HydroTherm UMHWX3-1 User's Information Manual

UMHWX3-1
22-UMHWX3
TO THE INSTALLER: THIS MANUAL IS THE PROPERTY OF THE OWNER AND MUST BE AFFIXED NEAR THE
BOILER FOR FUTURE REFERENCE.
TO THE OWNER: THIS BOILER SHOULD BE INSPECTED ANNUALLY BY A QUALIFIED SERVICE AGENCY.
HWX GAS BOILERS
USER’S INFORMATION MANUAL
W ARNING: If the information in this manual is not f ollo wed e xactly, a fire or explosion ma y result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch. Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier .
BASIC OPERATION
A. General. This water boiler is a natural draft appli-
ance and is equipped with controls for proper opera­tion. All controls must be in proper working order. Contact a qualified service agency to provide annual maintenance as specified in Installation, Operation and Maintenance Manual.
1. Limit. See Figure 1. A de vice which automati- cally interrupts boiler operation when the water temperature exceeds the set point. Maximum allowable temperature is 240°F (115°C).
Original equipment with this boiler is a Honeywell L8148E1182. Boiler operation is interrupted when system temperature reaches cut-out temperature. Boiler operation resumes automatically when system temperature falls approximately 15°F (8°C) below the cut-out temperature. See also Figures 4 and 5 for limit sequence of operation.
2. Flame Rollout Switch.See Figure 1. A de vice which automatically interrupts boiler operation when flames or excessive heat are present in the combustion area. The control is a single use device. If the control is activated to interrupt boiler operation, do not attempt to place boiler in operation. Contact a qualified service agency.
3. Blocked Vent Switch (Vent Safety Shutoff Switch). See Figure 1. A device which auto­matically interrupts boiler operation when there is a blockage in the vent pipe or chimney. The control is a manual reset device. The control is located on the draft hood relief opening. If the control was activated to interrupt boiler opera­tion, do not attempt to place boiler in operation. Contact a qualified service agency.
4. Pilot.The pilot provides the ignition source for the main burners. Your boiler has a standing (continuous) pilot or an intermittent pilot. The intermittent pilot ignites only when there is a call for heat and extinguishes when the call f or heat ends. See Figures 6 and 7.
5. Gas Valve.The gas valve monitors pilot flame and regulates gas flow to the burners and pilot. See Figure 1.
6. Safety Relief Valve. A device which protects the boiler against excessive pressure . The saf e­ty relief valve can discharge a large amount of hot water - the installer should provide piping to discharge water near floor at a floor drain. If the safety relief valve discharges water, follow instructions TO TURN OFF GAS TO APPLI­ANCE (see Figure 2 or 3), and contact a quali­fied service agency .
Figure 1: Control Locations
B. Instructions to place boiler in operation and to turn
off the boiler are shown on the Operating or Lighting Instruction Label posted on the left side of the boiler. The instructions are also shown in Figures 2 and 3.
C. The Sequence of Operation is shown in Figures 4
and 5.
WARNING
CAUTION
Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency.
Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.
Do not use this boiler if any part has been under water. Immediately call a qualified service agency to inspect the boiler and to replace any part of the control system and any gas control which has been under water.
HWX USER’S INFORMATION MANUALPAGE 2
Figure 2: Intermittent Ignition Operating Instructions
HWX USER’S INFORMATION MANUAL PAGE 3
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electric switch; do not use any phone in your building.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat or operating control to lowest setting.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to slide the gas control switch. Never use tools. If the switch will not slide by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
5. If the gas valve is not visible, remove control access panel.
6. If the gas control switch is not in the "OFF" postion, slide the switch to "OFF".
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat or operating control to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. If the gas valve is not visible, remove the control
7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.
8. Slide the gas control switch to "ON".
9. Replace control access panel, if applicable.
10. Turn on all electrical power to the appliance.
11. Set thermostat or operating control to desired setting.
12. If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.
access panel.
4. Slide the gas control switch to "OFF".
5. Replace control access panel, if applicable.
SV9501/SV9601 9318 REV 3