Welcome.
Thank you for buying an IBM server. is based on the X-Architecture technology, and it features superior performance, availability, and affordability.
This server contains information for setting up and configuring your server.
For detailed information about your server, view the publications on the
Your server
Installation Guide
Documentation CD.
Did the server
start correctly?
Ye s
Turn off the server and install options.
Install the server in the rack cabinet
and cable the server and options;
then, restart the server.
Did the server start correctly?
Ye s
Use the IBM
ServerGuide program
to set up and
configure hardware.
Was the
server setup
completed?
No
No
No
Go to the Server Support
flow chart on the reverse
side of this page.
Go to the Server Support flow chart on the reverse
side of this page.
You can also find the most current information about your server at http://www.ibm.com/ support/ xseries/index.html
servers/eserver/support/
.
Ye s
Use
ServerGuide to
install the operating
system?
Ye s
Install applications, such as IBM systems management software and IBM ServeRAID programs
The server is ready to use.
Go to
http://www.ibm.com/support/mysupport/
to register the server.
No
Go to the Web for instructions:
http://www.ibm.com/support/
servers/eserver/support/ xseries/index.html
Server Support
Is the server working
correctly?
Ye s
No
Check all cables for loose connections and verify that all optional devices you installed are on the ServerProven list at
http://www.ibm.com/servers/eserver/ serverproven/compat/us/.
Is the problem
solved?
Ye s
No
Register the server. Go to
http://www.ibm.com/support/mysupport/.
View information about IBM Support Line at
http://www.ibm.com/services/sl/products/
or view support telephone numbers at
http://www.ibm.com/planetwide/.
See the troubleshooting information that comes with the server to determine the cause of the problem and the action to take.
Is the problem
solved?
Ye s
No
Update the firmware to the latest level. You can download firmware from
http://www.ibm.com/servers/ eserver/support/xseries/ index.html
Ye s
Is the problem
solved?
View support telephone numbers at
http://www.ibm.com/planetwide/.
Hardware
No Software
Hardware or
software problem?
IBM System x3800 Ty pe 8866
Installation Guid e

Note: Before using this information and the product it supports, read the general information in “Notices” on page 65, and the
Warranty and Support Information document on the IBM System x Documentation CD.
4th Edition (November 2006)
© Copyright International Business Machines Corporation 2006. All rights reserved.
US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . .1
The IBM System x Documentation CD . . . . . . . . . . . . . . . . .2
Hardware and software requirements . . . . . . . . . . . . . . . .2
Using the Documentation Browser . . . . . . . . . . . . . . . . .2
Notices and statements in this document . . . . . . . . . . . . . . . .3
Features and specifications . . . . . . . . . . . . . . . . . . . . .4
Major components of the server . . . . . . . . . . . . . . . . . . .5
Chapter 2. Installing options . . . . . . . . . . . . . . . . . . . .7
Installation guidelines . . . . . . . . . . . . . . . . . . . . . . .7
System reliability guidelines . . . . . . . . . . . . . . . . . . . .8
Working inside the server with the power on . . . . . . . . . . . . .8
Handling static-sensitive devices . . . . . . . . . . . . . . . . . .9
Removing the front cover, top cover, and bezel . . . . . . . . . . . . .9
Removing the front cover (tower model only) . . . . . . . . . . . . .10
Removing the top cover . . . . . . . . . . . . . . . . . . . .10
Removing the bezel . . . . . . . . . . . . . . . . . . . . . .11
Installing a hot-swap hard disk drive . . . . . . . . . . . . . . . . .12
Installing additional DIMMs . . . . . . . . . . . . . . . . . . . .13
Installing a DIMM . . . . . . . . . . . . . . . . . . . . . . .14
Installing a memory card . . . . . . . . . . . . . . . . . . . .16
Installing an additional microprocessor . . . . . . . . . . . . . . . .17
Installing an adapter . . . . . . . . . . . . . . . . . . . . . . .21
Installing the Remote Supervisor Adapter II SlimLine . . . . . . . . . .21
Installing a ServeRAID-8i adapter . . . . . . . . . . . . . . . . .22
Installing a hot-plug adapter . . . . . . . . . . . . . . . . . . .23
Completing the installation . . . . . . . . . . . . . . . . . . . . .25
Installing the top cover, bezel and front cover . . . . . . . . . . . . .25
Connecting the cables . . . . . . . . . . . . . . . . . . . . .27
Updating the server configuration . . . . . . . . . . . . . . . . .27
Chapter 3. Server controls, connectors, LEDs, and power . . . . . . . .29
Front view . . . . . . . . . . . . . . . . . . . . . . . . . .29
Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Server power features . . . . . . . . . . . . . . . . . . . . . .33
Turning on the server . . . . . . . . . . . . . . . . . . . . .33
Turning off the server . . . . . . . . . . . . . . . . . . . . .33
Chapter 4. Configuring the server . . . . . . . . . . . . . . . . .35
Using the ServerGuide Setup and Installation CD . . . . . . . . . . . .35
Using the Configuration/Setup Utility program . . . . . . . . . . . . .35
Installing and using the baseboard management controller utility programs . . .36
Using the baseboard management controller utility programs . . . . . . .36
Using the SAS/SATA Configuration Utility program . . . . . . . . . . . .37
Using the ServeRAID configuration programs . . . . . . . . . . . . . .37
Using the PXE boot agent utility program . . . . . . . . . . . . . . .37
Using the Remote Supervisor II Web Interface . . . . . . . . . . . . .38
Chapter 5. Updating IBM Director . . . . . . . . . . . . . . . . .39
Chapter 6. Solving problems . . . . . . . . . . . . . . . . . . .41
© Copyright IBM Corp. 2006 iii
Diagnostic tools overview . . . . . . . . . . . . . . . . . . . . .41
POST beep codes . . . . . . . . . . . . . . . . . . . . . . .41
POST error codes . . . . . . . . . . . . . . . . . . . . . . . .42
Troubleshooting tables . . . . . . . . . . . . . . . . . . . . . .44
Light path diagnostics . . . . . . . . . . . . . . . . . . . . . .54
Remind button . . . . . . . . . . . . . . . . . . . . . . . .57
Light path diagnostics panel . . . . . . . . . . . . . . . . . . .57
Appendix. Getting help and technical assistance . . . . . . . . . . .63
Before you call . . . . . . . . . . . . . . . . . . . . . . . . .63
Using the documentation . . . . . . . . . . . . . . . . . . . . .63
Getting help and information from the World Wide Web . . . . . . . . . .64
Software service and support . . . . . . . . . . . . . . . . . . .64
Hardware service and support . . . . . . . . . . . . . . . . . . .64
IBM Taiwan product service . . . . . . . . . . . . . . . . . . . .64
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . .65
Important notes . . . . . . . . . . . . . . . . . . . . . . . . .66
Product recycling and disposal . . . . . . . . . . . . . . . . . . .67
Battery return program . . . . . . . . . . . . . . . . . . . . . .68
Electronic emission notices . . . . . . . . . . . . . . . . . . . .69
Federal Communications Commission (FCC) statement . . . . . . . . .69
Industry Canada Class A emission compliance statement . . . . . . . .69
Australia and New Zealand Class A statement . . . . . . . . . . . .69
United Kingdom telecommunications safety requirement . . . . . . . . .69
European Union EMC Directive conformance statement . . . . . . . . .70
Taiwanese Class A warning statement . . . . . . . . . . . . . . .70
Chinese Class A warning statement . . . . . . . . . . . . . . . .70
Japanese Voluntary Control Council for Interference (VCCI) statement . . .70
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
iv IBM System x3800 Type 8866: Installation Guide
Safety
Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt.
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Avant d’installer ce produit, lisez les consignes de sécurité.
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
© Copyright IBM Corp. 2006 v
Antes de instalar este producto, lea la información de seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
Important:
All caution and danger statements in this documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM Safety Information book.
For example, if a caution statement begins with a number 1, translations for that caution statement appear in the IBM Safety Information book under statement 1.
Be sure to read all caution and danger statements in this documentation before performing the instructions. Read any additional safety information that comes with the server or optional device before you install the device.
vi IBM System x3800 Type 8866: Installation Guide
Statement 1:
DANGER
Electrical
current from power, telephone, and communication cables is
hazardous.
To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
v Connect all power cords to a properly wired and grounded electrical
outlet.
v Connect to properly wired outlets any equipment that will be attached to
this product.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached devices.
To Connect: To Disconnect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
5. Turn device ON.
Safety vii
Statement 2:
CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water v Heat to more than 100°C (212°F) v Repair or disassemble
Dispose
Statement 3:
of the battery as required by local ordinances or regulations.
CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
v Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
laser products contain an embedded Class 3A or Class 3B laser
Some diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
viii IBM System x3800 Type 8866: Installation Guide
Statement 4:
18 kg (39.7 lb) 32 kg (70.5 lb) 55 kg (121.2 lb)
CAUTION: Use safe practices when lifting.
Statement 5:
CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2
1
Safety ix
Statement 8:
CAUTION: Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.
Statement 26:
CAUTION: Do not place any object on top of rack-mounted devices.
x IBM System x3800 Type 8866: Installation Guide
Chapter 1. Introduction
This Installation Guide contains instructions for setting up your IBM® System x3800 Type 8866 server and basic instructions for installing some options. More detailed instructions for installing options are in the User’s Guide on the IBM System x
Documentation CD, which comes with the server. This document contains
information about:
v Setting up and cabling the server
v Starting and configuring the server
v Installing some options
v Solving problems
firmware and documentation updates are available, you can download them from
If the IBM Web site. The server might have features that are not described in the documentation that comes with the server, and the documentation might be updated occasionally to include information about those features, or technical updates might be available to provide additional information that is not included in the server documentation. To check for updates, go to http://www.ibm.com/servers/eserver/ support/xseries/index.html, Go. For firmware updates, click the Download tab. For documentation updates, click the Install and use tab, and click Product documentation.
select System x3800 from the Hardware list, and click
Note: Changes are made periodically to the IBM Web site. Procedures for locating
firmware and documentation might vary slightly from what is described in this document.
The server comes with an IBM ServerGuide™ Setup and Installation CD to help you configure the hardware, install device drivers, and install the operating system.
The server comes with a limited warranty. Yo u can obtain up-to-date information about the server and other IBM server products at http://www.ibm.com/systems/x/.
Record information about the server in the following table. Yo u will need this information when you register the server with IBM.
Product name IBM System x3800 server Machine type 8866 Model number _____________________________________________ Serial number _____________________________________________
The model number and serial number are on the ID labels, one on the lower-right front of the bezel and the other at the rear of the right side, as shown in the following illustration.
© Copyright IBM Corp. 2006 1
ID labels
For a list of supported options for the server, see the ServerProven® Web site at http://www.ibm.com/servers/eserver/serverproven/compat/us/ .
The IBM System x Documentation CD
The IBM System x Documentation CD contains documentation for the server in Portable Document Format (PDF) and includes the IBM Documentation Browser to help you find information quickly.
Hardware and software requirements
The IBM System x Documentation CD requires the following minimum hardware and software:
v Microsoft® Windows® XP, Windows 2000, or Red Hat Linux.
v 100 MHz microprocessor.
v 32 MB of RAM.
v Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
systems.
Using the Documentation Browser
Use the Documentation Browser to browse the contents of the CD, read brief descriptions of the documents, and view documents using Adobe Acrobat Reader or xpdf. The Documentation Browser automatically detects the regional settings in use in your server and displays the documents in the language for that region (if available). If a document is not available in the language for that region, the English-language version is displayed.
Use one of the following procedures to start the Documentation Browser:
v If Autostart is enabled, insert the CD into the CD drive. The Documentation
Browser starts automatically.
2 IBM System x3800 Type 8866: Installation Guide
v If Autostart is disabled or is not enabled for all users, use one of the following
procedures:
If you are using a Windows operating system, insert the CD into the drive and
click Start --> Run. In the Open field, type
e:\win32.bat
where e is the drive letter of the drive, and click OK.
If you are using Red Hat Linux, insert the CD into the drive; then, run the
following command from the /mnt/cdrom directory:
sh runlinux.sh
Select the server from the Product menu. The Available Topics list displays all the documents for the server. Some documents might be in folders. A plus sign (+) indicates each folder or document that has additional documents under it. Click the plus sign to display the additional documents.
When you select a document, a description of the document appears under Topic Description. To select more than one document, press and hold the Ctrl key while you select the documents. Click View Book to view the selected document or documents in Acrobat Reader or xpdf. If you selected more than one document, all the selected documents are opened in Acrobat Reader or xpdf.
To search all the documents, type a word or word string in the Search field and click Search. The documents in which the word or word string appears are listed in order of the most occurrences. Click a document to view it, and press Crtl+F to use the Acrobat search function or Alt+F to use the xpdf search function within the document.
Click Help for detailed information about using the Documentation Browser.
Notices and statements in this document
The caution and danger statements that appear in this document are also in the multilingual Safety Information document, which is on the IBM System x
Documentation CD. Each statement is numbered for reference to the corresponding
statement in the Safety Information document.
The following notices and statements are used in this document:
v Note: These notices provide important tips, guidance, or advice. v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
Chapter 1. Introduction 3
Features and specifications
The following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply.
Table 1. Features and specifications
Microprocessor:
v Intel® Xeon
v 1 MB Level-2 cache v 667 MHz front-side bus (FSB) v Support for up to four microprocessors
Use the Configuration/Setup Utility
Note:
program to determine the type and speed of the microprocessors.
Memory:
v Minimum: 1 GB depending on server
model, expandable to 64 GB
v Type: 333 MHz, registered, ECC,
PC2-3200 double data rate (DDR) II, SDRAM
v Sizes: 512 MB (some models only), 1
GB, 2 GB or 4 GB in pairs
v Connectors: Two-way interleaved, four
dual inline memory module (DIMM) connectors per memory card
v Maximum: Four memory cards, each
card containing two pairs of PC2-3200 DDRII DIMMs
Drives:
v CD: IDE v Diskette: 1.44 MB v Serial Attached SCSI (SAS) hard disk
drive
Expansion
bays:
v Twelve SAS, 3.5-inch bays v Three 5.25-inch bays (CD-ROM
installed)
v One 3.5-inch bay (diskette drive
installed)
Expansion
slots:
v Four PCI Express x8 hot-plug slots v Two PCI-X 2.0 hot-plug 266 MHz/64-bit
slots
Upgradeable
microcode:
System BIOS, diagnostics, service processor, BMC, and SAS microcode
Upgradeable to three power supplies:
v Standard: Two 775 watt 11 0 V or 220 V
ac input dual-rated power supplies
v Upgradeable to three power supplies
Size:
v 7 U v Height: 311 mm (12.3 in.) v Depth: 715 mm (28.15 in.) v Width: 440 mm (17.32 in.) v Weight: approximately 55 kg (121.2 lb)
when fully configured or 47 kg (104 lb) minimum
Racks of 4.45 cm (1.75 inches). Each increment is referred to as a unit, or “U.” A 1-U-high device is 4.45 cm (1.75 inches) tall.
Integrated functions:
v Baseboard management controller v IBM EXA-32 Chipset with integrated
memory and I/O controller
v Service processor support for Remote
Supervisor Adapter II SlimLine
v Light path diagnostics v Three Universal Serial Bus (USB) ports
(2.0) Two on rear of server One on front of server
v Broadcom 5704C dual 10/100/1000
Gigabit Ethernet controllers
v AT I 7000-M video
16 MB video memory SVGA compatible
Mouse connector
v v Keyboard connector v Serial connector
Acoustical noise emissions:
v Sound power, idle: 6.6 bel declared v Sound power, operating: 6.6 bel
declared
Environment:
v Air temperature:
Server on: 10° to 35°C (50.0° to
Server off: 10° to 43°C (50.0° to
Humidity:
v
Server on: 8% to 80% Server off: 8% to 80%
are marked in vertical increments
95.0°F); altitude: 0 to 2133 m (6998.0 ft)
109.4°F); maximum altitude: 2133 m (6998.0 ft)
Heat output:
Approximate heat output in British thermal units (Btu) per hour:
v Minimum configuration: 2006 Btu (588
watts) per hour
v Maximum configuration: 6346 Btu (1860
watts) per hour
Electrical
input:
v Sine-wave input (50-60 Hz) required v Input voltage low range:
Minimum: 100 V ac Maximum: 127 V ac
Input voltage high range:
v
Minimum: 200 V ac Maximum: 240 V ac
v Approximate input kilovolt-amperes (kVA):
Minimum: 0.60 kVA Maximum: 1.9 kVA
Notes:
1. Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
2. These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO
9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.
4 IBM System x3800 Type 8866: Installation Guide
Major components of the server
Blue on a component indicates touch points, where you can grip the component to remove it from or install it in the server, open or close a latch, and so on.
Orange on a component or an orange label on or near a component indicates that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component.
The following illustration shows the major components in the server.
Top cover
PCI divider
I/O board
DIMM
Hard disk drive filler panel
Hot-swap hard disk drive
Air baffle
Microprocessor baffle
Heat sink
Microprocessor
Memory card
Hot-swap fans 80 mm
FRONT
Hot-swap fans 92 mm
VRM
Microprocessor tray
Operator information panel
Diskette drive
CD drive
Power supply filler
Hot-swap power supply
PCI slots
Rack bezel Front cover
Chapter 1. Introduction 5
6 IBM System x3800 Type 8866: Installation Guide
Chapter 2. Installing options
This chapter provides basic instructions for installing hardware options in the server. These instructions are intended for users who are experienced with setting up IBM server hardware. If you need more detailed instructions, see the User’s Guide on the IBM System x Documentation CD.
Installation guidelines
Before you begin installing options, read the following information:
v Read the safety information that begins on page v, the guidelines in “Working
inside the server with the power on” on page 8, and “Handling static-sensitive devices” on page 9. This information will help you work safely.
v When you install your new server, take the opportunity to download and apply
the most recent firmware updates. This step will help to ensure that any known issues are addressed and that your server is ready to function at maximum levels of performance. To download firmware updates for your server, go to http://www.ibm.com/servers/eserver/support/xseries/index.html, select System x3800 from the Hardware list, click Go, and then click the Download tab. For additional information about tools for updating, managing, and deploying firmware, see the System x and xSeries® Tools Center at http:// publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
v Before you install optional hardware devices, make sure that the server is
working correctly. Start the server, and make sure that the operating system starts, if an operating system is installed, or that a 19990305 error code is displayed, indicating that an operating system was not found but the server is otherwise working correctly. If the server is not working correctly, see Chapter 6, “Solving problems,” on page 41 for diagnostic information.
v Observe good housekeeping in the area where you are working. Place removed
covers and other parts in a safe place.
v If you must start the server while the cover is removed, make sure that no one is
near the server and that no tools or other objects have been left inside the server.
v Do not attempt to lift an object that you think is too heavy for you. If you have to
lift a heavy object, observe the following precautions:
Make sure that you can stand safely without slipping.
Distribute the weight of the object equally between your feet.
Use a slow lifting force. Never move suddenly or twist when you lift a heavy
object.
To avoid straining the muscles in your back, lift by standing or by pushing up
with your leg muscles.
Make sure that you have an adequate number of properly grounded electrical
v
outlets for the server, monitor, and other devices.
v Back up all important data before you make changes to disk drives.
v Have a small flat-blade screwdriver available.
v Yo u do not have to turn off the server to install or replace hot-swap power
supplies, hot-swap fans, hot-plug adapters, or hot-plug Universal Serial Bus (USB) devices. However, you must turn off the server before you perform any steps that involve removing or installing adapter cables.
v Blue on a component indicates touch points, where you can grip the component
to remove it from or install it in the server, open or close a latch, and so on.
© Copyright IBM Corp. 2006 7
v Orange on a component or an orange label on or near a component indicates
that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component.
v When you are finished working on the server, reinstall all safety shields, guards,
labels, and ground wires.
v For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
System reliability guidelines
To help ensure proper cooling and system reliability, make sure that the following requirements are met:
v Each of the drive bays has a drive or a filler panel installed in it.
v If the server has redundant power, at least three of the power-supply bays have
a power supply installed.
v There is adequate space around the server to allow the server cooling system to
work properly. Leave approximately 50 mm (2 in.) of open space around the front and rear of the server. Do not place objects in front of the fans. For proper cooling and airflow, replace the server cover before turning on the server. Operating the server for extended periods of time (more than 30 minutes) with the server cover removed might damage server components.
v Yo u have followed the cabling instructions that come with optional adapters.
v Yo u have replaced a failed fan within 48 hours.
v Yo u have replaced a hot-swap drive within 2 minutes of removal.
v Yo u do not operate the server without the air baffle installed. Operating the
server without the air baffle might cause the microprocessor or microprocessors to overheat.
v Microprocessor sockets 2, 3, and 4 each always contain either a microprocessor
baffle or a microprocessor and heat sink.
v For redundant and hot-swappable operation, the power supplies are connected to
200-240 V ac.
Working inside the server with the power on
Attention: Static electricity that is released to internal server components when
the server is powered-on might cause the server to halt, which could result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on.
The server supports hot-swap devices and is designed to operate safely while it is turned on and the cover is removed. Follow these guidelines when you work inside a server that is turned on:
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts
before working inside the server; do not wear cuff links while you are working inside the server.
v Do not allow your necktie or scarf to hang inside the server.
v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist
watches.
8 IBM System x3800 Type 8866: Installation Guide
v Remove items from your shirt pocket, such as pens and pencils, that could fall
into the server as you lean over it.
v Avoid dropping any metallic objects, such as paper clips, hairpins, and screws,
into the server.
Handling static-sensitive devices
Attention: Static electricity can damage the server and other electronic devices.
To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them.
To reduce the possibility of damage from electrostatic discharge, observe the following precautions:
v Limit your movement. Movement can cause static electricity to build up around
you.
v The use of a grounding system is recommended. For example, wear an
electrostatic-discharge wrist strap, if one is available. Always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on.
v Handle the device carefully, holding it by its edges or its frame.
v Do not touch solder joints, pins, or exposed circuitry.
v Do not leave the device where others can handle and damage it.
v While the device is still in its static-protective package, touch it to an unpainted
metal part on the outside of the server for at least 2 seconds. This drains static electricity from the package and from your body.
v Remove the device from its package and install it directly into the server without
setting down the device. If it is necessary to set down the device, put it back into its static-protective package. Do not place the device on the server cover or on a metal surface.
v Take additional care when handling devices during cold weather. Heating reduces
indoor humidity and increases static electricity.
Removing the front cover, top cover, and bezel
Remove the top cover and bezel to access the inside of the server. On a tower model, you must also unlock or remove the front cover.
Chapter 2. Installing options 9
Removing the front cover (tower model only)
To remove the front cover, complete the following steps.
Unlock
Lock
1. Read the safety information that begins on page v and “Installation guidelines” on page 7.
2. If you are installing or replacing a non-hot-swap component, turn off the server and all peripheral devices. Disconnect all power cords; then, disconnect all external cables from the server.
3. Unlock the front cover; then, grasp the top corners of the front cover and pull it away from the server.
4. Lift the front cover to release the two tabs at the bottom edge of the cover.
5. Store the front cover in a safe place.
Removing the top cover
On a tower model, make sure that you unlock or remove the front cover before you remove the top cover.
To remove the top cover, complete the following steps.
10 IBM System x3800 Type 8866: Installation Guide
Top cover
Cover release latch
1. Read the safety information that begins on page v and “Installation guidelines” on page 7.
2. If you are installing or replacing a non-hot-swap component, turn off the server and all peripheral devices. Disconnect all power cords; then, disconnect all external cables from the server.
3. Lift the plastic cover-release latch near the edge of the top cover.
4. Slide the top cover slightly toward the rear of the server; the cover will stop after moving approximately 25 mm (1 inch). Lift the cover off the server, and set the cover aside.
Attention: For proper cooling and airflow, replace the top cover before turning
on the server. Operating the server for more than 2 minutes with the top cover removed might damage server components.
Removing the bezel
On a tower model, make sure that you unlock or remove the front cover before you remove the top cover and bezel.
To remove the bezel, complete the following steps:
Chapter 2. Installing options 11
Bezel
1. Press on the two release latches at the top edge of the bezel, and pull the top of the bezel slightly away from the server.
2. Lift the bezel to release the two tabs at the bottom edge of the bezel.
3. Store the bezel in a safe place.
Installing a hot-swap hard disk drive
The following illustration shows how to install a hot-swap hard disk drive.
Filler panel
Hard disk drive assembly
Drive handle (open position)
5.25-inch bays for
The server supports up to two 5.25-inch, half-high, SCSI tape drives in the
5.25-inch bays. A SCSI adapter is required to support the tape drives.
Attention: Static electricity that is released to internal server components when
the server is powered-on might cause the server to halt, which could result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on.
supported tape drives
Complete the following steps to install a hot-swap hard disk drive:
12 IBM System x3800 Type 8866: Installation Guide
1. Read the safety information that begins on page v and “Installation guidelines” on page 7.
2. If you are installing drives in a tower model, remove the front cover (see “Removing the front cover (tower model only)” on page 10).
3. Remove the filler panel from one of the empty hot-swap bays.
4. Make sure that the tray handle is open; then, install the hard disk drive into the hot-swap bay.
Notes:
1. When you turn on the server, check the hard disk drive status LEDs to make sure that the hard disk drive is operating correctly.
If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and must be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
2. If the server will be configured for RAID operation using an optional ServeRAID controller, you must configure the disk arrays before installing the operating system. See the ServeRAID™ documentation on the IBM ServeRAID Support CD for additional information about RAID operation and complete instructions for using ServeRAID Manager.
you have other options to install or remove, do so now; otherwise, go to
If “Completing the installation” on page 25.
Installing additional DIMMs
The following illustration shows how to install a dual inline memory module (DIMM) on a memory card.
The following notes describe information that you must consider when installing DIMMs:
v Yo u can configure your server to use memory mirroring and memory scrubbing.
For detailed information about configuring your server and using these features, see the User’s Guide on the IBM System x Documentation CD.
v To use the hot-add and hot-swap memory features, you must reconfigure your
server using the Configuration/Setup Utility program. See the User’s Guide on the IBM System x Documentation CD for additional information.
v DIMMs can be hot-added to the server once without having to reconfigure the
server. If you hot-add additional DIMMs to the server, you must reconfigure your server using the Configuration/Setup Utility program.
Chapter 2. Installing options 13
v There must be at least one memory card with one pair of DIMMs installed for the
server to operate.
v When you install additional DIMMs on a memory card, be sure to install them in
pairs. All the DIMM pairs on each memory card must be of the same size and type.
v Add odd-numbered DIMMs to each available memory card first, and then add the
even-numbered pairs.
v Install the DIMMs on each memory card in the order shown in the following table.
Each memory card must have at least one pair of DIMMs. See the User’s Guide on the IBM System x Documentation CD for additional memory configuration installation sequences.
Table 2. Memory card installation sequence
Installation order Memory card DIMM pair
First 1 1 and 3
2 and 4
Second 2 1 and 3
2 and 4
Third 3 1 and 3
2 and 4
Fourth 4 1 and 3
2 and 4
v If memory mirroring is enabled, you can hot-replace one memory card at a time
on each memory power bus.
If a problem with a DIMM is detected, light path diagnostics will light the system-error LED on the front of the server, indicating that there is a problem and guide you to the defective DIMM. When this occurs, first identify the defective DIMM; then, remove and replace the DIMM.
The following illustration shows the LEDs on the memory card.
Memory Hot-Swap Enabled LED: When this LED is lit, it indicates that
hot-swap memory is enabled.
Error LED: When this LED is lit, it indicates that a DIMM or memory card has
failed.
Memory Port Power LED: When this LED is off, it indicates that power is
removed from the port and that you can remove the memory card to replace a failed memory card or DIMM.
Installing a DIMM
Complete the following steps to install additional DIMMs:
14 IBM System x3800 Type 8866: Installation Guide
Memory Port Power
Error
Memory Hot-Swap Enabled
1. Read the safety information that begins on page v and “Installation guidelines” on page 7.
2. Remove the front cover (tower model only), and the top cover (see “Removing the front cover, top cover, and bezel” on page 9).
3. If you are not hot-swapping a DIMM, turn off the server and peripheral devices, and disconnect the power cords and all external cables necessary to replace the device.
Attention: When moving the memory card, do not allow it to touch any
components or structures inside the server.
If you are hot-swapping a DIMM, make sure that the Memory Hot-Swap Enabled LED is lit.
Memory card retention levers
4. Remove the memory card:
a. Open the memory card retention levers on the top of the memory card.
b. While holding the retention levers open, lift the memory card out of the
server.
5. Place the memory card on a flat, static-protective surface with the DIMM
connectors facing up.
Attention: To avoid breaking the DIMM retaining clips or damaging the
DIMM connectors, open and close the clips gently.
6. Open the retaining clip on each end of the DIMM connector.
7. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the server. Then, remove the DIMM from the package.
8. Turn the DIMM so that the DIMM keys align correctly with the slot.
Chapter 2. Installing options 15
DIMM
Retaining clip
9. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is seated in the connector. If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly inserted; open the retaining clips, remove the DIMM, and then reinsert it.
10. Repeat steps 6 on page 15 through 9 to install the second DIMM of the pair; then, continue with “Installing a memory card” for instructions on how to install a memory card.
Installing a memory card
The server supports up to four memory cards. Each memory card must have at least one pair of DIMMs. Yo u can hot-add one memory card to each of the memory power buses, provided your operating system supports that function.
At least one memory card with one pair of DIMMs must be installed in the server to operate correctly.
To install a memory card, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines”
on page 7.
2. Remove the front cover (tower model only), and the top cover (see “Removing
the front cover, top cover, and bezel” on page 9).
3. Make sure that the locking levers on the edge of the memory card are fully
open, and insert the memory card into an open memory-card connector on the microprocessor board.
4. Press the memory card into the connector.
5. Close the small locking lever; then, close the large locking lever.
you have other options to install or remove, do so now; otherwise, go to
If “Completing the installation” on page 25.
16 IBM System x3800 Type 8866: Installation Guide
Installing an additional microprocessor
The following notes describe information that you must consider when installing a microprocessor:
v The voltage regulator modules (VRMs) for microprocessors 1 and 2 are
integrated on the microprocessor board; the VRMs for microprocessors 3 and 4 come with the microprocessor options and must be installed on the microprocessor board.
v Each microprocessor socket must be populated with either a microprocessor
baffle or a heat sink and microprocessor to ensure the server operates properly.
v All microprocessors must be the same cache size and type, and the same clock
speed.
v Install the microprocessors in the order shown in the following illustration.
1234
To install an additional microprocessor, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines” on page 7.
2. Turn off the server and peripheral devices, and disconnect the power cords and any USB cable that might be connected to the USB port on the front of the server. Remove the server cover and bezel.
Attention: When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 9.
3. Remove the front cover (tower model only), bezel, and the top cover (see “Removing the front cover, top cover, and bezel” on page 9).
Chapter 2. Installing options 17
4. Remove all fans from the server.
5. Remove all memory cards from the server.
6. Remove the bezel (see “Removing the bezel” on page 11).
7. Remove the microprocessor tray:
a. Open the microprocessor-tray release latch.
Air baffle
Microprocessor-tray lever
Microprocessor-tray release latch
Microprocessor-tray retention latch (both sides of tray)
Microprocessor-tray lever
b. Open the microprocessor-tray levers.
18 IBM System x3800 Type 8866: Installation Guide
c. Pull out the microprocessor tray until it stops and then reposition your
hands to grasp the body of the tray.
d. Press in on the release latches on each side of the tray; then, pull the tray
out the rest of the way.
8. Lift the air baffle out of the microprocessor tray.
Air baffle
Heat sink
Microprocessor
FRONT
Microprocessor baffle
FRONT
FRONT
FRONT
9. Remove the microprocessor baffle from a microprocessor socket and store it
VRM 4
for future use. If you remove a microprocessor you must install a microprocessor baffle to prevent the server from overheating.
Microprocessor baffle
Heat sink retention clip
10. Open the heat-sink retention clip:
a. Press down on one side of the heat-sink retention clip to release it from the
b. Rotate the heat-sink retention clip forward to its fully open position.
side of the socket; then, repeat the process on the opposite side.
Chapter 2. Installing options 19
11. Remove the protective cover, tape, or label from the surface of the microprocessor socket, if any is present.
12. Lift the microprocessor-release lever to the fully-open position (approximately
135° angle).
Lever fully
Lever closed
open
13. Touch the static-protective package that contains the new microprocessor to
any unpainted metal surface on the server; then, remove the microprocessor from the package.
Attention: To avoid bending the pins on the microprocessor, do not use
excessive force when pressing it into the socket.
14. Position the microprocessor over the microprocessor socket as shown in the
following illustration. Carefully press the microprocessor into the socket.
Microprocessor
Microprocessor orientation indicator
Microprocessor connector
Microprocessor­release lever
15. Close the microprocessor-release lever to secure the microprocessor.
16. Remove the heat sink from its package and remove the cover from the bottom
of the heat sink.
17. Position the heat sink above the microprocessor; then, press the heat sink into
place and close the heat-sink release lever.
Note: If you are installing an additional microprocessor in microprocessor
socket 3 or 4, a VRM must also be installed.
18. If necessary, install a VRM in the correct connector.
19. Reinstall the microprocessor tray in the server:
a. Place the air baffle over the heat sinks and microprocessor baffles.
Note: Make sure that the air baffle lies flat and within the grooves on top
of the microprocessor heat sinks and microprocessor baffles and that the
20 IBM System x3800 Type 8866: Installation Guide
air baffle remains in place while you close the microprocessor tray. You might find it helpful to hold the air baffle in place with your thumbs while closing the microprocessor tray.
b. Make sure that the microprocessor-tray release latch is open; then, push
the microprocessor tray into the server.
c. Close the tray levers and make sure they are securely latched.
d. Close the microprocessor-tray release latch.
e. Reinstall the fans and memory cards in the server.
you have other options to install or remove, do so now; otherwise, go to
If “Completing the installation” on page 25.
Installing an adapter
The following sections describe how to install adapters in the server.
Installing the Remote Supervisor Adapter II SlimLine
An optional IBM Remote Supervisor Adapter II SlimLine can be installed only in its dedicated connector on the I/O board. The following illustration shows how to install a Remote Supervisor Adapter II SlimLine.
Front standoff
I/O board
Remote Supervisor Adapter II SlimLine connector
Rear standoff
Remote Supervisor Adapter II SlimLine
Complete the following steps to install a Remote Supervisor Adapter II SlimLine:
1. Read the safety information that begins on page v and “Installation guidelines” on page 7.
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables necessary to remove the I/O board.
Attention: When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 9.
3. Unlock the front cover (tower model only), and remove the top cover (see “Removing the front cover, top cover, and bezel” on page 9).
Chapter 2. Installing options 21
4. Note the location of the internal cables connected to the I/O board; then,
AC
DC
remove the cables from the I/O board and move them out of the way.
5. Remove the I/O board from the server and place the I/O board on a flat, static-protective surface with the connectors facing up.
6. Insert the front of the adapter into the front standoff; then, rotate the rear of the adapter into the rear standoff.
7. Press the Remote Supervisor Adapter II SlimLine firmly into the connector.
8. Reinstall the I/O board in the server and reconnect the internal cables to the I/O board.
Installing a ServeRAID-8i adapter
If you are installing an optional ServeRAID-8i adapter, review the following information:
v A ServeRAID-8i adapter can be installed only in the dedicated slot on the PCI
board.
v The ServeRAID-8i adapter is not cabled to the server, and no rerouting of the
SAS cables is required.
following illustration shows how to install a ServeRAID-8i adapter.
The
ServeRAID-8i adapter
ServeRAID-8i slot
For more detailed instructions or information, see the User’s Guide on the IBM
System x Documentation CD.
22 IBM System x3800 Type 8866: Installation Guide
Installing a hot-plug adapter
Attention: Static electricity that is released to internal server components when
the server is powered-on might cause the server to halt, which could result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on.
The PCI bus configuration is as follows:
v Hot-plug, full-length PCI-X 2.0 266 MHz/64-bit slot 1 and slot 2. v Hot-plug, full-length PCI Express x8 (x8 lanes) slot 3 through slot 6.
install a hot-plug PCI adapter, complete the following steps.
To
Notes:
1. For hot-pluggable adapters, make sure that the PCI hot-plug device driver is installed. For details, see the documentation that comes with the adapter. For more detailed instructions and information about installing PCI adapters, see the section about installing options in the User’s Guide on the IBM System x
Documentation CD.
2. The supported versions of Red Hat® Enterprise Linux®, SUSE Linux Enterprise Server, and NetWare do not support the use of the hot-plug feature with the PCI Express slots. Install the necessary operating system updates from the vendor, when available.
Read the safety information that begins on page v and “Installation guidelines”
1. on page 7.
2. Unlock the front cover (tower model only), and remove the top cover (see “Removing the front cover, top cover, and bezel” on page 9).
3. Determine which PCI expansion slot you will use for the adapter.
Chapter 2. Installing options 23
PCI retaining bar
PCI divider
Attention LED (yellow)
Powe r LED (green)
Ta b
Adapter­retention latch
4. See the documentation that comes with the adapter for instructions for setting jumpers or switches and for cabling.
Note: Route adapter cables before you install the adapter.
5. Install the adapter:
a. Open the blue adapter guide by lifting the front edge.
b. Push the orange adapter retention latch toward the rear of the server and
open the tab. The power LED for the slot turns off if an adapter is installed in the slot.
c. Remove the expansion-slot cover.
d. Carefully grasp the adapter by its top edge or upper corners, and align it
with the connector on the PCI board.
e. If necessary, remove the adapter guide before installing a full-length adapter.
f. Press the adapter firmly into the adapter connector.
g. Push down on the blue PCI retaining bar to stabilize the adapter.
h. Close the tab; then, push down on the orange adapter retention latch until it
clicks into place, securing the adapter.
6. Connect any required cables to the adapter.
If you have other options to install or remove, do so now; otherwise, go to “Completing the installation” on page 25.
24 IBM System x3800 Type 8866: Installation Guide
Completing the installation
To complete the installation, complete the following steps:
1. Make sure all internal cables are properly routed through the server and that all cable retention devices are in place. If you have installed an optional SAS backplane, be sure that the SAS signal cables have been routed through the internal cable management arm.
2. Install the top cover, bezel, and front cover (tower model only). See “Installing the top cover, bezel and front cover” for more information.
3. Connect the cables and power cords. See “Connecting the cables” on page 27 for more information.
4. Install the server in a rack (rack model only). See the Rack Installation
Instructions that come with the server for complete rack installation and removal
instructions.
5. Put the server in position and lock the casters (tower model only).
Installing the top cover, bezel and front cover
Installing the top cover
To install the server top cover, complete the following steps:
1. Make sure that all cables, adapters, and other components are installed and seated correctly and that you have not left loose tools or parts inside the server.
Top cover
2. Move the cover-release latch to the open (up) position.
3. Insert the bottom tabs of the cover into the matching slots in the server chassis.
4. Close the cover-release latch to pull the cover forward and lock the cover in place.
Cover release latch
Chapter 2. Installing options 25
Installing the bezel
To install the bezel, complete the following steps.
1. Insert the two tabs on the bottom of the bezel into the matching holes on the server chassis.
2. Push the top of the bezel toward the server until the locking tabs at the top of the bezel snap into place.
Installing the front cover
To install the front cover (tower model), complete the following steps.
Unlock
Lock
1. Insert the two tabs on the bottom of the front cover into the matching holes on the bezel.
26 IBM System x3800 Type 8866: Installation Guide
2. Push the top of the front cover toward the server until the two release latches at the top of the bezel snap into place.
3. Lock the tower front cover.
Connecting the cables
You must turn off the server (see Turning off the server) before connecting any cables to or disconnecting any cables from the server.
See the documentation that comes with optional devices for additional cabling instructions. It might be easier for you to route cables before you install certain options.
Cable identifiers are printed on the cables that come with the server and options. Use these identifiers to connect the cables to the correct connectors.
For details about the location and function of the input and output connectors, see Chapter 3, “Server controls, connectors, LEDs, and power,” on page 29.
The following illustration shows the location of the input and output connectors on the rear of the server.
Power-supply
SP Ethernet 10/100
USB 1
Video
USB 2
System serial
SP serial
Gigabit Ethernet 1
Updating the server configuration
When you start the server for the first time after you add or remove an internal option or external SAS or SCSI device, you might receive a message that the configuration has changed. The Configuration/Setup Utility program starts automatically so that you can save the new configuration settings. For more information, see the section about configuring the server in the User’s Guide on the IBM System x Documentation CD.
Mouse
Keyboard
IXA RS485
Gigabit Ethernet 2
Chapter 2. Installing options 27
Some options have device drivers that you must install. See the documentation that comes with each option for information about installing device drivers.
If more than one microprocessor is installed, the server can operate as a symmetric multiprocessing (SMP) server. You might have to upgrade the operating system to support SMP. For more information, see the section about using the ServerGuide
Setup and Installation CD in the User’s Guide on the IBM System x Documentation
CD and the operating-system documentation.
If the server has an optional RAID adapter and you have installed or removed a hard disk drive, see the documentation that comes with the RAID adapter for information about reconfiguring the disk arrays.
For information about configuring the integrated Gigabit Ethernet controller, see the
User’s Guide on the IBM System x Documentation CD.
28 IBM System x3800 Type 8866: Installation Guide
Chapter 3. Server controls, connectors, LEDs, and power
This chapter describes the controls, connectors, and light-emitting diodes (LEDs) and how to turn the server on and off.
Front view
The following illustration shows the controls, LEDs, and connectors on the front of the server.
Operator information panel
Hard disk drive activity LED
Hard disk drive status LED
Diskette drive activity LED
Diskette-eject button
CD-eject button
CD drive activity LED
Operator information panel: The following illustration shows the controls and
LEDs on the operator information panel.
Power-control button
USB connector
Power-on LED
Hard disk drive activity LED
Locator LED
Information LED
Release latch
System-error LED
The following controls, connectors, and LEDs are on the operator information panel:
v USB connector: Connect a USB device to this connector. v Power-control button: Press this button to turn the server on and off manually.
A power-control-button shield comes with the server.
© Copyright IBM Corp. 2006 29
v Information LED: When the information LED on the operator information panel
is lit, it indicates that there is a suboptimal condition in the server and that light path diagnostics will light an additional LED to help isolate the condition. If the LOG LED on the light path diagnostics panel is lit, information about the condition is available in the baseboard management controller (BMC) log or in the system-event log. The condition might be that the BMC log is full or almost full.
This LED and LEDs on the light path diagnostics panel remain lit until you resolve the condition. If the only condition is that the BMC log is full or almost full, clear the BMC log or the system-event log through the Configuration/Setup Utility program to turn off the lit LEDs.
Important: Clear the BMC log and system-event log after you resolve all
conditions. If all conditions are resolved, this will turn off the information LED and LOG LED.
v Release latch: Slide this latch to the left to access the light path diagnostics
panel.
v System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the error.
v Locator LED: When this LED is lit, it has been lit remotely by the system
administrator to aid in visually locating the server.
v Hard disk drive activity LED: When this LED is flashing, it indicates that a SAS
hard disk drive is in use.
v Power-on LED: When this LED is lit and not flashing, it indicates that the server
is turned on. When this LED is flashing, it indicates that the server is turned off and still connected to an ac power source. When this LED is off, it indicates that ac power is not present, or the power supply or the LED itself has failed.
Note: If this LED is off, it does not mean that there is no electrical power in the
server. The LED might be burned out. To remove all electrical power from the server, you must disconnect the power cords from the electrical outlets.
disk drive activity LED: On some server models, each hot-swap hard disk
Hard
drive has an activity LED. When this LED is flashing, it indicates that the drive is in use.
Hard disk drive status LED: If a ServeRAID-8i adapter is installed, when this LED
is lit, it indicates that the associated hard disk drive has failed. If the LED flashes slowly (one flash per second), the drive is being rebuilt. If the LED flashes rapidly (three flashes per second), the controller is identifying the drive.
Diskette drive activity LED: When this LED is lit, it indicates that the diskette drive
is in use.
Diskette-eject button: Press this button to release a diskette from the diskette
drive.
CD drive activity LED: When this LED is lit, it indicates that the CD drive is in use.
CD-eject button: Press this button to release a CD or DVD from the DVD drive.
30 IBM System x3800 Type 8866: Installation Guide
Rear view
The following illustration shows the connectors and LEDs on the rear of the server.
AC power LED
DC power LED
Power-supply
SP Ethernet 10/100
USB 1
Video
SP Ethernet 10/100 activity LED
SP Ethernet 10/100 link LED
USB 2
System serial
SP serial
Fan error LED
Gigabit Ethernet 1 link LED
Gigabit Ethernet 1
Gigabit Ethernet 1 activity LED
Gigabit Ethernet 2 link LED
Gigabit Ethernet 2
I/O board error LED
Gigabit Ethernet 2 activity LED
Mouse
Keyboard
Remote Supervisor Adapter II SlimLine error LED
IXA RS485
Power-supply connector: Connect the power cord to this connector.
Video connector: Connect a monitor to this connector.
USB 1 connector: Connect a USB device to this connector.
SP Ethernet 10/100 connector: Use this connector to connect the service
processor to a network.
SP Ethernet 10/100 activity LED: This LED is on the SP Ethernet 10/100
connector. When this LED is lit, it indicates that there is activity between the server and the network.
SP Ethernet 10/100 link LED: This LED is on the SP Ethernet 10/100 connector.
When this LED is lit, it indicates that there is an active connection on the Ethernet port.
USB 2 connector: Connect a USB device to this connector.
Chapter 3. Server controls, connectors, LEDs, and power 31
System serial connector: Connect a 9-pin serial device to this connector.
SP Serial connector: Connect a 9-pin serial device to this connector.
Fan error LED: This LED is on the power supply filler. When this LED is lit, it
indicated that the fan has failed.
Mouse connector: Connect a mouse or other device to this connector.
Keyboard connector: Connect a keyboard to this connector.
Remote Supervisor Adapter II SlimLine error LED: This LED is on the I/O board
and is visible on the rear of the server. When this LED is lit, it indicates that there is a problem with the IBM Remote Supervisor Adapter II SlimLine.
IXA RS485 connector: Use this connector to connect to an iSeries server when
an Integrated xSeries Adapter (IXA) is installed.
I/O board error LED: This LED is on the I/O board and is visible on the rear of the
server. When this LED is lit, it indicates that there is a problem with the I/O board.
Gigabit Ethernet 2 activity LED: This LED is on the Gigabit Ethernet 2 connector.
When this LED flashes, it indicates that there is activity between the server and the network.
Gigabit Ethernet 2 connector: Use this connector to connect the server to a
network.
Gigabit Ethernet 2 link LED: This LED is on the Gigabit Ethernet 2 connector.
When this LED is lit, it indicates that there is an active connection on the Ethernet port.
Gigabit Ethernet 1 activity LED: This LED is on the Gigabit Ethernet 1 connector.
When this LED flashes, it indicates that there is activity between the server and the network.
Gigabit Ethernet 1 connector: Use this connector to connect the server to a
network.
Gigabit Ethernet 1 link LED: This LED is on the Gigabit Ethernet 1 connector.
When this LED is lit, it indicates that there is an active connection on the Ethernet port.
AC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Problem Determination and Service Guide on the IBM System x Documentation CD.
DC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Problem Determination and Service Guide on the IBM System x Documentation CD.
32 IBM System x3800 Type 8866: Installation Guide
Server power features
When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic except for the service processor is shut down; however, the server can respond to requests from the service processor, such as a remote request to turn on the server. The power-on LED flashes to indicate that the server is connected to ac power but is not turned on.
Turning on the server
Approximately 20 seconds after the server is connected to ac power, the power-control button becomes active, and one or more fans might start running to provide cooling while the server is connected to power. You can turn on the server and start the operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
v If a power failure occurs while the server is turned on, the server will restart
automatically when power is restored.
v If your operating system supports the systems-management software for an
optional Remote Supervisor Adapter II SlimLine, the systems-management software can turn on the server.
v If your operating system supports the Wake on LAN® feature, the Wake on LAN
feature can turn on the server.
Turning off the server
When you turn off the server and leave it connected to ac power, the server can respond to requests from the service processor, such as a remote request to turn on the server. While the server remains connected to ac power, one or more fans might continue to run. To remove all power from the server, you must disconnect it from the power source.
Some operating systems require an orderly shutdown before you turn off the server. See your operating-system documentation for information about shutting down the operating system.
Statement 5:
CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2
1
The server can be turned off in any of the following ways:
Chapter 3. Server controls, connectors, LEDs, and power 33
v Yo u can turn off the server from the operating system, if your operating system
supports this feature. After an orderly shutdown of the operating system, the server will be turned off automatically.
v Yo u can press the power-control button to start an orderly shutdown of the
operating system and turn off the server, if your operating system supports this feature.
v If the operating system stops functioning, you can press and hold the
power-control button for more than 4 seconds to turn off the server.
v If an optional Remote Supervisor Adapter II SlimLine is installed in the server, the
server can be turned off from the Remote Supervisor Adapter II SlimLine user interface.
v If the Wake on LAN feature turned on the server, the Wake on LAN feature can
turn off the server.
v Yo u can turn off the server through a request from the service processor.
34 IBM System x3800 Type 8866: Installation Guide
Chapter 4. Configuring the server
The ServerGuide Setup and Installation CD provides software setup tools and installation tools that are specifically designed for your IBM server. Use this CD during the initial installation of the server to configure basic hardware features and to simplify the operating-system installation.
In addition to the ServerGuide Setup and Installation CD, you can use the following configuration programs to customize the server hardware:
v Configuration/Setup Utility program
v Baseboard management controller utility programs
v SAS/SATA Configuration Utility program
v ServeRAID Manager
v PXE boot utility program
v Remote Supervisor II Web interface
more information about these programs, see “Configuring the server” in the
For
User’s Guide on the IBM System x Documentation CD.
Using the ServerGuide Setup and Installation CD
The ServerGuide Setup and Installation CD provides programs to detect the server model and installed hardware options, configure the server hardware, provide device drivers, and help you install the operating system. For information about the supported operating-system versions, see the label on the CD. If the ServerGuide
Setup and Installation CD did not come with the server, you can download the latest
version from http://www.ibm.com/pc/qtechinfo/MIGR-4ZKPPT.html.
To start the ServerGuide Setup and Installation CD, complete the following steps:
1. Insert the CD, and restart the server. If the CD does not start, see Troubleshooting tables.
2. Follow the instructions on the screen to:
a. Select your language.
b. Select your keyboard layout and country.
c. View the overview to learn about ServerGuide features.
d. View the readme file to review installation tips about your operating system
and adapter.
e. Start the setup and hardware configuration programs.
f. Start the operating-system installation. You will need your operating-system
CD.
Using the Configuration/Setup Utility program
The Configuration/Setup Utility program is part of the BIOS code. You can use it to:
v Change interrupt request (IRQ) settings
v Change the startup drive sequence
v Configure serial-connector assignments
v Enable USB keyboard and mouse support
v Resolve configuration conflicts
© Copyright IBM Corp. 2006 35
v Set the date and time
v Set passwords and security settings
Complete the following steps to start the Configuration/Setup Utility program:
1. Turn on the server.
2. When the message Press F1 for Configuration/Setup appears, press F1. If
an administrator password has been set, you must type the administrator password to access the full Configuration/Setup Utility menu.
3. Follow the instructions on the screen.
Installing and using the baseboard management controller utility programs
The baseboard management controller provides environmental monitoring for the server. If environmental conditions exceed thresholds or if system components fail, the baseboard management controller lights LEDs to help you diagnose the problem and also records the error in the BMC system event log.
The baseboard management controller also provides the following remote server management capabilities through the OSA SMBridge management utility program:
v Command-line interface (IPMI Shell)
The command-line interface provides direct access to server management functions through the IPMI 2.0 protocol. Use the command-line interface to issue commands to control the server power, view system information, and identify the server. You can also save one or more commands as a text file and run the file as a script.
v Serial over LAN
Establish a Serial over LAN (SOL) connection to manage servers from a remote location. You can remotely view and change the BIOS settings, restart the server, identify the server, and perform other management functions. Any standard Telnet client application can access the SOL connection.
The server Ethernet ports are set to DHCP by default. The BMC MAC
Note:
address can be found on a tag on the front of the server. Once you have deployed the server, remove the tag so that it does not impede airflow through the front of the server.
For more information about IPMI 2.0, see the Intelligent Platform Management Interface Specification (IPMI Specification), version 2.0, available at http://www.intel.com.
Using the baseboard management controller utility programs
Use the baseboard management controller utility programs to configure the baseboard management controller, download firmware updates, and remotely manage a network.
Using the baseboard management controller configuration utility program
Use the baseboard management controller configuration utility program to view or change the baseboard management controller configuration settings. You can also use the utility program to save the configuration to a file for use on multiple servers.
36 IBM System x3800 Type 8866: Installation Guide
Go to http://www.ibm.com/servers/eserver/support/xseries/index.html to download the utility program; then, copy the bmc_cfg.exe file to a configuration utility diskette on a USB diskette drive.
To start the baseboard management controller configuration utility program, complete the following steps:
1. Insert the configuration utility diskette into the diskette drive and restart the server.
2. From a command-line prompt, type bmc_cfg and press Enter.
3. Follow the instructions on the screen.
the User’s Guide on the IBM System x Documentation CD for details.
See
Using the SAS/SATA Configuration Utility program
To start the SAS/SATA Configuration Utility program, complete the following steps:
1. Turn on the server.
2. When the prompt <<< Press <CTRL><A> for Adaptec SAS/SATA Configuration
Utility! >>> appears, press Ctrl+A.
3. To select a choice from the menu, use the arrow keys.
4. Follow the instructions on the screen to change the settings of the selected items, and press Enter.
Using the ServeRAID configuration programs
A ServeRAID controller enables you to configure multiple physical hard disk drives to operate as logical drives in a disk array. The controller comes with a CD containing the ServeRAID Manager program and the ServeRAID Mini-Configuration program, which you can use to configure the ServeRAID controller. For information about these programs, see the documentation that comes with the ServeRAID controller and the User’s Guide on the IBM System x Documentation CD. If your server comes with an operating system installed, such as Microsoft Windows 2000 Datacenter Server, see the software documentation that comes with the server for configuration information.
Using the PXE boot agent utility program
The Preboot Execution Environment (PXE) boot agent utility program is part of the BIOS code. Yo u can use it to specify the startup order of devices and enable or disable operating-system wake-up support.
Note: The server does not support changing the network boot protocol or
specifying the startup order of devices through the PXE boot agent utility program.
Complete the following steps to start the PXE boot agent utility program:
1. Turn on the server.
2. When the Initializing Intel (R) Boot Agent Version X.X.XX PXE 2.0 Build
XXX (WfM 2.0) prompt appears, press Ctrl+S. You have 2 seconds (by default)
to press Ctrl+S after the prompt appears. If the prompt does not appear, use the Configuration/Setup Utility program to enable the Ethernet PXE/DHCP option.
3. Use the arrow keys and press Enter to select a choice from the menu.
4. Follow the instructions on the screen to change the settings of the selected items; then, press Enter.
Chapter 4. Configuring the server 37
Using the Remote Supervisor II Web Interface
The Remote Supervisor II Web Interface is a graphical user interface that you can use to perform many of the tasks that were previously only available through the Configuration/Setup Utility program. The Remote Supervisor II Web Interface is in the Remote Supervisor Adapter II integrated service processor and is accessed using a Web browser on the administrator console or another computer that is connected to the server through the SP serial connector on the rear of the server.
Before using the Remote Supervisor II Web interface, read the following information:
v A Remote Supervisor Adapter II SlimLine must be installed in the server.
v Yo u must have a Web browser to access the Web interface.
v Yo u must know the IP address or the host name of the Remote Supervisor
Adapter II SlimLine that you are connecting to.
v The IP address and the host name can be found in the Configuration/Setup
Utility program or from your network administrator.
v Yo u can connect directly to the server or use an Ethernet network to access the
service processor and the Remote Supervisor Adapter II Web Interface.
v The following cable connections are required:
Crossover cable from the SP connector to a computer.
An Ethernet cable that is connected to an Ethernet network.
the User’s Guide on the IBM System x Documentation CD for instructions.
See
38 IBM System x3800 Type 8866: Installation Guide
Chapter 5. Updating IBM Director
If you plan to use IBM Director to manage the server, you must check for the latest applicable IBM Director updates and interim fixes.
To install the IBM Director updates and any other applicable updates and interim fixes, complete the following steps:
1. Check for the latest version of IBM Director:
a. Go to http://www.ibm.com/servers/eserver/xseries/systems_management/
xseries_sm/dwnl.html.
b. If a newer version of IBM Director than what comes with the server is shown
in the drop-down list, follow the instructions on the Web page to download the latest version.
Install the IBM Director program.
2.
3. Download and install any applicable updates or interim fixes for the server:
a. Go to http://www.ibm.com/servers/eserver/support/xseries/index.html. b. From the Hardware list, select System x3800. c. From the Software list, select the operating environment of the server and
click Go.
d. Under Fixes and drivers, select the choice for your operating system.
e. Select any applicable update or interim fix that you want to download.
f. Click the file link for the executable file to download the file, and follow the
instructions in the readme file to install the update or interim fix.
g. Repeat steps 3e and 3f for any additional updates or interim fixes that you
want to install.
© Copyright IBM Corp. 2006 39
40 IBM System x3800 Type 8866: Installation Guide
Chapter 6. Solving problems
This chapter provides basic troubleshooting information to help you solve some common problems that might occur while you are setting up the server.
If you cannot locate and correct the problem using the information in this chapter, see Appendix A, Getting help and technical assistance in the Problem
Determination and Service Guide on the IBM System x Documentation CD, and the
“Server Support” flowchart in the front of this document.
Diagnostic tools overview
The following tools are available to help you diagnose and solve hardware-related problems:
v POST beep codes
The power-on self-test beep codes indicate the detection of a problem.
One beep indicates successful completion of POST, with no errors.
More than one beep indicates that POST detected a problem. Error messages
also appear during startup if POST detects a hardware-configuration problem.
See “POST beep codes,” and the Problem Determination and Service Guide on the IBM System x Documentation CD for more information.
Troubleshooting tables
v
These tables list problem symptoms and steps to correct the problems. See “Troubleshooting tables” on page 44 for more information.
v Diagnostic programs and error messages
The system diagnostic programs are provided in ROM. These programs test the major components of the server. See the Problem Determination and Service
Guide on the IBM System x Documentation CD for more information.
v Light path diagnostics
Use light path diagnostics to diagnose system errors quickly. See “Light path diagnostics” on page 54 for more information.
POST beep codes
POST emits one beep to signal successful completion. If POST detects a problem during startup, other beep codes might occur. Use the following beep code descriptions to help diagnose and solve problems that are detected during startup.
Note: See the Problem Determination and Service Guide on the IBM System x Documentation CD for more information about the POST beep codes.
One beep
POST was completed successfully without finding any errors.
Two short beeps
The server configuration has changed.
Other beep codes
See the Problem Determination and Service Guide on the IBM System x
© Copyright IBM Corp. 2006 41
Documentation CD for more information about the POST beep codes.
POST error codes
The following table provides an abbreviated list of the error codes and messages that might appear during POST. See the Problem Determination and Service Guide on the IBM System x Documentation CD for more information about the POST error codes and messages. See http://www.ibm.com/servers/eserver/support/xseries/ index.html to check for updated technical information.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
162 Device configuration error.
163 Real-time clock error.
289 A DIMM has been disabled
by the user or by the system.
301 Keyboard or keyboard
controller error.
1. Run the Configuration/Setup Utility program, select Load Default Settings, and save the settings.
2. Reseat the following components:
a. Battery
b. Failing device
c. I/O board
Remove the battery for 60 minutes; then, reinstall the battery
3. and restart the server.
4. Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time.
1. Run the Configuration/Setup Utility program, select Load Default Settings, make sure the date and time are correct, and save the settings.
2. Reseat the following components:
a. Battery
b. I/O board
Replace the components listed in step 2 one at a time, in the
3. order shown, restarting the server each time.
1. If the DIMM was disabled by the user, run the Configuration/Setup Utility program and enable the DIMM.
2. Make sure that the DIMM is installed correctly.
3. Reseat the DIMM.
4. Replace the DIMM.
1. If you have installed a USB keyboard, run the Configuration/Setup Utility program and enable keyboardless operation to prevent the POST error message 301 from being displayed during startup.
2. Reseat the following components:
a. Keyboard connection
b. I/O board
Replace the components listed in step 2 one at a time, in the
3. order shown, restarting the server each time.
42 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
303 Keyboard controller error.
1. Reseat the following components:
a. I/O board
b. Keyboard connection
Replace the components listed in step 1 one at a time, in the
2. order shown, restarting the server each time.
00019xxx Microprocessor x is not
functioning or failed the built-in self-test; check VRM and processor LEDs.
Make sure that microprocessor x is installed correctly. If the problem remains, replace microprocessor x.
1. Reseat the following components:
a. Microprocessor tray
b. (Trained service technician only) Microprocessor x
Replace the following components one at a time, in the order
2. shown, restarting the server each time.
a. (Trained service technician only) Microprocessor x
b. (Trained service technician only) Microprocessor tray
00180xxx A PCI adapter has requested
memory resources that are not available.
1. Change the order of the adapters in the PCI slots. Make sure that the boot device is positioned early in the scan order.
2. Make sure that the settings for the PCI adapter and all other adapters in the Configuration/Setup Utility program are correct. If the memory resource settings are not correct, change them.
3. If all memory resources are being used, remove an adapter to make memory available to the PCI adapter. Disabling the BIOS on the adapter should correct the error. See the documentation that comes with the adapter.
012980xx
012981xx
No update data for microprocessor x
1. Make sure that all microprocessors have the same cache size.
2. Update the BIOS code again.
3. (Trained service technician only) Reseat microprocessor x.
4. (Trained service technician only) Replace microprocessor x.
I9990305 An operating system was not
found.
1. Make sure that a bootable operating system is installed.
2. Run the hard disk drive diagnostic tests.
3. Reseat the following components:
a. Hard disk drive
b. SAS hard disk drive backplane and cables
c. CD drive and cables
d. I/O board
4.
Replace the components listed in step 3 one at a time, in the
order shown, restarting the server each time.
Chapter 6. Solving problems 43
Troubleshooting tables
The following tables list problem symptoms and suggested solutions. See the
Problem Determination and Service Guide on the IBM System x Documentation CD
for more detailed troubleshooting information. If you cannot find the problem in these charts, run the diagnostic programs. If you have run the diagnostic programs, or if running the tests does not diagnose the problem, call for service.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
CD or DVD drive problems Action
The CD or DVD drive is not recognized.
A CD or DVD is not working correctly.
The CD or DVD drive tray is not working.
General problems Action
A cover lock is broken, an LED is not working, or a similar problem has occurred.
Hard disk drive problems Action
Not all drives are recognized by the hard disk drive diagnostic test (the Fixed Disk test).
The server stops responding during the hard disk drive diagnostic test.
A hard disk drive was not detected while the operating system was being started.
1. Make sure that:
v The IDE channel to which the CD or DVD drive is attached (primary or
secondary) is enabled in the Configuration/Setup Utility program.
v All cables and jumpers are installed correctly.
v The correct device driver is installed for the CD or DVD drive.
Run the CD or DVD drive diagnostic programs.
2.
3. Reseat the following components:
a. CD or DVD drive
b. CD or DVD drive cable
c. I/O board
Replace the components listed in step 3 one at a time, in the order shown,
4. restarting the server each time.
1. Clean the CD or DVD.
2. Run the CD or DVD drive diagnostic programs.
3. Reseat the CD or DVD drive.
4. Replace the CD or DVD drive.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release opening.
3. Reseat the CD or DVD drive.
4. Replace the CD or DVD drive.
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a trained service technician.
Remove the drive indicated on the diagnostic tests; then, run the hard disk drive diagnostic test again. If the remaining drives are recognized, replace the drive that you removed with a new one.
Remove the hard disk drive that was being tested when the server stopped responding, and run the diagnostic test again. If the hard disk drive diagnostic test runs successfully, replace the drive that you removed with a new one.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic tests again.
44 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
A hard disk drive passes the diagnostic Fixed Disk Test but the problem remains.
Run the diagnostic SCSI Fixed Disk Test.
Note: This test is not available to servers using RAID or servers with IDE or SATA
hard disk drives.
Intermittent problems Action
A problem occurs only occasionally and is difficult to diagnose.
1. Make sure that:
v All cables and cords are connected securely to the rear of the server and
attached devices.
v When the server is turned on, air is flowing from the fan grille. If there is no
airflow, the fan is not working. This can cause the server to overheat and shut down.
Check the system-error log or BMC log.
2.
Standard or USB keyboard,
Action mouse, or pointing-device problems
All or some keys on the keyboard do not work.
1. (USB keyboard) If you have installed a USB keyboard, run the Configuration/Setup Utility program and enable keyboardless operation to prevent the POST error message 301 from being displayed during startup.
2. (Standard keyboard) If the server is attached to a KVM switch, bypass the KVM switch to eliminate it as a possible cause of the problem: connect the keyboard cable directly to the correct connector on the rear of the server.
3. Make sure that:
v The keyboard cable or USB cable is securely connected to the server and
the keyboard and mouse cables are not reversed.
v The server and the monitor are turned on.
Reseat the following components:
4. a. Keyboard b. I/O board
Replace the components listed in step 4 one at a time, in the order shown,
5. restarting the server each time.
Chapter 6. Solving problems 45
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The mouse or pointing device does not work.
1. (Standard mouse) If the server is attached to a KVM switch, bypass the KVM switch to eliminate it as a possible cause of the problem: connect the mouse or pointing device cable directly to the correct connector on the rear of the server.
2. Make sure that:
v The mouse or pointing-device cable or USB cable is securely connected and
the keyboard and mouse cables are not reversed.
v (Standard mouse) The mouse device drivers are installed correctly.
v (Standard mouse) The mouse is enabled in the Configuration/Setup Utility
program.
v (USB mouse) Keyboardless operation has been enabled in the
Configuration/Setup Utility program.
(USB mouse) If a USB hub is in use, disconnect the USB device from the hub
3. and connect it directly to the server.
4. Reseat the following components: a. Mouse or pointing device b. I/O board
Replace the components listed in step 4 one at a time, in the order shown,
5. restarting the server each time.
46 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Memory problems Action
The amount of system memory that is displayed is less than the amount of installed physical memory.
1. Make sure that:
v No error LEDs are lit on the operator information panel or on the memory
card.
v Memory mirroring does not account for the discrepancy.
v The memory modules are seated correctly.
v Yo u have installed the correct type of memory.
v If you changed the memory, you updated the memory configuration in the
Configuration/Setup Utility program.
v All banks of memory are enabled. The server might have automatically
disabled a memory bank when it detected a problem, or a memory bank might have been manually disabled.
Check the POST error log for error message 289:
2.
v If a DIMM was disabled by a system-management interrupt (SMI), replace
the DIMM.
v If a DIMM was disabled by the user or by POST, run the Configuration/Setup
Utility program and enable the DIMM.
Run memory diagnostics.
3.
4. Make sure there is no memory mismatch when the server is at the minimum memory configuration.
5. Add one pair of DIMMs at a time, making sure the DIMMs match for each pair added.
6. Add one memory card at a time, making sure the memory matches for each card added.
7. Reseat the following components:
a. DIMM
b. Memory card
Replace the components listed in step 7 one at a time, in the order shown,
8. restarting the server each time.
Chapter 6. Solving problems 47
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Microprocessor problems Action
The server emits a continuous beep during POST, indicating that the startup (boot) microprocessor is not working correctly.
1. Correct any errors indicated by the light path diagnostics LEDs (see “Light path diagnostics” on page 54).
2. Make sure that all microprocessors are supported on this server, and that they all match in speed and cache size.
3. (Trained service technician only) Make sure that the microprocessor 1 is seated correctly.
4. Reseat the following components:
a. (Trained service technician only) Microprocessor 1
b. Microprocessor VRM 3 or 4
c. Microprocessor tray
(Trained service technicians only) If there is no indication of which
5. microprocessor has failed, isolate the error by testing with one microprocessor at a time.
6. Replace the following components one at a time, in the order shown, restarting the server each time.
a. (Trained service technician only) Microprocessor 1
b. Microprocessor VRM 3 or 4
c. (Trained service technician only) Microprocessor tray
(Trained service technician only) If there are multiple error codes or light path
7. diagnostics LEDs that indicate a microprocessor error, reverse the locations of two microprocessors to determine whether the error is associated with a microprocessor or with a microprocessor socket. If the error codes or LEDs indicate an error that is associated with microprocessor socket 3 or 4, reverse the locations of VRM 3 and VRM 4.
v If the error is associated with a microprocessor, replace the microprocessor.
v If the error is associated with a VRM, replace the VRM.
v If the error is associated with a microprocessor socket, replace the
microprocessor tray.
Monitor problems Action
Testing the monitor
1. Make sure the monitor cables are firmly connected.
2. Try using a different monitor on the server, or try using the monitor that is being tested on a different server.
3. Run the diagnostic programs. If the monitor passes the diagnostic programs, the problem might be a video device driver.
4. Reseat the following components:
a. Remote Supervisor Adapter II SlimLine (if one is present)
b. I/O board
Replace the components listed in step 4 one at a time, in the order shown,
5. restarting the server each time.
48 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The screen is blank.
1. If the server is attached to a KVM switch, bypass the KVM switch to eliminate it as a possible cause of the problem: connect the monitor cable directly to the correct connector on the rear of the server.
2. Make sure that:
v The server is turned on. v The monitor cables are connected correctly. v The monitor is turned on and the brightness and contrast controls are
adjusted correctly.
v Make sure that no beep codes sounded when the server is turned on.
Important:
In some memory configurations, the 3-3-3 beep code might sound
during POST, followed by a blank monitor screen. If this occurs and the Boot
Fail Count option in the Start Options of the Configuration/Setup Utility
program is enabled, you must restart the server three times to reset the configuration settings to the default configuration (the memory connector or bank of connectors enabled).
3. Make sure that the correct server is controlling the monitor, if applicable.
4. Make sure that damaged BIOS code is not affecting the video.
5. Observe the checkpoint LEDs on the I/O board; if the codes are changing, go to the next step.
The monitor works when you turn on the server, but the screen goes blank when you start some application programs.
1. Make sure that:
v The application program is not setting a display mode that is higher than the
capability of the monitor.
v Yo u installed the necessary device drivers for the application.
Run video diagnostics.
2.
v If the server passes the video diagnostics, the video is good.
v (Trained service technician only) If the server fails the video diagnostics,
reseat the I/O board.
v Replace the I/O board.
Chapter 6. Solving problems 49
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The monitor has screen jitter, or the screen image is wavy, unreadable, rolling, or distorted.
1. If the monitor self-tests show the monitor is working correctly, consider the location of the monitor. Magnetic fields around other devices (such as transformers, appliances, fluorescent lights, and other monitors) can cause screen jitter or wavy, unreadable, rolling, or distorted screen images. If this happens, turn off the monitor.
Attention: Moving a color monitor while it is turned on might cause screen
discoloration.
Move the device and the monitor at least 305 mm (12 in.) apart, and turn on the monitor.
Notes:
a. To prevent diskette drive read/write errors, make sure that the distance
between the monitor and any external diskette drive is at least 76 mm (3 in.).
b. Non-IBM monitor cables might cause unpredictable problems.
Reseat the following components:
2.
a. Monitor
b. Remote Supervisor Adapter II SlimLine (if one is present)
c. I/O board
Replace the components listed in step 2 one at a time, in the order shown,
3. restarting the server each time.
Wrong characters appear on the screen.
1. If the wrong language is displayed, update the BIOS code with the correct language.
2. Reseat the following components:
a. Monitor
b. I/O board
Replace the components listed in step 2 one at a time, in the order shown,
3. restarting the server each time.
Optional-device problems Action
An IBM optional device that was just installed does not work.
1. Make sure that:
v The device is designed for the server (see the ServerProven list at
http://www.ibm.com/servers/eserver/serverproven/compat/us/).
v Yo u followed the installation instructions that came with the device and the
device is installed correctly.
v Yo u have not loosened any other installed devices or cables. v Yo u updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or any other device is changed, you must update the configuration.
Reseat the device that you just installed.
2.
3. Replace the device that you just installed.
50 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
An IBM optional device that used to work does not work now.
1. Make sure that all of the hardware and cable connections for the device are secure.
2. If the device comes with test instructions, use those instructions to test the device.
3. If the failing device is a SCSI device, make sure that:
v The cables for all external SCSI devices are connected correctly. v The last device in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
v Any external SCSI device is turned on. Yo u must turn on an external SCSI
device before turning on the server.
Reseat the failing device.
4.
5. Replace the failing device.
Chapter 6. Solving problems 51
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Power problems Action
The power-control button does not work, and the reset button does work (the server does not start).
Note: The power-control button
will not function until 20 seconds after the server has been connected to ac power.
1. Make sure that the operator information panel power-control button is working correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained service technician only) Reseat the operator information panel
cables, and then repeat steps 1a and 1b.
v (Trained service technician only) If the server starts, reseat the operator
information panel. If the problem remains, replace the operator information panel.
v (Trained service technician only) If the server does not start, bypass the
operator information panel power-control button by using the force power-on jumper; if the server starts, reseat the operator information panel. If the problem remains, replace the operator information panel.
Make sure that the reset button is working correctly:
2.
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained service technician only) Reseat the light path diagnostics panel
cable, and then repeat steps 2a and 2b.
v (Trained service technician only) If the server starts, replace the light path
diagnostics panel.
v If the server does not start, go to step 3.
Make sure that:
3.
v The power cords are correctly connected to the server and to a working
electrical outlet.
v The type of memory that is installed is correct. v The memory card is fully seated. v The LEDs on the power supply do not indicate a problem. v The microprocessors are installed in the correct sequence.
Reseat the following components:
4.
a. Memory card
b. (Trained service technician only) Power switch connector
c. (Trained service technician only) Power backplane
d. I/O board
Replace the components listed in step 4 one at a time, in the order shown,
5. restarting the server each time.
6. If you just installed an optional device, remove it, and restart the server. If the server now turns on, you might have installed more devices than the power supply supports.
52 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The server does not turn off.
1. Determine whether you are using an Advanced Configuration and Power Management (ACPI) or a non-ACPI operating system. If you are using a non-ACPI operating system, complete the following steps:
a. Press Ctrl+Alt+Delete.
b. Turn off the server by holding the power-control button for 5 seconds.
c. Restart the server.
d. If the server fails POST and the power-control button does not work,
disconnect the ac power cord for 20 seconds; then, reconnect the ac power cord and restart the server.
If the problem remains or if you are using an ACPI-aware operating system,
2. suspect the I/O board.
The server unexpectedly shuts down, and the LEDs on the
See the Problem Determination and Service Guide on the IBM System x
Documentation CD for more information.
operator information panel are not lit.
Serial port problems Action
The number of serial ports that are identified by the operating system is less than the number of installed serial ports.
1. Make sure that:
v Each port is assigned a unique address in the Configuration/Setup Utility
program and none of the serial ports is disabled.
v The serial-port adapter (if one is present) is seated correctly.
Reseat the serial port adapter.
2.
3. Replace the serial port adapter.
For
more information about the serial port, see the User’s Guide on the IBM
System x Documentation CD.
A serial device does not work.
1. Make sure that:
v The device is compatible with the server. v The serial port is enabled and is assigned a unique address. v The device is connected to the correct port.
Reseat the following components:
2.
a. Failing serial device
b. Serial cable
c. Remote Supervisor Adapter II SlimLine (if one is present)
d. I/O board
Replace the components listed in step 2 one at a time, in the order shown,
3. restarting the server each time.
For
more information about the serial port, see the User’s Guide on the IBM
System x Documentation CD.
ServerGuide problems Action
The ServerGuide Setup and Installation CD will not start.
v Make sure that the server supports the ServerGuide program and has a
startable (bootable) CD (or DVD) drive.
v If the startup (boot) sequence settings have been altered, make sure that the CD
drive is first in the startup sequence.
v If more than one CD drive is installed, make sure that only one drive is set as
the primary drive. Start the CD from the primary drive.
Chapter 6. Solving problems 53
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
The SCSI RAID program cannot view all installed drives, or the
v Make sure that there are no duplicate SCSI IDs or IRQ assignments. v Make sure that the hard disk drive is connected correctly.
operating system cannot be installed.
The operating-system
Make more space available on the hard disk. installation program continuously loops.
The ServerGuide program will not start the operating-system CD.
The operating system cannot be installed; the option is not available.
Make sure that the operating-system CD is supported by the ServerGuide program.
See the ServerGuide Setup and Installation CD label for a list of operating-system
versions that support the ServerGuide program.
Make sure that the operating system is supported on the server. If the operating
system is supported, either there is no logical drive defined (SCSI RAID systems)
or the ServerGuide System Partition is not present. Run the ServerGuide program
and make sure that setup is complete.
Software problems Action
You suspect a software problem.
1. To determine whether the problem is caused by the software, make sure that:
v The server has the minimum memory that is needed to use the software. For
memory requirements, see the information that comes with the software. If you have just installed an adapter or memory, the server might have a memory-address conflict.
v The software is designed to operate on the server. v Other software works on the server. v The software works on another server.
If you received any error messages when using the software, see the
2. information that comes with the software for a description of the messages and suggested solutions to the problem.
3. Contact your place of purchase of the software.
Universal Serial Bus (USB)
Action
port device problems
A USB device does not work.
1. Run USB diagnostics.
2. Make sure that:
v The correct USB device driver is installed. v The operating system supports USB devices. v A standard PS/2 keyboard or mouse is not connected to the server. If it is, a
USB keyboard or mouse will not work during POST.
Make sure that the USB configuration options are set correctly in the
3. Configuration/Setup Utility program menu (see the User’s Guide for more information).
4. If you are using a USB hub, disconnect the USB device from the hub and connect it directly to the server.
Light path diagnostics
Light path diagnostics is a system of LEDs on various external and internal components of the server. When an error occurs, LEDs are lit throughout the server. By viewing the LEDs in a particular order, you can often identify the source of the error.
54 IBM System x3800 Type 8866: Installation Guide
The server is designed so that LEDs remain lit when the server is connected to an ac power source but is not turned on, provided that the power supply is operating correctly. This feature helps you to isolate the problem when the operating system is shut down.
Any memory, microprocessor, or VRM LED can be lit again without ac power after you remove the microprocessor tray so that you can isolate a problem. After ac power has been removed from the server, power remains available to these LEDs for up to 24 hours.
To view the memory, microprocessor, or VRM LEDs, press and hold the light path diagnostics button on the memory card or on the microprocessor board briefly to light the error LEDs.
The LEDs that were lit while the server was running will be lit again while the button is pressed.
Many errors are first indicated by a lit information LED or system-error LED on the operator information panel on the front of the server. If one or both of these LEDs are lit, one or more LEDs elsewhere in the server might also be lit and can direct you to the source of the error.
Before working inside the server to view light path diagnostics LEDs, read the safety information that begins on page v and “Handling static-sensitive devices” on page 9.
If an error occurs, view the light path diagnostics LEDs in the following order:
1. Check the operator information panel on the front of the server.
v If the information LED is lit, it indicates that information about a suboptimal
condition in the server is available in the BMC log or in the system-error log.
v If the system-error LED is lit, it indicates that an error has occurred; go to
step 3 on page 56.
The following illustration shows the operator information panel.
Power-control button
USB connector
Power-on LED
Hard disk drive activity LED
Locator LED
Information LED
Release latch
System-error LED
2. Unlock the front cover (tower model only) and remove the server cover to look inside the server for lit LEDs. Certain components inside the server have LEDs that will be lit to indicate the location of a problem. For example, a VRM error will light the LED next to the failing VRM on the microprocessor tray.
The following illustration shows the LEDs and connectors on the microprocessor tray.
Chapter 6. Solving problems 55
Light path diagnostics button
Fan 6
Fan 2
Fan 7
Memory card 1
Fan 3
Memory card 2
Memory card 3
Fan 8
Fan 5
Fan 1
Microprocessor 1 socket
Microprocessor 2 socket
11 22
Microprocessor 1 error LED
Microprocessor 2
44
33
Microprocessor 3 error LED
Microprocessor 3 socket
Microprocessor 4 error LED
Microprocessor 4 socket
error LED
The following illustration shows the LEDs on the PCI board.
PCI attention LEDs
Memory card 4
Microprocessor card error LED
Fan 4
Microprocessor 3 VRM connector
Microprocessor 4 VRM connector
VRM 4 error LED
VRM 3 error LED
PCI power LEDs
Power good LED
3. To view the light path diagnostics panel, press the release latch on the front of the operator information panel to the left; then, slide it forward. This reveals the light path diagnostics panel. Lit LEDs on this panel indicate the type of error that has occurred.
56 IBM System x3800 Type 8866: Installation Guide
Light Path
Diagnostics
PS
REMIND
OVER SPEC
CPU
MEM
VRM
NMI
LINK
LOG
PCI
Remind button
DASD
TEMP
CPU BRD
RAID
FAN
I/O
BRD
SP
NONRED
PCI
BRD
Look at the system service label on the top of the server, which gives an overview of internal components that correspond to the LEDs on the light path diagnostics panel. This information and the information in “Light path diagnostics panel” can often provide enough information to correct the error.
You can use the remind button on the light path diagnostics panel to put the system-error LED on the operator information panel into Remind mode. When you press the remind button, you acknowledge the error but indicate that you will not take immediate action. The system-error LED flashes while it is in Remind mode and stays in Remind mode until one of the following conditions occurs:
v All known errors are corrected. v The server is restarted. v A new error occurs, causing the system-error LED to be lit again.
Light path diagnostics panel
The following table lists the LEDs on the light path diagnostics panel, the problems that they indicate, and actions to solve the problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path diagnostics LED with the system-error LED also lit Description Action
All LEDs off (the power LED is lit).
No action necessary.
Chapter 6. Solving problems 57
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path diagnostics LED with the system-error LED also lit Description Action
OVERSPEC There is insufficient power to power
the system. The NON RED and LOG LEDs might also be lit.
1. Check that ac power is available to all power supplies.
2. Replace any failed power supply.
3. Reseat the following components:
a. Power supply
b. Microprocessor tray
Remove optional devices.
4.
5. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Power supply
b. (Trained service technician only)
Microprocessor tray
PS A power supply or power supply
filler has failed or has been removed.
Note: In a redundant power
configuration, the dc power LED on one power supply might be off.
1. Reinstall the removed power supply or power supply filler.
2. Check the individual power-supply LEDs to find the failing power supply or power supply filler.
3. Reseat the following components:
a. Failing power supply or power supply filler
b. Microprocessor tray
Replace the following components one at a time,
4. in the order shown, restarting the server each time:
a. Failing power supply or power supply filler
b. (Trained service technician only)
Microprocessor tray
If a 12 V fault has occurred, remove ac power
5. before restoring dc power.
LINK Reserved for future use
58 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path diagnostics LED with the system-error LED also lit Description Action
CPU A microprocessor has failed, is
missing, or has been improperly installed.
Note: Make sure that the
microprocessors are installed in the correct sequence; see “Installing an additional microprocessor” on page
17.
1. Check the BMC log or the system-error log to determine the reason for the lit LED.
2. Find the failing, missing, or mismatched microprocessor by checking the LEDs on the microprocessor tray.
3. Reseat the following components:
a. Microprocessor tray
b. (Trained service technician only) Failing
microprocessor
Replace the following components one at a time,
4. in the order shown, restarting the server each time:
a. (Trained service technician only) Failing
microprocessor
b. (Trained service technician only)
Microprocessor tray
VRM A dc-dc regulator has failed or is
missing.
1. Check the BMC log or the system-error log to determine the reason for the lit LED (for a VRM).
2. Find the failing or missing VRM by checking the LEDs on the microprocessor tray.
3. Install any missing VRMs.
4. Reseat the following components:
a. Failing VRM
b. (Trained service technician only)
Microprocessor associated with the VRM
c. Microprocessor tray
Replace the following components one at a time,
5. in the order shown, restarting the server each time:
a. Failing VRM
b. (Trained service technician only)
Microprocessor associated with the VRM
c. (Trained service technician only)
Microprocessor tray
LOG Information is present in the BMC
log and system-error log. One or both logs might be full or almost full.
1. Save the log if necessary. Then, clear the log.
2. Check the log for possible errors.
Chapter 6. Solving problems 59
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path diagnostics LED with the system-error LED also lit Description Action
MEM Memory failure.
Note: The error LED on the
memory card might also be lit.
1. Remove the memory card with the lit error LED on the top of the card; then, press the light path diagnostics button on the memory card to identify the failed DIMM.
2. Reseat the DIMM.
3. Replace the following components one at a time, in the order shown, restarting the server each time:
a. DIMM
b. Memory card
c. (Trained service technician only)
Microprocessor tray
NMI A hardware error has been reported
to the operating system.
Note: The PCI or MEM LED might
also be lit.
1. See the BMC log and the system-error log.
2. If the PCI LED is lit, follow the instructions for that LED.
3. If the MEM LED is lit, follow the instructions for that LED.
4. Restart the server.
PCI A PCI adapter has failed.
Note: The error LED next to the
failing adapter on the PCI board is also lit.
1. See the BMC log or the system-error log.
2. Reseat the following components:
a. Failing adapter
b. I/O board
Replace the components listed in step 2 one at a
3. time, in the order shown, restarting the server each time.
SP There is a fault in the Remote
Supervisor Adapter II SlimLine.
1. Reseat the Remote Supervisor Adapter II SlimLine.
2. Update the firmware for the Remote Supervisor Adapter II SlimLine.
3. Replace the Remote Supervisor Adapter II SlimLine.
60 IBM System x3800 Type 8866: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path diagnostics LED with the system-error LED also lit Description Action
DASD A hard disk drive has failed or has
been removed.
Note: The error LED on the failing
hard disk drive might also be lit.
1. Reinstall the removed drive.
2. Reseat the following components:
a. Failing hard disk drive
b. SAS hard disk drive backplane cables
c. I/O board
Replace the following components one at a time,
3. in the order shown, restarting the server each time:
a. Failing hard disk drive
b. SAS hard disk drive backplane cables
c. SAS backplane
d. I/O board
RAID The RAID adapter (ServeRAID-8i)
has indicated a fault.
1. Check the BMC log or the system-error log for information.
2. Reseat the following components:
a. RAID adapter
b. Hard disk drives
c. I/O board
Replace the components in step 2 one at a time,
3. in the order shown, restarting the server each time.
NONRED The server is operating with
nonredundant power. If a power supply or ac power source fails, the system will be over spec.
Note: The LOG LED might also be
1. If the PS LED on the light path diagnostics panel is lit, follow the instructions for that LED.
2. Replace the failing power supply.
3. Remove optional devices.
lit.
TEMP A system temperature or component
has exceeded specifications.
Note: A fan LED might also be lit.
1. See the BMC log or the system-error log for the source of the fault.
2. Make sure that the airflow in the server is not blocked.
3. If a fan LED is lit, reseat the fan.
4. Replace the fan for which the LED is lit.
5. Make sure that the room is neither too hot nor too cold (see “Environment” in “Features and specifications” on page 4).
6. If one of the integrated VRMs indicates “hot,” remove ac power before restoring dc power.
Chapter 6. Solving problems 61
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path diagnostics LED with the system-error LED also lit Description Action
FAN A fan has failed or has been
removed.
Note: A failing fan can also cause
the TEMP LED to be lit.
1. Reinstall the removed fan.
2. If an individual fan LED is lit, replace the fan.
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the microprocessor tray.
PCI BRD The PCI board has failed.
1. (Trained service technician only) Reseat the PCI board assembly.
2. Run diagnostic program
3. (Trained service technician only) Replace the PCI board assembly.
CPU BRD The microprocessor tray has failed.
1. (Trained service technician only) Reseat the microprocessor tray.
2. Run diagnostic program
3. (Trained service technician only) Replace the microprocessor tray.
I/O BRD The I/O board has failed.
1. Reseat the I/O board.
2. Replace the I/O board.
62 IBM System x3800 Type 8866: Installation Guide
Appendix. Getting help and technical assistance
If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your system or optional device, and whom to call for service, if it is necessary.
Before you call
Before you call, make sure that you have taken these steps to try to solve the problem yourself:
v Check all cables to make sure that they are connected.
v Check the power switches to make sure that the system and any optional
devices are turned on.
v Use the troubleshooting information in your system documentation, and use the
diagnostic tools that come with your system. Information about diagnostic tools is in the Hardware Maintenance Manual and Troubleshooting Guide or Problem
Determination and Service Guide on the IBM System x Documentation CD that
comes with your system.
Note: For some IntelliStation models, the Hardware Maintenance Manual and Troubleshooting Guide is available only from the IBM support Web site.
v Go to the IBM support Web site at http://www.ibm.com/servers/eserver/support/
xseries/index.html to check for technical information, hints, tips, and new device drivers or to submit a request for information.
can solve many problems without outside assistance by following the
You troubleshooting procedures that IBM provides in the online help or in the documentation that is provided with your IBM product. The documentation that comes with IBM systems also describes the diagnostic tests that you can perform. Most systems, operating systems, and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes. If you suspect a software problem, see the documentation for the operating system or program.
Using the documentation
Information about your IBM system and preinstalled software, if any, or optional device is available in the documentation that comes with the product. That documentation can include printed documents, online documents, readme files, and help files. See the troubleshooting information in your system documentation for instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. To access these pages, go to http://www.ibm.com/servers/eserver/support/xseries/ index.html the IBM Publications Center at http://www.ibm.com/shop/publications/order/.
and follow the instructions. Also, some documents are available through
© Copyright IBM Corp. 2006 63
Getting help and information from the World Wide Web
On the World Wide Web, the IBM Web site has up-to-date information about IBM systems, optional devices, services, and support. The address for IBM System x and xSeries information is http://www.ibm.com/systems/x/. The address for IBM IntelliStation information is http://www.ibm.com/intellistation/.
You can find service information for IBM systems and optional devices at http://www.ibm.com/servers/eserver/support/xseries/index.html.
Software service and support
Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with System x and xSeries servers, BladeCenter products, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country or region, see http://www.ibm.com/services/sl/products/.
For more information about Support Line and other IBM services, see http://www.ibm.com/services/, or see http://www.ibm.com/planetwide/ for support telephone numbers. In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).
Hardware service and support
Important: When you call for service, you will be asked to provide the four-digit
machine type of your system, which is 8866.
You can receive hardware service through IBM Services or through your IBM reseller, if your reseller is authorized by IBM to provide warranty service. See http://www.ibm.com/planetwide/ for support telephone numbers, or in the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).
In the U.S. and Canada, hardware service and support is available 24 hours a day, 7 days a week. In the U.K., these services are available Monday through Friday, from 9 a.m. to 6 p.m.
IBM Taiwan product service
IBM Taiwan product service contact information:
IBM Taiwan Corporation 3F, No 7, Song Ren Rd. Taipei, Taiwan Telephone: 0800-016-888
64 IBM System x3800 Type 8866: Installation Guide
Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A.
Trademarks
INTERNATIONAL
BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both:
Active Memory IBM TechConnect Active PCI IBM (logo) Tivoli Active PCI-X IntelliStation Tivoli Enterprise AIX NetBAY Update Connector Alert on LAN Netfinity Wake on LAN
© Copyright IBM Corp. 2006 65
BladeCenter Predictive Failure Analysis XA-32 Chipkill ServeRAID XA-64 e-business logo ServerGuide X-Architecture
Eserver ServerProven XpandOnDemand
FlashCopy System x xSeries i5/OS
Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other countries.
Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
Adaptec and HostRAID are trademarks of Adaptec, Inc., in the United States, other countries, or both.
Important notes
Linux is a trademark of Linus Torvalds in the United States, other countries, or both.
Red Hat, the Red Hat “Shadow Man” logo, and all Red Hat-based trademarks and logos are trademarks or registered trademarks of Red Hat, Inc., in the United States and other countries.
Other company, product, or service names may be trademarks or service marks of others.
Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance.
CD drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum possible.
When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately 1000 bytes, MB stands for approximately 1 000 000 bytes, and GB stands for approximately 1 000 000 000 bytes.
When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM.
Maximum memory may require replacement of the standard memory with an optional memory module.
66 IBM System x3800 Type 8866: Installation Guide
IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties.
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM.
Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
Product recycling and disposal
This unit must be recycled or discarded according to applicable local and national regulations. IBM encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. IBM offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products. Information on IBM product recycling offerings can be found on IBM’s Internet site at http://www.ibm.com/ibm/ environment/products/prp.shtml.
Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en la normativa nacional o local aplicable. IBM recomienda a los propietarios de equipos de tecnología de la información (TI) que reciclen responsablemente sus equipos cuando éstos ya no les sean útiles. IBM dispone de una serie de programas y servicios de devolución de productos en varios países, a fin de ayudar a los propietarios de equipos a reciclar sus productos de TI. Se puede encontrar información sobre las ofertas de reciclado de productos de IBM en el sitio web de IBM http://www.ibm.com/ibm/environment/products/prp.shtml.
Notice: This mark applies only to countries within the European Union (EU) and
Norway.
This appliance is labeled in accordance with European Directive 2002/96/EC concerning waste electrical and electronic equipment (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
Notices 67
Remarque : Cette marque s’applique uniquement aux pays de l’Union Européenne
et à la Norvège.
L’etiquette du système respecte la Directive européenne 2002/96/EC en matière de Déchets des Equipements Electriques et Electroniques (DEEE), qui détermine les dispositions de retour et de recyclage applicables aux systèmes utilisés à travers l’Union européenne. Conformément à la directive, ladite étiquette précise que le produit sur lequel elle est apposée ne doit pas être jeté mais être récupéré en fin de vie.
In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, recycling, and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. For proper collection and treatment, contact your local IBM representative.
Battery return program
This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be recycled or disposed of properly. Recycling facilities may not be available in your area. For information on disposal of batteries outside the United States, go to http://www.ibm.com/ibm/environment/ products/batteryrecycle.shtml or contact your local waste disposal facility.
In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333. Have the IBM part number listed on the battery available prior to your call.
For Taiwan: Please recycle batteries.
For the European Union:
68 IBM System x3800 Type 8866: Installation Guide
For California: Perchlorate material special handling may apply. See
http://www.dtsc.ca.gov/hazardouswaste/perchlorate/.
The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchlorate Materials. This product/part may include a lithium manganese dioxide battery which contains a perchlorate substance.
Electronic emission notices
Federal Communications Commission (FCC) statement
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d’Industrie Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Australia and New Zealand Class A statement
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
United Kingdom telecommunications safety requirement
Notice to Customers
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect connection to public telecommunication systems in the United Kingdom.
Notices 69
European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards.
This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN
55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
Taiwanese Class A warning statement
Chinese Class A warning statement
Japanese Voluntary Control Council for Interference (VCCI) statement
70 IBM System x3800 Type 8866: Installation Guide
Index
A
AC power LED 32 adapter
installing
hot-plug
21
Remote Supervisor Adapter II SlimLine 21 ServeRAID 21
attention notices 3
B
baseboard management controller utility programs 36 bays 4 beep codes 41 bezel
installing
26
removing 11 , 26
C
cable
routing
27
cabling
external
27
the server 27 cache 4 caution statements 3 CD drive problems 44 CD-eject button 30 CD-ROM drive activity LED 30 Class A electronic emission notice 69 components 5 configuration
Configuration/Setup
Utility program 35
SAS/SATA Utility program 37 configuring hardware 35 connectors 31
cable 27
external 27
front 27
rear 27 cover
installing
25
removing 10, 11, 25 CPU BRD LED 62
D
danger statements 3 DC power LED 32 dimensions 4 documentation CD 2 drive
hot-swap
installing drives 4 DVD drive problems 44
12
E
electrical input 4 electronic emission Class A notice 69 environment 4 error messages, POST 42 error symptoms
CD-ROM
drive, DVD-ROM drive 44
general 44 hard disk drive 44 intermittent 45 keyboard, non-USB 45 memory 47 microprocessor 48 mouse, non-USB 45 optional devices 50 pointing device, non-USB 45 power 52 serial port 53 software 54
USB port 54 Ethernet connector 31 Ethernet transmit/receive activity LED 31, 32 expansion bays 4 expansion slots 4 external
cabling
27
F
fan error LED 32 FCC Class A notice 69 features 4 filler panel, hard disk drive bay 13 firmware code, updating 36 firmware updates 1 front cover
installing
26
Front cover
removing
10
G
Gigabit Ethernet connector 32
H
hard disk drive
problems
status LED 30 heat output 4 hot-plug adapter.
See
hot-swap drive
installing humidity 4
44
adapter
12
© Copyright IBM Corp. 2006 71
I
I/O board error LED 32 I/O BRD LED 62 IBM Director 39 important notices 3 installation
adapter
21
completing 25
installing
bezel
26
cover 25 front cover 26
integrated
baseboard
management controller utility
programs 36 integrated functions 4 intermittent problems 45
K
keyboard connector 32 keyboard problems 45
L
LEDs 31
light path diagnostic panel 56 light path, viewing without power 55 microprocessor tray assembly 55 operator information panel 55 PCI board 56
LEDs, light path
CPU
BRD 62
I/O BRD 62
PCI BRD 62 light path diagnostics 54 light path diagnostics LEDs 57 link LED 31, 32
M
memory 4 memory problems 47 microprocessor 4
problems 48 mouse connector 32
N
noise emissions 4 notes 3 notes, important 66 notices
electronic
FCC, Class A 69 notices and statements 3
emission 69
O
online documentation 1 operator information panel 29 optional device problems 50
P
PCI BRD LED 62 POST error messages 42 power cord connector 33 power LED 30 power problems 52 power requirement 4 power supply 4 power-control button 29 power-control-button shield 29 power-cord connector 31 Preboot Execution Environment boot agent utility
program 37
problems
CD-ROM,
DVD-ROM drive 44
hard disk drive 44 intermittent 45 memory 47 microprocessor 48 mouse 45, 46 optional devices 50 pointing device 46 power 52 serial port 53 software 54 solving 41 USB port 54
PXE boot agent utility program 37
R
RAID configuration programs 37 RAID controller 22 remind button 57 Remote Supervisor Adapter II SlimLine error LED 32 Remote Supervisor Adapter II Web User Interface 38
S
SAS
activity
LED 30
SAS/SATA Utility program 37 serial connector 32 serial port problems 53 ServeRAID configuration programs 37 ServerGuide 35
error symptoms 54 ServerGuide CD 1 size 4 slots 4 software problems 54 solving problems 41 specifications 4 Standby mode 33
72 IBM System x3800 Type 8866: Installation Guide
statements and notices 3 system-error LED 30
T
temperature 4 top cover
installing
25
removing 10, 11 trademarks 65 troubleshooting chart 44 turning off the server 33 turning on the server 33
U
UI 38 United States electronic emission Class A notice 69 United States FCC Class A notice 69 Universal Serial Bus (USB) problems 54 updating the firmware code 36 USB connector 29, 31 using
baseboard
programs 36 Configuration/Setup Utility program 35 SAS/SATA Utility program 37
management controller utility
V
video connector 31
W
Web UI 38 weight 4
Index 73
74 IBM System x3800 Type 8866: Installation Guide

Part Number: 31R1875
Printed in USA