The appliance consists of a storage case with a mirror, a pair of depilatory tweezers with two keys for gripping the hair, a pair of coil tweezers, a
power pack and a cleaning brush.
OFF
HI
MED
LO
12
WORKING PRINCIPLE
With this epilator you achieve along-lastingdepilatoryeffectwhenusingitinthe home.
By meansof the highfrequency when correctlyapplied, besides thehair,the hair rootis removed sothat the hair does not grow again. If correctly
used the depilation is a processfreeofpainandchemicals.
No harmful electric current is emittedbythecoiltweezers.
The way of functioning of the appliance is based on a high frequency, which is safe for human beings, in order to destroy the hair root and the
tactile papilla.
This is achieved through the changeofthepHvalueinthe hair follicles.
It is this pH value which,beyondtheapplicationoftheappliance, inhibits the growth of hair.
Total removal of the hair withoutanysubsequentre-growthcan only be achieved after repeatedremoval.Any hairthenpossiblygrowing is already
lighter-coloured and thinner.
Short hairsafter heat treatment
before removal. Several hairs at the same time can be gripped by means of the coil tweezers and removed. The depilatory head and the coil
tweezers can be easily replaced.
In the case of long hair, it is advisable to first use a lady shaver in order to shorten the hairs to a favourable length for removal by the Beauty
Forever.
are most successfully removedof the appropriate region (bath/hot compress).Long hairs shouldbe shortened
13
HANDLING
Fit the connecting cableon the case and plug the power pack intothe socket. Now the luminous diode lights up showing"OFF". The appliance is
ready for use.
You can choose between:
for low current flow (sensitive skinareasandsmallesthairs)
• LO
•for the medium stage (with normallycompatibleskinandnormalhairgrowth)
Med
•for higher current flow (insensitive skinareasandstronghairforms)
HI
In any case, itisrecommendedthatthe various stages, starting withthelowest,betested, in order to find thepreferredandmost pleasant intensity
with the best result depending onone'sownskinandhairtype.
Depilation process:
1. Clean and warm up the appropriatepartofthebody(bath,compress, infrared light)
2. Selection of the depilation appliance (tweezerheadorcoiltweezers)
3. With the depilation appliance grip thehair(s)bymeansofthekeys
4. Keep the keys of the depilatorytweezersdepressedforabout30seconds (the luminous diode on the tweezersthenshinesmorebrightly)
5. Carefully pull out the hair inthedirectionofthegrowthdirection.
Should the hair not be loosened without pain the first time, please repeat the application once more. Probably this hair has a particularly strong
root or even several root canals.
If necessary,pleaseincreasethecurrentintensity and carry out a new test.
14
CHANGING THE TWEEZER HEAD
The depilatory tweezers are best fortheremovalofindividualhairs.Thecoiltweezers are suitable for the simultaneous removalofseveralhairs.
1. Pull off tweezer head carefully towards thefrontandpressunlockingkey.
2. Withdraw the coil or depilatory tweezers
3. Push on the appropriate tweezers andtweezerheadagain
15
T
ECHNICAL SPECIFICATION
Mains operation:
•230 V / 50 cycles
Appliance size:
•55 mm x 170 x 175
MPORTANT NOTES
I
Warning:thedevice must not be used during pregnancy!
Persons with cardiac pacemakers, cardiac diseases, epilepsy, diabetes miletus, multiple sclerosis, skin diseases, after operations and women
wearing spirals should not use theappliance.
The following skin regions are tobeavoided:
• Scars, naevi, open histological lesions,inflamedorsunburntskin
•Skin areas covered by make-up
The appliance should be used onlyinencloseddryrooms!
Should you feel ill at ease during the application or if skin irritation occurs after use of the appliance please consult a doctor. The use of the
appliance does not constitute a risk,youcanremovehairsfromall areas of skin with it. Pleaseneverthelessstoreitoutofreachof children.
In the event of visible damagedonotputtheapplianceinto operation. Send it to the servicecentreshowninthelist.
16
C
ARE OF THE APPLIANCE
You can wipe the appliance down with a damp cloth and then wipe it dry only in the switched-off state,. With the
enclosed brush you can clean thedepilationcoilonthetweezers.Do not use any aggressive cleansers andneverimmersetheapplianceinwater.
OSSIBLE FAULTS
P
Please ensure correct connection and afirmfitoftheconnectingcables.
No removal of hair: try again,you have possiblynot gripped thehair correctly in the tweezers. Possibly thehair is toolong and dueto its thickness
requires a longer response time for the current or the current intensity is too low. If you cannot eliminate the problem that has occurred after
changing the points listed above, pleasecontact:
ibp Service Center
please look at Guarantee
For your own safety do not carry out any repairs of your own on the appliance!
disconnected from the mains
17
GUARANTEE
Your epilator was checked to ensureitsfaultlessqualitybeforedespatch.
Please send the appliance for checking or repair together with the purchase document or receipt and the description of the faults and/or of the
desired check to the address below.
From the date of purchase (date on the purchase document) repairs will be carried out free of charge for 24 months, if your appliance should be
defective due to a production ormaterialfault.
The guarantee does not cover anydamageoccurringasaresultof faulty operation, improper treatment, storage andcareorunusualinfluences.
All further claims as well asdamagesshalllikewisebeexcluded.
Should you haveanyreason to avail yourself ofthe warranted services under theguarantee,send the appliance withtheguarantee documents to
the customer service department:
International Business Products Limited
6 Newfield Court, West Houghton, Bolton BL5 3 SA
England
Phone: +44(0) 19 42 - 8196 95
Head office:
ibp innovative business promotion GmbH
Botzstrasse 6
D-07743 Jena
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.