IC Pressure Governor, FPG Quick Start Manual

Page 1
Pressure Governor Quick Start Guide
Use the appropriate Innovative Controls 4000675 series wiring harnesses for your application. Install the Fire Pressure Governor wiring harnesses on the rear of the unit and connect the vehicle power, interlocks, pump pressure sensors, and engine CAN network or analog control signals to the field wiring side of the cable harnesses. The illustration below shows the six different standard FPG cable harnesses:
Models 3050621, 3050622, 3050623, and 3050624
1
2
3
4
5
6
7
8
9
ENGINE (+) REF
THROTTLE READY HIGH IDLE
DISCHARGE SENSOR GND DISCHARGE SENSOR REF DISCHARGE SENSOR SIG
ENGINE SIGNAL ENGINE (-) REF
PUMP ENGAGED
DELAY RELAY COM DELAY RELAY N.O.
Pin Name
Red
White White
Black
Red White
Yellow
Black
White
Orange
Blue
Wire
THROTTLE READY PUMP ENGAGED HIGH IDLE
Name
White White White
Wire
Interlocks
ENGINE (+) REF. ENGINE (-) REF. ENGINE SIGNAL DELAY RELAY COM. DELAY RELAY N.O.
Name
Red
Black
Yellow
Orange
Blue
Wire
Analog Control
CABLE
4000675-03
CABLE
4000675-02
CABLE
4000675-04
Models 3050621 and 3050623
1
2
3
4
5
6
SYSTEM POWER SYSTEM GROUND ALARM SAE CAN HI SAE CAN LO SAE CAN SHIELD
Pin Name
Red Black
Blue
Yellow Green Shield
Wire
SYSTEM POWER SYSTEM GROUND ALARM
Name
Red
Black
Blue
Wire
Power and Alarm
SAE CAN HIGH SAE CAN LO SAE CAN SHIELD
Name
Yellow Green Shield
Wire
SAE J1939 CAN
CABLE
4000675-01
12 Pin Key A
12 Pin Key B
6 Pin
SYSTEM POWER SYSTEM GROUND ALARM
Name
Red
Black
Blue
Wire
Power and Alarm
IC CAN HIGH IC CAN LO IC CAN SHIELD
Name
Yellow Green Shield
Wire
IC J1939 CAN
SENSOR GROUND SENSOR +5 REF. SENSOR SIGNAL
Name
Black
Red
White
Wire
Intake Sensor
CABLE
4000675-05
IC CAN HIGH IC CAN LO IC CAN SHIELD
Name
Yellow Green Shield
Wire
IC J1939 CAN
CABLE
4000675-06
SAE CAN HIGH SAE CAN LO SAE CAN SHIELD
Name
Yellow Green Shield
Wire
SAE J1939 CAN
Models 3050622, and 3050624
1
2
3
4
5
6
7
8
9
SYSTEM POWER SAE CAN HI SAE CAN SHIELD IC CAN HI INTAKE SENSOR GND INTAKE SENSOR REF INTAKE SENSOR SIG IC CAN SHIELD IC CAN LO ALARM OUT SAE CAN LO SYSTEM GROUND
Pin Name
Red
Yellow Shield Yellow
Black
Red White
Shield Green
Blue
Green
Black
Wire
SENSOR GROUND SENSOR +5 REF. SENSOR SIGNAL
Name
Black
Red
White
Wire
Discharge Sensor
MOUNTING
WIRING
During power up the FPG displays the installed software version, and the current date and time. After initialization the FPG goes into READY mode by default.
Verify that the Throttle Ready and OK to Pump interlocks operate correctly using the LED indicators and Status display on the front panel of the FPG. The Status display will show OK to PUMP when both the Throttle Ready and Pump Engaged interlock inputs are active. If the engine is communicating correctly with the FPG the engine speed will be shown in the RPM display, otherwise the Status display will show NO J1939 ENGINE COMM.
The Engine Temperature, Oil Pressure, and Transmission Temperature, and Battery icons will all be green if their conditions are normal. A yellow or red icon is an indicates a problem and additional information will be shown on the Status display.
Press the PRESSURE button to place the FPG in pump pressure control mode.
Press the RPM button to place the FPG in engine speed control mode. Use the rotary knob, or the + and – buttons to adjust the pump pressure or engine speed setpoints.
The PRESET button is used to set the pump pressure or engine speed to a pre-pro­grammed setting. The IDLE button causes the FPG to slow the engine to curb idle speed and return to READY mode.
(continued on back)
OPERATION
4.00
3.50
0.21 DIA. TYP.
5.75
0.50
RAD.
TYP.
The panel cutout for the Fire Pressure Governor (FPG) is shown below in inches. Use four #10 screws to mount the unit to the pump panel.
PRESSURE SENSORS
Use Innovative Controls pressure sensor part numbers 3050471 or 3050472 for 300 or 600 PSI full scale discharge pressure measurement. Use the 3050473 or 3050474 pressure sensor for 300 or 600 PSI intake pressure measurement. Install the pump discharge pressure sensor on the discharge manifold side of the pump. Install the pump intake pressure sensors on the intake manifold side of the pump when applicable.
Page 2
Innovative Controls Inc. 560 Braddock Avenue East Pittsburgh,PA 15112 412-824-2264 Fax: 412-824-2339
CONFIGURATION MODE
The FPG has configuration parameters that are used to customize the operation for a variety of pumps, engine controls, and fire department Standard Operating Procedures.
With the FPG in READY mode, press and hold the PRESET and IDLE or STATUS buttons for five seconds to place the FPG into Configuration mode. When the FPG is in Configuration mode the engine speed display will show a “P” and the parameter number being edited. Pressing the RPM mode button increments the displayed parameter number, the PRESSURE button decrements the parameter number. Use the knob or the + and – buttons to adjust the displayed parameter.
Press the PRESET button to store changes made to a configuration parameter. Press IDLE or STATUS to exit the Configuration mode and return to the Ready mode. Before operating the FPG it may be necessary to adjust the following configuration parameters:
16 - DISCHARGE SENSOR = 300 or 600PSI 18 – DISCHARGE SENSOR ZERO CALIBRATION
There are currently 74 different configuration parameters listed below.
Parameter
Number
Name
Parameter
Number
Name
1 UNITS 2 PRESET RPM 3 PRESET PSI 4 HIGH IDLE 5 SENSITIVITY 6 RPM GAIN 7 PRESS GAIN 8 ALLOW PRESET 9 SMOOTHING 10 PSET MIN 11 NUDGE LIMIT 12 LAG DELTA PSI 13 ROUNDING 14 IDLE RPM 15 PSI TIME-OUT 16 DISCHARGE SENSOR 17 INTAKE SENSOR 18 DISCHARGE ZERO CAL 19 INTAKE ZERO CAL 20 DISCHARGE CALIBRATION 21 INTAKE CALIBRATION 22 ENGINE TYPE 23 BRIGHTNESS 24 DISPLAY TEST 25 ALERT TONE 26 DISPLAY 27 VOLTS OFFSET 28 KNOB INC DIRECTION 29 COM STATUS 30 BAUD RATE 31 FACTORY DEFAULT 32 ENGINE ID 33 DAY 34 MONTH 35 YEAR 36 HOUR 37 MINUTE
38 PUMP HOURS 39 WARNINGS 40 WARNING TEMP 41 CRITICAL TEMP 42 WARNING PSI 43 CRITICAL PSI 44 HPG MODE 45 SOURCE ID 46 OK2PUMP 47 HI IDLE MODE 48 INTERLOCKS 49 AUTO MODE 50 DIR PRESET 51 PRESS P-GAIN 52 PRESS I-GAIN 53 PRESS D-GAIN 54 SPEED P-GAIN 55 SPEED I-GAIN 56 SPEED D-GAIN 57 TSC1 MODE 58 SPN 695 59 SPN 696 60 SPN 897 61 PN 3349 62 SPN 3350 63 TSC1 RAMP 64 RPM MAX 65 POC ASSERT 66 IDLE STEPS 67 DITHER 68 ECM MSG TX 69 ENGINE MSG 70 BCM1 VER 71 SCANIA MODE1 72 SCANIA TYPE 73 SCANIA MODE2 74 VOLVO CONTROL
Loading...