IBM 4QX, 42X, 200, 42E, 900 User Manual

...
Hardware Maintenance Manual
IBM PC Server/Enterprise Racks
IBM
Hardware Maintenance Manual
IBM PC Server/Enterprise Racks
IBM
Note:
Before using this info rm atio n and the produ ct it supp or ts , be sure to read th e gen era l information under “Notices” on page 195.
Sixth Edition (November 1999) Updated April 2001
The following paragraph does not apply to the United Kingdom or any country where such provisi ons are incons istent with local law :
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactio ns, th erefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program( s) described in this publication at any time.
This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other countries, and the information is subject to change without notice. Consult your local IBM representative for information on the products, services, and features available in your area.
Requests for technical information about IBM products sho uld be made to your IBM reseller or IBM marketing representative.
© Copyright International Business Machines C orporation 2001. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

About this supplement

This supplement contains diagnostic and service information for the IBM PC Server Rack Enclosure and the IBM Rack enclosures:
IBM PC Ser ver Rack Encl osure models:
Type 9306 19-inch and 24-inch Models:4QS, 4QX, 9QS9QX, 9TS, 9TX
IBM Rack enclosure models:Type 9306 Models 200, 900Type 9308 Models 42P, 42X, 42S, 42E, 4SA, 4SB (NetBAY42 Enterprise)
IBM NetBAY3 enclosure
IBM NetBAY3E enclosure
This supplement should be used with the related service information in the IBM PC Servers Hardwar e Ma intenance Manual (part number 70H0751, form number S30H­2501-01).
Important: This manual is intended for trained servicers who are familiar with IBM
PC Server and IBM Server products. Before servicing an IBM product, be sure to review Safety info rma tion
on page 183.

Related publicat ion s

The following publications are available for IBM products. For more information, contact IBM or an IBM Author ized Dealer.
© Copyright IBM Corp. 2001 iii
For information about See publication
PC Servers IBM PC Servers Hardware Maintenance Manual
(S30H-2501)
PS/2 Computers IBM Personal System/2 Hardware Maintenance
Manual (S52G-9971)
PS/ValuePoint Compute r s IBM PS/ValuePoint Hardware Maintenance Service
and Refere nce (S61G-1423)
Laptop, Notebook, Portable, and ThinkPad Computers (L40 , CL57, N45, N51, P70/P 75, ThinkPad 300, 350, 500, 510, 710T, Expansi on Unit, Dock I, Dock II)
ThinkPad Computers (Thi nkPad 340, 355, 360, 370, 700, 701, 720, 750, 755)
ThinkPad Computers (Thi nkPad 365,
760) Monitors (Disp l ays ) (February 199 3) IBM PS/2 Display HMM Volume 1 (SA38-0053 ) Monitors (December 1993) IBM Color Monitor HMM Volume 2 (S71G-4197) IBM Monitors (P Series) (February
1996) IBM 2248 Monitor (February 1996) IBM Monitor HMM Volume 4 (S52H-3739) Disk Array technology overview and
using the IBM RAID Configuration Program
Installation Planning for Personal System/2 computers
Ins tallati on Plan n i ng f o r A dvanc e d Personal System/2 Servers
IBM Mobile Systems Hardware Maintenance Manual Volume 1 (S82G-1501)
IBM Mobile Systems Hardware Maintenance Manual Volume 2 (S82G-1502)
IBM Mobile Systems Hardware Maintenance Manual Volume 3 (S82G-1503)
IBM Monitor HMM Volume 3 (S52H-3679)
Configuring Your Disk Array booklet (S82G-1506)
Personal Sy s tem/2 Installation Planning and Beyond (G41G-2927)
Advanced PS/2 Servers Planning and Selection Guide (GG24-3927)
iv Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
Contents
About this supplement . . . . . . . . . . . . . . . iii
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
IBM PC Server/Enterprise rack enclosures1
General checkout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Power checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Powering off the rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Type 9306 Models 4QS, 4QX, 9Q S, 9QX,
9TS, 9TX . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IBM PC Server expansion rack models. . . . . . . . . . . . 5
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Server selector console . . . . . . . . . . . . . . . . . . . . . . . . . 6
Server selector unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power distribution unit . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cooling fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Sliding trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sliding rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Keyboard tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Parts list i ng (Type 9306 – 19-inch) Model s 9QS, 9TS and
9QX, 9TX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Parts list i ng (Type 9306 – 24-inch) M odels 4QS, 4QX . 17
Type 9306 Model 200 . . . . . . . . . . . . . . . . . 21
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Selector switch locations. . . . . . . . . . . . . . . . . . . . . . . 22
Power Distribution Unit . . . . . . . . . . . . . . . . . . . . . . . 26
Blank bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fixed shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Keyboard tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Installing a flat panel monitor rack mount kit. . . . . 29
Removing the existing flat panel monitor stand. . . 29
Installing the new monitor stand. . . . . . . . . . . . . . . . 31
Starting the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Configuring the selector switch . . . . . . . . . . . . . . . . . 35
Switching among servers . . . . . . . . . . . . . . . . . . . . . . 36
Advanced selector switch functions . . . . . . . . . . . . . 37
Resetting the selector switch . . . . . . . . . . . . . . . . . . . 45
Making connections under power. . . . . . . . . . . . . . . 46
Parts Listing (Type 9306 Model 200). . . . . . . . . . . . . . . . 47
Attaching rack cabinets in a suite . . . . . . . . . . . . . . . 92
Installing L-channel support rails to rack mounting
brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Installing a server . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Fixed shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Keyboard tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Monitor shelf. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Installing a flat panel monitor rack mount kit. . . . 103
Removing the existing flat panel monitor stand. . 103
Installing the new monitor stand. . . . . . . . . . . . . . . 105
Blank filler panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Parts listing (Type 9308 Model 42P, 42X) . . . . . . . . . . . 111
NetBAY3 enclosure . . . . . . . . . . . . . . . . . 115
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 15
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Casters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Foot pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Front cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Device side rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Stacking NetBAY3 enclosures. . . . . . . . . . . . . . . . . . 118
Parts Listing (NetBAY3) . . . . . . . . . . . . . . . . . . . . . . . . . 121
NetBAY3E enclosure . . . . . . . . . . . . . . . . 123
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Casters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Front cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Device side rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Stacking NetBAY3E enclosures . . . . . . . . . . . . . . . . 126
Parts listing (NetBAY3E). . . . . . . . . . . . . . . . . . . . . . . . . 127
IBM NetBAY console switch . . . . . . . . . . 129
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Tool requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Installation overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Installing a console switch in a monitor shelf . . . . 132
Installing a console switch vertically in a rack. . . . 134
Installing a console switch horizontally in a rack . 137
Parts listing (NetBAY Console Switch). . . . . . . . . . . . . 139
Type 9306 Model 900/910 . . . . . . . . . . . . . 51
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Parts listing (Type 9306 Model 900/910) . . . . . . . . . . . . 77
NetBAY 42 Enterprise Rack (Type 9308
Models 42P, 42X, 4SA, 4SB, 42S, 42E). . 81
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Removing and installing panels . . . . . . . . . . . . . . . . 85
Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Removing and installing the top 6U portion of t he rack 91
Installing the stabilizer bracket . . . . . . . . . . . . . . . . . 92
© Copyright IBM Corp. 2001 v
NetBAY Power Distribution Units. . . . . . 141
NetBAY rack Power Distribution Unit introduction . 141
Tool requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Installation overview . . . . . . . . . . . . . . . . . . . . . . . . . 142
Installing devices vertically . . . . . . . . . . . . . . . . . . . 142
Installing a single device horizontally . . . . . . . . . . 144
Installing two devices horizontally . . . . . . . . . . . . . 146
Cabling your PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . 148
NetBAY front-end Power Distribution Unit introduction. 156
Tool requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Installation overview . . . . . . . . . . . . . . . . . . . . . . . . . 157
Installing a single device vertically . . . . . . . . . . . . . 157
Installing two devices vertically . . . . . . . . . . . . . . . 160
Rack PDU specifications . . . . . . . . . . . . . . . . . . . . . . 164
Line cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
NetBAY server dual-cord Power Distribution Unit
introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
Tool requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Installation overview. . . . . . . . . . . . . . . . . . . . . . . . . 167
Installing devices vertically . . . . . . . . . . . . . . . . . . . 167
Installing a single device horizontally . . . . . . . . . . 169
Installing two devices horizontally. . . . . . . . . . . . . 171
Cabling your PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Line cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Parts listing (Power Distribution Units) . . . . . . . . . . . 181
Related service information . . . . . . . . . . 183
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Safety notice (multi-lingual translations) . . . . . . . . 191
Safety inspection guide . . . . . . . . . . . . . . . . . . . . . . . 192
Handling electrostatic dischar ge-sensitive devices 193
Grounding requirements. . . . . . . . . . . . . . . . . . . . . . 194
Problem determination tips . . . . . . . . . . . . . . . . . . . . . . 194
Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Send us your comments! . . . . . . . . . . . . . . . . . . . . . . . . 196
Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
vi Hardware Maintenance Manual: IBM PC Server/Enterprise Racks

IBM PC Server/Enterprise rack encl osures

General checkout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Power checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General checkout

Use the following procedur e for diagnosing keyboard, mouse, and video pr oblems for the IBM PC Server Rack Enclosure and the IBM Rack enclosures (Type 9306 and Type
9308). For power problems, see Power checkout on page 2.
Attention:
For Models 4QS, 4QX, 9QS, 9QX, 9T S, 9TX only: Ensure that the voltage se lector switch on each server installed in the server rack
is set to 230 V ac.
For Models 200, 900 only: Ensure that the voltage se lector switch on each server installed in the server rack
is set to the proper voltage as supplied by the Power Distribution Unit, PDU.
1. Check the foll owing:
Ensure the external power cord is in good condition and properly connected
to a known-good power source.
Ensure the internal power cables are in good condition and properly
connected. (The internal power cables connect between the power distrib ution unit and the servers insta ll e d in the server rack.)
Ensure the following devices are power ed on.
a. Power distribution unit b. Server select or unit c. All system units d. Display
2. If the items/conditions specified in step 1. are not okay, correct the problem and verify that the server rack is operating correctly.
3. If the items/conditions specified in step 1. are okay, then, using the server selector keypad buttons, check the operation of the failing device for all of the servers that are installed in the rack.
4. Did the failure occur on more than one server?
NO: Go to the Hardware Mai ntenance manual for the serv e r th at was
selected when the failure occurred. Disconnect the keyboard an d mouse from the server selector unit and connect them directly to the failing server. Then, run the server diagnostic programs on the failing server.
If the problem still remains, disconnect the keyboard and mouse from the failing server and reconnect them to the server selector unit. Then, replace the server rack components in the following order until the problem goes away.
a. Device cable (connects between the server selector unit and the server
that was selected when the failure occurred).
Powering off the rack. . . . . . . . . . . . . . . . . . . . . . . . . 3
© Copyright IBM Corp. 2001 1

Power checkout

b. Server selector cable (connects between the server selector keypad and
the server selector unit). c. Server selector keypad. d. Server selector unit.
YES: Power-off the server rack and replace the server rack components in the
following order until the probl em goes away. See Powering off the rack on page 3.
a. Device extender cable (connects between the device and the server
selector unit) b. Failing device c. Server selector cable (connects between the server selector keypad and
the server selector unit) d. Server selector keyp ad e. Server selector unit
Use the following procedure for diagnosing power problems for the IBM PC Server Rack Enclosure and IBM Rack enclosure (Type 9306).
Attention:
For Models 4QS, 4QX, 9QS, 9QX, 9T S, 9TX only: Ensure that the voltage se lector switch on each server installed in the server rack
is set to 230 V ac.
For Models 200, 900 only: Ensure that the voltage se lector switch on each server installed in the server rack
is set to the proper voltage as supplied by the Power Distribution Unit, PDU.
1. Check the foll owing:
Ensure the external power cord is in good condition and properly connected
to a known-good power source.
Ensure the internal power cables are in good condition and properly
connected. (The internal power cables connect between the power distrib ution unit and the servers insta ll e d in the server rack.)
Ensure the following devices are power ed on.
a. Power distribution unit b. Server selector unit c. All system units d. Display
2. If the items/conditions in step 1. are not okay, correct the problem and verify correct operation of the server rack.
3. If the items/conditions specified in step 1. are okay, then, using the server selector keypad buttons, check for correct operatio n of all the serve rs installe d in the rack .
4. Did the failure occur on more than one server?
No: Go to the Hardware Maintenan ce manual for the ser ver that was sel ected
when the failure occurred and run the server diagnostic programs. If the problem still remains, replace the powe r distr ibut io n unit.
2 Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
Yes: Power-off the server rack and replace the server rack components in the

Powering off the rack

Before performing service on the rack, follow this procedure to prevent personal injury and to avoid damaging the rack and the installed servers.
To power-off the IBM PC Server Rack:
1. Shut down and power-off all installed servers.
2. Power-off the serve r selector unit.
3. If a UPS system is installed in the rack, power-off the UPS system.
4. Disconne ct p o wer from the IBM PC Server Rack.
If the rack is plugged into a wall-mounted power supply, disconnect the
If the power cord is wired directly into the installed location's power supply,
following order until the probl em goes away. See Powering off the rack on page 3.
a. Power distribution uni t fuse. b. Power distribution unit.
power cord plug from the wall socket.
open the rear door of t he rack cabinet and disconnect th e power plug from the base of the p o we r distri b uti o n u ni t .
IBM PC Server/Enterprise rack enclosures 3
4 Hardware Maintenance Manual: IBM PC Server/Enterprise Racks

Type 9306 Models 4QS, 4QX, 9QS, 9QX, 9TS, 9TX

Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IBM PC Server expansion rack models . . . . . . . . . . 5
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Server selector console . . . . . . . . . . . . . . . . . . . . . . . . 6
Server selector unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power distribution unit . . . . . . . . . . . . . . . . . . . . . . . 7
Cooling fan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Sliding trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Features

The 9306 IBM PC Server Rack E nclosure, models 4QS, 9QS, 9TS come i n thr ee primary models.
19-inch Quad Primary Server Rack, Model 9QS
19-inch Tri Primary Server Rack, Mode l 9TS
24-inch Quad Primary Server Rack, Model 4QS
A Quad Primary Server Rack can house up to four IBM PC Servers. The Tri Primary Server Rack can house up to three IBM PC Servers.
Both Quad and Tri Primary Server Racks provide a built in serv er selec tor wh ich connects to one set of cons ole devices (moni tor , keyboard, and mouse.) The se rver selector works independently from the server's operating systems, enabling the connected servers to run different operating systems.
Single latch rail tray . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dual latch rail tray . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Sliding rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Keyboard tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Parts listing (Type 9306 – 19-inch) Models 9QS, 9TS
and 9QX, 9TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Parts listing (Type 9306 – 24-inch) Models 4QS, 4QX 17

IBM PC Serv er expansio n rack models

Locations

These IBM 9306 PC Server Rack Enclosure models are shipped preassembled and pre­cabled.
Three optional IBM PC Server Rack Expansion models are available to expand the capacity of the IBM PC Server Rack Primary Enclosure. The optional IBM PC Server Rack Expansion models are:
19-inch Quad Expansio n Rac k, Model 9Q X
19-inch Tri Expansion R ack, Mo del 9TX
24-inch Quad Expansio n Rac k, Model 4Q X
The IBM PC Server Rack Ex p ansion m od els allo w th e instal lation of u p to four more servers using the Primary IBM PC Server Rack monitor, keyboard, and mouse.
The following sections contain information on specific equipment locations. Note: For instructi ons on how to power-off the rack, see Powering off the rack on
page 3.
© Copyright IBM Corp. 2001 5

Serve r sel ect or con so le

To remove the Server Selector Console:
1. Power-off th e rack.
2. Use an 1/8-inch allen wrench to remove screws.
3. Disconn e ct the server selector cable from the back of the server selector console.
4. Remove the server selector console from the cabinet.
Server
Monitor Bezel
Selector Console
Server Selector Keypad

Serve r sel ect or un it

The server selector unit is located in the upper rear of the rack cabinet. The server select or unit can only be acces s e d or remo v e d fro m the rea r of th e IB M Ra ck ca b in et.
CAUTION: The server selector unit is heavy. You will need two people to safely remove the server selector unit. See “Safety notice (multi-lingual translations)” on page 191.
To remove the server selector unit:
1. Power-off th e rack.
2. Unplug the keyboard, mouse, video cables, and the power cord.
3. Remove the ser ve r selector console.
4. With one person brac ing the server se lector unit f rom below, have the second person use a 5/16-inch wrench to remove the four nuts that secure the server selector unit to the rack cabinet.
5. Remove the server selector unit from the cabinet.
Note: When replac ing the ser ver sel ector unit , be sure t hat t he Server Sel ector ca ble is
fed throu gh the indentation along the lef t side of the server selector uni t.
Server Selector Electronics
Server Selector Cable
6 Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
Server Selector Cable

Connections

Server Rack Monitor Connection
AC Power
Input Server Monitor Connections
Server Selector Unit
Server Selector Unit On-Off Switch
M O N O
K B
O
Server Rack Keyboard Connection
G
G
A
A
2
1
M
K1M1K2M2K3M3K4M4K5M5K6M6K7M7K8M
O U
Server Rack Mouse Connection
G
G
A
A
4
3
Server Keyboard and Mouse Connections
V
V
V
V

Power distributi on unit

Note: For information and installa tion instructi ons for the IBM NetBAY Rack Power
Distribu tion Units, see Net BAY Power Distribution Units on page 141".
Note: To remove the power distribution unit, you might need to remove the right
side cabinet panel, the server installed in sliding tray 2 (in the primary IBM PC Server Rack), or sliding tray 5 (in the IBM PC Server Expansion Rack).
V
V
G
G
A
A
6
5
V
V
G
G
A
A
8
7
8
To remove the power distribution unit:
1. Power-off th e rack.
2. Disconnect all power plugs from the power distribution unit.
3. Using a Phillips screwdriver, remove the four screws from the front of the power distrib u tion unit.
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 7
Note: These screws ar e held in place by nuts and washers. Hold the nut while
you are unscrewing the screw to prevent the nut and washer from falling into the bottom of the cabinet.
4. Remove the po we r distribu tion unit from the cabinet.
AC Power Input
AC Fuse
Circuit Breaker
115V AC Power-On Indicator
Voltage Selection Switch
230V AC Power-On Indicator
AC Power Output

Cooling fan

To remove the cooling fan:
1. Power-off th e rack.
2. Open the rear door of the rack cab inet.
3. Disconnect the power plug from the rear of the cooling fan.
4. Use a 5/16-inch wrench to remove the eight nuts that secur e the cooling fan to the top of the ra ck cabine t.
5. Remove the cooling fan from the cabinet.
Note: When installing the fan, make sure that the green and yellow ground wire is
attached to one of the top fan mounting screws and that the strain-relieving clamp is attached to another. The power cable should be secured by the strain­relieving clamp.
8 Hardware Maintenance Manual: IBM PC Server/Enterprise Racks

Sliding trays

Models 4QS and 4QX come with either single latch slide rails or dual latch slide rails. Single latch slide rails have a front latch release on the right rail only. Dual latch slide rails have a front latch release on both rails. The slide rail FRU number for the 24-inch rack replaces the single latch slide rail with the dual latch slid e rail.
Note: If a server is installed on a tray being removed, first remove the server.
Single latch rail tray
To remove a sliding tray with single latch rails:
1. Power-off th e rack.
2. Open the rear door of the rack cabinet and remove the pin 1 that secures the slidin g tr ay to the cable manage me nt arm
3. Loosen the thumbscrews 2 on the sliding tray and fully extend the sliding tray.
4. Use a 3/32-inch allen wrench to remove the five screws 3 from the left side of the sliding tray.
5. Lift the rear locking tab 4 and push the sliding tray approximately two inches into the cabinet.
6. Release the forward locking tab 5. Then, while holding the sliding tray in place, use your other hand to grasp the outside sliding rail 6 and push it into the rack cabinet until it disconnects from the sliding tray.
Ground Wire
Power Plug
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 9
Dual latch rail tray
To remove a sliding tray with dual latch ra ils:
1. Power-off th e rack.
2. Open the rear door of the rack cabinet and remove the pin 1 that secures the slidi ng tray to the cable managemen t arm.
3. Loosen the thumbscrews 2 on the sliding tray and fully extend the sliding tray.
4. Push in on the spring of the right rear locking tab 3 and push the sliding tray approximately two inches into the cabinet.
5. Release both left and right forward locking tabs 4. Then, while holding the sliding tray in place, push bo th left and righ t ou tside sli ding rails 5 into the rack cabinet until it disconnects from the sliding tray.
Note: Left side view for 4 and 5 are not show n.

Sliding rails

This procedure is for single latch sliding rails and dual latch sliding rails. For single latch sliding rails, the right rail is the one that has the front latch. The left
rail doe s n o t h a ve a fron t l a tc h . For dual latch sliding rails, the right rail is the one that has the rear latch. The left rail
does not have a rear latch. To remove the sliding rails:
1. Power-off th e rack.
2. Remove the sliding tray that is attached to the sliding rails that you want to remove. See Sliding trays on page 9.
3. Use a 3/32-inch allen wrench to remove the four screws that secur e each of the sliding rails to the rack cabin et.
10 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Note: You will need to adjust the position of the sliding rail in order to line up the
access holes over the locations of the screws.

Keyboard tray

To remove the keyboard tray:
1. Power-off th e rack.
2. Disconnect the keyboard and mouse cables from the ke y board and mouse extension cables.
3. Remove the keyboard and mouse from the keyboard tray.
4. Pu ll the keybo a rd tray straig ht out of the ra ck cabine t.
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 11

Parts listing (Type 9306 – 19-inch) Models 9QS, 9TS and 9QX, 9TX

This parts listi ng is for Models 9QS, 9TS and 9QX, 9TX
4
8
6
5
3
7
9
10
11
27
28
1
26
2
30
29
24
23
19
20
22
25
21
18
17
13
12
14
15
16
12 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Index 19-Inch Rack Enclosure (Type 9306) FRU
1 Adapter Plate Options:
PS/2 Server 85 /95 76H3733 Model 300 76H3734
Model 500, 700 76H3734 2Monitor Stand 07H0061 3 Server Selector Cable 07H0036 4 Blank Bezel (9QX, 9TX Expansion units only) 76H0379 5 Monitor Bezel wit h button label 76H0378 6 Server Selector Keypad 07H0097 7 Monitor Housing (19-inch) 76H0377 8 Server Selector Unit Elect ronics
07H0034
See Safety inspection guide on page 192. 9 Internal Cables
06P6007
See Cable Kit Shelf Server
10 Cable Management Arm 76H0386 11 Cable Management Arm Single Server Tray 76H0387 12 Pin, Cable Manageme nt Arm 07H0089 13 Fan 220 V ac with Power Cord 07H0063 14 Latch, Rear Door 76H0376 15 Rear Door (19-Inch) 76H0373 15 Hinge Set for Rear Doo r 76H0389 16 External Powe r Cord:
Australia 14F1559
Europe 14F1554
Israel 14F1561
Italy 14F1560
New Zealand 14F1558
South America, India 14F1557
U.K./Denmark 14F1555
USA 14F1553
External Powe r Cord Option - 6 Ft. 07H0094
17 Left/Right Side Panel 76H0374 18 Caster 76H3626 19 NetBAY Rack Power Distribution Unit 09N9668 19 NetBAY Front-end Power Distribution Unit 09N9670
3-phase NEMA L21-30P line cord (200-250 Vac) for NetBAY Front-end PDU 00N7720
3-phase IEC 309 -3P+N+Gnd line co rd (380-415 Vac) for NetBAY Front-end PDU 00N7721
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 13
Index 19-Inch Rack Enclosure (Type 9306) FRU
1-phase NEMA L5-30P line cor d (100-127 Vac) for NetBAY Front-end PDU 00N7722 1-phase NEMA L6-30P line cor d (200-240 Vac) for NetBAY Front-end PDU 00N7723 1-phase IEC 309 -2P+Gnd line cord (200-240 Vac) for NetBAY Front-end PDU 00N7724
19 NetBAY Server Dual-cord Power Distribution Unit 09N9669
Hardware Kit for NetBAY Power Distri bution Units 09N9671
Power Distribution Unit 07H0424 19 250 V Slow Blow Fuse 0303549 20 Keyboard Sl ides, (one pair) 07H0038 21 Leveling Foot (Qty. 1) 76H0390 22 Stabilizing Bar 76H0375 23 Keyboard Tray, 19-Inch 76H0381 24 Slide Rails , Server Tray (one pair ) 07H0083 24 Slide Rails, Dual T r ay (one pair) 76H0383 25 19-inch Front Compartment Door (19-Inch by 26-Inch) Includes Hinge Set and Screws 76H0371 26 Door Hinge Set 76H0372 27 Door Valance (9QX, 9TX, Expansion units only) 76H0380 28 Mouse Table 07H0079 29 Dual Server Tray 76H0382 29 Dual Server Shelf 76H0385 30 Single Server Tray 76H0384
19-Inch Single Slide Shelf for an Industry Standard 19-Inch Rack. 76H3628
Cable, SVGA-Video (15 Feet) Opt i on 76H3736
Monitor Power Cabl e (connects from monitor to Power Dist ri bution Unit) 07H0075
Rack Keyboar d Cable (connects from Keyboard Drawer to Serv e r Sel e ctor Unit) 07H0067
Rack Mouse Cable (connects from Ke yboard Drawer to Serve r Se lector Unit) 07H0069
14 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Rack Enclosure Kits (Type 9306) FRU
Bolt-Together Kit (19-Inch to 24- Inch, 24-Inch to 19- Inch)
19-Inch Attachment Bracket (2 each)
Screw 1/4-20 x 1/2 Button Head Socket Cap Allen (8 each)
Screw 1/4-20 x 1-1/4 Socke t Cap (4 each)
Flanged Nut 1/4-20 (12 each)
24-Inch Attachment Bracket (4 each)
Cable Kit Shelf Server (12- foot cables)
Monitor Cable
Keyboard Cable
Mouse Cable
Internal Power Cable
Cable Kit Top Shel f Server (7-fo ot cables)
Monitor Cable
Keyboard Cable
Mouse Cable
Internal Power Cable
76G3627
06P6007
06P6006
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 15
Rack Enclosure Kits (Type 9306) FRU
Miscellaneous Parts Kit
Rack Nut/Holder 10-32 (8 each)
Keeper Nut 8-32 Zinc (8 each)
Keeper Nut 10-32 (6 each)
Screw 6-32 x 5/16 (2 each)
Screw 6-32 x 1/4 Button Head Socket Cap Allen (8 each)
Screw 10-32 x 3/8 Button Head Socket Cap (8 each)
Screw 6-32 x 3/8 Button Head Socket Cap (2 each)
Screw 1/4-20 x 1/2 Button Head Socket Cap (2 each )
Screw 8-32 x 1/4 Button Head Socket Cap Allen (4 each)
Screw 10-32 x 1/4 Button Head Socket Cap (2 each)
Screw 8-32 x 1/4 Button Head Socket Cap (8 each)
Pull-ring, 3-Inch (2 each)
Shoulder Screw 8-32 x 3/8 (2 each)
Standoff,.25 Hex, 6-32 FF,.5-Inch (2 eac h)
Screw 8-32 x 3/8 Button Head Socket cap (2 each)
Screw 10-24 x 1/4 Button Head Socket Allen (2 each)
Screw 10-24 x 5/16 Button head Socket Allen (2 eac h)
Keeper Nut 8-32 (2 each)
Nut 8-32 (2 each)
Captive Weld Nut (2 each)
Whiz-Lock Flange Nut 1/4-20 (2 each)
Keeper Nut 10-32 (2 each)
Bumpers (2 each)
C able Ties (8 each)
07H0057
Server Tray Interlock Kit
Cam (1 each)
Spring (1 each)
07H0091
16 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s

Parts listing (Type 9306 – 24-inch) Models 4QS, 4QX

This parts listing is for Models 4QS and 4QX.
4
29
27 26
6
5
1
28
2
3
30
7
10
8
11
9
12
13
14
25
23
24
22
21
20
19
18
17
15
16
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 17
Index 24-Inch Rack Enclosure (Type 9306) FRU
1 Adapter Plate Options:
PS/2 Server 85/95 76H3733 Model 300 76H3734
Model 500, 700 76H3735 2 Monitor Stand 07H0061 3Server Selector Cable 07H0036 4 Blank Bezel ( 4QX O nl y) 07H 0066 5 Monitor Housing (24-Inc h) 07H0065 6 Server Selector Keypad 07H0097 7 Rack Frame N/A 8 Spacer (see Spacer Kit, right side at end of this FRU list) 07H0059 9 Server Selector Unit Electronics See "Safet y Notice (Multi-lingual Translations) See “Safety
notice (multi-lingual translations) on page 191.
10 Internal Cables (see Cable Kit Top Shelf Server and Cable Kit Bottom Shelf Server) 1 1 Cable Management Arm 07H0087 12 Pin, Cable Management Arm 07H0089 13 Fan 220 V ac with Power Cord 07H0063 14 Rear Door Latch/Lock with Key and Bracket 07H0055 15 Re ar D oo r (2 4 - I nc h ) 07H0047 16 Ex te r nal Powe r C ord :
Australia 14F1559
Europe 14F1554
Israel 14F1561
Italy 14F1560
New Zealand 14F1558
South A m e r i ca , In d i a 14F1557
U.K./Denmark 14F1555
USA 14F1553
External Power Co rd Option - 6 Ft. 07H0094
07H0034
17 Left/Right Side Panel 07H0049 18 NetBAY Rack Power Distributi on Unit 09N9668 18 NetBAY Front-end Power Distribution Unit 09N9670 18 NetBAY Server Dual-cord Power Distribution Unit 09N9669
Hard w a re Ki t for NetBAY Powe r Dist ri butio n Un i t s 09N9 671
18 Power Distribution Unit 07H0424
250 V Slow Blow Fuse 0303549
19 Keyboar d Slides, 24-I nch (one pair) 07H0038
18 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Index 24-Inch Rack Enclosure (Type 9306) FRU
20 Leveling Feet (Qty. 4) 07H0053 21 Stabilizing Leg 07H0051 22 Keyboard Drawer , 24-Inch (wit h Sl id e s and Brackets) 07H0077 23 Slide Rails, Server Tray (one pair) 07H0083 24 24-Inch Front Compartme nt Door (24-Inch by 26-Inch) 07H0058 25 Door Hinge Se t 07H0045 26 Door Valance (4QX Only) 07H0068 27 Handle, Server/Keyboard Tray 07H0085 28 Server Tray 07H0081 29 Mouse Table 07H0079 30 Shelf, Serv e r Tray, 24-Inch 07H0093
Cable, SVGA-Video (15 Feet) 76H3736 Monitor Power Cable (connects from monitor to Power Distribut ion Unit) 07H0075 Rack Keyboard Cable (connects from Keyboard Drawer to Server Selector Unit) 07H0067 Rack Mouse Cable (connects from Keyboard Drawer to Server Selector Unit) 07H0069
Rack Enclosure Kits 24-inch (Type 9306) FRU
Bolt-Together Kit (19-Inch to 24-Inch, 24-Inch t o 19-Inch) – includes: 19-Inch Attachment
76G3627 Bracket (2 ea ch); S cr ew 1/4- 20 x 1/2 But ton Head So cket Ca p; A llen ( 8 each ); Scr ew 1/ 4-2 0 x 1-1/4 Socket Cap ( 4 e ach); Flanged Nut 1/4 -20 (12 each); 24-Inch Attachment Bracket (4 each)
Cable Kit Shelf Server (12 foot cables) – includes: Monitor Cable; Keyboard Cable; Mouse
07H0073 Cable; Internal Power Cab le
Cable Kit Top Shelf Server (7 foot cabl es) – includes: Monitor Cable; Keyboard Cable;
07H0071 Mouse Cable; Internal Power Cable
Miscellaneous Parts Ki t – includes: Rack Nut/Holder 10-32 (8 each); Keeper Nut 8-32 Zinc
07H0057 (8 each); Kee per N ut 10-32 (6 each); Screw 6-32 x 5/16 (2 each); Scr e w 6-32 x 1/4 Button Head Socket Cap ; Allen (8 each); Screw 10-32 x 3/8 Button Head Socket Cap; (8 each); Screw 6-3 2 x 3/8 Button Head Socket Cap; (2 each); Screw 1/4-20 x 1/2 Button Head Socket Cap; (2 each); Scr e w 8-32 x 1/4 Button Hea d Socket Cap; Allen (4 each); Screw 10­32 x 1/4 Button Head Socket Cap; (2 each); Screw 8-32 x 1/4 Button Head Socket Cap; (8 each); Pull -rin g, 3- In ch (2 e ach); Sho ulder S cr ew 8 -32 x 3/ 8 (2 each); S ta ndof f, .2 5 He x, 6- 32 FF, .5-Inch (2 each); Screw 8-32 x 3/8 Button Head Socket cap; (2 each); Screw 10-24 x 1/4 Button Head Sock et Allen; (2 eac h) ; Scre w 10-24 x 5/16 Button head Sock et Alle n; (2 each) ; Keeper Nut 8-32 (2 each); Nut 8-32 (2 each); Captive Weld Nut (2 each); Whiz-Lock Fl ange Nut 1/4-20 (2 each); Keeper Nut 10-32 (2 each); Bumpers (2 each); Cable Ties (8 each)
Server Tray Interlock Kit – includes: Cam (1 each); Spring (1 each) 07H0091 Spacer Kit, Right Side – includes: Rack Joiner (8 each); Spacer, Top and Bottom, 34-Inch (1
07H0059 each); Space r, Body 70-Inch (2 each); Screw 10-32 x 3/8 But ton Head Socket cap; (8 each); Screw 1/4-20 x 1/2 Button Head Sock e t cap; (8 each); Whi z-Lock Flange Nut 1/4 -20 (8 each); Screw 6-32 x 3/8 Butto n H e ad Socket Cap; (6 each)
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 19
20 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s

Type 9306 Model 200

Locked Unlocked
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Selector switch locations . . . . . . . . . . . . . . . . . . . . . 22
Power Distribution Unit. . . . . . . . . . . . . . . . . . . . . . 26
Blank bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fixed shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Keyboard tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Installing a flat panel monitor rack mount kit . . . 29

Features

The IBM NetBAY22, Type 9306, Model 200 Rack enclosure is a 22-U high (38.5-inch) industry-standard, 19-inch rack that houses and controls multiple IBM PC Servers/IBM Servers and related equipment.

Locations

The following sections contain information on specific equipment locations. Note: For instructi ons on how to power-off the rack, see Powering off the rack on
page 3.

Side pa nel

Removing the existing flat panel monitor stand . 29
Installing the new monitor stand. . . . . . . . . . . . . . 31
Starting the system. . . . . . . . . . . . . . . . . . . . . . . . . . 35
Configuring the selector switch . . . . . . . . . . . . . . . 35
Switching among servers . . . . . . . . . . . . . . . . . . . . 36
Advanced selector switch functions . . . . . . . . . . . 37
Resetting the selector switch. . . . . . . . . . . . . . . . . . 45
Making connections under power. . . . . . . . . . . . . 46
Parts Listing (Type 9306 Model 200) . . . . . . . . . . . 47
© Copyright IBM Corp. 2001 21

Selecto r switch locat io ns

Note: For information about the IBM NetBAY Console Switch, see IBM NetBAY
console switch on page 129.
e e r
h
T
e
e r h
T
M
K
o
Tw
M
e
K e r
h T
M
K
o
Tw
M
K e n
O
M
K
t
e
s e R
M
K
.
x
u A
Figure 1. Selector switch in monitor compartment
1
n
0
t
tio
e e r
a
h
T
rm
ortan
o
fo
p
Tw
In
M
Im
K
M
K
22 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Loading...
+ 178 hidden pages