Note: Before using this information and the product it supports, read the Warranty Information document, the general information in
Appendix B, “Notices,” on page 67, and the Important Notices document that comes with the product. Read the IBM Safety Notices
and the License Agreement for Machine Code (LAMC) document on the IBM Documentation CD. Read the Environmental Noticesand User Guide on the IBM Environmental Notices CD.
Läs säkerhetsinformationen innan du installerar den här produkten.
Bu ürünü kurmadan önce güvenlik bilgilerini okuyun.
Important:
Each caution and danger statement in this document is labeled with a
number. This number is used to cross reference an English-language
caution or danger statement with translated versions of the caution or
danger statement in the Safety Information document.
For example, if a caution statement is labeled “D005,” translations for
that caution statement are in the Safety Information document under
“D005.”
Be sure to read all caution and danger statements in this document
before you perform the procedures. Read any additional safety
information that comes with the switch or optional device before you
install the device.
DANGER
Hazardous voltage, current, or energy levels are present inside any
component that has this label attached. Do not open any cover or barrier
that contains this label.
(L001)
DANGER
Rack-mounted devices are not to be used as shelves or work spaces.
(L002)
ivIBM System Networking RackSwitch G8264CS: Installation Guide
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
or
1
2
!
1
2
Safetyv
DANGER
An electrical outlet that is not correctly wired could place hazardous
voltage on the metal parts of the system or the devices that attach to the
system. It is the responsibility of the customer to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock. (D004)
viIBM System Networking RackSwitch G8264CS: Installation Guide
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication
cables are hazardous. To avoid a shock hazard:
v Connect power to this unit only with the IBM provided power cord. Do
not use the IBM provided power cord for any other product.
v Do not open or service any power supply assembly.
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
v The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
v Connect all power cords to a properly wired and grounded electrical
outlet. Ensure that the outlet supplies proper voltage and phase rotation
according to the system rating plate.
v Connect any equipment that will be attached to this product to properly
wired outlets.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3. Remove the signal cables from the connectors.
4. Remove all cables from the devices.
To connect:
1. Turn off everything (unless instructed otherwise).
2. Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
v Sharp edges, corners and joints may be present in and around the
system. Use care when handling equipment to avoid cuts, scrapes and
pinching.
(D005)
Safetyvii
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of a fiber optical cable or open
receptacle. (C027)
CAUTION:
This product contains a Class 1M laser. Do not view directly with optical
instruments. (C028)
viiiIBM System Networking RackSwitch G8264CS: Installation Guide
DANGER
Observe the following precautions when working on or around your IT rack
system:
v Heavy equipment—personal injury or equipment damage might result if
mishandled.
v Always lower the leveling pads on the rack cabinet.
v Always install stabilizer brackets on the rack cabinet.
v To avoid hazardous conditions due to uneven mechanical loading,
always install the heaviest devices in the bottom of the rack cabinet.
Always install servers and optional devices starting from the bottom of
the rack cabinet.
v Rack-mounted devices are not to be used as shelves or work spaces. Do
not place objects on top of rack-mounted devices.
v Each rack cabinet might have more than one power cord. Be sure to
disconnect all power cords in the rack cabinet when directed to
disconnect power during servicing.
v Connect all devices installed in a rack cabinet to power devices installed
in the same rack cabinet. Do not plug a power cord from a device
installed in one rack cabinet into a power device installed in a different
rack cabinet.
v An electrical outlet that is not correctly wired could place hazardous
voltage on the metal parts of the system or the devices that attach to the
system. It is the responsibility of the customer to ensure that the outlet
is correctly wired and grounded to prevent an electrical shock.
(R001 part 1 of 2)
Safetyix
CAUTION:
v Do not install a unit in a rack where the internal rack ambient temperatures
will exceed the manufacturer’s recommended ambient temperature for all
your rack-mounted devices.
v Do not install a unit in a rack where the air flow is compromised. Ensure
that air flow is not blocked or reduced on any side, front, or back of a unit
used for air flow through the unit.
v Consideration should be given to the connection of the equipment to the
supply circuit so that overloading of the circuits does not compromise the
supply wiring or overcurrent protection. To provide the correct power
connection to a rack, refer to the rating labels located on the equipment in
the rack to determine the total power requirement of the supply circuit.
v (For sliding drawers) Do not pull out or install any drawer or feature if the
rack stabilizer brackets are not attached to the rack. Do not pull out more
than one drawer at a time. The rack might become unstable if you pull out
more than one drawer at a time.
v (For fixed drawers) This drawer is a fixed drawer and must not be moved
for servicing unless specified by the manufacturer. Attempting to move the
drawer partially or completely out of the rack might cause the rack to
become unstable or cause the drawer to fall out of the rack.
(R001 part 2 of 2)
Important:
Important:
This product is also designed for IT power distribution systems with
phase-to-phase voltage of 230V.
Machinenlärminformations-Verordnung - 3. GPSGV, der höchste
Shalldruckpegel beträgt 70 dB (A) oder weniger.
xIBM System Networking RackSwitch G8264CS: Installation Guide
Contents
Safety ............................iii
Chapter 1. Introduction ......................1
The IBM Documentation CD....................1
Hardware and software requirements .................2
Related documentation ......................2
Notices and statements in this document................2
Federal Communications Commission (FCC) statement .........70
Industry Canada Class A emission compliance statement ........71
Avis de conformité à la réglementation d'Industrie Canada ........71
Australia and New Zealand Class A statement ............71
European Union EMC Directive conformance statement.........71
Germany Class A statement ...................71
VCCI Class A statement....................72
Japan Electronics and Information Technology Industries Association (JEITA)
statement .........................72
Korea Communications Commission (KCC) statement .........73
Russia Electromagnetic Interference (EMI) Class A statement.......73
People's Republic of China Class A electronic emission statement .....73
Taiwan Class A compliance statement ...............73
Index ............................75
xiiIBM System Networking RackSwitch G8264CS: Installation Guide
Chapter 1. Introduction
This Installation Guide provides information and instructions for installing, updating
the firmware, and solving problems for an IBM
G8264CS. For information about configuration and management of the converged
switch, see the Command Reference for the IBM System Networking RackSwitch
G8264CS and the product release notes.
The IBM System Networking RackSwitch G8264CS (converged switch) is a
rackable aggregation switch with unmatched line-rate Layer 2 and Layer 3
performance. The IBM System Networking RackSwitch G8264CS uses a
wire-speed, non-blocking switching fabric that provides simultaneous wire-speed
transport of Ethernet packets at low latency on all ports.
The IBM System Networking RackSwitch G8264CS contains thirty-six 10 GbE small
form-factor pluggable plus (SFP+) ports and four 40 GbE quad small form-factor
pluggable plus (QSFP+) ports, and twelve Omni Ports. Omni Port technology allows
the same port to be used as a 10 Gb Ethernet port (SFP+) or as a 4 Gbps or 8
Gbps Fibre Channel port. The SFP+ ports can be populated with optical or copper
transceivers, or Direct Attach Cables (DACs). The QSFP+ ports can be populated
with optical QSFP+ transceivers or DACs.
The IBM System Networking RackSwitch G8264CS provides support for Layer 2
and Layer 3 switching and routing, including Converged Enhanced Ethernet (CEE),
10 Gb Ethernet switching, Fibre Channel over Ethernet (FCoE) and FC/FCoE
capabilities NPV (N_Port Virtualization) Gateway, and Full Fabric FC/FCoE switch.
®
System Networking RackSwitch
™
You can manage the switch through the console port, or through a network
connection using Telnet, a web browser-based interface, or SNMP-based network
management software. For more information, see Chapter 4, “Initializing the
RackSwitch,” on page 49.
If documentation updates are available, you can download them from
http://www.ibm.com/supportportal/. The switch might have features that are not
described in the documentation that comes with the switch, and the documentation
might be updated occasionally to include information about those features, or
technical updates might be available to provide additional information that is not
included in the switch documentation.
To check for documentation updates,
1. Go to http://www.ibm.com/supportportal/ and click Documentation.
2. In the Quick find field enter the name of your product and press Enter.
Note: Changes are made periodically to the IBM website. Procedures for locating
firmware and documentation might vary slightly from what is described in this
document.
The IBM Documentation CD
The IBM Documentation CD contains documentation for your switch in Portable
Document Format (PDF).
The Documentation CD includes the product installation guide, safety document and
the License Agreement for Machine Code (LAMC) document. The EnvironmentalNotices CD includes the Environmental Notices for the product. To access these
documents:
v If you are using a Windows operating system, insert the CD into the CD or DVD
drive and from My Computer, double click the CD or DVD drive and select the
installation guide that supports your product.
v If you are using a Linux operating system, insert the CD into the CD or DVD
drive and run the following command from the mnt/cd directory, sh.linux.sh.
Select the installation guide that supports your product.
Double click on the Installation Guides directory and select the installation guide
that supports your product.
Hardware and software requirements
The IBM Documentation CD requires the following minimum hardware and
software:
v Microsoft Windows NT 4.0 (with Service Pack 3 or later), Windows 2000, or Red
Hat Linux.
v 100 MHz microprocessor.
v 32 MB of RAM.
v Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
systems.
Related documentation
The following related documentation is available at http://www.ibm.com/systems/
support/:
v IBM System Networking RackSwitch G8264CS Application Guide
v IBM System Networking RackSwitch G8264CS Menu-based Command
Reference
v IBM System Networking RackSwitch G8264CS ISCLI–Industry Standard CLI
Command Reference
v IBM System Networking RackSwitch G8264CS BBI Quick Guide
Notices and statements in this document
The caution and danger statements in this document are also in the multilingual
Safety Information document, which is on the IBM Documentation CD. Each
statement is numbered for reference to the corresponding statement in the SafetyInformation document.
The following notices and statements are used in this document:
v Note: These notices provide important tips, guidance, or advice.
v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
2IBM System Networking RackSwitch G8264CS: Installation Guide
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
RackSwitch G8264CS features
This section provides an overview of IBM System Networking RackSwitch G8264CS
features.
Performance
v 1.2 Tbps Ethernet throughput (full duplex), non-blocking switching architecture
v 100% Ethernet line rate
Management Features
v Clients
– Industry standard command-line interface (ISCLI)
– Browser-based Interface (BBI)
–System Networking Switch Center
v Protocols
– SNMP v1, v2, v3
– Remote Monitoring (RMON)
– Network Time Protocol (NTP) support
– DHCP
v Software upgrades
– Dual software images
– Upgrade via serial, browser, or TFTP
Software Features
v Security
– Secure interface login and password
– RADIUS and TACACS+
– SSH v2
– HTTPS Secure Browser-based interface
– Wire-speed filtering with Access Control Lists (ACLs)
v Layer 2
– 1024 VLANs (802.1Q), including Private VLANs
– Multi-link trunking, compatible with Cisco EtherChannel
– LACP (IEEE 802.3ad)
– Per VLAN Rapid Spanning Tree -- PVRST+
– Spanning Tree (802.1s), Multiple Spanning Tree (802.1s), Rapid Spanning
Tree (802.1w), with Fast Uplink Convergence
– 128 K forwarding database entries
v Layer 3
– Dynamic routing
- RIP v1, v2
- OSPF
- BGP
Chapter 1. Introduction3
– 128 configurable interfaces (static or DHCP)
– DHCP Relay
– IP forwarding
– IGMP Snooping v1, v2, v3
– 8 K ARP entries
– IPv6 host management
v Quality of service
– 802.1p priority queues
– Differentiated Services Code Point (DSCP) support
v Convergence
– Support for IBM vNIC (virtual Network Interface Card) Virtual Fabric Adapter
– Support for Converged Enhanced Ethernet (CEE) (PFC, ETS, DCBX)
v Availability
– Layer 2 failover
– Hot links
– VRRP
Major components
This section describes the IBM System Networking RackSwitch G8264CS hardware
components.
Hardware options
The following list provides an overview of G8264CS hardware:
v Switch unit
v Mounting hardware
v Hot-swap power supply (2)
v Hot-swap fans (4)
Switch unit
The switch unit is a 1U rack-mountable scalable switch. You can mount it in either
the horizontal or vertical direction.
The switch allows for flexible mounting, as follows:
v IBM System Networking RackSwitch G8264CS (front-to-rear) provides
vIBM System Networking RackSwitch G8264CS (rear-to-front) provides
Ports
The switch unit contains the following ports:
v Thirty-six 10 GbE SFP+ ports and twelve Omni Ports (which can be used as
v Four QSFP+ ports
– Standard 2-post rack mounting brackets and screws
®
– IBM iDataPlex
– IBM System-x 4-post rack mounting brackets and screws (purchased
separately)
front-to-rear airflow.
rear-to-front airflow.
SFP+ or FC ports)
rack mounting brackets and screws (purchased separately)
4IBM System Networking RackSwitch G8264CS: Installation Guide
v RJ-45 port management port
v USB port for mass storage
v RS-232 (mini USB) serial console port
The following illustrations show the ports and controls on the front and rear of the
switch.
Figure 1. IBM System Networking RackSwitch G8264CS front panel
Figure 2. IBM System Networking RackSwitch G8264CS front panel detail
Figure 3. IBM System Networking RackSwitch G80264CS rear panel
Reset button
The Reset button is recessed within a hole on the front panel. Use a straightened
paper clip or similar object to press the Reset button. The Reset button enables you
to reset the switch, as follows:
v Press Reset: The switch resets and reloads the configuration files.
v Press and hold Reset for five seconds: The switch resets and configures all
settings to the factory defaults.
Fans
Four hot-swap internal fans cool the switch unit and are required for normal
operation. If an individual fan fails, the other fans continue to run, and the switch
unit continues to operate normally. You can replace a hot-swap fan module while
the switch is operating.
Chapter 1. Introduction5
Fan operation and internal temperatures are monitored. If the air temperature
exceeds a threshold, the environmental monitor displays warning messages.
Note: If a fan module fails, the maximum operating temperature drops from 40°C to
35°C (104°F to 95°F).
The Service(!)LEDislitifthere is a failure of one or more fan modules. The
failed fan module LED (rear panel) flashes to indicate a failure.
AC power supply
The switch has two hot-swap AC power supplies, 550 W for front-to-rear or 750 W
for rear-to-front. Each internal power supply has an individual IEC 320 power
connector on the rear panel. The power cord attaches to a universal grounded AC
power source. You can replace a hot-swap power supply module without powering
off the switch or disrupting switch functions.
DANGER
Multiple power cords. This product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
or
1
2
!
1
2
6IBM System Networking RackSwitch G8264CS: Installation Guide
Switch ports
DANGER
An electrical outlet that is not correctly wired could place hazardous
voltage on the metal parts of the system or the devices that attach to the
system. It is the responsibility of the customer to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock. (D004)
Each power supply can be connected to a separate AC circuit to mitigate the risk of
down time during a power failure. When used in a redundant configuration, the dual
power supplies have a load-sharing capability that enables each power supply to
operate at approximately 50 percent of full load. Using redundant power can
minimize the power disruption during a power supply failure and extend the
expected lifetime of each power supply by operating normally in a conservative
power mode.
There is no power switch on the IBM System Networking RackSwitch G8264CS;
the switch unit powers up when power is supplied through the power cords.
The Power Supply LED indicates the status of the power supplies. The LED flashes
when only one power cord is connected, and is steady when both power cords are
connected.
The switch ports and port options are described in the following sections.
v “SFP+ ports”
v “QSFP+ ports” on page 8
v “Fibre Channel/Ethernet Omni Ports” on page 9
v “Console port” on page 9
v “USB port” on page 10
SFP+ ports
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of the controls or adjustments or performance of procedures other
than those specified herein might result in hazardous radiation exposure.
(C026)
Chapter 1. Introduction7
CAUTION:
Data processing environments can contain equipment transmitting on system
links with laser modules that operate at greater than Class 1 power levels. For
this reason, never look into the end of an optical fiber cable or open
receptacle. (C027)
Forty-eight 10 GbE SFP+ ports (twelve ports can be used as SPF+ Omni Ports) are
located on the front panel. These ports accept approved optical or copper SFP and
SFP+ transceivers and SFP+ active and passive DAC cables. Transceivers must be
purchased separately.
For the available transceivers for the switch, see https://www-01.ibm.com/products/
hardware/configurator/americas/bhui/launchNI.wss.
QSFP+ ports
Four 40 GbE QSFP+ ports are located on the front panel. These ports accept
supported optical QSFP+ transceivers or DACs. The supported transceivers
interoperate with any 40 GBASE-SR4 compliant device, and support distances up
to 100 meters on OM3 fiber. Transceivers must be purchased separately.
QSFP+ ports allow you to make one 40 GbE connection, or four 10 GbE
connections, using a breakout cable, as follows:
v QSFP+ optical transceiver with MTP-to-4 LC (SFP+) fiber breakout cable. This
option supports only IBM 10 GBASE-SR SFP+ transceivers. The 40 GBASE-SR4
specification (802.3ba-2010) indicates a higher optical power level than standard
10 GBASE-SR. IBM SFP+ SR transceivers can handle the higher optical power
levels. This cable must be purchased separately from your fiber cable supplier.
v QSFP+ to four 10 GbE SFP+ breakout DAC. The SFP+ connectors on supported
breakout DACs are labelled A, B, C, and D, which correspond to the first,
second, third, and fourth ports in the port range. This cable must be purchased
separately from your fiber cable supplier.
For the available QSFP+ transceivers and DACs for the switch, see
https://www-01.ibm.com/products/hardware/configurator/americas/bhui/launchNI.wss.
8IBM System Networking RackSwitch G8264CS: Installation Guide
Fibre Channel/Ethernet Omni Ports
Features of Fibre Channel/Ethernet Omni Ports include:
v Each Omni Port is capable of running in 10 Gb Ethernet mode or four to eight
Gb Fibre Channel (FC) mode with auto-negotiation capability.
v Support for NPV (N_Port Virtualization) Gateway provides connectivity to the
Fibre Channel SAN.
v Support for FC-BB-5 Compliant Full Fabric FC/FCoE switch. Fabric Services are
Name Server, Registered State Change Notification (RSCN), Login Services and
Zoning (WWN, FCID or Alias-based Zoning).
Console port
The RS-232 (mini-USB) serial console port is located on the front panel, see
Figure 1 on page 5. The following table describes the pinouts for the mini-USB port.
The RJ-45 (copper) external management port is located on the front panel, see
Figure 1 on page 5. A retention clip is available to secure the console connection.
The following table describes the pin assignments for the RJ-45 connector on the
console cable.
Table 2. RJ-45 connector pin assignments
Pin numberFunction
1RTS (Request To Send)
2DTR (Data Terminal Ready)
3TxD (Transmit Data)
4GND (Ground)
5GND (Ground)
6RxD (Receive Data)
7DSR (Data Set Ready)
8CTS (Clear To Send)
The following items are also included with the console cable.
v Category 5 patch cable
v RJ-45 to female DB9 adapter
To connect a computer or terminal to the switch, first connect the console cable to
the mini-USB port on the front panel. Connect one end of the patch cable to the
RJ-45 port on the console cable, and the other end of the patch cable to the
RJ-45-to-DB9 adapter (see the following illustration).
Chapter 1. Introduction9
Switch LEDs
To
Switch
Switch
Console Cable
Figure 4. Console cable connections
Category 5
Patch Cable
RJ-45 Adapter
To P C
Terminal
USB port
The USB port is located on the front panel, see Figure 1 on page 5. It allows you to
connect a USB drive to the switch. You can copy files from the switch to the USB
drive, or from the USB drive to the switch. You can also start the switch using files
on the USB drive.
For more information about using the USB drive, see the IBM System NetworkingRackSwitch G8264CS Release Notes.
The following illustration shows the switch LEDs.
Figure 5. Switch status LEDs
The switch and port link status LEDs are described in the following table.
Table 3. Switch LEDs
SymbolDescription
!Service LED
Power supplies and power input status
Fan status
SStacking indicator
10IBM System Networking RackSwitch G8264CS: Installation Guide
The switch LEDs are located on the front panel and are described in the following
table.
Table 4. Switch LED descriptions
FunctionMasterMemberPower supplyService
Total Power FailureOffOffOffOff
Service RequiredFlashing blueSee belowSee belowSee below
Power Supplies OKOffSolid greenNot applicableNot applicable
Power Supply Failure Flashing blueFlashing greenNot applicableNot applicable
Fans OKOffNot applicableNot applicableNot applicable
Fan FailureFlashing blueNot applicableFlashing greenNot applicable
RJ-45 LEDs
The RJ-45 LEDs are shown in the following illustration.
RJ-45 port LEDs
Link LED
Status LEDs for the RJ-45 ports are located on the front panel and are described in
the following table.
Activity LED
Table 5. RJ-45 LEDs status
LEDSteady greenFlashing AmberOff
LinkLink upNot applicableNo link
ActivityNot applicableActivityNo activity
SFP+ LEDs
Status LEDs for the SFP+ ports are located on the front panel and are described in
the following table.
Table 6. SFP+ LEDs status
Steady greenFlash greenOff
Link upActivityNo Link
QSPF+ LEDs
The QSFP+ LEDs are shown in the following illustration.
QSFP+
LEDs
Figure 6. QSFP+ LEDs
Chapter 1. Introduction11
Status LEDs for the QSFP+ ports are described in the following table. When the
port is 40 GbE mode, only the first LED applies. When the port is in four 10 GbE
mode, each LED provides status for its corresponding 10 GbE port, as noted in the
following table.
Table 7. QSFP+ LEDs status
Steady
LED
QSFP+ linkValid linkActivityNot
QSFP+
speed
green
10 Gb SFP+Not
Flashing
green
applicable
Solid
Amber
applicable
Not
applicable
Flashing
AmberOff
Not applicable No link
Not applicable 1 Gb SFP
Omni Port LEDs
Status LEDs for the Omni Ports are located on the front panel and are described in
the following table.
Table 8. Omni Port LEDs status
Steady
LED
LinkValid linkActivityNot
Speed10G 4/8 GbNot
ModeThe port pair
green
is configured
for FC mode.
Flashing
greenSolid Amber
applicable
Not
applicable
One or both
of the
installed
devices is not
compatible
with the
mode
configured
(Ethernet/FC)
for the port
pair.
applicable
Not
applicable
Flashing
AmberOff
Not applicable No link
Not applicable Not
applicable
Not applicable The port pair
is configured
for Ethernet
mode.
Technical specifications
The IBM System Networking RackSwitch G8624CS technical specifications are
described in the following sections.
Physical characteristics
The physical characteristics of the System Networking RackSwitch G8264CS are
listed in the following table.
Table 9. Physical characteristics
SpecificationPhysical characteristics
Dimensions (HxWxD)4.45 x 43.9 x 48.26 cm.
Weight10.35 kg. (22.1 lb) (maximum)
AirflowFront-to-rear, rear-to-front
12IBM System Networking RackSwitch G8264CS: Installation Guide
(1.75 x 17.3 x 19 in.)
Environmental specifications
The environmental specifications for the switch are listed in the following table.
Table 10. Environmental specifications
SpecificationMeasurement
Temperature, ambient operating0° C to +40° C (32° F to 104° F) with four
Temperature (fan failure), operating0° C to +35° C ( 32° F to 95° F) with four
Temperature, storage-40° C to +85° C (-40° F to 167° F)
Relative humidity (non-condensing),
operating
Relative humidity (non-condensing), storage10 to 90%
Altitude, operating1,800 m (6,000 ft)
Altitude, storage12,190 m (40,000 feet)
Acoustic noiseLess than 65 dB
Heat dissipation1127 BTU/hour (typical)
Power specifications
The power specifications for the switch are listed in the following table.
fans
fans
10 to 90%
1280 BTU/hour (maximum)
Table 11. AC power specifications
SpecificationMeasurement
Number of power supplies2 (1+1 load sharing/redundant)
AC-input frequency (universal)50/60 Hz
AC-input voltage (universal)100 - 127 VAC
200 - 240 VAC
AC inrush current15 A
AC-input current (typical)2.09 A (RMS) @ 120 V
1.10 A (RMS) @ 230 V
AC-input current (maximum)2.28 A (RMS) @ 120 V 1.30 A (RMS) @ 230
V
Power supply rated output power550 W
750 W
System power dissipation (typical)253 W
System power dissipation (maximum)276 W
DC-output current20.6 A (typical)
Chapter 1. Introduction13
14IBM System Networking RackSwitch G8264CS: Installation Guide
Chapter 2. Installing the RackSwitch and options
This chapter describes the how to install the RackSwitch chassis and the
associated RackSwitch components
v “Installing the RackSwitch in a standard equipment rack” on page 19
v “Installing the RackSwitch in an IBM iDataPlex rack” on page 22
v “Installing the RackSwitch in an IBM System x or Power rack” on page 25
v “Installing the 1U air duct option” on page 28
v “Installing an SFP, SFP+, QSFP+, and Omni Port transceiver” on page 32
Note: When replacing a RackSwitch chassis, all internal components must also be
removed from the chassis and replaced in the new chassis. For more
information on removing and replacing the RackSwitch and components, see
Chapter 3, “Removing and replacing the RackSwitch and components,” on
page 37.
Before installing the RackSwitch
Locate and record the important product information about the switch in the
following table. The identification labels contain the machine-type model (MTM)
number, serial number and part number (front, rear panel and/or bottom of the unit),
and the media access control (MAC) address (rear of unit) for the switch. The MAC
address is not required for opening a service call.
You can also review and record your product serial number and other required
information through the software interface by issuing the show sys-info command
using the ISCLI interface or the /info/sys/general command using the MenuCLI
interface. For more information about these commands, see “Configuring Vital
Product Data after a switch replacement” on page 46.
After the switch is installed most of the identification labels are hidden from view
and require removing the switch in order to relocate them.
Attention:This product information is required to register your product, to update
your firmware, place a service call, and replace the RackSwitch.
Note: The following sample RackSwitch identification (ID) labels may have different