ERserver
xSeries 306
Type 8836
User’s Guide

ER s e r v e r
xSeries 306
Type 8836
User’s Guide

©
US
Note:
Before using this information and the product it supports, be sure to read the general information in
Appendix B, “Notices,” on page 25.
First Edition (April 2004)
Copyright International Business Machines Corporation 2004. All rights reserved.
Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.

©
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
Chapter 1. Introducing the xSeries 306 Type 8836 server . . . . . . . .1
Related documentation . . . . . . . . . . . . . . . . . . . . . .1
Notices and statements used in this book . . . . . . . . . . . . . . .2
Features and specifications . . . . . . . . . . . . . . . . . . . . .3
What your server offers . . . . . . . . . . . . . . . . . . . . . .4
Reliability, availability, and serviceability features . . . . . . . . . . . . .5
IBM Director . . . . . . . . . . . . . . . . . . . . . . . . . .5
The UpdateXpress program . . . . . . . . . . . . . . . . . . . .6
Server controls, LEDs, and power . . . . . . . . . . . . . . . . . .7
Front view . . . . . . . . . . . . . . . . . . . . . . . . . .7
Rear view . . . . . . . . . . . . . . . . . . . . . . . . . .7
Server power features . . . . . . . . . . . . . . . . . . . . . .9
Chapter 2. Configuring the server . . . . . . . . . . . . . . . . .11
Using the ServerGuide Setup and Installation CD . . . . . . . . . . . .11
ServerGuide features . . . . . . . . . . . . . . . . . . . . .12
Setup and configuration overview . . . . . . . . . . . . . . . . .12
Typical operating-system installation . . . . . . . . . . . . . . . .13
Installing your operating system without ServerGuide . . . . . . . . . .13
Using the Configuration/Setup Utility program . . . . . . . . . . . . .13
Starting the Configuration/Setup Utility program . . . . . . . . . . . .14
Configuration/Setup Utility menu choices . . . . . . . . . . . . . .14
Passwords . . . . . . . . . . . . . . . . . . . . . . . . .16
Using the SCSISelect Utility program (SCSI models only) . . . . . . . . .18
Starting the SCSISelect Utility program . . . . . . . . . . . . . . .18
SCSISelect Utility menu choices . . . . . . . . . . . . . . . . .19
Using the Adaptec HostRAID configuration programs . . . . . . . . . . .19
Using the Adaptec RAID Configuration Utility programs (for Serial ATA
HostRAID) . . . . . . . . . . . . . . . . . . . . . . . . .20
Using the SCSISelect Utility program (for SCSI HostRAID) . . . . . . . .21
Configuring the Gigabit Ethernet controllers . . . . . . . . . . . . . .22
Appendix A. Getting help and technical assistance . . . . . . . . . .23
Before you call . . . . . . . . . . . . . . . . . . . . . . . . .23
Using the documentation . . . . . . . . . . . . . . . . . . . . .23
Getting help and information from the World Wide Web . . . . . . . . . .24
Software service and support . . . . . . . . . . . . . . . . . . .24
Hardware service and support . . . . . . . . . . . . . . . . . . .24
Appendix B. Notices . . . . . . . . . . . . . . . . . . . . . .25
Edition notice . . . . . . . . . . . . . . . . . . . . . . . . .25
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . .26
Important notes . . . . . . . . . . . . . . . . . . . . . . . . .26
Product recycling and disposal . . . . . . . . . . . . . . . . . . .27
Battery return program . . . . . . . . . . . . . . . . . . . . . .27
Electronic emission notices . . . . . . . . . . . . . . . . . . . .28
Federal Communications Commission (FCC) statement . . . . . . . . .28
Industry Canada Class A emission compliance statement . . . . . . . .28
Australia and New Zealand Class A statement . . . . . . . . . . . .28
United Kingdom telecommunications safety requirement . . . . . . . . .28
European Union EMC Directive conformance statement . . . . . . . . .29
Copyright IBM Corp. 2004
iii

iv
Taiwanese Class A warning statement . . . . . . . . . . . . . . .29
Chinese Class A warning statement . . . . . . . . . . . . . . . .29
Japanese Voluntary Control Council for Interference (VCCI) statement . . .29
Power cords . . . . . . . . . . . . . . . . . . . . . . . . . .30
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
xSeries 306 Type 8836: User’s Guide

©
Safety
Before installing this product, read the Safety Information.
Antes de instalar este produto, leia as Informações de Segurança.
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.
Læs sikkerhedsforskrifterne, før du installerer dette produkt.
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Avant d’installer ce produit, lisez les consignes de sécurité.
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.
Antes de instalar este produto, leia as Informações sobre Segurança.
Copyright IBM Corp. 2004
v

vi
Antes de instalar este producto, lea la información de seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
xSeries 306 Type 8836: User’s Guide

Be
To
v Do
v
v
v
v
v
v
To
To
1.
2.
3.
4.
5.
1.
2.
3.
4.
Important:
All caution and danger statements in this documentation begin with a number. This
number is used to cross reference an English caution or danger statement with
translated versions of the caution or danger statement in the IBM Safety Information
book.
For example, if a caution statement begins with a number 1, translations for that
caution statement appear in the IBM Safety Information book under statement 1.
sure to read all caution and danger statements in this documentation before
performing the instructions. Read any additional safety information that comes with
your server or optional device before you install the device.
Statement 1:
DANGER
Electrical
current from power, telephone, and communication cables is
hazardous.
avoid a shock hazard:
not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
Connect all power cords to a properly wired and grounded electrical
outlet.
Connect to properly wired outlets any equipment that will be attached to
this product.
When possible, use one hand only to connect or disconnect signal
cables.
Never turn on any equipment when there is evidence of fire, water, or
structural damage.
Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached
devices.
Connect:
Turn everything OFF.
First, attach all cables to devices.
Attach signal cables to connectors.
Attach power cords to outlet.
Turn device ON.
Disconnect:
Turn everything OFF.
First, remove power cords from outlet.
Remove signal cables from connectors.
Remove all cables from devices.
Safety
vii

a
Do
v
v
v
of
v Do
v
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
not:
Throw or immerse into water
Heat to more than 100°C (212°F)
Repair or disassemble
Dispose
the battery as required by local ordinances or regulations.
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
Some
laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly
with optical instruments, and avoid direct exposure to the beam.
viii
xSeries 306 Type 8836: User’s Guide

≥ 18 kg
≥ 32 kg
≥ 55 kg
Statement 4:
(39.7 lb)
(70.5 lb)
(121.2 lb)
CAUTION:
Use safe practices when lifting.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
Safety
ix

a
x
Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
service technician.
xSeries 306 Type 8836: User’s Guide

v
v
v
v
v
on
©
Chapter 1. Introducing the xSeries 306 Type 8836 server
The IBM
®
networking environments that require superior microprocessor performance, efficient
memory management, and flexibility.
Performance, ease of use, and reliability were key considerations in the design of
your server. These design features make it possible for you to customize the
system hardware to meet your business needs.
Your server comes with a limited warranty. For more information about the terms of
your warranty, see the warranty appendix in the Installation Guide.
Your server contains IBM Enterprise X-Architecture
increase performance and reliability. For more information, see “What your server
offers” on page 4 and “Reliability, availability, and serviceability features” on page 5.
You can obtain up-to-date information about your server and other IBM server
products at http://www.ibm.com/eserver/xseries/.
For service or assistance information, see Appendix A, “Getting help and technical
assistance,” on page 23.
Related documentation
This User’s Guide provides general information about your server, including
information about features, how to configure the server, and how to get help. In
addition to this User’s Guide, the following documentation comes with your server:
Installation Guide
This printed document contains instructions for setting up your server and basic
instructions for installing some options.
Option Installation Guide
This document is in Portable Document Format (PDF) on the IBM xSeries
Documentation CD. It contains detailed instructions for installing, removing, and
connecting optional devices that your server supports.
Safety Information
This document is in PDF on the IBM xSeries Documentation CD. It contains
translated caution and danger statements. Each caution and danger statement
that appears in the documentation has a number that you can use to locate the
corresponding statement in your language in the Safety Information document.
Rack Installation Instructions
This printed document contains instructions for installing your server in a rack.
Hardware Maintenance Manual and Troubleshooting Guide
This document is in PDF on the IBM xSeries Documentation CD. It contains
information to help you solve problems yourself, and it contains information for
service technicians.
Eserver
™
xSeries
®
306 Type 8836 server is ideally suited for
™
technologies, which help
Depending
the IBM xSeries Documentation CD.
Your server might have features that are not described in the documentation that
you received with the server. The documentation might be updated occasionally to
Copyright IBM Corp. 2004
your server model, additional documentation might be included on
1

to
1. Go to
2. In
3. On
4. In
5.
v
v
v
v
to
v
2
include information about those features, or technical updates might be available to
provide additional information that is not included in your server documentation.
These updates are available from the IBM Web site. Complete the following steps
check for updated documentation and technical updates:
http://www.ibm.com/pc/support/.
the Learn section, click Online publications.
the ″Online publications″ page, in the Brand field, select Servers.
the Family field, select xSeries 306.
Click Continue.
Notices and statements used in this book
The caution and danger statements that appear in this document are also in the
multilingual Safety Information document, which is on the IBM xSeries
Documentation CD. Each statement is numbered for reference to the corresponding
statement in the Safety Information document.
The following notices and statements are used in this document:
Notes: These notices provide important tips, guidance, or advice.
Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
Attention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
Caution: These statements indicate situations that can be potentially hazardous
you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
xSeries 306 Type 8836: User’s Guide

IV
v
v
v
v
v
1 GB
v
v
v
v
v 16 MB
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
–
to
–
–
–
v
v
v
v
–
–
–
–
–
–
1.
2.
Features and specifications
The following information is a summary of the features and specifications of your
server. Depending on your server model, some features might not be available, or
some specifications might not apply.
Table 1. Features and specifications
Microprocessor:
One Intel
™
Pentium
®
1024 KB
(minimum) Level-2 cache and MMX
(MMX2) technology
Note: Use the Configuration/Setup
Utility program to determine the type
and speed of the microprocessor in
your server.
Memory:
Minimum: 512 MB
Maximum: 4 GB
Type: PC2700/3200,
333/400 MHz, ECC, SDRAM,
registered DIMMs only
Slots: Four dual inline
Supports 256 MB, 512 MB, and
DIMMs
Drives:
Diskette: 1.44 MB
CD-ROM: IDE
Expansion
bays:
Two 3.5-inch slim-high bays for hard
disk drives
Expansion slots:
Two 66 MHz/64-bit PCI-X slots (one
low profile half-length, one full-height
three-quarter-length)
Video controller:
ATI Radeon 7000M IGP video on
system board
Compatible with SVGA and VGA
DDR-SDRAM video memory
Power
supply:
300 watt (110 or 220 V ac
auto-sensing)
Size:
Height: 43 mm (1.75 inches, 1 U)
Depth: 508 mm (20 inches)
™
Width: 430 mm (16.69 inches)
Maximum weight: 12.7 kg (28 lb)
depending on your configuration
Integrated
Dual 1000Base-T, 100Base-T,
10Base-T Ethernet controllers on
the system board with Wake on
LAN
Serial port
Four USB ports (two on front and
two on rear of server)
Keyboard port
Mouse port
ATA-100 single-channel IDE
controller
Hard
Serial ATA controller with
integrated RAID
Ultra320 SCSI controller with
integrated RAID (SCSI models)
Acoustical
Sound power, idling: 6.5 bel
maximum
Sound power, operating: 6.5 bel
maximum
Environment:
Air temperature:
v
Humidity:
functions:
®
support
disk controllers:
noise emissions:
Server on: 10° to 35°C (50.0°
95.0°F); altitude: 0 to 914 m
(2998.7 ft)
Server off: -40° to 60°C
(-104° to 140°F); maximum
altitude: 2133 m (6998.0 ft)
Server on: 8% to 80%
Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour:
Minimum configuration: 307 Btu (90
watts)
Maximum configuration: 850 Btu
(250 watts)
Electrical
input:
Sine-wave input (47-63 Hz) required
Input voltage low range:
Minimum: 100 V ac
Maximum: 127 V ac
v
Input voltage high range:
Minimum: 200 V ac
Maximum: 240 V ac
v
Input kilovolt-amperes (kVA),
approximately:
Minimum: 0.20 kVA
Maximum: 0.45 kVA
Notes:
Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in a given
location might exceed the average
values stated because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which a large number of computers
will operate.
Chapter 1. Introducing the xSeries 306 Type 8836 server
3