ABOUT THIS DOCUMENT
This document pertains to installation of the Hyperion Gateway (IDS­CCULD). Before installation, please familiarize yourself with this installation guide and review the Hyperion User Guide to understand system configuration and setup. Supporting documentation can be found in the Wren Support Portal at www.wrensolutions.com/support.
PRODUCT MODIFICATIONS
This product is to be installed and used for the specific purpose for which it was designed. It is not to be modified or serviced by anyone other then Wren. Unauthorized changes or modifications to the product will result in the warranty being voided and could possibly invalidate regulatory certifications.
WARRANTY
Unless otherwise noted, all products are covered by Wren's Standard Limited Manufacturer's Warranty as set forth in the current version of Wren's Terms and Conditions
INTELLECTUAL PROPERTY RIGHTS
Wren maintains certain intellectual property rights that may pertain to this product. To see a list of our patents, please refer to our
TRADEMARK ACKNOWLEDGMENTS
Wren®. the Wren logo, Hyperion® and the Hyperion logo are trademarks of Wren. The trademarks that are followed by ® are registered trademarks in the U.S. All other trademarks and/or registered trademarks mentioned herein are properties of their respective owners and are for reference purposes only. The use of such third party trademarks does not indicate any affiliation with or sponsorship of or by Wren. All rights reserved.
NOTICES
RF Exposure for FCC WARNING: To satisfy FCC RF exposure requirements for mobile
transmitting devices, a separation distance of 31 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
RF Exposure for IC WARNING: To satisfy IC RF exposure requirements for mobile
transmitting devices, a separation distance of 44 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
AVERTISSEMENT: Pour satisfaire IC RF exigences d’exposition pour
les appareils mobiles de transmission, une distance de séparation de 44
cm ou plus doit être maintenue entre l’antenne de cet appareil et des personnes pendant le fonctionnement de l’appareil. Pour assurer la
conformité, les opérations au plus près que cette distance ne sont pas recommandés. L’antenne utilisée pour cet émetteur ne doit pas être situé en conjonction avec une autre antenne ou émetteur.
(800) 881-2249
EXTENSION 4
PRODUCT SUPPORT
For comprehensive product support including manuals, FAQs and
troubleshooting, visit our customer support portal
WWW.WRENSOLUTIONS.COM/SUPPORT
Page 3
Hyperion Gateway Installaon Guide
www.wrensolutions.com
7L776 Rev A 190510
Prior to installation, verify that all hardware is included. If there are missing components, please contact Wren.
COMPONENT LIST
Hyperion Gateway 24VDC Power Supply Mounting Bracket
Antenna (x2)
REQUIRED TOOLS AND ACCESSORIES
#2 Phillips screwdriver Drill
Cables (CAT5 or higher)
DEVICE OVERVIEW
1. SD Card Slot
2. Hyperion Device Ports
3. Digital Input/Output
4. Audio Out
2 3 4 5 6 7 8 9
10
1
NOTE: CABLING SHOULD MEET THE T-568A WIRING STANDARD AND ALL CABLES SHOULD BE TESTED BEFORE USE.
IMPROPER CABLING COULD DAMAGE THE GATEWAY AND VOID PRODUCT WARRANTY
5. Hyperion Radio Antenna
6. Audio Channel Volume Control
7. DC Power Input
8. Network Connection
9. USB Potts
10. Wi-Fi Antenna
Hardware
24VDC
Page 4
Hyperion Gateway Installaon Guide
www.wrensolutions.com
7L776 Rev A 190510
BEFORE BEGINNING INSTALLATION, PLEASE
MAKE SURE OF THE FOLLOWING:
YOU HAVE READ THE INSTALLATION GUIDE
YOU HAVE READ THE USER GUIDE
YOU ARE ONLY USING THE HYPERION POWER SUPPLY
YOU HAVE TESTED AND CERTIFIED ALL CABLE CONNECTIONS
FOR PROPER PINOUT ALIGNMENT PER T-568A STANDARD
IMPROPER CABLING COULD DAMAGE THE
GATEWAY AND VOID PRODUCT WARRANTY
Page 5
Hyperion Gateway Installaon Guide
www.wrensolutions.com
7L776 Rev A 190510
IDENTIFY AN APPROPRIATE MOUNTING LOCATION
1
Table Mount
The Gateway is equipped with rubber feet pre-installed for table mounting applications. If table mounting, the wall bracket will not be needed.
Wall Mount
The Gateway should be mounted to a structurally solid wall surface using the included bracket. Mount by using the appropriate fasteners and anchors for the mounting surface. (Fasteners and anchors are not provided).
3
CONNECT ETHERNET
NOTE: NETWORK CONNECTIVITY IS REQUIRED FOR
CUSTOM CONFIGURATION, BUT NOT REQUIRED FOR THE GATEWAY TO OPERATE.
Connect the Ethernet cable to the provided Ethernet network socket as depicted to the right.
4
CONNECT HYPERION DEVICES
Before connecting cables from devices, refer to the Gateway Configuration Plan to ensure Hyperion devices are plugged into their respective ports.
For Gateways that were not factory-configured, please complete the Gateway Configuration Plan before making any connections.
NOTE:
THESE ARE NOT ETHERNET PORTS
ENSURE THAT ALL CABLING CONNECTIONS HAVE BEEN CERTIFIED BEFORE
ATTACHING TO THE GATEWAY
IMPROPER CABLING COULD DAMAGE THE GATEWAY AND VOID PRODUCT
WARRANTY
CABLES RUNS HOULD NOT EXCEED 300 FEET
2
NOTE:
THE LONGER ANTENNA CONNECTS TO THE “HYPERIONJACK
FOR BEST RESULTS, THE ANTENNA SHOULD BE POINTED
AS VERTICALLY AS POSSIBLE
CONNECT ANTENNAS
Hand-tighten the appropriate antenna to the corresponding jack until snug.
Do not over-tighten.
Page 6
Hyperion Gateway Installaon Guide
www.wrensolutions.com
7L776 Rev A 190510
CONNECT DIGITAL INPUT AND OUTPUT RELAY
5
6
CONNECT AUDIO
Digital Input
The Digital Input can be used for connecting external devices to the Gateway. It is activated when a ground signal is sensed.
Output Relay
For connecting external devices, such as LEDs or sirens.
It can be wired as Normally Open or Normally Closed
The Relay is rated for 250VAC/100VDC, 10 amps
The gateway supports two, independent audio channels, each with separate connection ports and volume adjustment.
Attach speaker wires to the Gateway, making sure to note polarity.
To adjust volume, use a Philips screwdriver and turn the potentiometer accordingly. Volume can also be adjusted via the gateway software. More information can be found in the Gateway User Guide.
NOTE: WE RECOMMEND USING 18 AWG WIRE OR LARGER AND A MAXIMUM
RUN OF 500 FEET IN ORDER TO MAINTAIN AUDIO VOLUME AND CLARITY
NOTE: DO NOT APPLY ANY VOLTAGE TO THE DIGITAL INPUT OR DAMAGE WILL
OCCUR TO THE DEVICE, WHICH IS NOT COVERED UNDER WARRANTY
7
CONNECT POWER
Connect 24VDC from the supplied power supply to the power jack. Power can be confirmed by observing the green power light next to the power jack.
NOTE: ONLY USE THE SUPPLIED 24VDC POWER SUPPLY
OR IMPROPER POWER MAY BE APPLIED TO THE GATEWAY WHICH COULD NEGATIVELY AFFECT PERFORMANCE.
REFER TO GATEWAY CONFIGURATION
PLAN FOR SYSTEM TESTING
8
SYSTEM TEST
Loading...