HYT h2 Instruction Manual

Page 1
INSTRUCTION MANUAL AND GUARANTEE
H2
Page 2
2
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
Thank you and congratulations!
With this HYT watch, you have joined the age of Hydro-Mechanical Horology.
HYT represents the link between traditional watchmaking and uid mechanics.
Whichever model you have chosen, it will be part of the same uncompromising HYT philosophy, which is to offer the best in traditional watchmaking combined with unlimited hydro-mechanical creativity.
Grégory Dourde
CEO
Page 3
3
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
GUARANTEE
In this manual, you can nd the basic instructions for using and maintaining your watch.
Each HYT watch bears an individual identication number, which guarantees both its authenticity, and that all the work involved in its creation has been supervised by a master watchmaker.
Each HYT watch is equipped with a uidic module
0
. The uidic module is the device which enables the time to be displayed via the meniscus1. The meniscus marks the boundary between the two immiscible uids in the capillary3. The watch movement drives the module via the bellows2 xed on the main plate. Only a professional watchmaker approved by HYT can replace this uidic system. It bears a unique serial number.
The card you received when you purchased your watch is the electronic guarantee certicate for your HYT watch.
The QR Code on the front of your card gives you access to unique and interactive content, once you have downloaded the app. This content explains the correct way to use your watch, with specic videos and texts. The guarantee is activated upon purchase in our network of approved HYT retailers. You must present your activated guarantee card to be entitled to the guarantee. If following your purchase you have not received a conrmation e-mail, please go to www.hytwatches.com/lounge. Then select the market place corresponding to your mobile. The app will ask you to scan the QR Code and enter your e-mail, in order to send you a password. By downloading this app, you will be able to contact our customer services in a single click in case of an incident or if you have any questions.
Your HYT watch is guaranteed against all manufacturing defects for ve years from the date it was purchased, if the watch was purchased from an approved HYT retailer. This guarantee does not however cover damage caused by incorrect handling or improper use of the watch.
For any service, repair or maintenance procedure, please ensure you only use retailers approved by HYT or our customer services.
You can nd the list of our network of approved retailers and our customer services on our website www.hytwatches.com.
Any repair or maintenance work carried out by third parties who have not been approved by HYT will automatically void the guarantee. Any damage caused will then have to be repaired at your expense.
Page 4
4
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
C
PRECAUTIONS FOR USEPRECAUTIONS FOR USE
Your HYT watch is set and ready to be worn.
The meniscus
1
in the capillary3 displays the time continuously while the watch is on your
wrist, even if you wear it in extreme temperatures (0°C to +50°C).
Important : If you plan to not wear the watch for a while, the coloured liquid has to be stored in its own reservoir (on the left bellows
2
).
To do this, unscrew the crown and pull it out to position C (time setting). Allow the coloured liquid to move into “Zone II” until it starts its retrograde (ensure the time needed for this movement is respected). Once the retrograde phase is complete (coloured liquid in “Zone I”), ensure that the crown remains in the time setting position C. Your watch is now ready to be stopped for an extended period.
The capillary
3
is then filled with transparent liquid (it is possible to still see some coloured liquid in “Zone I”).
Produced and tested to very stringent criteria, the constituent components of your HYT watch together form an exceptionally water resistant unit (to a depth of 50 metres). To ensure these qualities are preserved, we recommend that you replace the gaskets every 3 years. Temperature variations, moisture, perspiration or repeated impacts may adversely affect its water resistance over the years.
With its water resistant case, your HYT watch is fully washable. It should be cleaned regularly in lukewarm, soapy water, rinsed and then carefully dried with a soft cloth. After exposure to sea water, rinse your HYT watch in fresh water.
Zone I Zone II
Page 5
5
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
1
3
2
4
5
QUICK GUIDE
p.7
SCREW-DOWN CROWN
p.8
WINDING
p.9
SETTING THE TIME
p.10
POWER RESERVE INDICATOR
p.13
p.12
DISPLAY TIME EXAMPLES
THERMAL INDICATOR
p.14
p.15
CROWN POSITION INDICATOR (H-N-R)
GLOSSARY
p.6
SETTING THE TIME COUNTER CLOCKWISE
p.11
Page 6
6
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
0. Fluidic module:
To create a liquid time indicator that is compact, wearable and multi-purpose, HYT
has developed a completely new high-tech concept, using two exible bellows at each end of a capillary tube. The system is sealed in accordance with the most stringent standards used in the aerospace industry, with each bellow containing immiscible liquids. The uidic module represents this complete system.
1. Meniscus:
The two liquids are separated by the positive and negative polarities of their respective
molecules that keep them apart like magnetic repulsion. The meniscus marks the surface separating the liquids in the tube, indicating the time.
2. Bellows:
The bellows are the two reservoirs located at 6 o’clock. They are made of a highly
resistant, exible electro-deposited alloy four times ner than a human hair. The movement compresses the left-hand bellows which is emptied of its coloured liquid. The other bellows then lls, and vice versa, moving the liquid within the capillary, and with it the meniscus which indicates the time.
3. Capillary:
This tube, made from the best quality glass as used in the medical industry, is circular in
shape and contains two immiscible liquids. A nanometric surface treatment is applied to this inside of the capillary, which enables the two liquids to move smoothly without adhering to the glass.
4. Retrograde:
When the coloured liquid gets to 6 o’clock (Zone II), it switches to retrograde mode,
owing back to its original position (Zone I).
GLOSSARY
Page 7
7
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
2
1
4
3
6
A
B
C
5
A’
QUICK GUIDE
1. Time display
2. Minute hand
Crown settings
Pos A.: crown screwed down - “N” Pos A’.: crown (unscrewed) - “N” Pos B.: winding (pulled out) - “R” Pos C.: time setting - “H” (pulled out)
3. Thermal indicator
4. Power reserve indicator (located on the case back)
5. Crown position indicator (H-N-R)
Page 8
8
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
A
SCREW-DOWN CROWN
Pos A.
INTRODUCTION
This type of crown provides excellent protection to ensure the case is water resistant.
The crown must be unscrewed before changing the watch settings and screwed back down afterwards.
HOW TO USE
• Unscrew the crown before changing the watch settings
• Afterwards, push the crown back in against the case and screw it back down
• Check from time to time that the crown is fully screwed down.
Page 9
9
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
B
A
WINDING
Pos B.
INTRODUCTION
This function ensures that the power required to drive your watch is stored by the movement.
HOW TO USE
• Unscrew the crown before changing the watch settings “A”
• Wind the watch by turning the crown clockwise “B”
• Afterwards, push the crown back in against the case and screw it back down “A”.
The power reserve indicator is visible on the case back
of the H2
Page 10
10
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
C
B
SETTING THE TIME
Pos C.
10 minutes = 1 crown movement = 1 sec of manipulation
INTRODUCTION
This function allows the time shown on your watch to be set using the crown.
IMPORTANT
• Moving the microuids within the capillary3 should be approached with as much caution as setting a perpetual calendar or a minute repeater
• We highly recommend that the uid is only moved 10 minutes with each movement of the crown
• This should mean that moving the fluid a full hour takes no more than 12 seconds.
HOW TO USE
• Unscrew the crown and pull it out to position “C”
• Then turn the crown in either direction until the coloured liquid (hour display) and the minute hand is at the time required
• Push the crown in completely against the case
• Do not forget to screw in the crown completely to ensure its water resistance.
RETROGRADE
• The automatic return of the coloured liquid (retrograde)4 is allowed by the pressure of the two
bellows2. The speed is higher when the retrograde4
starts in “Zone II” and is minimal when the liquid approaches its starting point in “Zone I”.
Zone I Zone II
Page 11
11
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
Zone I
IMPORTANT NOTICE
A spring is loaded to activate the jumping section of the minute hand when it reaches “30”. When setting the time counter clockwise, the minute hand must go back up to the minute “50” in order to load the spring.
EXAMPLE
At 4:15 you want to set your watch at 3:15
INCORRECT HANDLING
T1: 4:15 T2: time set
directly to 3:15
T3: NO jump
at 3:30
Result: at 3:45 the
hand shows 3:37
CORRECT HANDLING
T1: 4:15 T2: set the time
counter clockwise to 3:15
T3: jump
at 3:30
Result: at 3:45
the uid and the hand show 3:45
T’: set the time
counter clockwise to 2:50
It is completely possible to set your watch counter clockwise.
Warning: counter clockwise movement of the crown must be stopped immediately if the coloured liquid is no longer visible or if it is stored in “Zone I”.
SETTING THE TIME COUNTER CLOCKWISE
Page 12
12
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
DISPLAY TIME EXAMPLES
2) 10:35 am
3) 5:50 pm
1) 6:30 am
Page 13
13
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
POWER RESERVE INDICATOR
Empty Full
INTRODUCTION
This power reserve indicator function provides a real-time display of your watch’s power, thereby indicating how long it will continue to run without the spring being rewound.
To observe this indication, you have to turn the watch over.
HOW TO USE
The two barrels use two different signals: “LOW”, located on the left barrel, and “HIGH” on the right barrel (see the image above).
When the mainsprings are wound, the arrow points to the “HIGH” signal; the power reserve is “full”, representing 8 days of power reserve.
When the mainsprings are unwound, the arrow points to the “LOW” signal; the power reserve is “empty”, and the movement needs to be wound (see WINDING)
To ensure optimal operation of the watch, we recommend that you check the movement is fully wound (see WINDING).
Page 14
14
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
THERMAL INDICATOR
INTRODUCTION
This thermal indicator shows if the watch is in its optimal temperature range to be handled.
When the hand points to the
area, the temperature of the watch is less than 15°C. In
this case, we recommended that handling of your watch is avoided - particularly any
retrograde4 movement.
When the hand points to the
area, the temperature of the watch is higher than 15°C.
The watch can be handled with care (see SETTING THE TIME).
The hand will move back to the white area after your watch is worn for 30-40 min.
<15°C >15°C
Page 15
15
HYT SA - Route des Falaises 74 2000 Neuchâtel - Switzerland
CROWN POSITION INDICATOR (H-N-R)
INTRODUCTION
The crown-position hand (H-N-R) lets you know whether you are in time setting mode (H), power reserve winding mode (R) or in the centre (N), when the crown is in its original position.
Neutral
position
(P. 8)
Time setting position
(P. 10)
Winding position “Remontage”
(P. 9)
Loading...