Product Specification
CATEGORY 6 600 UTP CMP SOLID CABLE
Package Includes
A. Category 6 UTP CMP Solid Cable, 1000 feet
Features and Benefits
• Exceeds TIA 568-C.2 Category 6 standard
• Easy to dispense cable with Reelex design box, saving your time and energy on the job site
• Convenient sequential footage markings for usage tracking
• UL verified for guaranteed +5dB over ANSI/TIA-568-C.2 standard performance
requirements: NEXT (min), PSNEXT (min), ELFLEXT (min), PSELFLEXT (min)
• UL listed for plenum (CMP) applications
ITEM NUMBER DESCRIPTION UPC NUMBER
ICCABP6EBL C6E 600 UTP SLD CBL, 23G, 23G, 4P, CMP, 1K BL 6 33758 02986 5
ICCABP6EGN C6E 600 UTP SLD CBL, 23G, 23G, 4P, CMP, 1K GN 6 33758 03750 1
ICCABP6EGY C6E 600 UTP SLD CBL, 23G, 23G, 4P, CMP, 1K GY 6 33758 03002 1
ICCABP6EWH C6E 600 UTP SLD CBL, 23G, 23G, 4P, CMP, 1K WH 6 33758 03004 5
ICCABP6EYL C6E 600 UTP SLD CBL, 23G, 23G, 4P, CMP, 1K YL 6 33758 03006 9
Part Number: ICCABP6EXX
Rev: G
Page 1 of 2
© Copyright 2013, ICC. This document and the designs, specifications and information contained herein are the property of ICC. Reproduction, modification,
alteration or unauthorized use without ICC’s approval is strictly prohibited. ICC and the ICC logo are registered trade name and trademark of ICC. All rights reserved.
I 888-ASK-4ICC icc.com csr@icc.com I
Product Specification
Specifications
NOTE: UNLESS OTHERWISE SPECIFIED
1. STANDARD:
A. ANSI/TIA 568-C.2
B. ANSI/TIA 862 (BUILDING AUTOMATION)
C. ISO/IEC 11801 Ed. 2.0 (CLASS E)
D. ICEA S-102-700 (CATEGORY 6)
E. NEC/CEC Type CMP (NFPA 262)
F. ROHS COMPLIANT DIRECTIVE 2002/95/EC
G. UL 444
2. CONSTRUCTION:
A. CONDUCTOR: 23 AWG SOLID BARE ANNEALED COPPER
B. JACKET: LOW-SMOKE, FLAME-RETARDANT PVC
C. INSULATION: FLUOROPOLYMER
D. OUTER DIAMETER (IN): 0.225”
3. ELECTRICAL & PHYSICAL PROPERTIES:
A. DC RESISTANCE (MAX)OHMS/100 M (328 FT) @ 20˚C: 8.9
B. DC RESISTANCE UNBALANCE (MAX)INDIVIDUAL PAIR %: 3.0
C. DELAY SKEW (MAX) NS/100M: 35
D. NOM. VELOCITY OF PROPAGATION (NVP) % SPEED OF LIGHT: 70%
E. CHARACTERISTIC IMPEDANCE FREQUENCY (F): 1-500 MHZ: 100 ± 15 OHMS
CATEGORY 6 600 UTP CMP CABLE ELECTRICAL PERFORMANCE (100 METER LOOP)
INSERTI
FREQUE
NCY
(MHz)
1 2 20 77.3 79.3 77.3 75.3 72.8 69.8
4 3.8 23.6 68.3 70.3 66.5 64.5 60.8 57.8
10 6 26 62.3 64.3 58.3 56.3 52.8 49.8
16 7.6 26 59.2 61.2 53.7 51.7 48.7 45.7
20 8.5 26 57.8 59.8 51.3 49.3 46.8 43.8
31.25 10.7 25 54.9 56.9 46.2 44.2 42.9 39.9
62.5 15.4 23.5 50.4 52.4 37 35 36.9 33.9
100 19.8 22.5 47.3 49.3 29.5 27.5 32.8 29.8
150 25.2 21.6 44.4 46.4 21.3 19.3 29 26
200 29 21 42.8 44.8 15.8 13.8 26.8 23.8
250 32.8 20.5 41.3 43.3 10.5 8.5 24.8 21.8
350 39.8 19.8 39.1 41.1 -- -- 21.9 18.9
500 48.9 19 36.8 38.8 -- -- 18.8 15.8
550 51.8 18.8 36.2 38.2 -- -- 18 15
600 54.5 18.6 35.6 37.6 -- -- 17.2 14.2
ON
LOSS
MAX.
(dB/10
0M)
LOSS
MIN.
(dB)
PSNEXT
MIN.
(dB)
NEXT
MIN.
(dB)
ACR*
MIN.
(dB)
PSACR*
MIN.
(dB)
ACRF
MIN.
(dB/10
0M)
PS
ACRF
MIN
(dB/10
0M)
For warranty information, go online to icc.com/warranty.
Part Number: ICCABP6EXX
Rev: G
Page 2 of 2
© Copyright 2013, ICC. This document and the designs, specifications and information contained herein are the property of ICC. Reproduction, modification,
alteration or unauthorized use without ICC’s approval is strictly prohibited. ICC and the ICC logo are registered trade name and trademark of ICC. All rights reserved.
I 888-ASK-4ICC icc.com csr@icc.com I
Part No: ICCABP6EXX
Rev: G