IBM x3655, System x3655Type 7985, System x3655 Installation Manual

System x3655
Type 7985
Start the server.
Installation Guide
Welcome.
Thank you for buying an IBM server. is based on the X-Architecture technology, and it features superior performance, availability, and affordability.
This server contains information for setting up and configuring your server.
For detailed information about your server, view the publications on the
Your server
Installation Guide
Documentation CD.
Did the server
start correctly?
Ye s
Turn off the server and install options.
Install the server in the rack cabinet
and cable the server and options;
then, restart the server.
Did the server start correctly?
Ye s
Use the IBM
ServerGuide program
to set up and
configure hardware.
Was the
server setup
completed?
No
No
No
Go to the Server Support
flow chart on the reverse
side of this page.
Go to the Server Support flow chart on the reverse
side of this page.
You can also find the most current information about your server at: http://www.ibm.com/servers/ eserver/support/xseries/ index.html.
Ye s
Use
ServerGuide to
install the operating
system?
Ye s
Install applications, such as IBM systems management software and IBM ServeRAID programs
The server is ready to use.
Go to
http://www.ibm.com/support/mysupport/
to register the server.
No
Go to the Web for instructions:
http://www.ibm.com/servers/ eserver/support/xseries/ index.html.
Server Support
Is the server working
correctly?
Ye s
No
Check all cables for loose connections and verify that all optional devices you installed are on the ServerProven list at
http://www.ibm.com/servers/eserver/ serverproven/compat/us/.
Is the problem
solved?
Ye s
No
Register the server. Go to
http://www.ibm.com/support/mysupport/.
View information about IBM Support Line at
http://www.ibm.com/services/sl/products/
or view support telephone numbers at
http://www.ibm.com/planetwide/.
See the troubleshooting information that comes with the server to determine the cause of the problem and the action to take.
Is the problem
solved?
Ye s
No
Update the firmware to the latest level. You can download firmware from
http://www.ibm.com/servers/ eserver/support/xseries/ index.html
Ye s
Is the problem
solved?
View support telephone numbers at
http://www.ibm.com/planetwide/.
Hardware
No Software
Hardware or
software problem?
IBM System x3655 Ty pe 7985
Installation Guid e

Note:
Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 79 and the
Warranty and Support Information document on the IBM Documentation CD.
Third Edition (February 2007)
© Copyright International Business Machines Corporation 2007. All rights reserved.
US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . .1
The IBM System x Documentation CD . . . . . . . . . . . . . . . . .2
Hardware and software requirements . . . . . . . . . . . . . . . .2
Using the Documentation Browser . . . . . . . . . . . . . . . . .2
Notices and statements in this document . . . . . . . . . . . . . . . .3
Features and specifications . . . . . . . . . . . . . . . . . . . . .4
Major components of the server . . . . . . . . . . . . . . . . . . .6
Chapter 2. Installing optional devices . . . . . . . . . . . . . . . .9
Installation guidelines . . . . . . . . . . . . . . . . . . . . . . .9
System reliability guidelines . . . . . . . . . . . . . . . . . . .10
Working inside the server with the power on . . . . . . . . . . . . .10
Handling static-sensitive devices . . . . . . . . . . . . . . . . .11
Removing the cover . . . . . . . . . . . . . . . . . . . . . . .11
Removing the air baffle . . . . . . . . . . . . . . . . . . . . . .12
Installing the air baffle . . . . . . . . . . . . . . . . . . . . . .13
Installing a memory module . . . . . . . . . . . . . . . . . . . .14
Installing a hard disk drive . . . . . . . . . . . . . . . . . . . . .17
Installing an additional microprocessor . . . . . . . . . . . . . . . .19
Removing the riser-card assembly . . . . . . . . . . . . . . . . . .23
Installing the riser-card assembly . . . . . . . . . . . . . . . . . .25
Installing an adapter . . . . . . . . . . . . . . . . . . . . . . .26
Installing the Remote Supervisor Adapter II SlimLine . . . . . . . . . . .28
Replacing the ServeRAID SAS Controller . . . . . . . . . . . . . . .29
Installing an optional tape drive . . . . . . . . . . . . . . . . . . .29
Completing the installation . . . . . . . . . . . . . . . . . . . . .29
Installing the cover . . . . . . . . . . . . . . . . . . . . . .30
Connecting the cables . . . . . . . . . . . . . . . . . . . . .30
Updating the server configuration . . . . . . . . . . . . . . . . .31
Chapter 3. Server controls, LEDs, and power . . . . . . . . . . . . .33
Front view . . . . . . . . . . . . . . . . . . . . . . . . . .33
Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Server power features . . . . . . . . . . . . . . . . . . . . . .36
Turning on the server . . . . . . . . . . . . . . . . . . . . .36
Turning off the server . . . . . . . . . . . . . . . . . . . . .37
Chapter 4. Configuring the server . . . . . . . . . . . . . . . . .39
Using the ServerGuide Setup and Installation CD . . . . . . . . . . . .39
Using the Configuration/Setup Utility program . . . . . . . . . . . . .39
Using the ServeRAID configuration programs . . . . . . . . . . . . . .40
Using the IBM ServeRAID Configuration Utility program . . . . . . . . .40
Using ServeRAID Manager . . . . . . . . . . . . . . . . . . .41
Using the baseboard management controller . . . . . . . . . . . . . .43
Enabling and configuring SOL using the OSA SMBridge management utility
program . . . . . . . . . . . . . . . . . . . . . . . . .43
Installing the OSA SMBridge management utility program . . . . . . . .52
Using the baseboard management controller utility programs . . . . . . .54
Chapter 5. Solving problems . . . . . . . . . . . . . . . . . . .57
Diagnostic tools overview . . . . . . . . . . . . . . . . . . . . .57
© Copyright IBM Corp. 2007 iii
POST beep codes . . . . . . . . . . . . . . . . . . . . . . .57
POST error codes . . . . . . . . . . . . . . . . . . . . . . . .58
Troubleshooting tables . . . . . . . . . . . . . . . . . . . . . .61
CD or DVD drive problems . . . . . . . . . . . . . . . . . . .61
General problems . . . . . . . . . . . . . . . . . . . . . . .62
Hard disk drive problems . . . . . . . . . . . . . . . . . . . .62
Intermittent problems . . . . . . . . . . . . . . . . . . . . . .63
Keyboard, mouse, or pointing-device problems . . . . . . . . . . . .63
Memory problems . . . . . . . . . . . . . . . . . . . . . . .65
Microprocessor problems . . . . . . . . . . . . . . . . . . . .66
Monitor problems . . . . . . . . . . . . . . . . . . . . . . .67
Optional-device problems . . . . . . . . . . . . . . . . . . . .69
Power problems . . . . . . . . . . . . . . . . . . . . . . .70
Serial port problems . . . . . . . . . . . . . . . . . . . . . .71
ServerGuide problems . . . . . . . . . . . . . . . . . . . . .72
Software problems . . . . . . . . . . . . . . . . . . . . . .72
Universal Serial Bus (USB) port problems . . . . . . . . . . . . . .73
Video problems . . . . . . . . . . . . . . . . . . . . . . . .73
Light path diagnostics . . . . . . . . . . . . . . . . . . . . . .73
Diagnosing problems using light path diagnostics . . . . . . . . . . .74
Light path diagnostics LEDs . . . . . . . . . . . . . . . . . . .74
Appendix A. Getting help and technical assistance . . . . . . . . . .77
Before you call . . . . . . . . . . . . . . . . . . . . . . . . .77
Using the documentation . . . . . . . . . . . . . . . . . . . . .77
Getting help and information from the World Wide Web . . . . . . . . . .78
Software service and support . . . . . . . . . . . . . . . . . . .78
Hardware service and support . . . . . . . . . . . . . . . . . . .78
IBM Taiwan product service . . . . . . . . . . . . . . . . . . . .78
Appendix B. Notices . . . . . . . . . . . . . . . . . . . . . .79
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . .79
Important notes . . . . . . . . . . . . . . . . . . . . . . . . .80
Product recycling and disposal . . . . . . . . . . . . . . . . . . .81
Battery return program . . . . . . . . . . . . . . . . . . . . . .82
Electronic emission notices . . . . . . . . . . . . . . . . . . . .83
Federal Communications Commission (FCC) statement . . . . . . . . .83
Industry Canada Class A emission compliance statement . . . . . . . .83
Australia and New Zealand Class A statement . . . . . . . . . . . .83
United Kingdom telecommunications safety requirement . . . . . . . . .83
European Union EMC Directive conformance statement . . . . . . . . .84
Taiwanese Class A warning statement . . . . . . . . . . . . . . .84
Chinese Class A warning statement . . . . . . . . . . . . . . . .84
Japanese Voluntary Control Council for Interference (VCCI) statement . . .84
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
iv IBM System x3655 Type 7985: Installation Guide
Safety
Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt.
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Avant d’installer ce produit, lisez les consignes de sécurité.
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
© Copyright IBM Corp. 2007 v
Antes de instalar este producto, lea la información de seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
Important:
All caution and danger statements in this documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM Safety Information book.
For example, if a caution statement begins with a number 1, translations for that caution statement appear in the IBM Safety Information book under statement 1.
Be sure to read all caution and danger statements in this documentation before performing the instructions. Read any additional safety information that comes with the server or optional device before you install the device.
vi IBM System x3655 Type 7985: Installation Guide
Statement 1:
DANGER
Electrical
current from power, telephone, and communication cables is
hazardous.
To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
v Connect all power cords to a properly wired and grounded electrical
outlet.
v Connect to properly wired outlets any equipment that will be attached to
this product.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached devices.
To Connect: To Disconnect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
5. Turn device ON.
Safety vii
Statement 2:
CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water v Heat to more than 100°C (212°F) v Repair or disassemble
Dispose
of the battery as required by local ordinances or regulations.
viii IBM System x3655 Type 7985: Installation Guide
Statement 3:
CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
v Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
laser products contain an embedded Class 3A or Class 3B laser
Some diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1
`
Safety ix
Statement 4:
18 kg (39.7 lb) 32 kg (70.5 lb) 55 kg (121.2 lb)
CAUTION: Use safe practices when lifting.
Statement 5:
CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2
1
x IBM System x3655 Type 7985: Installation Guide
Statement 8:
CAUTION: Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.
Statement 26:
CAUTION: Do not place any object on top of rack-mounted devices.
Attention: This server is suitable for use on an IT power distribution system
whose maximum phase-to-phase voltage is 240 V under any distribution fault condition.
Safety xi
xii IBM System x3655 Type 7985: Installation Guide
Chapter 1. Introduction
This Installation Guide contains instructions for setting up your IBM® System x3655 Type 7985 server and basic instructions for installing some optional devices. More detailed instructions for installing optional devices are in the User’s Guide on the IBM System x™ Documentation CD, which comes with the server. This document contains information about:
v Setting up and cabling the server
v Starting and configuring the server
v Installing some optional devices
v Solving problems
server has two model styles, which are based on the size and number of hard
The disk drive bays:
v The 3.5-inch models have six 3.5-inch hot-swap hard disk drive bays. Install only
3.5-inch drives in these models. If you install an optional tape drive, the tape drive occupies two of the six 3.5-inch drive bays.
v The 2.5-inch models have eight 2.5-inch hot-swap hard disk drive bays and one
3.5-inch tape drive bay. Install only 2.5-inch hard disk drives and an optional
3.5-inch tape drive in these models.
Throughout this documentation, the terms 2.5-inch models and 3.5-inch models are used to distinguish between the server styles.
If firmware and documentation updates are available, you can download them from the IBM web site. The server might have features that are not described in the documentation that comes with the server, and the documentation might be updated occasionally to include information about those features, or technical updates might be available to provide additional information that is not included in the server documentation. To check for updates, go to http://www.ibm.com/servers/eserver/ support/xseries/index.html, select System x3655 from the Hardware list, and click Go. For firmware updates, click the Download tab. For documentation updates, click the Install and use tab, and click Product documentation.
Note: Changes are made periodically to the IBM Web site. Procedures for locating
firmware and documentation might vary slightly from what is described in this document.
The server comes with an IBM ServerGuide™ Setup and Installation CD to help you configure the hardware, install device drivers, and install the operating system.
The server comes with a limited warranty. You can obtain up-to-date information about the server and other IBM server products at http://www.ibm.com/systems/x/.
© Copyright IBM Corp. 2007 1
Record information about the server in the following table. You will need this information when you register the server with IBM.
Product name IBM System x3655 server
Machine type 7985 Model number _____________________________________________ Serial number _____________________________________________
The model number and serial number are on the ID label on the bezel, as shown in the following illustration.
ID label
Note: This illustration shows a model with 3.5-inch hot-swap hard disk drives.
Models with 2.5-inch hot-swap hard disk drives are also available. The location of the ID label is the same on both model styles. This illustration might differ slightly from your hardware.
For a list of supported optional devices for the server, see the ServerProven® Web site at http://www.ibm.com/servers/eserver/serverproven/compat/us/.
See the Rack Installation Instructions document for complete rack installation and removal instructions.
The IBM System x Documentation CD
The IBM System x Documentation CD contains documentation for your server in Portable Document Format (PDF) and includes the IBM Documentation Browser to help you find information quickly.
Hardware and software requirements
The IBM System x Documentation CD requires the following minimum hardware and software:
v Microsoft® Windows® XP, Windows 2000, or Red Hat Linux.
v 100 MHz microprocessor
v 32 MB of RAM.
v Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
systems.
Using the Documentation Browser
Use the Documentation Browser to browse the contents of the CD, read brief descriptions of the documents, and view documents using Adobe Acrobat Reader or
2 IBM System x3655 Type 7985: Installation Guide
xpdf. The Documentation Browser automatically detects the regional settings in use in your server and displays the documents in the language for that region (if available). If a document is not available in the language for that region, the English-language version is displayed.
Use one of the following procedures to start the Documentation Browser:
v If Autostart is enabled, insert the CD into the CD drive. The Documentation
Browser starts automatically.
v If Autostart is disabled or is not enabled for all users, use one of the following
procedures:
If you are using a Windows operating system, insert the CD into the CD drive
and click Start --> Run. In the Open field, type
e:\win32.bat
where e is the drive letter of the CD drive, and click OK.
If you are using Red Hat Linux, insert the CD into the CD drive; then, run the
following command from the /mnt/cdrom directory:
sh runlinux.sh
Select your server from the Product menu. The Available Topics list displays all the documents for your server. Some documents might be in folders. A plus sign (+) indicates each folder or document that has additional documents under it. Click the plus sign to display the additional documents.
When you select a document, a description of the document appears under Topic Description. To select more than one document, press and hold the Ctrl key while you select the documents. Click View Book to view the selected document or documents in Acrobat Reader or xpdf. If you selected more than one document, all the selected documents are opened in Acrobat Reader or xpdf.
To search all the documents, type a word or word string in the Search field and click Search. The documents in which the word or word string appears are listed in order of the most occurrences. Click a document to view it, and press Crtl+F to use the Acrobat search function or Alt+F to use the xpdf search function within the document.
Click Help for detailed information about using the Documentation Browser.
Notices and statements in this document
The caution and danger statements that appear in this document are also in the multilingual Safety Information document, which is on the IBM System x
Documentation CD. Each statement is numbered for reference to the corresponding
statement in the Safety Information document.
The following notices and statements are used in this document:
v Note: These notices provide important tips, guidance, or advice. v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which damage could occur.
Chapter 1. Introduction 3
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially hazardous procedure step or situation.
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation.
Features and specifications
The following information is a summary of the features and specifications of your server. Depending on the server model, some features might not be available, or some specifications might not apply.
Racks are marked in vertical increments of 4.45 cm (1.75 inches). Each increment is referred to as a unit, or “U.”
4 IBM System x3655 Type 7985: Installation Guide
Table 1. Features and specifications
Microprocessor:
v AMD Opteron dual-core with 2 MB (1
MB per core) Level-2 cache
v 1 GHz Hypertransport interconnect bus v Support for up to two microprocessors
Note: Use the Configuration/Setup Utility
program to determine the type and speed of the microprocessors.
Memory:
v Sixteen DIMM connectors v Minimum: 1 GB v Maximum: 64 GB v Type: Registered, PC2-5300 double data
rate (DDR) II, DIMMS
v Sizes: 512 MB, 1 GB, 2 GB, or
4 GB, in pairs
(depending on your model)
Drives:
v Hard disk drive: SAS or S ATA v One of the following IDE drives:
DVD-ROM CD-RW/DVD-ROM combination
Expansion
v Hot-swap hard disk drive bays: One of
the following configurations: Six 3.5-inch drive bays (optional tape
Eight 2.5-inch drive bays and one
v One 5.25-inch Ultrabay Enhanced bay
(CD-RW/DVD drive installed)
Expansion
v Three low-profile PCI Express slots (two
x8 and one x4 lanes) on system board
v Support for one of the following riser
cards: HTX riser card with a full height, full
PCI Express riser card with a full
PCI-X riser card with one full height,
Hot-swap
v Standard: Five v Maximum: Te n - provide redundant
cooling
bays:
drive will require two of these bays)
tape drive bay
slots:
length HTX adapter slot (25 W max.) (standard)
height, full length adapter slot (x16 lanes) (25 W max.) (optional)
full length, 133 MHz/64-bit adapter slot (optional)
fans:
Hot-swap power supplies:
835 watts (100-240 V ac)
v Minimum: One v Maximum: Two - provide redundant
power
(2 U):
Size
v Height: 85.4 mm (3.36 in.) v Depth: 705 mm (27.8 in.) v Width: 443.6 mm (17.5 in.) v Weight: approximately 21.09 kg (46.5
lb) to 29.03 kg (64 lb) depending upon configuration
Integrated
functions:
v Baseboard management controller or
on-board service control processor
v Tw o Broadcom 10/100/1000 Ethernet
controllers with Wake on LAN® support and TCPIP Offload Engine (TOE) support
v One serial port v One serial-attached SCSI (SAS)
controller
v Six Universal Serial Bus (USB) ports
(2.0) two on the front of the server four on the back of the server
Tw o video ports
v
one on the front of the server one on the rear of the server
v Support for Remote Supervisor Adapter
II SlimLine x
controller:
Video
v AT I RN50 video on system board v Compatible with SVGA and VGA v 16 MB DDR video memory
controller:
RAID
v ServeRAID™-8k-l SAS Controller, 256
MB, that supports RAID levels 0, 1, 10 (standard)
v Upgradable to ServeRAID-8k SAS
Controller, 512 MB with battery backup, that supports additional RAID levels
Acoustical
noise emissions:
v Declared sound power, idle: 6.8 bel v Declared sound power, operating: 6.8
bel
Environment:
v Air temperature:
Server on: 10° to 35°C (50.0° to
95.0°F); altitude: 0 to 914.4 m (3000 ft). Decrease system temperature by
0.75°C for every 1000-foot increase in altitude.
Server off: 10° to 43°C (50.0° to
109.4°F); maximum altitude: 2133 m (7000 ft)
Shipment: -40° to +60°C (-40° to
140°F); maximum altitude: 2133 m (7000 ft)
Humidity:
v
Server on/off: 8% to 80% Shipment: 5% to 100%
output:
Heat
Approximate heat output in British thermal units (Btu) per hour:
v Minimum configuration: 1230 Btu (360
watts)
v Maximum configuration: 2840 Btu (830
watts)
Electrical
input:
v Sine-wave input (50-60 Hz) required v Input voltage range automatically selected v Input voltage low range:
Minimum: 100 V ac Maximum: 127 V ac
Input voltage high range:
v
Minimum: 200 V ac Maximum: 240 V ac
v Input kilovolt-amperes (kVA)
approximately: Minimum: 0.36 kVA Maximum 0.93 kVA
Notes:
1. Power consumption and heat output vary depending on the number and type of optional features that are installed and the power-management optional features in use.
2. These levels were measured in controlled acoustical environments according to the procedures that are specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.
Chapter 1. Introduction 5
Major components of the server
Blue on a component indicates touch points, where you can grip the component to remove it from or install it in the server, open or close a latch, and so on.
Orange on a component or an orange label on or near a component indicates that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component.
The following illustrations show the major components in the server.
Note: The illustrations in this document might differ slightly from your hardware.
CD/DVD media backplane
Tape drive filler
Tape drive space filler
Optional tape drive
Operator information panel
CD/DVD drive
3.5-inch filler panel
3.5-inch hard disk drive
3.5-inch cage divider
Fans (5 or 10)
Fan bracket assembly
3.5-inch hard disk drive backplane
2.5-inch hard disk drive
2.5-inch filler panel
Cover
Power-supply filler
Power supply
Power backplane
2.5-inch drive cage with hard disk drive backplane
6 IBM System x3655 Type 7985: Installation Guide
Remote Supervisor Adapter II SlimLine
Low-profile adapter
Heat sink
Microprocessor
Heat-sink retention module
Riser-card assembly
Full-height adapter
DIMM air baffle
DIMM
ServeRAID SAS controller
System board with shuttle assembly mounted
Shuttle assembly
Chapter 1. Introduction 7
8 IBM System x3655 Type 7985: Installation Guide
Chapter 2. Installing optional devices
This chapter provides basic instructions for installing optional hardware devices in the server. These instructions are intended for users who are experienced with setting up IBM server hardware. If you need more detailed instructions, see the
User’s Guide on the IBM System x Documentation CD.
Installation guidelines
Before you install optional devices, read the following information:
v Read the safety information that begins on page v and the guidelines in
“Handling static-sensitive devices” on page 11. This information will help you work safely.
v When you install your new server, take the opportunity to download and apply
the most recent firmware updates. This step will help to ensure that any known issues are addressed and that your server is ready to function at maximum levels of performance. To download firmware updates for your server, go to http://www.ibm.com/servers/eserver/support/xseries/index.html, select System x3655 from the Hardware list, click Go, and click the Download tab. For additional information about tools for updating, managing, and deploying firmware, see the System x and xSeries Tool Center at http:// publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
v Before you install optional hardware devices, make sure that the server is
working correctly. Start the server, and make sure that the operating system starts, if an operating system is installed, or that a 19990305 error code is displayed, indicating that an operating system was not found but the server is otherwise working correctly. If the server is not working correctly, see Chapter 5, “Solving problems,” on page 57 for diagnostic information.
v Observe good housekeeping in the area where you are working. Place removed
covers and other parts in a safe place.
v If you must start the server while the cover is removed, make sure that no one is
near the server and that no tools or other objects have been left inside the server.
v Do not attempt to lift an object that you think is too heavy for you. If you have to
lift a heavy object, observe the following precautions:
Make sure that you can stand safely without slipping.
Distribute the weight of the object equally between your feet.
Use a slow lifting force. Never move suddenly or twist when you lift a heavy
object.
To avoid straining the muscles in your back, lift by standing or by pushing up
with your leg muscles.
Make sure that you have an adequate number of properly grounded electrical
v
outlets for the server, monitor, and other devices.
v Back up all important data before you make changes to disk drives.
v Have a small flat-blade screwdriver available.
v Yo u do not have to turn off the server to install or replace hot-swap power
supplies, hot-swap fans, or hot-plug Universal Serial Bus (USB) devices. However, you must turn off the server before performing any steps that involve removing or installing adapter cables.
v Blue on a component indicates touch points, where you can grip the component
to remove it from or install it in the server, open or close a latch, and so on.
© Copyright IBM Corp. 2007 9
v Orange on a component or an orange label on or near a component indicates
that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component.
v When you are finished working on the server, reinstall all safety shields, guards,
labels, and ground wires.
v For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
System reliability guidelines
To help ensure proper cooling and system reliability, make sure that the following requirements are met:
v Each of the drive bays has a drive or a filler panel and electromagnetic
compatibility (EMC) shield installed in it.
v If the server has redundant power, each of the power-supply bays has a power
supply installed in it.
v There is adequate space around the server to allow the server cooling system to
work properly. Leave approximately 50 mm (2.0 in.) of open space around the front and rear of the server. Do not place objects in front of the fans. For proper cooling and airflow, replace the server cover before turning on the server. Operating the server for extended periods of time (more than 2 minutes) with the server cover removed might damage server components.
v Yo u have followed the cabling instructions that come with optional adapters.
v Yo u have replaced a failed fan within 48 hours.
v Yo u have replaced a hot-swap drive within 2 minutes of removal.
v Yo u do not operate the server without the air baffle installed. Operating the
server without the air baffle might cause the microprocessor to overheat.
v Microprocessor socket 2 always contains either a microprocessor baffle or a
microprocessor and heat sink.
Working inside the server with the power on
Attention: Static electricity that is released to internal server components when
the server is powered-on might cause the server to halt, which could result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on.
The server supports hot-plug, hot-add, and hot-swap devices and is designed to operate safely while it is turned on and the cover is removed. Follow these guidelines when you work inside a server that is turned on:
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts
before working inside the server; do not wear cuff links while you are working inside the server.
v Do not allow your necktie or scarf to hang inside the server.
v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist
watches.
v Remove items from your shirt pocket, such as pens and pencils, that could fall
into the server as you lean over it.
10 IBM System x3655 Type 7985: Installation Guide
v Do not drop any metallic objects, such as paper clips, hairpins, and screws, into
the server.
Handling static-sensitive devices
Attention: Static electricity can damage the server and other electronic devices.
To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them.
To reduce the possibility of damage from electrostatic discharge, observe the following precautions:
v Limit your movement. Movement can cause static electricity to build up around
you.
v The use of a grounding system is recommended. For example, wear an
electrostatic-discharge wrist strap, if one is available. Always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on
v Handle the device carefully, holding it by its edges or its frame.
v Do not touch solder joints, pins, or exposed circuitry.
v Do not leave the device where others can handle and damage it.
v While the device is still in its static-protective package, touch it to an unpainted
metal surface on the outside of the server for at least 2 seconds. This drains static electricity from the package and from your body.
v Remove the device from its package and install it directly into the server without
setting down the device. If it is necessary to set down the device, put it back into its static-protective package. Do not place the device on the server cover or on a metal surface.
v Take additional care when handling devices during cold weather. Heating reduces
indoor humidity and increases static electricity.
Removing the cover
Attention: Operating the server for more than 2 minutes with the top cover
removed might damage server components. For proper cooling and airflow, replace the top cover before you turn on the server.
To remove the cover, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. If you are planning to install or remove a microprocessor, memory module, PCI adapter, or tape drive, turn off the server and all attached devices and disconnect all external cables and power cords (see “Turning off the server” on page 37).
3. Press down on the left and right side latches and pull the server out of the rack enclosure until both slide rails lock.
Note: Yo u can reach the cables on the back of the server when the server is in
the locked position.
Chapter 2. Installing optional devices 11
4. Lift the cover-release latch. Lift the cover off the server and set the cover aside.
Removing the air baffle
When you work with some optional devices, you must first remove the air baffle to access certain components or connectors on the system board. The following illustration shows how to remove the air baffle.
Cover-release latch
Attention: For proper cooling and airflow, replace the air baffle before you turn on
the server. Operating the server with an air baffle removed might damage server components.
12 IBM System x3655 Type 7985: Installation Guide
Riser card assembly
Release tab
Air baffle
Release tab
To remove the air baffle, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. Turn off the server and peripheral devices and disconnect all power cords and external cables (see “Turning off the server” on page 37); then, remove the cover (see “Removing the cover” on page 11).
3. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 23).
4. Grasp the tabs on each side of the air baffle, and lift the air baffle out of the server.
Installing the air baffle
To install the air baffle, complete the following steps:
Attention: For proper cooling and airflow, replace the air baffle before you turn on
the server. Operating the server with an air baffle removed might damage server components.
Chapter 2. Installing optional devices 13
Riser card assembly
Release tab
Air baffle
Release tab
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. Hold the air baffle by the tabs on each side. Align the front of the air baffle with the rear of the fan bracket assembly and the side of the heat sink on microprocessor number one.
3. Slide the air baffle down into the server until the bottom edge rests on the system board.
Installing a memory module
The following notes describe the types of dual inline memory modules (DIMMs) that the server supports and other information that you must consider when installing DIMMs:
v The server supports up to sixteen Registered DDR2 PC2-5300, 512 MB, 1 GB, 2
GB, and 4 GB DIMMs, for a maximum of 64 GB of system memory. See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of memory modules you can use with the server.
Note: Because some memory is reserved for system operation, the actual
usable memory size reported by the operating system will be less than the total installed size.
14 IBM System x3655 Type 7985: Installation Guide
v The server comes with a minimum of two 512 MB DIMMs installed in connectors
1 and 2. When you install additional DIMMs, you must install two identical DIMMS at a time, in the order shown in the following table, to maintain performance.
Table 2. DIMM installation sequence
DIMMs 1 microprocessor installed 2 microprocessors installed
2 DIMM connectors 1 and 2 Not applicable
4 DIMM connectors 1 through 4 DIMM connectors 1 and 2 and 9 and
10
6 DIMM connectors 1 through 6 DIMM connectors 1 through 4 and 9
and 10
8 DIMM connectors 1 through 8 DIMM connectors 1 through 4 and 9
through 12
10 Not applicable DIMM connectors 1 through 6 and 9
through 12
12 Not applicable DIMM connectors 1 through 6 and 9
through 14
14 Not applicable DIMM connectors 1 through 8 and 9
through 14
16 Not applicable DIMM connectors 1 through 16
v Each DIMM in a pair must be the same size, speed, type, and technology to
ensure that the server will operate correctly.
DIMM 16 DIMM 15 DIMM 14 DIMM 13 DIMM 12 DIMM 11 DIMM 10
DIMM 9
DIMM 8 DIMM 7 DIMM 6 DIMM 5 DIMM 4 DIMM 3 DIMM 2 DIMM 1
v The server supports online-spare memory. This feature disables a failed pair of
DIMMS from the system configuration and activates an online-spare pair of DIMMs to replace the failed pair. Online-sparing is supported on a per processor
Chapter 2. Installing optional devices 15
basis. Each microprocessor requires that two or more pairs of DIMMs be installed to support online sparing. The DIMMs must be the same speed, type, size (or larger), and technology as the failed pair of DIMMs
Enable online-spare memory through the Configuration/Setup Utility program. The BIOS code assigns the online-spare DIMM pairs according to your DIMM configuration.
v When you install or remove DIMMs, the server configuration information
changes. When you restart the server, the system displays a message that indicates that the memory configuration has changed.
To install a DIMM, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables. Remove the cover.
3. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 23).
Attention: To avoid breaking the retaining clips or damaging the DIMM
connectors, open and close the clips gently.
4. Remove the air baffle (see “Removing the air baffle” on page 12).
5. Open the retaining clip on each end of the DIMM connector.
6. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the outside of the server. Then, remove the DIMM from the package.
7. Turn the DIMM so that the key aligns correctly with the connector.
8. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM
has not been correctly inserted; open the retaining clips, remove the DIMM, and then reinsert it.
16 IBM System x3655 Type 7985: Installation Guide
If you have other devices to install, do so now. Otherwise, go to “Completing the installation” on page 29.
Installing a hard disk drive
Locate the documentation that comes with the hard disk drive and follow those instructions in addition to the instructions in this chapter.
The following notes describe the type of hard disk drive that the server supports and other information that you must consider when installing a hard disk drive:
v The 3.5-inch model server supports six, slim, 3.5-inch hot-swap hard disk drives
installed on Ultra-Slim hard disk drive trays for 3.5-inch drives. For a list of supported 3.5-inch hard disk drives, go to the ServerProven Web site at http://www.ibm.com/servers/eserver/serverproven/compat/us.
v The 2.5-inch model server supports eight, 2.5-inch, hot-swap hard disk drives
installed on Ultra-Slim hard disk drive trays for 2.5-inch drives. For a list of supported 2.5-inch hard disk drives, go to the ServerProven Web site at http://www.ibm.com/servers/eserver/serverproven/compat/us .
v All hot-swap drives in the server should have the same throughput speed rating.
Mixing hard disk drives with different speed ratings will cause all drives to operate at the lower throughput speed.
v The ID that is assigned to each bay is printed on the server front.
The following illustrations show how to install a hot-swap hard disk drive.
3.5-inch drives
Important: Install only SAS or SATA 3.5-inch hard disk drives in this server.
Filler panel
Hard disk drive
Tray handle
2.5-inch drives
Important: Install only SAS 2.5-inch hard disk drives in this server.
Chapter 2. Installing optional devices 17
18 IBM System x3655 Type 7985: Installation Guide
Complete the following steps to install a drive in a hot-swap bay.
Attention: To maintain proper system cooling, do not operate the server for more
than 10 minutes without either a drive or a filler panel installed in each bay.
1. Read the safety information that begin on page v, and “Installation guidelines” on page 9.
2. Remove the filler panel from one of the empty hot-swap bays.
3. Install the hard disk drive in the hot-swap bay:
a. Make sure that the tray handle is open (that is, perpendicular to the drive).
b. Align the drive assembly with the guide rails in the bay.
c. Gently push the drive assembly into the bay until the drive stops.
d. Push the tray handle to the closed (locked) position.
e. Check the hard disk drive status LED to verify that the hard disk drive is
operating properly.
If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and must be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
Yo u might have to reconfigure the disk arrays after installing hard disk
Note:
drives. See the RAID documentation on the IBM ServeRAID Support CD for more information.
If you have other devices to install, do so now. Otherwise, go to“Completing the installation” on page 29.
Installing an additional microprocessor
The following notes describe the type of microprocessor that the server supports and other information that you must consider when installing a microprocessor:
v The server supports up to two AMD Opteron microprocessors. If the server
comes with one microprocessor, you can install a second microprocessor but it must be the same type and speed.
v Yo u might have to update the BIOS code. Be sure to read the documentation
that comes with the microprocessor so that you can determine whether you have to update the BIOS code. Yo u can download the latest level of BIOS code and many other code updates for your server at http://www.ibm.com/servers/eserver/ support/xseries/index.html.
v (Optional) Obtain an SMP-capable operating system. For a list of supported
operating systems and other optional devices, go to http://www.ibm.com/servers/ esever/serverproven/compat/us/.
v To order an additional microprocessor, contact your IBM marketing representative
or authorized reseller.
v The microprocessor speeds are automatically set for this server; therefore, you
do not have to set any microprocessor frequency-selection jumpers or switches.
v If you have to replace a microprocessor, call for service.
v If the thermal-grease protective cover (for example, a plastic cap or tape liner) is
removed from the heat sink, do not touch the thermal grease on the bottom of the heat sink or set down the heat sink.
v Do not remove the first microprocessor from the system board to install the
second microprocessor.
Chapter 2. Installing optional devices 19
The following illustration shows the microprocessor connector locations on the system board.
Microprocessor 2 connector
Microprocessor 1 connector
The following illustration shows how to install the second microprocessor on the system board.
20 IBM System x3655 Type 7985: Installation Guide
Heat sink
Microprocessor
Microprocessor socket dust cover
Note: For simplicity, certain components have been removed from this illustration. Attention:
v A startup (boot) processor must always be installed in microprocessor connector
1 on the system board.
v To ensure correct server operation when you install an additional microprocessor,
use microprocessors that have the same cache size and type, and the same clock speed. Microprocessor clock frequencies must be identical.
install an additional microprocessor, complete the following steps:
To
1. Read the safety information that begins on page v, and “Installation guidelines” on page 9.
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables. Remove the server cover.
Attention: When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 11.
3. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 23).
4. Remove the air baffle (see “Removing the air baffle” on page 12).
5. Open the heat-sink release latch to the fully open position.
6. Install the microprocessor:
a. Touch the static-protective package containing the microprocessor to any
unpainted metal surface on the server. Then, remove the microprocessor from the package.
b. Remove the protective dust cover, tape, or label from the surface of the
microprocessor socket, if present.
c. Rotate the microprocessor release lever on the socket from its closed and
locked position until it stops in the fully open position.
Chapter 2. Installing optional devices 21
Microprocessor release lever
Microprocessor socket dust cover
Attention:
v Handle the microprocessor carefully. Dropping the microprocessor during
installation or removal can damage the contacts. Also, contaminant on the microprocessor contacts, such as oil from your skin, can cause connection failures between the contacts and the socket.
v Do not use excessive force when pressing the microprocessor into the
socket.
Align the microprocessor with the socket (note the alignment mark and the
d.
position of the notches); then, carefully place the microprocessor on the socket. Close the microprocessor bracket frame.
Microprocessor
Alignment marks
Notches
Note: The microprocessor fits only one way on the socket.
e. Carefully close the microprocessor release lever to secure the
microprocessor in the socket.
Install the heat sink on the microprocessor.
7.
Attention: Do not touch the thermal grease on the bottom of the heat sink or
set down the heat sink after you remove the plastic cover. Touching the thermal grease will contaminate it. For details, see the information about thermal grease in the User’s Guide on the IBM Documentation CD.
22 IBM System x3655 Type 7985: Installation Guide
Thermal grease
Heat sink
a. Make sure that the heat-sink release lever is in the open position.
b. Remove the plastic protective cover from the bottom of the heat sink.
c. Align the heat sink above the microprocessor with the thermal grease side
down.
Heat sink release lever
d. Slide the rear flange of the heat sink into the opening in the retainer bracket.
e. Press down firmly on the front of the heat sink until it is seated securely.
f. Rotate the heat-sink release lever to the closed position and hook it
underneath the lock tab.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation” on page 29.
Removing the riser-card assembly
The server comes with one riser-card assembly that contains an HTX riser card that has an HTX adapter slot. Yo u can replace the HTX riser-card assembly with one that has a PCI-X 64-bit 133 MHz connector, or one that has a PCI-Express x16 connector. See the ServerProven list at http://www.ibm.com/servers/eserver/ serverproven/compat/us/ server.
for a list of riser-card assemblies that you can use with the
Retainer bracket
Microprocessor
Chapter 2. Installing optional devices 23
Complete the following steps to remove the riser-card assembly.
Access holes
Release tabs
1. Read the safety information that begins on page v and“Installation guidelines” on page 9.
2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
3. Remove the cover (see “Removing the cover” on page 11).
4. Push the two retention latches on the riser-card assembly toward the second microprocessor slot; then, grasp the assembly at the rear and side edges and lift it to remove it from the server. Place the riser-card assembly on a flat, static-protective surface.
24 IBM System x3655 Type 7985: Installation Guide
Installing the riser-card assembly
To install the riser-card assembly, complete the following steps:
Access holes
Release tabs
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. Make sure that the server and all peripheral devices are turned off, and that the power cords and all external cables are disconnected.
3. Reinstall the Remote Supervisor Adapter II SlimLine if you removed it.
4. Reinstall any adapters and reconnect any cables you might have removed in other procedures.
5. Carefully align the riser-card assembly with the retention latches, the guides on the rear of the server, and the riser-card connector on the system board; then, press down on the assembly. Make sure that the riser-card assembly is fully seated in the riser-card connector on the system board.
If you have other devices to install, do so now. Otherwise, go to “Completing the installation” on page 29.
Chapter 2. Installing optional devices 25
Installing an adapter
Expansion slot 1
Expansion slot cover
Low-profile PCI Express adapter
Riser-card assembly
Expansion slot cover
Adapter
The following illustration shows the location of the PCI expansion slots.
PCI slot 2
PCI slot 1
PCI slot 4
PCI slot 3
The following notes describe the types of adapters that the server supports and other information that you must consider when installing an adapter:
v Yo u can install only low-profile adapters in PCI slots 2 and 3 on the system
board.
v The server comes with one riser-card assembly that contains an HTX riser card
that has an HTX connector. Yo u can replace the HTX riser card assembly with one that has a PCI-Express x16 connector or one that has a PCI-X 64-bit, 133 MHz connector.
v Yo u can install a standard full-length HTX, PCI Express, or PCI-X adapter in slot
1 on the riser-card assembly.
v The optional Remote Supervisor Adapter II SlimLine is installed on the riser card.
To install a Remote Supervisor Adapter II SlimLine, see “Installing the Remote Supervisor Adapter II SlimLine” on page 28.
v Your server supports only 3.3 V and universal PCI adapters.
26 IBM System x3655 Type 7985: Installation Guide
v The PCI bus configuration is as follows:
Non-hot-plug, full-length PCI Express x16 (x16 lanes) or PCI-X 64 bit, 133
MHz, slot 1
Non-hot-plug, low profile PCI Express x4 (x4 lanes), slot 2
Non-hot-plug, low profile PCI Express x8 (x8 lanes), slots 3 and 4
The system scans devices in the following order, if you have not changed the
v
default boot precedence: integrated Ethernet controllers, integrated SAS controller, and then PCI slots 1, 2, 3, and 4.
riser card
PCI
The following illustration shows the location of the adapter expansion slot on the PCI riser card.
Note: For clarity, the riser-card assembly is shown inverted.
HTX adapter connector
Remote Slimline
Riser card assembly
Adapter II connector
To install an adapter, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. Turn off the server and peripheral devices and disconnect all power cords and external cables; then, remove the cover.
3. Determine which expansion slot you will use for the adapter. If you are installing an adapter in PCI slot 1, remove the riser-card assembly (see “Removing the riser-card assembly” on page 23).
4. Slide the expansion-slot cover out of the PCI low-profile expansion slot or riser-card assembly expansion slot.
5. Install the adapter. The following illustration shows how to install an adapter on the riser-card assembly.
Chapter 2. Installing optional devices 27
Note: For clarity, the riser-card assembly is shown inverted.
Riser card assembly
Adapter
6. Replace the riser card assembly if you removed it to install the adapter (see “Installing the riser-card assembly” on page 25).
7. Perform any configuration tasks that are required for the adapter.
If you have other devices to install, do so now. Otherwise, go to “Completing the installation” on page 29.
Installing the Remote Supervisor Adapter II SlimLine
The optional Remote Supervisor Adapter II SlimLine is installed on the riser card. After the Remote Supervisor Adapter II SlimLine is installed, the systems-management Ethernet port on the rear of the server is active.
Note: Earlier versions of the Remote Supervisor Adapter II SlimLine might not work
in this server. See the ServerProven list at http://www.ibm.com/servers/eserver/ serverproven/compat/us/
For details about installing a Remote Supervisor Adapter II SlimLine, see the documentation that comes with the adapter. The following illustration shows how to install the Remote Supervisor Adapter II SlimLine on the riser-card.
Riser card assembly
To install the Remote Supervisor Adapter II SlimLine, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines” on page 9.
2. Turn off the server and peripheral devices and disconnect all power cords and external cables.
3. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 23).
for the supported Remote Supervisor Adapter II SlimLine.
Riser card
Retainer bracket
Remote Supervisor Adapter II SlimLine
28 IBM System x3655 Type 7985: Installation Guide
4. Turn the Remote Supervisor Adapter II SlimLine so that the connector aligns correctly with the connector on the riser card.
5. Install the end of the adapter without the connector first. Slide the adapter under the tabs; then, slide the holes in the adapter onto the pins on the retainer bracket.
6. Rotate the free end of the adapter down under the tabs and onto the pins on the retainer brackets; then, press the adapter into the connector on the riser card and make sure that all the tabs on the latch brackets secure the adapter in place.
the documentation that comes with the Remote Supervisor Adapter II SlimLine
See for information about installing the firmware and configuring the option. Create a backup copy of the configuration so that if you need to replace the adapter in the future, you can restore the configuration.
Note: When you start the server for the first time after you install the Remote
Supervisor Adapter II SlimLine, the start up process will take several minutes longer than a typical startup.
If you have other devices to install, do so now. Otherwise, go to “Completing the installation.”
Replacing the ServeRAID SAS Controller
The server comes with a ServeRAID-8k-l SAS Controller installed. To replace the ServeRAID-8k-l SAS Controller or install a ServeRAID-8k SAS Controller, see the instructions in the User’s Guide on the IBM System x Documentation CD.
Installing an optional tape drive
To install an optional tape drive in the server, see the instuctions in the User’s Guide on the IBM System x Documentation CD.
Completing the installation
To complete the installation, complete the following steps:
1. If you removed the air baffle, install the air baffle (see “Installing the air baffle” on page 13).
2. If you removed the riser-card assembly, install the riser-card assembly (see “Installing the riser-card assembly” on page 25).
3. Install the cover. See “Installing the cover” on page 30 for more information.
4. Install the server in the rack cabinet. See the Rack Installation Instructions that come with the server for detailed information about how to install the server in a rack cabinet.
Attention:
v Install the server only in a rack cabinet that has perforated doors.
v Do not leave open space above or below an installed server in your rack
cabinet. To help prevent damage to server components, always install a filler panel to cover the open space and to help ensure proper air circulation. See the documentation that comes with the rack cabinet for more information.
Connect the cables and power cords. See “Connecting the cables” on page 30
5. for more information.
Chapter 2. Installing optional devices 29
6. Update the server configuration. See “Updating the server configuration” on page 31 for more information.
Installing the cover
To install the cover, complete the following steps.
Cover-release latch
1. Place the cover-release latch in the open (up) position.
2. Insert the bottom tabs of the top cover into the matching slots in the server chassis.
3. Press down on the cover-release latch to lock the cover in place.
4. Slide the server into the rack.
Connecting the cables
The following illustrations show the locations of the input and output connectors on the front and rear of the server.
Front view
USB 5 connector
Rear view
USB 6 connector
Video connector
30 IBM System x3655 Type 7985: Installation Guide
Power cord connector
Optional external SAS connector
You must turn off the server before connecting or disconnecting cables from the server.
See the documentation that comes with any external devices for additional cabling instructions. It might be easier for you to route cables before you connect the devices to the server.
Cable identifiers are printed on the cables that come with the server and optional devices. Use these identifiers to connect the cables to the correct connectors.
Updating the server configuration
When you start the server for the first time after you add or remove an optional devices, you might receive a message that the configuration has changed. The Configuration/Setup Utility program starts automatically so that you can save the new configuration settings. For more information, see Chapter 4, “Configuring the server,” on page 39.
Systems-management Ethernet connector
Serial connector
Video connector
Ethernet 2 connector
Ethernet 1 connector
USB 4 connector
USB 3 connector
USB 1/USB 2 connectors
Some optional devices have device drivers that you must install. See the documentation that comes with each option for information about installing device drivers.
If you have installed or removed a hard disk drive, see “Using the ServeRAID configuration programs” on page 40 for information about reconfiguring the disk arrays.
If you have installed a Remote Supervisor Adapter SlimLine to manage the server remotely, see the Remote Supervisor Adapter User’s Guide, which comes with the adapter, for information about setting up, configuring, and using the adapter.
For information about configuring the integrated Gigabit Ethernet controllers, see the User’s Guide.
Chapter 2. Installing optional devices 31
32 IBM System x3655 Type 7985: Installation Guide
Chapter 3. Server controls, LEDs, and power
This section describes the controls and light-emitting diodes (LEDs) and how to turn the server on and off.
Front view
The following illustration shows the controls, light-emitting diodes (LEDs), and connectors on the front of the 3.5-inch model server.
Operator information panel
USB 5 connector
USB 6 connector
Video connector
Hard disk drive activity LED (green)
Hard disk drive status LED (amber)
CD/DVD eject button
CD/DVD drive activity LED
Rack release latch Rack release latch
The following illustration shows the controls, light-emitting diodes (LEDs), and connectors on the front of the 2.5-inch model server.
Operator information panel
USB 5 connector
USB 6 connector
Video connector
CD/DVD eject button
CD/DVD drive activity LED
Rack release latch Rack release latch
Tape drive bay
Hard disk drive activity LED (green)
Hard disk drive status LED (amber)
Operator information panel: This panel contains controls, LEDs, and connectors.
The following illustration shows the controls, LEDs, and connectors on the operator information panel.
© Copyright IBM Corp. 2007 33
Power-on LED
Power-control button
Hard disk drive activity LED
System locator LED
Information LED
System-error LED
Release latch
The following controls, LEDs, and connectors are on the operator information panel:
v Power-control button: Press this button to turn the server on and off manually.
A power-control-button shield comes installed on the server to prevent the server from being turned off accidentally.
Power-on LED: When this LED is lit and not flashing, it indicates that the server
v
is turned on. When this LED is flashing, it indicates that the server is turned off and still connected to an ac power source. When this LED is off, it indicates that ac power is not present, or the power supply or the LED itself has failed.
Note: If this LED is off, it does not mean that there is no electrical power in the
server. The LED might be burned out. To remove all electrical power from the server, you must disconnect the power cord from the electrical outlet.
v Hard disk drive activity LED: when this LED is flashing, it indicates that a hard
disk drive is in use.
v System-locator LED: Use this LED to visually locate the server among other
servers. Yo u can use IBM Director to light this LED remotely.
v Information LED: When this LED is lit, it indicates that a noncritical event has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the error.
v System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the error.
v Release latch: Slide this latch to the left to access the light path diagnostics
panel.
connectors: Connect a USB device, such as USB mouse, keyboard, or other
USB
USB device, to either of these connectors.
Video connector: Connect a monitor to this connector.
Hard disk drive activity LED: On some server models, each hot-swap hard disk
drive has an activity LED. When this LED is flashing, it indicates that the drive is in use.
Hard disk drive status LED: On some server models, each hot-swap hard disk
drive has a status LED. When this LED is lit, it indicates that the drive has failed. When this LED is flashing slowly (one flash per second), it indicates that the drive is being rebuilt as part of a RAID configuration. When the LED is flashing rapidly (three flashes per second), it indicates that the controller is identifying the drive.
CD/DVD-eject button: Press this button to release a CD or DVD from the
CD-RW/DVD drive.
34 IBM System x3655 Type 7985: Installation Guide
Rear view
CD/DVD drive activity LED: When this LED is lit, it indicates that the CD-RW/DVD
drive is in use.
Rack release latches: Press these latches to release the server from the rack.
The following illustration shows the connectors and LEDs on the rear of the server.
DC power LED
AC power LED
Power cord connector
Optional External SAS connector
Systems-management Ethernet connector
Ethernet activity LEDs
Ethernet link LEDs
Power supply 1
System-locator LED
Serial connector
Power-on LED
System-error LED
Video connector
Ethernet 1 connector
USB 4 connector
Ethernet 2 connector
USB 3 connector
USB 1/USB 2 connectors
Power-cord connector: Connect the power cord to this connector.
AC power LED: Each hot-swap power supply has an ac power LED and a dc
power LED. When the ac power LED is lit, it indicates that sufficient power is coming into the power supply through the power cord. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the
Problem Determination and Service Guide on the IBM System x Documentation
CD.
DC power LED: Each hot-swap power supply has a dc power LED and an ac
power LED. When the dc power LED is lit, it indicates that the power supply is supplying adequate DC power to the system. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Problem
Determination and Service Guide on the IBM System x Documentation CD.
Optional external SAS connector: Connect a serial-attached SCSI (SAS) device
to this connector.
Systems-management Ethernet connector: Use this connector to connect the
server to a network for systems-management information control. This connector is active only if you have installed a Remote Supervisor Adapter II SlimLine, and it is used only by the Remote Supervisor Adapter II SlimLine.
Ethernet activity LEDs: When these LEDs are lit, they indicate that the server is
transmitting to or receiving signals from the Ethernet LAN that is connected to the Ethernet port.
Ethernet link LEDs: When these LEDs are lit, they indicate that there is an active
link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for the Ethernet port.
Chapter 3. Server controls, LEDs, and power 35
Ethernet connectors: Use either of these connectors to connect the server to a
network.
USB connectors: Connect a USB device, such as USB mouse, keyboard, or other
USB device, to any of these connectors.
Video connector: Connect a monitor to this connector.
System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the error.
System-locator LED: Use this LED to visually locate the server among other
servers. Yo u can use IBM Director to light this LED remotely.
Power-on LED: When this LED is lit and not flashing, it indicates that the server is
turned on. When this LED is flashing, it indicates that the server is turned off and still connected to an ac power source. When this LED is off, it indicates that ac power is not present, or the power supply or the LED itself has failed.
Serial connector: Connect a 9-pin serial device to this connector. The serial port is
shared with the baseboard management controller (BMC). The BMC can take control of the shared serial port to perform text console redirection and to redirect serial traffic using Serial over LAN (SOL).
Server power features
When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic except for the service processor (the baseboard management controller or optional Remote Supervisor Adapter II SlimLine) is shut down; however, the server can respond to requests from the service processor, such as a remote request to turn on the server. The power-on LED flashes to indicate that the server is connected to ac power but is not turned on.
Turning on the server
Approximately 5 seconds after the server is connected to ac power, the power-control button becomes active, and one or more fans might start running to provide cooling while the server is connected to power. Yo u can turn on the server and start the operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
v If a power failure occurs while the server is turned on, the server will restart
automatically when power is restored.
v If your operating system supports the Wake on LAN feature, the Wake on LAN
feature can turn on the server.
When 4 GB or more of memory (physical or logical) is installed, some
Note:
memory is reserved for various system resources and is unavailable to the operating system. The amount of memory that is reserved for system resources depends on the operating system, the configuration of the server, and the configured PCI options.
36 IBM System x3655 Type 7985: Installation Guide
Turning off the server
When you turn off the server and leave it connected to ac power, the server can respond to requests from the service processor, such as a remote request to turn on the server. While the server remains connected to ac power, one or more fans might continue to run. To remove all power from the server, you must disconnect it from the power source.
Some operating systems require an orderly shutdown before you turn off the server. See your operating-system documentation for information about shutting down the operating system.
Statement 5:
CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2
1
The server can be turned off in any of the following ways:
v Yo u can turn off the server from the operating system, if your operating system
supports this feature. After an orderly shutdown of the operating system, the server will be turned off automatically.
v Yo u can press the power-control button to start an orderly shutdown of the
operating system and turn off the server, if your operating system supports this feature.
v If the operating system stops functioning, you can press and hold the
power-control button for more than 4 seconds to turn off the server.
v The service processor can turn off the server as an automatic response to a
critical system failure.
v Yo u can turn off the server through a request from the service processor.
Chapter 3. Server controls, LEDs, and power 37
38 IBM System x3655 Type 7985: Installation Guide
Chapter 4. Configuring the server
The ServerGuide Setup and Installation CD provides software setup tools and installation tools that are specifically designed for your IBM server. Use this CD during the initial installation of the server to configure basic hardware features and to simplify the operating-system installation.
In addition to the ServerGuide Setup and Installation CD, you can use the following configuration programs to customize the server hardware:
v Configuration/Setup Utility program
v Baseboard management controller utility programs
v RAID configuration programs
ServeRAID Configuration Utility program
ServeRAID Manager
more information about these programs, see “Configuring the server” in the
For
User’s Guide on the IBM System x Documentation CD.
Using the ServerGuide Setup and Installation CD
The ServerGuide Setup and Installation CD provides programs to detect the server model and installed optional hardware devices, configure the server hardware, provide device drivers, and help you install the operating system. For information about the supported operating-system versions, see the label on the CD. If the
ServerGuide Setup and Installation CD did not come with the server, you can
download the latest version from http://www.ibm.com/pc/qtechinfo/MIGR­4ZKPPT.HTML
To start the ServerGuide Setup and Installation CD, complete the following steps:
1. Insert the CD, and restart the server. If the CD does not start, see “ServerGuide problems” on page 72.
2. Follow the instructions on the screen to:
a. Select your language.
b. Select your keyboard layout and country.
c. View the overview to learn about ServerGuide features.
d. View the readme file to review installation tips about your operating system
and adapter.
e. Start the setup and hardware configuration programs.
f. Start the operating-system installation. You will need your operating-system
CD.
Using the Configuration/Setup Utility program
The Configuration/Setup Utility program is part of the BIOS. You can use it to perform the following tasks:
v View configuration information
v View and change assignments for devices and I/O ports
v Set the date and time
v Set and change the power-on passwords
© Copyright IBM Corp. 2007 39
v Set the startup characteristics of the server and the order of startup devices
(startup-drive sequence)
v Set and change settings for advanced hardware features
v View and clear the error log
v Change interrupt request (IRQ) settings
v Enable USB legacy keyboard and mouse support
v Resolve configuration conflicts
start the Configuration/Setup Utility program, complete the following steps:
To
1. Turn on the server.
2. When the prompt Press F1 for Configuration/Setup appears, press F1. If you
have set both a power-on password and an administrator password, you must type the administrator password to access the full Configuration/Setup Utility menu. If you do not type the administrator password, a limited Configuration/Setup Utility menu will appear.
3. Select settings to view or change.
Using the ServeRAID configuration programs
Use the IBM ServeRAID Configuration Utility program and ServeRAID Manager to configure and manage redundant array of independent disks (RAID) arrays. Be sure to use these programs as described in this document.
v Use the IBM ServeRAID Configuration Utility program to:
Perform a low-level format on a hard disk drive
View or change IDs for attached devices
Set protocol parameters on hard disk drives
v Use ServeRAID Manager to:
Configure arrays
View the RAID configuration and associated devices
Monitor operation of the RAID controllers
Consider
the following information when using the IBM ServeRAID Configuration
Utility program and ServeRAID Manager to configure and manage arrays:
v The ServeRAID-8k-l SAS controller that comes with the server supports only
RAID level-0, level-1, and level-10. You can replace the controller with a ServeRAID-8k SAS controller that supports additional RAID levels.
v Hard disk drive capacities affect how you create arrays. The drives in an array
can have different capacities, but the ServeRAID controller treats them as if they all have the capacity of the smallest hard disk drive.
v To help ensure signal quality, do not use drives with different speeds and data
rates in the array.
v To update the firmware and BIOS code for an optional ServeRAID SAS
controller, you must use the IBM ServeRAID CD that comes with the ServeRAID option.
Using the IBM ServeRAID Configuration Utility program
Use the IBM ServeRAID Configuration Utility Manager to perform the following tasks:
v Configure a redundant array of independent disks (RAID) array
v View or change the RAID configuration and associated devices
40 IBM System x3655 Type 7985: Installation Guide
Starting the IBM ServeRAID Configuration Utility program
To start the IBM ServeRAID Configuration program, complete the following steps:
1. Turn on the server.
2. When the prompt <<<Press <CTRL><A> for IBM ServeRAID Configuration
Utility>>> appears, press Ctrl+A. If you have set an administrator password,
you are prompted to type the password.
3. To select a choice from the menu, use the arrow keys.
4. Use the arrow keys to select the channel for which you want to change settings.
5. To change the settings of the selected items, follow the instructions on the screen. Be sure to press Enter to save your changes.
IBM ServeRAID Configuration Utility menu choices
The following choices are on the IBM ServeRAID Configuration Utility menu:
v Array Configuration Utility
Select this choice to create, manage, or delete arrays, or to initialize drives.
v SerialSelect Utility
Select this choice to configure the controller interface definitions or to configure the physical transfer and the address of the selected drive.
v Disk Utilities
Select this choice to format a disk or verify the disk media. Select a device from the list and read the instructions on the screen carefully before making a selection.
Using ServeRAID Manager
Use ServeRAID Manager, which is on the IBM ServeRAID Support CD, to:
v Configure a redundant array of independent disks (RAID) array
v Erase all data from a hard disk drive and return the disk to the factory-default
settings
v View the RAID configuration and associated devices
v Monitor the operation of the RAID controller
To perform some tasks, you can run ServeRAID Manager as an installed program. However, to configure the RAID controller and perform an initial RAID configuration on the server, you must run ServeRAID Manager in Startable CD mode, as described in the instructions in this section. If you install a different type of RAID adapter in the server, follow the instructions in the documentation that comes with the adapter to view or change SCSI settings for attached devices.
See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID technology and instructions for using ServeRAID Manager to configure the RAID controller. Additional information about ServeRAID Manager is also available from the Help menu. For information about a specific object in the ServeRAID Manager tree, select the object and click Actions-->Hints
and tips.
Configuring the RAID controller
By running ServeRAID Manager in Startable CD mode, you can configure the controller before you install the operating system. The information in this section assumes that you are running ServeRAID Manager in Startable CD mode.
Chapter 4. Configuring the server 41
To run ServeRAID Manager in Startable CD mode, turn on the server; then, insert the CD into the CD-RW/DVD drive. If ServeRAID Manager detects an unconfigured controller and Ready drives, the Configuration wizard starts.
In the Configuration wizard, you can select express configuration or custom configuration. Express configuration automatically configures the controller by grouping the first two physical drives in the ServeRAID Manager tree into an array and creating a RAID level-1 logical drive. If you select custom configuration, you can select the two physical drives that you want to group into an array and create a hot-spare drive.
Using express configuration: To use express configuration, complete the
following steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click Express configuration.
3. Click Next.
4. In the “Configuration summary” review the information. To change the
configuration, click Modify arrays.
5. Click Apply; when asked if you want to apply the new configuration, click Yes.
The configuration information is saved in the controller and in the physical drives.
6. Exit from ServeRAID Manager and remove the CD from the CD-RW/DVD drive.
7. Restart the server.
custom configuration: To use custom configuration, complete the
Using
following steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click Custom configuration.
3. Click Next.
4. In the “Create arrays” window, from the list of Ready drives, select the drives that you want to group into the array.
5. Click the (Add selected drives) icon to add the drives to the array.
6. If you want to configure a hot-spare drive, complete the following steps: a. Click the Spares tab.
b. Select the physical drive that you want to designate as the hot-spare drive,
and click the (Add selected drives) icon.
7. Click Next.
8. Review the information in the “Configuration summary” window. To change the configuration, click Back.
9. Click Apply; when you are asked whether you want to apply the new configuration, click Yes. The configuration information is saved in the controller and in the physical drives.
10. Exit from ServeRAID Manager and remove the CD from the CD drive.
11. Restart the server.
Viewing the configuration
You can use ServeRAID Manager to view information about RAID controllers and the RAID subsystem (such as arrays, logical drives, hot-spare drives, and physical drives). When you click an object in the ServeRAID Manager tree, information about that object appears in the right pane. To display a list of available actions for an object, click the object and click Actions.
42 IBM System x3655 Type 7985: Installation Guide
Using the baseboard management controller
The baseboard management controller provides basic environmental monitoring for the server. If an environmental condition exceeds a threshold or if system components fail, the baseboard management controller lights LEDs to help you diagnose the problem and also records the error in the BMC system event log.
The baseboard management controller also provides the following remote server management capabilities through the OSA SMBridge management utility program:
v Command-line interface (IPMI Shell)
The command-line interface provides direct access to server management functions through the IPMI protocol. Use the command-line interface to issue commands to control the server power, view system information, and identify the server. You can also save one or more commands as a text file and run the file as a script.
v Serial over LAN
Establish a Serial over LAN (SOL) connection to manage servers from a remote location. Yo u can remotely view and change the BIOS settings, restart the server, identify the server, and perform other management functions. Any standard Telenet client application can access the SOL connection.
Important:
The server Ethernet ports are set to DHCP by default. In order to find
your BMC on an existing network, you will need to identify the server by the default hostname. The default hostname for each server is the last 8 characters of the BMC MAC address. The BMC MAC address can be found in the setup utility, on a label on the system board, and on a tag hanging from the front of the server. Once you have deployed your server, make sure that you remove the BMC MAC address tag from the front of the server so that it does not impede airflow through the front of the server.
Enabling and configuring SOL using the OSA SMBridge management utility program
To enable and configure the server for SOL by using the OSA SMBridge management utility program, you must update and configure the BIOS code and update and configure the baseboard management controller (BMC) firmware; update and configure the Ethernet controller firmware; and enable the operating system for an SOL connection.
BIOS update and configuration
To update and configure the BIOS code to enable SOL, complete the following steps:
1. Update the BIOS code:
a. Download the latest version of the BIOS code from http://www.ibm.com/
support/.
b. Update the BIOS code, following the instructions that come with the update
file that you downloaded.
Update the BMC firmware:
2.
a. Download the latest version of the BMC firmware from http://www.ibm.com/
support/.
b. Update the BMC firmware, following the instructions that come with the
update file that you downloaded.
Chapter 4. Configuring the server 43
3. Configure the BIOS settings:
a. When you are prompted to start the Configuration/Setup Utility program,
restart the server and press F1.
b. Select Devices and I/O Ports; then, make sure that the values are set as
follows:
v Serial Port A: Auto-configure v Serial Port B: Auto-configure
Select Remote Console Redirection; then, make sure that the values are
c.
set as follows:
v Remote Console Active: Enabled v Remote Console COM Port: COM 1 v Remote Console Baud Rate: 19200 or higher v Remote Console Data Bits: 8 v Remote Console Parity: None v Remote Console Stop Bits: 1 v Remote Console Text Emulation: ANSI v Remote Console Keyboard Emulation: ANSI v Remote Console Active After Boot: Enabled v Remote Console Flow Control: Hardware
Press Esc twice to exit the Remote Console Redirection and Devices and
d.
I/O Ports sections of the Configuration/Setup Utility program.
e. Select Advanced Setup; then, select Baseboard Management Controller
(BMC) Settings.
f. Set BMC Serial Port Access Mode to Dedicated. g. Press Esc twice to exit the Baseboard Management Controller (BMC)
Settings and Advanced Setup sections of the Configuration/Setup Utility
program.
h. Select Save Settings; then, press Enter.
i. Press Enter to confirm. j. Select Exit Setup; then, press Enter. k. Make sure that Yes, exit the Setup Utility is selected; then, press Enter.
Linux configuration
For SOL operation on the server, you must configure the Linux® operating system to expose the Linux initialization (booting) process. This enables users to log in to the Linux console through an SOL session and directs Linux output to the serial console. See the documentation for your specific Linux operating-system type for information and instructions.
Use one of the following procedures to enable SOL sessions for your Linux operating system. You must be logged in as a root user to perform these procedures.
Red Hat Enterprise Linux ES 4 configuration:
Note: This procedure is based on a default installation of Red Hat Enterprise Linux
ES 4. The file names, structures, and commands might be different for other versions of Red Hat Linux.
44 IBM System x3655 Type 7985: Installation Guide
To configure the general Linux parameters for SOL operation when you are using the Red Hat Enterprise Linux ES 4 operating system, complete the following steps.
Note: Hardware flow control prevents character loss during communication over a
serial connection. You must enable it when using a Linux operating system.
1. Add the following line to the end of the # Run gettys in standard runlevels
section of the /etc/inittab file. This enables hardware flow control and enables users to log in through the SOL console.
7:2345:respawn:/sbin/agetty -h ttyS0 19200 vt102
2. Add the following line at the bottom of the /etc/securetty file to enable a user to log in as the root user through the SOL console:
ttyS0
LILO configuration: If you are using LILO, complete the following steps:
1. Modify the /etc/lilo.conf file: a. Add the following text to the end of the first default=linux line
-Monitor
b. Comment out the map=/boot/map line by adding a # at the beginning of this
line.
c. Comment out the message=/boot/message line by adding a # at the beginning
of this line.
d. Add the following line before the first image= line:
# This will allow you to only Monitor the OS boot via SOL
e. Add the following text to the end of the first label=linux line:
-Monitor
f. Add the following line to the first image= section. This enables SOL.
append="console=ttyS0,19200n8 console=tty1"
g. Add the following lines between the two image= sections:
# This will allow you to Interact with the OS boot via SOL
image=/boot/vmlinuz-2.4.9-e.12smp
label=linux-Interact
initrd=/boot/initrd-2.4.9-e.12smp.img
read-only
root=/dev/hda6
append="console=tty1 console=ttyS0,19200n8 "
The following examples show the original content of the /etc/lilo.conf file and the content of this file after modification.
Chapter 4. Configuring the server 45
Original /etc/lilo.conf contents
prompt
timeout=50
default=linux
boot=/dev/hda
map=/boot/map
install=/boot/boot.b
message=/boot/message
linear
image=/boot/vmlinuz-2.4.9-e.12smp
label=linux
initrd=/boot/initrd-2.4.9-e.12smp.img
read-only
root=/dev/hda6
image=/boot/vmlinuz-2.4.9-e.12
label=linux-up
initrd=/boot/initrd-2.4.9-e.12.img
read-only
root=/dev/hda6
46 IBM System x3655 Type 7985: Installation Guide
Modified /etc/lilo.conf contents
prompt
timeout=50
default=linux-Monitor
boot=/dev/hda
#map=/boot/map
install=/boot/boot.b
#message=/boot/message
linear
# This will allow you to only Monitor the OS boot via SOL
image=/boot/vmlinuz-2.4.9-e.12smp
label=linux-Monitor
initrd=/boot/initrd-2.4.9-e.12smp.img
read-only
root=/dev/hda6
append="console=ttyS0,19200n8 console=tty1"
# This will allow you to Interact with the OS boot via SOL
image=/boot/vmlinuz-2.4.9-e.12smp
label=linux-Interact
initrd=/boot/initrd-2.4.9-e.12smp.img
read-only
root=/dev/hda6
append="console=tty1 console=ttyS0,19200n8 "
image=/boot/vmlinuz-2.4.9-e.12
label=linux-up
initrd=/boot/initrd-2.4.9-e.12.img
read-only
root=/dev/hda6
2. Run the lilo command to store and activate the LILO configuration.
When the Linux operating system starts, a LILO boot: prompt is displayed instead of the graphical user interface. Press Ta b at this prompt to install all of the boot options that are listed. To load the operating system in interactive mode, type
linux-Interact and then press Enter.
GRUB configuration: If you are using GRUB, complete the following steps to
modify the /boot/grub/grub.conf file:
1. Comment out the splashimage= line by adding a # at the beginning of this line.
2. Add the following line before the first title= line:
# This will allow you to only Monitor the OS boot via SOL
3. Append the following text to the first title= line:
SOL Monitor
4. Append the following text to the kernel/ line of the first title= section:
console=ttyS0,19200 console=tty1
5. Add the following five lines between the two title= sections:
# This will allow you to Interact with the OS boot via SOL
title Red Hat Linux (2.4.9-e.12smp) SOL Interactive
root (hd0,0)
Chapter 4. Configuring the server 47
kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1
console=ttyS0,19200
initrd /initrd-2.4.9-e.12smp.img
Note: The entry that begins with kernel /vmlinuz is shown with a line break after console=tty1. In your file, the entire entry must all be on one line.
The following examples show the original content of the /boot/grub/grub.conf file and the content of this file after modification.
Original /boot/grub/grub.conf contents
#grub.conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes to this file
# NOTICE: You have a /boot partition. This means that
# all kernel and initrd paths are relative to /boot/, eg.
# root (hd0,0)
# kernel /vmlinuz-version ro root=/dev/hda6
# initrd /initrd-version.img
#boot=/dev/hda
default=0
timeout=10
splashimage=(hd0,0)/grub/splash.xpm.gz
title Red Hat Enterprise Linux ES (2.4.9-e.12smp)
root (hd0,0)
kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6
initrd /initrd-2.4.9-e.12smp.img
title Red Hat Enterprise Linux ES-up (2.4.9-e.12)
root (hd0,0)
kernel /vmlinuz-2.4.9-e.12 ro root=/dev/hda6
initrd /initrd-2.4.9-e.12.img
48 IBM System x3655 Type 7985: Installation Guide
Modified /boot/grub/grub.conf contents
#grub.conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes to this file
# NOTICE: You have a /boot partition. This means that
# all kernel and initrd paths are relative to /boot/, eg.
# root (hd0,0)
# kernel /vmlinuz-version ro root=/dev/hda6
# initrd /initrd-version.img
#boot=/dev/hda
default=0
timeout=10
# splashimage=(hd0,0)/grub/splash.xpm.gz
# This will allow you to only Monitor the OS boot via SOL
title Red Hat Enterprise Linux ES (2.4.9-e.12smp) SOL Monitor
root (hd0,0)
kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=ttyS0,19200 console=tty1
initrd /initrd-2.4.9-e.12smp.img
# This will allow you to Interact with the OS boot via SOL
title Red Hat Linux (2.4.9-e.12smp) SOL Interactive
root (hd0,0)
kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1 console=ttyS0,19200
initrd /initrd-2.4.9-e.12smp.img
title Red Hat Enterprise Linux ES-up (2.4.9-e.12)
root (hd0,0)
kernel /vmlinuz-2.4.9-e.12 ro root=/dev/hda6
initrd /initrd-2.4.9-e.12.img
You must restart the Linux operating system after you complete these procedures for the changes to take effect and to enable SOL.
SUSE SLES 9.0 configuration:
Note: This procedure is based on a default installation of SUSE Linux Enterprise
Server (SLES) 9.0. The file names, structures, and commands might be different for other versions of SUSE LINUX.
To configure the general Linux parameters for SOL operation when using the SLES
9.0 operating system, complete the following steps.
Note: Hardware flow control prevents character loss during communication over a
serial connection. You must enable it when using a Linux operating system.
1. Add the following line to the end of the # getty-programs for the normal
runlevels section of the /etc/inittab file. This enables hardware flow control and
enables users to log in through the SOL console.
7:2345:respawn:/sbin/agetty -h ttyS0 19200 vt102
2. Add the following line after the tty6 line at the bottom of the /etc/securetty file to enable a user to log in as the root user through the SOL console:
ttyS0
Chapter 4. Configuring the server 49
3. Complete the following steps to modify the /boot/grub/menu.lst file:
a. Comment out the gfxmenu line by adding a # in front of the word gfxmenu. b. Add the following line before the first title line:
# This will allow you to only Monitor the OS boot via SOL
c. Append the following text to the first title line:
SOL Monitor
d. Append the following text to the kernel line of the first title section:
console=ttyS1,19200 console=tty0
e. Add the following four lines between the first two title sections:
# This will allow you to Interact with the OS boot via SOL
title linux SOL Interactive
kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791
console=tty1 console=ttyS0,19200
initrd (hd0,1)/boot/initrd
The following examples show the original content of the /boot/grub/menu.lst file and the content of this file after modification.
Original /boot/grub/menu.lst contents Notes
gfxmanu (hd0,1)/boot/message color white/blue black/light-gray default 0 timeout 8
title linux
kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 1 initrd (hd0,1)/boot/initrd
title floppy
root chainloader +1
title failsafe
kernal (hd0,1)/boot/vmlinuz.shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp 1
disableapic maxcpus=0 3
initrd (hd0,1)/boot/initrd.shipped
Note 1: The kernel line is shown with a line break. In your file, the entire entry must all be on one line.
Modified /boot/grub/menu.lst contents Notes
#gfxmanu (hd0,1)/boot/message color white/blue black/light-gray default 0 timeout 8
# This will allow you to only Monitor the OS boot via SOL title linux SOL Monitor
kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=ttyS1,19200 1
console=tty1
initrd (hd0,1)/boot/initrd
# This will allow you to Interact with the OS boot via SOL title linux SOL Interactive
kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=tty1 console=ttyS0,19200 initrd (hd0,1)/boot/initrd
50 IBM System x3655 Type 7985: Installation Guide
Modified /boot/grub/menu.lst contents Notes
title floppy
root chainloader +1
title failsafe
kernel (hd0,1)/boot/vmlinuz.shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp 1
disableapic maxcpus=0 3
initrd (hd0,1)/boot/initrd.shipped
Note 1: The kernel line is shown with a line break. In your file, the entire entry must all be on one line.
You must restart the Linux operating system after completing these procedures for the changes to take effect and to enable SOL.
Microsoft Windows 2003 Standard Edition configuration
Note: This procedure is based on a default installation of the Microsoft Windows
2003 operating system.
To configure the Windows 2003 operating system for SOL operation, complete the following steps. You must be logged in as a user with administrator access to perform this procedure.
1. Complete the following steps to determine which boot entry ID to modify: a. Type bootcfg at a Windows command prompt; then, press Enter to display
the current boot options for your server.
b. In the Boot Entries section, locate the boot entry ID for the section with an
OS friendly name of Windows Server 2003, Standard. Write down the boot entry ID for use in the next step.
To enable the Microsoft Windows Emergency Management System (EMS), at a
2. Windows command prompt, type
bootcfg /EMS ON /PORT COM1 /BAUD 19200 /ID boot_id
where boot_id is the boot entry ID from step 1b; then, press Enter.
3. Complete the following steps to verify that the EMS console is redirected to the COM1 serial port:
a. Type bootcfg at a Windows command prompt; then, press Enter to display
the current boot options for your server.
b. Verify the following changes to the bootcfg settings:
v In the Boot Loader Settings section, make sure that redirect is set to
COM1 and that redirectbaudrate is set to 19200.
v In the Boot Entries section, make sure that the OS Load Options: line
has /redirect appended to the end of it.
The following examples show the original bootcfg program output and the output after modification.
Chapter 4. Configuring the server 51
Original bootcfg program output
Boot Loader Settings
----------------------------
timeout: 30
default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
Boot Entries
----------------
Boot entry ID: 1
OS Friendly Name: Windows Server 2003, Standard
Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
OS Load Options: /fastdetect
Modified bootcfg program output
Boot Loader Settings
----------------------------
timeout: 30
default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
redirect: COM1
redirectbaudrate: 19200
Boot Entries
----------------
Boot entry ID: 1
OS Friendly Name: Windows Server 2003, Standard
Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
OS Load Options: /fastdetect /redirect
You must restart the Windows 2003 operating system after completing this procedure for the changes to take effect and to enable SOL.
Installing the OSA SMBridge management utility program
Important: To obtain maximum benefit from the OSA SMBridge management utility
program, install and load the program before problems occur.
To install the OSA SMBridge management utility program on a server running a Windows operating system, complete the following steps:
1. Go to http://www.ibm.com/support/ and download the utility program and create the OSA BMC Management Utility CD.
2. Insert the OSA BMC Management Utility CD into the drive. The InstallShield wizard starts, and a window similar to that shown in the following illustration opens.
52 IBM System x3655 Type 7985: Installation Guide
3. Follow the prompts to complete the installation.
The installation program prompts you for a TCP/IP port number and an IP address. Specify an IP address, if you want to limit the connection requests that will be accepted by the utility program. To accept connections from any server, type INADDR_ANY as the IP address. Also specify the port number that the utility program will use. These values will be recorded in the smbridge.cfg file for the automatic startup of the utility program.
install the OSA SMBridge management utility program on a server running a
To Linux operating system, complete the following steps. Yo u must be logged in as a root user to perform these procedures.
1. Go to http://www.ibm.com/support/ and download the utility program and create the OSA BMC Management Utility CD.
2. Insert the OSA BMC Management Utility CD into the drive.
3. Type mount/mnt/cdrom.
4. Locate the directory where the installation RPM package is located and type cd/mnt/cdrom.
5. Type the following command to run the RPM package and start the installation:
rpm -ivh smbrodge-2.0-xx6.rpm
Where xx is the release level being installed.
6. Follow the prompts to complete the installation. When the installation is complete, the utility copies files to the following directories:
/etc/init.d/SMBridge /etc/smbridge.cfg /usr/sbin/smbridged /var/log/smbridge/Liscense.txt /var/log/smbridge/Readme.txt
Chapter 4. Configuring the server 53
The utility starts automatically when the server is started. You can also locate the /ect/init.d directory to start the utility and use the following commands to manage the utility:
smbridge status smbridge start smbridge stop smbridge restart
Using the baseboard management controller utility programs
Use the baseboard management controller utility programs to configure the baseboard management controller, download firmware updates and SDR/FRU updates, and remotely manage a network.
Using the baseboard management controller configuration utility program
Use the baseboard management controller configuration utility program to view or change the baseboard management controller configuration settings. Yo u can also use the utility program to save the configuration to a file for use on multiple servers.
Note: Yo u must attach an optional USB diskette drive to the server to run this
program.
To start the baseboard management controller configuration utility program, complete the following steps:
1. Insert the configuration utility diskette into the diskette drive and restart the server.
2. From a command-line prompt, type bmc_cfg and press Enter.
3. Follow the instructions on the screen.
Using the baseboard management controller firmware update utility program
Use the baseboard management controller firmware update utility program to download and apply a baseboard management controller firmware update and a SDR/FRU update. The firmware update utility program updates the baseboard management controller firmware and SDR/FRU data only and does not affect any device drivers.
Note: To ensure proper server operation, be sure to update the server baseboard
management controller firmware before you update the BIOS code.
To update the firmware, if the Linux or Windows operating-system update package is available from the World Wide Web and you have obtained the applicable update package, follow the instructions that come with the update package.
Using the OSA SMBridge management utility program
Use the OSA SMBridge management utility program to remotely manage and configure a network. The utility program provides the following remote management capabilities:
v CLI (command-line interface) mode
Use CLI mode to remotely perform power-management and system identification control functions over a LAN or serial port interface from a command-line interface. Use CLI mode also to remotely view the System Event/Error log.
54 IBM System x3655 Type 7985: Installation Guide
Use the following commands in CLI mode: identify
Control the system-locator LED on the front of the server.
power
Turn the server on and off remotely.
sel
Perform operations with the BMC system event log.
sysinfo
Display general system information that is related to the server and the baseboard management controller.
Serial over LAN
v
Use the Serial over LAN capability to remotely perform control and management functions over a Serial over LAN (SOL) network. You can also use SOL to remotely view and change the server BIOS settings.
At a command prompt, type telenet localhost 623 to access the SOL network. Type help at the smbridge> prompt for more information.
Use the following commands in an SOL session: connect
Connect to the LAN. Type connect -ip ip_address -u username -p password.
identify
Control the system-locator LED on the front of the server.
power
Turn the server on and off remotely.
reboot
Force the server to restart.
sel get
Display the BMC system event log.
sol
Configure the SOL function.
sysinfo
Display system information that is related to the server and the globally unique identifier (GUID).
Chapter 4. Configuring the server 55
56 IBM System x3655 Type 7985: Installation Guide
Chapter 5. Solving problems
This chapter provides basic troubleshooting information to help you solve some common problems that might occur while you are setting up the server.
If you cannot diagnose and correct problems using the information in this chapter, see Appendix A, “Getting help and technical assistance,” on page 77, the Problem
Determination and Service Guide on the IBM System x Documentation CD, and the
“Server Support” flowchart in the front of this document.
Diagnostic tools overview
The following tools are available to help you diagnose and solve hardware-related problems:
v POST beep codes
The power-on self-test beep codes indicate the detection of a problem.
One beep indicates successful completion of POST, with no errors.
More than one beep indicates that POST detected a problem. Error messages
are displayed also if POST detects a hardware-configuration problem.
See “POST beep codes” and the Problem Determination and Service Guide on the IBM System x Documentation CD for more information.
Troubleshooting tables
v
These tables list problem symptoms and actions to correct the problems. See “Troubleshooting tables” on page 61 for more information.
v Diagnostic programs and error messages
The system diagnostic programs are provided in ROM. These programs test the major components of the server. See the Problem Determination and Service
Guide on the IBM System x Documentation CD for more information.
v Light path diagnostics
Use light path diagnostics to diagnose system errors quickly. See “Light path diagnostics” on page 73 for more information.
POST beep codes
POST emits one beep to signal successful completion. If POST detects a problem during startup, other beep codes might occur. Use the following beep code descriptions to help diagnose and solve problems that are detected during startup.
Note: See the Problem Determination and Service Guide on the IBM System x Documentation CD for more information about the POST beep codes.
beep
One
Repeating long beeps
One long beep and two short beeps
© Copyright IBM Corp. 2007 57
POST was completed successfully without finding any errors.
A memory error has occurred. Make sure that all DIMMs are correctly installed.
A video error has occurred, and the BIOS cannot initialize the monitor screen to display additional information.
Other beep codes
POST error codes
The following table provides an abbreviated list of the error codes that might appear during POST. See the Problem Determination and Service Guide on the IBM
System x Documentation CD for more information about the POST error codes. To
check for updated technical information, go to http://www.ibm.com/servers/eserver/ support/xseries/index.html, select System x3655 and click Go; then, click the Install and use tab, and click Product documentation.
See the Problem Determination and Service Guide on the IBM System x
Documentation CD for information about other beep codes.
Table 3. Abbreviated list of POST error messages
POST message
101, 102 Tick timer internal
151 Real-time clock error.
Failing device or problem found Suggested action
interrupt, internal timer channel 2
1. Reseat the system board.
2. (Trained service technician only) Replace the system board.
1. Reseat the battery.
2. Replace the following components one at a time, in the order shown, restarting the server each time:
a. System-board battery
b. (Trained service technician only) System
board
162 Device configuration
error.
1. Run the Configuration/Setup Utility program, select Load Default Settings, and save the settings.
2. Reseat the following components one at a time, in the order shown, restarting the server each time:
a. Battery
b. Failing device
c. (Trained service technician only) System
board
163 Real-time clock error.
1. Run the Configuration/Setup Utility program, select Load Default Settings, make sure the date and time are correct, and save the settings.
2. Reseat the battery.
3. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Battery
b. (Trained service technician only) System
board
58 IBM System x3655 Type 7985: Installation Guide
Table 3. Abbreviated list of POST error messages (continued)
POST message
289 A DIMM has been
Failing device or problem found Suggested action
disabled by the user or by the system.
1. If the DIMM was disabled by the user, run the Configuration/Setup Utility program and enable the DIMM.
2. Reseat the disabled DIMM.
3. (Trained service technician) Reseat the microprocessor.
4. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Disabled DIMM
b. Microprocessor
c. (Trained service technician only) System
board
301 Keyboard or keyboard
controller error.
1. If you have installed a USB keyboard, run the Configuration/Setup Utility program and enable keyboardless operation to prevent the POST error message 301 from being displayed during startup.
2. Reseat the keyboard.
3. Replace the following components one at at time, in the order shown, restarting the server each time:
a. Keyboard
b. (Trained service technician only) System
board
303 Keyboard controller
error.
00019xxx Microprocessor x is
not functioning or failed the built-in self-test.
(Trained service technician only) Replace the system board.
1. (Trained service technician only) Reseat microprocessor x.
2. Replace the following components one at a time, in the order shown, restarting the server each time:
a. (Trained service technician) Microprocessor
x
b. (Trained service technician only) System
board
Chapter 5. Solving problems 59
Table 3. Abbreviated list of POST error messages (continued)
POST message
00180xxx A PCI adapter has
Failing device or problem found Suggested action
requested memory resources that are not available.
1. See http:\\www.ibm.com/servers/eserver/ support/xseries/index.html MIGR-61663 for additional information on the error code.
and search for
2. Verify that the BIOS code is at the latest level.
3. Run the Configuration/Setup Utility program to verify that the interrupt resource settings are correct.
4. Reseat the failing adapter (if installed).
5. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Failing adapter
b. (Trained service technician only) System
board
012980xx
012981xx
19990305 An operating system
No update data for microprocessor xx.
was not found.
1. Update the BIOS code.
2. Reseat microprocessor xx.
3. Replace microprocessor xx.
1. Make sure that a bootable operating system is installed.
2. Run the hard disk drive diagnostic test.
3. Reseat the had disk drive.
4. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Hard disk drive
b. (Trained service technician only) System
board
60 IBM System x3655 Type 7985: Installation Guide
Troubleshooting tables
Use the troubleshooting tables to find solutions to problems that have identifiable symptoms. See the Problem Determination and Service Guide on the IBM System x
Documentation CD for more detailed troubleshooting information. If you cannot find
the problem in these tables, run the diagnostic programs (see “Running the diagnostic programs” in the Problem Determination and Service Guide).
If you have just added new software or a new optional device and the server is not working, complete the following steps before using the troubleshooting tables:
1. Check the light path diagnostics LEDs on the operator information panel (see “Light path diagnostics” on page 73).
2. Remove the software or device that you just added.
3. Run the diagnostic tests to determine whether the server is running correctly.
4. Reinstall the new software or new device.
CD or DVD drive problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The CD or DVD drive is not recognized.
A CD-RW/DVD is not working correctly.
The CD-RW/DVD drive tray is not working.
1. Make sure that:
v The IDE channel to which the CD-RW/DVD drive is attached (primary) is
enabled in the Configuration/Setup Utility program.
v All cables and jumpers are installed correctly.
v The correct device driver is installed for the CD-RW/DVD drive.
Run the CD-RW/DVD drive diagnostic programs.
2.
3. Reseat the following components:
a. CD-RW/DVD drive
b. IDE/Ultrabay Enhanced (UBE) interposer card cable
4.
Replace the components listed in step 3 one at a time, in the order shown,
restarting the server each time.
1. Clean the CD or DVD.
2. Run the CD-RW/DVD drive diagnostic programs.
3. Reseat the CD-RW/DVD drive.
4. Replace the CD-RW/DVD drive.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release opening.
3. Reseat the CD-RW/DVD drive.
4. Replace the CD-RW/DVD drive.
Chapter 5. Solving problems 61
General problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A cover lock is broken, an LED is not working, or a similar
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a trained service technician.
problem has occurred.
Hard disk drive problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
Not all drives are recognized by the hard disk drive diagnostic test (the Fixed Disk test).
The server stops responding during the hard disk drive diagnostic test.
A hard disk drive was not detected while the operating system was being started.
A hard disk drive passes the diagnostic Fixed Disk Test but the problem remains.
Remove the drive that is indicated by the diagnostic tests; then, run the hard disk drive diagnostic test again. If the remaining drives are recognized, replace the drive that you removed with a new one.
Remove the hard disk drive that was being tested when the server stopped responding, and run the diagnostic test again. If the hard disk drive diagnostic test runs successfully, replace the drive that you removed with a new one.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic tests again.
Run the diagnostic SCSI Fixed Disk Test (see“Running the diagnostic programs” in the Problem Determination and Service Guide).
62 IBM System x3655 Type 7985: Installation Guide
Intermittent problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A problem occurs only occasionally and is difficult to diagnose.
1. Make sure that:
v All cables and cords are connected securely to the rear of the server and
attached devices.
v When the server is turned on, air is flowing from the fan grille. If there is no
airflow, the fan is not working. This can cause the server to overheat and shut down.
Check the system-error log or BMC log (see “Error Logs” in the Problem
2. Determination and Service Guide).
Keyboard, mouse, or pointing-device problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
All or some keys on the keyboard do not work.
1. If you are using a USB keyboard, run the Configuration/Setup Utility program and enable keyboardless operation to prevent the POST error message 301 from being displayed during startup.
2. Make sure that:
v The keyboard cable is securely connected.
v The server and the monitor are turned on.
If you are using a USB keyboard and it is connected to a USB hub, disconnect
3. the keyboard from the hub and connect it directly to the server.
4. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Keyboard
b. (Trained service technician only) System board
Chapter 5. Solving problems 63
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The mouse or pointing device does not work.
1. Make sure that:
v The mouse or pointing-device cable is securely connected to the server.
v The mouse or pointing-device device drivers are installed correctly.
v The server and the monitor are turned on.
v The mouse option is enabled in the Configuration/Setup Utility program.
If a USB hub is in use, disconnect the USB device from the hub and connect it
2. directly to the server.
3. Reseat the mouse or pointing device cable.
4. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Mouse or pointing device
b. (Trained service technician only) System board
64 IBM System x3655 Type 7985: Installation Guide
Memory problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The amount of system memory that is displayed is less than the amount of installed physical memory.
1. Make sure that:
v No error LEDs are lit on the operator information panel.
v The memory modules are seated correctly.
v You have installed the correct type of memory (see “Installing a memory
module” on page 14).
v If you changed the memory, you updated the memory configuration in the
Configuration/Setup Utility program.
v All banks of memory are enabled. The server might have automatically
disabled a memory bank when it detected a problem, or a memory bank might have been manually disabled.
Check the POST error log for error message 289:
2.
v If a DIMM was disabled by a system-management interrupt (SMI), replace
the DIMM.
v If a DIMM was disabled by the user or by POST, run the Configuration/Setup
Utility program and enable the DIMM.
Run memory diagnostics (see “Running the diagnostic programs” in the
3. Problem Determination and Service Guide).
4. Make sure that there is no memory mismatch when the server is at the minimum memory configuration (two 512 MB DIMMs).
5. Add one pair of DIMMs at a time, making sure that the DIMMs in each pair are matching.
6. Reseat the following components one at a time, in the order shown, restarting the server each time:
a. DIMMs
b. (Trained service technician only) System board
Replace the components listed in step 7 one at a time, in the order shown,
7. restarting the server each time.
Chapter 5. Solving problems 65
Microprocessor problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The server emits a continuous beep during POST, indicating that the microprocessor is not working correctly.
1. Correct any errors that are indicated by the light path diagnostics LEDs (see “Light path diagnostics” on page 73).
2. Make sure that the server supports all the microprocessors and that the microprocessors match in speed and cache size.
3. (Trained service technician only) Make sure that microprocessor 1 is seated correctly.
4. If there is no indication of which microprocessor has failed, isolate the error by testing with one microprocessor at a time.
5. (Trained service technician only) If there are multiple error codes or light path diagnostics LEDs that indicate a microprocessor error, reverse the locations of two microprocessors to determine whether the error is associated with a microprocessor or with a microprocessor socket.
v If the error is associated with a microprocessor, replace the microprocessor.
v If the error is associated with a microprocessor socket, replace the system
board.
66 IBM System x3655 Type 7985: Installation Guide
Monitor problems
Some IBM monitors have their own self-tests. If you suspect a problem with your monitor, see the documentation that comes with the monitor for instructions for testing and adjusting the monitor.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
Testing the monitor.
The screen is blank.
1. Make sure that the monitor cables are firmly connected.
2. Try using the other video port.
3. Try using a different monitor on the server, or try testing the monitor on a different server.
4. Run the diagnostic programs (see the Problem Determination and Service Guide). If the monitor passes the diagnostic programs, the problem might be a video device driver.
5. Reseat the Remote Supervisor Adapter II SlimLine (if one is present).
6. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Remote Supervisor Adapter II Slimline (if one is present)
b. (Trained service technician only) System board
1. If the server is attached to a KVM switch, bypass the KVM switch to eliminate it as a possible cause of the problem: connect the monitor cable directly to the correct connector on the rear of the server.
2. Make sure that:
v The server is turned on. If there is no power to the server, see “Power
problems” on page 70.
v The monitor cables are connected correctly. v The monitor is turned on and the brightness and contrast controls are
adjusted correctly.
v No beep codes sound when the server is turned on.
Important:
In some memory configurations, the 3-3-3 beep code might sound
during POST, followed by a blank monitor screen. If this occurs and the Boot
Fail Count option in the Start Options of the Configuration/Setup Utility
program is enabled, you must restart the server three times to reset the configuration settings to the default configuration (the memory connector or bank of connectors enabled).
3. Make sure that the correct server is controlling the monitor, if applicable.
4. Make sure that damaged BIOS code is not affecting the video; see the Problem
Determination and Service Guide for information about recovering from a BIOS
failure.
5. See the Problem Determination and Service Guide for information about solving undetermined problems.
Chapter 5. Solving problems 67
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The monitor works when you turn on the server, but the screen goes blank when you start some application programs.
1. Make sure that:
v The application program is not setting a display mode that is higher than the
capability of the monitor.
v You installed the necessary device drivers for the application.
Run video diagnostics (see the Problem Determination and Service Guide for
2. information about running the diagnostic programs).
If the video passes the video diagnostics, the video is good; see the Problem
Determination and Server Guide for information about solving undetermined
problems.
The monitor has screen jitter, or the screen image is wavy, unreadable, rolling, or distorted.
1. If the monitor self-tests show that the monitor is working correctly, consider the location of the monitor. Magnetic fields around other devices (such as transformers, appliances, fluorescent lights, and other monitors) can cause screen jitter or wavy, unreadable, rolling, or distorted screen images. If this happens, turn off the monitor.
Attention: Moving a color monitor while it is turned on might cause screen
discoloration.
Move the device and the monitor at least 305 mm (12 in.) apart, and turn on the monitor.
Notes:
a. To prevent diskette drive read/write errors, make sure that the distance
between the monitor and any external diskette drive is at least 76 mm (3 in.).
b. Non-IBM monitor cables might cause unpredictable problems.
Reseat the following components:
2.
a. Monitor cable
b. Remote Supervisor Adapter II SlimLine (if one is installed)
Replace the following components one at a time, in the order shown, restarting
3. the server each time:
a. Monitor cable
b. Monitor
c. Remote Supervisor Adapter II SlimLine (if one is present)
d. (Trained service technician only) System board
Wrong characters appear on the screen.
1. If the wrong language is displayed, update the BIOS code with the correct language.
2. Reseat the monitor cable.
3. Replace the following components one at a time, in the order shown, restarting the server each time:
a. Monitor
b. (Trained service technician only) System board
68 IBM System x3655 Type 7985: Installation Guide
Optional-device problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
An IBM optional device that was just installed does not work.
An IBM optional device that used to work does not work now.
1. Make sure that:
v The device is designed for the server (see http://www.ibm.com/servers/
eserver/serverproven/compat/us/).
v You followed the installation instructions that came with the device and the
device is installed correctly.
v You have not loosened any other installed devices or cables. v You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or any other device is changed, you must update the configuration.
Reseat the device that you just installed.
2.
3. Replace the device that you just installed.
1. Make sure that all of the hardware and cable connections for the device are secure.
2. If the device comes with test instructions, use those instructions to test the device.
3. Reseat the failing device.
4. Follow the instructions for device maintenance, such as keeping the heads clean, and troubleshooting in the documentation that comes with the device.
5. Replace the failing device.
Chapter 5. Solving problems 69
Power problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The power-control button does not work, and the reset button does not work (the server does not start).
Note: The power-control button
will not function until 20 seconds after the server has been connected to ac power.
The server does not turn off.
1. Make sure that the power-control button is working correctly:
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. (Trained service technician only) Reseat the operator information panel
cables, and then repeat steps 1a and 1b. If the server starts, reseat the operator information panel. If the problem remains, replace the operator information panel.
Make sure that the reset button is working correctly:
2.
a. Disconnect the server power cords.
b. Reconnect the power cords.
c. Reseat the light path diagnostics panel cable, and then repeat steps 1a and
1b.
v If the server starts, replace the light path diagnostics panel.
v If the server does not start, go to step 3.
Make sure that:
3.
v The power cords are correctly connected to the server and to a working
electrical outlet.
v The type of memory that is installed is correct. v The LEDs on the power supply do not indicate a problem. v The microprocessors are installed in the correct sequence.
Reseat the following components:
4.
a. Power switch connector
b. Power backplane
Replace the components listed in step 4 one at a time, in the order shown,
5. restarting the server each time.
6. If you just installed an optional device, remove it, and restart the server. If the server now turns on, you might have installed more devices than the power supply supports.
7. See “Power supply LEDs” in the Problem Determination and Service Guide.
8. See “Solving undetermined problems” in the Problem Determination and Service Guide.
1. Determine whether you are using an Advanced Configuration and Power Interface (ACPI) or non-ACPI operating system. If you are using a non-AC PI operating system complete the following steps:
a. Press Ctrl+Alt+Delete.
b. Turn off the server by pressing the power-control button for 5 seconds.
c. Restart the server.
d. If the server fails POST and the power-control button does not work,
disconnect the ac power cord for 20 seconds; then, reconnect the ac power cord and restart the server.
If the problem remains, or if you are using an ACPI-aware operating system,
2. suspect the system board.
70 IBM System x3655 Type 7985: Installation Guide
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The server unexpectedly shuts down, and the LEDs on the
See “Solving undetermined problems” in the Problem Determination and Service
Guide. operator information panel are not lit.
Serial port problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The number of serial ports that are identified by the operating system is less than the number of installed serial ports.
A serial device does not work.
1. Make sure that:
v Each port is assigned a unique address in the Configuration/Setup Utility
program and none of the serial ports is disabled.
v The serial-port adapter (if one is installed) is seated correctly.
Reseat the serial port adapter.
2.
3. Replace the serial port adapter.
1. Make sure that:
v The device is compatible with the server. v The serial port is enabled and is assigned a unique address. v The device is connected to the correct connector (see “Rear view” on page
35).
Reseat the following components:
2.
a. Failing serial device
b. Serial cable
c. Remote Supervisor Adapter II SlimLine (if one is installed)
Replace the components listed in step 2 one at a time, in the order shown,
3. restarting the server each time.
Chapter 5. Solving problems 71
ServerGuide problems
The following table lists problem symptoms and suggested solutions.
Table 4. ServerGuide Setup and Installation CD
Symptom Suggested action
The ServerGuide Setup and Installation CD will not start.
The ServeRAID program cannot view all installed drives, or the operating system cannot be installed.
The operating-system installation program continuously loops.
The ServerGuide program will not start the operating-system CD.
The operating system cannot be installed; the option is not available.
1. Make sure that the server supports the ServerGuide program and has a startable (bootable) CD (or DVD) drive.
2. If the startup (boot) sequence settings have been altered, make sure that the CD drive is first in the startup sequence.
3. If more than one CD drive is installed, make sure that only one drive is set as the primary drive. Start the CD from the primary drive.
1. Make sure that there are no duplicate IDs or IRQ assignments.
2. Make sure that the hard disk drive is connected correctly.
Make more space available on the hard disk.
Make sure that the operating-system CD is supported by the ServerGuide program. See the ServerGuide Setup and Installation CD label for a list of supported operating-system versions.
Make sure that the operating system is supported on the server. If the operating system is supported, either there is no logical drive defined (SAS RAID systems) or the ServerGuide System Partition is not present. Run the ServerGuide program and make sure that setup is complete.
Software problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
You suspect a software problem.
1. To determine whether the problem is caused by the software, make sure that:
v The server has the minimum memory that is needed to use the software. For
memory requirements, see the information that comes with the software. If you have just installed an adapter or memory, the server might have a memory-address conflict.
v The software is designed to operate on the server. v Other software works on the server. v The software works on another server.
If you receive any error messages while you use the software, see the
2. information that comes with the software for a description of the messages and suggested solutions to the problem.
3. Contact your place of purchase of the software.
72 IBM System x3655 Type 7985: Installation Guide
Universal Serial Bus (USB) port problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A USB device does not work.
1. Run USB diagnostics (see “Running the diagnostic programs” in the Problem Determination and Server Guide.
2. Make sure that:
v The correct USB device driver is installed. v The operating system supports USB devices. v A standard PS/2 keyboard or mouse is not connected to the server. If it is, a
USB keyboard or mouse will not work during POST.
Make sure that the USB configuration options are set correctly in the
3. Configuration/Setup Utility program (see the User’s Guide for more information).
4. If you are using a USB hub, disconnect the USB device from the hub and connect it directly to the server.
Video problems
See “Monitor problems” on page 67.
Light path diagnostics
Use light path diagnostics to diagnose system errors. The light path diagnostics panel is inside the light path diagnostics drawer, on the left front of the server. To access the light path diagnostics panel, slide the latch to the left on the front of the light path diagnostics drawer.
The following illustration shows the controls and LEDs on the light path diagnostics panel.
REMIND
Light Path
Diagnostics
OVER SPEC
CPU
MEM
FAN
PCI
PS1SPPS2
VRM
CNFG
NMI
S ERR
DASD
TEMP
RAID
BRD
To acknowledge a system error but not take immediate action, press the remind button and place light path diagnostics in Remind mode. When the server is in
Chapter 5. Solving problems 73
Remind mode, the system-error LED on the front of the server flashes. If a new failure occurs, the system-error LED is lit again.
Press the reset button to reset the server and run the power-on self-test (POST). You might have to use a pen or the end of a straightened paper clip to press the button.
The server is designed so that LEDs remain lit when the server is connected to an ac power source but is not turned on, provided that the power supply is operating correctly. This feature helps you to isolate the problem when operating system is shut down.
Diagnosing problems using light path diagnostics
LEDs in two locations on the server are available to help you diagnose problems that might occur during installation. Use them in the following order:
1. Light path diagnostics panel - Look at this panel first. If a system error has
occurred, the system-error LED on the front of the light path diagnostics drawer is lit. Slide the latch to the left on the front of the light path diagnostics drawer to access the light path diagnostics panel. Note any LEDs that are lit, and then close the drawer.
Important: If the server has a baseboard management controller, clear the
BMC log and system-event log after you resolve the condition. This will turn off the information LED.
2. LEDs on the system board - To identify the component that is causing the
error, note the lit LED on or beside the component.
Light path diagnostics LEDs
The following table lists the LEDs on the light path diagnostics panel, the problems that they indicate, and actions to solve the problems.
LED Problem Action
None, but the system-error LED is lit.
OVER SPEC There is insufficient power to power
PS 1 The power supply in bay 1 has failed.
An error has occurred and cannot be diagnosed, or the Advanced System Management (ASM) processor on the Remote Supervisor Adapter II SlimLine has failed. The error is not represented by a light path diagnostics LED.
the server.
Check the system error log for information about the error.
1. Add an optional power supply if only one power supply is
2. Use 220 V ac input power.
3. Reseat the following components:
Replace the components listed in step 3 one at a time, in
4.
1. If all 10 fans are installed, make sure power supply 1 and
2. Make sure the power supply is correctly seated and the
3. If the problem remains, replace the power supply.
installed.
a. Power supply
b. Power backplane
the order shown, restarting the server each time.
power supply 2 are installed.
AC power cord is plugged in.
74 IBM System x3655 Type 7985: Installation Guide
LED Problem Action
PS 2 The power supply in bay 2 has failed.
1. If all 10 fans are installed, make sure power supply 1 and power supply 2 are installed.
2. Make sure the power supply is correctly seated and the AC power cord is plugged in.
3. If the problem remains, replace the power supply.
CPU A microprocessor has failed, is
missing, or has been incorrectly installed.
Note: (Trained service technician
only) Make sure that the microprocessors are installed in the correct sequence; see “Installing an additional microprocessor” on page
19).
1. Check the BMC log or the system-error log to determine the reason for the lit LED.
2. Find the failing, missing, or mismatched microprocessor by checking the LEDs.
3. (Trained service technician) Reseat the failing microprocessor.
4. (Trained service technician) Replace the failing microprocessor.
VRM Not Used
CNFG A hardware configuration error has
occurred.
1. When lit in conjunction with the FAN LED, check the fan configuration.
2. When lit in conjunction with the PS1 or PS2 LEDs, check the power supply configuration.
3. When lit in conjunction with the CPU LED, check the microprocessors that were just installed to make sure that they are compatible with each other (see “Installing an additional microprocessor” on page 19 for compatibility requirements).
4. (Trained service technician only) Replace an incompatible microprocessor.
5. Check the system error log for information about the error. Replace any components that are indicated.
MEM A memory error has occurred.
1. Replace the failing DIMM, which is indicated by the lit LED on the system board.
2. If no LEDs on the board are lit, check the memory population sequence (DIMMs not installed in pairs).
NMI A hardware error has been reported to
the operating system.
Note: The PCI or MEM LED might
also be lit.
1. See the BM log and the system-error log (see “Error logs” in the Problem Determination and Service Guide).
2. If the PCI LED is lit, follow the instructions for that LED.
3. If the MEM LED is lit, follow the instructions for that LED.
4. Restart the server.
S ERR A PCI slot error has occurred.
1. See the BMC log or the system-error log.
2. Replace the failing adapter.
3. (Trained service technician only) Replace the system board.
SP There is a fault in the Remote
Supervisor Adapter II SlimLine.
1. Reseat the Remote Supervisor Adapter II SlimLine.
2. Update the firmware for the Remote Supervisor Adapter II SlimLine (see “Updating the firmware” in the Problem Determination and Service Guide).
3. Replace the Remote Supervisor Adapter II SlimLine.
Chapter 5. Solving problems 75
LED Problem Action
DASD A hard disk drive has failed or has
been removed.
Note: The error LED on the failing
hard disk drive is also lit.
1. Reinstall the removed drive.
2. Reseat the following components:
a. Failing hard disk drive
b. Hard disk drive backplane
c. Disk drive cable
d. (Trained service technician only) System board
3.
Replace the components listed in step 2 one at a time, in
the order shown, restarting the server each time.
RAID A RAID adapter has indicated fault.
1. See the BMC log or the system-error log (see “Error logs” in the Problem Diagnostic and Service Guide).
2. Reseat the following components:
a. RAID adapter
b. Hard disk drives
c. (Trained service technician only) System board
Replace the components listed in step 2 one at a time, in
3. the order shown, restarting the server each time.
FAN A fan has failed, is operating too
slowly, or has been removed. The TEMP LED might also be lit.
TEMP A system temperature or component
has exceeded specifications.
Note: A fan LED might also be lit.
1. Reinstall the removed fan.
2. If an individual fan LED is lit, replace the fan.
1. See the BMC log or the system-error log (see “Error logs” in the Problem Determination and Service Guide for the source of the fault).
2. Make sure that the airflow in the server is not blocked.
3. If a fan LED is lit, reseat the fan.
4. Replace the fan for which the LED is lit.
5. Make sure that the room temperature is not too high. See “Features and specifications” on page 4.
6. Call for service.
BRD An error has occurred on the system
board.
1. Check the LEDs on the system board to identify the component that is causing the error.
2. Check the system error log for information about the error.
PCI An error has occurred on a PCI bus or
on the system board. An additional LED will be lit next to a failing PCI slot.
v Check the LEDs on the PCI slots to identify the component
that is causing the error.
v Check the system error log for information about the error. v If you cannot isolate the failing adapter through the LEDs
and the information in the system error log, remove one adapter at a time from the failing PCI bus, and restart the server after each adapter is removed.
v Call for service.
76 IBM System x3655 Type 7985: Installation Guide
Appendix A. Getting help and technical assistance
If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your system or optional device, and whom to call for service, if it is necessary.
Before you call
Before you call, make sure that you have taken these steps to try to solve the problem yourself:
v Check all cables to make sure that they are connected.
v Check the power switches to make sure that the system and any optional
devices are turned on.
v Use the troubleshooting information in your system documentation, and use the
diagnostic tools that come with your system. Information about diagnostic tools is in the Hardware Maintenance Manual and Troubleshooting Guide or Problem
Determination and Service Guide on the IBM Documentation CD that comes with
your system.
Note: For some IntelliStation models, the Hardware Maintenance Manual and Troubleshooting Guide is available only from the IBM support Web site.
v Go to the IBM support Web site at http://www.ibm.com/servers/eservers/support
/xseries/index.html to check for technical information, hints, tips, and new device drivers or to submit a request for information.
can solve many problems without outside assistance by following the
You troubleshooting procedures that IBM provides in the online help or in the documentation that is provided with your IBM product. The documentation that comes with IBM systems also describes the diagnostic tests that you can perform. Most systems, operating systems, and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes. If you suspect a software problem, see the documentation for the operating system or program.
Using the documentation
Information about your IBM system and preinstalled software, if any, or optional device is available in the documentation that comes with the product. That documentation can include printed documents, online documents, readme files, and help files. See the troubleshooting information in your system documentation for instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. To access these pages, go to http://www.ibm.com/servers/eservers/support/xseries/ index.html the IBM Publications Center at http://www.ibm.com/shop/publications/order/.
and follow the instructions. Also, some documents are available through
© Copyright IBM Corp. 2007 77
Getting help and information from the World Wide Web
On the World Wide Web, the IBM Web site has up-to-date information about IBM systems, optional devices, services, and support. The address for IBM System x and xSeries® information is http://www.ibm.com/systems /x/. The address for IBM IntelliStation information is http://www.ibm.com/intellistation/.
You can find service information for IBM systems and optional devices at http://www.ibm.com/servers/eserver/support/xseries/index.html.
Software service and support
Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with System x and xSeries servers, BladeCenter products, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country or region, see http://www.ibm.com/services/sl/products.
For more information about Support Line and other IBM services, see http://www.ibm.com/service/, or see http://www.ibm.com/planetwide/ for support telephone numbers. In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).
Hardware service and support
Important: When you call for service, you will be asked to provide the four-digit
machine type of your system, which is 7985.
You can receive hardware service through IBM Services or through your IBM reseller, if your reseller is authorized by IBM to provide warranty service. See http://www.ibm.com/planetwide/ for support telephone numbers, or in the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).
In the U.S. and Canada, hardware service and support is available 24 hours a day, 7 days a week. In the U.K., these services are available Monday through Friday, from 9 a.m. to 6 p.m.
IBM Taiwan product service
IBM Taiwan product service contact information:
IBM Taiwan Corporation 3F, No 7, Song Ren Rd. Taipei, Taiwan Telephone: 0800-016-888
78 IBM System x3655 Type 7985: Installation Guide
Appendix B. Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. Yo u can send license inquiries, in writing, to:
IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A.
Trademarks
INTERNATIONAL
BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both:
Active Memory IBM TechConnect Active PCI IBM (logo) Tivoli Active PCI-X IntelliStation Tivoli Enterprise AIX NetBAY Update Connector Alert on LAN Netfinity Wake on LAN
© Copyright IBM Corp. 2007 79
BladeCenter Predictive Failure Analysis XA-32 Chipkill ServeRAID XA-64 e-business logo ServerGuide X-Architecture
Eserver ServerProven XpandOnDemand
FlashCopy System x xSeries i5/OS
Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other countries.
Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
Adaptec and HostRAID are trademarks of Adaptec, Inc., in the United States, other countries, or both.
Important notes
Linux is a trademark of Linus Torvalds in the United States, other countries, or both.
Red Hat, the Red Hat “Shadow Man” logo, and all Red Hat-based trademarks and logos are trademarks or registered trademarks of Red Hat, Inc., in the United States and other countries.
Other company, product, or service names may be trademarks or service marks of others.
Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance.
CD drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum possible.
When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately 1000 bytes, MB stands for approximately 1 000 000 bytes, and GB stands for 1 000 000 000 bytes.
When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM.
Maximum memory may require replacement of the standard memory with an optional memory module.
80 IBM System x3655 Type 7985: Installation Guide
IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties.
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM.
Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
Product recycling and disposal
This unit must be recycled or discarded according to applicable local and national regulations. IBM encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. IBM offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products. Information on IBM product recycling offerings can be found on IBM’s Internet site at http://www.ibm.com/ibm/ environment/products/prp.shtml.
Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en la normativa nacional o local aplicable. IBM recomienda a los propietarios de equipos de tecnología de la información (TI) que reciclen responsablemente sus equipos cuando éstos ya no les sean útiles. IBM dispone de una serie de programas y servicios de devolución de productos en varios países, a fin de ayudar a los propietarios de equipos a reciclar sus productos de TI. Se puede encontrar información sobre las ofertas de reciclado de productos de IBM en el sitio web de IBM http://www.ibm.com/ibm/environment/products/prp.shtml.
Notice: This mark applies only to countries within the European Union (EU) and
Norway.
This appliance is labeled in accordance with European Directive 2002/96/EC concerning waste electrical and electronic equipment (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
Appendix B. Notices 81
Remarque: Cette marque s’applique uniquement aux pays de l’Union Européenne
et à la Norvège.
L’etiquette du système respecte la Directive européenne 2002/96/EC en matière de Déchets des Equipements Electriques et Electroniques (DEEE), qui détermine les dispositions de retour et de recyclage applicables aux systèmes utilisés à travers l’Union européenne. Conformément à la directive, ladite étiquette précise que le produit sur lequel elle est apposée ne doit pas être jeté mais être récupéré en fin de vie.
In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, recycling, and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. For proper collection and treatment, contact your local IBM representative.
Battery return program
This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be recycled or disposed of properly. Recycling facilities may not be available in your area. For information on disposal of batteries outside the United States, go to http://www.ibm.com/ibm/environment/ products/batteryrecycle.shtml or contact your local waste disposal facility.
In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333. Have the IBM part number listed on the battery available prior to your call.
For Taiwan: Please recycle batteries.
For the European Union:
82 IBM System x3655 Type 7985: Installation Guide
For California: Perchlorate material special handling may apply. See
http://www.dtsc.ca.gov/hazardouswaste/perchlorate/.
The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchlorate Materials. This product/part may include a lithium manganese dioxide battery which contains a perchlorate substance.
Electronic emission notices
Federal Communications Commission (FCC) statement
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d’Industrie Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Australia and New Zealand Class A statement
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
United Kingdom telecommunications safety requirement
Notice to Customers
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect connection to public telecommunication systems in the United Kingdom.
Appendix B. Notices 83
European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards.
This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN
55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
Taiwanese Class A warning statement
Chinese Class A warning statement
Japanese Voluntary Control Council for Interference (VCCI) statement
84 IBM System x3655 Type 7985: Installation Guide
Index
A
ac power LED 35 acoustical noise emissions 5 adapter
installing
26
Remote Supervisor Adapter II SlimLine 28 slot locations 27
system requirements 27 ASM processor 74 attention notices 3
B
baseboard management controller utility programs 54 battery
return
program 82
beep codes 57
C
caution statements 3 CD/DVD drive
activity
LED 35
problems 61 CD/DVD-eject button 34 Class A electronic emission notice 83 command-line interface
commands
identify
55
power 55 sel 55 sysinfo 55
for remote management 54 Configuration/Setup Utility program 39 configuring hardware 39 connectors
front
30
rear 30 cooling 5 cover
installing
30
removing 11
D
danger statements 3 device scan sequence 27 DIMMs
connector
order of installation 15 display problems 67 documentation CD 2 drive, hot-swap, installing 17, 19
locations 16
E
electrical input 5 electronic emission Class A notice 83 environment 5 error messages, POST 58 error symptoms
CD
or DVD drive 61
general 62 hard disk drive 62 intermittent 63 keyboard, USB 63 memory 65 microprocessor 66 monitor 67 mouse, USB 63 optional devices 69 pointing device, USB 63 power 70 serial port 71 software 72 USB port 73
Ethernet
activity
LED 35
connector 36 link status LED 35 system-management connector 35
F
FCC Class A notice 83 features 4 filler panel 10, 19, 29 firmware code, updating 54 firmware updates 1
H
hard disk drive
installing
17
problems 62 hard drive activity LED 34 heat output 5 hot-swap drive, installing 17 humidity 5
I
important notices 3 information LED 34 installing
adapters
cover 30
DIMMs 14
hard disk drives 17
hot-swap drive 17, 19
microprocessor 19
Remote Supervisor Adapter II SlimLine 28
26
© Copyright IBM Corp. 2007 85
intermittent problems 63
L
LEDs
Ethernet
activity 35
Ethernet-link status 35 front 33 rear 35
light path diagnostics
LEDs
74
panel 73
locator LED 34, 36
M
major components 6 memory
installing problems 65
memory module
specifications
microprocessor
heat installing 19 problems 66
specifications 5 monitor problems 67 mouse problems 64
14
5
sink 22
power-on LED
front
36
rear 34
problems
CD/DVD
drive 61
hard disk drive 62 intermittent 63 keyboard 63 memory 65 microprocessor 66 monitor 67 optional devices 69 power 70 serial port 71 software 72 solving 57 USB port 73 video 73
product recycling 81
R
recycling, product 81 Remote Supervisor Adapter II SlimLine, installing 28 riser-card assembly
installing removing 24 replacing 23
24
N
notes 3 notes, important 80 notices
electronic
emission 83
FCC, Class A 83 notices and statements 3
O
online documentation 1 operator information panel 33 optional device problems 69 OSA SMBridge management utility program
enabling
and configuring 43
installing 52
P
PCI
expansion pointing device problems 64 POST error messages 58 power
problems power supply
specifications power-cord connector 35
slots 5
70
5
S
SAS
hard
disk drive, installing 17
integrated controller 27 SAS connector 35 scan sequence, default 27 SCSI
See
SAS
serial connector 36 serial over LAN
commands
connect identify 55 power 55 reboot 55 sel get 55 sol 55
sysinfo 55 serial port problems 71 ServerGuide
error
using 39 service processor, defined 36 size 5 software problems 72 solving problems 57 specifications 4 statements and notices 3 status LEDs 35 system-error LED
front
55
symptoms 72
36
86 IBM System x3655 Type 7985: Installation Guide
Loading...