Hypertherm Automation Family Application Note

Update XPR Firmware through Phoenix over EtherCAT
Application Note
810720 | Revision 1 | November 2020
Hypertherm Europe B.V.
Vaartveld 9, 4704 SE Roosendaal, Nederland 31 165 596907 Tel 31 165 596901 Fax 31 165 596908 Tel (Marketing)
31 (0) 165 596900 Tel (Technical Service) 00 800 4973 7843 Tel (Technical Service)
technicalservice.emea@hypertherm.com (Technical Service Email)
Hypertherm (Shanghai) Trading Co., Ltd.
B301, 495 ShangZhong Road Shanghai, 200231 PR China 86-21-80231122 Tel 86-21-80231120 Fax
86-21-80231128 Tel (Technical Service)
techsupport.china@hypertherm.com (Technical Service Email)
South America & Central America: Hypertherm Brasil Ltda.
Rua Bras Cubas, 231 – Jardim Maia Guarulhos, SP – Brasil CEP 07115-030 55 11 2409 2636 Tel tecnico.sa@hypertherm.com (Technical Service Email)
Hypertherm Korea Branch
#3904. APEC-ro 17. Heaundae-gu. Busan. Korea 48060 82 (0)51 747 0358 Tel 82 (0)51 701 0358 Fax Marketing.korea@hypertherm.com (Marketing Email) TechSupportAPAC@hypertherm.com (Technical Service Email)
Hypertherm Pty Limited
GPO Box 4836 Sydney NSW 2001, Australia 61 (0) 437 606 995 Tel 61 7 3219 9010 Fax au.sales@Hypertherm.com (Main Office Email) TechSupportAPAC@hypertherm.com (Technical Service Email)
Hypertherm (India) Thermal Cutting Pvt. Ltd
A-18 / B-1 Extension, Mohan Co-Operative Industrial Estate, Mathura Road, New Delhi 110044, India 91-11-40521201/ 2/ 3 Tel 91-11 40521204 Fax HTIndia.info@hypertherm.com (Main Office Email) TechSupportAPAC@hypertherm.com (Technical Service Email)
Hypertherm, Inc.
Etna Road, P.O. Box 5010 Hanover, NH 03755 USA 603-643-3441 Tel (Main Office) 603-643-5352 Fax (All Departments) info@hypertherm.com (Main Office Email)
800-643-9878 Tel (Technical Service)
technical.service@hypertherm.com (Technical Service Email)
800-737-2978 Tel (Customer Service)
customer.service@hypertherm.com (Customer Service Email)
866-643-7711 Tel (Return Materials Authorization) 877-371-2876 Fax (Return Materials Authorization)
return.materials@hypertherm.com (RMA email)
Hypertherm México, S.A. de C.V.
Avenida Toluca No. 444, Anexo 1, Colonia Olivar de los Padres Delegación Álvaro Obregón México, D.F. C.P. 01780 52 55 5681 8109 Tel 52 55 5683 2127 Fax Soporte.Tecnico@hypertherm.com (Technical Service Email)
Hypertherm Plasmatechnik GmbH
Sophie-Scholl-Platz 5 63452 Hanau Germany 00 800 33 24 97 37 Tel 00 800 49 73 73 29 Fax
31 (0) 165 596900 Tel (Technical Service) 00 800 4973 7843 Tel (Technical Service)
technicalservice.emea@hypertherm.com (Technical Service Email)
Hypertherm (Singapore) Pte Ltd.
82 Genting Lane Media Centre Annexe Block #A01-01 Singapore 349567, Republic of Singapore 65 6841 2489 Tel 65 6841 2490 Fax Marketing.asia@hypertherm.com (Marketing Email) TechSupportAPAC@hypertherm.com (Technical Service Email)
Hypertherm Japan Ltd.
Level 9, Edobori Center Building 2-1-1 Edobori, Nishi-ku Osaka 550-0002 Japan 81 6 6225 1183 Tel 81 6 6225 1184 Fax HTJapan.info@hypertherm.com (Main Office Email) TechSupportAPAC@hypertherm.com (Technical Service Email)
© 2020 Hypertherm, Inc. All rights reserved.
XPR, EDGE, EDGE Connect, Phoenix, and Hypertherm are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. EtherCAT is a trademark of Beckhoff Automation. All other trademarks are the property of their respective holders.
Environmental stewardship is one of Hypertherm’s core values, and it is critical to our success and our customers’ success. We are striving to reduce the environmental impact of everything we do. For more information:www.hypertherm.com/environment.

Introduction

You can update XPR firmware automatically through Phoenix 10.13 and later if your XPR’s main control board already has firmware version M or later installed. XPR firmware version N or later is required.
Update XPR Firmware through Phoenix over EtherCAT
Update XPR Firmware through Phoenix
over EtherCAT
In Phoenix 10.13 and later, you can:
Automatically check for and install XPR firmware updates. Automatic firmware updates are
enabled by default on Image 50 in production, new CNCs or CNCs updated with Image 50.
Disable/enable automatic firmware updates with a password.
Check for XPR firmware updates with a password.
Manually install XPR firmware during troubleshooting (Not recommended).
For general and troubleshooting information, refer to Frequently asked questions (FAQs) on page 8.

Before you begin

The procedures in this document will not work unless all of the following conditions are met:
Phoenix 10.13 or later must be installed on your CNC with the EDGE Connect Suite
Installer.
Automatic firmware updates are turned on with the password.
At least one XPR is selected on the Station Configuration screen in Phoenix.
To update firmware from version L to M or to install XPR web interface firmware, refer to Hypertherm Field Service Bulletin 809820.
The XPR’s remote on-off switch is in the ON position.
Firmware revision M or later is already installed on the XPR main control board. To check
the current firmware version, refer to page 8.
If you need to avoid updating the firmware on a specific XPR while
updating the firmware on other XPRs, take that XPR out for service.
EDGE Connect Application Note 810720 3
Update XPR Firmware through Phoenix over EtherCAT
To apply the updates now, click OK.
To apply the updates later, click Cancel and
repeat this procedure when you are ready.
The time estimate varies based on the number
of XPRs, files, and types of files with updates available.

Automatically update firmware

After you complete the “Before you begin” steps on page 3, Phoenix checks for XPR firmware updates upon launching by default.
1. Start Phoenix 10.13 or later.
2. A “Checking for firmware updates. Please wait...” dialog displays.
If no further dialogs display, then firmware updates are not available. Continue with your
standard cutting operations. If you would like to see a confirmation that no firmware updates are available, refer to Check for firmware updates on page 5.
If an XPR is out for service, you are prompted to put the XPR back in service before
continuing. If you do not want to update that XPR’s firmware, keep the XPR out for service.
3. If firmware updates are available, a dialog shows the firmware to update and the approximate time needed to complete the updates.
The XPR Web Interface firmware cannot be updated without a wireless connection or USB.
Refer to Hypertherm Field Service Bulletin 809820.
4. To view progress toward completion during the firmware update process, review the status messages that appear in blue font in the lower-left corner of the Phoenix Main screen.
5. On the “Firmware Updates Complete” dialog, choose OK to restart the network and continue with standard cutting operations.
6. To review installed firmware versions, refer to the XPR Diagnostics view. See page 8.
4 810720 Application Note EDGE Connect

Disable/enable automatic firmware updates

Automatic firmware updates are enabled by default on Image 50 in production, new CNCs or CNCs updated with Image 50. Phoenix automatically checks for available XPR firmware updates each time that Phoenix launches. You can disable and enable this feature, as needed.
Disable automatic firmware updates
To prevent Phoenix from automatically checking for firmware updates:
1. On the Main screen in Phoenix, select Setups > Password.
2. Typ e DISABLEAUTOFOE.
After disabling automatic firmware updates, Phoenix does not check for or apply firmware updates again unless you take either of the following actions:
Check for firmware updates manually with a password.
Enable automatic firmware updates with a password.
Update XPR Firmware through Phoenix over EtherCAT
Updating an EDGE Connect with the EDGE Connect Suite Installer does NOT re-enable automatic firmware updates.
Enable automatic firmware updates
If automatic firmware updates have been disabled, use the ENABLEAUTOFOE password to re-enable automatic firmware updates. See below.
1. On the Main screen in Phoenix, select Setups > Password.
2. Typ e ENABLEAUTOFOE.
3. Restart Phoenix and follow the steps to Automatically update firmware on page 4.

Check for firmware updates

At any time, you can use the following password to find out if the XPRs on your EtherCAT network have the latest firmware that is compatible with your current version of Phoenix.
1. On the Main screen in Phoenix, select Setups > Password.
2. Typ e CHECKFOEUPDATES. If needed, the fieldbus network starts automatically.
If firmware updates are NOT available, then a “No updates found” dialog displays. If firmware updates are available, go to step 3 on page 4.
EDGE Connect Application Note 810720 5
Update XPR Firmware through Phoenix over EtherCAT
The XPR Web Interface firmware files are not selected in the example above because
these files cannot be updated over EtherCAT. If you select to update the XPR Web Interface firmware, those files are not sent to the XPR and errors do not display.
The EDGE Connect Suite Installer saves the latest compatible XPR firmware files at
the following location on your CNC: C:\Program Files (x86)\Hypertherm\Firmware\XPR. To roll back to an older version of XPR firmware manually, replace the files in this location. Hypertherm recommends that you do not rename the files. Use the default file names as a best practice.
If an XPR is out for service, you are prompted to put the XPR back in service before
continuing. If you do not want to update that XPR’s firmware, keep the XPR out for service.

Manually update firmware (advanced)

CAUTION
The manual update method allows you to install incompatible firmware files which may prevent the XPR from operating. Hypertherm recommends using the automatic method of updating firmware (on page 4) to make sure that all of the latest compatible firmware is installed.
The following manual method of updating firmware over EtherCAT is only intended for use by advanced users who need to do either of the following troubleshooting tasks:
Install an older version of firmware
Update firmware on a single XPR component
1. On the Main screen in Phoenix, choose Setups > Passwords.
2. Typ e FOEUPDATE and then choose OK.
3. In the file selection dialog, select all firmware (*.bin) files that you want to update on all available
XPRs. Hypertherm recommends that you update all firmware files at once.
6 810720 Application Note EDGE Connect
Update XPR Firmware through Phoenix over EtherCAT
To apply the updates now, click OK.
To apply the updates later, click Cancel and
repeat this procedure when you are ready.
The time estimate varies based on the number
of XPRs, files, and types of files with updates available.
4. Click Open and then wait while the Fieldbus Network resets.
5. A dialog shows the firmware to update and the approximate time needed to complete the
updates.
6. During the firmware update process, look for the blue status messages in the lower-left corner of the Phoenix Main screen to view progress toward completion.
7. On the “Firmware Updates Complete” dialog, choose OK to restart the network and continue with standard cutting operations.
8. To review firmware versions after the update, refer to the XPR Diagnostics view. See page 8.
To roll back to an older version of XPR Firmware manually, copy the firmware files to
C:\Program Files (x86)\Hypertherm\Firmware\XPR and repeat this procedure.
EDGE Connect Application Note 810720 7
Update XPR Firmware through Phoenix over EtherCAT

Frequently asked questions (FAQs)

This section provides answers to general and troubleshooting questions about updating plasma supply firmware with the File over EtherCAT (FOE) method.
General
Does my cutting system support firmware updates over EtherCAT?
Your XPR supports firmware updates over EtherCAT if the main control board on the XPR has version M firmware or later installed.
To find out which PCB firmware versions are installed on your XPR cutting system:
1. On the Main screen in Phoenix, select Setups > Diagnostics > XPR System.
2. From the XPR Diagnostics view, select a Station number.
3. Select the Other tab.
If the XPR Main Control board is currently at revision L or earlier, use a wireless connection or USB to update firmware to revision M or later. Refer to Hypertherm Field Service Bulletin 809820.
Once your XPR firmware is at revision M or later, you can apply most firmware updates through Phoenix with the procedure on page 4.
What is included in a firmware update?
The automatic firmware update method on page 4 installs the latest XPR firmware that is compatible with your current version of Phoenix. All XPR firmware, except for the Web Interface firmware, is included.
To find out which version of XPR firmware is included with a specific version of Phoenix bundled in the EDGE Connect Suite Installer, refer to the Phoenix Release Notes (809720).
8 810720 Application Note EDGE Connect
How long does the firmware update process take?
The duration of the update depends on the files, file sizes, and number of XPRs with updates available.
Before you apply firmware updates over EtherCAT, a dialog provides an estimate of the time needed to complete the updates.
Do I have to install all available firmware updates?
Hypertherm recommends applying all available firmware updates automatically with the procedure on page 4. When firmware automatic updates are enabled, you cannot select which firmware files to update. You must either apply all available updates or none of them.
In troubleshooting scenarios only, Hypertherm Technical Services and OEMs may install XPR firmware manually. Refer to page 6.
Troubleshooting
What happens if I cancel the update process part way through?
In the event that any single firmware file is only partially installed when the update process is canceled, the system automatically reverts back to using the file that was in use prior to attempting the update.
Update XPR Firmware through Phoenix over EtherCAT
If you canceled the updates before completion, repeat the update process to install the remaining updates.
Why don’t I see a prompt to install firmware updates?
The prompt to install firmware updates does not display when:
XPR firmware is already up-to-date. To verify that no firmware updates are available
to install, refer to page 5.
Automatic firmware updates are enabled, but the criteria in the “Before you begin”
section on page 3 are not satisfied.
Automatic firmware updates are disabled. To enable automatic firmware updates,
refer to page 5.
If you continue to have problems updating firmware over EtherCAT, you can:
Apply firmware updates with a wireless connection or USB instead. Refer to
Hypertherm Field Service Bulletin 809820.
Contact your OEM or Hypertherm Technical Services for advanced troubleshooting
help. See Manually update firmware (advanced) on page 6.
EDGE Connect Application Note 810720 9
Update XPR Firmware through Phoenix over EtherCAT
10 810720 Application Note EDGE Connect