SERVICE AND INSTALLATION MANUAL
ICE UNDERCOUNTER SERIES CUBERS
MODEL-ICEU060
Mile High Equipment
11100 East 45th Av
Denver, Colorado 80239
Part Number 9081291-01Print Date 11/01
Introduction ICEU060
To the owner or user: This product manual is a source of information about the installation,
start up, cleaning, maintenance, and repair of the product.
Table of Contents
IntroductionPage 1
Specifications/LimitationsPage 2
InstallationPage 3-5
Initial Start UpPage 6
How It Works-Component DescriptionPage 7
Component LocationPage 8
How It Works-Water SystemPage 9
How It Works-RefrigerationPage 10-11
Operation And AdjustmentPage 12
Sanitizing And CleaningPage 13
Service DiagnosisPage 14
Component ReplacementPage 15-16
Wiring DiagramPage 17-18
Warranty InformationPage 2
Note the warning symbol where it appears in this manual.
It is an alert for important safety information on a hazard
that might cause serious injury.
Keep this manual for future reference.
Ice-O-Matic
11100 E. 45th Ave.
Denver, Co. 80239
800-423-3367
The ICEU060 Service Parts Manual is available separately, Part Number 9081291-02
Page 1
Specifications ICEU060
Specifications:
24 HourBin Storage BasicMaximum Ref Type.
Model NumberCapacity CapacityElectricalFuse SizeOunces
ICEU060 55 lbs. 28 lbs.115/60/1 15R134a, 9.5 oz
Operating Requirements:MinimumMaximum
Air Temperature50° F100° F
Water Temperature40° F100° F
Water Pressure20 PSIG100 PSIG
Voltage103.5 V126.5 V
Ice-O-Matic ice machines are not designed for outdoor installations.
Machine requires voltage indicated on rating nameplate. Failures caused by improper voltage are
not considered factory defects. Extended periods of operation at temperatures exceeding
limitations constitutes misuse under the terms of the Ice-O-Matic Manufacture’s Limited Warranty,
resulting in a loss of warranty coverage. Specifications and design are subject to change without
notice.
The ICEU060 ice machine has a 3 year Parts Warranty and a 3 year Labor Warranty.
The Compressor and Evaporator have a 5 year Parts Warranty
Ice-O-Matic recommends the installation of water filters.
Page 2
Installation ICEU060
Location:
Prior consideration for the location of the ice machine shall include:
Installation location to be indoors with a minimum room temperature of 50°F and with a maximum
room temperature of 100°F.
The incoming water temperature to the machine should be between 40°F and 100°F.
Service Access. Allow enough space at the rear of the cabinet for the utility connections. Allow
enough space for the machine to be pulled out from its installed location. Do not build a floor in
front of the machine that would prevent its removal.
Air Circulation. The front panel must remain unobstructed. Do not block the front panel area with
any type of door or curtain. The air intake is on the right hand side of the front panel, and the
exhaust is on the left side of the front panel and the cabinet left hand side panel. If the unit in
installed in a “built-in” cabinet, position the machine so that the left side of the unit is tight against
the cabinet.
Page 3
Installation ICEU060
Water Supply and Drain Connection:
1. The recommend water supply line is ¼ inch O.D. copper tubing. The minimum incoming water
pressure should be 20 psig.
2. Connect the water supply tubing to the water inlet fitting (3/4 hose thread) at the rear of the
icemaker. An optional adapter (1/4 compression x ¾ hose thread) is available under part
number 1011337-43, or from a local hardware store
3. Install a water shutoff valve on the incoming water line near the icemaker so that the water can
be shut off for service.
4. Connect a gravity drain line to the drain connection at the icemaker. A minimum slope of ¼
inch fall per foot of horizontal run is recommended. Install the drains per local code. A vent is
recommended on the highest point of the drain tube, and the drain tubing must be rigid pipe.
DO NOT use flexible tubing.
Electrical
1. Locate the nameplate on the lower rear panel and check that the location source voltage and
capacity are correct for this unit. The unit is supplied with a grounded plug connection.
2.Under no circumstances must the ground post be altered or removed.
3. Be certain that the icemaker is connected to its own electrical circuit and is individually fused.
4. The maximum allowable voltage variation should not exceed ten percent of the name plate
rating.
5. All external wiring should conform to the National, State, and local electrical code requirements.
Usually an electrical permit and the services of a licensed electrician will be required to install
the receptacle.
Page 4
Installation ICEU060
Final Check:
1. Is the cabinet level?
2. Have all the electrical and piping connection been made?
3. Has the voltage been tested and checked against the nameplate rating?
4. Is the unit plugged into a separate electrical circuit?
5. Is the water supply line shut off valve installed and is the water turned on?
6. Have the bin interior and cabinet exterior been wiped clean?
7. Are all internal components in place including spray platform and curtain?
8. Have the internal refrigerant lines been checked for rubbing and chaffing?
9. Has the machine been installed indoors, in a controlled environment with adequate air
circulation around the machine, and where it can be serviced?