IBM 4QX, 42X, 200, 42E, 900, 4SB, 9TS, 9QX, 4SA, 9QS, 9TX, 42P, 4QS, 42S User Manual
Hardware Maintenance Manual
IBM PC Server/Enterprise Racks
IBM
Hardware Maintenance Manual
IBM PC Server/Enterprise Racks
IBM
Note:
Before using this info rm atio n and the produ ct it supp or ts , be sure to read th e gen era l
information under “Notices” on page 195.
Sixth Edition (November 1999) Updated April 2001
The following paragraph does not apply to the United Kingdom or any country where such provisi ons are
incons istent with local law :
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow
disclaimer of express or implied warranties in certain transactio ns, th erefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the
information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements
and/or changes in the product(s) and/or the program( s) described in this publication at any time.
This publication was developed for products and services offered in the United States of America. IBM may not offer the
products, services, or features discussed in this document in other countries, and the information is subject to change
without notice. Consult your local IBM representative for information on the products, services, and features available in
your area.
Requests for technical information about IBM products sho uld be made to your IBM reseller or IBM marketing
representative.
This supplement should be used with the related service information in the IBM PC
Servers Hardwar e Ma intenance Manual (part number 70H0751, form number S30H2501-01).
Important: This manual is intended for trained servicers who are familiar with IBM
PC Server and IBM Server products.
Before servicing an IBM product, be sure to review “Safety info rma tion”
on page 183.
Related publicat ion s
The following publications are available for IBM products. For more information,
contact IBM or an IBM Author ized Dealer.
PC ServersIBM PC Servers Hardware Maintenance Manual
(S30H-2501)
PS/2 Computers IBM Personal System/2 Hardware Maintenance
Manual (S52G-9971)
PS/ValuePoint Compute r s IBM PS/ValuePoint Hardware Maintenance Service
and Refere nce (S61G-1423)
Laptop, Notebook, Portable, and
ThinkPad Computers (L40 , CL57, N45,
N51, P70/P 75, ThinkPad 300, 350, 500,
510, 710T, Expansi on Unit, Dock I,
Dock II)
Use the following procedur e for diagnosing keyboard, mouse, and video pr oblems for
the IBM PC Server Rack Enclosure and the IBM Rack enclosures (Type 9306 and Type
9308).
For power problems, see “Power checkout” on page 2.
Attention:
•For Models 4QS, 4QX, 9QS, 9QX, 9T S, 9TX only:
Ensure that the voltage se lector switch on each server installed in the server rack
is set to 230 V ac.
•For Models 200, 900 only:
Ensure that the voltage se lector switch on each server installed in the server rack
is set to the proper voltage as supplied by the Power Distribution Unit, PDU.
1.Check the foll owing:
•Ensure the external power cord is in good condition and properly connected
to a known-good power source.
•Ensure the internal power cables are in good condition and properly
connected. (The internal power cables connect between the power
distrib ution unit and the servers insta ll e d in the server rack.)
•Ensure the following devices are power ed on.
a.Power distribution unit
b.Server select or unit
c.All system units
d. Display
2.If the items/conditions specified in step 1. are not okay, correct the problem and
verify that the server rack is operating correctly.
3.If the items/conditions specified in step 1. are okay, then, using the server selector
keypad buttons, check the operation of the failing device for all of the servers that
are installed in the rack.
4.Did the failure occur on more than one server?
•NO: Go to the Hardware Mai ntenance manual for the serv e r th at was
selected when the failure occurred. Disconnect the keyboard an d mouse from
the server selector unit and connect them directly to the failing server. Then,
run the server diagnostic programs on the failing server.
If the problem still remains, disconnect the keyboard and mouse from the
failing server and reconnect them to the server selector unit. Then, replace the
server rack components in the following order until the problem goes away.
a.Device cable (connects between the server selector unit and the server
b. Server selector cable (connects between the server selector keypad and
the server selector unit).
c.Server selector keypad.
d. Server selector unit.
•YES: Power-off the server rack and replace the server rack components in the
following order until the probl em goes away. See “Powering off the rack” on
page 3.
a.Device extender cable (connects between the device and the server
selector unit)
b. Failing device
c.Server selector cable (connects between the server selector keypad and
the server selector unit)
d. Server selector keyp ad
e.Server selector unit
Use the following procedure for diagnosing power problems for the IBM PC Server
Rack Enclosure and IBM Rack enclosure (Type 9306).
Attention:
•For Models 4QS, 4QX, 9QS, 9QX, 9T S, 9TX only:
Ensure that the voltage se lector switch on each server installed in the server rack
is set to 230 V ac.
•For Models 200, 900 only:
Ensure that the voltage se lector switch on each server installed in the server rack
is set to the proper voltage as supplied by the Power Distribution Unit, PDU.
1.Check the foll owing:
•Ensure the external power cord is in good condition and properly connected
to a known-good power source.
•Ensure the internal power cables are in good condition and properly
connected. (The internal power cables connect between the power
distrib ution unit and the servers insta ll e d in the server rack.)
•Ensure the following devices are power ed on.
a.Power distribution unit
b. Server selector unit
c.All system units
d. Display
2.If the items/conditions in step 1. are not okay, correct the problem and verify
correct operation of the server rack.
3.If the items/conditions specified in step 1. are okay, then, using the server selector
keypad buttons, check for correct operatio n of all the serve rs installe d in the rack .
4.Did the failure occur on more than one server?
•No: Go to the Hardware Maintenan ce manual for the ser ver that was sel ected
when the failure occurred and run the server diagnostic programs. If the
problem still remains, replace the powe r distr ibut io n unit.
2Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
•Yes: Power-off the server rack and replace the server rack components in the
Powering off the rack
Before performing service on the rack, follow this procedure to prevent personal
injury and to avoid damaging the rack and the installed servers.
To power-off the IBM PC Server Rack:
1.Shut down and power-off all installed servers.
2.Power-off the serve r selector unit.
3.If a UPS system is installed in the rack, power-off the UPS system.
4.Disconne ct p o wer from the IBM PC Server Rack.
•If the rack is plugged into a wall-mounted power supply, disconnect the
•If the power cord is wired directly into the installed location's power supply,
following order until the probl em goes away. See “Powering off the rack” on
page 3.
a.Power distribution uni t fuse.
b. Power distribution unit.
power cord plug from the wall socket.
open the rear door of t he rack cabinet and disconnect th e power plug from the
base of the p o we r distri b uti o n u ni t .
IBM PC Server/Enterprise rack enclosures 3
4Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
The 9306 IBM PC Server Rack E nclosure, models 4QS, 9QS, 9TS come i n thr ee primary
models.
•19-inch Quad Primary Server Rack, Model 9QS
•19-inch Tri Primary Server Rack, Mode l 9TS
•24-inch Quad Primary Server Rack, Model 4QS
A Quad Primary Server Rack can house up to four IBM PC Servers. The Tri Primary
Server Rack can house up to three IBM PC Servers.
Both Quad and Tri Primary Server Racks provide a built in serv er selec tor wh ich
connects to one set of cons ole devices (moni tor , keyboard, and mouse.) The se rver
selector works independently from the server's operating systems, enabling the
connected servers to run different operating systems.
Parts listing (Type 9306 – 24-inch) Models 4QS, 4QX
17
IBM PC Serv er expansio n rack models
Locations
These IBM 9306 PC Server Rack Enclosure models are shipped preassembled and precabled.
Three optional IBM PC Server Rack Expansion models are available to expand the
capacity of the IBM PC Server Rack Primary Enclosure. The optional IBM PC Server
Rack Expansion models are:
•19-inch Quad Expansio n Rac k, Model 9Q X
•19-inch Tri Expansion R ack, Mo del 9TX
•24-inch Quad Expansio n Rac k, Model 4Q X
The IBM PC Server Rack Ex p ansion m od els allo w th e instal lation of u p to four more
servers using the Primary IBM PC Server Rack monitor, keyboard, and mouse.
The following sections contain information on specific equipment locations.
Note: For instructi ons on how to power-off the rack, see “Powering off the rack” on
3.Disconn e ct the server selector cable from the back of the server selector console.
4.Remove the server selector console from the cabinet.
Server
Monitor
Bezel
Selector
Console
Server
Selector
Keypad
Serve r sel ect or un it
The server selector unit is located in the upper rear of the rack cabinet. The server
select or unit can only be acces s e d or remo v e d fro m the rea r of th e IB M Ra ck ca b in et.
CAUTION:
The server selector unit is heavy. You will need two people to safely remove the
server selector unit. See “Safety notice (multi-lingual translations)” on page 191.
To remove the server selector unit:
1.Power-off th e rack.
2.Unplug the keyboard, mouse, video cables, and the power cord.
3.Remove the ser ve r selector console.
4.With one person brac ing the server se lector unit f rom below, have the second
person use a 5/16-inch wrench to remove the four nuts that secure the server
selector unit to the rack cabinet.
5.Remove the server selector unit from the cabinet.
Note: When replac ing the ser ver sel ector unit , be sure t hat t he Server Sel ector ca ble is
fed throu gh the indentation along the lef t side of the server selector uni t.
Server
Selector
Electronics
Server
Selector
Cable
6Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
Server
Selector
Cable
Connections
Server Rack
Monitor
Connection
AC Power
Input
Server
Monitor
Connections
Server
Selector
Unit
Server Selector
Unit On-Off
Switch
M
O
N
O
K
B
O
Server Rack
Keyboard
Connection
G
G
A
A
2
1
M
K1M1K2M2K3M3K4M4K5M5K6M6K7M7K8M
O
U
Server Rack
Mouse
Connection
G
G
A
A
4
3
Server Keyboard
and Mouse
Connections
V
V
V
V
Power distributi on unit
Note: For information and installa tion instructi ons for the IBM NetBAY Rack Power
Distribu tion Units, see “Net BAY Power Distribution Units” on page 141".
Note: To remove the power distribution unit, you might need to remove the right
side cabinet panel, the server installed in sliding tray 2 (in the primary IBM PC
Server Rack), or sliding tray 5 (in the IBM PC Server Expansion Rack).
V
V
G
G
A
A
6
5
V
V
G
G
A
A
8
7
8
To remove the power distribution unit:
1.Power-off th e rack.
2.Disconnect all power plugs from the power distribution unit.
3.Using a Phillips screwdriver, remove the four screws from the front of the power
distrib u tion unit.
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 7
Note: These screws ar e held in place by nuts and washers. Hold the nut while
you are unscrewing the screw to prevent the nut and washer from falling
into the bottom of the cabinet.
4.Remove the po we r distribu tion unit from the cabinet.
AC Power
Input
AC Fuse
Circuit
Breaker
115V AC
Power-On
Indicator
Voltage
Selection
Switch
230V AC
Power-On
Indicator
AC Power
Output
Cooling fan
To remove the cooling fan:
1.Power-off th e rack.
2.Open the rear door of the rack cab inet.
3.Disconnect the power plug from the rear of the cooling fan.
4.Use a 5/16-inch wrench to remove the eight nuts that secur e the cooling fan to the
top of the ra ck cabine t.
5.Remove the cooling fan from the cabinet.
Note: When installing the fan, make sure that the green and yellow ground wire is
attached to one of the top fan mounting screws and that the strain-relieving
clamp is attached to another. The power cable should be secured by the strainrelieving clamp.
8Hardware Maintenance Manual: IBM PC Server/Enterprise Racks
Sliding trays
Models 4QS and 4QX come with either single latch slide rails or dual latch slide rails.
Single latch slide rails have a front latch release on the right rail only. Dual latch slide
rails have a front latch release on both rails. The slide rail FRU number for the 24-inch
rack replaces the single latch slide rail with the dual latch slid e rail.
Note: If a server is installed on a tray being removed, first remove the server.
Single latch rail tray
To remove a sliding tray with single latch rails:
1.Power-off th e rack.
2.Open the rear door of the rack cabinet and remove the pin 1 that secures the
slidin g tr ay to the cable manage me nt arm
3.Loosen the thumbscrews 2 on the sliding tray and fully extend the sliding tray.
4.Use a 3/32-inch allen wrench to remove the five screws 3 from the left side of the
sliding tray.
5.Lift the rear locking tab 4 and push the sliding tray approximately two inches into
the cabinet.
6.Release the forward locking tab 5. Then, while holding the sliding tray in place,
use your other hand to grasp the outside sliding rail 6 and push it into the rack
cabinet until it disconnects from the sliding tray.
Ground
Wire
Power
Plug
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 9
Dual latch rail tray
To remove a sliding tray with dual latch ra ils:
1.Power-off th e rack.
2.Open the rear door of the rack cabinet and remove the pin 1 that secures the
slidi ng tray to the cable managemen t arm.
3.Loosen the thumbscrews 2 on the sliding tray and fully extend the sliding tray.
4.Push in on the spring of the right rear locking tab 3 and push the sliding tray
approximately two inches into the cabinet.
5.Release both left and right forward locking tabs 4. Then, while holding the
sliding tray in place, push bo th left and righ t ou tside sli ding rails 5 into the rack
cabinet until it disconnects from the sliding tray.
Note: Left side view for 4 and 5 are not show n.
Sliding rails
This procedure is for single latch sliding rails and dual latch sliding rails.
For single latch sliding rails, the right rail is the one that has the front latch. The left
rail doe s n o t h a ve a fron t l a tc h .
For dual latch sliding rails, the right rail is the one that has the rear latch. The left rail
does not have a rear latch.
To remove the sliding rails:
1.Power-off th e rack.
2.Remove the sliding tray that is attached to the sliding rails that you want to
remove. See “Sliding trays” on page 9.
3.Use a 3/32-inch allen wrench to remove the four screws that secur e each of the
sliding rails to the rack cabin et.
10 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Note: You will need to adjust the position of the sliding rail in order to line up the
access holes over the locations of the screws.
Keyboard tray
To remove the keyboard tray:
1.Power-off th e rack.
2.Disconnect the keyboard and mouse cables from the ke y board and mouse
extension cables.
3.Remove the keyboard and mouse from the keyboard tray.
4.Pu ll the keybo a rd tray straig ht out of the ra ck cabine t.
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 11
Parts listing (Type 9306 – 19-inch) Models 9QS, 9TS and 9QX, 9TX
This parts listi ng is for Models 9QS, 9TS and 9QX, 9TX
4
8
6
5
3
7
9
10
11
27
28
1
26
2
30
29
24
23
19
20
22
25
21
18
17
13
12
14
15
16
12 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Index19-Inch Rack Enclosure (Type 9306)FRU
1Adapter Plate Options:
PS/2 Server 85 /9576H3733
Model 30076H3734
Model 500, 70076H3734
2Monitor Stand07H0061
3Server Selector Cable07H0036
4Blank Bezel (9QX, 9TX Expansion units only)76H0379
5Monitor Bezel wit h button label76H0378
6Server Selector Keypad07H0097
7Monitor Housing (19-inch)76H0377
8Server Selector Unit Elect ronics
07H0034
See “Safety inspection guide” on page 192.
9Internal Cables
06P6007
See Cable Kit Shelf Server
10Cable Management Arm76H0386
11Cable Management Arm Single Server Tray76H0387
12Pin, Cable Manageme nt Arm07H0089
13Fan 220 V ac with Power Cord07H0063
14Latch, Rear Door76H0376
15Rear Door (19-Inch)76H0373
15Hinge Set for Rear Doo r76H0389
16External Powe r Cord:
Australia14F1559
Europe14F1554
Israel14F1561
Italy14F1560
New Zealand14F1558
South America, India14F1557
U.K./Denmark14F1555
USA14F1553
External Powe r Cord Option - 6 Ft.07H0094
17Left/Right Side Panel76H0374
18Caster76H3626
19NetBAY Rack Power Distribution Unit09N9668
19NetBAY Front-end Power Distribution Unit09N9670
3-phase NEMA L21-30P line cord (200-250 Vac) for NetBAY Front-end PDU00N7720
3-phase IEC 309 -3P+N+Gnd line co rd (380-415 Vac) for NetBAY Front-end PDU00N7721
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 13
Index19-Inch Rack Enclosure (Type 9306)FRU
1-phase NEMA L5-30P line cor d (100-127 Vac) for NetBAY Front-end PDU00N7722
1-phase NEMA L6-30P line cor d (200-240 Vac) for NetBAY Front-end PDU00N7723
1-phase IEC 309 -2P+Gnd line cord (200-240 Vac) for NetBAY Front-end PDU00N7724
19NetBAY Server Dual-cord Power Distribution Unit09N9669
Hardware Kit for NetBAY Power Distri bution Units09N9671
Power Distribution Unit07H0424
19250 V Slow Blow Fuse0303549
20Keyboard Sl ides, (one pair)07H0038
21Leveling Foot (Qty. 1)76H0390
22Stabilizing Bar76H0375
23Keyboard Tray, 19-Inch76H0381
24Slide Rails , Server Tray (one pair )07H0083
24Slide Rails, Dual T r ay (one pair)76H0383
2519-inch Front Compartment Door (19-Inch by 26-Inch) Includes Hinge Set and Screws76H0371
26Door Hinge Set76H0372
27Door Valance (9QX, 9TX, Expansion units only)76H0380
28Mouse Table07H0079
29Dual Server Tray76H0382
29Dual Server Shelf76H0385
30Single Server Tray76H0384
19-Inch Single Slide Shelf for an Industry Standard 19-Inch Rack.76H3628
Cable, SVGA-Video (15 Feet) Opt i on76H3736
Monitor Power Cabl e (connects from monitor to Power Dist ri bution Unit)07H0075
Rack Keyboar d Cable (connects from Keyboard Drawer to Serv e r Sel e ctor Unit)07H0067
Rack Mouse Cable (connects from Ke yboard Drawer to Serve r Se lector Unit)07H0069
14 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Rack Enclosure Kits (Type 9306)FRU
Bolt-Together Kit (19-Inch to 24- Inch, 24-Inch to 19- Inch)
•19-Inch Attachment Bracket (2 each)
•Screw 1/4-20 x 1/2 Button Head Socket Cap Allen (8 each)
•Screw 1/4-20 x 1-1/4 Socke t Cap (4 each)
•Flanged Nut 1/4-20 (12 each)
•24-Inch Attachment Bracket (4 each)
Cable Kit Shelf Server (12- foot cables)
•Monitor Cable
•Keyboard Cable
•Mouse Cable
•Internal Power Cable
Cable Kit Top Shel f Server (7-fo ot cables)
•Monitor Cable
•Keyboard Cable
•Mouse Cable
•Internal Power Cable
76G3627
06P6007
06P6006
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 15
Rack Enclosure Kits (Type 9306)FRU
Miscellaneous Parts Kit
•Rack Nut/Holder 10-32 (8 each)
•Keeper Nut 8-32 Zinc (8 each)
•Keeper Nut 10-32 (6 each)
•Screw 6-32 x 5/16 (2 each)
•Screw 6-32 x 1/4 Button Head Socket Cap Allen (8 each)
•Screw 10-32 x 3/8 Button Head Socket Cap (8 each)
•Screw 6-32 x 3/8 Button Head Socket Cap (2 each)
•Screw 1/4-20 x 1/2 Button Head Socket Cap (2 each )
•Screw 8-32 x 1/4 Button Head Socket Cap Allen (4 each)
•Screw 10-32 x 1/4 Button Head Socket Cap (2 each)
•Screw 8-32 x 1/4 Button Head Socket Cap (8 each)
•Pull-ring, 3-Inch (2 each)
•Shoulder Screw 8-32 x 3/8 (2 each)
•Standoff,.25 Hex, 6-32 FF,.5-Inch (2 eac h)
•Screw 8-32 x 3/8 Button Head Socket cap (2 each)
•Screw 10-24 x 1/4 Button Head Socket Allen (2 each)
•Screw 10-24 x 5/16 Button head Socket Allen (2 eac h)
•Keeper Nut 8-32 (2 each)
•Nut 8-32 (2 each)
•Captive Weld Nut (2 each)
•Whiz-Lock Flange Nut 1/4-20 (2 each)
•Keeper Nut 10-32 (2 each)
•Bumpers (2 each)
•C able Ties (8 each)
07H0057
Server Tray Interlock Kit
•Cam (1 each)
•Spring (1 each)
07H0091
16 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Parts listing (Type 9306 – 24-inch) Models 4QS, 4QX
This parts listing is for Models 4QS and 4QX.
4
29
27
26
6
5
1
28
2
3
30
7
10
8
11
9
12
13
14
25
23
24
22
21
20
19
18
17
15
16
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 17
Index24-Inch Rack Enclosure (Type 9306)FRU
1Adapter Plate Options:
PS/2 Server 85/9576H3733
Model 30076H3734
Model 500, 70076H3735
2Monitor Stand07H0061
3Server Selector Cable07H0036
4Blank Bezel ( 4QX O nl y)07H 0066
5Monitor Housing (24-Inc h)07H0065
6Server Selector Keypad07H0097
7Rack FrameN/A
8Spacer (see Spacer Kit, right side at end of this FRU list) 07H0059
9Server Selector Unit Electronics See "Safet y Notice (Multi-lingual Translations) See “Safety
notice (multi-lingual translations)” on page 191.
10Internal Cables (see Cable Kit Top Shelf Server and Cable Kit Bottom Shelf Server)
1 1Cable Management Arm07H0087
12Pin, Cable Management Arm07H0089
13Fan 220 V ac with Power Cord07H0063
14Rear Door Latch/Lock with Key and Bracket07H0055
15Re ar D oo r (2 4 - I nc h )07H0047
16Ex te r nal Powe r C ord :
Australia14F1559
Europe14F1554
Israel14F1561
Italy14F1560
New Zealand 14F1558
South A m e r i ca , In d i a 14F1557
U.K./Denmark14F1555
USA14F1553
External Power Co rd Option - 6 Ft.07H0094
07H0034
17Left/Right Side Panel07H0049
18NetBAY Rack Power Distributi on Unit09N9668
18NetBAY Front-end Power Distribution Unit09N9670
18NetBAY Server Dual-cord Power Distribution Unit09N9669
Hard w a re Ki t for NetBAY Powe r Dist ri butio n Un i t s09N9 671
18Power Distribution Unit07H0424
250 V Slow Blow Fuse0303549
19Keyboar d Slides, 24-I nch (one pair)07H0038
18 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Index24-Inch Rack Enclosure (Type 9306)FRU
20Leveling Feet (Qty. 4)07H0053
21Stabilizing Leg07H0051
22Keyboard Drawer , 24-Inch (wit h Sl id e s and Brackets) 07H0077
23Slide Rails, Server Tray (one pair)07H0083
2424-Inch Front Compartme nt Door (24-Inch by 26-Inch)07H0058
25Door Hinge Se t07H0045
26Door Valance (4QX Only)07H0068
27Handle, Server/Keyboard Tray07H0085
28Server Tray07H0081
29Mouse Table07H0079
30Shelf, Serv e r Tray, 24-Inch07H0093
Cable, SVGA-Video (15 Feet)76H3736
Monitor Power Cable (connects from monitor to Power Distribut ion Unit)07H0075
Rack Keyboard Cable (connects from Keyboard Drawer to Server Selector Unit)07H0067
Rack Mouse Cable (connects from Keyboard Drawer to Server Selector Unit)07H0069
Rack Enclosure Kits 24-inch (Type 9306)FRU
Bolt-Together Kit (19-Inch to 24-Inch, 24-Inch t o 19-Inch) – includes: 19-Inch Attachment
76G3627
Bracket (2 ea ch); S cr ew 1/4- 20 x 1/2 But ton Head So cket Ca p; A llen ( 8 each ); Scr ew 1/ 4-2 0
x 1-1/4 Socket Cap ( 4 e ach); Flanged Nut 1/4 -20 (12 each); 24-Inch Attachment Bracket (4
each)
Cable Kit Top Shelf Server (7 foot cabl es) – includes: Monitor Cable; Keyboard Cable;
07H0071
Mouse Cable; Internal Power Cable
Miscellaneous Parts Ki t – includes: Rack Nut/Holder 10-32 (8 each); Keeper Nut 8-32 Zinc
07H0057
(8 each); Kee per N ut 10-32 (6 each); Screw 6-32 x 5/16 (2 each); Scr e w 6-32 x 1/4 Button
Head Socket Cap ; Allen (8 each); Screw 10-32 x 3/8 Button Head Socket Cap; (8 each);
Screw 6-3 2 x 3/8 Button Head Socket Cap; (2 each); Screw 1/4-20 x 1/2 Button Head
Socket Cap; (2 each); Scr e w 8-32 x 1/4 Button Hea d Socket Cap; Allen (4 each); Screw 1032 x 1/4 Button Head Socket Cap; (2 each); Screw 8-32 x 1/4 Button Head Socket Cap; (8
each); Pull -rin g, 3- In ch (2 e ach); Sho ulder S cr ew 8 -32 x 3/ 8 (2 each); S ta ndof f, .2 5 He x, 6- 32
FF, .5-Inch (2 each); Screw 8-32 x 3/8 Button Head Socket cap; (2 each); Screw 10-24 x 1/4
Button Head Sock et Allen; (2 eac h) ; Scre w 10-24 x 5/16 Button head Sock et Alle n; (2 each) ;
Keeper Nut 8-32 (2 each); Nut 8-32 (2 each); Captive Weld Nut (2 each); Whiz-Lock Fl ange
Nut 1/4-20 (2 each); Keeper Nut 10-32 (2 each); Bumpers (2 each); Cable Ties (8 each)
Server Tray Interlock Kit – includes: Cam (1 each); Spring (1 each)07H0091
Spacer Kit, Right Side – includes: Rack Joiner (8 each); Spacer, Top and Bottom, 34-Inch (1
07H0059
each); Space r, Body 70-Inch (2 each); Screw 10-32 x 3/8 But ton Head Socket cap; (8 each);
Screw 1/4-20 x 1/2 Button Head Sock e t cap; (8 each); Whi z-Lock Flange Nut 1/4 -20 (8
each); Screw 6-32 x 3/8 Butto n H e ad Socket Cap; (6 each)
Type 9306 Mod els 4QS, 4QX, 9QS , 9Q X, 9TS, 9TX 19
20 Hardware Ma intena nce Manual: IBM PC Server/Enterprise Rack s
Installing a flat panel monitor rack mount kit . . . 29
Features
The IBM NetBAY22, Type 9306, Model 200 Rack enclosure is a 22-U high (38.5-inch)
industry-standard, 19-inch rack that houses and controls multiple IBM PC
Servers/IBM Servers and related equipment.
Locations
The following sections contain information on specific equipment locations.
Note: For instructi ons on how to power-off the rack, see “Powering off the rack” on
page 3.
Side pa nel
Removing the existing flat panel monitor stand . 29