Hyon HR1900P Installation And Operational Manual

RF Repeater
Installation and Operational Manual
(Model: HR1900P)
JAS Teletech
Table of Contents
1. General Information
1.1 Introduction
1.2 Specifications
1.3 Description
2. Installation
2.1 Introduction
2.2 Unpacking and Inspection
2.3 Preparation for Use
2.4 Before Installation
2.5 Antenna Installation
2.6 Repeater Installation
2.7 Connectors
2.8 Installation Example
3. Operation
3.1 Introduction
3.2 Operating Instructions
4. Trouble Shooting
5. Drawings
1. General Information
1.1 Introduction
This manual provides information pertaining to the installation and operation of JAS
Teletech’s HR1900P Home Repeater. This Unit is for CDMS, GSM, and TDMA
modulations in the PCS frequencies as shown in Table 1-1.
<Tebla 1-1: HR1900P>
Model Number
Down Link*
Frequencies
Up Link**
Frequencies
Modulation
HR-1900P 1930~1960MHz 1850~1910MHz CDMA, GSM, TDMA
* Down Link: signal from base station to mobile
** Up lInk: signal from mobile to base station
1.2 Specifications
<Table 1-2: HR1900P Specifications>
Specifications
No
.
Parameters
Downlink Uplink
Remarks
1
Frequency Range
1930~1990MHz 1850~1910MHz 60MHz B.W
2 Output Power +7dBm /1FA[Max.]
3 Gain 50dB ±2dB/Fc
4 Gain Flatness ≤ 7dB
Fc +885KHz
-45dBc/30KHz
Fc -885KHz
-45dBc/30KHz
Fc +1.98MHz
-50dBc/30KHz
5
In Band Spurious
Fc -1.98MHz
-50dBc/30KHz
6
Out OF Band Spurious
Less than
-13dBm/1MHz
-13dBm
7 P1dB
+14dBm
8 Output IP3
+24dBm
9
Down/Up Link shutdown Function
9dBm
10 Noise Figure 7dB @ Full Band
11 V.S.W.R 1 : 2.0 Up/Down Link Port
12 Impedance 50
13 Operating Temperature 0 ~ +50℃℃
14 Dimension (W x H x D) 120mm x 97mm x 43mm [Max.] Without Connector
15 Weight 600 g
16 RF Connector SMA-Type (Female) Up/Down Link Port