IT IS VERY IMPORTANT THAT THOSE RESPONSIBLE FOR
THE INSTALLATION OF THIS EQUIPMENT, AS WELL AS THE
OWNER/OPERATOR, READ THIS MANUAL AND CAREFULLY
FOLLOW THE INSTRUCTIONS AND GUIDELINES.
Page 2
Page 3
Table of Contents
Important Safety Instructions...................................................................................................................... 3
Installing the Disinfection Unit................................................................................................................... 8
Mounting Electrical Control Box................................................................................................................ 9
Installing the UV Lamp .......................................................................................................................10-10
Pre-Start Up Sequence .............................................................................................................................. 12
Parts List ................................................................................................................................................... 18
CAUTION! Use disinfection unit only for its intended purpose as described in the Owner’s Manual. The use
ELECTRIC SHOCK! To avoid possible electrical shock, take special care when using water with this
ELECTRIC SHOCK! Do not operate any disinfection unit if it has a damaged cord or plug, if it is
ELECTRIC SHOCK! Always unplug disinfection unit from outlet when not in use, before putting on or
CAUTION! Shut down system before servicing:
EYE PROTECTION MUST BE WORN!Never look at an operating UV light with the naked eye. The light
To guard against injury, basic safety precautions must be observed.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS AND SAFE
THESE INSTRUCTIONS
CAUTION! Denotes a potentially dangerous situation. Failure to observe this
warning may lead to minor or serious personal injury and material damage.
CAUTION! Ultraviolet light (UV-C) is harmful to eyes and skin. Use UV lamps only inside the disinfection
chamber with the appropriate protective covering. Avoid exposure to UV-C radiation.
of attachments not recommended or sold by WEDECO may cause an unsafe condition.
CAUTION! Disinfection unit must be properly installed in accordance with the Owner’s Manual and in
compliance with all applicable local and state regulations before use. Read and observe all important notices
on the disinfection unit.
CAUTION! The WEDECO DLR Series UV disinfection unit is intended for indoor use only.
equipment. Always shut off and disconnect power to the unit before:
Making repairs (We strongly recommend that a qualified individual who fully understands the Owner’s
x
Manual perform service and/or repairs.)
Cleaning
x
Replacing a UV lamp
x
malfunctioning, or if it is dropped or damaged in any way.
ELECTRIC SHOCK! The power cord of disinfection unit is equipped with a 3-prong grounding plug that
mates with a standard 3-prong grounded wall outlet to minimize the possibility of electric shock. Be sure the
outlet for the disinfection unit is wired and grounded properly.
remove the third prong from the power cord.
taking off parts, and before cleaning. Never unplug by pulling on the power cord. Always grip plug firmly
and pull straight out of the outlet.
xTurn off water supply to the UV disinfection unit.
xDisconnect all power to the UV disinfection unit.
xDrain water from the system.
will burn and irritate unprotected eyes and skin.
EYE PROTECTION MUST BE WORN! Never operate the UV lamp outside of the UV disinfection unit.
ELECTRIC SHOCK! Warning — Dangerous electric voltage. Failure to
observe this warning may lead to serious injury or death.
EYE PROTECTION MUST BE WORN!
IMPORTANT! Denotes a useful tip and other information.
Do Not under any circumstances cut or
3
Page 5
Pre-Installation Instructions
IMPORTANT
Please read before installing your Ultraviolet System
When this unit is wired in conjunction with another electrical devise you may experience a drop in voltage. It is recommended
that your Ultraviolet System NOT share a circuit with another electrical device. The maximum voltage threshold for this
system is 130V. The minimum voltage threshold for this system is 105V. Please ensure that proper voltage requirements are
meet before installing your Ultraviolet System.
Please read before installing your Ultraviolet System
IMPORTANT
Before you
begin
Perform the following pre-installation steps:
Step Action
1 Ensure that your DLR system is correct for your flow capacity (see Flow Rate Tables
in Technical Specifications.)
2 Ensure that your water supply meets water quality standards as shown in the table
below. If any of the elements exceed the recommended maximum, we strongly
suggest, at a minimum, that you install a 5-micron sediment filter as particles in the
water can reduce UV light intensity and affect performance. Contact the distributor for
additional information about testing and pretreatment equipment.
Suspended solids <5 mg/l Color None Iron 0.3 mg/l Manganese 0.05 mg/l pH 6.5 to 9.5 Hardness <120 ppm
3 Check the pressure of the water supply. The WEDECO UV system is designed to
Less than 125 psi Proceed to step 3 Greater than 125 psi Install a suitable pressure-reducing valve in
Element Recommended
maximum levels
(1mg/l = 1ppm)
Note: All models are rated for a minimum UV transmission of 90%. If your
transmission is lower, consult the distributor.
operate at pressures up to 125 psi.
If the pressure is… Then…
the water inlet pipe to the disinfection unit.
Actual
4
Fill in the following information and retain for future reference.
Unit Model No.________________ Serial No._____________________
Date Purchased:_______________ Date Installed:_________________
Water pressure (psi):___________ Water flow rate (gpm):__________
4
Page 6
5 Select a location that meets the following guidelines.
xThe unit must be installed between the cold water source and the water heater as
inlet temperature must not exceed 100
o
F. (See Figure 1 for proper installation
sequence.)
xThe disinfection unit can be installed either horizontally or vertically. (See Figure
3 for water flow direction.)
xThere must be enough clearance to remove the UV lamp and the quartz sleeve for
replacement and regular maintenance. Recommended clearance is length of unit
plus four inches. (See Figure 4 for additional clearance requirements.)
xThe unit must be within 7 feet of an 110V electrical outlet. A 7'5" cord is included
with the unit.
xThe unit must be protected from freezing. Freezing damage will void the warranty.
xThe unit should be placed where a potential leak will not cause water damage.
WEDECO is not responsible for water damage.
5
Page 7
Pre-Installation Instructions, Continued
p
Figure 1:
Installation
Sequence
Figure 2:
Installation
Planning
Figure 1 shows a typical installation sequence. Note that all items may not be
necessary for water treatment.
WEDECO
HOT WATER
HEATER
U V D ISIN F E CT IO N
UNIT
OPTIONAL EQUIPMENT
SUCH AS SOFTENER,
OR ODOR FILTER
You must determine how to run pipes in and out of your disinfection unit.
Figure 2 shows one method of installation (with chamber mounted control
box). Use this diagram to determine the materials needed for your installation.
WATER
SEDIMENT
FILTER
NOTE: PRETREA TMENT EQUIPM ENT
MUST BE INSTALLED PRIOR TO
U V D ISIN F E CT IO N U N IT
SOURCE
IMPORTANT!
Check local plumbing
codes for sizes and types of
pipes to be used.
ELECTRIC SHOCK!
Check for hidden electrical
wiring before drilling
holes.
The disinfection chamber must
be properly grounded to a
suitable electrical ground.
Check local electrical codes for
roper location. Attach ground
wire (not included) to stud and
nut located on lower area of
disinfection chamber.
ELECTRICAL
OUTLET
SHUTOFF VALVES SHOULD BE
INSTALLED BEFORE AND AFTER
THE DISINFECTION CHAMBER
UV DISINFECTION
CHAMBER
ELECTRICAL
**
CONTROL BOX
DRAIN
SHUTOFF
VALVE
MINI MUM CLEARA NCE
IS LENGTH OF UNIT
PLUS 4"
FLOW
DIRECTION
SHUTOFF
*
VALVE
OUTLET
SOLENOID POWER CORD
INLET
SHUTOFF VALVE MAY BE REQUIRED
*
TO MEET LOCAL PLUMBING CODES
CAN BE MOUNTED ON THE UNIT OR SEPARATEL Y
**
ON THE WALL. CHECK YOUR LOCAL ELECTRI CAL
OPTIONAL SOL ENOID
VALVE
CODES.
FLOW
RESTRICTOR
6
Page 8
Pre-Installation Instructions, Continued
p
Figure 3: Unit
Positioning
Figure 3 shows proper water flow for horizontal or vertical installation. Make
certain that your unit and the inlet and outlet pipes are in the right position for
either horizontal or vertical installation.
Correct Installation
IMPORTANT!
For vertical
installation, the
inlet is at the
bottom and the
outlet is near the
top of the
disinfection
chamber. For
horizontal
installation pay
careful attention to
the diagram for
flow direction.
Figure 4:
Clearance
Requirements
OUTLET
FLOW
DIRECTION
INLET
INLETINLET
DIRECTION
FLOW
OUTLETOUTLET
DIRECTION
DIRECTION
OUTLET
FLOW
INLET
FLOW
OUTLET
FLOW
DIRECTIONDIRECTION
DIRECTION
FLOW
OUTLET
INLET
INLET
INLET
INLET
OUTLET
FLOW
DIRECTION
FLOW
OUTLET
Incorrect Installation
Figure 4 provides the clearance requirements needed for proper installation of
the disinfection chamber.
ELECTRICAL
CONTROL BOX
ELECTRICAL
OUTLET
POWER CORD
(7' 5" LO N G )
The disinfection chamber must
be properly grounded to a
suitable electrical ground.
Check local electrical codes for
roper location. Attach ground
wire (not included) to stud and
nut located on lower area of
disinfection chamber.
LAMP CORD
(42" LONG )
SENSOR CORD
(42" L ON G)
MINIMUM CLEARANCE
IS L ENG TH O F U N IT
PLUS 4"
FLOW
DIRECTION
UNIT
DLR 1
DLR 2
DLR 4
DLR 744.6"
FLOW RESTRICTOR
WEDECO
UV D ISINF EC TION
CHAMBER
OUTLET
SENSOR
(DL R-M ONL Y)
INL ET
MIN. CLEARANCE
22.5"
30.4"
30.4"
MINIMUM
20.00"
LOCA TION
OPTIONAL SOLENOID
VALVE
SOLENOID POW ER CORD
(8' LO NG )
INS TAL L F LOW RE S TR ICTO R W ITH AR RO W
*
IN DIRECTION OF WATER FLOW.
FLOW
*
RESTRICTOR
7
Page 9
Installing the Disinfection Unit
Attaching unit
to wall
Follow these steps to attach WEDECO UV disinfection chamber to the wall.
Step Action Diagram
1 Install the two wall mount brackets on the
wall using the proper screws for your wall
type (screws not included).
2 Place disinfection chamber in the brackets
and secure with the wall mount bracket
straps. Use the wall mount bracket strap
screws provided to tighten the wall mount
bracket straps to the wall mount brackets.
3 The disinfection chamber must be properly
grounded prior to powering up the system.
Attach the ground wire to the stud and nut
located on the lower area of the
disinfection chamber and connect it to the
earth strap that is located at the bottom left
of the electrical box. (Grounding wire
included.)
8
Page 10
Mounting Electrical Control Box
Option A: Wall
mount
Option B:
Chamber
mount
IMPORTANT!
The electrical control box can be mounted on the wall (Option A) or on the
disinfection chamber (Option B), according to the following instructions.
Follow these steps to mount the electrical control box on the wall.
Step Action
1 Attach the optional wall mount bracket to the wall using suitable hardware for your wall
surface.
2 Position the keyhole slots on the back of the electrical control box over the tabs on the
wall mount bracket and slide into place.
Keyhole Slots
Follow these steps to mount the electrical control box on the disinfection chamber.
Step Action Diagram
1
2 Position the electrical control box on the UV
Feed the electrical control box straps through the
upper and lower recessed areas on the back of the
electrical control box.
disinfection chamber: Wrap the electrical box straps
around the chamber, push loose end through high
side of Q-Clip, and pull through to tighten.
If it is necessary to remove the electrical control box strap, lift the pawl to
release the Q-Clip. You may need to use a screwdriver to lift the pawl.
PAWL
9
Page 11
Installing the UV Lamp
CAUTION
Insert lamp in
chamber
UV lamp is very fragile. Do not handle it with bare hands. Use clean cotton
gloves or cloth when handling lamp to keep it free of dust or fingerprints. If
dust or fingerprints get on the lamp, wipe it with a clean cloth and alcohol.
Follow these steps to install the UV lamp in the disinfection chamber.
Step Action
1
Insert the lamp into the headpiece. Gently pinch the two large tabs on the
transparent lamp clip and push until the tab locks into the groove (see step 2).
2 Make sure that the transparent tab is properly snapped into the headpiece and is
not pushed down too far.
GROOVE
TRANSPARENT
LAMP CLIP
HEAD PIECE
DISINFECTION
CHAMBER
HORIZONTAL TAB
TAB PROPERLY
LOCATED IN GROOVE
TAB NOT PROPERLY
LOCATED IN GROOVE
10
Page 12
Installing the UV Lamp, Continued
A
Position GloCap
The Glo-Cap must be properly placed on the headpiece for the UV
disinfection unit to work. Follow the steps below to position the Glo-Cap.
Step Action
1 Align the tab on the Glo-Cap with the middle tab on the transparent clip.
2 Lower the Glo-Cap onto the headpiece until it clicks into place. If it does not
click into place, make sure that the tabs on the Glo-Cap are not over the raised
tabs on the headpiece. If they are, turn the Glo-Cap. When properly installed, the
Glo-Cap will not separate from the headpiece.
GLO-CAP
LIGNMENT TAB
MIDDLE
TAB
TAB
HEADPIECE TAB
11
Page 13
Pre-Start Up Sequence
Before using
the unit…
Step Action
Follow these steps before operating your WEDECO disinfection unit.
1 Check your plumbing:
xMake sure that new plumbing has no leaks.
xFlush pipes to purge soldering residue or other debris from the system.
xExpel air from the system to avoid pressure damage to the unit.
2
Before initial use of your UV system and after routine maintenance procedures, you should sanitize your
water system to ensure that no organisms are present.
Pour household bleach into your water system. If you have a filter container, fill it with bleach. If you have
no filter then introduces chlorine directly into your well. The amount of chlorine depends upon the
diameter and depth of your well. (Generally, use ½ gallon to treat an 8” diameter/80’ deep well and one
gallon for anything larger.) You may contact your State Extension Service or a water treatment specialist
for additional information.
Open hot and cold water taps throughout the house and let the water run until you detect a chlorine odor.
To ensure that the hot water heater is also purged, allow the hot water to run until the water becomes cold.
Turn off the taps and allow the water to stay in the pipeline for about six hours or overnight but not more
than 36 hours to avoid corrosion.
Open hot and cold water taps throughout the house and let the water run until the chlorine odor
disappears.
Flush the UV system for 5 minutes prior to start-up.
Plug one end of power cord into receptacle on the bottom of electrical control box, making sure plug is
pushed in completely.
IMPORTANT! Do not plug power cord into wall outlet until you begin the start-up
sequence.
12
Page 14
Start-Up Sequence
Before using
the unit…
If your unit is… Then…
DLR A
Follow the start-up procedures below.
xSlowly fill the unit with water.
xPlug power cord into wall outlet.
xWait 30 seconds. If the lamp is working, the "Power On" LED will light.
xTurn off water flow.
xSanitize your system before using your household water (see maintenance
section for instructions. Slowly fill the unit with water.
13
Page 15
Maintenance
Required
maintenance
Replacing the
lamp
Periodically, you will need to perform routine maintenance procedures on
your WEDECO UV disinfection unit. This section provides directions for:
x Replacing the lamp (every 365 days or in the event of a lamp-out alarm).
x Cleaning the quartz sleeve (as needed).
x Replacing the headpiece O-ring (every 365 days or when needed, based
The UV lamp is rated to provide 365 days of continuous use. After this time,
it must be replaced for the disinfection unit to operate effectively.
Step Action
1 Turn off the water supply to the UV disinfection unit.
2 Disconnect all power to the UV disinfection unit and wait several minutes for the lamp to
3 Drain the system: Have a bucket large enough to hold the water in the chamber, close both
4 Remove the Glo-Cap: Rotate the Glo-Cap so that the tabs line up with the raised tabs on the
5 Remove the lamp: Gently pinch together the two large tabs on the transparent clip and pull
6 Insert the new UV lamp (refer to directions for installing the UV lamp).
7 Restart your disinfection unit according to the start-up sequence for your model specifications.
8 Record the date in the maintenance log.
9 Sanitize your water system (see directions in this section).
on visual inspection).
cool.
shutoff valves, and open the drain to draw off the water.
headpiece and pull the cap away from the headpiece to remove it.
lamp assembly straight up until it is completely removed.
IMPORTANT! Lamp must be disposed of properly. Check your local regulations for
disposal of hazardous materials.
14
Page 16
Maintenance, Continued
Cleaning the
quartz sleeve,
headpiece, &
O-Ring
The quartz sleeve must be kept clean to kill bacteria effectively. Your water
quality and mineral content will determine cleaning frequency. Perform a
visual inspection after thirty (30) days of operation. If the sleeve is dirty,
shorten cleaning intervals. If the sleeve is clean, lengthen cleaning intervals.
At this time, clean the headpiece and O-Ring also.
Step Action
1 Fill bucket or other receptacle with warm, soapy water.
2 Follow Steps 1 through 5 for replacing the lamp (see previous page).
3 Unscrew the headpiece and carefully remove the quartz sleeve from the disinfection chamber.
IMPORTANT! The quartz sleeve may stick to the headpiece. Be sure to hold both pieces
carefully so they don’t separate during removal.
3 Take the headpiece and O-ring off the quartz sleeve. Clean the headpiece, O-Ring, and quartz
sleeve with a mild soap and hot water solution. If the sleeve is still not clean, use a mild acid
(citric acid or Lime-Away), then rinse with hot water.
4 Push the O-Ring a few inches down on the quartz sleeve and lower the sleeve into the
chamber.
5 Screw the headpiece onto the disinfection chamber to secure the quartz sleeve and O-Ring in
place.
6 Carefully reinstall the UV lamp and the Glo-Cap (see directions for installing the UV lamp).
7 Restart your disinfection unit according to the start-up sequence for your model specifications.
8 Record the date in the maintenance log.
9 Sanitize your water system (see directions in this section).
HEADPIECE
HEADPIECE
O-RING
QUARTZ
SLEEVE
O-RING SEAT
QUARTZ
SEAT
HEADPIECE
O-RING
15
Page 17
Maintenance, Continued
Replacing the
O-Ring
Sanitizing the
system
General maintenance for the O-Ring requires that you replace it every 365 days. If,
however, during routine cleaning of the quartz sleeve, you find the O-Ring cut,
damaged, or extremely dirty, then it should be replaced at this time. To replace the
O-Ring, follow the directions for cleaning.
Before initial use of your UV unit and after routine maintenance procedures, you
should sanitize your water system to ensure that no organisms are present.
Step Action
1 Pour household bleach into your water system. If you have a filter container, fill it
with bleach. If you have no filters then introduce chlorine directly into your well.
The amount of chlorine depends upon the diameter and depth of your well.
(Generally, use ½ gallon to treat an 8” diameter/80’ deep well and one gallon for
anything larger.) You may contact your State Extension Service or a water
treatment specialist for additional information.
2 Open hot and cold water taps throughout the house and let the water run until you
detect a chlorine odor. To ensure that the hot water heater is also purged, allow
the hot water to run until the water becomes cold.
3 Turn off the taps and allow the water to stay in the pipeline for about six hours or
overnight but not more than 36 hours to avoid corrosion.
4 Open hot and cold water taps throughout the house and let the water run until the
chlorine odor disappears.
16
Page 18
Maintenance Log
Note
Replace lamp (every
365 days)
You must perform routine maintenance in order to achieve optimum performance
levels from your WEDECO UV disinfection unit. As you perform routine
maintenance or necessary service on your unit, record the dates in the maintenance
log. The maintenance section of the Owner’s Manual provides instructions for
servicing and maintenance procedures.
Replace O-Ring (every
365 days)
Clean quartz sleeve (as
needed)
Reset lamp counter
(with lamp change)
17
Page 19
Parts List
8
7
6
5
KEY #PART #QTY.DESCRIPTION
1 *1Electrical Control Box
2 *1Disinfection Chamber
3 *1Quartz Sleeve
4 *1Ultraviolet Lamp
5AQ354921Head Piece O-Ring
6AQ365381Head Piece
7AQ366171Glo-Cap O-Ring
8AQ367991
9AQ7025761
10AQ369422
10AAQ369922
11*2
12*2
13*4
14***1
15***1
16**AQ369441
4
Glo-Cap
Sensor Assembly (
Electrical Control Box Strap
Electrical Control Box Strap Buckle
Wall Mount Bracket
Wall Mount Bracket Strap
Wall Mount Bracket Strap Screw
Flow Control
Solenoid Valve (Not available on DLR A model)
Power Cord
Contact the distributor for replacement parts
* Determined by serial number
** Not shown
not available on DLR-A model
)
3
11
13
10
12
13
9
1
11
2
13
18
12
Page 20
Alarms
Displays
The front panel of the electrical control box has the following LED displays:
LED Displays Diagram
xPOWER ON: green
x LAMP OUT: red
STATUS
LAMP ON
REPLACE LAMP
ALARM
Alarm
activation
The WEDECO UV disinfection unit has built in alarms to warn of inefficient
performance or lamp failure.
Model What Happens Cause How to Resolve
DLR-A
.
The LAMP OUT LED
x
is illuminated
continuously.
The internal ALARM
x
buzzer beeps
continuously.
Ɣ Lamp has failed due to another
problem. (See Troubleshooting
section.)
WARNING! Disinfection may
be insufficient to ensure safe
drinking water.
Replace lamp immediately. Follow
x
instructions on lamp replacement in
the manual.
19
Page 21
Troubleshooting
Determining
problem
If… Then…
The unit is leaking water
Glo-Cap is not lit or has
gone out
Poor bacterial
performance
Power fails
Display screen is blank
Unit gives faulty alarms
The troubleshooting guide gives you suggestions for resolving problems.
xEnsure that the headpiece is tight.
xVerify that inlet water pressure is not >125 psi.
xEnsure that headpiece O-ring is seated properly.
xLubricate O-ring (use food-grade silicone).
xCheck O-ring for cracks or rips. Replace if necessary.
xCheck quartz sleeve for possible cracks. If sleeve is cracked, call distributor for
replacement.
xVerify that all electrical connections are correct.
xReplace lamp. If problem is solved, resume unit operation.
xIf lamp still does not light, electrical control box may need to be replaced. Call distributor
for replacement information.
xReplace lamp if it is more than 365 days old or nearing the end of its lamp life.
xPerform routine maintenance.
xCheck water quality. If water quality has changed then you may need to install filters or
other disinfection units to ensure that water supply does not exceed recommended
maximum concentration levels (shown in Step 1 of Pre-Installation Instructions).
xVerify flow rate using the flow rate table found in the Technical Specifications at the back
of the manual.
xThe unit will restart automatically.
Note: The unit is designed for continuous operation. Never connect the unit to a timer or other
device, which will cause the unit to cycle on and off. Excessive cycling of the power will
reduce lamp life.
xEnsure that the unit is assembled and installed correctly. In the case of improper handling
or assembly during installation and/or servicing, the unit will turn off power to the lamp
and display a blank screen.
x Check for damage to the lamp filament elements, quartz sleeve, or electrode connectors.
Applying power to a unit with such damage will cause a blank display screen. Damage
may be caused from shipping, overheating the lamp by operating the unit with no water in
the chamber, introducing debris into the unit from the water source, or improper handling
or assembly during service or installation.
Note: In most cases, replacing the lamp, and/or quartz sleeve will return the unit to proper
operation. If the unit fails to resume operation, notify your distributor.
xThe ballast or control circuit may be faulty. Call distributor for replacement information.
20
Page 22
Technical Specifications: DLR Series
All prices and specifications are subject to change without notice.
Technical Description
Description The DLR Series is designed with a single low-pressure high-intensity UV lamp
centered inside a protective quartz sleeve. The disinfection chamber is either
304 or 316L stainless steel and is electro-polished with male NPT Inlet/Outlet.
The UV lamp and quartz jacket assembly are easily removable from one side
of the disinfection chamber.
UV disinfection chamber
UV lamp High output low pressure UV lamp
Control Box
Application The DLR series is engineered to disinfect clear fresh water to meet drinking
Operational capacity Clear fresh water up to 24 US GPM
Options
Flow Rate Table: Valid for water with minimum UV transmittance > 90% @ 1cm (254nm)
DLR A Series type 1 2 4
Flow rate (gpm) at UV dose of 30 mJ/cm2 at the end of lamp lifetime
Flow rate (gpm) at UV dose of 20 mJ/cm2 at the end of lamp lifetime
Flow rate (gpm) at UV dose of 16 mJ/cm2 at the end of lamp lifetime
30 mJ/cm2 = 30,000 µWs/cm
Notes: (1) Flow rates based on flow restrictor installed in line.
The DLR-AP is available in different sizes based on flow capacity. The varying technical features of the model are described below.
Model Characteristics
Features DLR-A
Effective microbiological protection
Electro-polished stainless steel disinfection chamber
High output low pressure UV lamp
High efficiency electronic ballast power supply
Lamp operation indicator
Safety lamp connector (no lamp removal without lamp shut-off)
Audible alarm plus visual alarm display (lamp failure)
Manufactured by:
WEDECO Ideal Horizons, Inc.
3520 Westinghouse Blvd.
Charlotte, NC 28273
Tel: (704) 716-7600
Fax (704) 716-7601
www.wedecouv.com
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
Ɣ
22
Page 24
Warranty
Note
FULL ONE-YEAR WARRANTY ON UV DISINFECTION UNIT: For one (1) year from date of purchase, when this
UV water disinfection unit is installed and maintained in accordance with our instructions, WEDECO will repair, free of
charge, defects in material or workmanship in this UV water disinfection unit.
FULL TEN-YEAR WARRANTY ON DISINFECTION CHAMBER: For ten (10) years from date of purchase,
WEDECO will furnish a new current model pressure vessel, free of charge, if the pressure vessel fails because of a
manufacturing defect.
FULL TWO-YEAR WARRANTY ON ELECTRICAL PARTS: For two (2) years from date of purchase, WEDECO
will provide, free of charge, parts and factory labor to repair or replace electrical parts that fail because of defects in
material or workmanship.
FULL ONE-YEAR WARRANTY ON ULTRAVIOLET LAMP: For one (1) years from date of purchase, WEDECO
will provide, free of charge, an ultraviolet lamp to replace a lamp that fails because of defects in materials or
workmanship. This does not include lamps that are broken by the consumer.
FULL ONE-YEAR WARRANTY ON EXPENDABLE ITEMS: For one (1) year from date of purchase, WEDECO
will provide, free of charge, expendable items such as quartz, view port assemblies, gaskets, flow controls, and O-rings
that fail because of defects in materials or workmanship.
Save sales slip or cancelled check for proof of original purchase date to
establish warranty period.
WEDECO ULTRAVIOLET DISINFECTION UNIT WARRANTY
This warranty is void if equipment is not installed and operated according to instructions in the Owner’s Manual. It does
not apply to damage caused by abuse, accident, neglect, freezing, fire, floods, or acts of God. This warranty is void on
any part from which the original manufacturing date code decal has been removed or made illegible. This warranty
requires the use of WEDECO Ideal Horizons authorized replacement parts. All models must be operated and maintained
in accordance with the Owner’s Manual.
This warranty shall be void if the ultraviolet system is moved from the original point of installation, if the operating
pressure exceeds 125 psi, or if the influent water temperature exceeds 100oF or goes below freezing.
All defective parts must be returned to WEDECO Ideal Horizons, Inc., for inspection and repair or replacement. Contact
the factory for a Return Goods Authorization Number prior to shipment. Defective parts must be sent prepaid freight.
WEDECO Ideal Horizons will inspect, test, and determine cause of defective component parts. WEDECO Ideal Horizons
will not be liable for any labor charges other than factory repairs. Incidental or consequential damages are not covered by
this warranty. Warranty DOES NOT cover freight costs.
The customer must order replacement parts as a standard purchase until the defective part is returned to the factory and
evaluated. The factory will determine the extent of warranty coverage and proper warranty credit to be applied.
This warranty gives you specific legal rights and you may have other rights that will vary from state to state. Some states
do not allow limitations on implied warranties or exclusion of incidental or consequential damages.
All claims must be submitted in writing to your ultraviolet equipment supplier within thirty (30) days from the discovery
of the defect. Your ultraviolet equipment supplier will correct defective parts and/or workmanship within sixty (60) days
from the time of receiving this notice.
Warranty Forms must be filled out and sent back to WEDECO Ideal Horizons for this warranty to be valid. WEDECO
Ideal Horizons, Inc will keep Warranty Forms on file.
23
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.