HySecurity MX3037R, MX3037, MX001457 Installation Instructions Manual

MX3037, MX3037R, MX001457
EXAMPLE
Smart DC Controller Installation Instructions
The following instructions are intended to assist the user in replacing the Smart DC Controller (SDC) in HySecurity electromechanical gate operators. Please read all assembly instructions before installing the kit.
REQUIRED TOOLS
 Phillips head screwdriver  Needle nose pliers
latest available version. The latest available version is at www.hysecurity.com/contact-us/technical-
support/operator-software/ or by naviagting the
HySecurity website by clicking:
TechSupport Resources  Operator Software Current Operator Software Versions
UL 325 - 2018 requires that gate operators monitor external entrapment protection sensors. Affects all HySecurity gate operators manufactured beginning in 2016.
CAUTION
Remember the operator may have unique user & installer menu settings on the existing board. Prior to replacing the SDC board, compare the programmed settings that appear in the existing board’s display to the default settings shown in the "Smart DC Controller Worksheet" on page 2 and note any changes. If you have a bi-parting gate system, be sure the software version in both operators is identical.
COPY USER & INSTALLER MENU SETTINGS
Examples of the settings that need to be reprogrammed when you replace an SDC board include: Build Year, Operator Type, Usage Class, Gate Handing and Learn Limits. Other settings may include Gate Weight, Close Timer, and
accessory congurations. The operator can be
reprogrammed on site by entering the User or Installer Menu via the Menu buttons or using S.T.A.R.T. software and a laptop PC to save/load existing settings. If you need more information, see "Technical Support" on page 1.
Create a backup copy of the gate operator
congurations, using one of two methods:
z Use a PC laptop and S.T.A.R.T. with a USB cable
(Type A to Type B).
z Use the "Smart DC Controller Worksheet" on
page 2. Go through each menu item and write the number that appears in the display into the chart’s column titled, “Display Setting.”
TWO METHODS TO RECORD USER & INSTALLER MENU SETTINGS
TECHNICAL SUPPORT
For technical support, call your installer or authorized HySecurity distributor. Obtain the serial number of your operator before calling. For the name of a distributor near you, contact HySecurity at 800-321-9947.
For more information regarding how HySecurity is handling monitoring of external entrapment protection sensors, go online to:
www.hysecurity.com/gatesafety
Figure 2. SDC Programmable Menu Items Settings
D0360 REV. I ©2018 SMART DC INSTALLATION INSTRUCTIONS www.hysecurity.com | 1
Figure 1. S.T.A.R.T. Display
User Menu Item* Default Setting Display Setting
CT _ Close Timer 0
HC _ Hold to Close 0
HO _ Hold to Open 0
AP _ AC Loss function 0
RO_ Radio Open/Close 0
BF _ Warn Before Operate 2
FA _ Forced Open Alert 0
DA _ Drift Close Alert 0
PE _ Photo Eye Alignment 0
CL_ Set Clock (24 hour) 0
LD_ LCD Contrast setting 5
CA_ Close Limit Adjustment 0
AL_ Flash on Close Limit 1
DS_ Diagnostic Log 0
*NOTE: The items shown in the user & installer menu charts may or may not appear on your operator’s display. The menu items that appear are dependent on the operator type
Installer Menu Item* Default Setting Display Setting
OT _ Select Operator Type 0
MN _ Model Number 0
LL _ Learn Limits 0
UC _ Usage Class 0
SH _ Gate Handing 0
WT _ Gate Weight (lbs) 0
LN _ Gate Length (Feet) 0
OS _ Open Speed 5
CS _ Close Speed 5
FD _ Load Factory Defaults 0
DG _ Dual Gate 0
SG _ Sequenced Gate 0
CH _ Charger Type 0
FO _ Fire Dept. Open 0
Smart DC Controller Worksheet
(write it down here)
(write it down here)
Notes:
SE _ IES Sensitivity 2
SS _ Inherent sensor Stop 0
LC _ Leaf Delay Close 0.0 Secs
LO_ Leaf Delay Open 0.0 Secs
RT _ Maximum Run Timer 30 Secs
PO _ Partial Open distance 0
EC _ Eye Close Logic 0
EO _ Eye Open Logic 0
GR _ Gate Edge Logic 0
SR _ IES Sensor Logic 1
PC _ Photo Eye Contact NC 0
GC _ Gate Edge Output NC 0
DT _ Disable Free Exit 0
OR _ Outside Obstr Loop 1
IR _ Inside Obstr Loop 1
HD _ Center Loop Hold 1
DL _ Detector Logic 1
CR _ RLD Reverse Open 0
CB _ RLD Disables ELD 0
CP _ Counts PBO 0
EB _ ELD Back off - Detector 0
R1 _ Relay 1 Logic - disabled 0
R2 _ Relay 2 Logic - Close Limit 1
TL _ Gate Open alert 2
LT _ Loitering alert 3
SA _ STC Address 0
ELD _ Exit Loop Set 0
ILD _ Inside Obstr. Loop Set 0
OLD _ Outside Obstr. Loop Set 0
CLD _ Center Loop Set 0
Installer Menu Item* Default Setting Display Setting
(write it down here)
Notes:
SMART DC CONTROLLER WORKSHEET
Table 1. User Menu
User Menu Item*
Default Setting
CT _ Close Timer 0
HC _ Hold to Close 0
HO _ Hold to Open 0
AP _ AC Loss function 0
RO_ Radio Open/Close 0
BF _ Warn Before Operate 2
FA _ Forced Open Alert 0
DA _ Drift Close Alert 0
PE _ Photo Eye Alignment 0
CL_ Set Clock (24 hour) 0
LD_ LCD Contrast setting 5
US_ Clear count 0
CA_ Close Limit Adjustment 0
AL_ Flash on Close Limit 1
DS_ Diagnostic Log 0
PD_ Set password 0
NOTE: Available menu items are dependent on operator type
and programming congurations or options.
Table 2. Installer Menu
Installer Menu Item*
BY _ Build Year
OT _ Select Operator Type 0
MN _ Model Number 0
S1_ Sensor 1 Type
S2_ Sensor 2 Type
S3_ Sensor 3 Type
LL _ Learn Limits 0
UC _ Usage Class 0
SH _ Gate Handing 0
WT _ Gate Weight (lbs) 0
LN _ Gate Length (Feet) 0
OS _ Open Speed 5
CS _ Close Speed 5
FD _ Load Factory Defaults 0
DG _ Dual Gate 0
1
See "Setting the Build Year" and Table 3 on page 5
2
Setting dependent on BY. S1, S2, S3 appear if BY is set to 2 or
higher. NOTE: Available menu items are dependent on operator type
and programming congurations or options.
1
1
1
1
Default Setting
Display Setting
Display Setting
0
0
0
0
Table 2. Installer Menu
Installer Menu Item*
Default Setting
SG _ Sequenced Gate 0
CH _ Charger Type 0
OC_Emergency Close 0
BT_ Battery type 0
FO _ Fire Dept. Open 0
DR_ Reversing Sensor 0
SE _ IES Sensitivity 2
SS _ Inherent sensor Stop 0
LC _ Leaf Delay Close 0.0 Secs
LO_ Leaf Delay Open 0.0 Secs
RT _ Maximum Run Timer 30 Secs
PO _ Partial Open distance 0
EC _ Eye Close Logic 0
EO _ Eye Open Logic 0
GR _ Gate Edge Logic 0
SR _ IES Sensor Logic 1
PC _ Photo Eye Contact NC
GC _ Gate Edge Output NC
2
2
0
0
DT _ Disable Free Exit 0
OR _ Outside Obstr Loop 1
IR _ Inside Obstr Loop 1
HD _ Center Loop Hold 1
DL _ Detector Logic 1
CR _ RLD Reverse Open 0
CB _ RLD Disables ELD 0
CP _ Counts PBO 0
EB _ ELD Back off - Detector 0
R1 _ Relay 1 Logic - disabled 0
R2 _ Relay 2 Logic - Close Limit 1
R3 -R10 Multiple Relay Logic 0
TL _ Gate Open alert 2
LT _ Loitering alert 3
BA_ Break Away (Arm only) 0
SA _ SDC Address 0
NE_ Network Address 0
ELD _ Exit Loop Set 0
ILD _ Inside Obstr. Loop Set 0
OLD _ Outside Obstr. Loop Set 0
CLD _ Center Loop Set 0
1
See "Setting the Build Year" and Table 3 on page 5
2
Setting dependent on BY. S1, S2, S3 appear if BY is set to 2 or
higher. NOTE: Available menu items are dependent on operator type
and programming congurations or options.
Display Setting
2 | www.hysecurity.com SMART DC BOARD INSTALLATION INSTRUCTIONS D0360 REV. I ©2018
TO SCREWS
ANDOFF
REPLACING THE SMART DC CONTROLLER
To replace a SDC board, take the following steps:
1. Back up (make a copy) of the existing board’s menu
settings. See "www.hysecurity.com/gatesafety" on page 1 and "Smart DC Controller Worksheet" on page 2.
2. Turn OFF power to the Control Box (both AC & DC
switches).See Figure 3.
3. Use tape to identify the various accessory connections and then disconnect all accessory cables attached to the board. See Figure 4.
4. Disconnect all harness connectors and any HY-5A or HY-5B vehicle loop detectors. Use needle nose pliers to crimp the HY-5A or HY-5B standoffs and then push the standoff through the mounting hole. See Figure 4.
5. Use a Phillips-head screwdriver to remove the seven screws from the board and three screws at the top of the control box. Set the Smart DC Controller board and the ten screws aside. See Figure 4.
6. Note the orientation of the replacement board and align the holes with the mounting standoffs. Secure the board using the screws removed in Step 5.
NOTICE
Tighten the three screws on top of the control
box rst, then tighten the remaining screws
that secure the board.
7. Reattach all accessories, harness connectors, and HY-5A or HY-5B vehicle detectors to their proper locations on the replacement Smart DC Controller board. Make sure all jumpers are wired correctly. See Figure 4.
DC POWER I/O
AC POWER I/O
Figure 3. Turn AC and DC Power On
P THREE
CONTROL BOX
Phillips Head Screws (7x)
CUT-AWAY VIEW
MOUNTING STANDOFF
SDC BOARD HY-5A or HY-5B
HY-5A or HY-5B
MOUNTING ST
HY-5A or HY-5B
HY-5A or HY-5B
MOUNTING STANDOFF
8. Turn ON the Control Box AC & DC power switches
(Figure 3), and then set the operator type and other parameters by following "Setting the Operator Type" on page 4.
Figure 4. Control Box - Cut-away view of the SDC
Board in a SwingSmart DC Operator
DANGER
Failure to select the correct operator type (OT) can result in gate operator malfunction which has the potential to cause serious injury or death due to the improper operation of the gate.
D0360 REV. I ©2018 SMART DC INSTALLATION INSTRUCTIONS www.hysecurity.com | 3