The steps you perform in the remainder of this document will provide you with remote network access
to the appliance so that you can perform more advanced configuration tasks.
You can find more advanced configuration information in the "Configuring" section of the SiteProtector
online Help.
Gather materials
You must prepare some information and gather your equipment before you can install your SiteProtector
System appliance.
UMaterials
hIBM Security SiteProtector System SP3001 appliance
hEthernet cable (included with appliance)
h2 power cords (included with appliance)
Gather network information
Use this table to record important network information you need to configure the appliance:
SettingsYour Settings
IP Address (required)__________ . __________ . __________ . __________
Use this space to record the appliance's SQL Server license Product Key and Tracking IDs.
The Product Key and Tracking IDs can be found on the Certificate of Authenticity that is affixed to the
appliance or in the accessory box. You will need them in the event of an RMA return.
Important: Save all the Product Key and Tracking ID information in a safe place.
SQL Server Product Key _______________________________
Tracking ID _________________________________________
Tracking ID _________________________________________
2SiteProtector SP3001: Getting Started Guide
Page 3
Connect the appliance
Follow this procedure to connect and power up the SiteProtector System appliance.
Procedure
1. Connect both power cords to the appliance to prevent warning signals from sounding.
2. Connect the network to the management interface port 0 using the supplied Ethernet cable. Note that
management port 1 should remain unused
3. Turn on the appliance. The power button is located on the front of the appliance.
4. When the LCD display reads "IBM Security SiteProtector SP3001," proceed to Initial Configuration.
Initial configuration
Enter the network information you gathered earlier.
Procedure
1. Press Enteron the LCD panel. "Appliance PIN" appears in the LCD menu.
2. If you want to specify a personal identification number that users must enter to configure the
appliance, press Enter
again.
Note: Use the Up
buttons to navigate between the fields.
3. To configure the appliance to communicate with other devices, navigate to the Configuration menu
(using the Up
configuration. Enter the information the same way you entered information in Step 2.
v IP Address (required)
v Subnet Mask
v Default Gateway
v DNS Server
v Host Name
Note: Certain characters cannot be used in the Host Name. See the Microsoft article at
http://support.microsoft.com/kb/909264 for details on naming conventions.
Note: A reboot occurs after you complete your network configuration.
, specify a 4-digit number in the field provided, and then press Enter
and Downbuttons to specify digits and the Rightand Left
and Downbuttons), then press the Enterbutton to begin the network
Next steps
Install a Console
Select a local computer on which to install a SiteProtector Console.
IBM Security SiteProtector System SP3001 Getting Started Guide3
Page 4
Procedure
1. Access the IBM Security Download Center at https://ibmss.flexnetoperations.com.
2. Login to the IBM Security Download Center and click Download under the My software heading.
3. Under My Products, click IBM Security SiteProtector System.
4. Under Product Lines, click SiteProtector 3.1.
5. Click the Installation Packages link.
6. Download the Console-Setup.exe package to a known location.
7. Run Console-Setup.exe.
8. Read and accept the End User License Agreement.
9. Follow the installation prompts and enter any required information. The Console and Event Viewer
are installed on the computer.
Launch Console and log in
Follow these instructions to access the SiteProtector Console and log into it.
Procedure
1. Launch the SiteProtector Console.
2. Right-click the My Sites node in the navigation pane.
3. Select New > Site.
4. Enter the following information:
OptionDescription
ServerThe IP address configured during initial configuration.
UserAdministrator
PasswordISSADMIN
Configure advanced settings
See the "Configuring" section of the SiteProtector System online Help for detailed information.
Procedure
1. Change the Administrative Password.
2. Change the Database (SA) Password.
Configure your Site
The "Configuring" section of the SiteProtector System online Help walks you through other important
tasks such as configuring your security policy, creating firewall rules to protect your network, tracking
alerts, and monitoring important system information.