IBM Netfinity 5Ux24D Tower-to-Rack Kit Installation Instructions Manual

IBM Netfinity 5Ux24D Tower-to-Rack Kit
Installation Instructions
IBM
IBM
IBM Netfinity 5Ux24D Tower-to-Rack Kit
Installation Instructions
Note
Second Edition (April 2000)
The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.
This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other countries, and the information is subject to change without notice. Consult your local IBM representative for information on the products, services, and features available in your area.
Requests for technical information about IBM products should be made to your IBM reseller or IBM marketing representative.
Copyright International Business Machines Corporation 2000. All rights reserved.
Note to U.S. Government Users — Documentation related to restricted rights — Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corp.
Contents
Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
5Ux24D Tower-to-Rack Kit Introduction ................................... 1
Tool requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Preparing the server for rack installation .................................. 3
Installing the server in a rack cabinet .................................... 14
Using the Netfinity 5600 setup utility diskette ............................... 20
Getting help, service, and information .................................... 21
Product warranties and notices ........................................ 22
Warranty Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
IBM Statement of Limited Warranty for United States, Puerto Rico, and Canada (Part 1 - General
Terms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
IBM Statement of Warranty Worldwide except Canada, Puerto Rico, Turkey, United States (Part 1 -
General Terms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Part 2 - Worldwide Country-Unique Terms ................................. 26
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Copyright IBM Corp. 2000 iii
Figures
1. Removing the server door ......................................... 4
2. Removing the left-side cover ........................................ 4
3. Removing the server bezel ......................................... 5
4. Removing the right-side cover ....................................... 5
5. Installing the new bottom cover ...................................... 6
6. Removing the server feet .......................................... 6
7. Moving the power-switch panel ...................................... 7
8. Removing the LED panel .......................................... 7
9. Removing the existing cable from the LED panel assembly ...................... 8
10. Removing the processor board to install the new cable ........................ 8
11. Locating the LED panel cable connector on the system board .................... 9
12. Routing the LED panel cable ........................................ 10
13. Installing the LED panel in the new location ............................... 10
14. Repositioning the non-hot-swap drives .................................. 11
15. Installing the release-latch-bracket assemblies ............................. 12
16. Installing the new bezel ........................................... 12
17. Installing the top cover ........................................... 13
18. Installing the rack-support wheels ..................................... 13
19. Locating cage nuts or clip nuts on the front and rear of a rack cabinet ............... 15
20. Installing the slide rails ........................................... 16
21. Assembling and installing the cable-management arms ........................ 16
22. Placing the server on the slide rails .................................... 17
23. Securing the server to the rails ...................................... 18
24. Routing server cables ............................................ 18
25. Securing the server inside the rack .................................... 19
iv Copyright IBM Corp. 2000

Safety information

Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Avant d'installer ce produit, lisez les consignes de sécurité.
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
Pred inštaláciou tohto zariadenia si pečítaje Bezpečnostné predpisy.
Antes de instalar este producto lea la información de seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
Copyright IBM Corp. 2000 v
vi 5Ux24D Tower-to-Rack Kit Installation Instructions

5Ux24D Tower-to-Rack Kit Introduction

The IBM Netfinity 5Ux24D Tower-to-Rack Kit converts a 5U server that is 61.0 cm (24 in.) deep from a tower model to a rack model. You can then install the server into a rack cabinet that is at least 61.0 cm (24 in.) deep.
The following parts come with the 5Ux24D Tower-to-Rack Kit:
Two release-latch-bracket assemblies (one left and one right)
Two server covers
One rack-model trim bezel
Two rack-support wheels
Two slide rails
One cable-management arm (comes partially assembled):
Two rigid cable-management arms
One flexible cable-management arm
One hinge bracket
Four hinge pins
One LED panel cable (required for some servers)
Cable straps
Miscellaneous hardware kit (includes screws, cage nuts, and clip nuts to install the server in a rack
cabinet)
IBM Safety Information booklet
One rack installation template
One or more system-specific service labels
One IBM Netfinity 5600 Hot-Plug SCSI Setup Utility diskette
This documentation
Note: The illustrations in this documentation might be slightly different from your hardware.

Tool requirements

You will need the following tools to install the 5Ux24D Tower-to-Rack Kit:
A small flat-blade screwdriver
A medium phillips screwdriver
An 8-mm open-end or box wrench
A 10-mm nut driver or a 10-mm open-end or box wrench
Copyright IBM Corp. 2000 1

Installation overview

Use the following general steps to prepare your server and install the 5Ux24D Tower-to-Rack Kit:
1 Follow the instructions in Preparing the server for rack installation on page 3 to prepare your
server.
2 Follow the instructions in Installing the server in a rack cabinet on page 14 to install your server.
3 Attach all cables and neatly route them before turning on your server.
2 5Ux24D Tower-to-Rack Kit Installation Instructions

Preparing the server for rack installation

Use the following steps to prepare your server for rack installation:
1. Refer to your server documentation for detailed information.
2. Shut down the server operating system and remove all media from the drives, such as diskettes, CDs,
optical disks, or tapes.
1
DANGER
Electrical current from power, telephone, and communication cables is hazardous.
To avoid a shock hazard:
– Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
Connect all power cords to a properly wired and grounded electrical outlet.
Connect to properly wired outlets any equipment that will be attached to this
product.
When possible, use one hand only to connect or disconnect signal cables.
Never turn on any equipment when there is evidence of fire, water, or
structural damage.
– Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.
– Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached devices.
To Connect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
5. Turn device ON.
To Disconnect:
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
Copyright IBM Corp. 2000 3
3. Turn Off the server and any attached devices.
4. Disconnect all power cords from the server and electrical outlets.
5. Disconnect all communication cables from external devices that are connected to your server.
6. Note the location of any remaining cables; then, disconnect all other cables from the server.
7. Unlock the server door and press down on the flange at the top edge of the door; then, swing the door
forward and lift it away from the server and store the door for potential future use.
C P
U V R
M M
E M
O
P
H
R
C
D
Y
I
D
B
U S
A
B
N M
P
I O W
S M
E
R
I
S
U
S
P
E
1
P
R
L
V
BU
Y
IC
2
S
E
P
3
R O
C E
FA
S
N
S
N
O
O
N
R
R
E D
U
N
1
D A
2
N
T
3
T
E
M
P E
R
A T
U
R E
Figure 1. Removing the server door
8. Remove the left-side cover as shown below:
a. Locate the release lever A on the front of the server and slide it to the right.
B
A
Figure 2. Removing the left-side cover
b. Slide the left-side cover towards the back of the server about 25 mm (1 in.); then, lift the cover
away from the server.
Note: Save the cover to refer to the system service label on the inside of the cover.
4 5Ux24D Tower-to-Rack Kit Installation Instructions
Loading...
+ 26 hidden pages