M e s s t e c h n i k
PC - Station for wireless
Data transmission
INSTRUCTION MANUAL
IBRit - rf1 - usb
Document No. : D1F604 001
Version : April 2006
Copyright :
IBR
Messtechnik GmbH & Co. KG
Manual IBRit - rf1 - usb
Contents
1. Introduction
1.1 General information ................................................................................................................ : 3
1.2 Features .................................................................................................................................. : 4
1.3 Technical data ......................................................................................................................... : 4
2. Setting up the system
2.1 Delivered items ....................................................................................................................... : 5
2.2 System Conditions .................................................................................................................. : 5
2.3 Installation of the USB –
2.4 Function test of the IBRit
3. Programming of gauge radio modules with the programme IBR_SimKey ............................ : 9
4. Confirmation signals of the IBRit - rf1 gauge radio modules ................................................... : 10
5. Safety Instructions ........................................................................................................................ : 11
6. Declaration of conformity ............................................................................................................ : 12
7. Guarantee ..................................................................................................................................... : 13
We reserve the right to change the design and technical data contained in our documentation without notifying
our customers. IBR is not obliged to notify changes of the products to previous buyers.
IBRit is a registered trademark of IBR.
EXCEL and WORD are registered trademarks of Microsoft Corporation.
All parts of this document must not be reproduced without written permission from IBR.
driver for the IBRit - rf1 - usb module................................................. : 5
- rf1 radio module with the programme IBR_SimKey ..................... : 6
2
Manual IBRit - rf1 - usb
1. Introduction
1.1 General Information
The IBRit - rf1 radio module series allows the wireless transmission of measured values from
gauges to a PC with USB - connector.
On the PC side the wireless communication with the gauges occurs via the radio module IBRit - rf1 - usb.
The module is connected via a USB-Slot to the PC and allows the communication with 1 ... 120 gauge radio modules.
The assignment of the data from the different gauges occurs by address numbers. The address number
and other individual radio module settings for the particular gauge type can be transmitted from the PC to
the gauge radio modules and are stored there.
The corresponding PC-Software IBR_SimKey is included in the delivery of the IBRit - rf1 - usb.
The transmission of a measured value is triggered by pressing the data key on the gauge or radio module.
The gauge radio module completes the measuring value by the address number ( sender ), one
communication control word and a double checksum. The special data coding and the direct
communication between PC and the radio modules on the gauges guarantee absolute data security.
A transmission error, i.e. caused by a radio interference, is detected by the communication protocol
between PC and gauge radio module. The data transmission is automatically repeated within 0,01 ... 0,08
seconds up to 3 times. A successful data transmission is automatically confirmed to the user by a green
flashing light and short beep tone on the gauge radio module. If the measuring value could not be received
by the PC, then a red LED is flashing and two longer beep tones are informing the user about the error.
More information over the different error codes you will find on the page 10.
The maximum transmission distance depends strongly on the environment and can be several meters up
to 200 meters.
The output of the received measurement values can be taken place in nearly every software, because the
programme IBR_SimKey outputs the measurement values over the keyboard buffer.
3
Manual IBRit - rf1 - usb
1.2 Features
PC radio station IBRit - rf1 - usb with USB interface for communication with at maximum
120 gauge radio modules
Gauge radio modules IBRit - rf1 - opto for gauges with Opto RS232 interface
IBRit
IBRit
IBRit
- rf1 - digi for gauges with Mitutoyo interface
- rf1 - mahr for gauges with Mahr interface
- rf1 - 232 for gauges with RS232 interface
High data security by double and independent check sum
Optical and acoustical transmission confirmation of the gauge radio modules
Distance up to 200 m
1.3 Technical Data
Mechanical Characteristics
Case Plastic
Wall holder Wall holder for plugging in the IBRit - rf1 - usb. The wall
holder contains two holes for the mounting with screws
Dimensions with antenna W x H x D / Weight 47 x 275 x 30 mm / ca. 175 g
Electrical Characteristics
Power supply By USB port
Current consumption max. 40 mA
Transmission frequency 433,926 MHz
Frequency range ± 15 KHz
Modulation type FSK
Output power @400 Ω
Sensitivity @400 Ω
Transmission speed 9600 baud
Working temperature range 0 ... 50°C
Storage temperature range -30 ... +60°C
Protection class IP50 ( CEI / IEC 529 )
CE conformity Harmonised standards EN 300 220
FCC FCC ID : T6T-604001
+10 dBm
-105 dBm
Environment conditions
Measurement data
Specific standards
4