Ice-O-Matic ICE0250 User Manual

SERVICE AND INSTALLATION MANUAL
THE ICE SERIES CUBERS
ICE0250 through ICE2100 SERIES*
*Includes Undercounter and 22 Inch Series
ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081270-01 Date 1/08
Table of Contents
Table of Contents Page A1 General Information
How To Use This Manual Page A2 Model And Serial Number Format Page A3 Electrical And Mechanical Specifications Page A5-A8 Installation Guidelines Page A9 Electrical And Plumbing Requirements Page A10-A17 Remote Condenser Installation Page A18-A19 How The Machine Works Page A20 Undercounter Model Bin Removal Page A21-A22 Warranty Information Page A23-A24
Scheduled Maintenance
Maintenance Procedure Page B1 Cleaning and Sanitizing Instructions Page B1-B2 Winterizing Procedure Page B3 Cabinet Care Page B4
Troubleshooting Trees
How to Use The Troubleshooting Trees Page C1 Troubleshooting Trees Table Of Contents Page C2 Troubleshooting Trees Page C3-C18
Water System
Water Distribution And Components Page D1-D5
Refrigeration System
Refrigeration Cycle And Components Page E1 Harvest Cycle Page E5 Remote System Page E5-E6 Pump Down System Page E7 Refrigerant Specifications Page E8-E20
Electrical System
Control Circuit Page F1 Compressor And Start Components Page F1-F2 Untimed Freeze Cycle Page F3 Timed Freeze Cycle Page F4 Harvest Cycle Page F5-F9 Pump Down System Page F9 Wiring Diagrams Page G1
Table of Contents
Table of Contents Page A1 General Information
How To Use This Manual Page A2 Model And Serial Number Format Page A3 Electrical And Mechanical Specifications Page A5-A8 Installation Guidelines Page A9 Electrical And Plumbing Requirements Page A10-A17 Remote Condenser Installation Page A18-A19 How The Machine Works Page A20 Undercounter Model Bin Removal Page A21-A22 Warranty Information Page A23-A24
Scheduled Maintenance
Maintenance Procedure Page B1 Cleaning and Sanitizing Instructions Page B1-B2 Winterizing Procedure Page B3 Cabinet Care Page B4
Troubleshooting Trees
How to Use The Troubleshooting Trees Page C1 Troubleshooting Trees Table Of Contents Page C2 Troubleshooting Trees Page C3-C18
Water System
Water Distribution And Components Page D1-D5
Refrigeration System
Refrigeration Cycle And Components Page E1 Harvest Cycle Page E5 Remote System Page E5-E6 Pump Down System Page E7 Refrigerant Specifications Page E8-E20
Electrical System
Control Circuit Page F1 Compressor And Start Components Page F1-F2 Untimed Freeze Cycle Page F3 Timed Freeze Cycle Page F4 Harvest Cycle Page F5-F9 Pump Down System Page F9 Electrical Sequence ICE1400-2100 Version 3 Page F10 Wiring Diagrams Page G1
Page A1

How To Use This Manual

Ice-O-Matic provides this manual as an aid to the service technician in installation, operation, and maintenance of the ICE Series (electro-mechanical) cube ice machines. If used properly this manual can also assist the service technician to troubleshoot and diagnose most of the problems that may occur with the machine.
The first two sections of this manual provide general information and maintenance information. The remainder of the manual beginning with Section C provides troubleshooting and service information. Section C contains flow charts called troubleshooting trees. Page C-1 provides instructions on using the troubleshooting trees. Each troubleshooting tree is named to describe a particular problem with the operation of the machine.
When following the troubleshooting trees, the service technician will be led through questions and checks and end up with a probable solution. When using the troubleshooting trees, it is important that the service technician understand the operation and adjustments of the components being checked and the component suspected of malfunctioning. A detailed description of the operation and adjustments of the components as well as other service information is available in the pages that follow Section C.
Sections D, E, and F focus on a particular system in the ice machine: water distribution system, refrigeration system, and it is important that these sections be used together with the Troubleshooting Trees in Section C.
Most aspects of the ICE Series machines are covered in this manual, however, should you encounter any conditions not addressed herein, please contact the Ice-O-Matic Technical Service Department for assistance. You may also fax, e-mail or write the Ice-O-Matic Technical Service Department:
Ice-O-Matic 11100 E. 45th Ave. Denver, Co. 80239 Attn: Technical Service Department E-Mail: Tech.service@iceomatic.com
Telephone Numbers Any Service communication must include: 800-423-3367 All Department Model Number 888-349-4423 Technical Assistance Only Serial number 303-371-3737 A detailed explanation of the problem
Note the warning symbol where it appears in this manual. It is an alert for important safety information on a hazard that might cause serious injury. Keep this manual for future reference.
The ICE Series Service Parts Manuals are available separately.
Ice-O-Matic products are not designed for outdoor installation.
Page A2
Model and Serial Number Format Model Numbers
040 0 H A
ICE
Cube Size: H=Half (3/8 X 7/8 X7/8) F=Full (7/8 X 7/8 X7/8) Voltage: 0=115V 5=240/50/1 6=208-230/60/1 7=208-230/60/3 Approximate 24 hour ice production: (x 10 @ 70°F/21°C Air and 50°F/10°C Water) Series: Slab ice cuber, Stainless Steel Cabinet
Serial Number Date Code
The first letter in the serial number indicates the month and decade of manufacture. The first digit in the serial number indicates the year of manufacture.
Example: A0XX-XXXXX-Z is manufactured January 2000 A1XX-XXXXX-Z is manufactured January 2001
1990-1999 MONTH 2000-2004 M JANUARY A
N FEBRUARY B P MARCH C Q APRIL D R MAY E S JUNE F T JULY G U AUGUST H V SEPTEMBER I W OCTOBER J Y NOVEMBER K Z DECEMBER L
Note: The letter O and letter X are not used.
Reference new serial number format on next page.
Condenser Type: A=Air W=Water R=Remote T=Top Discharge Air Cooled
Page A3

Model and Serial Number Format

Since all Enodis companies will eventually be utilizing same operating system, a company wide format for serial numbers has been designed.
This format is 14 characters long and begins with a date code followed by the Ice-O-Matic identifier, and then a sequential number. This is an entirely numerical serial number.
The new serial number will look like the example.
1280 010123
0407
010123 is the serial identifier. 1280 is the identifier. (Ice-O-Matic)
0407 is the date code, in YYMM format. (2004 July)
The date code will change monthly and yearly to reflect the date of manufacture.
Large data plate will be placed on the back of the unit.
valves.
Small data plate will be placed by the service
Page A4
ICE Series General Information
Voltage @ 90/70 Including Fuse Circuit Comp. **Refrigerant
Model Hz/Phase Lbs. Kg. BTUH Ground Size Amps RLA Type Oz. Grams
ICEU150*A1 115/60/1 117 53 3148 3 15 9.6 6.8 R404A 13 369 ICEU150*W1 115/60/1 166 75 3392 3 15 7.9 5.9 R404A 10 284 ICEU150*A2 115/60/1 117 53 3148 3 15 9.6 6.8 R404A 13 369 ICEU150*W2 115/60/1 166 75 3392 3 15 7.9 5.9 R404A 10 284 ICEU150*A3 115/60/1 112 51 3572 3 15 9.7 6.9 R404A 12 340 ICEU150*W3 115/60/1 155 70 3732 3 15 7.9 5.9 R404A 9 284 ICEU200*A1 115/60/1 157 71 4435 3 15 11.6 8.2 R404A 13 369 ICEU200*W1 115/60/1 183 83 4199 3 15 8.9 6.7 R404A 9 256 ICEU200*A2 115/60/1 157 71 4435 3 15 11.6 8.2 R404A 13 369 ICEU200*W2 115/60/1 183 83 4199 3 15 8.9 6.7 R404A 9 256 ICEU220A 115/60/1 175 80 4609 3 15 11.9 8.5 R404A 12 340 ICEU220W 115/60/1 220 100 4642 3 15 8.9 6.7 R404A 9 256 ICEU206*A1 230/60/1 162 74 4115 3 15 4.8 3.2 R-134a 14 397 ICEU206*W1 230/60/1 190 86 4009 3 15 4.0 2.9 R-134a 11 312 ICEU226A 230/60/1 168 76 4321 3 15 6.0 4.2 R404A 12 340 ICEU226W 230/60/1 192 87 4263 3 15 4.4 3.2 R404A 9 256 ICEU300A 115/60/1 228 104 5928 3 15 13.1 8.8 R404A 16 454 ICEU300W 115/60/1 296 135 6097 3 15 11.1 8.5 R404A 13 369 ICE0250*A3 115/60/1 244 111 6221 3 15 13.3 8.6 R404A 16 454 ICE0250*A-T3 115/60/1 244 111 6221 3 15 13.3 8.6 R404A 16 454 ICE0250*W3 115/60/1 284 129 6030 3 15 10.8 8.2 R404A 13 369 ICE0250*A4 115/60/1 253 115 6248 3 15 13.3 8.6 R404A 25 709 ICE0250*A-T4 115/60/1 253 115 6248 3 15 13.3 8.6 R404A 25 709 ICE0250*W4 115/60/1 275 125 5855 3 15 10.8 8.2 R404A 13 369 ICE0320*A1 115/60/1 214 97 5910 3 15 13.8 9.0 R404A 18 510 ICE0320*W1 115/60/1 312 142 6195 3 15 10.9 8.3 R404A 15 425 ICE0320*A2 115/60/1 214 97 5910 3 15 13.8 9.0 R404A 18 510 ICE0320*W2 115/60/1 312 142 6195 3 15 13.1 10.1 R404A 11 312 ICE0320*A3 115/60/1 214 97 5910 3 15 13.8 9.0 R404A 18 510 ICE0320*W3 115/60/1 312 142 6195 3 15 13.1 10.1 R404A 11 312 ICE0400*A1 115/60/1 366 166 8064 3 15 14.4 9.5 R404A 32 907 ICE0400*A-T1 115/60/1 368 167 8101 3 15 14.1 9.3 R404A 32 907 ICE0400*W1 115/60/1 449 204 8388 3 15 13.4 10.3 R404A 14 397 ICE0400*A2 115/60/1 366 166 8064 3 15 14.4 9.5 R404A 29 822 ICE0400*A-T2 115/60/1 368 167 8101 3 15 14.1 9.3 R404A 29 822 ICE0400*W2 115/60/1 449 204 8388 3 15 13.4 10.3 R404A 14 397 ICE0400*A3 115/60/1 368 167 7835 3 20 17.1 11.7 R404A 30 851 ICE0400*A-T3 115/60/1 357 162 7757 3 20 17.1 11.7 R404A 30 851 ICE0400*W3 115/60/1 407 185 7563 3 15 12.9 9.9 R404A 14 397 ICE0406*A1 208-230/60/1 323 147 7712 3 15 8.8 5.9 R404A 32 907 ICE0406*W1 208-230/60/1 381 173 7664 3 15 7.5 5.7 R404A 16 454 ICE0406*A2 208-230/60/1 323 147 7712 3 15 8.8 5.9 R404A 32 907 ICE0406*W2 208-230/60/1 381 173 7664 3 15 7.5 5.7 R404A 16 454 ICE0406*A3 208-230/60/1 385 175 7832 3 15 8.0 5.3 R404A 30 850 ICE0406*W3 208-230/60/1 439 200 7770 3 15 6.4 4.8 R404A 14 397
24 Hour
Capacity
Wires Max Min.
Page A5
Voltage @ 90/70 Including Fuse Circuit Comp. **Refrigerant
Model Hz/Phase Lbs. Kg. BTUH Ground Size Amps RLA Type Oz. Grams
ICE0500*A1 115/60/1 461 210 10843 3 20 24.8* 18.5 R404A 37 1049 ICE0500*A-T1 115/60/1 455 207 10736 3 20 24.8* 18.5 R404A 37 1049 ICE0500*W1 115/60/1 499 227 10242 3 20 13.6 10.5 R404A 15 425 ICE0500*R1 115/60/1 407 199 10881 3 20 18.7 12.3 R404A 160 4536 ICE0500*A2 115/60/1 461 210 10843 3 20 19.9 13.9 R404A 22 624 ICE0500*A-T2 115/60/1 455 207 10736 3 20 19.9 13.9 R404A 22 624 ICE0500*W2 115/60/1 499 227 10242 3 20 13.6 10.5 R404A 15 425 ICE0500*R2 115/60/1 407 199 10881 3 20 18.7 12.3 R404A 160 4536 ICE0500*A3 115/60/1 458 208 9990 3 20 19.1 13.3 R404A 25 710 ICE0500*A-T3 115/60/1 470 214 9982 3 20 19.1 13.3 R404A 25 710 ICE0500*W3 115/60/1 513 233 9777 3 20 14.3 11.0 R404A 15 425 ICE0500*R3 115/60/1 446 203 11357 3 20 18.7 12.3 R404A 132 3742 ICE0500*R4 115/60/1 455 207 10278 3 20 14.9 9.3 R404A 132 3742 ICE0520*A1 115/60/1 353 160 8441 3 20 18.3 12.3 R404A 32 907 ICE0520*W1 115/60/1 442 201 8356 3 15 13.5 10.4 R404A 14 397 ICE0520*A2 115/60/1 353 160 8441 3 20 15.4 10.6 R404A 20 567 ICE0520*W2 115/60/1 442 201 8356 3 15 13.5 10.4 R404A 14 397 ICE0520*A3 115/60/1 370 168 7753 3 20 16.0 11.1 R404A 21 595 ICE0520*W3 115/60/1 442 201 7852 3 15 13.1 9.0 R404A 12 340 ICE0606*A1 208-230/60/1 525 239 11538 3 15 12.4 8.8 R404A 36 1021 ICE0606*A-T1 208-230/60/1 510 232 11293 3 15 13.3 9.5 R404A 36 1021 ICE0606*W1 208-230/60/1 590 268 11473 3 15 9.5 7.3 R404A 18 510 ICE0606*R1 208-230/60/1 544 247 12269 3 15 13.0 8.7 R404A 160 4536 ICE0606*A2 208-230/60/1 525 239 11538 3 15 12.0 8.5 R404A 24 680 ICE0606*A-T2 208-230/60/1 510 232 11293 3 15 11.7 8.2 R404A 24 680 ICE0606*W2 208-230/60/1 590 268 11473 3 15 9.5 7.3 R404A 18 510 ICE0606*R2 208-230/60/1 544 247 12269 3 15 13.0 8.7 R404A 160 4536 ICE0606*R3 208-230/60/1 543 247 12132 3 15 13.0 8.7 R404A 132 3742 ICE0606*A3 208-230/60/1 506 230 10566 3 15 11.5 7.9 R404A 24 680 ICE0606*A-T3 208-230/60/1 506 230 10566 3 15 10.4 7.0 R404A 24 680 ICE0606*W3 208-230/60/1 576 262 10767 3 15 8.7 6.6 R404A 17 482 ICE0606*R4 208-230/60/1 502 228 10850 3 15 12.9 8.6 R404A 132 3742 ICE0806*A1 208-230/60/1 698 317 15003 3 20 13.0 9.2 R404A 41 1163 ICE0806*W1 208-230/60/1 840 382 14458 3 20 9.8 7.4 R404A 29 823 ICE0806*R1 208-230/60/1 762 346 15168 3 20 12.3 8.1 R404A 240 6804 ICE0806*A2 208-230/60/1 698 317 15003 3 20 13.0 9.2 R404A 27 765 ICE0806*W2 208-230/60/1 840 382 14458 3 20 9.8 7.4 R404A 24 680 ICE0806*R2 208-230/60/1 762 346 15168 3 20 12.3 8.1 R404A 240 6804 ICE0806*R3 208-230/60/1 826 375 16371 3 20 12.3 8.1 R404A 176 4990 ICE1006*A1 208-230/60/1 811 369 16239 3 20 13.8 9.0 R404A 50 1418 ICE1006*W1 208-230/60/1 941 428 15986 3 20 9.0 6.8 R404A 32 908 ICE1006*R1 208-230/60/1 905 411 18149 3 20 13.8 9.3 R404A 240 6804 ICE1006*A2 208-230/60/1 811 369 16239 3 20 13.8 9.0 R404A 34 964 ICE1006*W2 208-230/60/1 941 428 15986 3 20 9.0 6.8 R404A 24 680 ICE1006*R2 208-230/60/1 905 411 18149 3 20 13.8 9.3 R404A 240 6804 ICE1006*R3 208-230/60/1 921 419 18377 3 20 13.8 9.3 R404A 176 4990 ICE1007*A1 208-230/60/3 767 349 15614 4 15 11.8 7.4 R404A 50 1418 ICE1007*W1 208-230/60/3 906 412 16487 4 15 7.1 5.3 R404A 32 908 ICE1007*R1 208-230/60/3 844 384 17653 4 15 10.8 6.9 R404A 240 6804 ICE1007*A2 208-230/60/3 767 349 15614 4 15 11.8 7.4 R404A 34 964 ICE1007*W2 208-230/60/3 906 412 16487 4 15 7.1 5.3 R404A 24 680 ICE1007*R2 208-230/60/3 844 384 17653 4 15 10.8 6.9 R404A 240 6804 ICE1007*R3 208-230/60/3 844 384 17653 4 15 10.8 6.9 R404A 176 4990
24 Hour
Capacity
Wires Max Min.
Page A6
ICE Series General Information
Voltage @ 90/70 Including Fuse Circuit Comp. **Refrigerant
Model Hz/Phase Lbs. Kg. BTUH Ground Size Amps RLA Type Oz. Grams
ICE1406*A1 208-230/60/1 1122 510 22590 3 30 20.2 13.8 R404A 108 3062 ICE1406*W1 208-230/60/1 1187 540 22529 3 20 15.6 11.7 R404A 28 794 ICE1406*R1 208-230/60/1 1134 515 23085 3 25 23.3 16.5 R404A 240 6804 ICE1406*A2 208-230/60/1 1122 510 22590 3 30 20.2 13.8 R404A 104 2948 ICE1406*W2 208-230/60/1 1187 540 22529 3 20 15.6 11.7 R404A 25 709 ICE1406*R2 208-230/60/1 1134 515 23085 3 25 23.3 16.5 R404A 240 6804 ICE1406*A3 208-230/60/1 1109 504 21957 3 30 26.1 13.8 R404A 60 1701 ICE1406*W3 208-230/60/1 1239 563 21994 3 20 17.8 11.7 R404A 30 850 ICE1406*R3 208-230/60/1 1150 523 22126 3 30 22.2 16.5 R404A 240 6804 ICE1407*A1 208-230/60/3 989 450 19765 4 25 15.1 9.7 R404A 108 3062 ICE1407*W1 208-230/60/3 1093 497 19809 4 20 9.8 7.1 R404A 28 794 ICE1407*R1 208-230/60/3 956 435 20173 4 25 14.0 9.1 R404A 240 6804 ICE1407*A2 208-230/60/3 989 450 19765 4 25 15.1 9.7 R404A 104 2948 ICE1407*W2 208-230/60/3 1093 497 19809 4 20 9.8 7.1 R404A 25 709 ICE1407*R2 208-230/60/3 956 435 20173 4 25 14.0 9.1 R404A 240 6804 ICE1407*A3 208-230/60/3 1131 514 21761 4 20 16.0 9.7 R404A 60 1701 ICE1407*W3 208-230/60/3 1270 577 22308 4 20 10.7 7.1 R404A 30 850 ICE1407*R3 208-230/60/3 1195 543 22547 4 20 14.7 9.1 R404A 240 6804 ICE1506*R 208-230/60/1 1202 559 24337 3 30 27.4 19.8 R404A 240 6804 ICE1506*R 208-230/60/1 1207 549 22999 3 30 24.5 R404A 240 6804 ICE1606*R1 208-230/60/1 1240 564 24343 3 30 25.8 18.6 R404A 240 6804 ICE1806*W1 208-230/60/1 1461 664 25663 3 30 17.0 12.9 R404A 42 1191 ICE1806*R1 208-230/60/1 1468 667 27152 3 30 22.3 15.7 R404A 400 11340 ICE1806*W2 208-230/60/1 1461 664 25663 3 30 17.0 12.9 R404A 35 992 ICE1806*R2 208-230/60/1 1468 667 27152 3 30 22.3 15.7 R404A 400 11340 ICE1806*W3 208-230/60/1 1628 740 27687 3 30 22.0 16.9 R404A 37 1049 ICE1806*R3 208-230/60/1 1461 664 28110 3 30 27.7 20.1 R404A 272 7711 ICE1807*W1 208-230/60/3 1556 707 27146 4 15 10.7 7.8 R404A 42 1191 ICE1807*R1 208-230/60/3 1491 678 27966 4 15 15.5 10.3 R404A 400 11340 ICE1807*W2 208-230/60/3 1556 707 27146 4 15 10.7 7.8 R404A 35 992 ICE1807*R2 208-230/60/3 1491 678 27966 4 15 15.5 10.3 R404A 400 11340 ICE1807*W3 208-230/60/3 1603 729 27560 4 15 12.3 9.1 R404A 37 1049 ICE1807*R3 208-230/60/3 1444 656 27514 4 20 17.1 11.6 R404A 272 7711 ICE2106*W1 208-230/60/1 1855 843 33333 3 30 28.5 22.1 R404A 50 1418 ICE2106*R1 208-230/60/1 1723 783 35369 3 50 43.1 31.0 R404A 400 11340 ICE2106*W2 208-230/60/1 1855 843 33333 3 30 25.3 19.5 R404A 37 1049 ICE2106*R2 208-230/60/1 1723 783 35369 3 50 33.7 23.5 R404A 400 11340 ICE2106*W3 208-230/60/1 1692 769 29406 3 30 22.3 17.1 R404A 44 1247 ICE2106*R3 208-230/60/1 1561 710 30325 3 30 26.9 18.1 R404A 272 7711 ICE2107*W1 208-230/60/3 1853 842 32928 4 20 13.9 10.4 R404A 50 1418 ICE2107*R1 208-230/60/3 1737 790 34714 4 25 22.3 14.4 R404A 400 11340 ICE2107*W2 208-230/60/3 1853 842 32928 4 20 16.6 12.6 R404A 37 1049 ICE2107*R2 208-230/60/3 1737 790 34714 4 25 23.2 15.1 R404A 400 11340
ICE2107*W3 208-230/60/3 1650 750 28676 4 30 13.5 10.1 R404A 44 1247 ICE2107*R3 208-230/60/3 1525 693 29342 4 25 21.2 13.5 R404A 272 7711
50HZ.
Voltage @ 90°/70° Including Fuse Circuit Comp. **Refrigerant
Model Hz/Phase Lbs. Kg. BTUH Ground Size Amps RLA Type Oz. Grams
ICEU205*A1 230/50/1 145 66 3842 3 15 6.0 4.1 R-134a 14 397 ICEU205*W1 230/50/1 175 80 3768 3 15 5.6 4.2 R-134a 11 312 ICEU205*A2 230/50/1 145 66 3842 3 15 6.0 4.1 R-134a 14 397 ICEU205*W2 230/50/1 175 80 3768 3 15 5.6 4.2 R-134a 11 312 ICEU225*A 230/50/1 143 65 3774 3 15 4.9 3.3 R404A 12 340 ICEU225*W 230/50/1 174 79 3780 3 15 4.1 3.0 R404A 9 256 ICEU305A 230/50/1 223 101 5392 3 15 6.4 4.2 R404A 14 397 ICEU305W 230/50/1 267 121 5080 3 15 4.7 3.5 R404A 13 369
24 Hour
Capacity
24 Hour
Capacity
Wires Max Min.
Wires Max Min.
Page A7
ICE Series General Information
50 hz.
Voltage @ 90°/70° Including Fuse Circuit Comp. **Refrigerant
Model Hz/Phase Lbs. Kg. BTUH Ground Size Amps RLA Type Oz. Grams
ICE0305*A2 230/50/1 266 121 7079 3 15 12.4 8.2 R404A 26 737 ICE0305*W2 230/50/1 291 132 6590 3 15 8.5 8.2 R404A 14 397 ICE0305*A4 230/50/1 279 127 6689 3 16 8.4 5.8 R404A 23 650 ICE0305*W4 230/50/1 296 135 6265 3 16 6.6 5.0 R404A 12 340 ICE0325*A1 230/50/1 214 97 4990 3 15 6.2 4.4 R404A 22 624 ICE0325*A2 230/50/1 214 97 4990 3 15 6.2 4.4 R404A 22 624 ICE0325*A3 230/50/1 214 97 4990 3 16 6.6 4.4 R404A 22 624 ICE0405*A1 230/50/1 370 168 9371 3 15 13.3 8.2 R404A 32 907 ICE0405*W1 230/50/1 470 214 8562 3 15 10.1 8.2 R404A 16 454 ICE0405*A2 230/50/1 370 168 9371 3 15 13.3 8.2 R404A 23 650 ICE0405*W2 230/50/1 470 214 8562 3 15 10.1 8.2 R404A 16 454 ICE0405*A3 230/50/1 366 166 7735 3 16 8.2 5.4 R404A 23 650 ICE0405*W3 230/50/1 440 200 8213 3 16 6.2 4.4 R404A 13 369 ICE0525*A1 230/50/1 478 217 8061 3 15 7.8 5.1 R404A 21 595 ICE0525*A2 230/50/1 478 217 8061 3 15 7.8 5.1 R404A 21 595 ICE0525*A3 230/50/1 404 184 8617 3 16 9.2 5.5 R404A 21 595 ICE0605*A1 230/50/1 466 212 10284 3 15 8.8 8.4 R404A 32 907 ICE0605*W1 230/50/1 470 214 9909 3 15 6.8 8.4 R404A 14 397 ICE0605*R1 230/50/1 425 193 10708 3 15 9.9 8.4 R404A 160 4536 ICE0605*A2 230/50/1 466 212 10284 3 15 8.8 8.4 R404A 22 624 ICE0605*W2 230/50/1 470 214 9909 3 15 6.8 8.4 R404A 14 397 ICE0605*R2 230/50/1 425 193 10708 3 15 9.9 8.4 R404A 160 4536 ICE0605*R3 230/50/1 425 193 10708 3 15 9.9 8.4 R404A 132 3742 ICE0605*A3 230/50/1 459 209 9523 3 16 8.7 6.7 R404A 22 624 ICE0605*W3 230/50/1 523 238 9684 3 16 6.8 5.4 R404A 14 397 ICE0605*R4 230/50/1 474 215 10138 3 16 9.9 6.3 R404A 132 3742 ICE0805*A1 230/50/1 615 280 13321 3 15 12.0 10.9 R404A 41 1162 ICE0805*W1 230/50/1 855 389 14382 3 15 9.2 10.9 R404A 29 822 ICE0805*R1 230/50/1 738 335 14474 3 15 13.0 10.9 R404A 240 6804 ICE0805*A2 230/50/1 615 280 13321 3 15 12.0 10.9 R404A 27 765 ICE0805*W2 230/50/1 855 389 14382 3 15 9.2 10.9 R404A 24 680 ICE0805*R2 230/50/1 738 335 14474 3 15 13.0 10.9 R404A 240 6804 ICE0805*R3 230/50/1 738 335 14474 3 15 13.0 10.9 R404A 176 4990 ICE1005*A1 230/50/1 742 337 15699 3 15 13.3 12.5 R404A 50 1417 ICE1005*W1 230/50/1 917 417 16005 3 15 9.5 12.5 R404A 32 907 ICE1005*R1 230/50/1 801 364 16127 3 15 15.1 12.5 R404A 240 6804 ICE1005*A2 230/50/1 742 337 15699 3 15 13.3 12.5 R404A 33 936 ICE1005*W2 230/50/1 917 417 16005 3 15 9.5 12.5 R404A 24 680 ICE1005*R2 230/50/1 801 364 16127 3 15 15.1 12.5 R404A 240 6804 ICE1005*R3 230/50/1 801 364 16127 3 15 15.1 12.5 R404A 176 4990 ICE1405*A1 230/50/1 901 410 19348 3 25 20.8 15.4 R404A 108 3062 ICE1405*W1 230/50/1 1107 503 20269 3 20 15.4 15.4 R404A 28 794 ICE1405*R1 230/50/1 1002 455 21330 3 25 18.1 15.4 R404A 240 6804 ICE1405*A2 230/50/1 901 410 19348 3 25 20.8 15.4 R404A 104 2950 ICE1405*W2 230/50/1 1107 503 20269 3 20 15.4 15.4 R404A 25 710 ICE1405*R2 230/50/1 1002 455 21330 3 25 18.1 15.4 R404A 240 6804 ICE1405*A3 230/50/1 1070 486 21185 3 30 21.7 14.5 R404A 60 1701 ICE1405*W3 230/50/1 1185 539 21035 3 20 15.1 11.5 R404A 25 710 ICE1405*R3 230/50/1 1139 518 22239 3 30 21.9 15.6 R404A 240 6804 ICE2005*W1 230/50/1 1702 774 29643 3 30 20.3 21.5 R404A 50 1417 ICE2005*R1 230/50/1 1490 677 29750 3 50 34.3 21.5 R404A 400 11340
24 Hour
Capacity
Wires Max Min.
Page A8
ICE Series General Information Installation Guidelines
Note: Installation should be performed by an Ice-O-Matic trained Service Technician. For proper operation of the Ice-O-Matic ice machine, the following installation guidelines must be followed. Failure to do so may result in loss of production capacity, premature part failures, and may void all warranties.
Ambient Operating Temperatures
Minimum Operating Temperature: 50°F (10°C) Maximum Operating Temperature 100°F (38°C), 110°F (43°C) on 50 Hz. Models.
Note: Ice-O-Matic products are not designed for outdoor installation. Incoming Water Supply (See Plumbing Diagram for line sizing Page A10-A17)
Minimum incoming water temperature: 40°F (4.5°C) Maximum incoming water temperature: 100°F (38°C) Minimum incoming water pressure: 20 psi (1.4 bar) Maximum incoming water pressure: 60 psi (4.1 bar)
Note: If water pressure exceeds 60 psi (4.1 bar), a water pressure regulator must be installed.
Drains: All drain lines must be installed per local codes. Flexible tubing is not recommended.
Route bin drain, purge drain and water condenser drain individually to a floor drain. The use of condensate pumps for draining water is not recommended by Ice-O-Matic. Ice-O-Matic assumes no responsibility for improperly installed equipment.
Water Filtration: A water filter system should be installed with the ice machine. Clearance Requirements: Self contained air cooled ice machines must have a minimum of 6
inches (15cm) of clearance at the rear, top, and sides of the ice machine for proper air circulation. Stacking: If the ice machines are to be stacked, refer to the instructions in the stacking kit.
Ice-O-Matic does not endorse stacking air-cooled ice machines. Dispenser Application: A thermostatic bin control kit must be installed if the ICE Series ice
machine is placed on a dispenser. A bin top may or may not be required. (Exception is the
CD400 Dispenser) Electrical Specifications: Refer to the serial plate at the rear of the ice machine or the charts on
page A5, A6, A7 or A8.
Adjustments
Level the machine within 1/8 inch in all directions. Check the bin control for proper adjustment, Page F9 Check the water in the water trough for proper level, Page D1 Check the ice bridge for proper thickness, Page F4 Check the cam switch adjustment. Page F8 Check the water regulating valve adjustment if water cooled, Page E2
Page A9
ICE Series General Information
Electrical and Plumbing Requirements: ICEU150, ICEU220, ICEU205 and ICEU206
Page A10
ICE Series General Information

Electrical and Plumbing Requirements: ICEU150, 220, 225 and 226

Note: The ICEU150, ICEU220, ICEU225 and ICEU226 do not have a splash curtain.
These models utilize a thermostatic bin control in place of a mechanical bin switch.
Page A11
ICE Series General Information

Electrical and Plumbing Requirements: ICEU300 and 305 305

Note: The ICEU300 does not have a splash curtain.
This model utilize a thermostatic bin control in place of a mechanical bin switch.
Page A12
ICE Series General Information
Electrical and Plumbing Requirements: ICE0250, ICE0400, ICE0500, ICE0606, ICE0806 and ICE1006 (30 Inch Wide Cubers)
Page A13
ICE Series General Information
Electrical and Plumbing Requirements: ICE1406, ICE1806, ICE2106 (48 Inch Wide Cubers) Prior to January 2008
Page A14
ICE Series General Information

Electrical and Plumbing Requirements: ICE0320 and ICE0520 (22 Inch Wide Cubers)

Page A15
ICE Series General Information
Electrical and Plumbing Requirements: ICE1400, ICE1800 and ICE2100 Revision 3 (From January 2008)
Page A16
ICE Series General Information

Electrical and Plumbing Requirements: ICE1506 Remote

Page A17
ICE Series General Information

Remote Condenser Installation

For proper operation of the Ice-O-matic ice machine, the following installation guidelines must be followed. Failure to do so may result in loss of production capacity, premature part failure, and may void all warranties.

Installation Guidelines

Ambient operating temperatures: -20°F (-28.9°C) to 120°F (48.9°C) Maximum refrigerant line length: 60 ft. (18.29 Meters) Maximum vertical rise: 16 ft. (4.88 Meters) Minimum condenser height: ICE Series ice machine remote condensers must not be
installed more than 6 feet (1.3 meters) below the refrigerant line quick connects at the rear of the ice machine. No part of the refrigerant lines, between the ice machine and the remote condenser, should fall below this point. Condensers must have a vertical airflow.
Air Flow
Page A18
ICE Series General Information
The following remote ice makers incorporate the mixing valve in the condenser. This configuration allows up to a 100 foot calculated remote line set run. Reference the diagram below to calculate the maximum 100 foot line set run.
ICE Machine Model Number Remote Condenser Model Number
ICE2100R3 VRC5061B ICE1800R3 VRC5061B ICE1400R3 VRC2661B ICE1506HR2 VRC2661B ICE1006R3 VRC2061B ICE0806R3 VRC2061B ICE0606R3&4 VRC1061B ICE0500R3&4 VRC1001B
Limitations for new remote machines that have the mixing valve mounted in the condenser.
Maximum Rise is 35 feet. Maximum Drop is 15 feet. Maximum equivalent run is 100 feet.
Formula for figuring maximum equivalent run is as follows:
Rise x 1.7 + Drop x 6.6 + horizontal run = equivalent run.
Examples: 35 ft. rise x 1.7 + 40 ft. horizontal = 99.5 equivalent feet line run
35 ft. rise
40 ft. horizontal
Verify the ICE machine is compatible with the remote condenser. Some ice machines and some remote condensers may or may not have a Mixing Valve (Head Master). Only one valve is required per system. Kits are available to modify the condenser for compatibility. For more information contact your Ice-O-Matic Distributor.
34 ft. horizontal
10 ft. drop x 6.6 + 34 ft horizontal = 100 equivalent feet line run
Page A19
10 ft. drop
ICE Series General Information

How the ICE Machine Works

A general description of how the ICE Series cubers work is given below. The remainder of the manual provides more detail about the components and systems.
With the ICE/OFF/WASH switch in the ICE position, the compressor, water pump and condenser fan motor (when applicable) will energize starting the freeze cycle.
During the freeze cycle, water is circulated over the evaporator(s) where the ice cubes are formed. When the suction pressure has pulled down to the proper cut-in pressure of the timer initiate (pressure control), the contacts will close and energize the time delay module (timer). See Page F3 for proper cut-in pressures. At this time the cubes will close to completion.
The remaining portion of the freeze cycle is determined by the timer setting. The timer is pre-set at the factory to achieve the proper ice bridge thickness but may need to be adjusted upon initial start-up, see Page F4 for initial timer settings.
Once the amount of time on the timer has passed, the control relay will be energized and the machine will enter harvest. Power is now supplied to the water purge valve, hot gas valve, and the harvest motor. The water purge valve opens, and allows the water pump to purge the water remaining in the water, removing impurities and sediment. This allows the machine to produce clear ice cubes and keep mineral build up at a minimum. The hot gas solenoid opens allowing hot gas to go directly to the evaporator, heating the evaporator and breaking the bond between the evaporator and the ice slab.
The harvest assist motor, which is also energized during harvest, turns a slip clutch, which pushes a probe against the back of the ice slab. Once the evaporator has reached approximately 40°F (4.5°F) in temperature, the slip clutch overcomes the bonding of the ice to the evaporator and pushes the slab of ice off of the evaporator and into the storage bin. The clutch also actuates a switch that rides on the outer edge of the clutch. When the clutch completes one revolution, the switch is tripped and the machine enters the next freeze cycle.
When ice drops into a full bin during harvest, the splash curtain is held open which activates a bin switch shutting the machine off. When ice is removed from the bin, the splash curtain will close and the machine will come back on.
Page A20
ICE Series General Information

Undercounter Bin Removal-ICEU300 Series

The storage bin can be removed by: 1 Remove the lower grill.
2. Remove two screws securing bin to cabinet base.
3. Remove the thumbscrews from the back wall of the bin. 3. Remove the thumbscrews from the back wall of the bin.
4. Disconnect bin drain. 4. Disconnect bin drain.
5. Lift front of bin slightly and pull bin forward to remove. 5. Lift front of bin slightly and pull bin forward to remove.
3
2
Page A21
ICE Series General Information

Undercounter Bin Removal-ICEU150/200 Series

The storage bin can be removed by:
1. Remove the two screws at the rear of the top panel.
2. Remove the two screws from the front panel.
3. Remove two screws securing bin to cabinet base.
4. Disconnect bin drain.
5. Lift front of bin slightly and pull bin forward to remove.
1
2
4
5
3
Page A22
ICE Series General Information

Warranty Information

Every Ice-O-Matic machine is backed by a warranty that provides both parts and labor coverage.
PARTS LABOR
Two years on all parts* Two years on all components* Three years on all ICE Maker parts* Three years on all cube ICE Maker components* Five years on compressors* Five years on cuber evaporators*
Water Filtration System Extended Warranty Program
Purchase a new Ice-O-Matic IFQ or IFI Series Water Filtration System with a new ICE Series ICE Machine, replace the filter cartridge every 6 month and Ice-O-Matic will extend the limited cuber evaporator warranty to 7 years parts and labor.
New machine and filter must be installed at same time.
Must send in both the machine and water filter registration cards within 10 days of
installation.
Must send in additional registration card for each new filter installed. This must be done every 180 days (6 months) or less.
Program is available with all IFQ and IFI filter systems.
Replacement filter must be model number IOMQ or IOMWFRC.
Available in the USA and Canada only.
Warranty If, during the warranty period, customer uses a part for this Ice-O-Matic equipment other than an unmodified new part purchased directly from Ice-O-Matic, Ice-O-Matic Distributors, or any of its authorized service agents and/or the part being used is modified from its original configuration, this warranty will be void. Further, Ice-O-Matic and its affiliates will not be liable for any claims, damages or expenses incurred by customer which arises directly or indirectly, in whole or in part, due to the installation of any modified part and/or part received from an unauthorized service center. Adjustments are not covered under warranty.
Warranty Procedure Matic authorized representative travels to the installation address to perform warranty service, the service representative will advise customer the warranty is void. Such service call will be billed to the customer at the authorized service center’s then-applicable time and material rates.
If the customer is using a part that results in a voided warranty and an Ice-O-
Page A23
ICE Series General Information
Ice-O-Matic
Domestic & International Limited Warranty
Mile High Equipment LLC (the “Company”) warrants Ice-O-Matic brand ice machines, ice dispensers, remote condensers, water filters, and ice storage bins to the end customer against defects in material and factory workmanship for the following:
Cube ice machines,”GEM” model compressed ice machines ,” MFI” model flake ice machines and remote condensers. - Thirty-six (36) months parts and labor
“EF” and “EMF” model flake ice machines - Twenty-four (24) months parts and labor
CD model dispensers - Thirty-six (36) months parts and labor
An additional twenty-four (24) month warranty on parts (excluding labor) will be extended to all cube ice machine evaporator plates and compressors, “GEM” model compressed ice machine compressors, and “MFI” model flake ice machine compressors from the date of original installation. An additional thirty-six (36) month warranty on parts (excluding labor) will be extended to all “EF” and “EMF” model flake ice machine compressors from the date of original installation. The company will replace EXW (Incoterms 2000) the Company plant or, EXW (Incoterms 2000) the Company-authorized distributor, without cost to the Customer, that part of any such machine that becomes defective. In the event that the Warranty Registration Card indicating the installation date has not been returned to Ice-O-Matic, the warranty period will begin on the date of shipment from the Company. Irrespective of the actual installation date, the product will be warranted for a maximum of seventy-two (72) months from date of shipment from the Company.
ICE-model cube ice machines which are registered in the Water Filter Extended Warranty Program will receive a total of eighty-four (84) months parts and labor coverage on the evaporator plate from the date of original installation. Water filters must be installed at the time of installation and registered with the Company at that time. Water filter cartridges must be changed every six (6) months and that change reported to the Company to maintain the extended evaporator warranty.
No replacement will be made for any part or assembly which (I) has been subject to an alteration or accident; (II) was used in any way which, in the Company’s opinion, adversely affects the machine’s performance; (III) is from a machine on which the serial number has been altered or removed; or, (IV) uses any replacement part not authorized by the Company. This warranty does not apply to destruction or d amage caused by unauthori zed service, using other than Ice-O-Matic authorized replacements, risks of transportation, damage resulting from adverse environmental or water conditions, accidents, misuse, abuse, improper drainage, interruption in the electrical or water supply, charges related to the replacement of non­defective parts or components, damage by fire, flood, or acts of God.
This warranty is valid only when installation, service, and preventive maintenance are performed by a Company-authorized distributor, a Company­authorized service agency, or a Company Regional Manager. The Company reserves the right to refuse claims made for ice machines or bins used in more than one location. This Limited Warranty does not cover ice bills, normal maintenance, after-install adjustments, and cleaning.

Limitation of Warranty

This warranty is valid only for products produced and sh ipped from the Company after January, 2007. A product produced or installed before that date shall be covered by the Limited Warranty in effect at the date of its shipment . The liability of the Company for breach of this warranty shall, in any case, be limited to the cost of a new part to replace any part, which proves to be defective. The Company makes no representations or warranties of any character as to accessories or auxiliary equipment n ot manufactured by the Company.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CUSTOMER. MILE HIGH EQUIPMENT SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATI ON TO THE LENGTH OF THIS WARRANTY.
Filing a Claim All claims for reimbursement must be received at the factory within 90 days from date of ser vice this time period will be void. The model, the serial number and, if necessary, proof of installation, must be included in the claim. Claims for labor to replace defective parts must be included with the part claim to receive consideration. Payment on claims for labor will be limited to the published labor time allowance hours in effect at the time of repair. The Company may elec t to require the return of components to validate a claim. Any defective part returned must be shipped to the Company or the Company-authorized distributor, transportation charges pre-paid, and properly sealed and tagged. The Company does not assume any responsibility for any expenses incurred in the field incidental to the repair of equipment covered by this warranty. The decision of the Company with respect to repair or replacement of a part shall be final. No person is authorized to give any other warranties or to assume any other liability on the Company’s behalf unless done in writing by an officer of the Company.
GOVERNING LAW
This Limited Warranty shall be governed by the laws of the state of Delaware, U.S.A., excluding their conflicts of law principles. The United Nations Convention on Contracts for the International Sale of Goods is hereby excluded in its entirety from application to this Limited Warranty.
Mile High Equipment LLC, 11100 East 45
Parts and Labor
Ice storage bins -Twenty-four (24) month parts and labor
IOD model dispensers - Twenty-four (24) months parts, Twelve (12) months
labor
Water filter systems - Twelve (12) months parts a nd labor (not including filter cartridges)
to be eligible for credit. All claims outside
th
Avenue, Denver, Colorado 80239 (303) 371-3737
January 2007
Page A24
ICE Series Scheduled Maintenance

Maintenance

Note: Maintenance should be performed by an Ice-O-Matic trained Service Technician. Electrical shock and/or injury from moving parts inside this
machine can cause serious injury. Disconnect electrical supply to machine prior to performing any adjustments or repairs.
Failure to perform the required maintenance at the frequency specified will void warranty coverage in the event of a related failure. To insure economical, trouble free operation of the machine, the following maintenance is required every 6 months.
Maintenance Procedure
1. Clean the ice-making section per the instructions below. Cleaning should be performed a minimum of every 6 months. Local water conditions may require that cleaning be performed more often.
2. Check ice bridge thickness. See page F4 for proper thickness and adjustment procedure.
3. Check water level in trough. See page D1 for proper water level and adjustment.
4. Clean the condenser (air-cooled machines) to insure unobstructed air flow.
5. Check for leaks of any kind: Water, Refrigerant, Oil, Etc.
6. Check the bin switch for proper adjustment. See page F9 for bin switch adjustment.
7. Check the cam switch adjustment. See page F8 for cam switch adjustment.
8. Check the water valve (water-cooled machines) for proper adjustment. See page E2.
9. Check all electrical connection.
10. Oil the fan motor if the motor has an oil fitting. (Self contained air-cooled models only)
Cleaning and Sanitizing
1. Harvest problems may occur if the following procedures are not performed every 6 months.
2. Remove the ice machine front panel.
3. Make sure that all the ice is off of the evaporator. If ice is being made, wait for cycle completion, then turn the machine “OFF” at the ICE/OFF/WASH selector switch.
4. Remove or melt all ice in the storage bin.
Page B1
ICE Series Scheduled Maintenance

Cleaning and Sanitizing (continued)

5. Add recommended amount of approved Nickel Safe ice machine cleaner to the water trough according to label instructions on the container.
6. Initiate the wash cycle at the ICE/OFF/WASH switch by placing the switch in the “WASH” position. Allow the cleaner to circulate for approximately 15 minutes to remove mineral deposits.
7. Depress the purge switch and hold until the ice machine cleaner has been flushed down the
drain and diluted by fresh incoming water.
8. Terminate the wash cycle at the ICE/OFF/WASH switch by placing the switch in the “OFF”
position. Remove the splash curtain and inspect the evaporator and water spillway to assure all mineral residue has been removed.
9. If necessary, wipe the evaporator, spillway and other water transport surfaces with a clean soft
cloth to remove any remaining residue. If necessary, remove the water distribution tube, disassemble and clean with a bottlebrush, see page D2. Reassemble all components and repeat steps 4 through 7 as required to remove residue.
10. Turn OFF ice machine water supply and clean the water trough thoroughly to remove all scale or slime build-up. If necessary, remove the water trough to reach all splash areas and float.
11. Prepare 1½ to 2 gallons (5.7 to 7.5 liters) of approved (EPA/FDA) sodium hypochloride food equipment sanitizer to form a solution with 100 to 200 ppm free chlorine yield.
12. Add enough sanitizing solution to fill the water trough to overflowing and place the ICE/OFF/WASH switch to the “WASH” position and allow circulation to occur for 10 minutes and inspect all disassembled fittings for leaks. During this time, wipe down all other ice machine splash areas, plus the interior surfaces of the bin, deflector and door with the remaining sanitizing solution. Inspect to insure that all functional parts, fasteners, thermostat bulbs (if used), etc. are in place.
13. Depress the purge switch and hold until sanitizer has been flushed down the drain. Turn ON the ice machine water supply and continue to purge to the diluted sanitizing solution for another 1 to 2 minutes.
14. Place the ICE/OFF/WASH switch to the “ICE” position and replace the front panel.
15. Discard the first two ice harvests.
Page B2

ICE Series Winterizing Procedures

Winterizing Procedures Important!
Whenever the ice machine is taken out of operation during the winter months, the procedure below must be performed. Failure to do so may cause serious damage and will void all warranties.
1. Turn off water to machine.
2. Make sure all ice is off of the evaporator(s). If ice is being made, initiate harvest or wait for cycle completion.
3. Place the ICE/OFF/WASH switch to the “OFF” position.
4. Disconnect the tubing between the water pump discharge and water distribution tube.
5. Drain the water system completely.
6. On water cooled machines, hold the water regulating valve open by prying upward on the water valve spring with a screwdriver while using compressed air to blow all the water out of the condenser.
7. Remove all of the ice in the storage bin and discard.
Page B3
ICE Series Cabinet Care Cleaning stainless steel
Commercial grades of stainless steel are susceptible to rusting. It is important that you properly care for the stainless steel surfaces of your ice machine and bin to avoid the possibility of rust or corrosion. Use the following recommended guidelines for keeping your stainless steel looking like new:
1. Clean the stainless steel thoroughly once a week. Clean frequently to avoid build-up of
hard, stubborn stains. Also, hard water stains left to sit can weaken the steel's corrosion resistance and lead to rust. Use a nonabrasive cloth or sponge, working with, not across, the grain.
2. Don't use abrasive tools to clean the steel surface. Do not use steel wool, abrasive sponge
pads, wire brushes or scrapers to clean the steel. Such tools can break through the "passivation" layer - the thin layer on the surface of stainless steel that protects it from corrosion.
3. Don't use cleaners that use chlorine or chlorides. Don't use chlorine bleach or products like
Comet to clean the steel. Chlorides break down the passivation layer and can cause rusting.
4. Rinse with clean water. If chlorinated cleansers are used, you must thoroughly rinse the
surface with clean water and wipe dry immediately.
5. Use the right cleaning agent. The table below lists the recommended cleaning agents for
common stainless steel cleaning problems:

Cleaning Activity Cleaning Agent Method of Application

Routine cleaning Soap, Ammonia, Windex, or Apply with a clean cloth detergent with water. or sponge. Rinse with Fantastik, 409 Spic’nSpan clean water and wipe dry.
Liquid are also approve for Stainless Steel.
Removing grease or Easy-Off or similar oven Apply generously, allow fatty acids cleaners. to stand for 15-20 minutes. Rinse with clean water. Repeat as required.
Removing hard water spots Vinegar Swab or wipe with clean cloth. and scale. Rinse with clean water and
dry.
Page B4