IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide v
Page 8
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide vi
Page 9
Chapter 1. IBM Flex System FC5054 4-port 16
Gb FC Adapter
The IBM Flex System FC5054 4-Port 16 Gb FC Adapter enables the installation of four
™
16 Gb ports of high-speed Fibre Channel in IBM Power Systems
X-Architecture® compute nodes.
These ports interface to chassis switches or pass thru modules, enabling connections
within and/or external to the chassis. IBM Flex System switches with 42 internal ports
support up to 6 ports on this adapter. The firmware and drivers for Linux, Windows,
and VMware for this four-port adapter are provided by Emulex, while the AIX driver
and AIX tool support (for IBM Power Systems) are provided by IBM.
This User's Guide contains information and instructions for functionally installing the
adapter, updating the firmware, and solving problems. See the documentation that
came with the IBM Flex System compute node for information on how to physically
install the adapter; then, return to this User's Guide for information and instructions
needed to complete the functional installation.
For information about the types of compatible devices available for IBM products,
contact your IBM marketing representative or authorized reseller. For a list of
supported optional devices, see
http://www.ibm.com/servers/eserver/serverproven/compat/us/.
and IBM
Related documentation
This User's Guide contains setup and installation instructions for the adapter and
general information about the adapter, including how to configure, update, and
troubleshoot the adapter, and how to get help.
In addition to this document, the following documentation is available:
IBM Flex System compute node User's Guides
These documents contain the hardware installation instructions for the adapter.
IBM Flex System Enterprise Chassis Installation and Service Guide
This document contains information about setting up, configuring, and
troubleshooting the IBM Flex System Enterprise Chassis and its components.
IBM Flex System Chassis Management Module Command-Line Interface Reference
Guide
This document explains how to use the Chassis Management Module
command-line interface (CLI) to directly access management functions. The
command-line interface also provides access to the text-console command
prompt on each compute node through a Serial over LAN (SOL) connection.
IBM Flex System Chassis Management Module User's Guide
This document explains how to use the Chassis Management Module user
interface to manage chassis components.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 1
Page 10
IBM Flex System Manager System Management Guide
Notices for Network Device
This document explains how to use the IBM Flex System Manager user interface
to manage chassis components.
Environmental Notices and User Guide
This document is provided on the IBM Notices for Network Devices CD, and it
contains translated environmental notices.
Safety Information
This document is provided on the IBM Notices for Network Devices CD, and it
contains translated caution and danger statements. Each caution and danger
statement that appears in the documentation has a number that you can use to
locate the corresponding statement in your language in the Safety Information
document.
Warranty Information
This document comes with the adapter and contains information about the
terms of the warranty.
For the most up-to-date product documentation for all of your IBM Flex System
products, go to the IBM Flex System Information Center at
http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp.
Notices and statements in this document
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 2
Page 11
Features and specifications
The IBM Flex System FC5054 4-Port 16 Gb FC adapter has the following features and
specifications:
Four independent 16 Gb Fibre Channel ports (IBM Flex System switches with 42
internal ports support up to 6 ports on this adapter)
4 Gb, 8 Gb, or 16 Gb FC link speeds (auto-negotiated)
Two independent x1 to x8 PCIe interfaces at 2.5 GT/s, 5 GT/s, or 8 GT/s
(auto-negotiated with system)
ECC protection of high-density RAM (single-bit correction, double-bit
detection)
KR protocol support at 16 Gb
Voltage specifications are 3.3 VAux and 12 V from the adapter connector
Standard IBM size adapter form factor (84.8 mm x 96.7 mm)
Non-volatile memory consisting of two sets of 256 Mbit Program Flash and 256
Kbit error log EEPROM, and a shared 512 Kbit VPD EEPROM,
Parts and construction compliant to the European Union Directive of Restriction
of Hazardous Substances (RoHS), and similar regulatory requirements for other
countries.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 3
Page 12
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 4
Page 13
Chapter 2. Installing the adapter
This chapter provides information and instructions for installing and configuring the
adapter. See the documentation that came with the IBM compute node to install the
adapter in the compute node; then, return to this User's Guide for the information and
instructions needed to complete the installation.
Installing device drivers
For device driver installation instructions, refer to the following operating
system-specific instructions or documentation.
AIX device driver software
Note: This section applies only to IBM Power Systems compute nodes.
This adapter device driver is included in the following AIX releases or later. Refer to
the installation instructions for the specific AIX release to install or update the driver
software.
AIX V7.1.B with the 7100-07 Technology Level and Service Pack 6, or later
AIX V7.1 with the 7100-01 Technology Level AP
AIX 7.1 with the 7100-02 Technology Level
AIX V6.1 with the 6100-08 Technology Level
AIX 6.1.N with the 6100-07 Technology Level and Service Pack 6, or later
AIX 5.3
Note: Assignment to the VIOS requires VIOS 2.2.1.6, 2.2.2.0, or later.
IBM i 7.1 with i 7.1.0 machine code: RS710-10 OS and (RS710-F LIC or
Technology Refresh 3 (TR PTF Group SF99707 Level 3)) and Cumulative
Package 7.1 C2279710, or later
IBM i 6.1 with i 6.1.1 machine code - i 6.1.1: RS610-10 OS and RS611-J LIC and
Cumulative Package C2305610, or later
Linux device driver software
This adapter is supported in the following Linux distributions or later versions.
Red Hat Enterprise Linux 6.1 (PPC-64)
Red Hat Enterprise Linux 6 (x86-64) – both KVM support and no KVM
Red Hat Enterprise Linux 6 (Server) 64-bit with KVM support
Red Hat Enterprise Linux 5.6 (PPC-64)
Red Hat Enterprise Linux 5 (x86-64)
Red Hat Enterprise Linux 5 – Xen kernels (x86-64)
Red Hat Enterprise Linux 5 (Server) 64-bit
Red Hat Enterprise Linux 5 (Server) – Xen kernel (64-bit)
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 5
Page 14
SUSE Linux Enterprise Server 11 (x86-64) with Service Packs 1 and 2 only
SUSE Linux Enterprise Server 11 – Xen kernels (x86-64) with Service Packs 1
and 2 only
SUSE Linux Enterprise Server 11 (PPC-64)
SUSE Linux Enterprise Point of Service 11 (SLEP OS)
SUSE Linux Enterprise Server 10 (x86-64) with Service Packs 3 and 4 only
SUSE Linux Enterprise Server 10 – Xen kernels (x86-64) with Service Packs 3
and 4 only
SUSE Linux Enterprise Server 10 with Service Pack 4 (PPC-64)
For IBM Power Systems compute nodes, refer to the installation instructions for your
specific Linux distribution to install driver software.
For IBM X-Architecture compute nodes, refer to the installation instructions available at
http://www.emulex.com/downloads/ibm.html.
VMware device driver software
Note: This section applies only to IBM X-Architecture compute nodes.
This adapter is supported in the following VMware versions.
ESX 4.1 or later
ESXi 4.1, 4.1.1, and 4.1.2
ESXi 5.0
ESXi 5.1
Refer to the installation instructions available at
http://www.emulex.com/downloads/ibm.html.
Windows device driver software
Note: This section applies only to IBM X-Architecture compute nodes.
This adapter is supported in the following Window versions.
Windows Server 2008 (Datacenter/Enterprise/Standard/Web) 64-bit only
Windows Server 2008 R2 (x86-64 only)
Windows Server 2008 HPC Edition 2008 (x86-64 only)
Windows Server 2008 Small Business Premium/Standard Edition (x86-64 only)
Windows Server 2012 (x86-64 only)
Refer to the installation instructions available at
http://www.emulex.com/downloads/ibm.html.
Other device driver software
This adapter is supported with the IBM 4690 Operating System. Refer to the installation
instructions for your specific operating system to install the driver software.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 6
Page 15
Managing the adapter
For IBM Power Systems compute nodes, refer to the documentation for your specific
operating system regarding management of the adapter's features and functions.
For IBM X-Architecture compute nodes, the adapter management information is
provided in the following application and utilities documentation:
OneCommand™ Manager Application User Manual
Offline and Online Adapter Management Utilities User Manual
Boot from SAN information is available in the Boot for Fibre Channel Protocol User
Manual.
The documentation is available at http://www.emulex.com/downloads/ibm.html.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 7
Page 16
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 8
Page 17
Chapter 3. Updating the firmware
This chapter contains information and instructions for updating the adapter firmware.
Important:Installing the wrong firmware or device-driver update might cause the
network adapter or switch to malfunction. Before you install a firmware
or device-driver update, read any readme and change history files that are
provided with the downloaded update. These files contain important
information about the update and the procedure for installing the update,
including any special procedure for updating from an early firmware or
device-driver version to the latest version.
Determining the adapter firmware level and
upgrading adapter firmware
AIX
Note: This section applies only to IBM Power Systems compute nodes.
Diagnostics are used to determine the adapter firmware level and to upgrade the
adapter firmware. AIX systems can use either stand-alone diagnostics or AIX
concurrent diagnostic utilities. Systems running other operating systems have the
option to run the AIX stand-alone diagnostics or utilities provided for the specific
operating system.
The AIX-based stand-alone diagnostics are available from the IBM website. Boot the
diagnostics from a CD drive or from an AIX NIM server if the compute node cannot
boot to an operating system, no matter which operating system is installed. Run AIX
concurrent diagnostics if AIX is functioning instead of the stand-alone diagnostics.
Refer to your system's documentation on running the diagnostic program.
Linux
For IBM Power Systems compute nodes, refer to the instructions on using the ethtool -f
command in the operating system documentation for your specific Linux distribution
for information on how to determine the adapter firmware level and upgrade the
firmware.
For IBM X-Architecture compute nodes, refer to the following application and utilities
documentation for information on determining the adapter firmware level and
upgrading the adapter firmware.
OneCommand™ Manager Application User Manual
Offline and Online Adapter Management Utilities User Manual
The documentation is available at http://www.emulex.com/downloads/ibm.html.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 9
Page 18
VMware
Note: This section applies only to IBM X-Architecture compute nodes.
Refer to the following application and utilities documentation for information on
determining the adapter firmware level and upgrading the adapter firmware.
OneCommand™ Manager Application User Manual
Offline and Online Adapter Management Utilities User Manual
The documentation is available at http://www.emulex.com/downloads/ibm.html.
Windows
Note: This section applies only to IBM X-Architecture compute nodes.
Refer to the following application and utilities documentation for information on
determining the adapter firmware level and upgrading the adapter firmware.
OneCommand™ Manager Application User Manual
Offline and Online Adapter Management Utilities User Manual
The documentation is available at http://www.emulex.com/downloads/ibm.html.
Obtaining the latest level of adapter firmware
For IBM Power Systems compute nodes, the latest level of IBM-supported adapter
firmware can be downloaded from the IBM website. Go to Support and Downloads
and follow the menu selections to locate the specific adapter firmware.
For IBM X-Architecture compute nodes, refer to the following application and utilities
documentation for information on upgrading the adapter firmware:
OneCommand™ Manager Application User Manual
Offline and Online Adapter Management Utilities User Manual
The documentation is available at http://www.emulex.com/downloads/ibm.html.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 10
Page 19
Chapter 4. Solving problems
If you cannot locate and correct a problem by using the information in this section, see
Appendix A, “Getting help and technical assistance,” on page 13.
Running POST
To ensure that it is fully operational, the adapter processes a series of tests during
power-up or a restart (power-on self-test, or POST). These tests take approximately 1
minute to complete. The management module reads the test results and displays them
for you. During normal operation, these tests are completed without error, and the
green OK LED is lit. However, if the adapter fails POST, the amber adapter error LED
and the system-error LED on the chassis are lit.
Parts listing
Replaceable components are of three types:
Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your
responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged
for the installation.
Tier 2 customer replaceable unit (CRU): You may install a Tier 2 CRU yourself
or request IBM to install it, at no additional charge, under the type of warranty
service that is designated for your server.
Field replaceable unit (FRU): FRUs must be installed only by trained service
technicians.
For information about the terms of the warranty, see the Warranty Information
document.
The replaceable components in the following table are Tier 1 CRUs. If other
components require replacement, see the documentation that came with those devices
for instructions.
PartCRU number (Tier 1)
IBM Flex System FC5054 4-Port 16 Gb FC Adapter95Y2394
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 11
Page 20
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 12
Page 21
Appendix A. Getting help and technical
assistance
Before you call
Using the documentation
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 13
Page 22
Getting help and information from the World Wide
Web
Software service and support
Hardware service and support
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 14
Page 23
IBM Taiwan product service
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 15
Page 24
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 16
Page 25
Appendix B. Notices
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 17
Page 26
Trademarks
IBM, the IBM logo, and ibm.com are trademarks of International
Business Machines Corp., registered in many jurisdictions worldwide.
Other product and service names might be trademarks of IBM or other
companies. A current list of IBM trademarks is available on the web at
"Copyright and trademark information"
at http://www.ibm.com/legal/copytrade.shtml
Adobe and PostScript are either registered trademarks or trademarks of
Adobe Systems Incorporated in the United States and/or other countries.
Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc., in the
United States, other countries, or both and is used under license
therefrom.
Intel, Intel Xeon, Itanium, and Pentium are trademarks
or registered trademarks of Intel Corporation or its subsidiaries
in the United States and other countries.
Java and all Java-based trademarks and logos are trademarks or registered
trademarks of Oracle and/or its affiliates.
Linux is a registered trademark of Linus
Torvalds in the United States, other countries, or both.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in
the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other countries.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 18
Page 27
Important notes
This product is not intended to be connected directly or indirectly by any means
whatsoever to interfaces of public telecommunications networks, nor is it intended
to be used in a public services network.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 19
Page 28
Electronic emission notices
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 20
Page 29
IBM Deutschland GmbH
IBM Technical Regulations, Department M372
IBM-Allee 1,71139 Ehningen, Germany
Telephone: +49 7032 15 2941
Email: lugi@de.ibm.com
European Community contact:
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 21
Page 30
GmbH
Abteilung M372
39
41
lugi
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 22
Page 31
This is electromagnetic wave compatibility equipment
for business (Type A). Sellers and users need to pay
attention to it. This is for any areas other than home.
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 23
Page 32
IBM Flex System FC5054 4-Port 16 Gb FC Adapter User's Guide 24
Page 33
Page 34
IBM Part Number: 00D2351
Emulex Part Number: P009539-01A Rev. A