Flow Switch Upgrade Instructions
801220 - Rev. 1
HT400
Flow Switch Upgrade
Instructions
(P/N 801220)
Revision 1 June 2000
Hypertherm, Inc.
Hanover, NH USA
http://www.hypertherm.com
email:info@hypertherm.com
© Copyright 2000 Hypertherm, Inc.
All Rights Reserved
Hypertherm and HT are trademarks of Hypertherm, Inc.,
and may be registered in the United States and/or other countries
Hypertherm Offices Worldwide
Hypertherm, Inc.
Etna Road, P.O. Box 5010 Hanover, NH 03755 USA Tel.: (603) 643-3441 (Main Office) Fax: (603) 643-5352 (All Departments) Tel.: (800) 643-9878 (Technical Service – toll-free in USA and Canada) Tel.: (800) 737-2978 (Customer Service – toll-free in USA and Canada) email: info@hypertherm.com (General Information) email: service@hypertherm.com (Technical/Customer Services)
Hypertherm Plasmatechnik GmbH
Technologiepark Hanau Rodenbacher Chaussee 6 D–63457 Hanau-Wolfgang, Germany Tel.: 49 6181 58 2100 Fax: 49 6181 58 2134
Hypertherm (S) Pte Ltd
No. 19 Kaki Bukit Road 2 K.B. Warehouse Complex Singapore 417847 Tel.: 65 841 2489 Fax: 65 841 2490
Hypertherm UK Ltd
9 Berkeley Court, Manor Park Runcorn, Cheshire, England WA7 1TQ Tel.: 44 1928 579 074 Fax: 44 1928 579 604
:
France
15 Impasse des Rosiers 95610 Eragny, France Tel.: 33 1 30 37 15 28 Fax: 33 1 30 37 15 79
Hypertherm S.r.L.
Via Torino 2 20123 Milan, Italy Tel.: 39 02 725 46 312 (Customer Service) Tel.: 39 02 725 46 314 (Technical Service) Fax: 39 02 725 46 400 (All Departments)
Hypertherm B.V.
Burg, Haverkampstraat 13 7091 CN Dinxperlo, The Netherlands Tel.: 31 315 655 866 (Customer Service) Fax: 31 315 655 886
European Technical Support Organization (ETSO)
Edisonstraat 12 3281 NC Numansdorp, The Netherlands Tel.: 00 800 4973 7843 (00 800 Hypertherm) – (toll-free Technical Service) Tel.: 31 186 659494 Fax: 31 186 659495
Japan
Shinjuku Park Tower 30th Floor 3-7-1 Nishi-Shinjuku Shinjuku-ku, Tokyo 163-1030, Japan Tel.: 81 03 5326 3142 Fax: 81 03 5326 3001
5/00
Purpose
The HT400 flow switch upgrade instructions provide the necessary information to allow the removal of the existing flow switches and replacing them with the Kobold flow switch manifold subassembly.
Customer Supplied Tools
Drill 3/16" (0.187)/4.762mm drill bit Straight blade screwdriver 7/16" (11.11 mm) open-end wrench 9/16" (14.29 mm) open-end wrench 11/16" (17.46 mm) open-end wrench 1/4" (6.35 mm) hex wrench
Flow Switch Assembly Upgrade Kit (# 028484)
Part No. Description Qty.
029546 Kobold flow switch manifold SA 1
005139 Flow switch, 0.25 GPM 005140 Flow switch, 1.20 GPM 004456 Flow switch manifold 074005 Cable Tie 5 075040 M/S:10-32 X 5/8 3 075186 Lock washer:#10 Intl-T 3
HT400 FLOW SWITCHES
Procedure
Remove Existing Flow Switches
To remove the existing flow switches, refer to the following procedure and the figures called out from the HT400 Plasma Arc Cutting System Instruction Manual IM-54 (P/N 800540).
1. Shut the power supply down at the front panel and turn off power at the disconnect box.
2. Remove the top cover and the left side cover to access the flow switches on the center wall.
3. Remove the tyraps from around the flow switches leads which are connected to the terminal
4. Disconnect the 4 switch leads (red) from the terminal strip. These leads are marked 4 (2), 5,
5. Disconnect the input water hose (left side) from flow switch 2FLS (005053). Refer to Figure
Disconnect the gas supply to the power supply. Disconnect the water supply to the power supply.
Refer to Figure 38.
strip located on the opposite side of the wall..
and 6.
38. Disconnect the other end of the hose from the water manifold (top hose) at rear panel. Refer to Figure 39. Remove the plug from the upgrade kit and screw into the manifold where the hose was disconnected. Refer to Figure 1 in this upgrade instruction.
UPGRADE INSTRUCTIONS
Page 1
HT400 FLOW SWITCHES
6. Disconnect and tag the remaining hoses at the flow switches.
7. Remove the bolts, washers, and screws to remove the flow switches.
Install Upgrade Kit
To install the Kobold flow switch manifold subassembly upgrade kit, refer to Figures 1 and 2 and perform the following procedure.
1. Refer to Figure 1
2. On the side of the wall with the terminal strip, position the template as indicated. Remove any leads from the terminal strip that interfere with drilling.
3. Drill the three holes.
4. Align the three holes in the manifold (004456) with the holes on the wall.
5. On the terminal strip side of the wall, install the screws with lockwashers through the wall and into the manifold subassembly.
6. Route the flow switch leads to the terminal strip on the opposite side of the wall. Connect leads to the terminal strip as shown.
7. Replace ties to secure flow switch leads.
8. To connect the water hose assemblies, proceed as follows:
Connect the WATER IN hose assembly (024102) from the manifold at the rear panel
to the manifold (004456).
Connect the WATER OUT - ELECTRODE hose assembly (024138) to flow switch
1FLS (005140/1.20 GPM).
Connect the hose assembly (024139) from the WATER flow meter on the front panel to
flow switch 2FLS (005139/.25 GPM).
UPGRADE INSTRUCTIONS
Page 2
6-00
HT400 FLOW SWITCHES
Figure 1 Mounting Holes
Approximate hole locations
Drill 3/16" (0.187)/4.762mm Dia. Holes (3 places)
UPGRADE INSTRUCTIONS
Page 3
Flow Switch 2FLS (0.25 gpm) 005139
Flow Switch 1FLS (1.20 gpm) 005140
HT400 FLOW SWITCHES
Flow Switch Subassembly
Attach manifold to center wall with mount­ing screws and washers from far side of wall.
Mounting Screw Holes
WATER IN Hose 024102
WATER OUT­ELECTRODE Hose 024138
Rear Panel
(3)
Manifold 004456
WATER Flow Meter Hose 024139
Flow Switch Leads (4)
Terminal Strip
Plug 015561
Manifold
Figure 2 HT400 Upgrade Kit Installation