Note: Before using this information and the product it supports, read the Warranty Information document, the general information in
Appendix B, “Notices,” on page 67, and the Important Notices document that comes with the product. Read the IBM Safety Notices
and the License Agreement for Machine Code (LAMC) document on the IBM Documentation CD. Read the Environmental Noticesand User Guide on the IBM Environmental Notices CD.
Läs säkerhetsinformationen innan du installerar den här produkten.
Bu ürünü kurmadan önce güvenlik bilgilerini okuyun.
Important:
Each caution and danger statement in this document is labeled with a
number. This number is used to cross reference an English-language
caution or danger statement with translated versions of the caution or
danger statement in the Safety Information document.
For example, if a caution statement is labeled “D005,” translations for
that caution statement are in the Safety Information document under
“D005.”
Be sure to read all caution and danger statements in this document
before you perform the procedures. Read any additional safety
information that comes with the switch or optional device before you
install the device.
DANGER
Hazardous voltage, current, or energy levels are present inside any
component that has this label attached. Do not open any cover or barrier
that contains this label.
(L001)
DANGER
Rack-mounted devices are not to be used as shelves or work spaces.
(L002)
ivIBM System Networking RackSwitch G8264CS: Installation Guide
Page 7
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
or
1
2
!
1
2
Safetyv
Page 8
DANGER
An electrical outlet that is not correctly wired could place hazardous
voltage on the metal parts of the system or the devices that attach to the
system. It is the responsibility of the customer to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock. (D004)
viIBM System Networking RackSwitch G8264CS: Installation Guide
Page 9
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication
cables are hazardous. To avoid a shock hazard:
v Connect power to this unit only with the IBM provided power cord. Do
not use the IBM provided power cord for any other product.
v Do not open or service any power supply assembly.
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
v The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
v Connect all power cords to a properly wired and grounded electrical
outlet. Ensure that the outlet supplies proper voltage and phase rotation
according to the system rating plate.
v Connect any equipment that will be attached to this product to properly
wired outlets.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3. Remove the signal cables from the connectors.
4. Remove all cables from the devices.
To connect:
1. Turn off everything (unless instructed otherwise).
2. Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
v Sharp edges, corners and joints may be present in and around the
system. Use care when handling equipment to avoid cuts, scrapes and
pinching.
(D005)
Safetyvii
Page 10
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of a fiber optical cable or open
receptacle. (C027)
CAUTION:
This product contains a Class 1M laser. Do not view directly with optical
instruments. (C028)
viiiIBM System Networking RackSwitch G8264CS: Installation Guide
Page 11
DANGER
Observe the following precautions when working on or around your IT rack
system:
v Heavy equipment—personal injury or equipment damage might result if
mishandled.
v Always lower the leveling pads on the rack cabinet.
v Always install stabilizer brackets on the rack cabinet.
v To avoid hazardous conditions due to uneven mechanical loading,
always install the heaviest devices in the bottom of the rack cabinet.
Always install servers and optional devices starting from the bottom of
the rack cabinet.
v Rack-mounted devices are not to be used as shelves or work spaces. Do
not place objects on top of rack-mounted devices.
v Each rack cabinet might have more than one power cord. Be sure to
disconnect all power cords in the rack cabinet when directed to
disconnect power during servicing.
v Connect all devices installed in a rack cabinet to power devices installed
in the same rack cabinet. Do not plug a power cord from a device
installed in one rack cabinet into a power device installed in a different
rack cabinet.
v An electrical outlet that is not correctly wired could place hazardous
voltage on the metal parts of the system or the devices that attach to the
system. It is the responsibility of the customer to ensure that the outlet
is correctly wired and grounded to prevent an electrical shock.
(R001 part 1 of 2)
Safetyix
Page 12
CAUTION:
v Do not install a unit in a rack where the internal rack ambient temperatures
will exceed the manufacturer’s recommended ambient temperature for all
your rack-mounted devices.
v Do not install a unit in a rack where the air flow is compromised. Ensure
that air flow is not blocked or reduced on any side, front, or back of a unit
used for air flow through the unit.
v Consideration should be given to the connection of the equipment to the
supply circuit so that overloading of the circuits does not compromise the
supply wiring or overcurrent protection. To provide the correct power
connection to a rack, refer to the rating labels located on the equipment in
the rack to determine the total power requirement of the supply circuit.
v (For sliding drawers) Do not pull out or install any drawer or feature if the
rack stabilizer brackets are not attached to the rack. Do not pull out more
than one drawer at a time. The rack might become unstable if you pull out
more than one drawer at a time.
v (For fixed drawers) This drawer is a fixed drawer and must not be moved
for servicing unless specified by the manufacturer. Attempting to move the
drawer partially or completely out of the rack might cause the rack to
become unstable or cause the drawer to fall out of the rack.
(R001 part 2 of 2)
Important:
Important:
This product is also designed for IT power distribution systems with
phase-to-phase voltage of 230V.
Machinenlärminformations-Verordnung - 3. GPSGV, der höchste
Shalldruckpegel beträgt 70 dB (A) oder weniger.
xIBM System Networking RackSwitch G8264CS: Installation Guide
Page 13
Contents
Safety ............................iii
Chapter 1. Introduction ......................1
The IBM Documentation CD....................1
Hardware and software requirements .................2
Related documentation ......................2
Notices and statements in this document................2
Federal Communications Commission (FCC) statement .........70
Industry Canada Class A emission compliance statement ........71
Avis de conformité à la réglementation d'Industrie Canada ........71
Australia and New Zealand Class A statement ............71
European Union EMC Directive conformance statement.........71
Germany Class A statement ...................71
VCCI Class A statement....................72
Japan Electronics and Information Technology Industries Association (JEITA)
statement .........................72
Korea Communications Commission (KCC) statement .........73
Russia Electromagnetic Interference (EMI) Class A statement.......73
People's Republic of China Class A electronic emission statement .....73
Taiwan Class A compliance statement ...............73
Index ............................75
xiiIBM System Networking RackSwitch G8264CS: Installation Guide
Page 15
Chapter 1. Introduction
This Installation Guide provides information and instructions for installing, updating
the firmware, and solving problems for an IBM
G8264CS. For information about configuration and management of the converged
switch, see the Command Reference for the IBM System Networking RackSwitch
G8264CS and the product release notes.
The IBM System Networking RackSwitch G8264CS (converged switch) is a
rackable aggregation switch with unmatched line-rate Layer 2 and Layer 3
performance. The IBM System Networking RackSwitch G8264CS uses a
wire-speed, non-blocking switching fabric that provides simultaneous wire-speed
transport of Ethernet packets at low latency on all ports.
The IBM System Networking RackSwitch G8264CS contains thirty-six 10 GbE small
form-factor pluggable plus (SFP+) ports and four 40 GbE quad small form-factor
pluggable plus (QSFP+) ports, and twelve Omni Ports. Omni Port technology allows
the same port to be used as a 10 Gb Ethernet port (SFP+) or as a 4 Gbps or 8
Gbps Fibre Channel port. The SFP+ ports can be populated with optical or copper
transceivers, or Direct Attach Cables (DACs). The QSFP+ ports can be populated
with optical QSFP+ transceivers or DACs.
The IBM System Networking RackSwitch G8264CS provides support for Layer 2
and Layer 3 switching and routing, including Converged Enhanced Ethernet (CEE),
10 Gb Ethernet switching, Fibre Channel over Ethernet (FCoE) and FC/FCoE
capabilities NPV (N_Port Virtualization) Gateway, and Full Fabric FC/FCoE switch.
®
System Networking RackSwitch
™
You can manage the switch through the console port, or through a network
connection using Telnet, a web browser-based interface, or SNMP-based network
management software. For more information, see Chapter 4, “Initializing the
RackSwitch,” on page 49.
If documentation updates are available, you can download them from
http://www.ibm.com/supportportal/. The switch might have features that are not
described in the documentation that comes with the switch, and the documentation
might be updated occasionally to include information about those features, or
technical updates might be available to provide additional information that is not
included in the switch documentation.
To check for documentation updates,
1. Go to http://www.ibm.com/supportportal/ and click Documentation.
2. In the Quick find field enter the name of your product and press Enter.
Note: Changes are made periodically to the IBM website. Procedures for locating
firmware and documentation might vary slightly from what is described in this
document.
The IBM Documentation CD
The IBM Documentation CD contains documentation for your switch in Portable
Document Format (PDF).
The Documentation CD includes the product installation guide, safety document and
the License Agreement for Machine Code (LAMC) document. The EnvironmentalNotices CD includes the Environmental Notices for the product. To access these
documents:
v If you are using a Windows operating system, insert the CD into the CD or DVD
drive and from My Computer, double click the CD or DVD drive and select the
installation guide that supports your product.
v If you are using a Linux operating system, insert the CD into the CD or DVD
drive and run the following command from the mnt/cd directory, sh.linux.sh.
Select the installation guide that supports your product.
Double click on the Installation Guides directory and select the installation guide
that supports your product.
Hardware and software requirements
The IBM Documentation CD requires the following minimum hardware and
software:
v Microsoft Windows NT 4.0 (with Service Pack 3 or later), Windows 2000, or Red
Hat Linux.
v 100 MHz microprocessor.
v 32 MB of RAM.
v Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
systems.
Related documentation
The following related documentation is available at http://www.ibm.com/systems/
support/:
v IBM System Networking RackSwitch G8264CS Application Guide
v IBM System Networking RackSwitch G8264CS Menu-based Command
Reference
v IBM System Networking RackSwitch G8264CS ISCLI–Industry Standard CLI
Command Reference
v IBM System Networking RackSwitch G8264CS BBI Quick Guide
Notices and statements in this document
The caution and danger statements in this document are also in the multilingual
Safety Information document, which is on the IBM Documentation CD. Each
statement is numbered for reference to the corresponding statement in the SafetyInformation document.
The following notices and statements are used in this document:
v Note: These notices provide important tips, guidance, or advice.
v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
2IBM System Networking RackSwitch G8264CS: Installation Guide
Page 17
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
RackSwitch G8264CS features
This section provides an overview of IBM System Networking RackSwitch G8264CS
features.
Performance
v 1.2 Tbps Ethernet throughput (full duplex), non-blocking switching architecture
v 100% Ethernet line rate
Management Features
v Clients
– Industry standard command-line interface (ISCLI)
– Browser-based Interface (BBI)
–System Networking Switch Center
v Protocols
– SNMP v1, v2, v3
– Remote Monitoring (RMON)
– Network Time Protocol (NTP) support
– DHCP
v Software upgrades
– Dual software images
– Upgrade via serial, browser, or TFTP
Software Features
v Security
– Secure interface login and password
– RADIUS and TACACS+
– SSH v2
– HTTPS Secure Browser-based interface
– Wire-speed filtering with Access Control Lists (ACLs)
v Layer 2
– 1024 VLANs (802.1Q), including Private VLANs
– Multi-link trunking, compatible with Cisco EtherChannel
– LACP (IEEE 802.3ad)
– Per VLAN Rapid Spanning Tree -- PVRST+
– Spanning Tree (802.1s), Multiple Spanning Tree (802.1s), Rapid Spanning
Tree (802.1w), with Fast Uplink Convergence
– 128 K forwarding database entries
v Layer 3
– Dynamic routing
- RIP v1, v2
- OSPF
- BGP
Chapter 1. Introduction3
Page 18
– 128 configurable interfaces (static or DHCP)
– DHCP Relay
– IP forwarding
– IGMP Snooping v1, v2, v3
– 8 K ARP entries
– IPv6 host management
v Quality of service
– 802.1p priority queues
– Differentiated Services Code Point (DSCP) support
v Convergence
– Support for IBM vNIC (virtual Network Interface Card) Virtual Fabric Adapter
– Support for Converged Enhanced Ethernet (CEE) (PFC, ETS, DCBX)
v Availability
– Layer 2 failover
– Hot links
– VRRP
Major components
This section describes the IBM System Networking RackSwitch G8264CS hardware
components.
Hardware options
The following list provides an overview of G8264CS hardware:
v Switch unit
v Mounting hardware
v Hot-swap power supply (2)
v Hot-swap fans (4)
Switch unit
The switch unit is a 1U rack-mountable scalable switch. You can mount it in either
the horizontal or vertical direction.
The switch allows for flexible mounting, as follows:
v IBM System Networking RackSwitch G8264CS (front-to-rear) provides
vIBM System Networking RackSwitch G8264CS (rear-to-front) provides
Ports
The switch unit contains the following ports:
v Thirty-six 10 GbE SFP+ ports and twelve Omni Ports (which can be used as
v Four QSFP+ ports
– Standard 2-post rack mounting brackets and screws
®
– IBM iDataPlex
– IBM System-x 4-post rack mounting brackets and screws (purchased
separately)
front-to-rear airflow.
rear-to-front airflow.
SFP+ or FC ports)
rack mounting brackets and screws (purchased separately)
4IBM System Networking RackSwitch G8264CS: Installation Guide
Page 19
v RJ-45 port management port
v USB port for mass storage
v RS-232 (mini USB) serial console port
The following illustrations show the ports and controls on the front and rear of the
switch.
Figure 1. IBM System Networking RackSwitch G8264CS front panel
Figure 2. IBM System Networking RackSwitch G8264CS front panel detail
Figure 3. IBM System Networking RackSwitch G80264CS rear panel
Reset button
The Reset button is recessed within a hole on the front panel. Use a straightened
paper clip or similar object to press the Reset button. The Reset button enables you
to reset the switch, as follows:
v Press Reset: The switch resets and reloads the configuration files.
v Press and hold Reset for five seconds: The switch resets and configures all
settings to the factory defaults.
Fans
Four hot-swap internal fans cool the switch unit and are required for normal
operation. If an individual fan fails, the other fans continue to run, and the switch
unit continues to operate normally. You can replace a hot-swap fan module while
the switch is operating.
Chapter 1. Introduction5
Page 20
Fan operation and internal temperatures are monitored. If the air temperature
exceeds a threshold, the environmental monitor displays warning messages.
Note: If a fan module fails, the maximum operating temperature drops from 40°C to
35°C (104°F to 95°F).
The Service(!)LEDislitifthere is a failure of one or more fan modules. The
failed fan module LED (rear panel) flashes to indicate a failure.
AC power supply
The switch has two hot-swap AC power supplies, 550 W for front-to-rear or 750 W
for rear-to-front. Each internal power supply has an individual IEC 320 power
connector on the rear panel. The power cord attaches to a universal grounded AC
power source. You can replace a hot-swap power supply module without powering
off the switch or disrupting switch functions.
DANGER
Multiple power cords. This product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
or
1
2
!
1
2
6IBM System Networking RackSwitch G8264CS: Installation Guide
Page 21
Switch ports
DANGER
An electrical outlet that is not correctly wired could place hazardous
voltage on the metal parts of the system or the devices that attach to the
system. It is the responsibility of the customer to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock. (D004)
Each power supply can be connected to a separate AC circuit to mitigate the risk of
down time during a power failure. When used in a redundant configuration, the dual
power supplies have a load-sharing capability that enables each power supply to
operate at approximately 50 percent of full load. Using redundant power can
minimize the power disruption during a power supply failure and extend the
expected lifetime of each power supply by operating normally in a conservative
power mode.
There is no power switch on the IBM System Networking RackSwitch G8264CS;
the switch unit powers up when power is supplied through the power cords.
The Power Supply LED indicates the status of the power supplies. The LED flashes
when only one power cord is connected, and is steady when both power cords are
connected.
The switch ports and port options are described in the following sections.
v “SFP+ ports”
v “QSFP+ ports” on page 8
v “Fibre Channel/Ethernet Omni Ports” on page 9
v “Console port” on page 9
v “USB port” on page 10
SFP+ ports
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
Chapter 1. Introduction7
Page 22
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of an optical fiber cable or open
receptacle. (C027)
Forty-eight 10 GbE SFP+ ports (twelve ports can be used as SPF+ Omni Ports) are
located on the front panel. These ports accept approved optical or copper SFP and
SFP+ transceivers and SFP+ active and passive DAC cables. Transceivers must be
purchased separately.
For the available transceivers for the switch, see https://www-01.ibm.com/products/
hardware/configurator/americas/bhui/launchNI.wss.
QSFP+ ports
Four 40 GbE QSFP+ ports are located on the front panel. These ports accept
supported optical QSFP+ transceivers or DACs. The supported transceivers
interoperate with any 40 GBASE-SR4 compliant device, and support distances up
to 100 meters on OM3 fiber. Transceivers must be purchased separately.
QSFP+ ports allow you to make one 40 GbE connection, or four 10 GbE
connections, using a breakout cable, as follows:
v QSFP+ optical transceiver with MTP-to-4 LC (SFP+) fiber breakout cable. This
option supports only IBM 10 GBASE-SR SFP+ transceivers. The 40 GBASE-SR4
specification (802.3ba-2010) indicates a higher optical power level than standard
10 GBASE-SR. IBM SFP+ SR transceivers can handle the higher optical power
levels. This cable must be purchased separately from your fiber cable supplier.
v QSFP+ to four 10 GbE SFP+ breakout DAC. The SFP+ connectors on supported
breakout DACs are labelled A, B, C, and D, which correspond to the first,
second, third, and fourth ports in the port range. This cable must be purchased
separately from your fiber cable supplier.
For the available QSFP+ transceivers and DACs for the switch, see
https://www-01.ibm.com/products/hardware/configurator/americas/bhui/launchNI.wss.
8IBM System Networking RackSwitch G8264CS: Installation Guide
Page 23
Fibre Channel/Ethernet Omni Ports
Features of Fibre Channel/Ethernet Omni Ports include:
v Each Omni Port is capable of running in 10 Gb Ethernet mode or four to eight
Gb Fibre Channel (FC) mode with auto-negotiation capability.
v Support for NPV (N_Port Virtualization) Gateway provides connectivity to the
Fibre Channel SAN.
v Support for FC-BB-5 Compliant Full Fabric FC/FCoE switch. Fabric Services are
Name Server, Registered State Change Notification (RSCN), Login Services and
Zoning (WWN, FCID or Alias-based Zoning).
Console port
The RS-232 (mini-USB) serial console port is located on the front panel, see
Figure 1 on page 5. The following table describes the pinouts for the mini-USB port.
The RJ-45 (copper) external management port is located on the front panel, see
Figure 1 on page 5. A retention clip is available to secure the console connection.
The following table describes the pin assignments for the RJ-45 connector on the
console cable.
Table 2. RJ-45 connector pin assignments
Pin numberFunction
1RTS (Request To Send)
2DTR (Data Terminal Ready)
3TxD (Transmit Data)
4GND (Ground)
5GND (Ground)
6RxD (Receive Data)
7DSR (Data Set Ready)
8CTS (Clear To Send)
The following items are also included with the console cable.
v Category 5 patch cable
v RJ-45 to female DB9 adapter
To connect a computer or terminal to the switch, first connect the console cable to
the mini-USB port on the front panel. Connect one end of the patch cable to the
RJ-45 port on the console cable, and the other end of the patch cable to the
RJ-45-to-DB9 adapter (see the following illustration).
Chapter 1. Introduction9
Page 24
Switch LEDs
To
Switch
Switch
Console Cable
Figure 4. Console cable connections
Category 5
Patch Cable
RJ-45 Adapter
To P C
Terminal
USB port
The USB port is located on the front panel, see Figure 1 on page 5. It allows you to
connect a USB drive to the switch. You can copy files from the switch to the USB
drive, or from the USB drive to the switch. You can also start the switch using files
on the USB drive.
For more information about using the USB drive, see the IBM System NetworkingRackSwitch G8264CS Release Notes.
The following illustration shows the switch LEDs.
Figure 5. Switch status LEDs
The switch and port link status LEDs are described in the following table.
Table 3. Switch LEDs
SymbolDescription
!Service LED
Power supplies and power input status
Fan status
SStacking indicator
10IBM System Networking RackSwitch G8264CS: Installation Guide
Page 25
The switch LEDs are located on the front panel and are described in the following
table.
Table 4. Switch LED descriptions
FunctionMasterMemberPower supplyService
Total Power FailureOffOffOffOff
Service RequiredFlashing blueSee belowSee belowSee below
Power Supplies OKOffSolid greenNot applicableNot applicable
Power Supply Failure Flashing blueFlashing greenNot applicableNot applicable
Fans OKOffNot applicableNot applicableNot applicable
Fan FailureFlashing blueNot applicableFlashing greenNot applicable
RJ-45 LEDs
The RJ-45 LEDs are shown in the following illustration.
RJ-45 port LEDs
Link LED
Status LEDs for the RJ-45 ports are located on the front panel and are described in
the following table.
Activity LED
Table 5. RJ-45 LEDs status
LEDSteady greenFlashing AmberOff
LinkLink upNot applicableNo link
ActivityNot applicableActivityNo activity
SFP+ LEDs
Status LEDs for the SFP+ ports are located on the front panel and are described in
the following table.
Table 6. SFP+ LEDs status
Steady greenFlash greenOff
Link upActivityNo Link
QSPF+ LEDs
The QSFP+ LEDs are shown in the following illustration.
QSFP+
LEDs
Figure 6. QSFP+ LEDs
Chapter 1. Introduction11
Page 26
Status LEDs for the QSFP+ ports are described in the following table. When the
port is 40 GbE mode, only the first LED applies. When the port is in four 10 GbE
mode, each LED provides status for its corresponding 10 GbE port, as noted in the
following table.
Table 7. QSFP+ LEDs status
Steady
LED
QSFP+ linkValid linkActivityNot
QSFP+
speed
green
10 Gb SFP+Not
Flashing
green
applicable
Solid
Amber
applicable
Not
applicable
Flashing
AmberOff
Not applicable No link
Not applicable 1 Gb SFP
Omni Port LEDs
Status LEDs for the Omni Ports are located on the front panel and are described in
the following table.
Table 8. Omni Port LEDs status
Steady
LED
LinkValid linkActivityNot
Speed10G 4/8 GbNot
ModeThe port pair
green
is configured
for FC mode.
Flashing
greenSolid Amber
applicable
Not
applicable
One or both
of the
installed
devices is not
compatible
with the
mode
configured
(Ethernet/FC)
for the port
pair.
applicable
Not
applicable
Flashing
AmberOff
Not applicable No link
Not applicable Not
applicable
Not applicable The port pair
is configured
for Ethernet
mode.
Technical specifications
The IBM System Networking RackSwitch G8624CS technical specifications are
described in the following sections.
Physical characteristics
The physical characteristics of the System Networking RackSwitch G8264CS are
listed in the following table.
Table 9. Physical characteristics
SpecificationPhysical characteristics
Dimensions (HxWxD)4.45 x 43.9 x 48.26 cm.
Weight10.35 kg. (22.1 lb) (maximum)
AirflowFront-to-rear, rear-to-front
12IBM System Networking RackSwitch G8264CS: Installation Guide
(1.75 x 17.3 x 19 in.)
Page 27
Environmental specifications
The environmental specifications for the switch are listed in the following table.
Table 10. Environmental specifications
SpecificationMeasurement
Temperature, ambient operating0° C to +40° C (32° F to 104° F) with four
Temperature (fan failure), operating0° C to +35° C ( 32° F to 95° F) with four
Temperature, storage-40° C to +85° C (-40° F to 167° F)
Relative humidity (non-condensing),
operating
Relative humidity (non-condensing), storage10 to 90%
Altitude, operating1,800 m (6,000 ft)
Altitude, storage12,190 m (40,000 feet)
Acoustic noiseLess than 65 dB
Heat dissipation1127 BTU/hour (typical)
Power specifications
The power specifications for the switch are listed in the following table.
fans
fans
10 to 90%
1280 BTU/hour (maximum)
Table 11. AC power specifications
SpecificationMeasurement
Number of power supplies2 (1+1 load sharing/redundant)
AC-input frequency (universal)50/60 Hz
AC-input voltage (universal)100 - 127 VAC
200 - 240 VAC
AC inrush current15 A
AC-input current (typical)2.09 A (RMS) @ 120 V
1.10 A (RMS) @ 230 V
AC-input current (maximum)2.28 A (RMS) @ 120 V 1.30 A (RMS) @ 230
V
Power supply rated output power550 W
750 W
System power dissipation (typical)253 W
System power dissipation (maximum)276 W
DC-output current20.6 A (typical)
Chapter 1. Introduction13
Page 28
14IBM System Networking RackSwitch G8264CS: Installation Guide
Page 29
Chapter 2. Installing the RackSwitch and options
This chapter describes the how to install the RackSwitch chassis and the
associated RackSwitch components
v “Installing the RackSwitch in a standard equipment rack” on page 19
v “Installing the RackSwitch in an IBM iDataPlex rack” on page 22
v “Installing the RackSwitch in an IBM System x or Power rack” on page 25
v “Installing the 1U air duct option” on page 28
v “Installing an SFP, SFP+, QSFP+, and Omni Port transceiver” on page 32
Note: When replacing a RackSwitch chassis, all internal components must also be
removed from the chassis and replaced in the new chassis. For more
information on removing and replacing the RackSwitch and components, see
Chapter 3, “Removing and replacing the RackSwitch and components,” on
page 37.
Before installing the RackSwitch
Locate and record the important product information about the switch in the
following table. The identification labels contain the machine-type model (MTM)
number, serial number and part number (front, rear panel and/or bottom of the unit),
and the media access control (MAC) address (rear of unit) for the switch. The MAC
address is not required for opening a service call.
You can also review and record your product serial number and other required
information through the software interface by issuing the show sys-info command
using the ISCLI interface or the /info/sys/general command using the MenuCLI
interface. For more information about these commands, see “Configuring Vital
Product Data after a switch replacement” on page 46.
After the switch is installed most of the identification labels are hidden from view
and require removing the switch in order to relocate them.
Attention:This product information is required to register your product, to update
your firmware, place a service call, and replace the RackSwitch.
Note: The following sample RackSwitch identification (ID) labels may have different
Record this information below and print this page and keep it in a safe place for
future reference. You will need this information when you register the switch or open
a service call with IBM. You can register the switch at http://www.ibm.com/support/
mysupport/.
Product nameIBM System Networking RackSwitch G8264CS
Model number_____________________________________________
Serial number_____________________________________________
Part number_____________________________________________
Media access control
(MAC) address for switch
MAC addresses for other
components
_____________________________________________
_____________________________________________
_____________________________________________
_____________________________________________
You need the following tools or equipment to install the IBM System Networking
RackSwitch G8264CS:
v Standard flat-blade screwdriver
v #2 Phillips screwdriver
v Electrostatic discharge wrist strap
Package contents
The basic package contains the following items:
v Switch unit (one of the following)
– IBM System Networking RackSwitch G8264CS (front-to-rear) front-to-rear
airflow
16IBM System Networking RackSwitch G8264CS: Installation Guide
Page 31
– IBM System Networking RackSwitch G8264CS (rear-to-front) rear-to-front
airflow
v One Standard rack-mount kit that includes:
– Two brackets
– Screws to attach brackets to the switch unit
– Screws to attach the switch unit to the equipment rack
v Mini-USB to RJ-45 serial cable, category 5 patch cable, RJ-45 to DB9 adapter
v One AC power cords
v One IBM Documentation CD which includes the Installation Guide (this
document) and the IBM Systems Safety Notices document.
v One Environmental Notices CD
v One Warranty Information document
v One Important Notices document
Environmental requirements
This section describes the basic environmental requirements for the RackSwitch.
Make sure the location where you install the switch meets the following
requirements:
v Install the switch unit in a dry, clean, well-ventilated area.
v Provide adequate space in the front and back of the switch unit, to ensure proper
air flow.
v Make sure that an adequate grounded power supply is within reach of the switch
unit.
v Make sure that twisted-pair cable is routed away from power lines, fluorescent
lighting fixtures and other sources of electrical interference.
Preventing electric shock
This product does not contain any user-serviceable parts. Do not remove the cover
of this device.
The RackSwitch AC power model is designed to work with single-phase power
systems that have a grounded neutral conductor. To reduce the risk of electric
shock, always plug the power cord into a grounded power outlet.
Chapter 2. Installing the RackSwitch and options17
Page 32
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication
cables are hazardous. To avoid a shock hazard:
v Connect power to this unit only with the provided power cord. Do not
use the provided power cord for any other product.
v Do not open or service any power supply assembly.
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
v The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
v Connect all power cords to a properly wired and grounded electrical
outlet. Ensure that the outlet supplies proper voltage and phase rotation
according to the system rating plate.
v Connect any equipment that will be attached to this product to properly
wired outlets.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3. Remove the signal cables from the connectors.
4. Remove all cables from the devices.
To connect:
1. Turn off everything (unless instructed otherwise).
2. Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
(D005)
18IBM System Networking RackSwitch G8264CS: Installation Guide
Page 33
Handling static-sensitive devices
Attention:Static electricity can damage the switch and other electronic devices.
To avoid damage, keep static-sensitive devices in their static-protective packages
until you are ready to install them.
To reduce the possibility of electrostatic discharge, observe the following
precautions:
v Limit your movement. Movement can cause static electricity to build up around
you.
v The use of a grounding system is recommended. For example, wear an
electrostatic-discharge wrist strap, if one is available.
v Handle the device carefully, holding it by its edges or its frame.
v Do not touch solder joints, pins, or exposed printed circuitry.
v Do not leave the device where others can handle and damage it.
v While the device is still in its static-protective package, touch it to an unpainted
metal part of any unpainted metal surface on a grounded rack component in the
rack in which you are installing the device, for at least 2 seconds. This drains
static electricity from the package and from your body.
v Remove the device from its package and install it directly into the switch without
setting it down. If it is necessary to set down the device, put it back into its
static-protective package. Do not place the device on a switch cover or on a
metal surface.
v Take additional care when you handle devices during cold weather. Heating
reduces indoor humidity and increases static electricity.
Installing the RackSwitch in a standard equipment rack
This section describes how to install the RackSwitch in a standard 19-inch
equipment rack. For information about mounting the switch in other rack types, see
the following sections:
v “Installing the RackSwitch in an IBM iDataPlex rack” on page 22
v “Installing the RackSwitch in an IBM System x or Power rack” on page 25
The following parts come in the standard mounting kit.
Attention:The rack-mounting frame may not be able to support the weight of the
networking switch with only the front post mounting brackets (2-post application). If
the switch has an undesirable amount of sag, it is recommended to use a 4-post
mounting kit.
Attention:For earthquake stability, mount the switch in a 4-post rack.
Chapter 2. Installing the RackSwitch and options19
Page 34
DANGER
Rack-mounted devices are not to be used as shelves or work spaces.
(L002)
To install the RackSwitch in a standard equipment rack, complete the following
steps:
1. Locate and record the product switch information to configure and register your
product and set aside. See “Before installing the RackSwitch” on page 15.
Note: If this switch is a replacement switch, copy the product information from
the original switch onto the RID label that is shipped with replacement
switch and affix the new label to the bottom of the new switch.
2. Use the M4 screws to attach a mounting bracket to each side of the switch.
Torque the screws to approximately 2.0 newton-meters (Nm) +/- 0.1 Nm (17.7
inch-pounds).
3. Slide the switch into the rack.
4. Use the M6 screws, washers, and clip nuts (or cage nuts) to secure the switch
unit to the rack. Torque the screws to approximately 5.7 Nm +/- 0.1 Nm (50
inch-pounds).
20IBM System Networking RackSwitch G8264CS: Installation Guide
6
5
Page 35
3
2
1
5. Connect all cables.
6. Initialize the switch, see Chapter 4, “Initializing the RackSwitch,” on page 49.
Attention:If this is a switch replacement, make sure the vital product data
(VPD) is updated to avoid losing the licensed electronic entitlement data of the
RackSwitch. For more information, see “Configuring Vital Product Data after a
switch replacement” on page 46.
Chapter 2. Installing the RackSwitch and options21
Page 36
Installing the RackSwitch in an IBM iDataPlex rack
This section describes how to install the RackSwitch in an IBM iDataPlex rack. The
IBM iDataPlex mounting kit allows the switch to be mounted either vertically or
horizontally. For information about mounting the switch in other rack types, see the
following sections:
v “Installing the RackSwitch in a standard equipment rack” on page 19
v “Installing the RackSwitch in an IBM System x or Power rack” on page 25
The iDataPlex rack mount kit must be purchased separately.
The following table lists the parts included in the iDataPlex mounting kit.
Attention:The rack-mounting frame may not be able to support the weight of the
networking switch with only the front post mounting brackets (2-post application). If
the switch has an undesirable amount of sag, it is recommended to use a 4-post
mounting kit.
Attention:For earthquake stability, mount the switch in a 4-post rack.
DANGER
Rack-mounted devices are not to be used as shelves or work spaces.
(L002)
To install the RackSwitch in an iDataPlex rack, complete the following steps:
1. Locate and record the product switch information to configure and register your
product and set aside. See “Before installing the RackSwitch” on page 15.
22IBM System Networking RackSwitch G8264CS: Installation Guide
Page 37
Note: If this switch is a replacement switch, copy the product information from
the original switch onto the RID label that is shipped with replacement
switch and affix the new label to the bottom of the new switch.
2. Use the M4 screws to attach front and rear mounting brackets to each side of
the switch unit. Torque the screws to approximately 2 newton-meters (Nm) +/-
0.1 Nm (17.7 inch-pounds).
1
7
6
5
3. Use the M6 washers and screws to mount the switch unit into the rack. Torque
the screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).
4
2
3
4. Slide the RackSwitch into the rack.
Chapter 2. Installing the RackSwitch and options23
Page 38
5. Use the M6 washers, screws, and clip nuts to attach the alignment plate. Torque
the screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).
4
2
3
8
10
6. Connect all cables.
7. Initialize the switch, see Chapter 4, “Initializing the RackSwitch,” on page 49.
Attention:If this is a switch replacement, make sure the vital product data
(VPD) is updated to avoid losing the licensed electronic entitlement data of the
RackSwitch. For more information, see “Configuring Vital Product Data after a
switch replacement” on page 46.
24IBM System Networking RackSwitch G8264CS: Installation Guide
Page 39
Installing the RackSwitch in an IBM System x or Power rack
This section describes how to install the RackSwitch in an IBM System Networking
adjustable 19” 4-post rail rack (for Power and System x racks). For information
about mounting the RackSwitch in other rack types, see the following sections:
v “Installing the RackSwitch in a standard equipment rack” on page 19
v “Installing the RackSwitch in an IBM iDataPlex rack” on page 22
The IBM System Networking adjustable 19” 4-post rail mount kit parts must be
purchased separately.
The following table lists the parts included in the IBM System Networking adjustable
19” 4-post rail kit .
Table 14. IBM System Networking adjustable 19” 4-post rail mount kit parts
Rack-mounted devices are not to be used as shelves or work spaces.
(L002)
To install the RackSwitch in an IBM System Networking adjustable 19” 4-post rail
rack (for Power and System x racks), complete the following steps:
1. Locate and record the product switch information to configure and register your
product and set aside. See “Before installing the RackSwitch” on page 15.
Chapter 2. Installing the RackSwitch and options25
Page 40
Note: If this switch is a replacement switch, copy the product information from
the original switch onto the RID label that is shipped with replacement
switch and affix the new label to the bottom of the new switch.
2. Use the M4 screws to attach the front mounting brackets to each side of the
switch. Torque the screws to approximately 2.0 newton-meters (Nm) +/- 0.1 Nm
(17.7 inch-pounds).
9
9
1
7
3. Use the M6 screws, washers, and clip nuts are used to connect the front
mounting brackets to the front and rear posts in the rack. Torque the screws to
approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).
6
4
4. Slide the rear mounting brackets into the slots available on the front mounting
brackets.
26IBM System Networking RackSwitch G8264CS: Installation Guide
2
Page 41
SEE STEP 5
10
11
5. Use the M6 washers, screws, and clip nuts to attach the filler plate to the rear
mounting brackets. Torque the screws to approximately 5.7 Nm +/- 0.1 Nm (50
inch-pounds).
8
4
2
6
6. Use the M3 screws to secure the rear brackets to the front brackets. Torque the
screws to approximately 1.1 Nm +/- 0.1 Nm (10 inch-pounds).
9
3
10 11
Chapter 2. Installing the RackSwitch and options27
Page 42
7. Connect all the cables.
8. Initialize the switch, see Chapter 4, “Initializing the RackSwitch,” on page 49.
Attention:If this is a switch replacement, make sure that the vital product
data (VPD) is updated to avoid losing the licensed electronic entitlement data of
the RackSwitch. For more information, see “Configuring Vital Product Data after
a switch replacement” on page 46.
Installing the 1U air duct option
The RackSwitch supports an optional 1U air duct to maximize air flow conditions in
a 19" rack. For 1U air duct option part numbers, see the Chapter 6, “Replaceable
switch parts,” on page 57 section.
Mounting kit components
The 1U air duct option ships with:
v One 1U air duct unit
v One 1U air duct mechanical assembly kit
v One power cord
7
1
The following table lists the parts included with the 1U air duct mounting kit.
28IBM System Networking RackSwitch G8264CS: Installation Guide
Page 43
Table 15. 1U air duct mounting kit (continued)
Item numberDescriptionQuantity
7Screw, slotted, M3.5, 7 mm,
flanged hex head
6
Attention:The rack-mounting frame may not be able to support the weight of the
networking switch with only the front post mounting brackets (2-post application). If
the switch has an undesirable amount of sag, it is recommended to use a 4-post
mounting kit.
Attention:For earthquake stability, mount the switch in a 4-post rack.
DANGER
Rack-mounted devices are not to be used as shelves or work spaces.
(L002)
To install the 1U air duct option in a 19" rack, complete the following steps.
1. Loosen and remove the mounting screws from the both sides of the mounting
rail and set aside to reuse to secure the foam carrier.
Foam carrier snug against rear of unit
Reuse mounting screws
Half shear
Mounting screws
2. Place the half shears on the rear side of the foam carriers and use the M3.5
mounting rail screws to secure the foam carrier assemblies snugly against the
rear of the RackSwitch unit. Torque the screws to approximately 1.1 Nm (10
inch-pounds).
Note: There are additional M3.5 screws in the air duct assembly kit.
Chapter 2. Installing the RackSwitch and options29
Page 44
3. Plug the power cords into their respective RackSwitch power cord connectors
and using the tie wraps, secure the power cords to the mounting rails.
Power connection
Tie wraps
Power connection
Tie wraps
4. Use M6 screws to secure the air duct brackets to the mounting rails. Torque the
screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).
Air duct mounting bracket
M6 screws
M3.5 screws
5. Use the M3.5 screws to secure the air duct mounting bracket to the rack
chassis. Torque the screws to approximately 1.1 Nm (10 inch-pounds).
6. Gently slide the air duct unit side flanges into the card guides until the unit is
seated firmly. Make sure that the foam strip is oriented on top.
30IBM System Networking RackSwitch G8264CS: Installation Guide
Page 45
Foam
Card guides
Side flanges
M4
thumbscrews
7. Use the two M4 thumbscrews to secure the air duct unit to the air duct brackets.
For more information about removing the 1U air duct option, see “Removing the 1U
air duct option” on page 45.
Chapter 2. Installing the RackSwitch and options31
Page 46
Installing an SFP, SFP+, QSFP+, and Omni Port transceiver
The IBM System Networking RackSwitch G8264CS supports copper and optical
transceivers. For the available transceivers for the switch, see https://www-
To install a transceiver, see the following sections:
v “Installing an SFP copper transceiver”
v “Installing an SFP optical transceiver” on page 33
v “Installing an SFP+ optical transceiver” on page 34
v “Installing a QSFP+ optical transceiver” on page 35
v “Installing a transceiver in the Omni Port” on page 35
Installing an SFP copper transceiver
The SFP copper transceiver provides an RJ-45 connector that accepts a standard 1
Gb cable.
To install an SFP copper transceiver in an SFP+ port on the switch unit, complete
the following steps.
Note: To avoid damage to the cable or the SFP transceiver, do not connect the
cable before you install the transceiver.
1. Remove the safety cap and pull the locking lever into the down (unlocked)
position.
2. Insert the transceiver into the port until it clicks into place. Use minimal pressure
when you insert the transceiver into the slot. Do not use excessive force when
you insert the transceiver; you can damage the transceiver or the SFP slot.
The transceiver has a mechanical guide key to prevent you from inserting the
transceiver incorrectly.
3. Pull up the locking lever to lock the transceiver into place.
4. Connect the cable.
To remove a SFP copper transceiver, disconnect the cable, and pull down the
locking lever to release the transceiver. After you remove the transceiver,
replace the safety cap.
32IBM System Networking RackSwitch G8264CS: Installation Guide
Page 47
Installing an SFP optical transceiver
The SFP optical transceiver provides two fiber-optic cable connectors for connecting
to external ports.
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of an optical fiber cable or open
receptacle. (C027)
To install an SFP optical transceiver in an SFP+ slot on the switch unit, complete
the following steps.
Note: To avoid damage to the cable or the SFP transceiver, do not connect the
cable before you install the transceiver.
1. Remove the safety cap and pull the locking lever into the down (unlocked)
position.
2. Insert the transceiver into the port until it clicks into place. Use minimal pressure
when you insert the transceiver into the slot. Do not use excessive force when
you insert the transceiver; you can damage the transceiver or the SFP slot.
The transceiver has a mechanical guide key to prevent you from inserting the
transceiver incorrectly.
3. Pull up the locking lever to lock the transceiver into place.
4. Connect the fiber-optic cable.
To remove a SFP optical transceiver, disconnect the fiber-optic cable, and pull
down the locking lever to release the transceiver. After you remove the
transceiver, replace the safety cap.
Chapter 2. Installing the RackSwitch and options33
Page 48
Installing an SFP+ optical transceiver
The SFP+ ports accept supported SFP+ transceivers. The SFP+ optical transceiver
provides two fiber-optic cable connectors for connecting to external ports.
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of an optical fiber cable or open
receptacle. (C027)
To install an SFP+ optical transceiver in an SFP+ port, complete the following steps.
Note: To avoid damage to the cable or the SFP+ transceiver, do not connect the
cable before you install the transceiver.
1. Remove the safety cap and pull the locking lever into the down (unlocked)
position.
2. Insert the transceiver into the port until it clicks into place. Use minimal pressure
when you insert the transceiver into the slot. Do not use excessive force when
you insert the transceiver; you can damage the transceiver or the SFP+ slot.
The transceiver has a mechanical guide key to prevent you from inserting the
transceiver incorrectly.
3. Pull up the locking lever to lock the transceiver into place.
4. Connect the fiber-optic cable.
To remove a SFP+ optical transceiver, disconnect the fiber-optic cable, and pull
down the locking lever to release the transceiver. After you remove the
transceiver, replace the safety cap.
34IBM System Networking RackSwitch G8264CS: Installation Guide
Page 49
Installing a QSFP+ optical transceiver
The QSFP+ ports accept supported QSFP+ transceivers. The QSFP+ optical
transceiver provides an MTP cable connector for connecting to external ports.
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of a fiber optical cable or open
receptacle. (C027)
To install a QSFP+ optical transceiver in a QSFP+ port, complete the following
steps.
Note: To avoid damage to the cable or the transceiver, do not connect the cable
before you install the transceiver.
1. Remove the safety cap and pull the locking lever into the down (unlocked)
position.
2. Insert the transceiver into the port until it clicks into place. Use minimal pressure
when you insert the transceiver into the slot. Do not use excessive force when
you insert the transceiver; you can damage the transceiver or the QSFP+ slot.
The transceiver has a mechanical guide key to prevent you from inserting the
transceiver incorrectly.
3. Pull up the locking lever to lock the transceiver into place.
4. Connect the fiber-optic cable.
To remove a QSFP+ optical transceiver, disconnect the fiber-optic cable, and
pull down the locking lever to release the transceiver. After you remove the
transceiver, replace the safety cap.
Installing a transceiver in the Omni Port
The Omni Ports accept supported SPF+ optical transceivers and SFP transceivers,
for more information on the supported transceivers, see Chapter 6, “Replaceable
switch parts,” on page 57. The optical transceiver provides an MTP cable connector
for connecting to external ports.
Chapter 2. Installing the RackSwitch and options35
Page 50
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of a fiber optical cable or open
receptacle. (C027)
To install a transceiver in a Omni Port, complete the following steps.
Note: To avoid damage to the cable or the transceiver, do not connect the cable
before you install the transceiver.
1. Remove the safety cap and pull the locking lever into the down (unlocked)
position.
2. Insert the transceiver into the port until it clicks into place. Use minimal pressure
when you insert the transceiver into the slot. Do not use excessive force when
you insert the transceiver; you can damage the transceiver or the SFP+ slot.
The transceiver has a mechanical guide key to prevent you from inserting the
transceiver incorrectly.
3. Pull up the locking lever to lock the transceiver into place.
4. Connect the cable. Use a fiber-optic cable for an optical transceiver.
To remove the transceiver, disconnect the cable, and pull down the locking lever
to release the transceiver. After you remove the transceiver, replace the safety
cap.
36IBM System Networking RackSwitch G8264CS: Installation Guide
Page 51
Chapter 3. Removing and replacing the RackSwitch and
components
This chapter describes the how to remove and replace the RackSwitch chassis and
the associated RackSwitch components, such as, a fan module.
For more information to remove and replace individual components, see the
following sections.
v “Removing and replacing the RackSwitch chassis unit from a rack”
v “Removing a power supply module” on page 43
v “Replacing a power supply module” on page 43
v “Removing a fan module” on page 44
v “Replacing a fan module” on page 45
v “Removing the 1U air duct option” on page 45
v “Removing and replacing the main RackSwitch chassis unit” on page 46
Removing and replacing the RackSwitch chassis unit from a rack
This section describes how to remove the RackSwitch chassis unit from supported
equipment racks. For information about removing the RackSwitch from different
racks, see the following sections:
v “Removing the RackSwitch chassis from a standard equipment rack”
v “Removing the RackSwitch chassis from a System x or Power rack” on page 38
v “Removing the RackSwitch chassis from an iDataPlex rack” on page 41
Removing the RackSwitch chassis from a standard equipment rack
To remove the RackSwitch from a standard equipment rack, complete the following
steps:
1. Disconnect all cables.
2. Loosen and remove the M6 screws, washers, and clip nuts (or cage nuts) to
remove the switch unit from the rack.
4. Loosen and remove the M4 screws attaching the mounting bracket on each side
of the switch.
6
5
Removing the RackSwitch chassis from a System x or Power rack
To remove the RackSwitch from a System x rack or power rack, complete the
following steps:
1. Disconnect all the cables.
2. Loosen and remove the M3 screws that secure the rear brackets to the front
brackets.
9
3
10 11
3. Loosen and remove the M6 washers, screws, and clip nuts that attach the filler
plate to the rear mounting brackets.
38IBM System Networking RackSwitch G8264CS: Installation Guide
Page 53
8
4
2
6
4. Slide the rear mounting brackets out of the slots available on the front mounting
brackets.
SEE STEP 5
10
11
5. Loosen and remove the M6 screws, washers, and clip nuts are used to connect
the front mounting brackets to the front and rear posts in the rack.
Chapter 3. Removing and replacing the RackSwitch and components39
Page 54
4
2
6. Slide the RackSwitch out of the rack.
6
40IBM System Networking RackSwitch G8264CS: Installation Guide
Page 55
7. Loosen and remove the M4 screws that attach the front mounting brackets to
each side of the switch.
9
1
7
Removing the RackSwitch chassis from an iDataPlex rack
To remove the RackSwitch from the iDataPlex rack, complete the following steps:
1. Disconnect all cables.
2. Loosen and remove the M6 washers, screws, and clip nuts that attach the
alignment plate.
9
4
2
3
8
10
3. Loosen and remove the M6 washers and screws that mount the switch unit into
the rack.
Chapter 3. Removing and replacing the RackSwitch and components41
Page 56
4
2
3
4. Slide the RackSwitch out of the rack.
5. Loosen and remove the M4 screws that attach front and rear mounting brackets
to each side of the switch unit.
6
Removing and replacing a power supply module
The IBM System Networking RackSwitch G8264CS operates with two active power
supply modules. You can replace a hot-swap power supply module without
powering off the switch or disrupting switch functions.
Two power supplies are required for normal operation. The switch continues to
operate when there is one failed power supply. If one power supply fails, the power
LED and blue LED flashes and the switch sends an error message. For correct
airflow, both power supply slots must be populated with either a power supply
module or a blank module.
Each AC power supply module has a power cord for connection to an AC power
outlet.
7
1
5
42IBM System Networking RackSwitch G8264CS: Installation Guide
Page 57
Each power supply module has three LEDs that are visible from the rear panel. The
following table describes the LEDs.
Table 16. Power supply module LEDs
LED statusDescription
OK
GreenDC output power is present.
OffDC output power is not present.
Service(!)
AmberPower supply or fan module failure.
OffPower supply and fan modules are
~ AC Input
GreenAC power is OK.
OffNo power. Output is disabled or input power
Removing a power supply module
To remove a power supply module, complete the following steps:
1. Remove the power cord from the power connector.
2. Press the release latch on the left side of the power supply module, and slide
the module out of the slot.
operational.
is out of operating range.
Attention:Do not leave the power-supply slot empty for more than 90
seconds while the switch is operating.
Replacing a power supply module
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
To replace an AC power supply module, complete the following steps:
Chapter 3. Removing and replacing the RackSwitch and components43
Page 58
1. Insert the power supply module into the power-supply slot, and gently push it
into the slot until it latches. Each power supply module has a mechanical guide
key to prevent you from inserting the module incorrectly.
2. Connect the power cord to the power supply module and to an AC power
source.
3. Turn on the power at the power source.
4. Make sure that the power supply OK and AC LEDs are green.
Removing and replacing a fan module
The IBM System Networking RackSwitch G8264CS contains up to four hot-swap
fan modules. Four fan modules are required for high availability operation.
The switch continues to operate when there is one failed fan module. If one fan
fails, the switch sends an error message. If a second fan fails, the switch sends an
error message, writes a failure log to flash memory, and shuts down.
Each fan module has a green LED that is visible from the rear panel. The LED
shows the status of the fan module, as follows:
Table 17. Fan status LEDs
LED statusDescription
LitFans are operational.
OffThe switch has no power.
FlashingFan speed has failed. Replace the fan module.
Removing a fan module
To remove a fan module, complete the following steps:
1. Loosen the retainer screw.
2. Grasp the extractor handle and gently pull the fan module from the slot.
44IBM System Networking RackSwitch G8264CS: Installation Guide
Page 59
Attention:Replace the fan module within 5 minutes to avoid overheating the
switch.
Replacing a fan module
To replace a fan module, complete the following steps:
1. If necessary, remove the filler plate from the appropriate slot. Loosen the
retainer screws and slide the filler plate out of the slot.
2. Remove the fan module from the antistatic shielded bag.
3. Slide the fan module into the card guides in the open slot and gently push it all
the way into the slot, so that it firmly engages with the connector (see the
illustration). Each fan module has a mechanical guide key to prevent you from
inserting the module incorrectly.
4. Tighten the retaining screw on the fan module. Torque the screw to
approximately 0.5 Nm (4 inch-pounds).
Removing the 1U air duct option
To remove the 1U air duct option from a 19" rack, complete the following steps.
1. Loosen the two M4 thumbscrews securing the air duct unit to the air duct
brackets.
M4
thumbscrews
2. Slide the air duct unit out of the rack.
To return the component to customer service for replacement, see Appendix A,
“Getting help and technical assistance,” on page 65, to help you gather all the
Chapter 3. Removing and replacing the RackSwitch and components45
Page 60
required information that is necessary to return a component. After you remove the
component, securely pack the component for shipping.
For instructions to replace the air duct, see “Installing the 1U air duct option” on
page 28.
Removing and replacing the main RackSwitch chassis unit
When replacing a RackSwitch chassis unit, all internal component must also be
removed from the chassis and replaced in the new chassis. The RackSwitch
operates with one or two active power supplies, up to four fan modules, and an
optional air duct unit.
When you remove a RackSwitch unit from the rack, record the product MTM
number and serial number to use for the replacement switch, see “Before installing
the RackSwitch” on page 15 to locate the product information labels on the switch
chassis or “Configuring Vital Product Data after a switch replacement” to use an
interface to display the product information for the RackSwitch.
Before you replace the RackSwitch chassis, you must remove and replace the
separate components. For more information about removing and replacing
RackSwitch components, see the following sections:
v “Removing and replacing a power supply module” on page 42
v “Removing and replacing a fan module” on page 44
To return the chassis to customer service for replacement, see Appendix A, “Getting
help and technical assistance,” on page 65, to help you gather all the required
information that is necessary to return a component. After you remove the chassis
unit, securely pack the RackSwitch unit for shipping.
To replace the RackSwitch chassis in the rack, see the following procedures and
perform them in the order in which they are listed.
v “Replacing a power supply module” on page 43
v “Replacing a fan module” on page 45
v Chapter 2, “Installing the RackSwitch and options,” on page 15
Configuring Vital Product Data after a switch replacement
After you replace a RackSwitch, you must update the new switch with the VPD of
the RackSwitch being removed to avoid losing the licensed electronic entitlement
data of the RackSwitch. The VPD includes the model and serial number of the
switch. For more information on locating the VPD, see “Before installing the
RackSwitch” on page 15.
To update the VPD on a new switch, complete the following steps.
1. Log in to the switch and in the CLI mode, type
RS G8264>ibmnos
2. At the Password prompt, enter the switch password, and press Enter. The
default password is admin.
3. In the main menu, enter the MTM number for the replacement switch. For
example:
46IBM System Networking RackSwitch G8264CS: Installation Guide
Page 61
/boot/mtm 1611-11E
where 1611-11E is the MTM of the unit that is being replaced
4. Enter the serial number for the replacement switch. For example:
/boot/esn 1000001
where 1000001 is the serial number of the unit that is being replaced.
5. Reset the switch using the following command:
/boot/reset
6. When prompted to confirm the reset, enter y. The switch reboots.
7. After the switch reboots, at the command prompt, verify that the VPD
information is correct by issuing the show sys-info command using the ISCLI
interface or the /info/sys/general command using MenuCLI interface.
ISCLI interface output example:
show sys-info
System Information at 13:41:04 Fri Jan 20, 2011
Time zone: America/US/Pacific
Daylight Savings Time Status: Disabled
IBM System Networking RackSwitch G8264CS
Switch has been up for 0 days, 17 hours, 10 minutes and 45 seconds.
Last boot: 20:41:01 Thu Jan 19, 2011 (power cycle)
MAC address: fc:cf:62:9d:2b:00 IP (If 1) address: 0.0.0.0
Management Port MAC Address: fc:cf:62:9d:2b:fe
Management Port IP Address (if 128): 203.203.21.2
Hardware Revision: 0
Hardware Part No: BAC-000*a*00
Switch Serial No: US7C45t78
Manufacturing date:
Software Version 6.6.0 (FLASH image1), active configuration.
Temperature Mother Top: 34 C
Temperature Mother Bottom: 38 C
Temperature Daughter Top: 35 C
Temperature Daughter Bottom: 37 C
Warning at 70 C and Recover at 100 C
Fan 1 in Module 1: RPM=17647 PWM=255(100%) Front-To-Back
Fan 2 in Module 1: RPM= 9310 PWM=255(100%) Front-To-Back
Fan 3 in Module 2: RPM=17419 PWM=255(100%) Front-To-Back
Fan 4 in Module 2: RPM= 9326 PWM=255(100%) Front-To-Back
Fan 5 in Module 3: RPM=17197 PWM=255(100%) Front-To-Back
Fan 6 in Module 3: RPM= 9523 PWM=255(100%) Front-To-Back
Fan 7 in Module 4: RPM=17252 PWM=255(100%) Front-To-Back
Fan 8 in Module 4: RPM= 9490 PWM=255(100%) Front-To-Back
System Fan Airflow: Front-To-Back
Power Supply 1: Vin Fault
Power Supply 2: OK
Or
MenuCLI interface output example:
/info/sys/general
Chapter 3. Removing and replacing the RackSwitch and components47
Page 62
System Information at 0:16:42 Wed Jan 3, 2012
Time zone: America/US/Pacific
Daylight Savings Time Status: Disabled
IBM System Networking RackSwitch G8264CS
Switch has been up 5 days, 2 hours, 16 minutes and 42 seconds.
Last boot: 0:00:47 Wed Jan 3, 2012 (reset from console)
MAC address: 00:00:00:00:00:00 IP (If 1) address: 0.0.0.0
Internal Management Port MAC Address: 00:00:00:00:00:ef
Internal Management Port IP Address (if 128): 9.43.95.121
External Management Port MAC Address: 00:00:00:00:00:fe
External Management Port IP Address (if 127):
Software Version 7.5.0 (FLASH image2), active configuration.
Hardware Part Number: 46C7193
Hardware Revision: 05
Serial Number: PROTO2C04E
Manufacturing Date: 43/08
PCBA Part Number: BAC-00072-00
PCBA Revision: 0
PCBA Number: 00
Board Revision: 05
PLD Firmware Version: 1.3
Temperature Warning: 26 C (Warn at 60 C/Recover at 55 C)
Temperature Shutdown: 27 C (Shutdown at 65 C/Recover at 60 C)
Temperature Inlet: 23 C
Temperature Exhaust: 26 C
Power Consumption: 42.570 W (12.000 V, 3.543 A)
Switch is in I/O Module Bay 1
For more information about using the switch interface, see the Configuration
guide for your interface.
48IBM System Networking RackSwitch G8264CS: Installation Guide
Page 63
Chapter 4. Initializing the RackSwitch
When you supply power to the RackSwitch, the switch initializes automatically.
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
or
1
2
!
1
2
The following LEDs indicate the overall system status:
v Power Supply: Steady green if both power cords are connected, flashing green if
only one power cord is connected.
v Service(!):Offifthesystem is OK, flashing if service is required.
Use the mini-USB console cable to connect the RS-232 serial port on the switch
unit front panel to a terminal or a computer running a terminal emulation program.
You can access the command-line interface to perform initial configuration tasks.
To access the switch CLI and perform initial configuration tasks, use one of the
following methods:
v Connect an Ethernet cable to the RJ-45 management port and use Telnet,
SNMP, or a Web browser to access the CLI through the IP address provided by
the network’s DHCP server.
v Connect the mini-USB console cable to the RS-232 serial port on the switch
unit’s front panel, and use a terminal or a computer running a terminal emulation
program to access the switch CLI.
The console port terminal-emulation requirements are as follows:
v Default baud rate = 9,600 bps
v Character size = 8 characters
v Parity = none
v Stop bits = 1
v Data bits = 8
v Flow control = none
The switch performs initial self tests, and displays the password prompt, similar to
the following screen:
Memory Test ................................
Production Mode
PPCBoot 0.0.0.10 (new flash)
Memory Test (0x00) .............................PASSED
...
IBM System Networking RS G8264CS
Jan 1 00:01:27 2012:
NOTICE-5:Interface Oper Status Indication - Port 7 State UP
Password:
At the Password: prompt, enter the switch password, and press Enter. The default
password is admin.
Default configuration
The switch software contains default factory-loaded configuration files. The default
configuration is part of the software; it cannot be deleted or changed. The default
settings allow the switch to perform basic functions with minimal effort by the
system administrator. DHCP is enabled by default on the management interfaces
and BOOTP is enabled by default on interface 1. If there is no DHCP offer received,
the device uses the default Mgmt _IP address (192.168.50.50/24). This address is
overwritten when a DHCP/BOOTP address is received for that interface. If
DHCP/BOOTP is enabled and there is no static address configured for
DHCP/BOOTP requests will continue to be sent. This feature does not change
existing DHCP/BOOTP functionality. See the following initial configuration example:
50IBM System Networking RackSwitch G8264CS: Installation Guide
Page 65
RS G8264CS# show inter ip
Interface information:
1: IP4 192.168.49.50255.255.255.0192.168.49.255, vlan 1, up
128: IP4 192.168.50.50255.255.255.0192.168.50.255, vlan 4095, up
! interface ip 1
! addr <default>
! enable
! interface ip 128
!addr <default>
!enable
RS G8264CS(config)#system dhcp?
mgt dhcp on mgt port
RS G8264CS(config)#system dhcp mgt
Warning: Enabling dhcp will overwrite IP interface 128 and IP gateway 4 configurations.
RS G8264CS#show inter ip
Interface information:
1: IP4 192.168.49.50255.255.255.0192.168.49.255, vlan 1, up
128: IP4 192.168.50.50255.255.255.0192.168.50.255, vlan 4095, up
Configuring an IP interface
To manage the switch using Telnet, SNMP, or a web browser, you must configure
an IP interface. Configure the following IP parameters:
v IP address
v Subnet mask
v Gateway address
1. Log on to the switch. At the initial prompt,
Select Command Line Interface mode (ibmnos-cli/iscli):
3. Configure an IP interface, subnet mask, and VLAN assignment. Enable the
interface.
RS G8264CS (config-ip-if)# ip address 10.10.10.2 (example IP address)
RS G8264CS (config-ip-if)# ip netmask 255.255.255.0
RS G8264CS (config-ip-if)# vlan 1
RS G8264CS (config-ip-if)# enable
RS G8264CS (config-ip-if)# exit
4. Configure the default gateway. Enable the gateway.
RS G8264CS (config)# ip gateway 1 address 10.10.10.1 (example gateway address)
RS G8264CS (config)# ip gateway 1 enable
After you configure the IP address for your switch and you have an existing
network connection, you can use the Telnet program from an external
management station to access and control the switch. The management station
and your switch must be on the same IP subnet.
Chapter 4. Initializing the RackSwitch51
Page 66
Updating firmware
If firmware and documentation updates are available, you can download them from
http://www.ibm.com/supportportal/. The switch might have features that are not
described in the documentation that comes with the switch, and the documentation
might be updated occasionally to include information about those features, or
technical updates might be available to provide additional information that is not
included in the switch documentation.
Configuration settings are lost during a firmware update. Before updating the
firmware, save a copy of the configuration on a separate device. In the event of a
failed update, the saved configuration can be restored. For more information about
the configuration file, see the Application Guide and Command Reference for the
switch.
Attention:Installing the wrong firmware update might cause the network switch to
malfunction. Before you install a firmware, read any readme and change history
files that are provided with the downloaded update. These files contain important
information about the update and the procedure for installing the update, including
any special procedure for updating from an early firmware version to the latest
version.
The RackSwitch supports a command-line interface (CLI) that you can use to
configure and control the switch over the network using the Telnet program. You
can use the CLI to perform many basic network management functions. In
addition, you can configure the switch for management by using an
SNMP-based network management system or a web browser.
For more information about using the CLI, see the Command Reference for the
IBM System Networking RackSwitch G8264CS.
To check for firmware updates, go to http://www.ibm.com/supportportal/. For
firmware updates, click Downloads.
Note: Changes are made periodically to the IBM website. Procedures for locating
firmware and documentation might vary slightly from what is described in this
document.
Using the Boot Management menu
The Boot Management menu enables you to switch the software image, reset the
switch to factory defaults, or to recover from a failed software download.
You can interrupt the boot process and enter the Boot Management menu from the
serial console port. When the system displays Memory Test, press Shift+B. The
Boot Management menu is displayed.
Please choose your menu option: 1
Current boot image is 1. Enter image to boot: 1 or 2: 2
Booting from image 2
52IBM System Networking RackSwitch G8264CS: Installation Guide
Page 67
The Boot Management menu allows you to perform the following actions:
v To change the boot image, press 1 and follow the screen prompts.
v To change the configuration block, press 2, and follow the screen prompts.
v To perform an Xmodem download, press 3 and follow the screen prompts.
v To exit the Boot Management menu, press 4. The boot process continues.
Chapter 4. Initializing the RackSwitch53
Page 68
54IBM System Networking RackSwitch G8264CS: Installation Guide
Page 69
Chapter 5. Troubleshooting
This section contains basic troubleshooting information to help resolve problems
that might occur during installation and operation of the switch. If you have
problems accessing the switch or working with the software, see the CommandReference for your switch module.
For information about calling IBM for service, see Appendix A, “Getting help and
technical assistance,” on page 65.
System LED is not lit
Symptom: The power supply LED is not lit.
Solution: Check the power supply to make sure that there is a proper connection
to the power source. Make sure that power is available from the power source.
Port link LED is not lit
Symptom: The port link LED is not lit.
Solution 1: Check the port configuration in the software (see the Command
Reference for your switch module). If the port is configured with a specific speed or
duplex mode, check the other device to make sure that it is set to the same
configuration. If the switch port is set to auto-negotiate, make sure that the other
device is set to auto-negotiate.
Solution 2: Check the cables that connect the port to the other device. Make sure
that they are connected correctly. Make sure that you are using the correct cable
type.
Temperature sensor warning
Symptom: A temperature warning is displayed on the management console.
Solution: Make sure that the air circulation vents on the front, back, and sides of
the switch are free from obstruction by cables, panels, rack frames, or other
materials.
Make sure that all cooling fans inside the switch are running. A fan module LED
(rear panel) flashes if there is a failure of the fan. The following command displays
fan status:
show sys-info
If any fan stops during switch operation, contact Customer Support.
Switch does not initialize (boot)
Symptom: All the switch LEDs stay on, and the command prompt is not displayed
on the console.
Solution: The operating system might be damaged. Use the console port to
perform a serial upgrade of the switch software. See the Command Reference for
your switch module.
56IBM System Networking RackSwitch G8264CS: Installation Guide
Page 71
Chapter 6. Replaceable switch parts
The replaceable switch parts are Tier 1 customer replaceable units (CRUs).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation.
For information about the terms of the warranty, see the Warranty Information
document that comes with the switch. For more information about getting service
and assistance, see Appendix A, “Getting help and technical assistance,” on page
65.
Table 18. IBM System Networking RackSwitch G8264CS, Model 7309-XXX replaceable
parts
DescriptionModel
Switch unit, G8264CS
base (Front-to-rear)
Switch unit, G8264CS
base (Rear-to-front)
Power supplies
Front-to-rear air flow,
hot-swap 550W CFF
power supply spare
Rear-to-front air flow,
hot-swap 750W CFF
power supply spare
Fan modules
Front-to-rear air flow,
hot-swap fan assembly
spare
Rear-to-front air flow,
hot-swap fan assembly
spare
1.5 m CAT5 blue Ethernet40K8967
3 m CAT5 blue Ethernet40K8968
10 m CAT5 blue Ethernet40K8969
25 m CAT5 blue Ethernet40K8970
0.5 m IBM passive DAC SFP+00D6289
1 m, IBM passive DAC SFP+90Y9426
3 m, IBM passive DAC SFP+90Y9429
5 m, IBM passive DAC SFP+90Y9432
7 m IBM passive DAC SFP+00D6150
1 m, IBM active DAC SFP+46K6182
3 m, IBM active DAC SFP+46K6183
5 m, IBM active DAC SFP+ cable46K6184
1 m, IBM passive QSFP+ DAC (break out)49Y7930
3 m, IBM passive QSFP+ DAC (break out)49Y7931
5 m, IBM passive QSFP+ DAC (break out)49Y7932
1 m, IBM passive QSFP+-to-QSFP49Y7934
3 m, IBM passive QSFP+-to-QSFP49Y7935
5 m, IBM passive QSFP+-to-QSFP00D5809
7 m, IBM passive QSFP+-to-QSFP00D5812
10 m IBM QSFP+ MTP optical41V2458
30 m IBM QSFP+ MTP optical45D6369
1 m LC-LC Fiber (networking - optical)39M5699
5 m LC-LC Fiber (networking- optical)39M5700
25 m LC-LC Fiber (networking - optical)39M5701
Serial console kit (spare)94Y5444
Rail kits
IBM System Networking 19" Flexible 4-post00D6119
1U air duct, 483 mm00D6120
Chapter 6. Replaceable switch parts61
Page 76
For your safety, a power cord with a ground attachment plug is available to order
for use with this product. To avoid electrical shock, always use the power cord and
plug with a properly grounded outlet.
Power cords for this product that are used in the United States and Canada are
listed by Underwriter's Laboratories (UL) and certified by the Canadian Standards
Association (CSA).
For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified
cord set consisting of a minimum of 18 AWG, Type SVT or SJT, three-conductor
cord, a maximum of 15 feet in length and a parallel blade, grounding-type
attachment plug rated 15 amperes, 125 volts.
For units intended to be operated at 230 volts (U.S.): Use a UL-listed and
CSA-certified cord consisting of a minimum of 18 AWG, Type SVT or SJT,
three-conductor cord, a maximum of 15 feet in length and a tandem blade,
grounding-type attachment plug rated 15 amperes, 250 volts.
For units intended to be operated at 230 volts (outside the U.S.): Use a cord set
with a grounding-type attachment plug. The cord set should have the appropriate
safety approvals for the country in which the equipment will be installed.
Power cords for this product for a specific country or region are usually available
only in that country or region.
Table 20. Power and line cords (7309-xxx)
DescriptionOption Part number
Power cord, Australia, AC plug 10A/250V39Y7924
Power cord, Brazil, AC plug 16A/250VC39Y7929
Power cord, Canada39Y7931
Power cord, China, AC plug 16A/250V39Y7928
Power cord, Europe, AC plug 10A/250V39Y7917
Power cord, Europe (Denmark), AC plug 10A/250V39Y7918
Power cord, Europe (Israel) AC plug 10A/250V39Y7920
Power cord, Europe (Italy/Chili), AC plug 10A/250V39Y7921
Power cord, Europe (South Africa), AC plug 10A/250V 39Y7922
Power cord, Europe (Switzerland), AC plug 10A/250V 39Y7919
Power cord, India, AC plug 10A/250V39Y7927
Power cord, 2.8 m, Japan AC plug 12A/125V46M2593
Power cord, Korea, AC plug 10A/250V39Y7925
Power cord, UK, AC plug 13A/250V39Y7923
Power cord, Uruguay/Argentina, AC plug 16A/250V39Y7930
Power cord, 2.8 m, U.S., AC plug 10A/250V46M2592
Rack power cord, 1.5 m, 10A/100-250V, C13 to C1439Y7937
Rack power cord, 2.8 m, 10A, C13 to C1446M2982
Rack power cord, 4.3 m, 10A/100-250V, C13 to C1439Y7932
Rack power cord, 1.8 m, 10A/100-250V, 2
C13PM-IEC, 320-C14
43V6034
62IBM System Networking RackSwitch G8264CS: Installation Guide
Page 77
Table 20. Power and line cords (7309-xxx) (continued)
DescriptionOption Part number
Rack power cord, 2.8 m, 10A/230V, C13 to CEE7-VII
59Y8142
(Europe)
Line cord, 2.8 m, 10A/250V, C13 to IRAM 2073
39Y7930
(Argentina)
Line cord, 2.8 m, 10A/250V, C13-BS, 1363/A (UK)59Y8143
Table 21. Power and line cords (1455-64F)
DescriptionOption part number
Power cord, 4.3 m (14 ft), drawer to OEM
39M5096
PDU, 200-240V, 15A, IEC320/C13, PT# 5
Power cord, 4.3 m (14 ft), drawer to OEM
39M5200
PDU, 200-240V, 15A, IEC320/C13, PT# 59
Power cord, 3.05 m (10 ft), drawer to IBM
39M5392
PDU, 200-240V, 10A, IEC320/C20, PT# 59
Power cord, 4.3 m (14 ft) drawer to IBM
64IBM System Networking RackSwitch G8264CS: Installation Guide
Page 79
Appendix A. Getting help and technical assistance
If you need help, service, or technical assistance or just want more information
about IBM products, you will find a wide variety of sources available from IBM to
assist you. Use this information to obtain additional information about IBM and IBM
products, determine what to do if you experience a problem with your IBM system
or optional device, and determine whom to call for service, if it is necessary.
Before you call
Before you call, make sure that you have taken these steps to try to solve the
problem yourself:
v Check all cables to make sure that they are connected.
v Check the power switches to make sure that the system and any optional
devices are turned on.
v Check for updated firmware and operating-system device drivers for your IBM
product at www.ibm.com/support/fixcentral. The IBM Warranty terms and
conditions state that you, the owner of the IBM product, are responsible for
maintaining and updating all software and firmware for the product (unless it is
covered by an additional maintenance contract). Your IBM service technician will
request that you upgrade your software and firmware if the problem has a
documented solution within a software upgrade.
Opening a support request
To open a support call, complete the following steps.
1. Create a brief problem description and a prioritization for your support call.
2. Gather the required product information to provide to IBM Support. The serial
number and MTM (IBM 4-digit machine identifier) are on the product label and
will help IBM Support quickly provide a solution to your problem and ensure that
you receive the level of service for which you might have contracted.
3. Gather your hardware and software maintenance agreement contract numbers,
if applicable.
4. Gather other pertinent information such as error messages and logs.
You can determine the product MTM and serial number in the following ways:
v Locate the product information labels on the bottom of the switch, see “Before
installing the RackSwitch” on page 15.
v If the firmware is at 7.6.x.x or later, you can determine the machine type model
(MTM) and serial number through the interface. For more information on locating
the MTM and serial number (VPD) through the interface, see “Configuring Vital
Product Data after a switch replacement” on page 46.
After you gather your product information, you can submit a service request in
either of two ways:
v In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378) to open a
hardware report. See http://www.ibm.com/planetwide/ for additional support
telephone numbers.
v Go to http://www.ibm.com/support/entry/portal/Open_service_request/ to submit
an Electronic Service Request. Submitting an Electronic Service Request will
start the process of determining a solution to your problem by making the
pertinent information available to IBM Support quickly and efficiently. IBM service
technicians can start working on your solution as soon as you have completed
and submitted an Electronic Service Request.
For more information about Support Line and other IBM services, see
http://www.ibm.com/services/.
How to send Dynamic System Analysis data to IBM
Use the IBM Enhanced Customer Data Repository to send diagnostic data to IBM.
Before you send diagnostic data to IBM, read the terms of use at
http://www.ibm.com/de/support/ecurep/terms.html.
You can use any of the following methods to send diagnostic data to IBM:
v Standard upload: http://www.ibm.com/de/support/ecurep/send_http.html
v Standard upload with the system serial number: http://www.ecurep.ibm.com/
app/upload_hw
v Secure upload: http://www.ibm.com/de/support/ecurep/send_http.html#secure
v Secure upload with the system serial number: https://www.ecurep.ibm.com/
app/upload_hw
Using the documentation
Information about your IBM system and preinstalled software, if any, or optional
device is available in the documentation that comes with the product. That
documentation can include printed documents, online documents, readme files, and
help files. Also, some documents are available through the IBM Publications Center
at http://www.ibm.com/shop/publications/order/.
Getting help and information from the World Wide Web
IBM maintains pages on the World Wide Web where you can get the latest
technical information and download device drivers and updates. To access these
pages, go to http://www.ibm.com/supportportal/. .
Creating a personalized support web page
At http://www.ibm.com/support/mynotifications/, you can create a personalized
support web page by identifying IBM products that are of interest to you. From this
personalized page, you can subscribe to weekly email notifications about new
technical documents, search for information and downloads, and access various
administrative services.
66IBM System Networking RackSwitch G8264CS: Installation Guide
Page 81
Appendix B. Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the
products and services currently available in your area. Any reference to an IBM
product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product,
program, or service that does not infringe any IBM intellectual property right may be
used instead. However, it is the user's responsibility to evaluate and verify the
operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not give you any
license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Some states do not allow disclaimer of express or
implied warranties in certain transactions, therefore, this statement may not apply to
you.
Trademarks
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. IBM may make improvements and/or
changes in the product(s) and/or the program(s) described in this publication at any
time without notice.
Any references in this information to non-IBM websites are provided for
convenience only and do not in any manner serve as an endorsement of those
websites. The materials at those websites are not part of the materials for this IBM
product, and use of those websites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.
IBM, the IBM logo, and ibm.com are trademarks of International Business Machines
Corp., registered in many jurisdictions worldwide. Other product and service names
might be trademarks of IBM or other companies. A current list of IBM trademarks is
available on the web at “Copyright and trademark information” at
http://www.ibm.com/legal/copytrade.shtml.
Adobe and PostScript are either registered trademarks or trademarks of Adobe
Systems Incorporated in the United States and/or other countries.
Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc., in the
United States, other countries, or both and is used under license therefrom.
Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of
Intel Corporation or its subsidiaries in the United States and other countries.
Java and all Java-based trademarks and logos are trademarks or registered
trademarks of Oracle and/or its affiliates.
Linux is a registered trademark of Linus Torvalds in the United States, other
countries, or both.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in
the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other
countries.
Processor speed indicates the internal clock speed of the microprocessor; other
factors also affect application performance.
CD or DVD drive speed is the variable read rate. Actual speeds vary and are often
less than the possible maximum.
When referring to processor storage, real and virtual storage, or channel volume,
KB stands for 1024 bytes, MB stands for 1,048,576 bytes, and GB stands for
1,073,741,824 bytes.
When referring to hard disk drive capacity or communications volume, MB stands
for 1,000,000 bytes, and GB stands for 1,000,000,000 bytes. Total user-accessible
capacity can vary depending on operating environments.
Maximum internal hard disk drive capacities assume the replacement of any
standard hard disk drives and population of all hard disk drive bays with the largest
currently supported drives that are available from IBM.
Maximum memory might require replacement of the standard memory with an
optional memory module.
Each solid-state memory cell has an intrinsic, finite number of write cycles that the
cell can incur. Therefore, a solid-state device has a maximum number of write
cycles that it can be subjected to, expressed as “total bytes written” (TBW). A
device that has exceeded this limit might fail to respond to system-generated
commands or might be incapable of being written to. IBM is not responsible for
replacement of a device that has exceeded its maximum guaranteed number of
program/erase cycles, as documented in the Official Published Specifications for the
device.
IBM makes no representation or warranties regarding non-IBM products and
services that are ServerProven
of merchantability and fitness for a particular purpose. These products are offered
and warranted solely by third parties.
®
, including but not limited to the implied warranties
68IBM System Networking RackSwitch G8264CS: Installation Guide
Page 83
IBM makes no representations or warranties with respect to non-IBM products.
Support (if any) for the non-IBM products is provided by the third party, not IBM.
Some software might differ from its retail version (if available) and might not include
user manuals or all program functionality.
Particulate contamination
Attention:Airborne particulates (including metal flakes or particles) and reactive
gases acting alone or in combination with other environmental factors such as
humidity or temperature might pose a risk to the device that is described in this
document. Risks that are posed by the presence of excessive particulate levels or
concentrations of harmful gases include damage that might cause the device to
malfunction or cease functioning altogether. This specification sets forth limits for
particulates and gases that are intended to avoid such damage. The limits must not
be viewed or used as definitive limits, because numerous other factors, such as
temperature or moisture content of the air, can influence the impact of particulates
or environmental corrosives and gaseous contaminant transfer. In the absence of
specific limits that are set forth in this document, you must implement practices that
maintain particulate and gas levels that are consistent with the protection of human
health and safety. If IBM determines that the levels of particulates or gases in your
environment have caused damage to the device, IBM may condition provision of
repair or replacement of devices or parts on implementation of appropriate remedial
measures to mitigate such environmental contamination. Implementation of such
remedial measures is a customer responsibility.
Table 22. Limits for particulates and gases
ContaminantLimits
Particulatev The room air must be continuously filtered with 40%
atmospheric dust spot efficiency (MERV 9) according to
ASHRAE Standard 52.2
v Air that enters a data center must be filtered to 99.97%
efficiency or greater, using high-efficiency particulate air
(HEPA) filters that meet MIL-STD-282.
v The deliquescent relative humidity of the particulate
contamination must be more than 60%
v The room must be free of conductive contamination such
as zinc whiskers.
Gaseousv Copper: Class G1 as per ANSI/ISA 71.04-1985
v Silver: Corrosion rate of less than 300 Å in 30 days
1
ASHRAE 52.2-2008 - Method of Testing General Ventilation Air-Cleaning Devices forRemoval Efficiency by Particle Size. Atlanta: American Society of Heating, Refrigerating and
Air-Conditioning Engineers, Inc.
2
The deliquescent relative humidity of particulate contamination is the relative humidity at
which the dust absorbs enough water to become wet and promote ionic conduction.
3
ANSI/ISA-71.04-1985. Environmental conditions for process measurement and controlsystems: Airborne contaminants. Instrument Society of America, Research Triangle Park,
North Carolina, U.S.A.
1
.
2
.
3
Appendix B. Notices69
Page 84
Documentation format
The publications for this product are in Adobe Portable Document Format (PDF)
and should be compliant with accessibility standards. If you experience difficulties
when you use the PDF files and want to request a web-based format or accessible
PDF document for a publication, direct your mail to the following address:
Information Development
IBM Corporation
205/A015
3039 E. Cornwallis Road
P.O. Box 12195
Research Triangle Park, North Carolina 27709-2195
U.S.A.
In the request, be sure to include the publication part number and title.
When you send information to IBM, you grant IBM a nonexclusive right to use or
distribute the information in any way it believes appropriate without incurring any
obligation to you.
Telecommunication regulatory statement
This product may not be certified in your country for connection by any means
whatsoever to interfaces of public telecommunications networks.
Further certification may be required by law prior to making any such connection.
Contact an IBM representative or reseller for any questions.
Electronic emission notices
When you attach a monitor to the equipment, you must use the designated monitor
cable and any interference suppression devices that are supplied with the monitor.
Federal Communications Commission (FCC) statement
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference, in which case the user will be required to correct the
interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to
meet FCC emission limits. IBM is not responsible for any radio or television
interference caused by using other than recommended cables and connectors or by
unauthorized changes or modifications to this equipment. Unauthorized changes or
modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
70IBM System Networking RackSwitch G8264CS: Installation Guide
Page 85
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d'Industrie Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
Australia and New Zealand Class A statement
Attention:This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council
Directive 2004/108/EC on the approximation of the laws of the Member States
relating to electromagnetic compatibility. IBM cannot accept responsibility for any
failure to satisfy the protection requirements resulting from a nonrecommended
modification of the product, including the fitting of non-IBM option cards.
Attention:This is an EN 55022 Class A product. In a domestic environment this
product may cause radio interference in which case the user may be required to
take adequate measures.
Responsible manufacturer:
International Business Machines Corp.
New Orchard Road
Armonk, New York 10504
914-499-1900
European Community contact:
IBM Deutschland GmbH
Technical Regulations, Department M372
IBM-Allee 1, 71139 Ehningen, Germany
Tele: 0049 (0) 7032 15-2941
Email: lugi@de.ibm.com
Germany Class A statement
Deutschsprachiger EU Hinweis:
Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen
Verträglichkeit
Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG
zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit
in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein.
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu
installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM
empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für
die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der
IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne
Empfehlung der IBM gesteckt/eingebaut werden.
Appendix B. Notices71
Page 86
EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden:
“Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann im
Wohnbereich Funk-Störungen verursachen; in diesem Fall kann vom Betreiber
verlangt werden, angemessene Maßnahmen zu ergreifen und dafür aufzukommen.”
Deutschland: Einhaltung des Gesetzes über die
elektromagnetische Verträglichkeit von Geräten
Dieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeit
von Geräten (EMVG)”. Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG in
der Bundesrepublik Deutschland.
Zulassungsbescheinigung laut dem Deutschen Gesetz über die
elektromagnetische Verträglichkeit von Geräten (EMVG) (bzw. der
EMC EG Richtlinie 2004/108/EG) für Geräte der Klasse A
Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das
EG-Konformitätszeichen - CE - zu führen.
Verantwortlich für die Einhaltung der EMV Vorschriften ist der Hersteller:
International Business Machines Corp.
New Orchard Road
Armonk, New York 10504
914-499-1900
Der verantwortliche Ansprechpartner des Herstellers in der EU ist:
IBM Deutschland GmbH
Technical Regulations, Department M372
IBM-Allee 1, 71139 Ehningen, Germany
Tele: 0049 (0) 7032 15-2941
Email: lugi@de.ibm.com
Generelle Informationen:
Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022
Klasse A.
VCCI Class A statement
This is a Class A product based on the standard of the Voluntary Control Council for
Interference (VCCI). If this equipment is used in a domestic environment, radio
interference may occur, in which case the user may be required to take corrective
actions.
Japan Electronics and Information Technology Industries Association
(JEITA) statement
Japanese Electronics and Information Technology Industries Association (JEITA)
Confirmed Harmonics Guideline (products less than or equal to 20 A per phase).
72IBM System Networking RackSwitch G8264CS: Installation Guide
Page 87
Korea Communications Commission (KCC) statement
This is electromagnetic wave compatibility equipment for business (Type A). Sellers
and users need to pay attention to it. This is for any areas other than home.
Russia Electromagnetic Interference (EMI) Class A statement
People's Republic of China Class A electronic emission statement
Taiwan Class A compliance statement
Appendix B. Notices73
Page 88
74IBM System Networking RackSwitch G8264CS: Installation Guide