IBM UPS 3000XLV - IBM UPS 3000XHV
UNINTERRUPTIBLE POWER SUPPLY - QUICK INSTALLATION GUIDE
1: HARDWARE INSTALLATION
Attention: Read the Safety Instructions before installing the UPS.
The UPS and battery modules are heavy. Select a location sturdy enough to handle the weight.
Installing the UPS in a Rack, Connecting the Battery and Attaching the Front Bezel
Note: Illustrations in this document might differ slightly from the hardware.
Step 1
Connect the display bezel.
Rear: Connect
Step 4 Step 5Ste
See the Rail Installation Diagram that is
included in the Rail Kit.
Make sure the rack will not tip.
Custom Hex Head
10-32/ M6 x .5”
4
Step 2
Attach the mounting brackets.
Step 3
To lighten the UPS, remove the battery module before mounting.
Flat Head
8-32 x .375”
4
Philips Pan Head
8-32 x .375”
Reinstall the battery. Connect the battery to the UPS, and
attach the front bezel.
Philips Pan Head
8-32 x .375”
(A)
Tower Configuration
Step 1
Connect the battery to the UPS, and
attach the front bezel.
(A)
1
2
(B)
Step 2
Remove the rail guides from the UPS.
1
(B)
Step 3
Connect the display bezel.
Rear: Connect
4
Philips Pan Head
10-32 x .3125”
2
02R2718
Step 4
Rotate and attach the display bezel.
(A)
Step 5
Attach the top panels and mounting stabilizers.
(B)
Philips Pan Head
8-32 x .375”
4
Philips Pan Head
8-32 x .375”
1
(A)
Step 6
Rotate the unit to tower position.
(B)
Rear Panel Components
3000XLV Model
5
6
7
8
9
10
1
2
13
1
12
2
INDEX ITEM DESCRIPTION
1 & 2 Serial Port & USB Port
3 Voltage Selection Switch See UPS Operation & Setup Guide/Setting the Nominal Voltage.
4 Site Wiring Fault LED See UPS Operation & Setup Guide/Troubleshooting.
5 Network Port Manage the UPS via the Embedded Network Module.
6 Network Reset Button Reset the Embedded Network Module.
7 Extend Run Battery Pack Con-
8 Input Cord
9, 10 &
11
12, 13 &
14
3
nector
Outlet Banks 1, 2 & 3 Separate outlet banks are controlled by the Embedded Network
Circuit Breakers for Outlet Banks
1, 2 & 3
4
Power management software and interface kits can be used with the
UPS. Use only interface kits supplied or approved by IBM.
Use the supplied serial cable to connect to the serial port. DO
NOT use a standard serial interface cable since it is incompatible
with the UPS connector.
Serial and USB ports cannot be used simultaneously.
See Extend Run Battery Pack Operation and Setup Guide.
See UPS Operation & Setup Guide/Startup.
Module. See Embedded Network Module CD.
See UPS Operation & Setup Guide
3000XHV Model
11
/Troubleshooting.
3
14
5
INDEX* ITEM DESCRIPTION
1 Input Circuit Breaker
2 Input Connector
3, 4 & 5 Outlet Banks 1, 2 & 3 Separate outlet banks are controlled by the Embedded Network
*Exceptions from the 3000XLV are indicated here.
See UPS Operation & Setup Guide
See
UPS Operation & Setup Guide/ Startup.
Module. See Embedded Network Module CD.
4
/Troubleshooting.
2