
Clean Filter Bag
Clean Filter Bag
Replace the Drive Belt
Replace the Sponge Wheel
replace axis sleeves
Wobble iCleaner-200D and
make sure air released
Replace the broken filter bag
Please turn
off the power
before you
perform any
maintenance
on the
iCleaner-200D
Note: The Power Box MUST BE DISCONNECTED from the power supply prior to conducting any maintenance on the iCleaner-200D. Contact your local distributor, or place of purchase for problems not covered in the Troubling Shooting Guide.
- 17 -
you must hold cleaner
in water and make sure
sponge wheel soak enough,
normal time is
about 5 -15 minutes
- 18 -
Indicator light
Solution
Failure
Green light
flashing
The iCleaner has stopped bue to lack of wanter
Return the robot to deeper water and restart
Yellow light
flashing
The pump motor has over heated
Contact the supplier for support
Blue light
flashing
The robot is upside down
Turn the iCleaner over, and restart using the remote control or power switch
Blue and Green lights flashing
The walking (drive wheel) motors are over loaded
1Check the walking motors, Drive tracks and tacking belts for debris or damage. 2Clear debris or replace parts and restart the iCleaner
Blue Green and Y ellow
lights flashing
The pump motor is overloaded
Turn the robot off, check the impeller for debris, or damage. Clear or replace impeller, then restart the iCleaner.
-19-
7 Safety Checklist
Please shut down the iCleaner-200D according to chapter 4.3 when you
have finished cleaning the pool.
Please inspect and clean the impeller & Guide Vane according to chapter
5.1, after use.
If you are not going to use the iCleaner-200D for an extended period of
time, make sure iCleaner-200D & Power Box is turned off, and store it in a
dry, shady & well ventilated area, with a temperature range between
0-40. If you want to reuse iCleaner-200D after it has been stored for an extended
period of time, please check the iCleaner-200D for visual damage (cracks
& rust) prior to use. Once you are sure iCleaner-200D is free from damage,
test run it, and if it performs as expected, then allow it to run automatically.
If the iCleaner-200D requires repair, please contact your local distributor, or
contact service@ichroboter.com.