Ice-O-Matic ICEU070A User Manual

SERVICE AND INSTALLATION MANUAL
ICE UNDERCOUNTER SERIES CUBERS
MODEL-ICEU070A
Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081374-01 Date 2/08
ICEU070A
INTRODUCTION
NOTE. To retain the safety and performance built into this ice machine, it is important that installation and maintenance be conducted in the manner outlined in this manual.
Table of Contents
Specifications ·········································· Page 2
General Information And Installation ······························ Page 3
Water Supply And Drain Connections ······························ Page 4
Final Check List ········································· Page 5
Operating Instructions ······································ Page 6
Operational Checks ······································· Page 7
Component Description ····································· Page 8
Operation - Electrical Sequence ································· Page 9
Freeze Cycle··········································· Page 10
Cleaning Switch ········································· Page 11
Service Diagnosis ········································ Page 12
Service Diagnosis ········································ Page 13
Maintenance And Cleaning Instructions ····························· Page 14
Cleaning Water System ····································· Page 15
Wiring Diagram ········································· Page 17
Warranty ········································ Page 18
Page 1
Specifications
ICEU070A
The ice machine must be installed indoors in a controlled environment.
Minimum Maximum
0
Air Temp 50
Water Temp 40
F. 950F.
0
F. 1000F.
Water Pressure 20 PSI 80 PSI
Voltage 103.5 126.5
Operating the ice machine outside of the above limitations, or outdoors, is potentially damaging to the machine, and it is misuse of the machine. This may void the warranty.
Ice-O-Matic ice machines are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of agencies like NSF and UL.
Ice-O-Matic assumes no liability or responsibility of any kind for products manufactured by Ice-O-Matic that have been altered in any way, including the use of any part and/or other components not specifically approved by Ice-O-Matic.
Ice-O-Matic reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice.
UNPACKING AND INSPECTION
1. Call your authorized Ice-O-Matic Distributor or Dealer for proper installation.
2. Remove the front panel of the unit and inspect for any concealed damage. Notify carrier of your claim for the concealed damage.
3. Check that refrigerant lines do not rub against or touch other lines or surfaces, and that the fan blade moves freely.
4. Check that the compressor fits snugly onto all its mounting pads.
5. Remove all internal support packing and masking tape.
Model Electrical (volts/Hz/phase) Fuse Size Amps Condenser Type Refrigerant Charge
ICEU070A 115/60/1 15 6 Forced Air 9.5 oz R-134a
Door Opening: 12 1/8" wide by 8 1/4" tall
3 1/16"
2 11/16"
1 9/16" Cord Set
3 7/16" Drain
28 7/8"
5/8"
1 13/16"
15 3/16"
11 5/8"
34 3/16"
4 11/16"
Legs adjust to 6" from base.
6"
Min for utility connections
25 5/8"
20 15/16"
16 1/8"
33/4"
Page 2
8 1/8"
3/4" GAS / BSPP
ICEU070A
General Information And Installation
This model is supplied from the factory completely pre-wired and requires only electrical power connections to the wire cord provided at rear of the unit.
Make sure that the ice machine is connected to its own circuit and individually fused (see data plate for maximum fuse size). This is a cord-connected unit designed for 115 volt AC power, with a maximum fuse size of 15 amps.
Low voltage can cause improper operation and may be responsible for serious damage to the overload switch and motor windings that is not covered by warranty.
NOTE. All external wiring should conform to national, state and local standards and regulations.
Check voltage on the line and the ice maker’s data plate before connecting the unit. Extension cords must not be used.
Location: If the unit is built into a cabinet with no side ventilation, the ice production will be reduced by 20% of rated capacity, restricted space of an inch or so on each side will cause a 10% reduction. Six inches of space to the left and right will allow the unit to operate satisfactorily.
To keep your Ice-O-Matic ice machine at peak performance levels, periodic maintenance checks must be carried out as indicated on the Maintenance and Cleaning section of this manual.
Warranty
The warranty statement for this product is on page 18 of this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed in this manual.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water temperature, conditions of the condenser air filter and age of the machine.
Page 3
Water Supply And Drain Connections
ICEU070A
General
When choosing the water supply for the ice cuber consideration should be given to:
a) Length of run
b) Water clarity and purity
c) Adequate water supply pressure
Low water pressure, below 20 psi may cause a malfunction.
Water containing excessive minerals will tend to produce cloudy colored ice cubes, plus scale build-up on parts of the water system.
Water Supply
The recommended water supply line is a 3/8" o.d. copper tube, the water pressure must have a minimum incoming pressure of 20 psig.
Connect the tubing to the 3/4" GAS / BSPP thread water inlet fitting at the back of the ice maker. An adapter is available, the part numbers are: Water Inlet Adapter-1011411-64 and Water Inlet Adapter O-Ring-1011411-65.
Water Drain
The recommended drain tube is a plastic or flexible tube with 18 mm (3/4") I.D. which runs to an open trapped and vented drain.
Note: Although soft, easily kinked vinyl tubing is not recommended for a drain, a short length of ¾” ID vinyl tubing is required to connect a rigid drain tube to the 20 mm (25/32”) fitting on the back of the machine.
NOTE. The water supply and the water drain must be installed to conform to the local code. In some case a licensed plumber and/or a plumbing permit is required.
Water Inlet
Connection
Water Drain
Connection
Back View of Utility Connections
Page 4
ICEU070A
Final Check List
1. Is the unit in a room where ambient temperatures are above a minimum of 10oC (50 even in winter months?
2. Is there at least a 15 cm (6") clearance around the unit for proper air circulation?
3. Is the unit level? (IMPORTANT)
4. Have all the electrical and plumbing connections been made, and is the water supply shut-off valve open?
5. Has the voltage been tested and checked against the data plate rating?
6. Has the water supply pressure been checked to ensure a water pressure of at least 20 psi.
7. Check all refrigerant lines and conduit lines to guard against vibrations and possible failure.
o
F)
8. Have the bolts holding the compressor down been checked to ensure that the compressor is snugly fitted onto the mounting pads?
9. Have the bin liner and cabinet been wiped clean?
10. Has the owner/user been given the User Manual and been instructed on the importance of periodic maintenance checks?
11. Has the Manufacturer’s registration card been filled in properly? Check for correct model and serial number against the serial plate and mail the registration card to the factory.
12. Has the owner been given the name and the phone number of the authorized Ice-O-matic Service Agency serving him?
Connect Power, Water and Drain. Level the cabinet.