IBM xSeries 345, eServer xSeries 345 8670 Installation Manual

Page 1
Install options:
• Drives
• Microprocessors
• Adapters
• Memory
xSeries 345
Type 8670
Installation Guide
Welcome. . .
Thank you for buying an IBM xSeries server. is based on the X-Architecture technology, and it features superior performance, availability, and scalability.
This server
Installation Guide
contains information for setting up and configuring your server.
Your server
Install the server in
the rack, if required
Cable the server
and options
Start the server
Did the server start correctly?
Yes
Use ServerGuide™
to set up and
configure hardware
No
Go to the Server Support
flow chart
For detailed information about your server, view the publications on the
Documentation CD.
You can also find the most current information about your server on the IBM Web site at: http://www.ibm.com/pc/support
Did configuration
complete?
Yes
Use
ServerGuide to
install operating
system?
Yes
Install applications, such as IBM systems management software and IBM ServeRAID programs
System is ready to use.
Go to the Server Support
flow chart to register
and profile your server.
No
No
Go to the Web for instructions,
http://www.ibm.com/pc/support
Page 2
Server Support
Server working
properly?
Yes
No
Check all cables for loose connections and verify that all optional devices you installed are on the ServerProven list. You can view the ServerProven list at
http://www.ibm.com/pc/compat/
Problem
solved?
®
Yes
No
Use the troubleshooting information provided with your server to determine the cause of the problem and the action to take.
Register and profile your server
After you register and profile, you will be able to:
• Diagnose problems using the IBM Online Assistant
• Participate in the IBM discussion forum
• Receive e-mail notifications of technical updates related to your profiled products
Register: Profile:
http://www.ibm.com/pc/register/
http://www.ibm.com/pc/support/
View information about IBM support line at
http://www.ibm.com/services/sl/products/
or view support telephone numbers at
http://www.ibm.com/planetwide/
View support telephone numbers at
http://www.ibm.com/planetwide/
Problem
solved?
Yes
No
Flash the latest levels of BIOS, service processor, diagnostics, and RAID code. You can download this code at
http://www.ibm.com/pc/support/
Yes Hardware
Problem
solved?
No Software
Hardware or
software problem?
Page 3
IBM xSeries 345 Type 8670
Installation Guide
򔻐򗗠򙳰
SC48-P971-40
Page 4
Note:
Before using this information and the product it supports, be sure to read the general information in Appendix A, “Warranty information” on page 37, and Appendix B, “Notices” on page 49.
Second Edition (July 2002) © Copyright International Business Machines Corporation 2002. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Page 5
Contents
Safety ............................v
Chapter 1. Introduction......................1
Features and specifications.....................2
Notices and statements in this book .................3
Major components of your server ..................4
Chapter 2. Installing options....................5
Installation guidelines .......................5
System reliability considerations ..................5
Working inside the server with the power on .............5
Handling static-sensitive devices ..................5
Installing adapters ........................6
Installing memory modules .....................9
Installing a hot-swap drive .....................11
Installing an additional microprocessor ................12
Installing a hot-swap power-supply option ...............16
Completing the installation.....................17
Chapter 3. Server power, controls, and indicators ...........19
Front view ..........................19
Rear view ...........................20
Server power features ......................21
Turning on the server .....................21
Turning off the server .....................22
Standby mode ........................22
Chapter 4. Configuring your server ................23
Using the ServerGuide Setup and Installation CD ............23
Using the Configuration/Setup Utility program .............24
Using ServeRAID Manager ....................24
Using the LSI Logic Configuration Utility program ............25
Chapter 5. Solving problems ...................27
Diagnostic tools overview .....................27
POST beep code descriptions ...................27
POST error messages ......................28
ServerGuide problems ......................29
Troubleshooting chart ......................30
Chapter 6. Getting help and technical assistance ...........35
Before you call .........................35
Using the documentation .....................35
Getting help and information from the World Wide Web ..........35
Software service and support ...................36
Hardware service and support ...................36
Appendix A. Warranty information .................37
Warranty period ........................37
Problem determination .....................37
Warranty service and support ..................38
International Warranty Service ..................39
Purchasing additional services ..................39
© Copyright IBM Corp. 2002 iii
Page 6
IBM Statement of Limited Warranty Z125-4753-06 8/2000 .........40
Part 1 - General Terms .....................40
Part 2 - Country-unique Terms ..................42
Appendix B. Notices ......................49
Edition notice .........................49
Trademarks ..........................50
Important notes.........................50
Electronic emission notices ....................51
Federal Communications Commission (FCC) statement .........51
Industry Canada Class A emission compliance statement ........52
Australia and New Zealand Class A statement ............52
United Kingdom telecommunications safety requirement.........52
European Union EMC Directive conformance statement .........52
Taiwan electrical emission statement ................52
Japanese Voluntary Control Council for Interference (VCCI) statement . . . 53
Power cords ..........................53
Index ............................55
iv IBM xSeries 345 Type 8670: Installation Guide
Page 7
Safety
Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant dinstaller ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
© Copyright IBM Corp. 2002 v
Page 8
Antes de instalar este producto lea la información de seguridad. Lässäkerhetsinformationen innan du installerar den här produkten.
vi IBM xSeries 345 Type 8670: Installation Guide
Page 9
Statement 1
Danger Electrical current from power, telephone, and communication cables is hazardous.
To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or
reconfiguration of this product during an electrical storm.
v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this
product.
v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural
damage.
v Disconnect the attached power cords, telecommunications systems, networks, and
modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following table when installing,
moving, or opening covers on this product or attached devices.
To connect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
To disconnect:
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
5. Turn device ON.
Statement 2
CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water. v Heat to more than 100° C (212° F) v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Safety vii
Page 10
Statement 3
CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could result in
exposure to hazardous laser radiation. There are no serviceable parts inside the device.
v Use of controls or adjustments or performance of procedures other than those
specified herein might result in hazardous radiation exposure.
Danger
Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following. Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
Statement 4
18 kg (39.7 lb) 32 kg (70.5 lb) 55 kg (121.2 lb)
CAUTION: Use safe practices when lifting.
Statement 5
CAUTION: The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2 1
viii IBM xSeries 345 Type 8670: Installation Guide
Page 11
Statement 8
CAUTION: Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.
Statement 12:
CAUTION: The following label indicates a hot surface nearby.
Statement 13
DANGER: Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed the branch circuit protection requirements. Refer to the information that is provided with your IBM device for electrical specifications.
Statement 14
CAUTION: Hazardous voltage, current, and energy levels might be present. Only a qualified service technician is authorized to remove the covers where the following label is attached.
Safety ix
Page 12
Statement 15
CAUTION: Make sure that the rack is secured properly to avoid tipping when the server unit is extended.
Statement 16
CAUTION: Some accessory or option board outputs exceed Class 2 or limited power source limits and must be installed with appropriate interconnecting cabling in accordance with the national electric code.
Statement 17
CAUTION: The following label indicates moving parts nearby.
x IBM xSeries 345 Type 8670: Installation Guide
Page 13
Chapter 1. Introduction
Thank you for purchasing an IBM server is based on the IBM X-Architecture
®
Eserver xSeries™ 345 Type 8670 server. Your
technologies1.
This Installation Guide provides the information that is needed to:
v Set up and cable your server v Start and configure your server v Install options v Install your operating system v Perform basic troubleshooting of your server
Packaged with this Installation Guide are software CDs that help you configure hardware, install device drivers, and install the operating system.
Also included is an IBM xSeries Documentation CD that provides detailed information about this server.
See the Rack Installation Instructions that come with your server for complete rack installation and removal instructions.
Record your product information in this table.
Product name _________________________________________ Machine type _________________________________________ Model number _________________________________________ Serial number _________________________________________
Your server serial number and model number are located on labels on the bottom of the server and on the lower corner of the bezel. You will need these numbers when you register your server with IBM. The information label containing the serial number, machine type, model number, and agency marks for your server is located on the bottom of the server.
1. X-Architecture technology takes full advantage of existing IBM technologies to build powerful, scalable, and reliable Intel processor-based servers. For more information about IBM X-Architecture, go to http://www.ibm.com/pc/us/eserver/xseries/xarchitecture/enterprise/index.html.
© Copyright IBM Corp. 2002
1
Page 14
Features and specifications
The following table provides a summary of the features and specifications for your server.
Table 1. Features and specifications
Microprocessor:
®
v Intel
v 512 KB (minimum) Level-2 cache v 100 MHz front-side bus (FSB), at four
v Support for up to two
Memory:
v Minimum: 512 MB, expandable to 4
v Type: 100 MHz, PC2100 (CL2.5),
v Sizes: 256 MB, 512 MB, or 1 GB, in
v Connectors: Two-way interleaved,
v Maximum: Two pairs of DIMMs
Drives standard:
v Diskette: 1.44 MB v CD-ROM: IDE
Expansion bays:
v Six hot-swap, slim-high, 3.5-inch
v One 5.25-inch bay (CD-ROM drive
v One 3.5-inch removable-media drive
Upgradeable microcode:
BIOS, diagnostics, and IBM Advanced System Management upgrades (when available) can update EEPROMs on the system board
Hot-swap fans:
v Minimum: Five v Maximum: Eight - provide redundant
Hot-swap power supplies:
350 watts (115-230 V ac)
v Minimum: One v Maximum: Two - provide redundant
Xeon™, 2.0 GHz or higher
depending on server model
data transfers per cycle, yielding a 400 MHz system bus
microprocessors with Intel Hyper-Threading technology
GB
downward compatible with PC1600 (CL2), registered, ECC, double data rate (DDR), SDRAM
pairs
four dual inline memory module (DIMM) connectors
drive bays (hot-swap hard disk drives installed, some models)
installed)
bay (diskette drive installed)
cooling
power
PCI expansion slots:
v Two PCI-X non-hot-plug 133 MHz/64-bit v Two PCI-X non-hot-plug 100 MHz/64-bit
(low profile)
v One PCI non-hot-plug, 33 MHz/32-bit
Integrated functions:
v IBM integrated system management
processor (ISMP) – Service processor with Light Path
Diagnostics
Interconnect portDedicated I/O portSupport for IBM Remote Supervisor
Adapter
v Two 10BASE-T/100BASE-
TX/1000BASE-T Ethernet ports (Intel Ethernet controller on system board)
v One serial port v One external and one internal Ultra320
SCSI port (dual-channel integrated controller with RAID capabilities)
v Three Universal Serial Bus (USB) v1.1
ports
v Keyboard port v Mouse port v ATI Rage XL video (controller on
system board)
Compatible with SVGA and VGA8 MB video memory
Acoustical noise emissions:
v Declared sound power, idle: 6.5 bel v Declared sound power, operating: 6.5
bel
v Bystander sound pressure, idle: 48 dBa v Bystander sound pressure, operating:
48 dBa
Environment:
v Air temperature:
Maximum altitude: 2133 m (7000 ft)
Server on: 10° to 35°C(50° to 95°F)Serveroff:-40° to +60°C (-40° to
140°F)
v Humidity:
Server on: 8% to 80%Serveroff:8%to80%
Security features:
v Power-on password v Remote control security settings v Selectable drive startup v Keyboard password v System management security
User login password
Read-only or read/write accessDial-in call-back
Predictive Failure Analysis®(PFA) alerts:
v Power supplies v Fans v Memory v Hard disk drives v Microprocessors v Voltage regulator modules (VRMs)
Size (2 U):
v Height: 85.4 mm (3.36 in.) v Depth: 698 mm (27.48 in.) v Width: 443.6 mm (17.5 in.) v Weight: 21.09 kg (46.5 lb) to 28.12 kg (62
lb) depending upon configuration
Heat output:
Approximate heat output in British thermal units (Btu) per hour v Minimum configuration: 341 Btu/hour (100
watts)
v Maximum configuration: 2200 Btu/hour
(645.2 watts)
Electrical input:
v Sine-wave input (50-60 Hz) required v Input voltage range automatically selected v Input voltage low range:
Minimum: 90 V acMaximum: 137 V ac
v Input voltage high range:
Minimum: 180 V acMaximum: 265 V ac
v Input kilovolt-amperes (kVA) approximately:
Minimum: 0.1 kVAMaximum: 0.62 kVA
Power available for drives:
v +5Vdc v +12Vdc
2 IBM xSeries 345 Type 8670: Installation Guide
Page 15
Notices and statements in this book
The caution and danger statements used in this book also appear in the multilingual Safety Information book provided on the IBM xSeries Documentation CD. Each caution and danger statement is numbered for easy reference to the corresponding statements in the safety book.
The following types of notices and statements are used in this book:
v Note: These notices provide important tips, guidance, or advice. v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate possible damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which damage could occur.
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially hazardous procedure step or situation.
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation.
Chapter 1. Introduction 3
Page 16
Major components of your server
The orange color on components and labels in your server identifies hot-swap or hot-plug components. You can install or remove hot-swap and hot-plug components while the system is running, provided that your system is configured to support this function. For complete details about installing or removing a hot-swap or hot-plug component, see the detailed information in the next chapter.
The blue color on components and labels indicates touch points where a component can be gripped, a latch moved, and so on.
The following illustration shows the major components in the server. Note: The illustrations in this document might differ slightly from your hardware.
PCI riser card assembly
Air baffle
Microprocessor air baffle
Heat sink
Microprocessor
Memory module
Hot-swap fan
Filler panel for drive bay
2
V
VRM
R
M N
NON
O R
REDUNDANT
N E D
U
OV
OVER SPEC
N D
E
A
R
N N
NMI
S
T
M
P
I
E
C
SPSP
C
CPU/VRM
P
MISMATCH
M
U
I
/
S
V
M
R
A
M
T
C
H
A
B
P
PCI
C
BUS
BU
I
C
S
Power supply blank (some models)
1 P
POWER
O S
SUPPLIES
W
U
E
P
R
P
L
Light Path
L
i
g D
Diagnostics
I E
h
i
S
a
t
g
P
n
a
o
t
h s t i c
s
C
CPU
P
U M
MEMORY
E
M
O DA
DASD
R
Y
S
D
R
REMIND
E
M I
N D
FANFAN
T
TEMP
E
M
P
System board
VRM
Hot-swap power supply
Shuttle
4 IBM xSeries 345 Type 8670: Installation Guide
Page 17
Chapter 2. Installing options
This chapter provides the basic information needed to install options in your server. This section is for all users, but it is written with the experienced user in mind. If you need more detailed installation information, see the Option Installation Guide on the IBM xSeries Documentation CD.
Installation guidelines
Be sure to review the information in this section before you begin.
System reliability considerations
Before you begin to install options in your server, read the following information:
v Become familiar with the information provided in “Safetyon page v and
Handling static-sensitive devices. These guidelines will help you work safely
while working with your server options.
v Make sure that you have an adequate number of properly grounded electrical
outlets for your server, monitor, and any other options that you intend to install.
v Back up all important data before you make changes to hard disk drives. v For a list of supported options for your server, go to
http://www.ibm.com/pc/compat/ on the World Wide Web.
v To maintain proper system cooling, do not operate the server for more than 10
minutes without either a drive or a filler panel installed in each bay.
v During normal operation, each power-supply bay must have either a power
supply or power-supply blank installed for proper cooling.
v Do not leave open spaces above or below an installed server in your rack
cabinet. To help prevent damage to server components, always install a blank filler panel to cover the open space and to help ensure proper air circulation. See the documentation that comes with your rack cabinet for more information.
Working inside the server with the power on
Your server supports hot-plug, hot-add, and hot-swap devices and is designed to operate safely while turned on with the cover removed. Follow these guidelines when you work inside a server that is turned on:
v Avoid loose-fitting clothing on your forearms. Button long-sleeved shirts before
working inside the server; do not wear cuff links while you are working inside the server.
v Do not allow your necktie or scarf to hang inside the server. v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist
watches.
v Remove items from your shirt pocket (such as pens or pencils) that could fall into
the server as you lean over it.
v Avoid dropping any metallic objects, such as paper clips, hair pins, or screws,
into the server.
Handling static-sensitive devices
Attention: Static electricity can damage electronic devices and your system. To
avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them.
© Copyright IBM Corp. 2002 5
Page 18
To reduce the possibility of electrostatic discharge, observe the following precautions:
v Limit your movement. Movement can cause static electricity to build up around
you.
v Handle the device carefully, holding it by its edges or its frame. v Do not touch solder joints, pins, or exposed printed circuitry. v Do not leave the device where others can handle and possibly damage the
device.
v While the device is still in its static-protective package, touch it to an unpainted
metal part of the system unit for at least two seconds. (This drains static electricity from the package and from your body.)
v Remove the device from its package and install it directly into your system unit
without setting it down. If it is necessary to set the device down, place it in its static-protective package. Do not place the device on your system unit cover or on a metal table.
v Take additional care when handling devices during cold weather because heating
reduces indoor humidity and increases static electricity.
Installing adapters
This section describes how to install PCI or PCI-X adapters. Before you continue with the adapter-installation procedure, review the following:
v To ensure system reliability, an optional SCSI adapter cannot control internal
hard disk drives.
v You can install only low-profile adapters in slots 1 and 2. v You can install standard full-length adapters, with the adapter guides removed
from the adapters, in slots 3 and 4.
v You can install only a half-length adapter in slot 5. v The optional IBM Remote Supervisor Adapter can be installed only in PCI slot 5.
Use the ribbon cable that comes with the adapter to connect the adapter to the system management connector on the PCI riser card.
v Your server supports 5.0 V and universal PCI adapters in the 32-bit PCI slot 5;
your server supports only 3.3 V and universal PCI adapters in the 64-bit PCI/PCI-X slots 3 and 4.
v The PCI bus configuration is:
Non-hot-plug, 64-bit PCI-X slots 1 through 2 (PCI bus A, 100 MHz)Non-hot-plug, 64-bit PCI-X slots 3 through 4 (PCI bus B, 133 MHz)Non-hot-plug, 32-bit PCI slot 5 (PCI bus C, 33 MHz)
v The system scans PCI and PCI-X slots 1 through 5 to assign system resources;
then, the system starts (boots) the system devices in the following order, if you have not changed the default boot precedence: integrated Ethernet controller, integrated SCSI controller, and then PCI and PCI-X slots 5, 3, 4, 1, and 2.
Note: If you are installing the optional ServeRAID-5i controller, please review the
following: v No rerouting of the internal SCSI cable is required if you are installing the
ServeRAID-5i controller. The ServeRAID-5i controller uses the SCSI connector on the system board for output.
v The ServeRAID-5i controller can be installed only in PCI slot 2. v The low-profile 2-U bracket that comes with the controller is required to
install the controller.
6 IBM xSeries 345 Type 8670: Installation Guide
Page 19
v If the ServeRAID-5i controller is installed, it takes control of the integrated
SCSI controller with RAID capabilities and operates at 66 MHz.
This section contains the procedure for installing an adapter. For more detailed instructions, see the Option Installation Guide on the xSeries Documentation CD.
The following illustrations show the location of the PCI and PCI-X adapter expansion slots on the system board and PCI riser card.
System board
DIMM 2 (J2)
PCI-X slot 1 64-bit 3.3V 100 MHz (J14)
PCI-X slot 2 64-bit 3.3V 100 MHz (J13)
Battery (BH1)
PCI riser card (J16)
PCI riser card
PCI-X slot 3 64-bit
3.3V (PCI 3)133 MHz
DIMM 1 (J1)
DIMM 3 (J3)
DIMM 4 (J4)
VRM 2 (J5)
Microprocessor 2 (J6)
Microprocessor 1 (J7)
VRM 1 (J8)
PCI-X slot 4 64-bit
3.3V 133 MHz (PCI 4) PCI slot 5 32-bit
5V 33 MHz (PCI 5)
System management connector
Chapter 2. Installing options 7
Page 20
The following illustration shows how to install an adapter.
Adapter retainer
1 P O
S
2
W
U
E
P
R
P
Lig
L
V
D
I E
R
h
ia
S
M
t P
g
N
no
ath
O
R
N
s
E
tic
D
U
OV
s
N
D
E
A
R
N
N
S
T
M
P
I
E C
C
S
P
P
U
C
M
P
M
E
U
I
M
/
S
V
M
O
R
DA
R
A
M
Y
T
S
C
D
H
A
B
P C
BU
I
R
C
E
S
M
I
N
D
FA
N
T
E M
P
Complete the following steps to install a PCI or PCI-X adapter:
1. Review the information in Safetyon page v and Installation guidelineson page 5.
2. Remove the top cover.
3. Select the slot you will use for the adapter.
4. If you are installing an adapter in PCI slot 3, 4, or 5, remove the PCI riser-card assembly.
PCI riser-card assembly
Retention latch
5. Slide the expansion-slot cover out of the server or PCI riser-card assembly.
8 IBM xSeries 345 Type 8670: Installation Guide
Page 21
6. Install the adapter. The following illustration shows how to install an adapter in the PCI riser-card assembly.
PCI adapter
Adapter retainer
7. If you removed the PCI riser-card assembly to install the adapter, press the PCI riser-card assembly firmly into the connector so that the retention latch is engaged.
Note: Make sure that the PCI riser-card assembly is properly seated on the
system-board connector and that the cables under the PCI riser-card assembly are not pinched.
8. Connect any needed cables to the adapter. Attention: When you route the cables, do not block the ventilated space
around any of the fans. In addition, route any cables that are plugged into the PCI adapter under adjacent adapters so they are not pinched between the top edge of the adapter and the server side wall.
9. If you have other options to install or remove, do so now; otherwise, go to Completing the installationon page 17.
Installing memory modules
When you install memory, you must install a pair of matched double-data-rate (DDR) dual-inline-memory modules (DIMMs). Before you install memory, review the following:
v The system board contains four DIMM connectors and supports two-way memory
interleaving.
v The DIMM options available for your server are 256 MB, 512 MB, and 1 GB. v The amount of usable memory will be reduced, depending on the system
configuration. The BIOS will display the total amount of installed memory and the amount of configured memory.
v Your server supports a minimum of two 256 MB DIMMs (for a total of 512 MB)
installed in the DIMM 1 and DIMM 2 memory connectors (J1 and J2, respectively). When you install additional DIMMs, install them in pairs, with the next pair in DIMM connectors 3 and 4 (J3 and J4).
v Both DIMMs in a pair must be the same size, speed, type, and technology. You
can mix compatible DIMMs from various manufacturers.
Chapter 2. Installing options 9
Page 22
v The second pair of DIMMs do not have to be of the same size, speed, type, and
technology as the first pair.
v Install only 100 MHz, 2.5 V, 184-pin, double-data-rate (DDR), PC2100, registered
synchronous dynamic random-access memory (SDRAM) with error correcting code (ECC) DIMMs. These DIMMs must be compatible with the latest PC2100 (and downward compatible with PC1600) SDRAM Registered DIMM specification, which is available from http://www.jedec.org/ on the World Wide Web. For a list of supported options for your server, go to http://www.ibm.com/us/compat/ on the World Wide Web.
v Your server supports Chipkill
technology, if the DIMMs are all of the type 4x.
v Save new configuration information only if you replace a faulty DIMM that was
marked as Disabled in the Configuration/Setup Utility program Memory Settings menu. In this case, re-enable the memory row in the Configuration/Setup Utility program or reload the default memory settings. See the User’s Guide on the IBM xSeries Documentation CD for more information.
Install the DIMMs in the order shown in the following table:
Table 2. DIMM order of installation
Pair DIMM connectors
First 1 and 2 (J1, J2) Second 3 and 4 (J3, J4)
The following illustration shows how to install DIMMs on the system board.
DIMM 3 (J3) DIMM 4 (J4)
DIMM 1 (J1) DIMM 2 (J2)
Before you begin, read the documentation that comes with your option. Complete the following steps to install a DIMM:
1. Review the information in Safetyon page v and Installation guidelineson page 5.
2. Remove the top cover.
3. Determine the connectors into which you will install the DIMMs.
4. Install the DIMMs in the connectors.
10 IBM xSeries 345 Type 8670: Installation Guide
Page 23
5. If you have other options to install or remove, do so now; otherwise, go to Completing the installationon page 17.
Installing a hot-swap drive
Your server supports six 1-inch (26 mm) slim 3.5-inch low-voltage differential (LVD) hard disk drives.
The following illustration shows how to install a hot-swap hard disk drive.
Drive-tray assembly
Drive handle
Filler panel
Complete the following steps to install a drive in a hot-swap bay.
Notes:
1. All hot-swap drives being used in the server should have the same throughput speed rating. Mixing hard drives with different speed ratings will cause all drives to operate at the lower throughput speed.
2. The SCSI ID assigned to each bay is printed on the bezel.
Attention: To maintain proper system cooling, do not operate the server for more than 10 minutes without either a drive or a filler panel installed in each bay.
1. Review the information in Safetyon page v and Installation guidelineson page 5.
2. Remove the filler panel.
3. Place the drive handle in the open position and slide the drive into the bay.
4. Close the drive handle.
Chapter 2. Installing options 11
Page 24
Installing an additional microprocessor
Your server supports up to two microprocessors.
Attention:
v A startup (boot) microprocessor must always be installed in socket J7 on the
system board.
v To ensure proper server operation when you install an additional microprocessor,
use microprocessors that have the same cache size and type, and the same clock speed. Microprocessor internal and external clock frequencies must be identical.
Notes:
1. To order additional microprocessor options, contact your IBM reseller or IBM marketing representative.
2. When you install the microprocessor in socket J6, you must also install the voltage regulator module (VRM) that comes with the microprocessor in VRM connector J5.
3. The microprocessor speeds are automatically set for this server; therefore, you do not need to set any microprocessor frequency-selection jumpers or switches.
4. If you need to replace a microprocessor, call for service.
The following illustration is a simplified layout of the microprocessor connector locations and other microprocessor-related components on the system board.
VRM 2 connector (J5)
Microprocessor 2 (J6)
Microprocessor 1 (J7)
VRM 1 connector (J8)
12 IBM xSeries 345 Type 8670: Installation Guide
Page 25
The following illustration shows how to install the second microprocessor on the system board.
Note: Do not remove the first microprocessor from the system board to install the
second microprocessor.
Captive screws
Heat sink
Microprocessor
VRM
Microprocessor release lever
Complete the following steps to install an additional microprocessor:
1. Review the information in Safetyon page v and Installation guidelineson page 5.
2. Remove the top cover.
3. Remove the air baffle.
Chapter 2. Installing options 13
Page 26
4. Remove the air baffle from the empty microprocessor socket and store the air baffle for future use.
1 P
O
S
2
W
U
E
P
R
P
L
L
i
V
g
D
I
E
R
h
i
S
M
a
t
g
P
N
n
a
O
R
o
t
N
h
s
E
t
D
i
c
U
OV
s
N
D
E
A
R
N
S
N
T
M
P
I
E
C
C
S
P
P
U
C
MEMORY
P
M
U
I
/V
S
M
R
DA
A
M
T
S
C
D
H
A
B
P
C
BU
I
R
C
E
S
M
I
N
D
FA
N
T
E
M
P
5. Install a VRM in the VRM connector (J5) and install the metal clip over the VRM.
6. Locate the second microprocessor socket (connector J6) on the system board.
14 IBM xSeries 345 Type 8670: Installation Guide
Page 27
7. Install the microprocessor:
Attention:
v Do not use excessive force when pressing the microprocessor into the
socket.
v Make sure that the microprocessor is oriented and aligned correctly with pin
number 1 in the socket before you try to close the lever. The following illustration shows the alignment marks for microprocessor 2 and microprocessor socket 2.
a. Center the microprocessor over the microprocessor socket. Align the
triangle on the corner of the microprocessor with the triangle on the corner of the socket and carefully press the microprocessor into the socket.
Microprocessor 2
Alignment marks
Microprocessor socket 2
b. Carefully close the microprocessor-release lever to secure the
microprocessor in the socket.
8. Install a heat sink on the microprocessor:
Attention:
v Do not set the heat sink down after you remove the plastic cover.
Thermal grease
Heat sink
v Do not touch the thermal grease on the bottom of the heat sink. Touching
the thermal grease will contaminate it. If the thermal grease on the microprocessor or heat sink becomes contaminated, contact your service
technician. a. Remove the plastic protective cover from the bottom of the heat sink. b. Align and place the heat sink on top of the microprocessor with the thermal
grease side down. Press firmly on the heat sink. Attention: If you do not alternate the tightening of the two captive
screws, you might damage the microprocessor. Ensure that the screws are completely tightened; otherwise, the server will not function properly.
c. Secure the heat sink to the microprocessor by tightening the captive
screws. Alternate between the two captive screws in the heat sink while tightening them.
9. Install the air baffle.
10. If you have other options to install or remove, do so now; otherwise, go to Completing the installationon page 17.
Chapter 2. Installing options 15
Page 28
Installing a hot-swap power-supply option
Your server supports a maximum of two hot-swap power supplies.
Note: Hot-swap fans come with the power-supply option.
Statement 8
CAUTION: Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.
The following illustration shows how to install a hot-swap power supply.
Power supply
Handle (open position)
AC power LED (green)
DC power LED (green)
16 IBM xSeries 345 Type 8670: Installation Guide
Power supply blank (some models)
Page 29
Complete the following steps to install a power supply:
1. Review the information in Safetyon page v and Installation guidelineson
page 5.
2. (Some models) Remove the power-supply blank from the empty power-supply
bay by pinching the side clip and pulling the power-supply blank from the bay. Save the power-supply blank in case you remove the power supply at a later time.
Attention: During normal operation, each power-supply bay must have either a power supply or power-supply blank installed for proper cooling.
3. Move the handle on the power supply into the open position and slide the power
supply into the chassis.
4. Gently close the handle to seat the power supply into the bay.
5. Plug the power cord for the new power supply in the power-cord connector on
the back of the server.
6. If you have other options to install or remove, do so now; otherwise, go to
Completing the installation.
Note: When you turn on the server, verify that the dc power LED and ac power
LED on the power supply are lit, indicating that the power supply is operating correctly.
Completing the installation
Complete the following steps to complete the installation:
1. Install the top cover.
2. Install the server in a rack. See the Rack Installation Instructions that come with
your server for complete rack installation and removal instructions.
Attention:
v Install your server only in a rack cabinet with perforated doors. v Do not leave open spaces above or below an installed server in your rack
cabinet. To help prevent damage to server components, always install a blank filler panel to cover the open space and to help ensure proper air circulation. See the documentation that comes with your rack cabinet for more information.
v Install your server in a rack that meets the following requirements:
– Minimum depth of 70 mm (2.76 in.) between the front mounting flange and
the inside of the front door.
– Minimum depth of 157 mm (6.18 in.) between the rear mounting flange
and the inside of the rear door.
– Minimum depth of 718 mm (28.27 in.) and maximum depth of 762 mm
(30.00 in.) between the front and rear mounting flanges.
3. Plug in all cables and power cords.
The following illustrations show the locations of the input and output connectors on your server. Detailed cabling instructions are in the Rack Installation Instructions that come with your server.
Notes:
1. You must turn off the server before connecting cables to or disconnecting any
cables from the server (see Turning off the serveron page 22).
Chapter 2. Installing options 17
Page 30
2. See the documentation that comes with your options for additional cabling instructions. It might be easier for you to route cables before you install certain options.
3. Cable identifiers are printed on the cables that come with your server and options. Use these identifiers to connect the cables to the correct connectors.
Rear view
Mouse
Universal Serial Bus (USB)
Serial Video
1 and 2
Keyboard
Front view
Ethernet 1
Ethernet 2
USB 3
RS 485-A (ISMP)
SCSI
RS 485-B (ISMP)
18 IBM xSeries 345 Type 8670: Installation Guide
Page 31
Chapter 3. Server power, controls, and indicators
This section identifies the controls and indicators on the front and rear of your server. It also describes the power features of your server.
Front view
SCSI or IDE
Power-on LED (green)
Power-control button
Reset button
bus activity LED (green)
System-error
(amber)LED
CD-ROM drive activity (green)LED
CD-eject button
Diskette drive activity
LED
(green)
Diskette-eject button
System
identification LED
(blue)
Information (amber)
LED
Hard disk drive activity
LED
(green)
Hard disk drive status
LED
(amber)
Power-on LED: This green LED is lit and stays on when you turn on your server and flashes when the server is in Standby mode.
Attention: If the power-on light-emitting diode (LED) is off, it does not mean that there is no electrical current present in the server. The LED might be burned out. To remove all electrical current from the server, you must unplug the server power cords from the electrical outlets or from the uninterruptible power device.
Power-control button: Press this button to manually turn on the server and put the server in Standby mode (see Turning on the serveron page 21).
Reset button: Press this button to reset the server and run the power-on self-test (POST). You might need to use a pen or the end of a straightened paper clip to press the button.
SCSI or IDE bus activity LED: This green LED is lit when there is activity on the SCSI or IDE bus.
System error LED: This amber LED is lit when a system error occurs. An LED on the diagnostic LED panel will also be on to further isolate the error.
CD-ROM drive activity LED: When this LED is lit, it indicates that the CD-ROM drive is in use.
CD-eject button: Press this button to release a CD from the drive. Diskette drive activity LED: When this LED is lit, it indicates that the diskette drive
is in use. Diskette-eject button: Press this button to release a diskette from the drive.
© Copyright IBM Corp. 2002 19
Page 32
Rear view
Hard disk drive status LED: Each hot-swap drive has a hard disk drive status
LED. When this amber LED is lit continuously, the drive has failed. If a RAID adapter is installed in the server, when the LED flashes slowly (one flash per second), the drive is being rebuilt. When the LED flashes rapidly (three flashes per second), the controller is identifying the drive.
Hard disk drive activity LED: Each of the hot-swap drives has a hard disk drive activity LED. When this green LED is flashing, the controller is accessing the drive.
Information LED: This amber LED is lit when the information log contains information about certain conditions in your server that might affect performance. For more information, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD.
System-identification LED: This blue LED is lit in response to a programmed condition, or it can be turned on remotely by the system administrator to aid in server identification for maintenance. The system administrator can turn off the system identification LED after maintenance is complete.
Ethernet 1 (green)
Ethernet 2 activity (green)
Ethernet 2 link status (green)
Ethernet 1 link status (green)
activity LED
LED
LED
LED
DC power (green)
LED
AC power (green)
LED
Ethernet 2 activity LED: This green LED is lit when the server is transmitting to or receiving signals from the Ethernet LAN that is connected to Ethernet port 2.
Ethernet 2 link status LED: This green LED is lit when there is an active link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for Ethernet port 2.
AC power LED: This green LED provides status information about the power supply. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD.
DC power LED: This green LED provides status information about the power supply. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD.
20 IBM xSeries 345 Type 8670: Installation Guide
Page 33
Ethernet 1 link status LED: This green LED is lit when there is an active link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for Ethernet port 1.
Ethernet 1 activity LED: This green LED is lit when the server is transmitting to or receiving signals from the Ethernet LAN that is connected to Ethernet port 1.
Server power features
This section contains information about how to properly turn your server on and off.
Turning on the server
You can turn on the server in any of the following ways: v If the power cords are connected to a power source, you can press the
power-control button on the front of the server. Note: You can install a circular disk over the power-control button to prevent
v If the server is turned on and a power failure occurs, it restarts automatically
when power is restored.
v You can turn on the server by using the optional Remote Supervisor Adapter. v You can turn on the server by using the Integrated System Management
Processor (ISMP)
v When you plug in your server for the first time, Wake on LAN
server.
v If your server was previously turned on, it must be properly placed in Standby
mode for the Wake on LAN feature to turn on the server.
accidental manual power-off. This disk, known as the power-control button shield, comes with your server.
can turn on the
Complete the following steps to manually turn on the server:
1. Review the information in Safetyon page v.
2. Turn on all external devices, such as the monitor.
3. Plug the server power cords into the power source.
4. Press the power-control button on the front of the server. Note: While the server is powering up, the power-on LED on the front of the server
is lit.
Chapter 3. Server power, controls, and indicators 21
Page 34
Turning off the server
Complete the following steps to manually turn off the server:
1. Review the information in Safetyon page v.
2. See your operating system documentation for the proper procedure to shut down the operating system.
Statement 5
CAUTION: The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2 1
3. Press the power-control button on the front of the server. This will put the server in Standby mode.
4. Disconnect the server from the power source.
Standby mode
Notes:
a. After you turn off the server, wait at least 5 seconds before you turn on the
server again.
b. You might need to press and hold the power-control button for more than 4
seconds to cause an immediate shutdown of the server and to force the power off. You can use this feature if the operating system stops functioning.
Standby mode refers to the condition in which the server operating system is not running and all core logic is shut down except for the service processor.
Complete the following steps to put the server into Standby mode:
1. See the operating system documentation for the proper procedure to shut down the operating system.
Note: Each operating system is different. Read all the documentation about
shutting down the operating system before continuing.
2. Press the power-control button on the front of the server.
You can put the server into Standby mode remotely by using the service processor.
22 IBM xSeries 345 Type 8670: Installation Guide
Page 35
Chapter 4. Configuring your server
The ServerGuide™Setup and Installation CD provides software setup tools and installation tools that are specifically designed for your IBM server. Use this CD during the initial installation of your server to configure basic hardware features and to simplify your operating system installation. (See Using the ServerGuide Setup and Installation CDfor more information.)
In addition to the ServerGuide Setup and Installation CD, you can use the following configuration programs to customize your server hardware:
v Configuration/Setup Utility
This program is part of the basic input/output system (BIOS) code that comes with your server. You can use this program to configure serial port assignments, change interrupt request (IRQ) settings, change the drive startup sequence, set the date and time, and set passwords. For information on using this utility, see Using the Configuration/Setup Utility programon page 24.
v ServeRAID programs
The ServeRAID programs come with your server. If your server has a ServeRAID adapter installed or if you are using the RAID capabilities of the integrated SCSI controller, you can use the ServeRAID Manager program to define and configure your disk-array subsystem before you install your operating system. For information about using this utility, see Using ServeRAID Manageron page 24.
v LSI Logic Configuration Utility
With the built-in LSI Logic Configuration Utility program, you can configure the integrated SCSI controller and the devices that attach to it. See Using the LSI Logic Configuration Utility programon page 25.
v IBM Director
IBM Director is a work-group-hardware-management tool that you can use to centrally manage xSeries servers; IBM Netvista computers; and non-IBM Intel-microprocessor-based systems. IBM Director automates tasks such as inventory-taking, monitoring of environmental sensors (such as temperature, voltage and fans), alerting, and system-health information.
For more information and instructions about IBM Director, see the IBM Director Users Guide on the IBM Director CD that comes with your server.
, IntelliStation®, and ThinkPad
®
See the Users Guide on the IBM xSeries Documentation CD for detailed instructions for using the configuration programs and the ServerGuide Setup and Installation CD.
Using the ServerGuide Setup and Installation CD
The ServerGuide Setup and Installation CD provides state-of-the-art programs to detect the server model and hardware options that are installed, configures the server hardware, provides device drivers, and helps to install your operating system.
Note: If the ServerGuide Setup and Installation CD does not start, see
ServerGuide problemson page 29.
Complete the following steps to start the ServerGuide Setup and Installation CD.
1. Insert the ServerGuide Setup and Installation CD, and restart the server.
2. Follow the instructions that appear on the screen to:
© Copyright IBM Corp. 2002 23
Page 36
a. Select your language. b. Select your keyboard layout and country. c. View the overview to learn about ServerGuide features. d. View the README file to review installation tips about your operating
system and adapter. e. Start the setup and hardware configuration programs. f. Start the operating system installation. You will need your copy of the
operating system CD. Note: For information about the supported operating system versions, see
the ServerGuide Setup and Installation CD label.
Using the Configuration/Setup Utility program
The Configuration/Setup Utility program is a menu-driven utility program that is part of the BIOS code that comes with your server. You can use it to:
v Configure serial port assignments v Change the drive startup sequence v Enable USB keyboard and mouse support v Resolve configuration conflicts v Set the date and time v Set passwords
Complete the following steps to start the Configuration/Setup Utility program:
1. Turn on the server (see Turning on the serveron page 21) and watch the monitor screen.
2. When the message Press F1 for Configuration/Setup appears, press F1.
3. Follow the instructions that appear on the screen.
Using ServeRAID Manager
You can use the ServeRAID Manager program, provided on the IBM ServeRAID Support CD, to:
v Configure a redundant array of independent disks (RAID) v Restore a SCSI hard disk drive to factory-default settings, erasing all data v View your RAID configuration and associated devices v Monitor operation of your RAID controllers
The ServeRAID Manager program operates in two ways:
v Startable CD mode v As an installed software program
See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID technology and instructions for using ServeRAID Manager.
Notes:
1. The integrated SCSI controller with RAID capabilities in your server supports only RAID level 1 operation.
24 IBM xSeries 345 Type 8670: Installation Guide
Page 37
2. If your server has a ServeRAID-5i controller installed, you can use ServeRAID Manager to configure the integrated SCSI controller with RAID capabilities for other supported RAID levels.
Using the LSI Logic Configuration Utility program
The LSI Logic Configuration program is a built-in, menu-driven configuration utility program. You can use it to:
v Perform a low-level format on a hard disk drive v Set the SCSI device scan order v Set the SCSI ID for a controller
Notes:
1. The integrated SCSI controller with RAID capabilities in your server supports RAID level 1 operation. Installing an optional ServeRAID-5i controller provides additional RAID levels. See Using ServeRAID Manageron page 24 for information on configuring your server for RAID operation.
2. If you install a different type of RAID controller in your server, use the configuration method supplied with the RAID controller to view or change SCSI settings for attached devices.
Complete the following steps to start the LSI Logic Configuration Utility program:
1. Turn on the server (see Turning on the serveron page 21) and watch the monitor screen.
2. When the Press CTRL C to start LSI Logic Configuration Utility prompt appears, press Ctrl+C.
Note: If an administrator password has been set, a prompt appears asking you
to type the password to start the LSI Logic Configuration Utility program.
3. Use the arrow keys to select a controller (channel) from the list of adapters; then, press Enter.
4. Follow the instructions on the screen to change the settings of the selected items; then, press Enter.
Chapter 4. Configuring your server 25
Page 38
26 IBM xSeries 345 Type 8670: Installation Guide
Page 39
Chapter 5. Solving problems
This section provides basic troubleshooting information to help you resolve some common problems that might occur while setting up your server.
If you cannot locate and correct the problem using the information in this section, see the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information.
Diagnostic tools overview
The following tools are available to help you identify and resolve hardware-related problems:
v POST beep codes
The power-on self-test beep codes indicate the detection of a problem.
One beep indicates successful completion of POST.More than one beep indicates that POST detected a problem. Error messages
also appear during startup if POST detects a hardware-configuration problem.
See POST beep code descriptionsand the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information.
v Troubleshooting charts
These charts list problem symptoms and steps to correct the problem. See the Troubleshooting charton page 30 for more information.
v Diagnostic programs and error messages
The system diagnostic programs are provided in ROM. These programs test the major components of your server. See the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information.
v Light Path Diagnostics feature
Use the Light Path Diagnostics feature to identify system errors quickly. See the
Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information.
POST beep code descriptions
POST emits one beep to signal successful completion. If POST detects a problem during startup, other beep codes might occur. You can use the following beep code descriptions to help identify and resolve problems that are detected during startup.
Note: See the Hardware Maintenance Manual and Troubleshooting Guide on the
IBM xSeries Documentation CD for more information about the POST beep codes.
Table 3. POST beep code descriptions
Beep code Descriptions of the POST beep codes
No beep Call for service. Continuous If no video appears, the startup microprocessor failed. Verify that the startup microprocessor is
installed correctly. If it is, call for service.
© Copyright IBM Corp. 2002 27
Page 40
Table 3. POST beep code descriptions (continued)
Beep code Descriptions of the POST beep codes
One short POST completed successfully. One beep also occurs after POST if you enter an incorrect
password. Two short Follow the instructions that appear on the screen. Three short POST detected a system memory error. Verify that the memory is installed correctly. If it is,
replace the failing memory module. Repeating short The system board might contain a failing component.
1. Verify that the keyboard and pointing devices are connected properly.
2. Ensure that nothing is resting on the keyboard.
3. Disconnect the pointing device; then, restart the server. If the problem goes away, replace the pointing device. If the problem remains, call for service.
One long and one short
One long and two short
One long and three short
Two long and two short
All other beep codes
If the video controller on the system board is being used, call for service. If you installed an optional video adapter, replace the failing adapter.
A video I/O adapter ROM is not readable, or the video subsystem is defective. If you installed an optional video adapter, replace the failing adapter. If the problem remains, call for service.
The system-board video subsystem has not detected a monitor connection to the server. Ensure that the monitor is connected to the server. If the problem remains, replace the monitor.
POST does not support the optional video adapter. Replace the optional video adapter with one that is supported by the server or use the integrated video controller.
1. Verify that the system memory modules are installed correctly.
2. Turn off the server; then, restart the server. If the problem remains, call for service.
POST error messages
The following table provides an abbreviated list of the error messages that might appear during POST.
Note: See the Hardware Maintenance Manual and Troubleshooting Guide on the
IBM xSeries Documentation CD for more information about the POST error messages.
Table 4. Abbreviated list of POST error messages
POST message Failing device or problem
found
129 L1 cache of a microprocessor Check the installation of your microprocessors. 162 Change in device
configuration 163 Time of day has not been set Set the correct date and time. 164 Change in memory
configuration 201 Change in memory
configuration 229 L2 cache of a microprocessor Check the installation of your microprocessors. 289 Failing DIMM was disabled Verify that your memory is correct for your server and that it is
301 303
11xx Serial port error Verify that the serial cable is connected correctly.
Keyboard and keyboard
controller
Suggested action
Verify that your optional devices are turned on and installed correctly.
Verify that your memory is installed properly; then, restart the server and run the Configuration/Setup Utility program.
Verify that your memory is fully seated and installed properly.
installed properly. Ensure that the keyboard cable is connected and nothing is
resting on the keyboard keys.
28 IBM xSeries 345 Type 8670: Installation Guide
Page 41
Table 4. Abbreviated list of POST error messages (continued)
POST message Failing device or problem
found
1162 Serial port configuration
conflict
1601 BIOS code update needed Download and install the latest level of system BIOS code. 1800 PCI adapter hardware
interrupt
2400 2462
00019xxx Processor x is not functioning
00180xxx A PCI adapter requested a
012980xx 012981xx
01298200 Microprocessor speed
I9990305 POST could not find an
Video controller and memory Verify that the monitor is connected correctly.
or failed the built-in test
resource that is not available Data for processor x Download and install the latest level of system BIOS code.
mismatch
operating system.
Suggested action
Start the Configuration/Setup Utility program and ensure that the IRQ and I/O port assignments needed by the serial port are available.
Start the Configuration/Setup Utility program and verify that the interrupt resource settings are correct.
Verify that processor x is installed correctly. If the problem remains, replace processor x.
Start the Configuration/Setup Utility program and ensure that the resources needed by the PCI adapter are available.
Install microprocessors with identical speeds.
Install your operating system.
ServerGuide problems
The following table lists problem symptoms and suggested solutions.
Table 5. ServerGuide Setup and Installation CD
Symptom Suggested action
The ServerGuide Setup and Installation CD will
not start.
The SCSI RAID program cannot view all installed drives, or the NOS cannot be installed.
The Operating System Installation program continuously loops.
The ServerGuide program will not start your NOS CD.
The NOS cannot be installed; the option is not available.
v Ensure that the server is supported and has a startable (bootable) CD-ROM drive. v If the startup (boot) sequence settings have been altered, ensure that the CD-ROM
drive is first in the startup sequence.
v If more than one CD-ROM drive is installed, ensure that only one drive is set as the
primary drive. Start the CD from the primary drive.
v Ensure that there are no duplicate SCSI IDs or IRQ assignments. v Ensure that the hard disk drive is connected properly.
Make more space available on the hard disk.
Ensure that the NOS CD you have is supported by the ServerGuide program. See the ServerGuide Setup and Installation CD label for a list of supported NOS versions.
Ensure that the NOS is supported on your server. If the NOS is supported, either there is no logical drive defined (SCSI RAID systems) or the ServerGuide System Partition is not present. Run the ServerGuide program, and ensure that setup is complete.
Chapter 5. Solving problems 29
Page 42
Troubleshooting chart
Notes:
1. See the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more detailed troubleshooting charts.
2. If you cannot find the problem in the troubleshooting charts, run the diagnostic programs. If you have run the diagnostic test programs, or if running the tests does not reveal the problem, call for service.
Table 6. Troubleshooting charts
Symptom Suggested action
CD-ROM drive problems Verify that:
v The IDE channel to which the CD-ROM drive is attached (primary or secondary)
is enabled in the Configuration/Setup Utility program.
CD-ROM drive is not recognized.
Diskette drive problems If there is a diskette in the drive, verify that:
Diskette drive activity LED stays on, or the system bypasses the diskette drive.
Expansion enclosure
problems
The SCSI expansion enclosure used to work but does not work now.
General problems Call for service.
Problems such as broken cover locks or indicator LEDs not working.
Hard disk drive problems
Not all drives are recognized by the hard disk drive diagnostic test (Fixed Disk test).
System stops responding during hard disk drive diagnostic test.
Note: On systems with a single IDE channel, only the primary channel can be used.
v All cables and jumpers are installed correctly. v The correct device driver is installed for the CD-ROM drive.
v The diskette drive is enabled in the Configuration/Setup Utility program. v The diskette is good and not damaged. (Try another diskette if you have one.) v The diskette contains the necessary files to start the server. v Your software program is working properly.
If the diskette drive activity LED stays on, or the system continues to bypass the diskette drive, call for service.
Verify that:
v The cables for all external SCSI options are connected correctly. v The last option in each SCSI chain, or the end of the SCSI cable, is terminated
correctly.
v Any external SCSI option is turned on. You must turn on an external SCSI option
before turning on the server.
For more information, see your SCSI expansion enclosure documentation.
1. Remove the first drive not recognized and try the hard disk drive diagnostic test again.
2. If the remaining drives are recognized, replace the drive you removed with a new one.
1. Remove the hard disk drive being tested when the server stopped responding and try the diagnostic test again.
2. If the hard disk drive diagnostic test runs successfully, replace the drive you removed with a new one.
30 IBM xSeries 345 Type 8670: Installation Guide
Page 43
Table 6. Troubleshooting charts (continued)
Symptom Suggested action
Intermittent problems Verify that:
v All cables and cords are connected securely to the rear of the server and
attached options.
v When the server is turned on, air is flowing from the rear of the server at the fan
A problem occurs only occasionally and is difficult to detect.
grill. If there is no airflow, the fan is not working. This causes the server to overheat and shut down.
v Ensure that the SCSI bus and devices are configured correctly and that the last
external device in each SCSI chain is terminated correctly.
If you have verified these items and the problem remains, call for service.
Keyboard, mouse, or
pointing-device problems.
All or some keys on the keyboard do not work.
The mouse or pointing device does not work.
v Make sure that the keyboard cable is properly connected to the server. v Make sure that the server and the monitor are turned on. v Try using another keyboard.
If the problem remains, call for service. v Verify that the mouse or pointing-device cable is securely connected and the
device drivers are installed correctly.
v Try using another mouse or pointing device. If the problem remains, call for service.
Memory problems Verify that:
v The memory modules are seated properly. v You have installed the correct type of memory. v If you changed the memory, you updated the memory configuration with the
Configuration/Setup Utility program.
v All banks of memory on the DIMMs are enabled. The server might have
automatically disabled a DIMM bank when it detected a problem or a DIMM bank could have been manually disabled.
The amount of system memory displayed is less than the amount of physical memory installed.
Look in the POST error log for error message 289: v If the DIMM was disabled by a system-management interrupt (SMI), replace the
DIMM.
v If the DIMM was disabled by the user or by POST:
1. Start the Configuration/Setup Utility program.
2. Enable the DIMM.
3. Save the configuration and restart the server.
v If you continue to get this error, replace the DIMM.
Microprocessor problems The startup (boot) microprocessor is not working properly.
The server emits a continuous tone during POST.
Monitor problems Some IBM monitors have their own self-tests. If you suspect a problem with your
Testing the monitor.
The screen is blank. Verify that:
If the problem remains, call for service.
Verify that the startup microprocessor is seated properly. If it is, call for service.
monitor, see the information that comes with the monitor for adjusting and testing instructions.
If you still cannot find the problem, call for service.
v The server power cord is plugged into the server and a working electrical outlet. v The monitor cables are connected properly. v The monitor is turned on and the Brightness and Contrast controls are adjusted
correctly.
If you have verified these items and the screen remains blank, call for service.
Chapter 5. Solving problems 31
Page 44
Table 6. Troubleshooting charts (continued)
Symptom Suggested action
Only the cursor appears. Call for service. The monitor works when you
Verify that you installed the necessary device drivers for the application. turn on the server but goes blank when you start some
If the items above are correct and the screen remains blank, call for service. application programs.
The screen is wavy, unreadable, rolling, distorted, or has screen jitter.
If the monitor self-tests show the monitor is working properly, consider the location
of the monitor. Magnetic fields around other devices (such as transformers,
appliances, fluorescent lights, and other monitors) can cause screen jitter or wavy,
unreadable, rolling, or distorted screen images. If this happens, turn off the monitor.
(Moving a color monitor while it is turned on might cause screen discoloration.)
Then move the device and the monitor at least 305 mm (12 in.) apart. Turn on the
monitor.
Notes:
1. To prevent diskette drive read/write errors, be sure the distance between monitors and diskette drives is at least 76 mm (3 in.).
2. Non-IBM monitor cables might cause unpredictable problems.
3. An enhanced monitor cable with additional shielding is available for the 9521 and 9527 monitors. For information about the enhanced monitor cable, contact your IBM reseller or IBM marketing representative.
If the problem remains, call for service.
Wrong characters appear on the screen.
If the wrong language is displayed, update the BIOS code with the correct language.
Option problems Verify that:
An IBM option that was just installed does not work.
An IBM option that used to work does not work now.
If the problem remains, call for service.
v The option is designed for the server. See the Server Supportflowchart for
information about obtaining ServerProven
compatibility information from the
World Wide Web.
v You followed the installation instructions that came with the option. v The option is installed correctly. v You have not loosened any other installed options or cables. v You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or an option is changed, you must update the configuration.
If the problem remains, call for service. Verify that all of the option hardware and cable connections are secure.
If the option comes with its own test instructions, use those instructions to test the option.
If the failing option is a SCSI option, verify that:
v The cables for all external SCSI options are connected correctly. v The last option in each SCSI chain, or the end of the SCSI cable, is terminated
correctly.
v Any external SCSI option is turned on. You must turn on an external SCSI option
before turning on the server.
If the problem remains, call for service.
32 IBM xSeries 345 Type 8670: Installation Guide
Page 45
Table 6. Troubleshooting charts (continued)
Symptom Suggested action
Power problems Verify that:
v The power cables are properly connected to the server. v The electrical outlet functions properly. v The type of memory installed is correct.
The server does not turn on.
v If you just installed an option, remove it, and restart the server. If the server now
turns on, you might have installed more options than the power supply supports.
If the problem remains, call for service.
The server does not turn off. Verify whether you are using an ACPI or non-ACPI operating system.
If you are using a non-ACPI operating system:
1. Press Ctrl+Alt+Delete.
2. Turn off the system by using the power-control button. If the problem remains or if you are using an ACPI-aware operating system, call for
service.
Serial port problems Verify that:
The number of serial ports identified by the operating system is less than the number of serial ports installed.
A serial device does not work. For more information about the serial port, see the Option
Installation Guide on the IBM xSeries Documentation CD.
v Each port is assigned a unique address by the Configuration/Setup Utility
program and none of the serial ports are disabled.
v The serial-port adapter, if you installed one, is seated properly. If the problem remains, call for service. Verify that:
v The device is compatible with the server. v The serial port is enabled and is assigned a unique address.
If the problem remains, call for service.
Software problem To determine if problems are caused by the software, verify that:
v Your server has the minimum memory needed to use the software. For memory
requirements, see the information that comes with the software. Note: If you have just installed an adapter or memory, you might have a memory address conflict.
v The software is designed to operate on your server. v Other software works on your server.
Suspected software problem.
v The software that you are using works on another system. If you received any error messages when using the software program, see the
information that comes with the software for a description of the messages and suggested solutions to the problem.
Universal Serial Bus (USB)
port problems
A USB device does not work.
If you have verified these items and the problem remains, contact your place of purchase.
Verify that: v You are not trying to use a USB device during POST if you have a standard
(non-USB) keyboard attached to the keyboard port. Note: If a standard (non-USB) keyboard is attached to the keyboard port, the USB is disabled and no USB device will work during POST.
v The correct USB device driver is installed. v Your operating system supports USB devices.
If the problem remains, call for service.
Chapter 5. Solving problems 33
Page 46
34 IBM xSeries 345 Type 8670: Installation Guide
Page 47
Chapter 6. Getting help and technical assistance
If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This section contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your xSeries or IntelliStation system, and whom to call for service, if it is necessary.
Before you call
Before you call, make sure that you have taken these steps to try to solve the problem yourself:
v Check all cables to make sure that they are connected. v Check the power switches to make sure that the system is turned on. v Use the troubleshooting information in your system documentation, and use the
diagnostic tools that come with your system.
v Go to the IBM Support Web site at http://www.ibm.com/pc/support/ to check for
technical information, hints, tips, and new device drivers.
v Use an IBM discussion forum on the IBM Web site to ask questions. You can solve many problems without outside assistance by following the
troubleshooting procedures that IBM provides in the online help or in the publications that are provided with your system and software. The information that comes with your system also describes the diagnostic tests that you can perform. Most xSeries and IntelliStation systems, operating systems, and programs come with information that contains troubleshooting procedures and explanations of error messages and error codes. If you suspect a software problem, see the information for the operating system or program.
Using the documentation
Information about your IBM xSeries or IntelliStation system and preinstalled software, if any, is available in the documentation that comes with your system. That documentation includes printed books, online books, README files, and help files. See the troubleshooting information in your system documentation for instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. To access these pages, go to http://www.ibm.com/pc/support/ and follow the instructions. Also, you can order publications through the IBM Publications Ordering System at http://www.elink.ibmlink.ibm.com/public/applications/publications/cgibin/pbi.cgi.
Getting help and information from the World Wide Web
On the World Wide Web, the IBM Web site has up-to-date information about IBM xSeries and IntelliStation products, services, and support. The address for IBM xSeries information is http://www.ibm.com/eserver/xseries/. The address for IBM IntelliStation information is http://www.ibm.com/pc/intellistation/.
© Copyright IBM Corp. 2002 35
Page 48
You can find service information for your IBM products, including supported options, at http://www.ibm.com/pc/support/. If you click Profile from the support page, you can create a customized support page. The support page has many sources of information and ways for you to solve problems, including:
v Diagnosing problems, using the IBM Online Assistant v Downloading the latest device drivers and updates for your products v Viewing Frequently Asked Questions (FAQ) v Viewing hints and tips to help you solve problems v Participating in IBM discussion forums v Setting up e-mail notification of technical updates about your products
Software service and support
Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with xSeries servers, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country, go to http://www.ibm.com/services/sl/products/.
For more information about Support Line and other IBM services, go to http://www.ibm.com/services/, or go to http://www.ibm.com/planetwide/ for support telephone numbers.
Hardware service and support
You can receive hardware service through IBM Integrated Technology Services or through your IBM reseller, if your reseller is authorized by IBM to provide warranty service. Go to http://www.ibm.com/planetwide/ for support telephone numbers.
In the U.S. and Canada, hardware service and support is available 24 hours a day, 7 days a week. In the U.K., these services are available Monday through Friday, from 9 a.m. to 6 p.m.
36 IBM xSeries 345 Type 8670: Installation Guide
Page 49
Appendix A. Warranty information
This section contains information about your warranty period and the service and support that are provided by your warranty.
Warranty period
The warranty period varies by machine type and country or region. Contact your place of purchase for warranty service information. Some IBM
Machines are eligible for on-site warranty service depending on the country or region where service is performed.
Prior to on-site warranty service, you are required to go through problem determination with an IBM service specialist call center technician.
A warranty period of 3 years on parts and 1 year on labor means that IBM will provide warranty service without charge for:
1. parts and labor during the first year of the warranty period
2. parts only, on an exchange basis, in the second and third years of the warranty period. IBM will charge you for any labor it provides in performance of the repair or replacement.
The IBM Machine Warranties Web site at http://www.ibm.com/servers/support/machine_warranties/ contains a worldwide overview of the IBM Statement of Limited Warranty for IBM Machines, a glossary of terms used in the Statement of Limited Warranty, Frequently Asked Questions (FAQ), and links to Product Support Web pages. The IBM Statement of Limited Warranty is available from this Web site in 29 languages in Portable Document Format (PDF).
Machine - IBM Eserver xSeries 345 Type 8670
Country or region Warranty period Service delivery method
Japan Parts - 3 years, Labor - 1
All other countries or regions Parts - 3 years, Labor - 3
Problem determination
Prior to on-site warranty service, you are required to go through problem determination with an IBM service specialist call center technician. The service specialist will run diagnostic tests on the hardware and check the software.
Running diagnostics
The IBM service specialist will help you determine whether your equipment is functioning as specified. It might be necessary to isolate the failing xSeries, Netfinity, or IntelliStation system; IBM component; or both from any active production environment to run diagnostics and perform defect-isolation programs. You are responsible for making the system, IBM component, or both available for running diagnostics and defect-isolation programs.
On-site repair
year
On-site repair
years
© Copyright IBM Corp. 2002 37
Page 50
Checking software
The IBM service specialist will help you ensure that the correct BIOS code, firmware, device drivers, and other supporting IBM software are installed and correctly configured. It might be necessary to manually gather information about the relevant software levels or run IBM-approved utility programs to gather this information. It might be necessary to isolate the failing system from any active production environment to gather this information. You are responsible, with assistance from the service specialist, for gathering this information. The IBM Statement of Limited Warranty does not include on-site assistance with this activity.
Warranty service and support
With the original purchase of an IBM xSeries or IntelliStation system, you have access to extensive service and support. During the IBM Machine warranty period, you may call IBM or your reseller for problem-determination assistance under the terms of the IBM Statement of Limited Warranty.
The following services are available during the warranty period: v Problem determination - Trained personnel are available to assist you with
determining if you have a hardware problem and deciding what action is necessary to fix the problem.
v IBM hardware repair - If the problem is determined to be caused by IBM
hardware under warranty, trained service personnel are available to provide the applicable level of service, either on-site or at an IBM service center as determined by IBM.
v Engineering Change management - Occasionally, there might be changes that
are required after a product has been shipped from IBM. In those instances, IBM will make Engineering Changes (ECs) available that apply to your hardware.
v Customer replaceable units (CRUs) - Some parts of IBM servers are
designated as customer replaceable units. IBM ships CRUs to you for replacement by you. CRUs include keyboards, monitors, memory, diskette drives, hard disk drives, and mice (this list is not inclusive of all CRUs).
The following items are not covered under warranty service: v Replacement or use of non-IBM parts. All IBM parts contain a 7-character
identification in the format IBM FRU XXXXXXX.
v Identification of software problem sources. v Installation of customer replaceable units (CRUs). v Installation and configuration of BIOS code, firmware, or device drivers that are
designated as customer installable.
See the IBM Statement of Limited Warranty for a full explanation of IBM warranty terms. Be sure to retain your proof of purchase to obtain warranty service.
Please have the following information ready when you call:
v The machine type and model of your IBM hardware product (if available) v Serial numbers of your IBM hardware products v A description of the problem v The exact wording of any error messages v Hardware and software configuration information
38 IBM xSeries 345 Type 8670: Installation Guide
Page 51
International Warranty Service
If you travel with your xSeries or IntelliStation system or relocate it to a country where your system is sold and serviced by IBM or IBM resellers authorized to perform warranty service, International Warranty Service (IWS) is available during the warranty period. Eligible IBM systems are identified by their four-digit machine types.
You can obtain IWS through the service delivery method (such as depot, carry-in, or on-site) provided in the servicing country. Service methods and procedures vary by country, and some service or parts might not be available in all countries. Service centers in certain countries might not be able to service all models of a particular machine type. In addition, some countries might have fees and restrictions that apply at the time of service.
To determine whether your system is eligible for IWS, go to http://www.ibm.com/pc/support/ and click Warranty lookup.
Purchasing additional services
During and after the warranty period, you can purchase additional services, such as support for IBM and non-IBM hardware, operating systems, and application programs; network setup and configuration; upgraded or extended hardware repair services; and custom installations. Service availability and service name might vary by country or region.
For more information about these services, contact your IBM marketing representative.
Appendix A. Warranty information 39
Page 52
IBM Statement of Limited Warranty Z125-4753-06 8/2000 Part 1 - General Terms
This Statement of Limited Warranty includes Part 1 - General Terms and Part 2 ­Country-unique Terms. The terms of Part 2 replace or modify those of Part 1. The warranties provided by IBM in this Statement of Limited Warranty apply only to Machines you purchase for your use, and not for resale, from IBM or your reseller. The term Machinemeans an IBM machine, its features, conversions, upgrades, elements, or accessories, or any combination of them. The term Machinedoes not include any software programs, whether pre-loaded with the Machine, installed subsequently or otherwise. Unless IBM specifies otherwise, the following warranties apply only in the country where you acquire the Machine. Nothing in this Statement of Limited Warranty affects any statutory rights of consumers that cannot be waived or limited by contract. If you have any questions, contact IBM or your reseller.
The IBM Warranty for Machines: IBM warrants that each Machine 1) is free from defects in materials and workmanship and 2) conforms to IBMs Official Published Specifications (Specifications). The warranty period for a Machine is a specified, fixed period commencing on its Date of Installation. The date on your sales receipt is the Date of Installation unless IBM or your reseller informs you otherwise.
If a Machine does not function as warranted during the warranty period, and IBM or your reseller are unable to either 1) make it do so or 2) replace it with one that is at least functionally equivalent, you may return it to your place of purchase and your money will be refunded.
Extent of Warranty: The warranty does not cover the repair or exchange of a Machine resulting from misuse, accident, modification, unsuitable physical or operating environment, improper maintenance by you, or failure caused by a product for which IBM is not responsible. The warranty is voided by removal or alteration of Machine or parts identification labels.
THESE WARRANTIES ARE YOUR EXCLUSIVE WARRANTIES AND REPLACE ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF EXPRESS OR IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU. IN THAT EVENT, SUCH WARRANTIES ARE LIMITED IN DURATION TO THE WARRANTY PERIOD. NO WARRANTIES APPLY AFTER THAT PERIOD.
Items Not Covered by Warranty: IBM does not warrant uninterrupted or error-free
operation of a Machine. Any technical or other support provided for a Machine under warranty, such as assistance via telephone with how-toquestions and those regarding Machine set-up and installation, will be provided WITHOUT
WARRANTIES OF ANY KIND. Warranty Service: To obtain warranty service for a Machine, contact IBM or your
reseller. If you do not register your Machine with IBM, you may be required to present proof of purchase.
40 IBM xSeries 345 Type 8670: Installation Guide
Page 53
During the warranty period, IBM or your reseller, if approved by IBM to provide warranty service, provides without charge certain types of repair and exchange service to keep Machines in, or restore them to, conformance with their Specifications. IBM or your reseller will inform you of the available types of service for a Machine based on its country of installation. At its discretion, IBM or your reseller will 1) either repair or exchange the failing Machine and 2) provide the service either at your location or a service center. IBM or your reseller will also manage and install selected engineering changes that apply to the Machine.
Some parts of IBM Machines are designated as Customer Replaceable Units (called CRUs), e.g., keyboards, memory, or hard disk drives. IBM ships CRUs to you for replacement by you. You must return all defective CRUs to IBM within 30 days of your receipt of the replacement CRU. You are responsible for downloading designated Machine Code and Licensed Internal Code updates from an IBM Internet Web site or from other electronic media, and following the instructions that IBM provides.
When warranty service involves the exchange of a Machine or part, the item IBM or your reseller replaces becomes its property and the replacement becomes yours. You represent that all removed items are genuine and unaltered. The replacement may not be new, but will be in good working order and at least functionally equivalent to the item replaced. The replacement assumes the warranty service status of the replaced item. Many features, conversions, or upgrades involve the removal of parts and their return to IBM. A part that replaces a removed part will assume the warranty service status of the removed part.
Before IBM or your reseller exchanges a Machine or part, you agree to remove all features, parts, options, alterations, and attachments not under warranty service.
You also agree to
1. ensure that the Machine is free of any legal obligations or restrictions that prevent its exchange;
2. obtain authorization from the owner to have IBM or your reseller service a Machine that you do not own; and
3. where applicable, before service is provided: a. follow the problem determination, problem analysis, and service request
procedures that IBM or your reseller provides; b. secure all programs, data, and funds contained in a Machine; c. provide IBM or your reseller with sufficient, free, and safe access to your
facilities to permit them to fulfill their obligations; and
d. inform IBM or your reseller of changes in a Machines location.
IBM is responsible for loss of, or damage to, your Machine while it is 1) in IBMs possession or 2) in transit in those cases where IBM is responsible for the transportation charges.
Neither IBM nor your reseller is responsible for any of your confidential, proprietary or personal information contained in a Machine which you return to IBM or your reseller for any reason. You should remove all such information from the Machine prior to its return.
Limitation of Liability: Circumstances may arise where, because of a default on IBMs part or other liability, you are entitled to recover damages from IBM. In each such instance, regardless of the basis on which you are entitled to claim damages from IBM (including fundamental breach, negligence, misrepresentation, or other
Appendix A. Warranty information 41
Page 54
contract or tort claim), except for any liability that cannot be waived or limited by applicable laws, IBM is liable for no more than
1. damages for bodily injury (including death) and damage to real property and tangible personal property; and
2. the amount of any other actual direct damages, up to the charges (if recurring, 12 monthscharges apply) for the Machine that is subject of the claim. For purposes of this item, the term Machineincludes Machine Code and Licensed Internal Code.
This limit also applies to IBMs suppliers and your reseller. It is the maximum for which IBM, its suppliers, and your reseller are collectively responsible.
UNDER NO CIRCUMSTANCES IS IBM LIABLE FOR ANY OF THE FOLLOWING:
1) THIRD-PARTY CLAIMS AGAINST YOU FOR DAMAGES (OTHER THAN
THOSE UNDER THE FIRST ITEM LISTED ABOVE); 2) LOSS OF, OR DAMAGE TO, YOUR RECORDS OR DATA; OR 3) SPECIAL, INCIDENTAL, OR INDIRECT DAMAGES OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST SAVINGS, EVEN IF IBM, ITS SUPPLIERS OR YOUR RESELLER IS INFORMED OF THEIR POSSIBILITY. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
Governing Law: Both you and IBM consent to the application of the laws of the
country in which you acquired the Machine to govern, interpret, and enforce all of your and IBMs rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Agreement, without regard to conflict of law principles.
Part 2 - Country-unique Terms
AMERICAS
BRAZIL Governing Law: The following is added after the first sentence:Any litigation arising
from this Agreement will be settled exclusively by the court of Rio de Janeiro.
NORTH AMERICA Warranty Service: The following is added to this Section: To obtain warranty
service from IBM in Canada or the United States, call 1-800-IBM-SERV (426-7378).
CANADA Governing Law: The following replaces laws of the country in which you acquired
the Machinein the first sentence: laws in the Province of Ontario.
UNITED STATES Governing Law: The following replaces laws of the country in which you acquired
the Machinein the first sentence: laws of the State of New York.
ASIA PACIFIC
AUSTRALIA
42 IBM xSeries 345 Type 8670: Installation Guide
Page 55
The IBM Warranty for Machines: The following paragraph is added to this Section:
The warranties specified in this Section are in addition to any rights you may have under the Trade Practices Act 1974 or other similar legislation and are only limited to the extent permitted by the applicable legislation.
Limitation of Liability: The following is added to this Section: Where IBM is in breach of a condition or warranty implied by the Trade Practices Act 1974 or other similar legislation, IBMs liability is limited to the repair or replacement of the goods or the supply of equivalent goods. Where that condition or warranty relates to right to sell, quiet possession or clear title, or the goods are of a kind ordinarily acquired for personal, domestic or household use or consumption, then none of the limitations in this paragraph apply.
Governing Law: The following replaces laws of the country in which you acquired the Machinein the first sentence: laws of the State or Territory.
CAMBODIA, LAOS, AND VIETNAM Governing Law: The following replaces laws of the country in which you acquired
the Machinein the first sentence:laws of the State of New York. The following is added to this Section: Disputes and differences arising out of or in
connection with this Agreement shall be finally settled by arbitration which shall be held in Singapore in accordance with the rules of the International Chamber of Commerce (ICC). The arbitrator or arbitrators designated in conformity with those rules shall have the power to rule on their own competence and on the validity of the Agreement to submit to arbitration. The arbitration award shall be final and binding for the parties without appeal and the arbitral award shall be in writing and set forth the findings of fact and the conclusions of law.
All proceedings shall be conducted, including all documents presented in such proceedings, in the English language. The number of arbitrators shall be three, with each side to the dispute being entitled to appoint one arbitrator.
The two arbitrators appointed by the parties shall appoint a third arbitrator before proceeding upon the reference. The third arbitrator shall act as chairman of the proceedings. Vacancies in the post of chairman shall be filled by the president of the ICC. Other vacancies shall be filled by the respective nominating party. Proceedings shall continue from the stage they were at when the vacancy occurred.
If one of the parties refuses or otherwise fails to appoint an arbitrator within 30 days of the date the other party appoints its, the first appointed arbitrator shall be the sole arbitrator, provided that the arbitrator was validly and properly appointed.
The English language version of this Agreement prevails over any other language version.
HONG KONG AND MACAU Governing Law: The following replaces laws of the country in which you acquired
the Machinein the first sentence: laws of Hong Kong Special Administrative Region.
INDIA Limitation of Liability: The following replaces items 1 and 2 of this Section:
Appendix A. Warranty information 43
Page 56
1. liability for bodily injury (including death) or damage to real property and tangible personal property will be limited to that caused by IBMs negligence;
2. as to any other actual damage arising in any situation involving nonperformance by IBM pursuant to, or in any way related to the subject of this Statement of Limited Warranty, IBMs liability will be limited to the charge paid by you for the individual Machine that is the subject of the claim.
JAPAN Governing Law: The following sentence is added to this Section:Any doubts
concerning this Agreement will be initially resolved between us in good faith and in accordance with the principle of mutual trust.
NEW ZEALAND The IBM Warranty for Machines: The following paragraph is added to this Section:
The warranties specified in this Section are in addition to any rights you may have under the Consumer Guarantees Act 1993 or other legislation which cannot be excluded or limited. The Consumer Guarantees Act 1993 will not apply in respect of any goods which IBM provides, if you require the goods for the purposes of a business as defined in that Act.
Limitation of Liability: The following is added to this Section: Where Machines are not acquired for the purposes of a business as defined in the Consumer Guarantees Act 1993, the limitations in this Section are subject to the limitations in that Act.
PEOPLES REPUBLIC OF CHINA (PRC) Governing Law: The following replaces this Section: Both you and IBM consent to
the application of the laws of the State of New York (except when local law requires otherwise) to govern, interpret, and enforce all your and IBMs rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Agreement, without regard to conflict of law principles.
Any disputes arising from or in connection with this Agreement will first be resolved by friendly negotiations, failing which either of us has the right to submit the dispute to the China International Economic and Trade Arbitration Commission in Beijing, the PRC, for arbitration in accordance with its arbitration rules in force at the time. The arbitration tribunal will consist of three arbitrators. The language to be used therein will be English and Chinese. An arbitral award will be final and binding on all the parties, and will be enforceable under the Convention on the Recognition and Enforcement of Foreign Arbitral Awards (1958).
The arbitration fee will be borne by the losing party unless otherwise determined by the arbitral award.
During the course of arbitration, this Agreement will continue to be performed except for the part which the parties are disputing and which is undergoing arbitration.
EUROPE, MIDDLE EAST, AFRICA (EMEA)
THE FOLLOWING TERMS APPLY TO ALL EMEA COUNTRIES: The terms of this Statement of Limited Warranty apply to Machines purchased from IBM or an IBM reseller.
44 IBM xSeries 345 Type 8670: Installation Guide
Page 57
Warranty Service: If you purchase an IBM Machine in Austria, Belgium, Denmark, Estonia, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland or United Kingdom, you may obtain warranty service for that Machine in any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM. If you purchase an IBM Personal Computer Machine in Albania, Armenia, Belarus, Bosnia and Herzegovina, Bulgaria, Croatia, Czech Republic, Georgia, Hungary, Kazakhstan, Kirghizia, Federal Republic of Yugoslavia, Former Yugoslav Republic of Macedonia (FYROM), Moldova, Poland, Romania, Russia, Slovak Republic, Slovenia, or Ukraine, you may obtain warranty service for that Machine in any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM.
If you purchase an IBM Machine in a Middle Eastern or African country, you may obtain warranty service for that Machine from the IBM entity within the country of purchase, if that IBM entity provides warranty service in that country, or from an IBM reseller, approved by IBM to perform warranty service on that Machine in that country. Warranty service in Africa is available within 50 kilometers of an IBM authorized service provider. You are responsible for transportation costs for Machines located outside 50 kilometers of an IBM authorized service provider.
Governing Law: The applicable laws that govern, interpret and enforce rights, duties, and obligations of each of us arising from, or relating in any manner to, the subject matter of this Statement, without regard to conflict of laws principles, as well as Country-unique terms and competent court for this Statement are those of the country in which the warranty service is being provided, except that in 1) Albania, Bosnia-Herzegovina, Bulgaria, Croatia, Hungary, Former Yugoslav Republic of Macedonia, Romania, Slovakia, Slovenia, Armenia, Azerbaijan, Belarus, Georgia, Kazakhstan, Kyrgyzstan, Moldova, Russia, Tajikistan, Turkmenistan, Ukraine, and Uzbekistan, the laws of Austria apply; 2) Estonia, Latvia, and Lithuania, the laws of Finland apply; 3) Algeria, Benin, Burkina Faso, Cameroon, Cape Verde, Central African Republic, Chad, Congo, Djibouti, Democratic Republic of Congo, Equatorial Guinea, France, Gabon, Gambia, Guinea, Guinea-Bissau, Ivory Coast, Lebanon, Mali, Mauritania, Morocco, Niger, Senegal, Togo, and Tunisia, this Agreement will be construed and the legal relations between the parties will be determined in accordance with the French laws and all disputes arising out of this Agreement or related to its violation or execution, including summary proceedings, will be settled exclusively by the Commercial Court of Paris; 4) Angola, Bahrain, Botswana, Burundi, Egypt, Eritrea, Ethiopia, Ghana, Jordan, Kenya, Kuwait, Liberia, Malawi, Malta, Mozambique, Nigeria, Oman, Pakistan, Qatar, Rwanda, Sao Tome, Saudi Arabia, Sierra Leone, Somalia, Tanzania, Uganda, United Arab Emirates, United Kingdom, West Bank/Gaza, Yemen, Zambia, and Zimbabwe, this Agreement will be governed by English Law and disputes relating to it will be submitted to the exclusive jurisdiction of the English courts; and 5) in Greece, Israel, Italy, Portugal, and Spain any legal claim arising out of this Statement will be brought before, and finally settled by, the competent court of Athens, Tel Aviv, Milan, Lisbon, and Madrid, respectively.
THE FOLLOWING TERMS APPLY TO THE COUNTRY SPECIFIED:
AUSTRIA AND GERMANY The IBM Warranty for Machines: The following replaces the first sentence of the
first paragraph of this Section: The warranty for an IBM Machine covers the functionality of the Machine for its normal use and the Machines conformity to its Specifications.
Appendix A. Warranty information 45
Page 58
The following paragraphs are added to this Section:
The minimum warranty period for Machines is six months. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
Extent of Warranty: The second paragraph does not apply. Warranty Service: The following is added to this Section: During the warranty
period, transportation for delivery of the failing Machine to IBM will be at IBMs expense.
Limitation of Liability: The following paragraph is added to this Section: The limitations and exclusions specified in the Statement of Limited Warranty will not apply to damages caused by IBM with fraud or gross negligence and for express warranty.
The following sentence is added to the end of item 2: IBMs liability under this item is limited to the violation of essential contractual terms in cases of ordinary negligence.
EGYPT Limitation of Liability: The following replaces item 2 in this Section: as to any
other actual direct damages, IBMs liability will be limited to the total amount you paid for the Machine that is the subject of the claim. For purposes of this item, the term Machineincludes Machine Code and Licensed Internal Code.
Applicability of suppliers and resellers (unchanged).
FRANCE Limitation of Liability: The following replaces the second sentence of the first
paragraph of this Section:In such instances, regardless of the basis on which you are entitled to claim damages from IBM, IBM is liable for no more than: (items 1 and 2 unchanged).
IRELAND Extent of Warranty: The following is added to this Section: Except as expressly
provided in these terms and conditions, all statutory conditions, including all warranties implied, but without prejudice to the generality of the foregoing all warranties implied by the Sale of Goods Act 1893 or the Sale of Goods and Supply of Services Act 1980 are hereby excluded.
Limitation of Liability: The following replaces items one and two of the first paragraph of this Section:1. death or personal injury or physical damage to your
real property solely caused by IBMs negligence; and 2. the amount of any other actual direct damages, up to 125 percent of the charges (if recurring, the 12 monthscharges apply) for the Machine that is the subject of the claim or which otherwise gives rise to the claim.
Applicability of suppliers and resellers (unchanged).
46 IBM xSeries 345 Type 8670: Installation Guide
Page 59
The following paragraph is added at the end of this Section: IBMs entire liability and your sole remedy, whether in contract or in tort, in respect of any default shall be limited to damages.
ITALY Limitation of Liability: The following replaces the second sentence in the first
paragraph:In each such instance unless otherwise provided by mandatory law, IBM is liable for no more than: 1. (unchanged) 2. as to any other actual damage arising in all situations involving nonperformance by IBM pursuant to, or in any way related to the subject matter of this Statement of Warranty, IBMs liability, will be limited to the total amount you paid for the Machine that is the subject of the claim.
Applicability of suppliers and resellers (unchanged). The following replaces the third paragraph of this Section: Unless otherwise
provided by mandatory law, IBM and your reseller are not liable for any of the following: (items 1 and 2 unchanged) 3) indirect damages, even if IBM or your reseller is informed of their possibility.
SOUTH AFRICA, NAMIBIA, BOTSWANA, LESOTHO AND SWAZILAND Limitation of Liability: The following is added to this Section: IBMs entire liability
to you for actual damages arising in all situations involving nonperformance by IBM in respect of the subject matter of this Statement of Warranty will be limited to the charge paid by you for the individual Machine that is the subject of your claim from IBM.
UNITED KINGDOM Limitation of Liability: The following replaces items 1 and 2 of the first paragraph
of this Section:
1. death or personal injury or physical damage to your real property solely caused by IBMs negligence;
2. the amount of any other actual direct damages or loss, up to 125 percent of the charges (if recurring, the 12 monthscharges apply) for the Machine that is the subject of the claim or which otherwise gives rise to the claim;
The following item is added to this paragraph: 3. breach of IBMs obligations implied by Section 12 of the Sale of Goods Act 1979 or Section 2 of the Supply of Goods and Services Act 1982.
Applicability of suppliers and resellers (unchanged). The following is added to the end of this Section: IBMs entire liability and your sole
remedy, whether in contract or in tort, in respect of any default shall be limited to damages.
Appendix A. Warranty information 47
Page 60
48 IBM xSeries 345 Type 8670: Installation Guide
Page 61
Appendix B. Notices
This publication was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the users responsibility to evaluate and verify the operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A.
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS ISWITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
Edition notice
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
Any references in this publication to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
© COPYRIGHT INTERNATIONAL BUSINESS MACHINES CORPORATION, 2002. All rights reserved.
Note to U.S. Government Users Documentation related to restricted rights Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corp.
© Copyright IBM Corp. 2002 49
Page 62
Trademarks
The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both:
Active Memory PS/2 Active PCI ServeRAID Active PCI-X ServerGuide Alert on LAN ServerProven C2T Inteconnect TechConnect Chipkill ThinkPad EtherJet Tivoli e-business logo Tivoli Enterprise FlashCopy Update Connector IBM Wake on LAN IntelliStation XA-32 Light Path Diagnostics XA-64 NetBAY X-Architecture Netfinity XceL4 NetView XpandOnDemand Netvista xSeries OS/2 WARP Predictive Failure Analysis
Lotus and Domino are trademarks of Lotus Development Corporation and/or IBM Corporation in the United States, other countries, or both.
Important notes
Intel, Celeron, MMX, LANDesk, Pentium, Pentium II Xeon, Pentium III Xeon, and Xeon are trademarks of Intel Corporation in the United States, other countries, or both.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other countries.
Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
Linux is a registered trademark of Linus Torvalds. Other company, product, or service names may be the trademarks or service marks
of others.
Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance.
CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum possible.
50 IBM xSeries 345 Type 8670: Installation Guide
Page 63
When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately 1000 bytes, MB stands for approximately 1000000 bytes, and GB stands for approximately 1000000000 bytes.
When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM.
Maximum memory may require replacement of the standard memory with an optional memory module.
IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties.
Unless otherwise stated, IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM.
Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
Electronic emission notices Federal Communications Commission (FCC) statement
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the users authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Appendix B. Notices 51
Page 64
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformitéàla réglementation dIndustrie Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Australia and New Zealand Class A statement
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
United Kingdom telecommunications safety requirement
Notice to Customers
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect connection to public telecommunication systems in the United Kingdom.
European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards.
This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN
55022. The Limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.
Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Taiwan electrical emission statement
52 IBM xSeries 345 Type 8670: Installation Guide
Page 65
Japanese Voluntary Control Council for Interference (VCCI) statement
Power cords
For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
IBM power cords used in the United States and Canada are listed by Underwriters Laboratories (UL) and certified by the Canadian Standards Association (CSA).
For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15 amperes, 125 volts.
For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a tandem blade, grounding-type attachment plug rated 15 amperes, 250 volts.
For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with a grounding-type attachment plug. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed.
IBM power cords for a specific country or region are usually available only in that country or region.
Table 7. Power cords
IBM power cord part number
13F9940 Argentina, Australia, China (PRC), New Zealand, Papua New
13F9979 Afghanistan, Algeria, Andorra, Angola, Austria, Belgium, Benin,
13F9997 Denmark 14F0015 Bangladesh, Burma, Pakistan, South Africa, Sri Lanka
Used in these countries and regions
Guinea, Paraguay, Uruguay, Western Samoa
Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep., Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guinea, Hungary, Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, Zimbabwe
Appendix B. Notices 53
Page 66
Table 7. Power cords (continued)
IBM power cord part number
14F0033 Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong
14F0051 Liechtenstein, Switzerland 14F0069 Chile, Ethiopia, Italy, Libya, Somalia 14F0087 Israel 1838574 Thailand 6952301 Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman
Used in these countries and regions
S.A.R.), Cyprus, Dubai, Fiji, Ghana, India, Iraq, Ireland, Kenya, Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, United Kingdom, Yemen, Zambia
Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indies), United States of America, Venezuela
54 IBM xSeries 345 Type 8670: Installation Guide
Page 67
Index A
AC power LED 19 acoustical noise emissions 2 adapter
considerations 6 expansion slot locations 6 installing
non-hot-plug 7 ServeRAID-5i 6
slot locations 6 PCI bus, identification 6 PCI riser card assembly 7 requirements 6 retention bracket 4 specifications 2 system requirements 6
air baffle
microprocessor 4 power supply 4 removing 14
air-baffle assembly
illustration 4
B
bay identification, hot-swap drives 11 beep codes 27
C
cable
connectors 17 routing 17
cabling
external 17 the server 17
CD-eject button 19 CD-ROM
problems 30
CD-ROM drive
activity LED 19 eject buton 19 specifications 2
Class A electronic emission notice 51 completing the installation 17 components
major 4
configuration
Configuration/Setup Utility 23 integrated RAID controller 24 LSI Logic Configuration Utility 23 ServeRAID programs 23 ServerGuide Setup and Installation CD 23
Configuration/Setup Utility program 23 configuring your server 23 connectors
adapter 6
connectors (continued)
cable 18 DIMMs 10 external 18 front 18 microprocessor 12 rear 18 VRM 12
cooling 2
D
DC power LED 19 DIMM
See memory module
diskette drive
activity LED 19 problem 30
specifications 2 display problems 31 drive
hot-swap
installing 11
internal 11
E
eject button
CD 19
diskette 19 electrical input 2 electrical safety information viii electronic emission Class A notice 51 environment 2 error messages
POST 28 Ethernet activity LED 21 Ethernet-link status link LED 20, 21 expansion
enclosure problems 30 external
cabling 17
F
FCC Class A notice 51 features
server 2 filler panel, hard disk drive bay 11
H
handling static sensitive devices 6 hard disk drive LED
activity 20 hard disk drive status LED 20 heat output 2
© Copyright IBM Corp. 2002 55
Page 68
hot-swap and hot-plug devices
drives 4, 11 fans 4 power supplies 16
hot-swap drive
bay identification 11 installing 11 specifications 2
hot-swap power supply
installing 16
I
IBM Director 23 indicators 19 information label 1 information LED 19, 20 information panel 19 installation order
memory modules 10
installing
hot-swap drive 11 hot-swap power supply 16 memory module 9 microprocessor 12 non-hot-plug adapter 7
VRM 14 integrated RAID controller 6 intermittent problems 31
K
keyboard
problems 31
L
LEDs
AC power 19
DC power 19
Ethernet activity 21
Ethernet-link status 20, 21
front view 19
hard disk drive activity 20
hard disk drive status 20
information 20
rear view 20
system identification 20 LSI Logic Configuration Utility
description 25
starting 25 LSI Logic Configuration Utility program 25
M
major components 4 memory
problems 31
specifications 2
Web site 9
memory module
installing 9 order of installation 10 specifications 2 supported 9
microprocessor
air baffle 13 heat sink 15 installing 12 problem 31 specifications 2
VRM 14 monitor problems 31 mouse
problems 31
N
notes, important 50 notices
electronic emission 51
FCC, Class A 51
used in this book 3
O
operator panel 19 option
installation 5
problems 32 order of installation
memory modules 10
P
PCI
bus A 6
bus B 6
bus C 6 PCI expansion slots 2 PCI riser-card assembly
adapter installation 8
illustration 4
retention latch 8 pointing device
problems 31 POST error messages 28 power
problems 33 power cords 53 power supply
installing 16
operating requirements 16
specifications 2 power-control button 19 power-control button shield 21 power-on LED 19 problems
CD-ROM drive 30
diskette drive 30
expansion enclosure 30
56 IBM xSeries 345 Type 8670: Installation Guide
Page 69
problems (continued)
intermittent 31 keyboard 31 memory 31 microprocessor 31 monitor 31 mouse 31 option 32 pointing device 31 power 33 serial port 33 software 33 USB port 33
problems, solving 27
R
rack installation considerations 17 rack, installing your server in 17 reset button 19 retention latch 8
S
safety information
electrical vii, viii laser viii lifting viii
SCSI
adapter boot option 6
serial port
problems 33 server installation considerations 17 ServeRAID Manager
overview 24
starting 24 ServeRAID programs 23 ServeRAID-5i
configuring 24 ServeRAID-5i controller
considerations 6
installation 6 ServerGuide
error symptoms 29
Setup and Installation CD 23 shield
power-control button 21 shutting down the server 22 size 2
software
problems 33 solving problems 27 specifications 2 starting the server 21 static electricity 6 status LEDs 20 stopping the server 22 system error LED 19 system identification LED 20 system reliability 5
T
temperature 2 thermal material
heat sink 15 top cover 4 trademarks 50 troubleshooting chart 30 turning off the server 22 turning on the server 21
U
United States electronic emission Class A notice 51 United States FCC Class A notice 51 Universal Serial Bus (USB)
problems 33
V
video 2 video controller 2 voltage regulator module
installing 14 VRM See voltage regulator module 14
W
Web site
compatible options 5
DIMM specifications 10
X-Architecture 1 weight 2 working inside server with power on 5 World Wide Web 1
Index 57
Page 70
Page 71
IBM
Part Number: 48P9726
Printed in the United States of America
48P9714