HySecurity MX001092, MX001308, MX002065, MX001908, MX3402 Installation Instructions Manual

...
Page 1
MX001092, MX001093, MX001308, MX001908, MX002065, MX3753, MX3402
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
Changing the Start Switch or Capacitor
Installation Instructions
Tools Needed
To avoid risk of injury or death, turn off the gate operator and disconnect it from the main power source prior to performing any of the following procedures!
Leeson Motor: Replacing the Start Switch
Fastener secures the start switch
Motor
mounts
Start Switch
Fastener secures the start switch
Juncon box
front panel
Leeson Motor
Page 2
Motor mounts
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
Start Switch
Rubber seal
Leeson Motor: Replacing the Capacitors
Juncon box front panel
Capacitors with enclosures
Fasteners (2 for each enclosure)
Leeson Motor
Page 3
Leeson Motor — External Wiring Diagram
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
Page 4
To avoid risk of injury or death, turn off the gate operator and disconnect it from the
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
main power source prior to performing any of the following service procedures!
Two fasteners secure the Start Switch
Baldor Motor: Replacing the Start Switch
Baldor Motor: Replacing the Capacitors
Pin 4
Pin 3
Pin 2
Four fasteners hold
the front panel to
the juncon box Motor mounts
Juncon box and
front panel
Pin 1
Capacitor enclosure
Baldor Motor
Spade Connections to
Starter Switch
Page 5
White with
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
black stripe
White with blue stripe
One wire per terminal.
Capacitor Wiring
Spring retainer
Lead end
Interior stando
Insulator sheet
Capacitor Enclosure Interior
Page 6
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
Baldor Start Switch Wiring