Hydrotech ProSelect R1P Remote Water Chiller User Manual

1
ProSelect
WATER FILTRATION
Under Sink Chiller Unit
Installation Instructions and Use and Care Guide
For questions about features, suggested retail price, operation/performance, parts, accessories or service, call: 1-800-950-3226.
Or visit our website at: www.oasiswatercoolers.com
Unidad enfriadora bajo el fregadero
Instrucciones de instalacion y guia de usos y cuidados
Preguntas sobre sus caracteristicas, precio de venta sugerido, operacion/rendimiento, partes, accesories o servicio, llame al 1-800-950-3226.
O visite nuestra pagina en Internet www.oasiswatercoolers.com
This chiller is not a water purifier. Use with the ProSelect™ under the sink modular system that includes three types of filter units and a choice of faucets sold separately.
Esta unidad refrigeradora no es un purificador de agua. Debe ser utilizada con el sistema ProSelect™ de purificacion modular para instalas debajo de fregaderos con tres tipos de filtros y distintos modelos de grifos que se venden por separado.
Certified to
NSF/ANSI 61
Certificado al NSF/ANSI 61
System tested and certified against NSF/ANSI Standard 42 and 53 for the reduction of the claims specified on the Performance Data Sheet.
Sistema evaluado y certificado para les estandaras 42 y 53 de NSF/ANSI de reducción coma se especina en la hoja de especificationes de rendimiento.
When sold with Pro1 and Pro2 system.
Si vendido con los sistemas Pro1 y Pro2.
Table of Contents/Indice...................2
2
Table of Contents
CHILLER SAFETY .........................................................2
ASSISTANCE OR SERVICE ............................................3
INSTALLATION REQUIREMENTS...................................3
Tools and Parts.......................................................3
Addendum for R1P Chiller Installation ....................4
Location Requirements ...........................................5
Electrical Requirements...........................................5
Water Supply Requirements ....................................6
INSTALLATION INSTRUCTIONS....................................6
Install the Chiller ....................................................6
CHILLER USE...............................................................7
Setting the Control .................................................7
Draining the Chiller.................................................7
Reconnecting the Chiller .........................................7
BEFORE CALLING FOR SERVICE ...................................7
TROUBLESHOOTING....................................................8
CHILLER WARRANTY...................................................8
Índice
Chiller Safety
SEGURIDAD DEL ENFRIADOR.......................................1
ASISTENCIA O SERVICIO .............................................2
EXIGENCIAS PARA LA INSTALACIÓN............................2
Herramientas y materiales ......................................2
Requisitos para el lugar de la instalación ................3
Requisitos con respecto a la electricidad.................3
Exigencias del sumioistro de agua ..........................4
INSTRUCCIONES DE INSTALACIÓN ..............................4
Instalando el enfriador............................................4
USO DEL ENFRIADOR..................................................5
Fijando el control....................................................5
Vaciando el enfriador..............................................5
Reconectando el enfriador ......................................5
ANTES DE SOLICITAR SERVICIO...................................5
PROBLEMAS................................................................6
GARANTIA DEL ENFRIADOR ........................................7
DANGER
WARNING
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:
You can be killed or seriously injured if you don’t immediately
follow
instructions.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed.
3
Assistance or Service
Installation Requirements
Tools and Parts
Tools Needed
• Pencil • Measuring Tape
• Utility knife
Parts Supplied
Dealer Name _________________________________________________________________________________________________________
Address ______________________________________________________________________________________________________________
Phone Number _________________________________ Model Number ___________________________________________________
Purchase Date _______________________________________________________________________________________________________
If you need assistance or service, first see “Troubleshooting” section. Additional help is available by calling 1-800-950-3226. Monday to Friday 8:00 am ­6:00 pm (EST) or write:
Oasis Corporation P.O. Box 13150 Columbus, OH 43213-0150
Please include a daytime phone number in your correspondence.
For installation and service, call: 1-800-950-3226 or visit our website at www.oasiswatercoolers.com.
Keep this book and your sales slip together for future reference. You must provide proof of purchase or installation date for in-warranty service.
Write down the following information about your appliance to help you obtain assistance or service if you need it. You will need to know your complete model number. You can find this information on the model and serial number label.
IMPORTANT:
Observe all governing codes and ordinances. Check location where the chiller will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with installation specifications and with state and local plumbing codes.
Water connections use easy to connect fittings that do not require sealing compounds to keep them from leaking.
1. Under sink Chiller unit
2. 4 feet of blue tubing
3. 2 easy to connect elbows
4. 2 “T” quick connect fittings
5. Check valve
6. 4 feet of white tubing
7. 1 wall mounting clip
8. 1 phillips screws #7
4
Addendum for R1P Chiller Installation with
under-the-sink RO Connection
OPERATING INSTRUCTIONS
Since reverse osmosis (RO) systems have certain pressure minimums for operation, these override the minimum requirements stated in the Use and Care Guide for the chiller. The operating pressure for the chiller must not exceed 100 psi.
INSTALLATION INSTRUCTIONS
1. Connect the chiller after the last filter as shown in the Use and Care Guide. This is generally after the bladder tank. See the schematic below. Make sure that the outlet of the chiller leads directly to the inlet of the faucet as shown on page 4 of the Use and Care Guide. NOTE: The extremely cold water may cause condensation on the outside of the faucet during use. This is normal and will not hurt the faucet.
2. You do not need to use the pressure relief check valve configuration (parts 12 and 13 of the parts listed) shown in the manual as long as water from the chiller can freely flow backwards through the filter to the bladder tank. If you are uncertain whether this can happen, connect the check valve across the filtration set as shown in the Use and Care Guide.
5
Location Requirements
IMPORTANT: Faucet is sold separately and requires a 1-3/8” (3.5cm) diameter opening in sink or countertop. Spout can be
installed in place of sink spray hose. If faucet is not to be installed in sink spray hose opening, it is recommended that a qualified installer be contacted to drill a hole through your type of sink or countertop. Thickness of countertop at the hole must not exceed 1-3/4” (4.4cm).
For best performance, allow a 2” (5cm) space around the side and the top. Do not put any objects on top of the chiller that could obstruct the fan.
1. Chiller unit
2. Blue tubing included with chiller
3. Faucet is required (sold separately)
4. Cold water supply line
5. White tubing included with faucet
6. Dual filtration (sold separately)
7. Unit C (sold separately)
8. Flow monitor included with faucet.
9. “T” water line connector included with faucet
10. White “water in” collet
11. Blue “water out” collet
12. “T” quick connect
fitting
13. Check valve
Electrical Requirements
A 120-volt, 60 Hz, 15- or 20-amp, grounded electrical supply is required. It is recommended that a separate circuit serving only your chiller unit be provided. Use an outlet that cannot be turned on/off by a switch.
Recommended Ground Method
The chiller must be grounded. This appliance is equipped with a power supply cord with a 3 prong ground plug. To minimize possible chock hazard, the cord must be plugged into a mating 3 prong, ground-type outlet, grounded in accordance with all national and local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3 prong outlet installed by a qualified electrician.
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Failure to follow these instructions can result
in death, fire or electrical shock.
WARNING
Loading...
+ 11 hidden pages