ÉÂÔ Installation Instructions
Installation of
Field Feature Bill of Material (FFBM)
PN 26L0451
Install Network Node Control Point (NNP-B)
Type 3
(Based on 6275)
Feature Code 5423
on IBM 3746-900.
Written by: C. Vallee
Checked by: C. Franoux
Approved by: A. Badino
Reviewed by: R. Lympany
3746 PN 42L2445 EC F52322 EC F12701A EC F70078
FFBM 1 of 10 09 Oct 1998 14 DEC 1998 22 APR 1999
Copyright IBM Corp. 1998, 1999 1
ÉÂÔ Installation Instructions
3746 PN 42L2445 EC F52322 EC F12701A EC F70078
FFBM 2 of 10 09 Oct 1998 14 DEC 1998 22 APR 1999
2
ÉÂÔ Installation Instructions
Before Installation (Steps 1-8)
1.0 Machines Affected
3746 Model 900 with service processor and network node processor type:
6275-56U, 6275-83U, 7585-P02, or 3172-P90.
This feature should only be applied on the machine serial number for which it is
specified
.
2.0 Related BMs and ECs
2.1 Prerequisites
(Must be installed prior to this installation)
Feature Title
5053 Service Processor type 6275-56U or 6275-83U or
5052 Service Processor type 7585-P02 or
5021 Service Processor type 3172-P90
5423 Network Node Processor-A type 6275-56U or 6275-83U or
5122 Network Node Processor-A type 7585-P02 or
5022 Network Node Processor-A type 3172-P90
EC Title
F12720 Licensed Internal Code (Minimum level)
Checkpoint: Check that the APPN EC Level is F12721.000 or higher.
Note: Refer to the
service processor, verify that the code is at EC F12720 or above.
Use the procedure: Displaying the EC Level of the Code installed
on the hard disk. If the EC of the code installed is prior to F12720,
use the installation instructions to install the new level of code shipped.
SPIM
or the
Service User's Guide
shipped with the
3746 PN 42L2445 EC F52322 EC F12701A EC F70078
FFBM 3 of 10 09 Oct 1998 14 DEC 1998 22 APR 1999
3