Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 163,
the IBM Safety Information and IBM Environmental Notices and User's Guide on the IBM System x Documentation CD, and the
IBM Warranty Information document that comes with your server.
Each caution and danger statement in this document is labeled with a number. This
number is used to cross reference an English-language caution or danger
statement with translated versions of the caution or danger statement in the SafetyInformation document.
For example, if a caution statement is labeled “Statement 1,” translations for that
caution statement are in the Safety Information document under “Statement 1.”
Be sure to read all caution and danger statements in this document before you
perform the procedures. Read any additional safety information that comes with the
server or optional device before you install the device.
Attention:Use No. 26 AWG or larger UL-listed or CSA certified
telecommunication line cord.
viiiSystem x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Statement 1:
DANGER
Electrical current from power, telephone, and communication cables is
hazardous.
To avoid a shock hazard:
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
v Connect all power cords to a properly wired and grounded electrical
outlet.
v Connect to properly wired outlets any equipment that will be attached to
this product.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached
devices.
To Connect:To Disconnect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
5. Turn device ON.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
Safetyix
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
xSystem x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly
with optical instruments, and avoid direct exposure to the beam.
Class 1 Laser Product
Laser Klasse 1
Laser Klass 1
Luokan 1 Laserlaite
Appareil A Laser de Classe 1
`
Safetyxi
Statement 4:
≥ 18 kg (39.7 lb)≥ 32 kg (70.5 lb)≥ 55 kg (121.2 lb)
CAUTION:
Use safe practices when lifting.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
xiiSystem x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
Statement 12:
CAUTION:
The following label indicates a hot surface nearby.
Statement 26:
CAUTION:
Do not place any object on top of rack-mounted devices.
This server is suitable for use on an IT power-distribution system whose maximum
phase-to-phase voltage is 240 V under any distribution fault condition.
Important: This product is not suitable for use with visual display workplace
devices according to Clause 2 of the German Ordinance for Work with Visual
Display Units.
Safetyxiii
xivSystem x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Chapter 1. The System x3650 M3 server
This Installation and User's Guide contains instructions for setting up your IBM
®
System x3650 M3 Types 4255, 7945, or 7949 server, instructions for installing
optional devices, and instructions for starting and configuring the server. For
diagnostic and troubleshooting information, see the Problem Determination andService Guide that is on the IBM Documentation CD.
1
The IBM System x3650 M3 Types 4255, 7945, or 7949 server is a 2-U
-high server
that is ideally suited for networking environments that require superior
microprocessor performance, efficient memory management, and flexibility.
Performance, ease of use, reliability, and expansion capabilities were key
considerations in the design of the server. These design features make it possible
for you to customize the system hardware to meet your needs today and provide
flexible expansion capabilities for the future.
The server comes with a limited warranty. For information about the terms of the
warranty and getting service and assistance, see the Warranty Information
document on the IBM Documentation CD.
®
The server contains IBM Enterprise X-Architecture
technologies, which help
increase performance and reliability. For more information, see “What your server
offers” on page 8 and “Reliability, availability, and serviceability features” on page
11.
You can obtain up-to-date information about the server and other IBM server
products at http://www.ibm.com/systems/x/. At http://www.ibm.com/support/
mysupport/, you can create a personalized support page by identifying IBM
products that are of interest to you. From this personalized page, you can subscribe
to weekly e-mail notifications about new technical documents, search for information
and downloads, and access various administrative services.
If you participate in the IBM client reference program, you can share information
about your use of technology, best practices, and innovative solutions; build a
professional network; and gain visibility for your business. For more information
about the IBM client reference program, see http://www.ibm.com/ibm/
clientreference/.
The server comes with eight 2.5-inch SAS hot-swap hard disk drive bays. Most
models contain a ServeRAID SAS controller and are capable of expansion to
sixteen 2.5-inch SAS hot-swap hard disk drive bays.
1. Racks are measured in vertical increments of 1.75 inches each. Each increment is called a “U”. A 1-U-high device is 1.75 inches
tall.
The following illustration shows a server with eight SAS hard disk drive bays.
You can purchase an optional kit to install the tape drive.
SAS hard disk
drive bays
01234567
You can purchase an optional kit to install the eight additional SAS hard disk drive
bays.
SAS hard disk
drive bays
01234567
8 9 10 1112 131415
The SAS ID for each bay is printed on the server front, above each bay.
If firmware and documentation updates are available, you can download them from
the IBM Web site. The server might have features that are not described in the
documentation that comes with the server, and the documentation might be updated
occasionally to include information about those features, or technical updates might
be available to provide additional information that is not included in the server
documentation. To check for updates, complete the following steps.
Note: Changes are made periodically to the IBM Web site. Procedures for locating
firmware and documentation might vary slightly from what is described in this
document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers for firmware updates,
or click Publications lookup for documentation updates.
Record information about the server in the following table.
Product nameIBM System x3650 M3 server
Machine type4255, 7945, or 7949
Model number_____________________________________________
Serial number_____________________________________________
2System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
The model number and serial number are on the ID label on the bezel, as shown in
the following illustration.
Note: The illustrations in this document might differ slightly from your hardware.
ID label
You can download an IBM ServerGuide Setup and Installation CD to help you
configure the hardware, install device drivers, and install the operating system. For
more information, see “Using the ServerGuide Setup and Installation CD” on page
150.
For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
See the Rack Installation Instructions document on the IBM Documentation CD for
complete rack installation and removal instructions.
The IBM Documentation CD
The IBM Documentation CD contains documentation for your server in Portable
Document Format (PDF) and includes the IBM Documentation Browser to help you
find information quickly.
Hardware and software requirements
The IBM Documentation CD requires the following minimum hardware and
software:
v Microsoft Windows XP, Windows 2000, or Red Hat Linux
v 100 MHz microprocessor
v 32 MB of RAM
v Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
systems
Using the Documentation Browser
Use the Documentation Browser to browse the contents of the CD, read brief
descriptions of the documents, and view documents, using Adobe Acrobat Reader
or xpdf. The Documentation Browser automatically detects the regional settings in
use in your server and displays the documents in the language for that region (if
available). If a document is not available in the language for that region, the
English-language version is displayed.
Use one of the following procedures to start the Documentation Browser:
v If Autostart is enabled, insert the CD into the CD or DVD drive. The
Documentation Browser starts automatically.
Chapter 1. The System x3650 M3 server3
v If Autostart is disabled or is not enabled for all users, use one of the following
procedures:
– If you are using a Windows operating system, insert the CD into the CD or
DVD drive and click Start --> Run.IntheOpen field, type
e:\win32.bat
where e is the drive letter of the CD or DVD drive, and click OK.
– If you are using Red Hat Linux, insert the CD into the CD or DVD drive; then,
run the following command from the /mnt/cdrom directory:
sh runlinux.sh
Select your server from the Product menu. The Available Topics list displays all
the documents for your server. Some documents might be in folders. A plus sign (+)
indicates each folder or document that has additional documents under it. Click the
plus sign to display the additional documents.
When you select a document, a description of the document appears under TopicDescription. To select more than one document, press and hold the Ctrl key while
you select the documents. Click View Book to view the selected document or
documents in Acrobat Reader or xpdf. If you selected more than one document, all
the selected documents are opened in Acrobat Reader or xpdf.
To search all the documents, type a word or word string in the Search field and
click Search. The documents in which the word or word string appears are listed in
order of the most occurrences. Click a document to view it, and press Crtl+F to use
the Acrobat search function, or press Alt+F to use the xpdf search function within
the document.
Click Help for detailed information about using the Documentation Browser.
Related documentation
This Installation and User’s Guide contains general information about the server,
including how to set up the server, how to install supported optional devices, and
how to configure the server. The following documentation also comes with the
server:
v Warranty Information
This printed document contains information about the terms of the warranty.
v Safety Information
This document is in PDF on the IBM Documentation CD. It contains translated
caution and danger statements. Each caution and danger statement that appears
in the documentation has a number that you can use to locate the corresponding
statement in your language in the Safety Information document.
v Rack Installation Instructions
This printed document contains instructions for installing the server in a rack.
v Problem Determination and Service Guide
This document is in PDF on the IBM Documentation CD. It contains information
to help you solve problems yourself, and it contains information for service
technicians.
4System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
v Environmental Notices and User Guide
This document is in PDF on the IBM Documentation CD. It contains translated
environmental notices.
v IBM License Agreement for Machine Code
This document is in PDF on the IBM Documentation CD. It provides translated
versions of the IBM License Agreement for Machine Code for your product.
v IBM MCP Linux License Information and Attributions
This document is in PDF on the IBM Documentation CD. It provides information
about the open-source notices.
Depending on the server model, additional documentation might be included on the
IBM Documentation CD.
®
The System x
and xSeries®Tools Center is an online information center that
contains information about tools for updating, managing, and deploying firmware,
device drivers, and operating systems. The System x and xSeries Tools Center is at
http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
The server might have features that are not described in the documentation that
comes with the server. The documentation might be updated occasionally to include
information about those features, or technical updates might be available to provide
additional information that is not included in the server documentation. These
updates are available from the IBM Web site. To check for updated documentation
and technical updates, complete the following steps.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Publications lookup.
4. From the Product family menu, select System x3650 M3 and click Continue.
Chapter 1. The System x3650 M3 server5
Notices and statements in this document
The caution and danger statements in this document are also in the multilingual
Safety Information document, which is on the Documentation CD. Each statement is
numbered for reference to the corresponding statement in your language in the
Safety Information document.
The following notices and statements are used in this document:
v Note: These notices provide important tips, guidance, or advice.
v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage might occur.
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
Features and specifications
The following information is a summary of the features and specifications of the
server. Depending on the model, some features might not be available, or some
specifications might not apply.
Racks are marked in vertical increments of 4.45 cm (1.75 inches). Each increment
is referred to as a unit, or “U.” A 1-U-high device is 1.75 inches tall.
Notes:
1. Power consumption and heat output vary depending on the number and type of
optional features that are installed and the power-management optional features
that are in use.
2. The sound levels were measured in controlled acoustical environments
according to the procedures specified by the American National Standards
Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO
9296. Actual sound-pressure levels in a given location might exceed the
average values stated because of room reflections and other nearby noise
sources. The declared sound-power levels indicate an upper limit, below which
a large number of computers will operate.
6System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Table 1. Features and specifications
Microprocessor:
v Supports up to two Intel Xeon
multi-core microprocessors (one
installed)
v Level-3 cache
v QuickPath Interconnect (QPI) links
speed up to 6.4 GT per second
Note:
v Do not install an Intel Xeon
series microprocessor and an Xeon
5600 series microprocessor in the same
server.
v Use the Setup utility to determine the
type and speed of the microprocessors.
v For a list of supported microprocessors,
see http://www.ibm.com/servers/eserver/
serverproven/compat/us/.
Memory:
v Minimum: 2 GB
v Maximum: 192 GB
– 48 GB using unbuffered DIMMs
(UDIMMs)
– 192 GB using registered DIMMs
(RDIMMs)
v Type: PC3-10600R-999, 800, 1067, and
1333 MHz, ECC, DDR3 registered or
unbuffered SDRAM DIMMs
v Slots: 18 dual inline
v Supports (depending on the model):
– 2 GB and 4 GB unbuffered DIMMs
– 2 GB, 4 GB, 8 GB, and 16 GB
registered DIMMs
SATA optical drives (optional):
v DVD-ROM
v Multi-burner
Hard disk drive expansion bays
(depending on the model):
v Eight 2.5-inch SAS hot-swap bays for
hard disk drive bays with option to add
eight more 2.5-inch SAS hot-swap hard
disk drive bays
v Four 2.5-inch simple-swap, solid state
SATA hard disk drive bays
PCI expansion slots:
v Two PCI Express riser cards with two
PCI Express x8 slots (x8 lanes) each,
standard
v Support for the following optional riser
cards:
– Two 133 MHz/64-bit PCI-X 1.0a slots
– One PCI Express x16 slot (x16
lanes)
™
™
5500
™
Size (2U):
v Height: 85.2 mm (3.346 in.)
v Depth: EIA flange to rear - 698 mm
(27.480 in.), Overall - 729 mm (28.701
in.)
v Width: With top cover - 443.6 mm
(17.465 in.), With front bezel - 482.0
mm (18.976 in.)
v Weight: approximately 21.09 kg (46.5
lb) to 25 kg (55 lb) depending upon
configuration
Integrated functions:
v Integrated management module (IMM),
which provides service processor
control and monitoring functions, video
controller, and (when the optional
virtual media key is installed) remote
keyboard, video, mouse, and remote
hard disk drive capabilities
v Dedicated or shared management
network connections
v Serial over LAN (SOL) and serial
redirection over Telnet or Secure Shell
(SSH)
v One systems-management RJ-45 for
connection to a dedicated
systems-management network
v Support for remote management
presence through an optional virtual
media key
v Broadcom BCM5709 Gb Ethernet
controller with TCP/IP Offload Engine
(TOE) and Wake on LAN support
v Four Ethernet ports (two on system
board and two additional ports when
the optional IBM Dual-Port 1 Gb
Ethernet Daughter Card is installed)
v One serial port, shared with the
integrated management module (IMM)
v Four Universal Serial Bus (USB) ports
(two on front, two on rear of server),
v2.0 supporting v1.1, plus one or more
dedicated internal USB ports on the
SAS riser-card
v Two video ports (one on front and one
on rear of server)
v One SATA tape connector, one USB
tape connector, and one tape power
connector on SAS riser-card (some
models)
v Support for hypervisor function through
an optional USB flash device on the
SAS riser-card (not available on
simple-swap models)
Note: In messages and documentation,
the term service processor refers to the
integrated management module (IMM).
Video controller (integrated into IMM):
v Matrox G200eV (two analog ports - one
front and one rear that can be connected
at the same time)
Note: The maximum video resolution is
1600 x 1200 at 75 Hz.
– SVGA compatible video controller
– DDR2 250 MHz SDRAM video
memory controller
– Avocent Digital Video Compression
– 16 MB of video memory (not
expandable)
ServeRAID controller (depending on the
model):
v A ServeRAID-BR10il v2 SAS/SATA
adapter that provides RAID levels 0, 1,
and 1E (comes standard on some
hot-swap models).
v An optional ServeRAID-BR10il SAS/SATA
adapter that provides RAID levels 0, 1,
and 1E can be ordered.
v An optional ServeRAID-MR10i SAS/SATA
adapter that provides RAID levels 0, 1, 5,
6, 10, 50, and 60 can be ordered.
v An optional ServeRAID-M1015 SAS/SATA
adapter that provides RAID levels 0, 1,
and 10 with optional RAID 5/50 and SED
(Self Encrypting Drive) upgrade.
v An optional ServeRAID-M5014 SAS/SATA
adapter that provides RAID levels 0, 1, 5,
10 and 50 with optional battery and RAID
6/60 and SED upgrade.
v An optional ServeRAID-M5015 SAS/SATA
adapter with battery that provides RAID
levels 0, 1, 5, 10, and 50 with optional
RAID 6/60 and SED upgrade
Notes:
1. RAID is supported in hot-swap models
only.
2. The ServeRAID controllers are installed
in a PCI Express x8 mechanical slot (x4
electrical); however, the controllers run
at x4 bandwidth.
Chapter 1. The System x3650 M3 server
7
Table 1. Features and specifications (continued)
Electrical input with hot-swap ac power
supplies:
v Sine-wave input (47 - 63 Hz) required
v Input voltage range automatically
selected
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA)
approximately:
– Minimum: 0.090 kVA
– Maximum: 0.700 kVA
Environment:
v Air temperature:
– Server on: 10°C to 35°C (50.0°F to
95.0°F); altitude: 0 to 914.4 m (3000
ft). Decrease system temperature
by 1°C for every 1000-foot increase
in altitude.
– Server off: 5°C to 45°C (41.0°F to
113.0°F); maximum altitude: 3048 m
(10000 ft)
– Shipment: -40°C to +60°C (-40°F to
140°F); maximum altitude: 3048 m
(10000 ft)
v Humidity:
– Server on: 20% to 80%; maximum
dew point: 21°C; maximum rate of
change 5°C per hour.
– Server off: 8% to 80%; maximum
dew point: 27°C
– Shipment: 5% to 100%
v Particulate contamination:
Attention: Airborne particulates and
reactive gases acting alone or in
combination with other environmental
factors such as humidity or
temperature might pose a risk to the
server. For information about the limits
for particulates and gases, see
“Particulate contamination” on page
165.
Hot-swap fans:
Three - provide redundant cooling.
Power supply:
v Up to two hot-swap power supplies for
redundancy support
– 460-watt ac
– 675-watt ac
– 675-watt high-efficiency ac
– 675-watt dc
Note: You cannot mix 460-watt and
675-watt power supplies, or high-efficiency
and non-high-efficiency power supplies, or
ac and dc power supplies in the server.
Acoustical noise emissions:
v Declared sound power, idle: 6.3 bel
v Declared sound power, operating: 6.5 bel
Heat output:
Approximate heat output:
v Minimum configuration: 662 Btu per hour
(194 watts)
v Maximum configuration: 2302 Btu per
hour (675 watts)
What your server offers
The server uses the following features and technologies:
v UEFI-compliant server firmware
IBM System x Server Firmware offers several features, including Unified
Extensible Firmware Interface (UEFI) 2.1 compliance, Active Energy Manager
technology, enhanced RAS capabilities, and BIOS compatibility support. UEFI
replaces the basic input/output system (BIOS) and defines a standard interface
between the operating system, platform firmware, and external devices.
UEFI-compliant System x servers are capable of booting UEFI-compliant
operating systems, BIOS-based operating systems, and BIOS-based adapters as
well as UEFI-compliant adapters.
Note: The server does not support DOS.
v Integrated management module
The integrated management module (IMM) combines service processor
functions, video controller, and (when an optional virtual media key is installed)
remote presence function in a single chip. The IMM provides advanced
service-processor control, monitoring, and alerting function. If an environmental
condition exceeds a threshold or if a system component fails, the IMM lights
LEDs to help you diagnose the problem, records the error in the event log, and
alerts you to the problem. Optionally, the IMM also provides a virtual presence
capability for remote server management capabilities. The IMM provides remote
server management through industry-standard interfaces:
– Intelligent Platform Management Interface (IPMI) version 2.0
8System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
– Simple Network Management Protocol (SNMP) version 3
– Common Information Model (CIM)
– Web browser
v Remote presence capability and blue-screen capture
The optional virtual media key is required to enable the remote presence and
blue-screen capture features. The remote presence feature provides the following
functions:
– Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz,
regardless of the system state
– Remotely accessing the server, using the keyboard and mouse from a remote
client
– Mapping the CD or DVD drive, diskette drive, and USB flash drive on a
remote client, and mapping ISO and diskette image files as virtual drives that
are available for use by the server
– Uploading a diskette image to the IMM memory and mapping it to the server
as a virtual drive
The blue-screen capture feature captures the video display contents before the
IMM restarts the server when the IMM detects an operating-system hang
condition. A system administrator can use the blue-screen capture to assist in
determining the cause of the hang condition.
v IBM Dynamic System Analysis Preboot diagnostics programs
The Dynamic System Analysis (DSA) Preboot diagnostics programs are stored
on the integrated USB memory. It collects and analyzes system information to aid
in diagnosing server problems. The diagnostic programs collect the following
information about the server:
– System configuration
– Network interfaces and settings
– Installed hardware
– Light path diagnostics status
– Service processor status and configuration
– Vital product data, firmware, and UEFI (formerly BIOS) configuration
– Hard disk drive health
– RAID controller configuration
– Event logs for ServeRAID controllers and service processors
The diagnostic programs create a merged log that includes events from all
collected logs. The information is collected into a file that you can send to IBM
service and support. Additionally, you can view the information locally through a
generated text report file. You can also copy the log to a removable media and
view the log from a Web browser.
For additional information about DSA Preboot diagnostics, see the ProblemDetermination and Service Guide on the IBM Documentation CD
v IBM Systems Director
IBM Systems Director is a workgroup-hardware-management tool that you can
use to centrally manage System x and xSeries servers. For more information,
see the IBM Systems Director documentation on the IBM Systems Director CD.
v Active Energy Manager
The Active Energy Manager solution is an IBM Systems Director extension that
measures and reports server power consumption as it occurs. This enables you
to monitor power consumption in correlation to specific software application
Chapter 1. The System x3650 M3 server9
programs and hardware configurations. You can obtain the measurement values
through the systems-management interface and view them, using IBM Systems
Director. For more information, see the IBM Director documentation on the IBMSystems Director CD, or see http://www.ibm.com/systems/management/director/
extensions/actengmrg.html.
v IBM X-Architecture technology
IBM X-Architecture technology combines proven, innovative IBM designs to make
your Intel-processor-based server powerful, scalable, and reliable. For more
information, see http://www.ibm.com/servers/eserver/xseries/xarchitecture/
enterprise/index.html.
™
– Active
Memory
The Active Memory™feature improves the reliability of memory through
memory mirroring. Memory mirroring stores data in two pairs of DIMMs
simultaneously.
– Large system-memory capacity
The memory bus supports up to 192 GB of system memory when registered
DIMMs are installed. The server supports up to 48 GB if unbuffered DIMMs
are installed. The memory controller supports error correcting code (ECC) for
up to 18 industry-standard PC3-10600R-999, 800, 1067, and 1333 MHz,
DDR3 (third-generation double-data-rate), synchronous dynamic random
access memory (SDRAM) dual inline memory modules (DIMMs).
v IBM ServerGuide Setup and Installation CD
The ServerGuide Setup and Installation CD, which you can download from the
Web, provides programs to help you set up the server and install a Windows
operating system. The ServerGuide program detects installed optional hardware
devices and provides the correct configuration programs and device drivers. For
more information about the ServerGuide Setup and Installation CD, see “Using
the ServerGuide Setup and Installation CD” on page 150.
v Integrated network support
The server comes with two integrated Broadcom Gigabit Ethernet controllers,
which support connection to a 10 Mbps, 100 Mbps, or 1000 Mbps network. For
more information, see “Configuring the Gigabit Ethernet controller” on page 156.
v Large data-storage and hot-swap capability
The server supports up to eight or sixteen 2.5-inch hot-swap hard disk drives in
the hot-swap bays (depending on the model and optional devices installed). With
the hot-swap feature, you can add, remove, or replace hard disk drives without
turning off the server.
v Light path diagnostics
Light path diagnostics provides LEDs to help you diagnose problems. For more
information, see the section about light path diagnostics in the ProblemDetermination and Service Guide.
v PCI adapter capabilities
The server supports up to four PCI interface slots. For more information, see
“Installing a PCI adapter” on page 52.
v Memory mirroring
Memory mirroring improves the availability of memory by writing information to
the main memory and redundant locations in a mirrored pair of DIMMs.
v Redundant connection
The addition of the optional Ethernet daughter card provides failover capability to
a redundant Ethernet connection with the applicable application installed. If a
problem occurs with the primary Ethernet connection and the optional Ethernet
10System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
daughter card is installed on the server, all Ethernet traffic that is associated with
the primary connection is automatically switched to the optional redundant
Ethernet daughter card connection. If the applicable device drivers are installed,
this switching occurs without data loss and without user intervention.
v Redundant cooling and optional power capabilities
The server supports three hot-swap fans, which provide redundant cooling.
Redundant cooling enables continued operation if one of the fans fails. The
server supports a maximum of two 675-watt or 460-watt hot-swap power
supplies, which provide redundancy and hot-swap capability for a typical
configuration. The server comes with one 675-watt or 460-watt hot-swap power
supply. You can order the second optional power supply for power redundancy. If
the maximum load on the server is less than 675-watts (or 460-watt, depending
on what kind of power supply you use) and a problem occurs with one of the
power supplies, the other power supply can meet the power requirements.
Note: If the maximum load on the server is greater than 675-watts (or 460-watt,
depending on what kind of power supply you use) and a problem occurs with one
of the power supplies, Active Energy Manager can act to minimize the load
somewhat so that the server can function with the remaining power supply.
v ServeRAID support
The server supports an internal ServeRAID SAS controller, which is required for
you to use the hot-swap hard disk drives and to create redundant array of
independent disks (RAID) configurations.
v Systems-management capabilities
The server contains an integrated management module (IMM) which enables you
to manage the functions of the server locally and remotely. The addition of the
optional IBM Virtual Media Key provides remote presence and blue-screen
capture capability. The IMM also provides system monitoring, event recording,
and dial-out alert capability.
v TCP/IP offload engine (TOE) support
The Ethernet controllers in the server support TOE, which is a technology that
offloads the TCP/IP flow from the microprocessors and I/O subsystem to increase
the speed of the TCP/IP flow. When an operating system that supports TOE is
running on the server and TOE is enabled, the server supports TOE operation.
See the operating-system documentation for information about enabling TOE.
Note: As of the date of this document, the Linux operating system does not
support TOE.
Reliability, availability, and serviceability features
Three important computer design features are reliability, availability, and
serviceability (RAS). The RAS features help to ensure the integrity of the data that
is stored in the server, the availability of the server when you need it, and the ease
with which you can diagnose and repair problems.
The server has the following RAS features:
v 3-year parts and 3-year labor limited warranty for machine types 7945 and 7949
and 4-year parts and 4-year labor limited warranty for machine type 4255
v Automatic error retry and recovery
v Automatic restart after a power failure
v Built-in monitoring for fan, power, temperature, voltage, and power-supply
redundancy
v Cable-presence detection on most connectors
Chapter 1. The System x3650 M3 server11
v Chipkill memory protection
v Dual redundant UEFI server firmware images
v Error codes and messages
v Error correcting code (ECC) L2 cache and system memory
v Hot-swap cooling fans with speed-sensing capability
v Hot-swap hard disk drives
v Information and light path diagnostics LED panels
v Integrated management module (service processor)
v Memory mirroring
v Menu-driven setup, system configuration, and redundant array of independent
disks (RAID) configuration programs
v Parity checking or CRC checking on the serially-attached SCSI (SAS) bus and
PCI buses
v Power management: compliance with Advanced Configuration and Power
Interface (ACPI)
v Power-on self-test (POST)
v Predictive Failure Analysis (PFA) alerts on memory, SAS/SATA hard disk drives,
fans, and power supplies
v Redundant Ethernet capabilities with failover support
v Redundant hot-swap power supplies
v Remind button to temporarily turn off the system-error LED
v Remote system problem-determination support
v Standby voltage for systems-management features and monitoring
v Startup (boot) from LAN through Preboot Execution Environment (PXE) boot
agent utility or Dynamic Host Configuration Protocol/Boot Protocol
(DHCP/BOOTP)
v System auto-configuring from the configuration menu
v System error logging (POST and service processor)
v Systems-management monitoring through the Inter-Integrated Circuit (I
2
C) bus
v Upgradeable POST, UEFI, diagnostics, service processor microcode, and
read-only memory (ROM) resident code, locally or over the LAN
v Vital product data (VPD) on microprocessors, system board, power supplies, and
SAS (hot-swap-drive) backplane
v Wake on LAN capability
IBM Systems Director
IBM Systems Director is a platform-management foundation that streamlines the
way you manage physical and virtual systems in a heterogeneous environment. By
using industry standards, IBM Systems Director supports multiple operating systems
and virtualization technologies in IBM and non-IBM x86 platforms.
Through a single user interface, IBM Systems Director provides consistent views for
viewing managed systems, determining how these systems relate to one another,
and identifying their statuses, helping to correlate technical resources with business
needs. A set of common tasks that are included with IBM Systems Director provides
many of the core capabilities that are required for basic management, which means
instant out-of-the-box business value. These common tasks include discovery,
inventory, configuration, system health, monitoring, updates, event notification, and
automation for managed systems.
The IBM Systems Director Web and command-line interfaces provide a consistent
interface that is focused on driving these common tasks and capabilities:
v Discovering, navigating, and visualizing systems on the network with the detailed
inventory and relationships to the other network resources
12System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
v Notifying users of problems that occur on systems and the ability to isolate the
sources of the problems
v Notifying users when systems need updates and distributing and installing
updates on a schedule
v Analyzing real-time data for systems and setting critical thresholds that notify the
administrator of emerging problems
v Configuring settings of a single system and creating a configuration plan that can
apply those setting to multiple systems
v Updating installed plug-ins to add new features and functions to the base
capabilities
v Managing the life cycles of virtual resources
For more information about IBM Systems Director, see the documentation on the
IBM Systems Director DVD that comes with the server and the IBM xSeries
Systems Management Web page at http://www.ibm.com/systems/management/,
which presents an overview of IBM Systems Management and IBM Systems
Director.
The UpdateXpress System Pack Installer
The UpdateXpress System Pack Installer detects supported and installed device
drivers and firmware in the server and installs available updates. For additional
information and to download the UpdateXpress System Pack Installer, go to the
System x and BladeCenter Tools Center at http://publib.boulder.ibm.com/infocenter/
toolsctr/v1r0/index.jsp and click UpdateXpress System Pack Installer.
Server controls, LEDs, and power
This section describes the controls and light-emitting diodes (LEDs) and how to turn
the server on and off.
Chapter 1. The System x3650 M3 server13
Front view
The following illustration shows the controls, connectors, and hard disk drive bays
on the front of the server.
Hard disk drive
activity LED (green)
Hard disk drive
status LED (amber)
Video
connector
USB 1
connector
USB 2
connector
Operator
information panel
Rack
release
latch
Hard disk
drive bays
Bay 15Bay 0
CD/DVD drive
activity LED
CD/DVD
eject button
Rack
release
latch
CD/DVD drive
(optical drive)
Hard disk drive activity LED: Each hard disk drive has an activity LED. When this
LED is flashing, it indicates that the drive is in use.
Hard disk drive status LED: Each hard disk drive has a status LED. When this
LED is lit, it indicates that the drive has failed. When this LED is flashing slowly
(one flash per second), it indicates that the drive is being rebuilt as part of a RAID
configuration. When the LED is flashing rapidly (three flashes per second), it
indicates that the controller is identifying the drive.
Video connector: Connect a monitor to this connector. The video connectors on
the front and rear of the server can be used simultaneously.
USB connectors: Connect a USB device, such as USB mouse, keyboard, or other
USB device, to either of these connectors.
Operator information panel: This panel contains controls, light-emitting diodes
(LEDs), and connectors. For information about the controls and LEDs on the
operator information panel, see “Operator information panel” on page 15.
Rack release latches: Press these latches to release the server from the rack.
Optional CD/DVD-eject button: Press this button to release a CD or DVD from the
CD-RW/DVD drive.
Optional CD/DVD drive activity LED: When this LED is lit, it indicates that the
CD-RW/DVD drive is in use.
14System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Operator information panel
The following illustration shows the controls and LEDs on the operator information
panel.
The following controls and LEDs are on the operator information panel:
v Power-control button and power-on LED: Press this button to turn the server
on and off manually or to wake the server from a reduced-power state. The
states of the power-on LED are as follows:
Off: AC power is not present, or the power supply or the LED itself has failed.
Flashing rapidly (4 times per second): The server is turned off and is not
ready to be turned on. The power-control button is disabled. This will last
approximately 20 to 40 seconds.
Note: Approximately 40 seconds after the server is connected to ac power,
the power-control button becomes active.
Flashing slowly (once per second): The server is turned off and is ready to
be turned on. You can press the power-control button to turn on the server.
Lit: The server is turned on.
Fading on and off: The server is in a reduced-power state. To wake the
server, press the power-control button or use the IMM Web interface. For
information about logging on to the IMM Web interface, see “Logging on to
the Web interface” on page 155.
v Ethernet icon LED: This LED lights the Ethernet icon.
v Ethernet activity LEDs: When any of these LEDs is lit, it indicates that the
server is transmitting to or receiving signals from the Ethernet LAN that is
connected to the Ethernet port that corresponds to that LED.
v Information LED: When this LED is lit, it indicates that a noncritical event has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the
error.
v System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the
error.
v Release latch: Slide this latch to the left to access the light path diagnostics
panel, which is behind the operator information panel.
v Locator button and locator LED: Use this LED to visually locate the server
among other servers. Press this button to turn on or turn off this LED locally. You
can use IBM Systems Director to light this LED remotely.
Light path diagnostics panel
The light path diagnostics panel is on the top of the operator information panel.
Chapter 1. The System x3650 M3 server15
To access the light path diagnostics panel, slide the blue release button on the
operator information panel to the left. Pull forward on the operator information panel
until the hinge of the panel is free of the server chassis. Then pull down on the
operator information panel, so that you can view the light path diagnostics panel
information.
Operator information
panel
Light path
diagnostics LEDs
Release latch
The following illustration shows the controls and LEDs on the light path diagnostics
panel.
Notes:
1. Do not run the server for an extended period of time while the light path
diagnostics panel is pulled out of the server.
2. Light path diagnostics LEDs remain lit only while the server is connected to
power.
Checkpoint
code display
v Remind button: This button places the system-error LED on the front panel into
Remind mode. In Remind mode, the system-error LED flashes once every 2
seconds until the problem is corrected, the server is restarted, or a new problem
occurs.
By placing the system-error LED indicator in Remind mode, you acknowledge
that you are aware of the last failure but will not take immediate action to correct
the problem. The remind function is controlled by the IMM.
v NMI button: Press this button to force a nonmaskable interrupt to the
microprocessor, if directed to do so by IBM service and support.
v Reset button: Press this button to reset the server and run the power-on
self-test (POST). You might have to use a pen or the end of a straightened paper
clip to press the button. The reset button is in the lower-right corner of the light
path diagnostics panel.
For more information about light path diagnostics, see the Problem Determinationand Service Guide on the IBM Documentation CD.
16System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Rear view
The following illustration shows the connectors on the rear of the server.
Ethernet connectors: Use either of these connectors to connect the server to a
network. When you use the Ethernet 1 connector, the network can be shared with
the IMM through a single network cable.
Power-cord connector: Connect the power cord to this connector.
USB connectors: Connect a USB device, such as USB mouse, keyboard, or other
USB device, to any of these connectors.
Serial connector: Connect a 9-pin serial device to this connector. The serial port is
shared with the integrated management module (IMM). The IMM can take control of
the shared serial port to perform text console redirection and to redirect serial
traffic, using Serial over LAN (SOL).
Video connector: Connect a monitor to this connector. The video connectors on
the front and rear of the server can be used simultaneously.
Note: The maximum video resolution is 1600 x 1200 at 75 Hz.
Systems-management Ethernet connector: Use this connector to connect the
server to a network for systems-management information control. This connector is
used only by the IMM.
The following illustration shows the LEDs on the rear of the server.
Ethernet
activity LED
Ethernet
link LED
Power-on
LED (green)
Locator LED (blue)
AC power
LED (green)
DC power
LED (green)
Power-supply
error LED (amber)
System-error
LED (amber)
Ethernet activity LEDs: When these LEDs are lit, they indicate that the server is
transmitting to or receiving signals from the Ethernet LAN that is connected to the
Ethernet port.
Ethernet link LEDs: When these LEDs are lit, they indicate that there is an active
link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for the
Ethernet port.
Chapter 1. The System x3650 M3 server17
AC power LED: Each hot-swap power supply has an ac power LED and a dc
power LED. When the ac power LED is lit, it indicates that sufficient power is
coming into the power supply through the power cord. During typical operation, both
the ac and dc power LEDs are lit. For any other combination of LEDs, see the
Problem Determination and Service Guide on the IBM Documentation CD.
IN OK power LED: Each hot-swap dc power supply has an IN OK power LED and
an OUT OK power LED. When the IN OK power LED is lit, it indicates that sufficient
power is coming into the power supply through the power cord. During typical
operation, both the IN OK and OUT OK power LEDs are lit.
DC power LED: Each hot-swap power supply has a dc power LED and an ac
power LED. When the dc power LED is lit, it indicates that the power supply is
supplying adequate dc power to the system. During typical operation, both the ac
and dc power LEDs are lit. For any other combination of LEDs, see the ProblemDetermination and Service Guide on the IBM Documentation CD.
OUT OK power LED: Each hot-swap dc power supply has an IN OK power LED
and an OUT OK power LED. When the OUT OK power LED is lit, it indicates that
the power supply is supplying adequate dc power to the system. During typical
operation, both the IN OK and OUT OK power LEDs are lit.
Power-supply error LED: When the power-supply error LED is lit, it indicates that
the power supply has failed.
Note: Power supply 1 is the default/primary power supply. If power supply 1 fails,
you must replace the power supply immediately.
System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the
error. This LED is the same as the system-error LED on the front of the server.
Locator LED: Use this LED to visually locate the server among other servers. You
can use IBM Systems Director to light this LED remotely. This LED is the same as
the system-locator LED on the front of the server.
Power-on LED: Press this button to turn the server on and off manually or to wake
the server from a reduced-power state. The states of the power-on LED are as
follows:
Off: AC power is not present, or the power supply or the LED itself has failed.
Flashing rapidly (4 times per second): The server is turned off and is not
ready to be turned on. The power-control button is disabled. This will last
approximately 20 to 40 seconds.
Note: Approximately 40 seconds after the server is connected to ac power, the
power-control button becomes active.
Flashing slowly (once per second): The server is turned off and is ready to be
turned on. You can press the power-control button to turn on the server.
Lit: The server is turned on.
Fading on and off: The server is in a reduced-power state. To wake the server,
press the power-control button or use the IMM Web interface. For information
about logging on to the IMM Web interface, see “Logging on to the Web
interface” on page 155.
18System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Power-supply LEDs
The following illustration shows the power-supply LEDs on the rear of the server.
For more information about solving power-supply problems, see the ProblemDetermination and Service Guide.
The following table describes the problems that are indicated by various
combinations of the power-supply LEDs and the power-on LED on the operator
information panel and suggested actions to correct the detected problems.
Chapter 1. The System x3650 M3 server19
Table 2. Power-supply LEDs
AC power-supply LEDs
DescriptionActionNotesACDCError
OffOffOffNo ac power to
the server or a
problem with the
ac power source
OffOffOnNo ac power to
the server or a
problem with the
ac power source
and the power
supply had
detected an
internal problem
OffOnOffFaulty power
supply
OffOnOnFaulty power
supply
OnOffOffPower supply not
fully seated,
faulty system
board, or faulty
power supply
OnOff or
Flashing
OnOnOffNormal operation
OnOnOnPower supply is
OnFaulty power
supply
faulty but still
operational
1. Check the ac power to the server.
2. Make sure that the power cord is
connected to a functioning power
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
1. Replace the power supply.
2. Make sure that the power cord is
connected to a functioning power
source.
Replace the power supply.
Replace the power supply.
1. (Trained service technician only)
Reseat the power supply.
2. If a power channel error LED on the
system board is not lit, replace the
power-supply (see the documentation
that comes with the power supply for
instructions).
3. If a power channel error LED on the
system board is lit, (trained service
technician only) replace the system
board.
Replace the power supply.
Replace the power supply.
This is a normal
condition when no
ac power is present.
This happens only
when a second
power supply is
providing power to
the server.
Typically indicates
that a power supply
is not fully seated.
The following table describes the problems that are indicated by various
combinations of the power-supply LEDs on a dc power supply and suggested
actions to correct the detected problems.
20System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
DC power-supply LEDs
DescriptionActionNotesIN OKOUT OKError (!)
OnOnOffNormal operation
OffOffOffNo dc power to the
server or a problem
with the dc power
source.
OffOffOnNo dc power to the
server or a problem
with the dc power
source and the
power-supply had
detected an internal
problem.
OffOnOffFaulty
power-supply
OffOnOnFaulty
power-supply
OnOffOffPower-supply not
fully seated, faulty
system board, or
faulty power-supply
OnOffOnFaulty
power-supply
OnOnOnPower-supply is
faulty but still
operational
1. Check the dc power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the error
remains, check the
power-supply LEDs.
4. Replace the power-supply.
v Make sure that the power cord
is connected to a functioning
power source.
v Replace the power supply
(see the documentation that
comes with the power supply
for instructions).
Replace the power supply.
Replace the power supply.
1. (Trained service technician
only) Reseat the power
supply.
2. If a power channel error LED
on the system board is not lit,
replace the power-supply
(see the documentation that
comes with the power supply
for instructions).
3. If a power channel error LED
on the system board is lit,
(trained service technician
only) replace the system
board.
Replace the power supply.
Replace the power supply.
This is a normal
condition when no dc
power is present.
This happens only
when a second power
supply is providing
power to the server.
Typically indicates a
power-supply is not
fully seated.
Server power features
When the server is connected to a power source but is not turned on, the operating
system does not run, and all core logic except for the integrated management
module (IMM) is shut down; however, the server can respond to requests from the
IMM, such as a remote request to turn on the server. The power-on LED flashes to
indicate that the server is connected to power but is not turned on.
Chapter 1. The System x3650 M3 server21
Turning on the server
Approximately 3 minutes after the server is connected to power, the power-control
button becomes active, and one or more fans might start running to provide cooling
while the server is connected to power. You can turn on the server and start the
operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
v If a power failure occurs while the server is turned on, the server will restart
automatically when power is restored.
v If your operating system supports the Wake on LAN feature, the Wake on LAN
feature can turn on the server.
For 32-bit operating systems only: Some memory is reserved for various system
resources and is unavailable to the operating system. The amount of memory that
is reserved for system resources depends on the operating system, the
configuration of the server, and the configured PCI options.
Turning off the server
When you turn off the server and leave it connected to power, the server can
respond to requests from the IMM, such as a remote request to turn on the server.
While the server remains connected to power, one or more fans might continue to
run. To remove all power from the server, you must disconnect it from the power
source.
Important: To view the error LEDs on the system board, leave the server
connected to a power source.
Some operating systems require an orderly shutdown before you turn off the server.
See your operating-system documentation for information about shutting down the
operating system.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
The server can be turned off in any of the following ways:
v You can turn off the server from the operating system, if your operating system
supports this feature. After an orderly shutdown of the operating system, the
server will be turned off automatically.
v You can press the power-control button to start an orderly shutdown of the
operating system and turn off the server, if your operating system supports this
feature.
22System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
v If the operating system stops functioning, you can press and hold the
power-control button for more than 4 seconds to turn off the server.
v The IMM can turn off the server as an automatic response to a critical system
failure.
v You can turn off the server through a request from the IMM.
Chapter 1. The System x3650 M3 server23
24System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Chapter 2. Installing optional devices
This chapter provides detailed instructions for installing optional hardware devices in
the server.
In addition to the instructions in this chapter for installing optional hardware devices,
updating firmware and device drivers, and completing the installation, IBM Business
Partners must also complete the steps in “Instructions for IBM Business Partners.”
Important: To help ensure that the devices that you install work correctly and do
not introduce problems, observe the following precautions:
1. Make sure that the server and the installed firmware levels support the devices
that you are installing. If necessary, update the UEFI and IMM firmware and any
other firmware that is stored on the system boards. For information about where
firmware is stored in the server, see Chapter 6, “Configuration information and
instructions,” in the Problem Determination and Service Guide. For a list of
supported optional devices for the server, see http://www.ibm.com/systems/info/
x86servers/serverproven/compat/us/.
2. Before you install optional hardware devices, make sure that the server is
working correctly. Start the server and make sure that the operating system
starts, if an operating system is installed, or that a 19990305 error code is
displayed, indicating that an operating system was not found but the server is
otherwise working correctly. If the server is not working correctly, see the
Problem Determination and Service Guide for information about how to run
diagnostics.
3. Follow the installation procedures in this chapter and use the correct tools.
Incorrectly installed devices can cause system failures because of damaged
pins in sockets or connectors, loose cabling, or loose components.
4. Use the best practices to apply current firmware and device-driver updates for
the server and optional devices. To download the IBM System x FirmwareUpdate Best Practices document, go to http://www.ibm.com/support/entry/portal/
docdisplay?brand=50000020&lndocid=MIGR-5082923. Additional hints and tips
are available from the following sites:
v IBM support: http://www.ibm.com/supportportal/
v System x configuration tools: http://www.ibm.com/systems/x/hardware/
configtools.html
Instructions for IBM Business Partners
In addition to the instructions in this chapter for installing optional hardware devices,
updating firmware and device drivers, and completing the installation, IBM Business
Partners must also complete the following steps:
1. Before you configure a server for a customer, complete the Solution Assurance
checklist at http://w3.ibm.com/support/assure/assur30i.nsf/webindex/sa294/.
2. After you have confirmed that the server starts correctly and recognizes the
newly installed devices and that no error LEDs are lit, run the Dynamic System
Analysis (DSA) stress tests. For information about using DSA, see the ProblemDetermination and Service Guide.
3. Shut down and restart the server multiple times to ensure that the server is
correctly configured and functions correctly with the newly installed devices.
5. To ship the server, repackage it in the original undamaged packing material and
observe IBM procedures for shipping.
Support information for IBM Business Partners is available at http://www.ibm.com/
partnerworld/.
Server components
The following illustrations show the major components in the server.
26System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Note: The illustrations in this document might differ slightly from your hardware.
Chapter 2. Installing optional devices27
System-board internal connectors
The following illustration shows the internal connectors on the system board.
28System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
System-board external connectors
The following illustration shows the external input/output connectors on the system
board.
Chapter 2. Installing optional devices29
System-board switches and jumpers
The following illustration shows the location and description of the switches and
jumpers.
Note: If there is a clear protective sticker on the top of the switch blocks, you must
remove and discard it to access the switches.
The default positions for the UEFI and the IMM recovery jumpers are pins 1 and 2.
UEFI boot recovery
jumper (J29)
IMM recovery jumper
(J147)
1
3
2
1
2
3
The following table describes the jumpers on the system board.
Table 3. System board jumpers
Jumper
number
J29UEFI boot
30System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
SW3 switch blockSW4 switch block
Jumper
nameJumper setting
recovery
jumper
v Pins 1 and 2: Normal (default) Loads the primary server
firmware ROM page.
v Pins 2 and 3: Loads the secondary (backup) server firmware
ROM page.
Table 3. System board jumpers (continued)
Jumper
number
J147IMM
Jumper
nameJumper setting
recovery
jumper
v Pins 1 and 2: Normal (default) Loads the primary IMM
firmware ROM page.
v Pins 2 and 3: Loads the secondary (backup) IMM firmware
ROM page.
Notes:
1. If no jumper is present, the server responds as if the pins are set to 1 and 2.
2. Changing the position of the UEFI boot recovery jumper from pins 1 and 2 to pins 2 and
3 before the server is turned on alters which flash ROM page is loaded. Do not change
the jumper pin position after the server is turned on. This can cause an unpredictable
problem.
The following illustration shows the jumper settings for switch blocks SW3 and SW4
on the system board.
Table 4 on page 32 and Table 5 on page 32 describe the function of each switch on
SW3 and SW4 switch blocks on the system board.
1234 1234
OffOff
SW3 switch blockSW4 switch block
Chapter 2. Installing optional devices31
Table 4. System board switch block 3, switches1-4
Switch
numberDefault valueSwitch description
1OffClear CMOS memory. When this switch is toggled to On, it clears the data in
CMOS memory, which clears the power-on password.
2OffTrusted Platform Module (TPM) physical presence. Turning this switch to the on
position indicates a physical presence to the TPM.
3OffReserved.
4OffReserved.
Table 5. System board switch block 4, switches1-4
Switch
numberDefault valueSwitch description
1OffPower-on password override. Changing the position of this switch bypasses the
power-on password check the next time the server is turned on and starts the
Setup utility so that you can change or delete the power-on password. You do not
have to move the switch back to the default position after the password is
overridden.
Changing the position of this switch does not affect the administrator password
check if an administrator password is set.
See “Passwords” on page 148 for additional information about the power-on
password.
2OffPower-on override. When this switch is toggled to On and then to Off, you force a
power-on which overrides the power-on and power-off button on the server and
they become nonfunctional.
3OffForced power permission overrides the IMM power-on checking process. (Trained
service technician only)
4OffReserved.
Important:
1. Before you change any switch settings or move any jumpers, turn off the server;
then, disconnect all power cords and external cables. (Review the information in
“Safety” on page vii, “Installation guidelines” on page 37, “Handling
static-sensitive devices” on page 39, and “Turning off the server” on page 22.)
2. Any system-board switch or jumper blocks that are not shown in the illustrations
in this document are reserved.
32System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
System-board LEDs
The following illustration shows the light-emitting diodes (LEDs) on the system
board.
Note: Error LEDs remain lit only while the server is connected to power.
System pulse LEDs
The following LEDs are on the system board and monitor the system power-on and
power-off sequencing and boot progress (see “System-board LEDs” for the location
of these LEDs).
Table 6. System-pulse LEDs
LEDDescriptionAction
Enclosure manager heartbeat Indicates the status of
power-on and power-off
sequencing.
When the server is
connected to power, this LED
flashes slowly to indicate that
the enclosure manager is
working correctly.
Chapter 2. Installing optional devices33
(Trained service technician
only) If the server is
connected to power and the
LED is not flashing, replace
the system board.
Table 6. System-pulse LEDs (continued)
LEDDescriptionAction
IMM heartbeatIndicates the status of the
boot process of the IMM.
When the server is
connected to power this LED
flashes quickly to indicate
that the IMM code is loading.
When the loading is
complete, the LED stops
flashing briefly and then
flashes slowly to indicate that
the IMM if fully operational
and you can press the
power-control button to start
the server.
System-board optional device connectors
The following illustration shows the connectors on the system board for
user-installable options.
If the LED does not begin
flashing within 30 seconds of
when the server is connected
to power, complete the
following steps:
1. (Trained service
technician only) Use the
IMM recovery jumper to
recover the firmware (see
Table 3 on page 30).
2. (Trained service
technician only) Replace
the system board.
34System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
SAS riser-card connectors and LEDs
The following illustrations show the connectors and LEDs on the SAS riser-cards.
Note: Error LEDs remain lit only while the server is connected to power.
A 16-drive-capable model server contains the riser card that is shown in the
following illustration.
USB hypervisor
connector
PCI Express SAS
controller connector
SAS controller
error LED
SAS riser
card
A tape-enabled model server contains the riser card that is shown in the following
illustration.
PCI Express SAS
USB hypervisor
connector
USB
tape
signal
controller connector
SATA tape signal
Tape drive
power
SAS controller
error LED
SAS riser card
(tape-enabled model server)
Chapter 2. Installing optional devices35
PCI riser-card adapter connectors
The following illustration shows the connectors on the PCI riser card for
user-installable PCI adapters.
Adapter
PCI riser-card assembly LEDs
The following illustration shows the light-emitting diodes (LEDs) on the PCI
riser-card assembly.
Note: Error LEDs remain lit only while the server is connected to power.
Upper PCI slot error LED
(Adaptor card error LED)
PCI
riser-card
assembly
Adapter
connectors
Lower PCI slot
error LED
36System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Installation guidelines
Attention:Static electricity that is released to internal server components when
the server is powered-on might cause the system to halt, which might result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when removing or installing a hot-swap
device.
Before you install optional devices, read the following information:
v Read the safety information that begins on page vii, the guidelines in “Working
inside the server with the power on” on page 38, and “Handling static-sensitive
devices” on page 39. This information will help you work safely.
v When you install your new server, take the opportunity to download and apply
the most recent firmware updates. This step will help to ensure that any known
issues are addressed and that your server is ready to function at maximum levels
of performance. To download firmware updates for your server, complete the
following steps:
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers.
4. Click System x3650 M3 to display the matrix of downloadable files for the
server.
For additional information about tools for updating, managing, and deploying
firmware, see the System x and xSeries Tools Center at
http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
v Before you install optional hardware, make sure that the server is working
correctly. Start the server, and make sure that the operating system starts, if an
operating system is installed, or that a 19990305 error code is displayed,
indicating that an operating system was not found but the server is otherwise
working correctly. If the server is not working correctly, see the ProblemDetermination and Service Guide on the IBM System x Documentation CD for
diagnostic information.
v Observe good housekeeping in the area where you are working. Place removed
covers and other parts in a safe place.
v If you must start the server while the cover is removed, make sure that no one is
near the server and that no tools or other objects have been left inside the
server.
v Do not attempt to lift an object that you think is too heavy for you. If you have to
lift a heavy object, observe the following precautions:
– Make sure that you can stand safely without slipping.
– Distribute the weight of the object equally between your feet.
– Use a slow lifting force. Never move suddenly or twist when you lift a heavy
object.
– To avoid straining the muscles in your back, lift by standing or by pushing up
with your leg muscles.
v Make sure that you have an adequate number of properly grounded electrical
outlets for the server, monitor, and other devices.
v Back up all important data before you make changes to disk drives.
v Have a small flat-blade screwdriver available.
Chapter 2. Installing optional devices37
v To view the error LEDs on the system board and internal components, leave the
server connected to power.
v You do not have to turn off the server to install or replace hot-swap fans,
redundant hot-swap ac power supplies, or hot-plug Universal Serial Bus (USB)
devices. However, you must turn off the server before you perform any steps that
involve removing or installing adapter cables or non-hot-swap optional devices or
components.
v Blue on a component indicates touch points, where you can grip the component
to remove it from or install it in the server, open or close a latch, and so on.
v Orange on a component or an orange label on or near a component indicates
that the component can be hot-swapped, which means that if the server and
operating system support hot-swap capability, you can remove or install the
component while the server is running. (Orange can also indicate touch points on
hot-swap components.) See the instructions for removing or installing a specific
hot-swap component for any additional procedures that you might have to
perform before you remove or install the component.
v When you are finished working on the server, reinstall all safety shields, guards,
labels, and ground wires.
v For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
System reliability guidelines
To help ensure proper system cooling and system reliability, make sure that the
following requirements are met:
v Each of the drive bays has a drive or a filler panel and electromagnetic
compatibility (EMC) shield installed in it.
v If the server has redundant power, each of the power-supply bays has a power
supply installed in it.
v There is adequate space around the server to allow the server cooling system to
work properly. Leave approximately 50 mm (2.0 in.) of open space around the
front and rear of the server. Do not place objects in front of the fans. For proper
cooling and airflow, replace the server cover before you turn on the server.
Operating the server for extended periods of time (more than 30 minutes) with
the server cover removed might damage server components.
v You have followed the cabling instructions that come with optional adapters.
v You have replaced a failed fan within 48 hours.
v You have replaced a hot-swap fan within 30 seconds of removal.
v You have replaced a hot-swap drive within 2 minutes of removal.
v You do not operate the server without the air baffles installed. Operating the
server without the air baffles might cause the microprocessors to overheat.
v Microprocessor 2 air baffle and DIMM air baffle are installed.
v The light path diagnostics panel is not pulled out of the server.
Working inside the server with the power on
Attention:Static electricity that is released to internal server components when
the server is powered-on might cause the server to halt, which might result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when you work inside the server with the
power on.
38System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
The server supports hot-plug, hot-add, and hot-swap devices and is designed to
operate safely while it is turned on and the cover is removed. Follow these
guidelines when you work inside a server that is turned on:
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts
before working inside the server; do not wear cuff links while you are working
inside the server.
v Do not allow your necktie or scarf to hang inside the server.
v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist
watches.
v Remove items from your shirt pocket, such as pens and pencils, that might fall
into the server as you lean over it.
v Avoid dropping any metallic objects, such as paper clips, hairpins, and screws,
into the server.
Handling static-sensitive devices
Attention:Static electricity can damage the server and other electronic devices.
To avoid damage, keep static-sensitive devices in their static-protective packages
until you are ready to install them.
To reduce the possibility of damage from electrostatic discharge, observe the
following precautions:
v Limit your movement. Movement can cause static electricity to build up around
you.
v The use of a grounding system is recommended. For example, wear an
electrostatic-discharge wrist strap, if one is available. Always use an
electrostatic-discharge wrist strap or other grounding system when working inside
the server with the power on.
v Handle the device carefully, holding it by its edges or its frame.
v Do not touch solder joints, pins, or exposed circuitry.
v Do not leave the device where others can handle and damage it.
v While the device is still in its static-protective package, touch it to an unpainted
metal surface on the outside of the server for at least 2 seconds. This drains
static electricity from the package and from your body.
v Remove the device from its package and install it directly into the server without
setting down the device. If it is necessary to set down the device, put it back into
its static-protective package. Do not place the device on the server cover or on a
metal surface.
v Take additional care when handling devices during cold weather. Heating reduces
indoor humidity and increases static electricity.
Chapter 2. Installing optional devices39
Internal cable routing and connectors
The following illustration shows the internal routing and connectors for the two SAS
signal cables (in server models with eight SAS drive bays).
Notes:
1. To connect the SAS signal cables, make sure that you first connect the signal
cable, and then the power cable and signal cable.
2. To disconnect the SAS signal cables, make sure that you first disconnect the
power cable, and then the signal cable and configuration cable.
The SATA cable is a combination power and signal cable with a shared connector
on both ends. The following illustration shows the internal routing and connector for
the SATA cable.
40System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
The following illustration shows the internal routing and connector for the operator
information panel cable.
The following illustration shows the internal routing and connector for the USB/video
cable.
Note: The USB cable is routed under the video cable and then both the USB and
video cables are routed under the cable retention tab and the top cover latch
receptacle.
The following illustration shows the internal routing for the configuration cable.
Chapter 2. Installing optional devices41
The following illustrations show the internal routing for the SAS hard disk drive
backplane cables (for a 16 hard disk drive model).
42System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Chapter 2. Installing optional devices43
Removing the cover
The following illustration shows how to remove the cover.
Important: Before you install optional hardware, make sure that the server is
working correctly. Start the server, and make sure that the operating system starts,
if an operating system is installed, or that a 19990305 error code is displayed,
indicating that an operating system was not found but the server is otherwise
working correctly. If the server is not working correctly, see the ProblemDetermination and Service Guide for diagnostic information.
Cover-release
latch
To remove the cover, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. If you are planning to view the error LEDs that are on the system board and
components, leave the server connected to power and go directly to step 4.
3. If you are planning to install or remove a microprocessor, memory module, PCI
adapter, battery, or other non-hot-swap optional device, turn off the server and
all attached devices and disconnect all external cables and power cords (see
“Turning off the server” on page 22).
4. Press down on the left and right side latches and slide the server out of the rack
enclosure until both slide rails lock.
Note: You can reach the cables on the rear of the server when the server is in
the locked position.
5. Press the blue latch 1 on the end of the cover-release latch and lift the
cover-release latch 2. Slide the cover toward the rear 3 and lift the cover off
the server. Set the cover aside.
Attention:For proper cooling and airflow and to avoid damaging server
components, replace the cover before you turn on the server. If you operate the
server for extended periods of time (over 30 minutes) with the cover removed, the
IMM turns off the server.
44System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Removing a PCI riser-card assembly
The server comes with one riser-card assembly (with option to add one more) that
each contain two PCI Express x8 connectors. You can replace a PCI Express
riser-card assembly with a riser-card assembly that contains one PCI Express Gen
2 x16 connector or that contains two PCI-X 64-bit 133 MHz connectors. See
http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of riser-card
assemblies that you can use with the server.
PCI riser-card
assembly 2
PCI riser-card
assembly 1
To remove the riser-card assembly, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and peripheral devices, and disconnect the power cord and
all external cables.
3. Remove the cover (see “Removing the cover” on page 44).
4. Grasp the assembly at the front tab and rear edge and lift it to remove it from
the server. Place the riser-card assembly on a flat, static-protective surface.
Chapter 2. Installing optional devices45
Installing a PCI riser-card assembly
To install a PCI riser-card assembly, complete the following steps.
Note: The illustrations in this document might differ slightly from your hardware.
PCI riser
connector 2
PCI riser-card
PCI riser-card
assembly 2
assembly 2
PCI riser-card
PCI riser-card
assembly 1
assembly 1
Alignment
slots
Alignment
brackets
PCI riser
connector 1
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Make sure that the server and all peripheral devices are turned off and that the
power cords and all external cables are disconnected.
3. Reinstall any adapters and reconnect any internal cables that you removed in
other procedures.
4. Align the PCI riser-card assembly with the selected PCI riser-card connector on
the system board:
v PCI riser-card connector 1: Carefully fit the two alignment slots on the side of
the assembly onto the two alignment brackets in the side of the chassis.
v PCI riser-card connector 2: Carefully align the bottom edge (the contact
edge) of the riser-card assembly with the PCI riser-card connector on the
system board.
5. Press down on the assembly. Make sure that the riser-card assembly is fully
seated in the riser-card connector on the system board.
If you have other devices to install, do so now. Otherwise, go to “Completing the
installation” on page 139.
46System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Removing the microprocessor 2 air baffle
When you work with some optional devices, you must first remove the
microprocessor 2 air baffle to access certain components. The following illustration
shows how to remove the microprocessor 2 air baffle.
To remove the microprocessor 2 air baffle, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 22).
3. Remove the cover (see “Removing the cover” on page 44).
4. Remove PCI riser-card assembly 2 if one is installed (see “Removing a PCI
riser-card assembly” on page 45).
5. Grasp the top of the air baffle and lift the air baffle out of the server.
Attention:For proper cooling and airflow, replace all air baffles before you
turn on the server. Operating the server with any air baffle removed might
damage server components.
Chapter 2. Installing optional devices47
Installing the microprocessor 2 air baffle
To install the microprocessor 2 air baffle, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Make sure that the server and peripheral devices are turned off (see “Turning
off the server” on page 22) and that all power cords and external cables are
disconnected.
3. Remove the cover (see “Removing the cover” on page 44).
4. Align the tab on the left side of the microprocessor 2 air baffle with the slot in
the right side of the power-supply cage.
5. Lower the microprocessor 2 air baffle into the server. Make sure that the pin on
the end of the air baffle is inserted into the hole on the system board (see the
illustration).
Attention:For proper cooling and airflow, replace all air baffles before you
turn on the server. Operating the server with any air baffle removed might
damage server components.
48System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Removing the DIMM air baffle
When you work with some optional devices, you must first remove the DIMM air
baffle to access certain components or connectors on the system board. The
following illustration shows how to remove the DIMM air baffle.
PCI riser-card
assembly 1
DIMM air baffle
To remove the DIMM air baffle, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 22).
3. Remove the cover (see “Removing the cover” on page 44).
4. Remove PCI riser-card assembly 1, if needed (see “Removing a PCI riser-card
assembly” on page 45).
5. Place your fingers under the front and back of the top of the air baffle; then, lift
the air baffle out of the server.
Attention:For proper cooling and airflow, replace all air baffles before you
turn on the server. Operating the server with any air baffle removed might
damage server components.
Chapter 2. Installing optional devices49
Installing the DIMM air baffle
The following illustration shows how to install the DIMM air baffle.
PCI riser-card
assembly 1
DIMM air baffle
To install the DIMM air baffle, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Make sure that the server and peripheral devices are turned off (see “Turning
off the server” on page 22) and that all power cords and external cables are
disconnected.
3. Remove the cover (see “Removing the cover” on page 44).
4. Make sure that PCI riser-card assembly 1 is removed (see “Removing a PCI
riser-card assembly” on page 45).
5. Align the DIMM air baffle with the DIMMs and the back of the fans.
6. Lower the air baffle into place.
7. Install PCI riser-card assembly 1, if needed (see “Installing a PCI riser-card
assembly” on page 46.
Attention:For proper cooling and airflow, replace all air baffles before you turn on
the server. Operating the server with any air baffle removed might damage server
components.
50System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Installing the full-length-adapter bracket
If you are installing a full-length adapter in the upper riser-card PCI slot, you must
first install the full-length-adapter bracket in the end of the riser-card assembly.
To install the full-length-adapter bracket, complete the following steps:
1. Orient the riser-card assembly as shown.
2. Remove the full-length-adapter bracket from the storage location.
a. Press the bracket tab 3 and slide the bracket toward the end of the
riser-card assembly.
b. Push the bracket out of the storage location on the riser-card assembly.
3. Align the bracket with the end of the riser-card assembly as shown.
4. Place the two hooks 1 in the two openings 2 in the end of the riser-card
assembly.
5. Press the bracket tab 3 and slide the bracket to the right until it clicks into
place.
6. Return to the adapter-installation instructions.
Storing the full-length-adapter bracket
If you are removing a full-length adapter in the upper riser-card PCI slot and will
replace it with a shorter adapter or no adapter, you must remove the
full-length-adapter bracket from the end of the riser-card assembly and return the
bracket to its storage location.
To remove and store the full-length-adapter bracket, complete the following steps:
1. Press the bracket tab 3 and slide the bracket to the left until the bracket falls
free of the riser-card assembly.
2. Align the bracket with the storage location on the riser-card assembly as shown.
3. Place the two hooks 1 in the two openings 2 in the storage location on the
riser-card assembly.
Chapter 2. Installing optional devices51
4. Press the bracket tab 3 and slide the bracket toward the
expansion-slot-opening end of the assembly until the bracket clicks into place.
5. Return to “Installing a PCI adapter” or “Installing a PCI riser-card assembly” on
page 46, as applicable.
Installing a PCI adapter
The following illustration shows the PCI adapter expansion slots from the rear of the
server.
The following notes describe the types of adapters that the server supports and
other information that you must consider when you install an adapter:
v Locate the documentation that comes with the adapter and follow those
instruction in addition to the instructions in this section. If you have to change
switch settings or jumper settings on the adapter, follow the instructions that
come with the adapter.
v To ensure that a ServeRAID-10i, ServeRAID-10is, or ServeRAID-10M adapter
works correctly in your UEFI-based server, make sure that the adapter firmware
is at the latest level.
Important: Some cluster solutions require specific code levels or coordinated
code updates. If the device is part of a cluster solution, verify that the latest level
of code is supported for the cluster solution before you update the code.
v Some high performance video adapters are supported by your server. See
http://www.ibm.com/servers/eserver/serverproven/compat/us/ for more
information.
v The following notes describe important information about the NVIDIA video
adapter that comes preinstalled in some server models:
– Do not set the maximum digital video resolution above 1600 x 1200 at 75 Hz
for an LCD monitor. This is the highest resolution that is supported for an
optional video adapter in the server.
– Any high-definition video-out connector or stereo connector on an optional
video adapter is not supported.
v A PCI Express Gen 2 x16 riser card can support only one adapter.
v A PCI Express Gen 2 x8 riser card and a PCI-X riser card can each support two
adapters.
v The expansion slots in the PCI riser cards accommodate the various form factors
of the non-hot-plug adapters as follows:
– Expansion slot 1: Full-height, full-length
– Expansion slot 2: Low-profile with standard bracket
– Expansion slot 3: Full-height, full-length
– Expansion slot 4: Full-height, half-length
Note: If you are installing x3650 M3 PCI Express Gen 2 x8 riser card (part
number 59Y3818), you cannot install any adaptor in slot 1.
52System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
If you install a different supported riser-card assembly, the supported adapter
types might be different. For a list of supported riser-card assemblies, see
http://www.ibm.com/servers/eserver/serverproven/compat/us/.
v The system scans devices in the following order, if you have not changed the
default boot precedence:
– Video Unified Extensible Firmware Interface (UEFI) (fixed)
– System board Ethernet 1 PXE (fixed)
– System board Ethernet 2 PXE (fixed)
– System board SAS (or RAID)
The following illustration shows the adapter connectors on the PCI riser-card
assembly.
Adapter
PCI
riser-card
assembly
Adapter
connectors
To install a PCI adapter, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 22).
3. Remove the cover (see “Removing the cover” on page 44).
4. Determine which expansion slot you will use for the adapter.
5. If you are installing an adapter in PCI expansion slot 1 or 2, remove PCI
riser-card assembly 1; if you are installing an adapter in PCI expansion slot 3
or 4, remove PCI riser-card assembly 2. See “Removing a PCI riser-card
assembly” on page 45.
6. Slide the expansion-slot cover out of the PCI riser-card assembly expansion
slot.
Chapter 2. Installing optional devices53
Expansion-slot
Adapter
cover
PCI
riser-card
assembly
7. Install the adapter:
a. If the adapter is a full-length adapter for the upper expansion slot in the
riser card, remove the full-length-adapter bracket from underneath the top
of the riser-card assembly and insert it in the end of the upper expansion
slot of the riser-card assembly. See “Installing the full-length-adapter
bracket” on page 51 for instructions.
b. Align the adapter with the adapter connector on the riser-card and the
guide on the external end of the PCI riser-card assembly.
c. Press the adapter firmly into the adapter connector on the riser card.
8. Connect any required cables to the adapter.
Attention:
v When you route cables, do not block any connectors or the ventilated space
around any of the fans.
v Make sure that cables are not routed on top of components that are under
the PCI riser-card assembly.
v Make sure that cables are not pinched by the server components.
9. Align the PCI riser-card assembly with the selected PCI riser-card connector
on the system board.
54System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
PCI riser
connector 2
PCI riser-card
PCI riser-card
assembly 2
assembly 2
PCI riser-card
PCI riser-card
assembly 1
assembly 1
Alignment
slots
Alignment
brackets
PCI riser
connector 1
v PCI riser-card connector 1: Carefully fit the two alignment slots on the side
of the assembly onto the two alignment brackets in the side of the chassis;
align the rear of the assembly with the guides on the rear of the server.
v PCI riser-card connector 2: Carefully align the bottom edge (the contact
edge) of the riser-card assembly with the PCI riser-card connector on the
system board; align the rear of the assembly with the guides on the rear of
the server.
10. Press down on the assembly. Make sure that the riser-card assembly is fully
seated in the PCI riser-card connector on the system board.
11. Perform any configuration tasks that are required for the adapter.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Chapter 2. Installing optional devices55
Removing a PCI adapter
To remove an adapter from a PCI riser-card assembly, complete the following steps.
Adapter
Expansion-slot
cover
PCI
riser-card
assembly
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 22).
3. Press down on the left and right side rack latches and slide the server out of the
rack enclosure until both slide rails lock; then, remove the cover (see “Removing
the cover” on page 44).
PCI riser-card
assembly 2
PCI riser-card
assembly 1
4. Remove the PCI riser-card assembly that contains the adapter (see “Removing
a PCI riser-card assembly” on page 45).
5. Disconnect any cables from the adapter (make note of the cable routing, in case
you reinstall the adapter later).
56System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
6. Carefully grasp the adapter by its top edge or upper corners, and pull the
adapter from the PCI expansion slot.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Installing an IBM Virtual Media Key
The optional IBM Virtual Media Key enables the IMM remote presence and
blue-screen capture capability. This feature provides graphical console redirection
with remote keyboard and mouse interaction, plus remote diskette and CD/DVD
drive support.
To install a virtual media key, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 22).
3. Remove the cover (see “Removing the cover” on page 44).
4. Align the mounting bracket on the rear of the virtual media key with the
mounting tab and slide it down the tab onto the virtual medial key connector on
the system board. Press the virtual media key down into the connector until it is
firmly seated on the system board.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Chapter 2. Installing optional devices57
Installing a hard disk drive
The following notes describe the type of hard disk drives that the server supports
and other information that you must consider when you install a drive. For a list of
supported drives, see http://www.ibm.com/servers/eserver/serverproven/compat/us/.
Important: Do not install a SCSI hard disk drive in this server.
v Locate the documentation that comes with the hard disk drive and follow those
instructions in addition to the instructions in this chapter.
v The server supports eight 2.5-inch hot-swap or simple-swap hard disk drives
installed on Ultra-Slim hard disk drive trays. An optional 8-drive-bay kit is
available for 16-drive-capable server models. For a list of supported 2.5-inch hard
disk drives, see http://www.ibm.com/servers/eserver/serverproven/compat/us/.
v All hot-swap drives in the server should have the same throughput speed rating.
Using hard disk drives with different speed ratings will cause all drives to operate
at the throughput speed of the slowest drive.
v The ID that is assigned to each bay is printed on the front of the server, above
the drive bay.
The following illustration shows how to install a hot-swap hard disk drive.
Latch
Handle
Filler panel handle
To install a drive in a hot-swap bay, complete the following steps.
Attention:To maintain proper system cooling, do not operate the server for more
than 10 minutes without either a drive or a filler panel installed in each bay.
1. Read the safety information that begins on page vii, “Installation guidelines” on
page 37, and “Handling static-sensitive devices” on page 39.
2. Remove the filler panel from one of the empty hot-swap bays: Grasp the filler
panel handle and pull the filler panel away from the server.
3. Install the hard disk drive in the hot-swap bay:
a. Orient the drive as shown in the illustration.
b. Make sure that the tray handle is open.
c. Align the drive assembly with the guide rails in the bay.
d. Gently push the drive assembly into the bay until the drive stops 1.
e. Push the tray handle to the closed (locked) position 2.
f. If the system is turned on, check the hard disk drive status LED to verify that
the hard disk drive is operating correctly.
58System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
After you install a hard disk drive, the green activity LED flashes as the disk
spins up. The amber LED turn off after about 1 minute. If the new drive starts
to rebuild, the amber LED flashes slowly and the green activity LED remains
lit during the rebuild process. If the amber LED remains lit, see the ProblemDetermination and Service Guide on the IBM Documentation CD for hard
disk drive problem solutions.
Note: You might have to reconfigure the disk arrays after you install hard disk
drives. See the RAID documentation on the IBM ServeRAID Support CD for
information about RAID controllers.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Removing a hard disk drive
Latch
Handle
To remove a hot-swap hard disk drive, complete the following steps:
1. Read the safety information that begins on page vii, “Installation guidelines” on
page 37, and “Handling static-sensitive devices” on page 39.
2. Press up on the release latch at the top of the drive front.
3. Move the handle on the drive to the open position (perpendicular to the drive).
4. Pull the hot-swap drive assembly out of the bay approximately 25 mm (1 in.).
Wait approximately 45 seconds while the drive spins down before you remove
the drive assembly completely from the bay.
Note: You might have to reconfigure the disk arrays after you remove a hard
disk drive. See the RAID documentation on the IBM ServeRAID Support CD for
information about RAID controllers.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Installing a simple-swap hard disk drive
Locate the documentation that comes with the hard disk drive and follow those
instructions in addition to the instructions in this section.
Simple-swap models do not support the SAS hot-swap backplane or the SAS
riser-card.
Chapter 2. Installing optional devices59
For information about the type of hard disk drive that the server supports and other
information that you must consider when installing a hard disk drive, see the
Installation and User’s Guide on the IBM Documentation CD.
Important: Do not install a SCSI hard disk drive in this server.
To install a drive in a simple-swap bay, complete the following steps.
Attention:To maintain proper system cooling, do not operate the server for more
than 10 minutes without either a drive or a filler panel installed in each bay.
1. Remove the drive filler panel from the front of the server.
2. Orient the drive as shown in the illustration.
3. Align the drive assembly with the guide rails in the bay.
4. Gently push the drive assembly into the bay until the drive stops.
Note: You might have to reconfigure the disk arrays after you install hard disk
drives. See the RAID documentation on the IBM ServeRAID Support CD for
information about RAID controllers.
60System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
Removing a simple-swap hard disk drive
Attention:To maintain proper system cooling, do not operate the server for more
than 10 minutes without either a drive or a filler panel installed in each bay.
To remove a hard disk drive from a simple-swap bay, complete the following steps.
1. Read the safety information that begins on page vii, “Installation guidelines” on
page 37, and “Handling static-sensitive devices” on page 39.
2. Remove the drive filler panel.
3. Push drive into the bay until it latches into place.
4. Replace the drive filler panel.
Installing a SAS/SATA 4 Pac HDD upgrade option
If the server is a 16-drive-capable model with four hard disk drive bays installed,
you can install an IBM System x3650 M3 Hot-swap SAS/SATA 4 Pac HDD upgrade
option. See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of
supported optional devices. To order a SAS/SATA 4 Pac HDD upgrade option,
contact your IBM marketing representative or authorized reseller.
Note: You need to install the SAS/SATA 4 Pac HDD upgrade option first in order to
upgrade to either SAS/SATA 16 Pac HDD system or a 8 Pac HDD + tape system.
The SAS/SATA 4 Pac HDD upgrade option kit contains the following components:
v One 2.5-inch hard disk drive backplane
v Four M3.5 screws
v One blank EMC filler
v Four drive bay filler panels
v Two backplane brackets
v One ServeRaid controller
v One SAS signal cable
v One internal power cable
v One backplane bracket
Chapter 2. Installing optional devices61
To install a 4-disk-drive optional hard disk drive backplane in a 8-drive-capable
server model, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and disconnect all power cords and external cables (see
“Turning off the server” on page 22).
3. Remove the server cover (see “Removing the cover” on page 44).
4. Remove the three 4-drive filler panels that are to the right of drive bay 4,
beneath the IDs4-15onthefront bezel.
5. To obtain more working room, remove fans 2 and 3 (see “Removing a
hot-swap fan” on page 115).
6. Pull the hard disk drives or fillers out of the server slightly to disengage them
from the backplanes. For more information, see“Removing a hard disk drive”
on page 59.
7. Disconnect the SAS signal cable from the SAS controller, which is connected
to the SAS riser-card. Leave the other end of the SAS signal cable connected
to the hard disk drive backplane.
8. Remove the SAS controller assembly from the server; then, remove the SAS
controller from the SAS riser-card. See “Removing a ServeRAID SAS
controller from the SAS riser-card” on page 121 for instructions.
62System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
9. Remove the SAS controller front retention bracket from the server.
10. Connect one end of the internal power cable that comes with the 4 Pac HDD
upgrade option kit into the hot-swap SAS/SATA power connector on the system
board.
11. Remove hard disk drive backplane from the server.
Chapter 2. Installing optional devices63
a. From backplane, disconnect the following cables in the order listed:
v Power cable 1
v SAS signal cable 2
v Configuration cable 3
b. Lift the backplane out of the server by pulling it toward the rear of the
server and then lifting it up.
12. Install the new backplane:
a. Move the SAS signal cable from the old hard disk drive backplane to the
new backplane 1. The new backplane comes with the option kit.
64System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
b. Connect the new power cable that comes with the option kit to the new
hard disk drive backplane 2.
c. Connect the configuration cable to the new backplane 3.
d. Angle the new backplane and place the bottom edge into the slots for it on
the chassis.
e. Rotate the backplane upright so that the bracket goes underneath the latch
and tabs on the chassis and is engaged into the slots on the backplane
bracket.
13. Make sure that the configuration cable is connected to the backplane.
14. Remove the rear controller retention bracket located in the battery bay above
the power supplies by pulling up the release tab 1 and sliding the bracket
outward 2.
Chapter 2. Installing optional devices65
15. Install the SAS controller front retention bracket that you got from step 14:
a. Align the retention bracket controller slot so that it faces the rear of the
server.
b. Place the bracket tabs in the holes on the chassis and slide the bracket to
left until it clicks into place.
16. Remove the fillers (if they are installed) from the two connectors on the SAS
controller that comes with the option kit.
17. Install the SAS controller:
a. Insert the SAS controller into the connector on the SAS riser-card.
b. Insert the front of the SAS controller into the front retention bracket.
c. Install the SAS riser-card with the SAS controller into the connector on the
system board, making sure that the alignment post goes through the hole
in the controller. Press the riser card into place until the latch at the rear of
the card snaps closed.
18. Connect the SAS signal cables to the SAS controller:
a. Connect the SAS signal cable from the right side of the hard disk drive
backplane to the right front connector on the SAS controller (as facing the
front of the server).
66System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
b. Connect the SAS signal cable that comes with the 4 Pac HDD upgrade
option kit from the left side of the hard disk drive backplane to the left front
connector on the SAS controller (as facing the front of the server).
19. If you removed any fans, install them.
20. Insert the hard disk drives and the fillers the rest of the way into the bays.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Installing a SAS/SATA 8 Pac HDD option
If the server is a 16-drive-capable model with eight hard disk drive bays installed,
you can install an IBM System x3650 M3 Hot-swap SAS/SATA 8 Pac HDD option.
See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of
supported optional devices. To order a SAS/SATA 8 Pac HDD option, contact your
IBM marketing representative or authorized reseller.
The SAS/SATA 8 Pac HDD option kit contains the following components:
v One 2.5-inch hard disk drive backplane
v One SAS expander card
v Four M3 screws
v One remote battery cable
v Eight blank EMC fillers
v Four SAS signal cables (one cable has a right-angle connector)
v One internal power cable
v Two backplane brackets
To install a 8-disk-drive optional hard disk drive backplane in a 16-drive-capable
server model, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and disconnect all power cords and external cables (see
“Turning off the server” on page 22).
3. Remove the server cover (see “Removing the cover” on page 44).
Chapter 2. Installing optional devices67
4. Remove the two 4-drive filler panels that are to the right of drive bay 8,
beneath the IDs8-15onthefront bezel.
5. To obtain more working room, remove fans 2 and 3 (see “Removing a
hot-swap fan” on page 115).
6. Pull the hard disk drives or fillers out of the server slightly to disengage them
from the backplanes. For more information, see“Removing a hard disk drive”
on page 59.
7. Disconnect the SAS signal cables from the SAS controller, which is connected
to the SAS riser-card. Leave the other end of the SAS signal cables connected
to the hard disk drive backplanes.
8. Remove the SAS controller assembly from the server; then, remove the SAS
controller from the SAS riser-card. See “Removing a ServeRAID SAS
controller from the SAS riser-card” on page 121 for instructions.
68System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
9. Remove the SAS controller front retention bracket from the server.
10. Connect one end of the internal power cable that comes with the 8 Pac HDD
option kit into the empty hot-swap SAS/SATA power connector on the system
board.
11. Remove hard disk drive backplane 1 from the server.
Chapter 2. Installing optional devices69
a. From backplane 1, disconnect the following cables in the order listed:
v Power cable 1
v SAS signal cable 2
v Configuration cable 3
b. Lift backplane 1 out of the server by pulling it toward the rear of the server
and then lifting it up.
12. Install the new backplane in slot 2:
a. Move the SAS signal cable from hard disk drive backplane 1 to new
backplane 2 1. The new backplane comes with the option kit.
70System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
b. Connect the new power cable that comes with the option kit to new hard
disk drive backplane 2 2.
c. Connect the configuration cable to backplane 2 3.
d. Angle the new backplane and place the bottom edge into the slots for
backplane 2 on the chassis next to the optical drive.
e. Rotate the backplane upright so that the bracket goes underneath the latch
13. Install hard disk drive backplane 1:
a. Connect the right-angle end of the longer SAS signal cable that comes with
and tabs on the chassis and is engaged into the slots on the backplane
bracket.
the option kit to hard disk drive backplane 1 1.
Chapter 2. Installing optional devices71
b. Reconnect the power cable 2 to backplane 1.
c. Reconnect the configuration cable 3 to backplane 1.
d. Angle the backplane and place the bottom edge into the slots for
backplane 1 on the chassis.
e. Rotate the backplane upright so that the bracket goes underneath the latch
and tabs on the chassis and is engaged into the slots on the backplane
bracket.
14. Make sure that the configuration cable is connected to all backplanes.
15. Remove the rear controller retention bracket located in the battery bay above
the power supplies by pulling up the release tab 1 and sliding the bracket
outward 2.
16. Install the SAS controller front retention bracket that you got from step 15:
72System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
a. Align the retention bracket controller slot so that it faces the rear of the
server.
b. Place the bracket tabs in the holes on the chassis and slide the bracket to
left until it clicks into place.
17. Remove the fillers (if they are installed) from the four connectors on the SAS
expander card that comes with the option kit.
18. Install the SAS expander card:
a. Insert the SAS expander card into the connector on the SAS riser-card.
b. Insert the front of the SAS expander card into the front retention bracket.
c. Install the SAS riser-card with the SAS expander card into the connector
on the system board, making sure that the alignment post goes through the
hole in the expander card. Press the riser card into place until the latch at
the rear of the card snaps closed.
Chapter 2. Installing optional devices73
19. If a battery and battery carrier are attached to the SAS controller that you
removed in step 8, disconnect the battery carrier cable from the battery and
remove the three screws that secure the battery carrier to the SAS controller.
Set the battery and battery carrier aside.
Note: The illustrations in this document might differ slightly from your
hardware.
20. Install the interposer card that comes with the option kit on the interposer card
connector on the SAS controller:
a. Remove the interposer card and the loose screw from the bag.
b. Rotate the standoff so that it aligns with the hole in the ServeRAID
controller, and position the interposer card connector over the SAS
controller connector.
c. Press the interposer card down onto the interposer card connector so that
the interposer card is secured.
74System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
d. From the other side of the SAS controller, insert and tighten the screw to
secure the interposer card to the SAS controller.
21. Remove the expansion-slot bracket that is screwed to the vertical wall above
the power supply and install the expansion-slot bracket on the SAS controller:
a. Orient the SAS controller as shown in the illustration.
b. Align the metal bracket so that the tabs are on the back side of the SAS
controller and the holes on the tabs align with the holes on the SAS
controller.
Chapter 2. Installing optional devices75
c. From the front side of the SAS controller, install the two screws that hold
the metal bracket onto the SAS controller.
22. If required, connect one end of the remote battery cable to the interposer card.
Attention:To avoid damage to the hardware, make sure that you align the
black dot on the cable connector with the black dot on the connector on the
interposer card. Do not force the remote battery cable into the connector.
23. Connect the SAS signal cables to the connectors on the SAS controller:
a. Connect the shorter SAS signal cable that comes with the option kit to the
SAS controller connector that is labeled “Ports 7-4”. If you are connecting
cables to a ServeRAID-MR10i SAS/SATA Controller, this connector is
closest to the edge of the controller and has two straight connectors.
Note: If you are connecting the shorter SAS signal cable to a
ServeRAID-BR10i v2 SAS/SATA Controller, the connectors are reversed.
You must connect the shorter SAS signal cable to the connector that is
labeled “Port 4–7”, which is the connector that is not the closest to the
edge of the controller.
76System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
b. Connect the straight connector end of the longer SAS signal cable to the
other SAS connector that is labeled “Ports 3-0” on a ServeRAID-MR10i
SAS/SAS Controller. This cable has a right-angle connector and a straight
connector.
Note: If you are connecting the longer SAS signal cable to a
ServeRAID-BR10i v2 SAS/SATA Controller, the connectors are reversed.
You must connect the straight connector end of the longer SAS signal
cable to the connector that is labeled “Port 0–3”.
24. Remove the PCI riser-card assembly (see “Removing a PCI riser-card
assembly” on page 45).
25. Orient the SAS controller so that the connectors are on the underside of the
controller. Install the SAS controller in the connector on the PCI riser card.
(See the previous illustration and see “Installing a PCI adapter” on page 52.)
26. Install the PCI riser-card assembly in the server (see “Installing a PCI
riser-card assembly” on page 46).
27. Connect the free end of the remote battery cable to the battery on the remote
battery tray. For more information, see “Installing a ServeRAID SAS controller
battery on the remote battery tray” on page 126.
28. Connect the SAS signal cables to the SAS expander card:
a. Connect the SAS signal cables from hard disk drive backplane 2 to the
right front connectors on the SAS expander card (as facing the front of the
server).
Chapter 2. Installing optional devices77
b. Connect the SAS signal cables from hard disk drive backplane 1 to the left
front connectors on the SAS expander card (as facing the front of the
server).
78System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
29. Connect the loose end of the SAS signal cables (the cables have straight
connectors and are already connected to the ServRAID controllers) to the rear
connectors on the SAS expander card. Route the cable underneath the cable
retention features on the baffle. See the illustration.
Note: The cables that connect to a ServeRAID-BR10i v2 SAS/SATA Controller
are reversed.
30. If you removed any fans, install them.
31. Insert the hard disk drives and the fillers the rest of the way into the bays.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 139.
Installing a SAS/SATA 8 Pac HDD for 2 RAID kit with 2 M5015 adapters
option
If the server is a 16-drive-capable model with eight hard disk drive bays installed,
you can install an IBM System x3650 M3 Hot-swap SAS/SATA 8 Pac HDD option.
See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of
supported optional devices. To order a SAS/SATA 8 Pac HDD for 2 RAID kit with 2
M5015 adapters option, contact your IBM marketing representative or authorized
reseller.
The SAS/SATA 8 Pac HDD for 2 RAID kit with 2 M5015 adapters option contains
the following components:
v One 2.5-inch hard disk drive backplane
Chapter 2. Installing optional devices79
v Two M5015 adapters
v Four M3 screws
v Eight blank EMC fillers
v Two SAS signal cables
v One remote battery cable
v One internal power cable
v Two backplane brackets
To install a SAS/SATA 8 Pac HDD for 2 RAID kit with 2 M5015 adapters in a
16-drive-capable server model, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Turn off the server and disconnect all power cords and external cables (see
“Turning off the server” on page 22).
3. Remove the server cover (see “Removing the cover” on page 44).
4. Remove the two 4-drive filler panels that are to the right of drive bay 8,
beneath the IDs8-15onthefront bezel.
5. To obtain more working room, remove fans 2 and 3 (see “Removing a
hot-swap fan” on page 115).
6. Pull the hard disk drives or fillers out of the server slightly to disengage them
from the backplanes. For more information, see“Removing a hard disk drive”
on page 59.
7. Disconnect the SAS signal cables from the SAS controller, which is connected
to the SAS riser-card. Leave the other end of the SAS signal cables connected
to the hard disk drive backplanes.
80System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
8. Remove the SAS controller assembly from the server; then, remove the SAS
controller from the SAS riser-card. See “Removing a ServeRAID SAS
controller from the SAS riser-card” on page 121 for instructions.
9. Remove the SAS controller front retention bracket from the server.
Chapter 2. Installing optional devices81
10. Connect one end of the internal power cable that comes with the 8 Pac HDD
option kit into the empty hot-swap SAS/SATA power connector on the system
board.
11. Remove hard disk drive backplane 1 from the server.
a. From backplane 1, disconnect the following cables in the order listed:
v Power cable 1
v SAS signal cable 2
v Configuration cable 3
82System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide
b. Lift backplane 1 out of the server by pulling it toward the rear of the server
and then lifting it up.
12. Install the new backplane in slot 2:
a. Move the SAS signal cable from hard disk drive backplane 1 to new
backplane 2 1. The new backplane comes with the option kit.
b. Connect the new power cable that comes with the option kit to new hard
disk drive backplane 2 2.
c. Connect the configuration cable to backplane 2 3.
d. Angle the new backplane and place the bottom edge into the slots for
backplane 2 on the chassis next to the optical drive.
Chapter 2. Installing optional devices83
e. Rotate the backplane upright so that the bracket goes underneath the latch
and tabs on the chassis and is engaged into the slots on the backplane
bracket.
13. Install hard disk drive backplane 1:
a. Connect the right-angle end of the longer SAS signal cable that comes with
the option kit to hard disk drive backplane 1 1.
b. Reconnect the power cable 2 to backplane 1.
c. Reconnect the configuration cable 3 to backplane 1.
d. Angle the backplane and place the bottom edge into the slots for
backplane 1 on the chassis.
e. Rotate the backplane upright so that the bracket goes underneath the latch
and tabs on the chassis and is engaged into the slots on the backplane
bracket.
14. Make sure that the configuration cable is connected to all backplanes.
15. Remove the rear controller retention bracket located in the battery bay above
the power supplies by pulling up the release tab 1 and sliding the bracket
outward 2.
84System x3650 M3 Types 4255, 7945, and 7949: Installation and User’s Guide