ERserver
xSeries 306
Type 8836
Option Installation Guide

ER s e r v e r
xSeries 306
Type 8836
Option Installation Guide

©
US
NOTE:
Before using this information and the product it supports, read the general information in “Notices,” on
page 23.
First Edition (April 2004)
Copyright International Business Machines Corporation 2004. All rights reserved.
Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.

©
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . .1
Related documentation . . . . . . . . . . . . . . . . . . . . . .1
Notices and statements used in this book . . . . . . . . . . . . . . .2
Major components of the xSeries 306 Type 8836 . . . . . . . . . . . . .3
System-board internal connectors . . . . . . . . . . . . . . . . . .4
System-board switches and jumpers . . . . . . . . . . . . . . . . .4
System-board external connectors . . . . . . . . . . . . . . . . . .5
System-board LEDs . . . . . . . . . . . . . . . . . . . . . . .5
System-board option connectors . . . . . . . . . . . . . . . . . . .6
Chapter 2. Installing options . . . . . . . . . . . . . . . . . . . .7
Installation guidelines . . . . . . . . . . . . . . . . . . . . . . .7
System reliability guidelines . . . . . . . . . . . . . . . . . . . .7
Handling static-sensitive devices . . . . . . . . . . . . . . . . . .7
Server power features . . . . . . . . . . . . . . . . . . . . . . .8
Turning on the server . . . . . . . . . . . . . . . . . . . . . .8
Turning off the server . . . . . . . . . . . . . . . . . . . . . .8
Removing the cover . . . . . . . . . . . . . . . . . . . . . . .9
Installing an adapter . . . . . . . . . . . . . . . . . . . . . . .10
Installing a hard disk drive . . . . . . . . . . . . . . . . . . . . .12
Installing a simple-swap Serial ATA hard disk drive . . . . . . . . . . .13
Installing a SCSI hard disk drive . . . . . . . . . . . . . . . . .14
Installing a memory module . . . . . . . . . . . . . . . . . . . .15
Replacing a fan assembly . . . . . . . . . . . . . . . . . . . . .16
Replacing the battery . . . . . . . . . . . . . . . . . . . . . .17
Completing the installation . . . . . . . . . . . . . . . . . . . . .18
Installing the cover . . . . . . . . . . . . . . . . . . . . . .19
Connecting the cables . . . . . . . . . . . . . . . . . . . . .19
Updating the server configuration . . . . . . . . . . . . . . . . .20
Copyright IBM Corp. 2004
Chapter 3. Input/output ports and connectors . . . . . . . . . . . .21
Auxiliary-device connector . . . . . . . . . . . . . . . . . . . . .21
Ethernet connectors . . . . . . . . . . . . . . . . . . . . . . .21
Keyboard connector . . . . . . . . . . . . . . . . . . . . . . .22
Serial connector . . . . . . . . . . . . . . . . . . . . . . . .22
Universal Serial Bus connectors . . . . . . . . . . . . . . . . . .22
Video connector . . . . . . . . . . . . . . . . . . . . . . . .22
Appendix. Notices . . . . . . . . . . . . . . . . . . . . . . .23
Edition notice . . . . . . . . . . . . . . . . . . . . . . . . .23
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . .24
Important notes . . . . . . . . . . . . . . . . . . . . . . . . .24
Product recycling and disposal . . . . . . . . . . . . . . . . . . .25
Battery return program . . . . . . . . . . . . . . . . . . . . . .25
Electronic emission notices . . . . . . . . . . . . . . . . . . . .26
Federal Communications Commission (FCC) statement . . . . . . . . .26
Industry Canada Class A emission compliance statement . . . . . . . .26
Australia and New Zealand Class A statement . . . . . . . . . . . .26
United Kingdom telecommunications safety requirement . . . . . . . . .26
European Union EMC Directive conformance statement . . . . . . . . .27
Taiwanese Class A warning statement . . . . . . . . . . . . . . .27
iii

iv
Chinese Class A warning statement . . . . . . . . . . . . . . . .27
Japanese Voluntary Control Council for Interference (VCCI) statement . . .27
Power cords . . . . . . . . . . . . . . . . . . . . . . . . . .28
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
xSeries 306 Type 8836: Option Installation Guide

©
Safety
Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt.
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Avant d’installer ce produit, lisez les consignes de sécurité.
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
Copyright IBM Corp. 2004
v

vi
Antes de instalar este producto, lea la información de seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
xSeries 306 Type 8836: Option Installation Guide

Be
To
v Do
v
v
v
v
v
v
To
To
1.
2.
3.
4.
5.
1.
2.
3.
4.
Important:
All caution and danger statements in this documentation begin with a number. This
number is used to cross reference an English caution or danger statement with
translated versions of the caution or danger statement in the IBM Safety Information
book.
For example, if a caution statement begins with a number 1, translations for that
caution statement appear in the IBM Safety Information book under statement 1.
sure to read all caution and danger statements in this documentation before
performing the instructions. Read any additional safety information that comes with
your server or optional device before you install the device.
Statement 1:
DANGER
Electrical
current from power, telephone, and communication cables is
hazardous.
avoid a shock hazard:
not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
Connect all power cords to a properly wired and grounded electrical
outlet.
Connect to properly wired outlets any equipment that will be attached to
this product.
When possible, use one hand only to connect or disconnect signal
cables.
Never turn on any equipment when there is evidence of fire, water, or
structural damage.
Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached
devices.
Connect:
Turn everything OFF.
First, attach all cables to devices.
Attach signal cables to connectors.
Attach power cords to outlet.
Turn device ON.
Disconnect:
Turn everything OFF.
First, remove power cords from outlet.
Remove signal cables from connectors.
Remove all cables from devices.
Safety
vii

a
Do
v
v
v
of
v Do
v
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
not:
Throw or immerse into water
Heat to more than 100°C (212°F)
Repair or disassemble
Dispose
the battery as required by local ordinances or regulations.
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
Some
laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly
with optical instruments, and avoid direct exposure to the beam.
viii
xSeries 306 Type 8836: Option Installation Guide

≥ 18 kg
≥ 32 kg
≥ 55 kg
Statement 4:
(39.7 lb)
(70.5 lb)
(121.2 lb)
CAUTION:
Use safe practices when lifting.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
Safety
ix

a
x
Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
service technician.
xSeries 306 Type 8836: Option Installation Guide

In
v
v
v
v
v
to
1. Go to
2. In
3. On
4. In
5.
©
Chapter 1. Introduction
This Option Installation Guide contains instructions for installing, removing, and
connecting optional devices that your server supports.
Related documentation
addition to this Option Installation Guide, the following documentation comes with
your server:
User’s Guide
This document is in Portable Document Format (PDF) on the IBM
Documentation CD. It contains general information about your server, including
information about features, how to configure the server, and how to get help.
Installation Guide
This printed document contains instructions for setting up your server and basic
instructions for installing some options.
Safety Information
This document is in PDF on the IBM xSeries Documentation CD. It contains
translated caution and danger statements. Each caution and danger statement
that appears in the documentation has a number that you can use to locate the
corresponding statement in your language in the Safety Information document.
Rack Installation Instructions
This printed document contains instructions for installing your server in a rack.
Hardware Maintenance Manual and Troubleshooting Guide
This document is in PDF on the IBM xSeries Documentation CD. It contains
information to help you solve problems yourself, and it contains information for
service technicians.
®
xSeries
®
Depending on your server model, additional documentation might be included on
the IBM xSeries Documentation CD.
Your server might have features that are not described in the documentation that
you received with the server. The documentation might be updated occasionally to
include information about those features, or technical updates might be available to
provide additional information that is not included in your server documentation.
These updates are available from the IBM Web site. Complete the following steps
check for updated documentation and technical updates:
http://www.ibm.com/pc/support/.
the Learn section, click Online publications.
the “Online publications” page, in the Brand field, select Servers.
the Family field, select xSeries 306.
Click Continue.
Copyright IBM Corp. 2004
1

v
v
v
v
to
v
2
Notices and statements used in this book
The caution and danger statements that appear in this document are also in the
multilingual Safety Information document, which is on the IBM xSeries
Documentation CD. Each statement is numbered for reference to the corresponding
statement in the Safety Information document.
The following notices and statements are used in this document:
Note: These notices provide important tips, guidance, or advice.
Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
Attention: These notices indicate possible damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
Caution: These statements indicate situations that can be potentially hazardous
you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
xSeries 306 Type 8836: Option Installation Guide

Major components of the xSeries 306 Type 8836
Blue on a component indicates touch points, where you can grip the component to
remove it from or install it in the server, open or close a latch, and so on.
Orange on a component or an orange label on or near a component indicates that
the component can be hot-swapped, which means that if the server and operating
system support hot-swap capability, you can remove or install the component while
the server is running. (Orange can also indicate touch points on hot-swap
components.) See the instructions for removing or installing a specific hot-swap
component for any additional procedures that you might have to perform before you
remove or install the component.
The following illustration shows the major components in the server.
Captive screw
CD-ROM drive
SCSI hard disk
drive (some models)
Bezel
Fans
Heat sink
Riser-card
assembly
Power supply
DIMM
System board
Diskette drive
Chapter 1. Introduction
3

4
System-board internal connectors
The following illustration shows the internal connectors on the system board.
SCSI LED connector
Remote Supervisor
Adapter connector
Fan 1
connector
Wake-on-LAN
connector
USB operator
panel connector
Primary IDE
connector
SATA connectors
Operator information
panel connector
Powe r
connector
Microprocessor
power cable connector
Diskette drive
signal connector
Microprocessor
socket
Fan 3 connector
Fan 4 connector
Fan 2 connector
System-board switches and jumpers
The following illustration shows the switches and jumpers on the system board.
NMI switch
Clear CMOS jumper (JP2)
Boot block recovery jumper (JP1)
xSeries 306 Type 8836: Option Installation Guide

System-board external connectors
The following illustration shows the external connectors on the system board.
Keyboard/mouse connector
Serial connector
Video connector
Ethernet 1/USB connector
Ethernet 2 connector
System-board LEDs
The following illustration shows the light-emitting diodes (LEDs) on the system
board.
Standby
power LED
Fan 1
error LED
DIMM 4
error LED
DIMM 3
error LED
DIMM 2
error LED
DIMM 1
error LED
Fan 3
error LED
Fan 4
error LED
Fan 2
error LED
Chapter 1. Introduction
5

6
System-board option connectors
The following illustration shows the connectors for user-installable options.
Battery
connector
PCI-X riser
card connector
DIMM 1 slot
DIMM 2 slot
DIMM 3 slot
DIMM 4 slot
The following illustration shows the location of the PCI-X slots on the riser-card
assembly.
PCI-X slot 1
64-bit 3.3 V 66 MHz
PCI-X slot 2
64-bit 3.3 V 66 MHz
xSeries 306 Type 8836: Option Installation Guide

v
v
v
v
v
v
v
v
To
v
v
v
v
To
To
v
v
v Do
©
Chapter 2. Installing options
This chapter provides detailed instructions for installing hardware options in your
server.
Installation guidelines
Before you begin installing options in your server, read the following information:
Read the safety information beginning on page v and the guidelines in “Handling
static-sensitive devices” on page 7. This information will help you work safely
with your server and options.
Make sure that you have an adequate number of properly grounded electrical
outlets for your server, monitor, and other devices that you will connect to the
server.
Back up all important data before you make changes to disk drives.
Have a small flat-blade screwdriver available.
You do not have to turn off the server to install or replace hot-plug Universal
Serial Bus (USB) devices.
Blue on a component indicates touch points, were you can grip the component to
remove it from or install it in the server, open or close a latch, and so on.
Orange on a component or an orange label on or near a component indicates
that the component can be hot-swapped, which means that if the server and
operating system support hot-swap capability, you can remove or install the
component while the server is running. (Orange can also indicate touch points on
hot-swap components.) See the instructions for removing or installing a specific
hot-swap component for any additional procedures that you might have to
perform before you remove or install the component.
For a list of supported options for your server, go to
http://www.ibm.com/pc/compat/.
System reliability guidelines
help ensure proper cooling and system reliability, make sure that:
Each of the drive bays has a drive tray installed in it.
There is adequate space around the server to allow the server cooling system to
work properly. Leave approximately 50 mm (2.0 in.) of open space around the
front and rear of the server. Do not place objects in front of the fans.
You have followed the cabling instructions that come with optional adapters.
You have replaced a failed fan within 48 hours.
Handling static-sensitive devices
Attention: Static electricity can damage electronic devices, including your server.
avoid damage, keep static-sensitive devices in their static-protective packages
until you are ready to install them.
reduce the possibility of damage from electrostatic discharge, observe the
following precautions:
Limit your movement. Movement can cause static electricity to build up around
you.
Handle the device carefully, holding it by its edges or its frame.
not touch solder joints, pins, or exposed circuitry.
Copyright IBM Corp. 2004
7

Do
v
v
a
v
v If a
v If
v If
v If
on
8
v
not leave the device where others can handle and damage it.
While the device is still in its static-protective package, touch it to an unpainted
metal part of the server for at least 2 seconds. This drains static electricity from
the package and from your body.
Remove the device from its package and install it directly into the server without
setting down the device. If it is necessary to set down the device, put it back into
its static-protective package. Do not place the device on your server cover or on
metal surface.
Take additional care when handling devices during cold weather. Heating reduces
indoor humidity and increases static electricity.
Server power features
When the server is connected to an ac power source but is not turned on, the
operating system does not run, and all core logic except for the service processor is
shut down; however, the server can respond to requests from the service processor,
such as a remote request to turn on the server. The power-on LED flashes to
indicate that the server is connected to ac power but is not turned on.
Turning on the server
Approximately 20 seconds after the server is connected to ac power, the
power-control button becomes active, and you can turn on the server and start the
operating system by pressing the power-control button. The server can also be
turned on in any of the following ways:
power failure occurs while the server is turned on, the server will restart
automatically when power is restored.
the server is connected to an Advanced System Management interconnect
network that contains at least one server with an optional Remote Supervisor
Adapter II installed, the server can be turned on from the Remote Supervisor
Adapter II user interface.
your operating system supports the system-management software for an
optional Remote Supervisor Adapter II, the system-management software can
turn on the server.
your operating system supports the Wake on LAN
feature can turn on the server.
Note:
memory is reserved for various system resources and is unavailable to the
operating system. The amount of memory that is reserved for system resources
depends on the operating system, the configuration of the server, and the
configured PCI options.
When 4 GB or more of memory (physical or logical) is installed, some
®
feature, the Wake on LAN
Turning off the server
When you turn off the server and leave it connected to ac power, the server can
respond to requests from the service processor, such as a remote request to turn
the server. To remove all power from the server, you must disconnect it from the
power source.
Some operating systems require an orderly shutdown before you turn off the server.
See your operating-system documentation for information about shutting down the
operating system.
xSeries 306 Type 8836: Option Installation Guide

v
v
v If
v If
v If an
v If
v
1.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
The server can be turned off in any of the following ways:
You can turn off the server from the operating system, if your operating system
supports this feature. After an orderly shutdown of the operating system, the
server will be turned off automatically.
You can press the power-control button to start an orderly shutdown of the
operating system and turn off the server, if your operating system supports this
feature.
the operating system stops functioning, you can press and hold the
power-control button for more than 4 seconds to turn off the server.
the server is connected to an Advanced System Management interconnect
network that contains at least one server with an optional Remote Supervisor
Adapter II installed, the server can be turned off from the Remote Supervisor
Adapter II user interface.
can be turned off from the Remote Supervisor Adapter II user interface.
the Wake on LAN feature turned on the server, the Wake on LAN feature can
turn off the server.
You can turn off the server through a request from the service processor.
Removing the cover
Complete the following steps to remove the cover:
Read the safety information beginning on page v and “Installation guidelines” on
page 7.
optional Remote Supervisor Adapter II is installed in the server, the server
Chapter 2. Installing options
9

3.
4.
5.
v
v
v
v
v
v
v
v
v
v
1.
10
2.
Turn off the server and all attached devices (see “Turning off the server” on
page 8).
Captive screw
Disconnect all external cables and the power cord.
Loosen the captive screw on the rear of the cover.
Slide the cover back and off the server.
Installing an adapter
The following notes describe the types of adapters that your server supports and
other information that you must consider when installing an adapter:
Locate the documentation that comes with the adapter and follow those
instructions in addition to the instructions in this section. If you need to change
the switch settings or jumper settings on the adapter, follow the instructions that
come with the adapter.
Your server comes with two peripheral component interconnect-extended (PCI-X)
adapter slots located on the riser-card assembly. You must first remove the
riser-card assembly to access the PCI-X connectors.
There are two 64-bit 66 MHz PCI-X slots.
You can install one low profile half-length adapter in expansion slot 1 and one
full-height three-quarter-length adapter in expansion slot 2.
Your server supports 3.3 V or universal adapters.
Your server uses a rotational interrupt technique to configure PCI-X adapters so
that you can install PCI-X adapters that do not support sharing of PCI-X
interrupts.
The server scans PCI-X slots to assign system resources. If you have not
changed the default startup sequence, the server starts devices in the following
order: the CD-ROM and diskette drives first; then, PCI-X slot 2, PCI-X slot 1, and
the integrated Ethernet controllers.
The optional Remote Supervisor Adapter II can be installed only in PCI-X slot 2.
You can install an optional RAID controller in your server to control the internal
hard disk drives, for example, to enable you to configure the internal hard disk
drives into disk arrays. See your RAID controller option documentation for
complete instructions on installing a RAID controller in your server and for
additional information on RAID controllers.
The optional ServeRAID
The low-profile bracket that comes with the controller is required to install the
controller.
™
-7t S-ATA controller can be installed only in PCI-X slot
xSeries 306 Type 8836: Option Installation Guide

v No
1.
on
2.
3.
4.
v
The optional ServeRAID-6i+ controller can be installed only in PCI-X slot 1. The
low-profile bracket that comes with the controller is required to install the
controller.
rerouting of the internal SCSI cable (SCSI models only) is required if you are
installing the ServeRAID-6i+ controller. The ServeRAID-6i+ controller uses the
SCSI connector (SCSI models only) for output.
Complete
Riser-card
assembly
PCI-X riser card
connector
the following steps to install an adapter.
PCI-X slots
Adapter support
bracket
Adapter
Read the safety information beginning on page v and “Installation guidelines”
page 7.
Turn off the server and peripheral devices, and disconnect the power cord and
all external cables. Remove the cover (see “Removing the cover” on page 9).
Follow the cabling instructions, if any, that come with the adapter. Route the
adapter cables before you install the adapter.
Follow the instructions that come with the adapter to set jumpers or switches, if
any.
Chapter 2. Installing options
11

6.
7.
8.
9. To
If
v
v
12
5.
Loosen the captive screw on the rear of the server and remove the riser-card
assembly. Place the riser-card assembly on a flat, static-protective surface.
Expansion slot
cover (slot 1)
Expansion slot
cover (slot 2)
Riser-card
assembly
Captive screw
Remove the expansion-slot cover.
Attention: PCI expansion-slot covers must be installed on all vacant slots.
This maintains the electronic emissions characteristics of the server and
ensures proper cooling of server components.
Touch the static-protective package containing the adapter to any unpainted
metal surface on the server. Then, remove the adapter from the
static-protective package. Avoid touching the components and gold-edge
connectors on the adapter.
Place the adapter, component side up, on a flat, static-protective surface and
set any jumpers or switches as described by the adapter manufacturer, if
necessary.
Attention: When you install an adapter, make sure that it is completely and
correctly seated in the PCI expansion slot before you turn on the server.
Incomplete insertion might cause damage to the system board or the adapter.
install the adapter in the riser-card assembly, carefully grasp the adapter by
its top edge or upper corners, and align it with the PCI-X expansion slot; then,
press the adapter firmly into the expansion slot.
10.
Reinstall the riser-card assembly. Make sure that the riser-card assembly is
fully seated in the riser-card connector on the system board.
11.
Tighten the captive screw on the rear of the server.
you have other options to install, do so now. Otherwise, go to “Completing the
installation” on page 18.
Installing a hard disk drive
The following notes describe the type of hard disk drive that your server supports
and other information that you must consider when installing a hard disk drive:
Locate the documentation that comes with the hard disk drive and follow those
instructions in addition to the instructions in this chapter.
The server comes with one integrated drive electronics (IDE) CD-ROM drive, one
1.44 MB diskette drive, and one serial advanced technology attachment (ATA) or
SCSI hard disk drive, depending on server model.
xSeries 306 Type 8836: Option Installation Guide

If
1.
2.
3.
4.
5.
If
v
you are installing a SCSI hard disk drive, see the documentation that comes
with your drive before installing it.
Installing a simple-swap Serial ATA hard disk drive
Complete the following steps to install a simple-swap Serial ATA hard disk drive.
Note: If you have only one hard disk drive, install it in the left drive bay.
SATA hard disk
drive connector
Hard disk drive
Read the safety information beginning on page v and “Installation guidelines” on
page 7.
Turn off the server and peripheral devices, and disconnect the power cord and
all external cables.
Press the release tabs on the bezel and pull the bezel away from the server.
Slide the drive into the server until the drive connects to the backplane.
Reinstall the bezel.
you have other options to install, do so now. Otherwise, go to “Completing the
installation” on page 18.
Chapter 2. Installing options
13

1.
2.
3.
4.
5.
6.
7.
8.
9.
14
Installing a SCSI hard disk drive
Complete the following steps to install a SCSI hard disk drive.
Note: If you have only one hard disk drive, install it in the left drive bay.
Hard disk drive
Screws
Drive tray
Screws
Read the safety information beginning on page v and “Installation guidelines” on
page 7.
Turn off the server and peripheral devices, and disconnect the power cord and
all external cables. Remove the cover (see “Removing the cover” on page 9).
Press the release tabs on the bezel and pull the bezel away from the server.
Slide the drive tray out of the server.
Position the drive on the drive tray.
Secure the drive using the screws that come with the option.
Slide the drive tray back into the server.
Connect the signal and power cables to the drive.
Reinstall the bezel.
xSeries 306 Type 8836: Option Installation Guide

v
GB of
v
v
v If
v
v
1.
2.
If you have other options to install, do so now. Otherwise, go to “Completing the
installation” on page 18.
Installing a memory module
The following notes describe the type of dual inline memory modules (DIMMs) that
your server supports and other information that you must consider when installing
DIMMs:
Your server supports 256 MB, 512 MB, and 1 GB DIMMs, for a maximum of 4
system memory. Go to the ServerProven
http://www.ibm/com/pc/compat for a list of memory modules you can use with
your server.
The amount of usable memory will be reduced depending on the system
configuration. A certain amount of memory must be reserved for system
resources. The BIOS will display the total amount of installed memory and the
amount of configured memory.
Your server comes with one 512 MB DIMM installed in DIMM connector 1. If your
system has one DIMM installed, when you install an additional DIMM, it must be
installed in DIMM connector 3, and must be the same size, speed, type, and
technology as the DIMM installed in DIMM connector 1. You can mix compatible
DIMMs from various manufacturers.
you install a second pair of DIMMs in DIMM connectors 2 and 4, they do not
have to be the same size, speed, type, and technology as the DIMMs installed in
DIMM connectors 1 and 3. However, the size, speed, type, and technology of the
DIMMs you install in DIMM connectors 2 and 4 must match each other.
Install only 2.5 V, 184-pin, double-data-rate (DDR), PC2700 or PC3200,
unbuffered synchronous dynamic random-access memory (SDRAM) with error
correcting code (ECC) DIMMs. These DIMMs must be compatible with the latest
PC2700 and PC3200 SDRAM unbuffered DIMM specification.
When you restart the server, the system displays a message indicating that the
memory configuration has changed.
®
list at
Complete the following steps to install a DIMM:
Read the safety information beginning on page v and “Installation guidelines” on
page 7.
Turn off the server and peripheral devices, and disconnect the power cord and
all external cables. Remove the cover (see “Removing the cover” on page 9).
DIMM 4
DIMM 3
Chapter 2. Installing options
15

3.
4.
5.
6.
is
If
1.
2.
3.
4.
a.
b.
5.
16
Attention: To avoid breaking the retaining clips or damaging the DIMM
connectors, open and close the clips gently.
Open the retaining clip on each end of the DIMM connector.
Touch the static-protective package containing the DIMM to any unpainted metal
surface on the server. Then, remove the DIMM from the package.
Turn the DIMM so that the DIMM keys align correctly with the slot.
Insert the DIMM into the connector by aligning the edges of the DIMM with the
slots at the ends of the DIMM connector. Firmly press the DIMM straight down
into the connector by applying pressure on both ends of the DIMM
simultaneously. The retaining clips snap into the locked position when the DIMM
firmly seated in the connector. If there is a gap between the DIMM and the
retaining clips, the DIMM has not been correctly inserted; open the retaining
clips, remove the DIMM, and then reinsert it.
you have other options to install, do so now. Otherwise, go to “Completing the
installation” on page 18.
Replacing a fan assembly
The server comes with four replaceable fans.
Complete the following steps to replace a fan assembly. Use this procedure to
replace any of the four replaceable fans.
Read the safety information beginning on page v and “Installation guidelines” on
page 7.
Turn off the server and peripheral devices, and disconnect the power cord and
all external cables. Remove the cover (see “Removing the cover” on page 9).
Determine which fan to replace by checking the LED at each fan; a lit LED
indicates the fan to replace.
Note: For more information about the LEDs, see the Hardware Maintenance
Manual and Troubleshooting Guide on the IBM xSeries Documentation CD.
Remove the fan from the server:
Disconnect the fan cable from the system board.
Lift the fan out of the server.
Fan 1
Fan 2
Fan 3
Fan 4
Position the replacement fan so that the airflow arrow on the side of the fan is
pointing toward the rear of the server.
xSeries 306 Type 8836: Option Installation Guide

6.
7.
If
To
a
Do
v
v
v
of
1.
2.
3.
4.
a.
b.
Note: Correct airflow is from the front to the rear of the server.
Install the replacement fan in the location from which you removed the failed
fan.
Connect the replacement fan cable to the system board.
you have other options to install, do so now. Otherwise, go to “Completing the
installation” on page 18.
Replacing the battery
When replacing the battery, you must replace it with a lithium battery of the same
type from the same manufacturer. To avoid possible danger, read and follow the
safety statement below.
order replacement batteries, call 1-800-772-2227 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada,
call your IBM reseller or IBM marketing representative.
Note: After you replace the battery, you must reconfigure your system and reset
the system date and time.
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
not:
Throw or immerse into water
Heat to more than 100°C (212°F)
Repair or disassemble
Dispose
the battery as required by local ordinances or regulations.
Complete the following steps to replace the battery:
Read the safety information beginning on page v and follow any special
handling and installation instructions supplied with the replacement battery.
Turn off the server and peripheral devices, and disconnect the power cord and
all external cables. Remove the cover (see “Removing the cover” on page 9).
Remove the riser-card assembly.
Remove the battery:
Press the battery release tab to release the battery from the socket.
Lift the battery out of the socket.
Chapter 2. Installing options
17

a.
b.
6.
7.
8.
9.
v
v
1.
2.
a
v
v Do
4.
18
5.
Insert the new battery:
Tilt the battery so that you can insert it into the socket.
Press down on the battery after you insert it into the socket.
Reinstall the riser-card assembly.
Reinstall the server cover.
Reconnect all external cables and the power cord; then, turn on the peripheral
devices and the server.
Start the Configuration/Setup Utility program and set configuration parameters.
Set the system date and time and the user (power-on) password.
Reconfigure your server.
Completing the installation
Complete the following steps to complete the installation:
Reinstall the cover. See “Installing the cover” on page 19 for more information.
Install the server in the rack cabinet. See the Rack Installation Instructions that
come with your server for detailed information about how to install the server in
rack cabinet.
Attention:
Install your server only in a rack cabinet with perforated doors.
not leave open space above or below an installed server in your rack
cabinet. To help prevent damage to server components, always install a filler
panel to cover the open space and to help ensure proper air circulation. See
the documentation that comes with your rack cabinet for more information.
Connect the cables and power cords. See “Connecting the cables” on page 19
3.
for more information.
Update the server configuration. See “Updating the server configuration” on
page 20 for more information.
Attention: For proper cooling and airflow, replace the server cover before or
shortly after turning on the server. Operating the server for extended periods of time
(more than 15 minutes) with the server cover removed might damage server
components.
xSeries 306 Type 8836: Option Installation Guide

To
1.
2.
3.
4. If
5.
to
Installing the cover
install the cover, place it into position and slide it forward.
captive screw.
Then, tighten the
Captive screw
Connecting the cables
The following illustrations show the locations of the input and output connectors on
the front and rear of your server.
Notes:
You must turn off the server before connecting or disconnecting cables from
your server.
See the documentation that comes with your external devices for additional
cabling instructions. It might be easier for you to route cables before you
connect the devices to the server.
Cable identifiers are printed on the cables that come with your server and
options. Use these identifiers to connect the cables to the correct connectors.
your server comes with an operating system installed, see the documentation
that comes with your software for additional cabling instructions.
There is one keyboard connector on the back of the server. Use this connector
connect the server to a keyboard or optional console switch. You can also
connect a USB keyboard to the server using one of the USB ports. After
installing a USB keyboard, you might need to use the Configuration/Setup Utility
program to enable keyboardless operation and prevent the POST error
message 301 from being displayed during startup. For detailed information
about this option and how to connect it to your server, see the documentation
that comes with the option. If your server cables and connector panel have
color-coded connections, match the color of the cable end with the color of the
connector. For example, match a blue cable end with a blue panel connector, a
red cable end with a red connector, and so on.
Front
USB connectors
Chapter 2. Installing options
19

If
If
20
Rear
Keyboard
connector
Mouse
connector
Ethernet 1 connector
Ethernet 2 connector
System power
connector
Serial
connector
Video
connector
Updating the server configuration
When you start the server for the first time after you add or remove an internal
option or external SCSI device, you might receive a message that the configuration
has changed. The Configuration/Setup Utility program starts automatically so that
you can save the new configuration settings. For more information, see the section
about configuring the server in the User’s Guide on the IBM xSeries Documentation
CD.
Some options have device drivers that you need to install. See the documentation
that comes with the device for information about installing any required device
drivers.
the server has a RAID configuration using the SCSI controller with integrated
RAID (SCSI models only) or the integrated Serial ATA controller with integrated
RAID and you have installed or removed a hard disk drive, you might have to
reconfigure your disk arrays. See the RAID documentation on the IBM
ServeRAID-7e (Adaptec HostRAID) Support CD for more information about
reconfiguring the disk arrays.
the server has an optional RAID adapter and you have installed or removed a
hard disk drive, see the documentation that comes with the RAID adapter for
information about reconfiguring the disk arrays.
USB connectors
For more information about configuring the integrated Gigabit Ethernet controllers,
see the User’s Guide.
xSeries 306 Type 8836: Option Installation Guide

v
v
v
v
v
v
©
Chapter 3. Input/output ports and connectors
Your server has the following input/output (I/O) connectors:
One auxiliary-device (pointing-device)
Two Ethernet
One keyboard
One serial
Four Universal Serial Bus (USB) (two front, two rear)
One video
following illustration shows the locations of these connectors on the front of the
The
server.
USB connectors
The following illustration shows the locations of these connectors on the rear of the
server.
Keyboard
connector
Serial
connector
The following sections describe these connectors.
Auxiliary-device connector
Use this connector to connect a mouse or other pointing device. The following
illustration shows an auxiliary-device connector.
Mouse
connector
Video
connector
Ethernet 1 connector
Ethernet 2 connector
USB connectors
6
4
1
2
5
3
Ethernet connectors
The following illustration shows an Ethernet connector.
Connect a Category 3, 4, or 5 unshielded twisted-pair cable to this connector. The
100BASE-TX/1000BASE-T Fast Ethernet standard requires Category 5 or higher
cabling.
Copyright IBM Corp. 2004
Activity LED
(green)
Link LED
(green)
8
1
21

If
If
22
For more information about the Ethernet controllers, see the User’s Guide.
Keyboard connector
Use this connector to connect a PS/2
following illustration shows a keyboard connector.
®
(non-USB) keyboard to the server. The
you attach a keyboard to this connector, USB ports and devices are disabled
during POST.
Serial connector
Use a serial connector to connect a serial device. The following illustration shows a
serial connector.
Universal Serial Bus connectors
Use a Universal Serial Bus (USB) connector to connect a USB device. USB
technology transfers data at up to 12 Mb per second (Mbps) with a maximum of
127 devices and a maximum signal distance of 5 meters (16 ft.) per segment. Using
Plug and Play technology, USB devices are configured automatically. The following
illustration shows a USB connector.
6
4
2
1
5
3
1
5
69
14
you connect a PS/2 (non-USB) keyboard to the keyboard connector, USB ports
and devices are disabled during POST.
Video connector
The integrated video controller provides the video connector. The connector is on
the rear of the server. The following illustration shows a video connector.
xSeries 306 Type 8836: Option Installation Guide
5
1
1115

OR
OF
©
©
Appendix. Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the
products and services currently available in your area. Any reference to an IBM
product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product,
program, or service that does not infringe any IBM intellectual property right may be
used instead. However, it is the user’s responsibility to evaluate and verify the
operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not give you any
license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
Edition notice
INTERNATIONAL
BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Some states do not allow disclaimer of express or
implied warranties in certain transactions, therefore, this statement may not apply to
you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. IBM may make improvements and/or
changes in the product(s) and/or the program(s) described in this publication at any
time without notice.
Any references in this information to non-IBM Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those
Web sites. The materials at those Web sites are not part of the materials for this
IBM product, and use of those Web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.
Copyright International Business Machines Corporation 2004. All rights
reserved.
U.S. Government Users Restricted Rights — Use, duplication, or disclosure
restricted by GSA ADP Schedule Contract with IBM Corp.
Copyright IBM Corp. 2004
23

in
24
Trademarks
The following terms are trademarks of International Business Machines Corporation
the United States, other countries, or both:
Active Memory
Predictive Failure
Analysis
Active PCI
Active PCI-X
Alert on LAN
BladeCenter
C2T Interconnect
Chipkill
EtherJet
e-business logo
Eserver
FlashCopy
IBM
IBM (logo)
IntelliStation
NetBAY
Netfinity
NetView
PS/2
ServeRAID
ServerGuide
ServerProven
TechConnect
ThinkPad
Tivoli
Tivoli Enterprise
Update Connector
Wake on LAN
XA-32
XA-64
X-Architecture
XceL4
XpandOnDemand
xSeries
OS/2 WARP
Lotus, Lotus Notes, SmartSuite, and Domino are trademarks of Lotus Development
Corporation and/or IBM Corporation in the United States, other countries, or both.
Important notes
Intel, MMX, and Pentium are trademarks of Intel Corporation in the United States,
other countries, or both.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in
the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other
countries.
Java and all Java-based trademarks and logos are trademarks or registered
trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
Adaptec and HostRAID are trademarks of Adaptec, Inc. in the United States, other
countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
Processor speeds indicate the internal clock speed of the microprocessor; other
factors also affect application performance.
CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often
less than the maximum possible.
xSeries 306 Type 8836: Option Installation Guide

KB
to
In
or
of
on
When referring to processor storage, real and virtual storage, or channel volume,
stands for approximately 1000 bytes, MB stands for approximately 1 000 000
bytes, and GB stands for approximately 1 000 000 000 bytes.
When referring to hard disk drive capacity or communications volume, MB stands
for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible
capacity may vary depending on operating environments.
Maximum internal hard disk drive capacities assume the replacement of any
standard hard disk drives and population of all hard disk drive bays with the largest
currently supported drives available from IBM.
Maximum memory may require replacement of the standard memory with an
optional memory module.
IBM makes no representation or warranties regarding non-IBM products and
services that are ServerProven, including but not limited to the implied warranties of
merchantability and fitness for a particular purpose. These products are offered and
warranted solely by third parties.
IBM makes no representations or warranties with respect to non-IBM products.
Support (if any) for the non-IBM products is provided by the third party, not IBM.
Some software may differ from its retail version (if available), and may not include
user manuals or all program functionality.
Product recycling and disposal
This unit contains materials such as circuit boards, cables, electromagnetic
compatibility gaskets, and connectors which may contain lead and copper/beryllium
alloys that require special handling and disposal at end of life. Before this unit is
disposed of, these materials must be removed and recycled or discarded according
applicable regulations. IBM offers product-return programs in several countries.
Information on product recycling offerings can be found on IBM’s Internet site at
http://www.ibm.com/ibm/environment/products/prp.shtml.
Battery return program
This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride,
lithium, or lithium ion battery. Consult your user manual or service manual for
specific battery information. The battery must be recycled or disposed of properly.
Recycling facilities may not be available in your area. For information on disposal of
batteries outside the United States, go to
http://www.ibm.com/ibm/environment/products/batteryrecycle.shtml or contact your
local waste disposal facility.
the United States, IBM has established a collection process for reuse, recycling,
proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal
hydride, and battery packs from IBM equipment. For information on proper disposal
these batteries, contact IBM at 1-800-426-4333. Have the IBM part number listed
the battery available prior to your call.
Appendix. Notices
25

26
In the Netherlands, the following applies.
Electronic emission notices
Federal Communications Commission (FCC) statement
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference, in which case the user will be required to correct the
interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to
meet FCC emission limits. IBM is not responsible for any radio or television
interference caused by using other than recommended cables and connectors or by
unauthorized changes or modifications to this equipment. Unauthorized changes or
modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Industry Canada Class A emission compliance statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d’Industrie Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
Australia and New Zealand Class A statement
Attention: This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
United Kingdom telecommunications safety requirement
Notice to Customers
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect
connection to public telecommunication systems in the United Kingdom.
xSeries 306 Type 8836: Option Installation Guide

European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council
Directive 89/336/EEC on the approximation of the laws of the Member States
relating to electromagnetic compatibility. IBM cannot accept responsibility for any
failure to satisfy the protection requirements resulting from a nonrecommended
modification of the product, including the fitting of non-IBM option cards.
This product has been tested and found to comply with the limits for Class A
Information Technology Equipment according to CISPR 22/European Standard EN
55022. The limits for Class A equipment were derived for commercial and industrial
environments to provide reasonable protection against interference with licensed
communication equipment.
Attention:
This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
Taiwanese Class A warning statement
Chinese Class A warning statement
Japanese Voluntary Control Council for Interference (VCCI) statement
Appendix. Notices
27

a
28
Power cords
For your safety, IBM provides a power cord with a grounded attachment plug to use
with this IBM product. To avoid electrical shock, always use the power cord and
plug with a properly grounded outlet.
IBM power cords used in the United States and Canada are listed by Underwriter’s
Laboratories (UL) and certified by the Canadian Standards Association (CSA).
For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified
cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord,
maximum of 15 feet in length and a parallel blade, grounding-type attachment
plug rated 15 amperes, 125 volts.
For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and
CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT,
three-conductor cord, a maximum of 15 feet in length and a tandem blade,
grounding-type attachment plug rated 15 amperes, 250 volts.
For units intended to be operated at 230 volts (outside the U.S.): Use a cord set
with a grounding-type attachment plug. The cord set should have the appropriate
safety approvals for the country in which the equipment will be installed.
IBM power cords for a specific country or region are usually available only in that
country or region.
IBM power cord part
number
02K0546
13F9940
13F9979
13F9997
14F0015
Used in these countries and regions
China
Australia, Fiji, Kiribati, Nauru, New Zealand, Papua New Guinea
Afghanistan, Albania, Algeria, Andorra, Angola, Armenia, Austria,
Azerbaijan, Belarus, Belgium, Benin, Bosnia and Herzegovina,
Bulgaria, Burkina Faso, Burundi, Cambodia, Cameroon, Cape
Verde, Central African Republic, Chad, Comoros, Congo
(Democratic Republic of), Congo (Republic of), Cote D’Ivoire
(Ivory Coast), Croatia (Republic of), Czech Republic, Dahomey,
Djibouti, Egypt, Equatorial Guinea, Eritrea, Estonia, Ethiopia,
Finland, France, French Guyana, French Polynesia, Germany,
Greece, Guadeloupe, Guinea, Guinea Bissau, Hungary, Iceland,
Indonesia, Iran, Kazakhstan, Kyrgyzstan, Laos (People’s
Democratic Republic of), Latvia, Lebanon, Lithuania, Luxembourg,
Macedonia (former Yugoslav Republic of), Madagascar, Mali,
Martinique, Mauritania, Mauritius, Mayotte, Moldova (Republic of),
Monaco, Mongolia, Morocco, Mozambique, Netherlands, New
Caledonia, Niger, Norway, Poland, Portugal, Reunion, Romania,
Russian Federation, Rwanda, Sao To me and Principe, Saudi
Arabia, Senegal, Serbia, Slovakia, Slovenia (Republic of),
Somalia, Spain, Suriname, Sweden, Syrian Arab Republic,
Tajikistan, Tahiti, Togo, Tunisia, Turkey, Turkmenistan, Ukraine,
Upper Volta, Uzbekistan, Vanuatu, Vietnam, Wallis and Futuna,
Yugoslavia (Federal Republic of), Zaire
Denmark
Bangladesh, Lesotho, Maceo, Maldives, Namibia, Nepal,
Pakistan, Samoa, South Africa, Sri Lanka, Swaziland, Uganda
xSeries 306 Type 8836: Option Installation Guide

IBM power cord part
number
14F0033
Used in these countries and regions
Abu Dhabi, Bahrain, Botswana, Brunei Darussalam, Channel
Islands, China (Hong Kong S.A.R.), Cyprus, Dominica, Gambia,
Ghana, Grenada, Iraq, Ireland, Jordan, Kenya, Kuwait, Liberia,
Malawi, Malaysia, Malta, Myanmar (Burma), Nigeria, Oman,
Polynesia, Qatar, Saint Kitts and Nevis, Saint Lucia, Saint Vincent
and the Grenadines, Seychelles, Sierra Leone, Singapore, Sudan,
Tanzania (United Republic of), Trinidad and Tobago, United Arab
Emirates (Dubai), United Kingdom, Yemen, Zambia, Zimbabwe
14F0051
14F0069
14F0087
1838574
Liechtenstein, Switzerland
Chile, Italy, Libyan Arab Jamahiriya
Israel
Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize,
Bermuda, Bolivia, Brazil, Caicos Islands, Canada, Cayman
Islands, Costa Rica, Colombia, Cuba, Dominican Republic,
Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras,
Jamaica, Japan, Mexico, Micronesia (Federal States of),
Netherlands Antilles, Nicaragua, Panama, Peru, Philippines,
Taiwan, United States of America, Venezuela
24P6858
34G0232
36L8880
49P2078
49P2110
6952300
Korea (Democratic People’s Republic of), Korea (Republic of)
Japan
Argentina, Paraguay, Uruguay
India
Brazil
Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize,
Bermuda, Bolivia, Caicos Islands, Canada, Cayman Islands,
Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, El
Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico,
Micronesia (Federal States of), Netherlands Antilles, Nicaragua,
Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan,
United States of America, Venezuela
Appendix. Notices
29

30
xSeries 306 Type 8836: Option Installation Guide

11
19
13
11
of
2
2
©
Index
A
adapter
installing
PCI-X bus 10
B
battery replacement 17
C
Class A electronic emission notice 26
cover
installing
removing 9
D
DIMMs
connector
locations 15
E
electronic emission Class A notice 26
F
fan, replacing 16
FCC Class A notice 26
H
hard disk drive
IDE
installing 13
SCSI 13
I
installation order, memory modules 15
installing
adapters
battery 17
cover 19
hard disk drive 13
internal connectors 4
N
notes, important 24
notices
attention
book 2
caution 2
danger 2
electronic emission 26
FCC, Class A 26
important 2
O
order of installation, memory modules 15
P
power cords 28
R
related documentation 1
S
shutting down the server 8
simple-swap Serial ATA hard disk drive 13
Standby mode 8
statements
attention
caution 2
danger 2
important 2
stopping the server 8
switches and jumpers 4
system board
internal
connectors 4
jumper blocks 4
switches and jumpers 4
T
trademarks 24
turning off the server 8
turning on the server 8
J
jumpers 4
M
memory module
order
Copyright IBM Corp. 2004
installation 15
U
United States electronic emission Class A notice 26
United States FCC Class A notice 26
31

32
xSeries 306 Type 8836: Option Installation Guide

Part Number: 59P6591
Printed in USA
(1P) P/N: 59P6591