THIS MANUAL IS PART OF THE PRODUCT. READ IT CAREFULLY IN ORDER
TO USE AND MAINTAIN THE EQUIPMENT CORRECTLY. IT IS IMPORTANT TO
KEEP IT FOR FUTURE TROUBLESHOOTING AND REFERENCE.
WARNING
The installation of this equipment should be done by the Technical Assistance Service department.
The inlet jack should always be placed on an accessible location.
ALWAYS disconnect the power supply from the machine BEFORE any cleaning or maintenance service.
Any change needed on the electrical installation for the appropriate connection of the machine, should be
exclusively performed by qualied and certied professional personnel only.
Any use by the ice maker not intended to produce ice, using drinking water, is considered inappropriate.
It is extremely dangerous to modify or intend to modify this machine, and shall make any type warranty
void.
This machine should not be used by children or handicapped without the proper supervision and
monitoring.
Children should be monitored to assure that they should not play near the equipment.
This machine is not intended to be used outdoors nor exposed to the rain.
Connect the equipment to the drinking water network.
The machine should be connected using the power cable supplied with the equipment. The connection is
not intended for xed cabling.
ENGLISH
IT IS MANDATORY TO GROUND THE EQUIPMENT.
To avoid possible discharges on individuals or damages to the equipment, the
machine should be grounded pursuant local and/or national regulations as the
case may be.
THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE OF DAMAGES
ARISING DUE TO THE LACK OF THE GROUND INSTALLATION.
In order to assure the proper operation and efciency of this equipment, it is of paramount importance to
follow the recommendations of the manufacturer, SPECIALLY THOSE RELATED TO CLEANING AND
MAINTENANCE OPERATIONS, which should be performed mostly by qualied personnel only.
CAUTION:
Do not try to perform repairs. The intervention of non-qualied personnel, besides of being dangerous,
could result in serious malfunctioning. In case of damages, contact your distributor. We recommend to
always use original replacement and spare parts.
Perform all discharge and recovery of materials or waste according the national regulations in force.
5
55
ENGLISH
RECEPTION OF THE MACHINE
Inspect the outside packing. In case of damages, MAKE THE CORRESPONDING CLAIM TO THE
CARRIER.
To conrm the existence of damages, UNPACK THE MACHINE IN THE PRESENCE OF THE CARRIER and
state any damage on the equipment on the reception document, or on a separate instrument. As from May
1, 1998, we complie with the European regulations on management of packing and packing waste, inserting
the “Green Dot Label” on all their packages.
Always state the machine number and model. This number is printed on four locations:
1. PACKING
On the outside, it contains a label with the manufacturing number (1).
2. EXTERIOR OF THE EQUIPMENT
On the back of the equipment, there appears a label
with the same characteristics as the previous one (1).
3. NAMEPLATE
On the back of the machine.
Check that in interior of the machine the
installation kit is complete and comprises:
- Ice scraper, ¾ gas pipe, lters and manual.
- 22 mm drain hose in models 45 and 85
and in water cooled machines
- In some models, shims are included.
- Warranty and serial number.
(1)
CAUTION: ALL PACKING ELEMENTS (plastic bags, carton boxes and wood pallets)
SHOULD BE KEPT OUTSIDE THE REACH OF CHILDREN, AS THEY ARE A SOURCE
OF POTENTIAL HAZARD.
INSTALLATION
THIS ICE MAKER IS NOT DESIGNED FOR OUTDOOR OPERATION.
An incorrect installation of the equipment may cause damages to individuals, animals
or other materials, being the manufacturer not responsible for such damages.
CAUTION:
The machines are designed to operate at room temperature between 5ºC (41ºF) and 43ºC (109.40ºF), with
inlet water temperature between 5ºC (41ºF) and 35ºC (95ºF).
The reduction motor is excessively forced if operated under the minimum temperatures. Above the
maximum temperature, the life of the compressor is shortened and the production is substantially less.
Do not place anything over the maker or facing the front louver.
66
In case the front louver is not enough, the exit is either total or partially obstructed or due to its placement
it will receive hot air from another device, we recommend, in case it is not possible to change the location
of the machine, TO INSTALL A WATER CONDENSER.
IT IS IMPORTANT THAT THE WATER PIPING DO NOT PASS BY OR NEAR SOURCES
OF HEAT SO AS NOT TO LOSE ICE PRODUCTION.
THREAD THE SUPPORT LEGS TO THE BASE OF THE MACHINE ON THE
HOUSING SET TO SUCH END AND REGULATE THE HEIGHT AS TO HAVE THE
EQUIPMENT PERFECTLY LEVELED.
>4''
>10 cm
Jack
Base jack
Bib
Water connection hose
ENGLISH
Ventilation louver
IN MODULAR MACHINES
Jack
>4''
>10 cm
Discharge hose
Base jack
Bib
Water connection hose
Condenser discharge outlet
Silo drainage
7
7
ENGLISH
1. WATER AND DRAINAGE
Water quality has a remarkable inuence on the appearance,
hardness and avor of the ice as well as, on the machines
condensated by water, on the life of the condenser.
2. CONNECTIONS TO THE WATER
NETWORK
Use a exible pipe (1.3 m – 4.27 feet length) with the two lter
joints supplied with the machine. We strongly discourage the
use of two-exit bibs and two switches as, due to an error
could close that back one, leaving the machine without water
supply. This could result on a damage call without actually
existing one.
Pressure should be established between 0.7 and 6 Bar (10 /
85 psi.)
If pressures overpass such values, install the necessary
corrective devices.
INSTALL A 10 µ PARTICLE FILTER INCLUDED IN THE
KI T.
3. CONNECTION TO DRAINAGE
Drainage should be located lower to the machine level, at 150 mm (5.91 inches) minimum.
It is convenient that the drainage pipe is of 30 mm (1.18 in) of interior diameter and with a
minimum gradient of 3 cm (1.18 in) per meter (see gure).
CORRECTINCORRECT
Descending
INCORRECT
8
Ascending
4. ELECTRICAL CONNECTION
IT IS MANDATORY TO GROUND THE EQUIPMENT.
To avoid possible discharges on individuals or damages to the equipment, the
machine should be grounded pursuant local and/or national regulations as the
case may be.
THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE OF DAMAGES
ARISING DUE TO THE LACK OF THE GROUND INSTALLATION.
The machine is supplied with a 1.5 m (4.92 feet) cable of length. In case the supply cable is damaged, it should
be replaced by a cable of special assembly to be furnished by the manufacturer or post-sale service. Such
replacement should be performed by qualied technical service only.
The machine should be places in such a way as to allow a minimum space between the back and the wall to
allow an easy access and without risks to the cable jack.
Safeguard the base of the jack.
It is convenient to install adequate switches and fuses.
The line up to the jack should have a minimum section of 2.5 mm2 (0.0038 in2)
Voltage and tension are indicated in the nameplate and on the technical specications
of this manual. Variation on voltage above the 10% stated on the nameplate could
result on damages or prevent the machine start-up.
5. INSTALLATION OF MODULAR EQUIPMENTS OVER DEPOSITS OR SILOS
ENGLISH
Modular makers should be installed over deposits
or silos, following the instructions contained in this
manual.
The resistance and stability of the
container-machine/s assembly should be veried,
as well as the fastening elements.
6. ASSEMBLY OF THE DISPERSION CONE
(MODULAR MODELS)
This device distributes the ice in the silos, and
avoids ice compression under the exit pipe.
Changing its position, the ice could be directed to
any direction.
9